Sensortechnics BCD-4000-904 Optical blood component detector Datasheet

BCD Series
Optical blood component detectors
FEATURES
· Non-invasive optical technology
· Micro-controller based integral
circuitry
· Immunity to ambient light
· High accuracy and reliability
· Detects blood per ANSI/AAMI
RD5:2003
SPECIFICATIONS
ELECTRICAL CONNECTION
Maximum ratings
Supply voltage (VS)
5 VDC
(optional 6...24 VDC)
Supply current
typ. 150 mA
Temperature limits
Storage
Operating
-20 ... 85 °C
5 ... 60 °C
Humidity limits
0 - 95 %RH
(non-condensing)
Sensor
1
2
3
4
5
6
7
8
9
10
11
12
13
14
Brown
Red
Orange
Yellow
Green
Blue
Violet
Gray
White
Return
Power in
CAL input
CAL output
Blood output
Tube detect output
Liquid detect output
NC
NC
NC
Red intensity analog output
Blue intensity analog output
NC
NC
Note: Set CAL input (Pin 3) momentary high
to begin calibration. CAL output (Pin 4)
will be high if calibration is complete.
November 2007 / 307
1/3
www.sensortechnics.com
BCD Series
Optical blood component detectors
PERFORMANCE CHARACTERISTICS
Characteristics
Min.
Typ.
Max.
Logic low voltage
0.6
VS-0.7
Logic high voltage
CAL input min. width1
Response time
50
Units
V
ms
Calibration2
15
Blood detect3
s
500
Tube detect
100
Liquid detect
200
ms
Notes:
1. The minimum width for the CAL input to initiate a calibration cycle. Pulses shorter than this may be ignored
2. The maximum time to perform the tube calibration cycle.
3. The maximum time to detect blood levels rising above the limit or blood levels falling below the limit.
OUTLINE DRAWING
0.42
(10.67)
Slot for 0.250 (6.35) tube
1.25
(31.75)
1.50
(38.10)
0.75
(19.05)
1.25
(31.75)
Threaded holes
4-40 x 0.22 (5.59)
1.00
(25.40)
Connector Molex 51021-1400
all dimensions in inches (mm)
November 2007 / 307
2/3
www.sensortechnics.com
BCD Series
Optical blood component detectors
ORDERING INFORMATION
Series
Options
Example:
Notes:
BCD
BCD -
Electrical
1 5 V input,
logic output
2
6...24 V input,
logic output
3
5 V input,
analog and
logic output
4
6...24 V input,
analog and
logic output
1
Options
Design type
000 Standard
(threshold AAMI),
28 inch leads,
no tube detection,
no liquid detection
8
for rigid tubing
9
for soft tubing
000
8
-
Tubing siz e
04 1/4 inch O.D.
04
Sensortechnics is asking customers for a sample of their tubing. The sensor will then be
calibrated for exactly this tubing. For proper function the sensor should only be used
with the tubing which was sent to Sensortechnics!
Custom specific modifications are widely available. Please contact your nearest
Sensortechnics sales office for further information.