EPCOS B88069X5010 Surge arrester 2-electrode arrester Datasheet

Surge arrester
2-electrode arrester
Series/Type:
Ordering code:
M51-C90X
B88069X5010****
Version/Date:
Version:
Issue 08 / 2010-07-09
01
Content of header bars 1 and 2 of data sheet will be automatically entered in headers and footers! Please fill in the
table and then change the color to "white" (or invisible). This ensures that the table disappears for the customer
PDF. To update the data sheet, click on the symbol "Preview" and then "Close". Please do not alter the header or
footer when copying the content.
Identification/Classification 1:
(header 1 + top left header bar)
Surge arrester
Identification/Classification 2:
(header 2 + bottom left header bar)
2-electrode arrester
Ordering code:
(top right header bar)
B88069X5010****
Series/Type:
(top right header bar)
M51-C90X
Preliminary data (optional):
(if necessary)
Department:
PPD AB PD / PPD AB PM
Date:
Issue 08 / 2010-07-09
© EPCOS AG 2010. Reproduction, publication and dissemination of this document, enclosures hereto and the information
contained therein without EPCOS' prior express consent is prohibited.
Surge arrester
2-electrode arrester
B88069X5010****
M51-C90X
Features
ƒ
ƒ
ƒ
ƒ
ƒ
ƒ
ƒ
Small size
High current rating
Fast response time
Stable performance over life
Low capacitance
High insulation resistance
RoHS-compatible
Applications
ƒ Modem
ƒ XDSL-splitter
ƒ Data lines
ƒ Tuner
ƒ Antenna
Electrical specifications
DC spark-over voltage 1) 2)
90
± 20
V
%
< 400
< 300
V
V
< 600
< 550
V
V
5
10
5
7.5
0.5
100
A
A
kA
kA
kA
A
Insulation resistance at 50 VDC
>1
GΩ
Capacitance at 1 MHz
<1
pF
Arc voltage at 1 A
Glow to arc transition current
Glow voltage
~ 15
~ 0.8
~ 60
V
A
V
Weight
~1
g
Operation and storage temperature
-40 ... +90
°C
Climatic category (IEC 60068-1)
40/ 90/ 21
Impulse spark-over voltage
at 100 V/µs - for 99 % of measured values
- typical values of distribution
at 1 kV/µs
Service life
10 operations
1 operation
10 operations
1 operation
1 operation
300 operations
- for 99 % of measured values
- typical values of distribution
50 Hz, 1 s
50 Hz, 0.18 s (9 cycles)
8/20 µs
8/20 µs
10/350 µs
10/1000 µs
Marking, blue negative
90 YY O
90
YY
O
- Nominal voltage
- Year of production
- Non radioactive
1)
At delivery AQL 0.65 level II, DIN ISO 2859
In ionized mode
Terms in accordance with ITU-T Rec. K.12 and DIN 57845/VDE0845
2)
PPD AB PD / PPD AB PM
Please read Cautions and warnings and
Important notes at the end of this document.
Issue 08 / 2010-07-09
Page 2 of 4
Surge arrester
2-electrode arrester
B88069X5010****
M51-C90X
Dimensional drawing in mm
Ordering code and packing advice
B88069X5010S102 = 100 pcs on 5 taped stripes
B88069X5010C102 = 100 pcs in container
Cautions and warnings
ƒ
ƒ
ƒ
ƒ
Surge arresters must not be operated directly in power supply networks.
Surge arresters may become hot in case of longer periods of current stress (danger of burning).
Surge arresters may be used only within their specified values. In case of overload, the head
contacts may fail or the component may be destroyed.
Damaged surge arresters must not be re-used.
PPD AB PD / PPD AB PM
Please read Cautions and warnings and
Important notes at the end of this document.
Issue 08 / 2010-07-09
Page 3 of 4
Important notes
The following applies to all products named in this publication:
1. Some parts of this publication contain statements about the suitability of our products for
certain areas of application. These statements are based on our knowledge of typical
requirements that are often placed on our products in the areas of application concerned. We
nevertheless expressly point out that such statements cannot be regarded as binding
statements about the suitability of our products for a particular customer application. As a
rule, EPCOS is either unfamiliar with individual customer applications or less familiar with them
than the customers themselves. For these reasons, it is always ultimately incumbent on the
customer to check and decide whether an EPCOS product with the properties described in the
product specification is suitable for use in a particular customer application.
2. We also point out that in individual cases, a malfunction of electronic components or failure
before the end of their usual service life cannot be completely ruled out in the current state
of the art, even if they are operated as specified. In customer applications requiring a very high
level of operational safety and especially in customer applications in which the malfunction or
failure of an electronic component could endanger human life or health (e.g. in accident
prevention or life-saving systems), it must therefore be ensured by means of suitable design of the
customer application or other action taken by the customer (e.g. installation of protective circuitry
or redundancy) that no injury or damage is sustained by third parties in the event of malfunction or
failure of an electronic component.
3. The warnings, cautions and product-specific notes must be observed.
4. In order to satisfy certain technical requirements, some of the products described in this
publication may contain substances subject to restrictions in certain jurisdictions (e.g.
because they are classed as hazardous). Useful information on this will be found in our Material
Data Sheets on the Internet (www.epcos.com/material). Should you have any more detailed
questions, please contact our sales offices.
5. We constantly strive to improve our products. Consequently, the products described in this
publication may change from time to time. The same is true of the corresponding product
specifications. Please check therefore to what extent product descriptions and specifications
contained in this publication are still applicable before or when you place an order.
We also reserve the right to discontinue production and delivery of products. Consequently,
we cannot guarantee that all products named in this publication will always be available.
The aforementioned does not apply in the case of individual agreements deviating from the
foregoing for customer-specific products.
6. Unless otherwise agreed in individual contracts, all orders are subject to the current version of
the “General Terms of Delivery for Products and Services in the Electrical Industry”
published by the German Electrical and Electronics Industry Association (ZVEI).
7. The trade names EPCOS, BAOKE, Alu-X, CeraDiode, CSMP, CSSP, CTVS, DeltaCap, DigiSiMic,
DSSP, FormFit, MiniBlue, MiniCell, MKD, MKK, MLSC, MotorCap, PCC, PhaseCap, PhaseCube,
PhaseMod, PhiCap, SIFERRIT, SIFI, SIKOREL, SilverCap, SIMDAD, SiMic, SIMID, SineFormer,
SIOV, SIP5D, SIP5K, ThermoFuse, WindCap are trademarks registered or pending in Europe
and in other countries. Further information will be found on the Internet at
www.epcos.com/trademarks.
Page 4 of 4
Similar pages