MIAR03 SERIES - MINMAX Technology

®
MIAR03 SERIES
DC/DC CONVERTER 3W, DIP-Package
FEATURES
►Industrial Standard DIP-24 Package
►Fully Regulated Output Voltage
►I/O Isolation 1500 VDC
►Operating Ambient Temp. Range -40°C to +85°C
►Short Circuit Protection
►Designed-in Conducted EMI meets EN55022 Class A & FCC Level A
►UL/cUL/IEC/EN 60950-1 Safety Approval
PRODUCT OVERVIEW
The MIAR03 series is a range of isolated 3W DC/DC converter modules featuring fully regulated output voltages and narrow input voltage ranges.Excellent
efficiency allow an operating temperature range of -40°C to +85°C (with Derating).The product comes in a DIP-24 Plastic package with alternative pinout
which makes these converters also a perfect replacement for the popular S200R series.These DC/DC converters offer a very economical solution for many
cost critical applications.
Model Selection Guide
Model
Number
MIAR03-05S05
MIAR03-05S12
MIAR03-05S15
MIAR03-05D12
MIAR03-05D15
MIAR03-12S05
MIAR03-12S12
MIAR03-12S15
MIAR03-12D12
MIAR03-12D15
MIAR03-24S05
MIAR03-24S12
MIAR03-24S15
MIAR03-24D12
MIAR03-24D15
Input
Voltage
(Range)
Output
Voltage
VDC
VDC
5
12
15
±12
±15
5
12
15
±12
±15
5
12
15
±12
±15
5 ±10%
12 ±10%
24 ±10%
Output Current
Input Current
Max. capacitive
Load
Max.
@Max. Load
@No Load
mA
600
250
200
±125
±100
600
250
200
±125
±100
600
250
200
±125
±100
mA(typ.)
857
769
769
769
769
338
313
313
309
305
167
156
156
154
152
mA(typ.)
Efficiency
(typ.)
@Max. Load
μF
470
100
100
100#
100#
470
100
100
100#
100#
470
100
100
100#
100#
90
45
22
%
70
78
78
78
78
74
80
80
81
82
75
80
80
81
82
# For each output
Input Specifications
Parameter
Model
Input Voltage Range
Input Surge Voltage (1 sec. max.)
Max.
5V Input Models
4.5
5
5.5
10.8
12
13.2
24V Input Models
21.6
24
26.4
5V Input Models
-0.7
---
7.5
12V Input Models
-0.7
---
15
24V Input Models
-0.7
---
30
---
---
2000
All Models
Conducted EMI
Unit
VDC
mW
Internal Pi Type
Compliance to EN 55022,class A and FCC part 15,class A
E-mail:[email protected]
2015/07/31 REV:2
Typ.
12V Input Models
Short Circuit Input Power
Input Filter
Min.
Tel:886-6-2923150
Page 1 of 4
®
MIAR03 SERIES
DC/DC CONVERTER 3W, DIP-Package
Output Specifications
Parameter
Conditions
Output Voltage Setting Accuracy
Min.
Typ.
Max.
Unit
---
---
±2.0
%Vnom.
Output Voltage Balance
Dual Output, Balanced Loads
Vin=Min. to Max. @Full Load
-----
±1.0
±0.2
±3.0
±0.5
%
Line Regulation
Load Regulation
Io=10% to 100%
---
±0.2
±0.5
%
60
mV P-P
Minimum.Load
%
No minimum Load Requirement
Ripple & Noise
0-20 MHz Bandwidth
---
Short Circuit Protection
---
Continuous, Automatic Recovery
General Specifications
Parameter
I/O Isolation Voltage
Conditions
Min.
Typ.
Max.
Unit
60 Seconds
1500
---
---
VDC
1 Second
1800
---
---
VDC
I/O Isolation Resistance
500 VDC
1000
---
---
MΩ
I/O Isolation Capacitance
100KHz, 1V
---
300
---
pF
---
300
---
KHz
Switching Frequency
MTBF(calculated)
MIL-HDBK-217F@25℃, Ground Benign
Safety Approvals
700,000
Hours
UL/cUL 60950-1 recognition (CSA certificate), IEC/EN 60950-1(CB-report)
Environmental Specifications
Parameter
Operating Ambient Temperature Range
(See Power Derating Curve)
Conditions
Min.
Max.
Natural Convection
-40
+85
Unit
℃
℃
Case Temperature
---
+95
Storage Temperature Range
-50
+125
℃
Humidity (non condensing)
---
95
% rel. H
260
℃
Cooling
Natural Convection
Lead Temperature
(1.5mm from case for 10Sec.)
---
Power Derating Curve
Output Power (%)
100
80
Natural
Convection
20LFM
60
400LFM
40
20
0
~
-40
0
20
40
60
Ambient Temperature C
E-mail:[email protected]
2015/07/31 REV:2
Tel:886-6-2923150
Page 2 of 4
80
100 110
®
MIAR03 SERIES
DC/DC CONVERTER 3W, DIP-Package
Notes
1
Specifications typical at Ta=+25℃, resistive load, nominal input voltage and rated output current unless otherwise noted.
2
We recommend to protect the converter by a slow blow fuse in the input supply line.
3
Other input and output voltage may be available, please contact factory.
4
That “natural convection” is about 20LFM but is not equal to still air (0 LFM).
5
Specifications are subject to change without notice.
Package Specifications
Pin Connections
Pin
Single Output
4.5
[0.18]
10.2
[0.40]
Mechanical Dimensions
0.50 [0.02]
3
10
11
12
Bottom View
24
23
15
22
14
20.3 [0.80]
2
15.22 [0.60]
1
Dual Output
1
+Vin
+Vin
2
NC
-Vout
3
NC
Common
10
-Vout
Common
11
+Vout
+Vout
12
-Vin
-Vin
13
-Vin
-Vin
14
+Vout
+Vout
15
-Vout
Common
22
NC
Common
23
NC
-Vout
24
+Vin
+Vin
13
17.78 [0.70]
2x2.54
[2x0.10]
31.8 [1.25]
2x2.54
[2x0.10]
2.0
[0.08]
2.54
[0.10]
NC: No Connection
►All dimensions in mm (inches)
►Tolerance: X.X±0.5 (X.XX±0.02)
X.XX±0.25 ( X.XXX±0.01)
► Pin diameter  0.5 ±0.05 (0.02±0.002)
Physical Characteristics
Case Size
:
31.8x20.3x10.2 mm (1.25x0.80x0.40 inches)
Case Material
:
Non-Conductive Black Plastic (flammability to UL 94V-0 rated)
Pin Material
:
Copper Alloy with Gold Plate Over Nickel Subplate
Weight
:
12.4g
E-mail:[email protected]
2015/07/31 REV:2
Tel:886-6-2923150
Page 3 of 4
®
MIAR03 SERIES
DC/DC CONVERTER 3W, DIP-Package
Test Setup
Peak-to-Peak Output Noise Measurement Test
Use a Cout 0.33μF ceramic capacitor.
Scope measurement should be made by using a BNC socket, measurement bandwidth is 0-20 MHz. Position the load between 50 mm and 75 mm from the DC/DC
Converter.
+Vin
+Out
Copper Strip
Single Output
DC / DC
Converter
-Vin
Cout
-Out
Scope
Resistive
Load
Copper Strip
+Vin
+Out
Copper Strip
Dual Output
DC / DC
Converter
Com.
Copper Strip
-Vin
-Out
Copper Strip
Scope
Cout
Resistive
Load
Cout
Scope
Technical Notes
Maximum Capacitive Load
The MIAR03 series has limitation of maximum connected capacitance at the output. The power module may be operated in current limiting mode during start-up,
affecting the ramp-up and the startup time. The maximum capacitance can be found in the data sheet.
Input Source Impedance
The power module should be connected to a low ac-impedance input source. Highly inductive source impedances can affect the stability of the power module.
In applications where power is supplied over long lines and output loading is high, it may be necessary to use a capacitor at the input to ensure startup.
Capacitor mounted close to the power module helps ensure stability of the unit, it is recommended to use a good quality low Equivalent Series Resistance (ESR <
1.0Ω at 100 KHz) capacitor of a 4.7μF for the 5V input devices and a 2.2μF for the 12V and 24V devices.
+
DC Power
Source
+Vin
+
+Out
DC / DC
Converter
Load
Cin
-
-Vin
-Out
Output Ripple Reduction
A good quality low ESR capacitor placed as close as practicable across the load will give the best ripple and noise performance. To reduce output ripple, it is
recommended to use 1.5μF capacitors at the output.
+
+Vin
-
+Out
Single Output
DC / DC
Converter
DC Power
Source
-Vin
+
Cout
Load
-Out
+Vin
DC Power
Source
-
+Out
Dual Output
DC / DC Com.
Converter
-Vin
-Out
Cout
Load
Load
Cout
Thermal Considerations
Many conditions affect the thermal performance of the power module, such as orientation, airflow over the module and board spacing. To avoid exceeding the
maximum temperature rating of the components inside the power module, the case temperature must be kept below 95℃. The derating curves are determined
from measurements obtained in a test setup.
Position of air velocity
probe and thermocouple
15mm / 0.6in
50mm / 2in
Air Flow
DUT
18, Sin Sin Road, An-Ping Industrial District, Tainan 702, Taiwan
Tel: 886-6-2923150 Fax: 886-6-2923149 E-mail: [email protected]
Minmax Technology Co., Ltd.
2015/07/31 REV:2
Page 4 of 4