DIN Rail Power Supplies_Australia cata.qxd

AC/DC OPEN FRAME & ENCLOSED
Delta PMC 24V Series
1 5 0 W A T T S - P A N E L M O U N T P O W E R S U P P LY
FEATURES
•
•
•
•
•
•
Universal AC input voltage without power de-rating
Full corrosion resistant Aluminium chassis
Conforms to harmonic current IEC/EN 61000-3-2, Class A
High MTBF > 700,000 hrs per Telcordia SR-332
Safety approval according to IEC/EN/UL 60950-1 (ITE standard)
and EMI to EN 55022, Class B
Also available: IP20 and Front Face connectors
SPECIFICATIONS
OUTPUT
PMC24V1500W1AA
MECHANICAL
Output Voltage
24V
Case Cover
Aluminium
Output Voltage Range
22-28V
Dimensions (L x W x D)
178 x 97 x 38 mm
Output Current
6.25A
Unit Weight
0.48 kg
Output Power
150W
Cooling System
Convection
Line Regulation
< 0.5% typ. (@ 85-264Vac input, 100% load)
MTBF 2)
> 700,000 hrs
Load Regulation
< 1% typ. (@ 85-264Vac input, 0-100% load)
PARD (20MHz)
< 100mVpp
Operating Temperature
-10°C to +70°C
Hold-up Time
> 15ms @ 115Vac,
> 80ms @ 230Vac
Storage Temperature
-25°C to +85°C
Power De-rating
> 50°C (2.5% / °C)
Operating Humidity
< 95% RH (Non-Condensing)
Operating Altitude
3,000m
INPUT
Input Voltage Range
85-264Vac (DC input range 125-375Vdc)
Input Frequency
47-63Hz
< 3.10A @ 115Vac,
Input Current
< 2.00A @ 230Vac
> 87.0% @ 115Vac,
Efficiency 1) at 100% Load
> 88.0% @ 230Vac
< 60A @ 115Vac,
Max Inrush Current
< 120A @ 230Vac
Leakage Current
< 1mA @ 240Vac
ENVIRONMENTAL
NOTES:
1) Efficiency: O/P 100% load, Ta: 25°C at Vertical Mounting Orientation
2) MTBF as per Telcordia SR-332 (Confidential level: 90%, I/P: 115Vac,
O/P: 100% load) at Vertical Mounting Orientation
3) All parameters are specified at 25°C ambient unless otherwise noted
MECHANICAL DRAWINGS
384