BTCPOWER BAO60-UAC-30

BTCPower
BAO10 ~ 60 Series
Broadband TelCom Power, Inc.
TM
Redefining “Current” Limits In Power Conversion
10 ~ 60W Open Frame AC-DC Power Modules
•
•
•
•
•
•
•
Universal Input 90-264 Vac
PCB Mountable
Efficiency to 75%.
Industry Standard Pin Out
100 % full load burn-in test
ISO-9001 certified manufacturer
Short circuit / overload / over voltage
protection
• Approvals: UL / TUV / CE
Specifications
Input voltage range…………………………………… 90-264 Vac
Input frequency………….……………………………… 47 – 63 Hz
Inrush current…………………………………………… Cold start, 25A / 155Vac, 50A / 230Vac max.
Output voltage….………………………………………… Refer to below table
Initial Accuracy ………………………………………….. ±1.0% max.
Temperature Coefficient ……………………………….. ±0.05% / ºC
Ripple & Noise, 20Mhz BW ……………………………. 50mVp-p, max @ 3.3/5Vo; 1%p-p,max @
others output voltage modules
Hold-up time ¹ ………………………………………….. 8-16ms typ.
Short circuit protection……………...…………………… Continuous
Line regulation ² .…………………………………….…. ±0.05% max.
Load regulation ³ ………………………………………… ±1.0% max.
Efficiency ………..…..…………………………………… Refer to below table
Isolation Voltage (Input/Output) ……………………… 4242 Vac
Operating temp. range ………………………………… 0 ºC – 45 ºC
Storage temp. range ………………………..…………. -40 ºC – +100 ºC
Cooling…………………………………………………… Free air convection
Note:
1.
2.
3.
Measured at Vin = 115 Vac, Full load
Measured from high line to low line
Measured from full load to 10% load
BTCPower
TM
Part Number Selection
Part No
Output
Tolerance
Ripple
Efficiency
BAO10-UAC-3.3
3.3V, 2.5A
+/ - 1 %
50 mV
65%
BAO10—UAC-5
5V, 2.0A
+/ - 1 %
50 mV
70%
9V, 1.11A
+/ - 1 %
90 mV
72%
BAO10-UAC-12
BAO10-UAC-9
12V, 0.83A
+/ - 1 %
120 mV
75%
BAO10-UAC-15
15V, 0.67A
+/ - 1 %
150 mV
75%
BAO10-UAC-24
24V, 0.417A
+/ - 1 %
240 mV
78%
BAO15-UAC-3.3
3.3V, 3.0 A
+/ - 1 %
50 mV
70%
BAO15-UAC-5
5V, 4.4 A
+/ - 1 %
50 mV
70%
BAO15-UAC-9
9V, 2.44A
+/ - 1 %
90 mV
77%
BAO15-UAC-12
12V, 1.8 A
+/ - 1 %
120 mV
80%
BAO15-UAC-15
15V, 1.4 A
+/ - 1 %
150 mV
80%
BAO15-UAC-24
24V, 0.92A
+/ - 1 %
240 mV
82%
BAO20-UAC-3.3
3.3V, 4.4A
+/ - 1 %
50 mV
70%
BAO20-UAC-5
5V, 4.4A
+/ - 1 %
50 mV
73%
BAO20-UAC-9
9V, 2.44A
+/ - 1 %
90 mV
77%
BAO20-UAC-12
12V, 1.8A
+/ - 1 %
120 mV
80%
BAO20-UAC-15
15V, 1.4A
+/ - 1 %
150 mV
80%
BAO20-UAC-24
24V, 0.92A
+/ - 1 %
240 mV
82%
BAO40-UAC-3.3
3.3V, 6 A
+/ - 1 %
50 mV
74%
BAO40- UAC-5
5V, 6 A
+/ - 1 %
50 mV
78%
9V, 4.45A
+/ - 1 %
90 mV
82%
BAO40- UAC-12
BAO40- UAC-9
12V, 3.34A
+/ - 1 %
120 mV
84%
BAO40- UAC-15
15V, 2.67A
+/ - 1 %
150 mV
85%
+/ - 1 %
240 mV
86%
BAO40- UAC-24
24V, 1.67A
BAO40- UAC-30
30V, 1.33A
+/ - 1 %
300 mV
86%
BAO40- UAC-36
36V, 1.11A
+/ - 1 %
360 mV
87%
BAO40- UAC-48
48V, 0.834A
+/ - 1 %
480 mV
88%
BAO60- UAC-3.3
3.3V, 8 A
+/ - 1 %
50 mV
74%
BAO60- UAC-5
5V, 8 A
+/ - 1 %
50 mV
78%
BAO60- UAC-9
9V, 6.67A
+/ - 1 %
90 mV
82%
BAO60- UAC-12
12V, 5 A
+/ - 1 %
120 mV
84%
BAO60- UAC-15
15V, 4 A
+/ - 1 %
150 mV
85%
BAO60- UAC-24
24V, 2.5 A
+/ - 1 %
240 mV
86%
BAO60- UAC-30
30V, 2 A
+/ - 1 %
300 mV
86%
BAO60- UAC-36
36V, 1.67A
+/ - 1 %
360 mV
87%
+/ - 1 %
480 mV
88%
BAO60- UAC-48
48V, 1.25A
Note: BAO40 and BAO60 series , the output voltage can be 0.1V interval.
Broadband TelCom Power, Inc. – 1719 S. Grand Avenue, Santa Ana, CA 92705 U.S.A. Pg. 2.
Tel.: 714-259-4888 • Fax: 714-259-0840 • www.btcpower.com • Email: [email protected] AC/DC BAO10-60 PB Ver1 8-7-03