2 ZE/ZV/ZV2/XE/XV/XV2 - OMRON Industrial Automation

Enclosed Switches
ZE/ZV/ZV2/XE/XV/XV2
CSM_ZE_ZV_ZV2_XE_XV_XV2_DS_E_3_1
General-purpose Enclosed
Switches with High Breaking
Capacity and High Durability
• Z General-purpose Basic Switches are built into ZE, ZV,
and ZV2 Switches. They provided high durability and high
breaking capacity.
• X Basic Switches with magnetic blowout are built into XE,
XV, and XV2 Switches. DC models have also been added
to the series.
• Three mounting methods (side, base, and diagonal side)
and many types of actuator are available.
• Terminals face the front when the cover is removed for
easy connection.
• Switches with ground terminals have CE marking.
• Approved by UL, CSA, and CCC (Chinese standard).
(Ask your OMRON representative for information on
approved models.)
For the most recent information on models that have been certified for
safety standards, refer to your OMRON website.
Be sure to read Safety Precautions on page 8 to 9 and
Safety Precautions for All Limit Switches.
Model Number Structure
Model Number Legend (Not all combinations are possible. Ask your OMRON representative for details.)
@@-@-2@
(1) (2) (3)
(4)
(1) Built-in Switch
Z
X
: SPDT (AC)
: SPDT (DC)
(2) Mounting Direction
E : Side mounting
V : Base mounting
V2 : Diagonal side mounting
(3) Actuator
Q
Q22
Q21
QA2
QA277
N
N22
N21
NA2
NA277
: Plunger
: Roller plunger
: Crossroller plunger
: Roller arm lever
: One-way action roller arm lever
: Sealed plunger
: Sealed roller plunger (ZE, ZV, ZV2 only)
: Sealed crossroller plunger (ZE, ZV, ZV2 only)
: Sealed roller arm lever
: Sealed one-way action roller arm lever
(4) Conduit/Ground Terminal *
None
G1
G
SG1
YG1
S
Y
: G 1/2/without ground terminal
: G 1/2/with ground terminal
: Pg13.5/with ground terminal
: 1/2-14NPSM/with ground terminal
: M20/with ground terminal
: 1/2-14NPSM/without ground terminal
: M20/without ground terminal
* Consult with your OMRON representative concerning availability, pricing, and delivery of conduit sizes and ground terminal specifications other than those on standard
models.
1
ZE/ZV/ZV2/XE/XV/XV2
Ordering Information
Side mounting
Base mounting
Diagonal side mounting
Mounting
Actuator
Approved
standards
Model
AC
ZE-Q-2
Model
UL
CSA
●
●
ZV-Q-2
●
●
ZV-Q22-2
Approved
standards
Model
UL
CSA
●
●
ZV2-Q-2
●
●
ZV2-Q22-2
Approved
standards
UL
CSA
●
●
●
●
●
●
●
●
●
●
●
●
Plunger
DC
XE-Q-2
AC
ZE-Q22-2
XV-Q-2
XV2-Q-2
DC
XE-Q22-2
AC
ZE-Q21-2
DC
XE-Q21-2
AC
ZE-QA2-2
DC
XE-QA2-2
AC
ZE-QA277-2
DC
XE-QA277-2
AC
ZE-N-2
DC
XE-N-2
Sealed roller plunger
AC
ZE-N22-2
●
●
ZV-N22-2
●
●
ZV2-N22-2
●
●
Sealed crossroller
plunger
AC
ZE-N21-2
●
●
ZV-N21-2
●
●
ZV2-N21-2
●
●
AC
ZE-NA2-2
●
●
ZV-NA2-2
●
●
ZV2-NA2-2
●
●
DC
XE-NA2-2
AC
ZE-NA277-2
●
●
DC
XE-NA277-2
Roller plunger
General
purpose
XV-Q22-2
●
●
ZV-Q21-2
XV2-Q22-2
●
●
ZV2-Q21-2
Crossroller plunger
XV-Q21-2
●
●
ZV-QA2-2
--●
●
ZV2-QA2-2
Roller arm lever
One-way action roller
arm lever
XV-QA2-2
●
●
XV2-QA2-2
---
ZV2-QA277-2
--●
●
ZV-N-2
--●
●
ZV2-N-2
Sealed plunger
Sealed
(Booted)
XV-N-2
XV2-N-2
Sealed roller arm lever
One-way action
sealed roller arm lever
XV-NA2-2
●
●
ZV-NA277-2
XV2-NA2-2
●
●
---
ZV2-NA277-2
XV2-NA277-2
Note: 1. The diagonal side mounting model feature improved sealing property, improved mounting strength through use of M5 screws, increased stability in seating with
large mounting width (31 x 75 mm) and permit coupling of a number of Switch units.
2. Ask your OMRON representative for information on models with ground terminals.
Specifications
Approved Standards
Agency
Standard
UL
CSA
File No.
UL508
E76675
CSA C22.2 No.14
LR45746
GB14048.5
2003010303077623
CCC (CQC)
Note: 1. Models XE, XV, and XV2 are not approved by UL, CSA, and CCC.
2. Ask your OMRON representative for information on approved models.
Ratings
Non-inductive load (A)
Model
Rated
voltage
Resistive load
NC
ZE-@
ZV-@
ZV2-@
XE-@
XV-@
XV2-@
NO
125 VAC
250 VAC
480 VAC
15
15
10
125 VDC
250 VDC
0.5
0.25
8 VDC
14 VDC
30 VDC
125 VDC
250 VDC
10
10
10
10
3
Inductive load (A)
Lamp load
NC
NO
3
2.5
1.5
1.5
1.25
0.75
0.5
0.25
3
3
3
3
1.5
Inductive load
NC
NO
15
15
6
Motor load
NC
NO
5
3
1.5
2.5
1.5
0.75
0.05
0.03
1.5
1.5
1.5
1.5
0.75
10
10
10
7.5
2
Inrush
current
NC
30 A max.
NO
15 A max.
0.05
0.03
10
10
10
6
1.5
5
5
5
2
2
2.5
2.5
2.5
2.5
1.5
Note: 1. The above figures are for standard currents.
2. Inductive loads have a power factor of 0.4 min.
(AC) and a time constant of 7 ms max. (DC).
3. Lamp load has an inrush current of 10 times
the steadystate current.
4. Motor load has an inrush current of 6 times the
steady-state current.
2
ZE/ZV/ZV2/XE/XV/XV2
Approved Standard Ratings
Characteristics
UL/CSA
Degree of protection
Model
Rated voltage
Current
ZE
125 VAC
250 VAC
480 VAC
15 A
15 A
15 A
125 VDC
250 VDC
0.5 A
0.25 A
Horsepower
Mechanical
Durability
*2
1/8HP
1/4HP
Electrical
--Operating speed
CCC (GB14048.5)
Mechanical
Electrical
Rated frequency
Insulation resistance
Contact resistance
Terminal temperature rise
Between terminals
of the same polarity
Between currentcarrying metal
Dielectric
part and ground
strength
Between each
terminal and
non-current-carrying metal part
Vibration
Malfunction
resistance
Destruction
Shock
resistance
Malfunction
*3
Operating
frequency
Applicable category and ratings
AC-12 10 A/250 VAC
Ambient operating temperature
Ambient operating humidity
Weight
IP65*1
Z@: 10,000,000 operations min.
X@: 1,000,000 operations min.
Z@: 500,000 operations min., for 15 A,
250 VAC resistive load
X@: 100,000 operations min., for 10 A,
125 VDC resistive load
Plunger type: 0.01 mm/s to 0.5 m/s
Lever type: 0.02 mm/s to 0.5 m/s
120 operations/min
20 operations/min
50/60 Hz
100 MΩ min. (at 500 VDC)
15 mΩ max. (initial value)
50°C max.
1,000 VAC, 50/60 Hz for 1 min
Z@: 2,000 VAC, 50/60 Hz for 1 min
X@: 1,500 VAC, 50/60 Hz for 1 min
Z@: 2,000 VAC, 50/60 Hz for 1 min
X@: 1,500 VAC, 50/60 Hz for 1 min
10 to 55 Hz, 1.5-mm double amplitude*3
1,000m/s2 max.
100 m/s2 max.*4
50 m/s2 max.*5
−10°C to +80°C (with no icing)
General-purpose type: 35% to 85%RH
Sealed type: 35% to 95%RH
Approx. 260 to 280 g
Note: The above figures are initial values.
*1. IP65 for @-N models and IP60 for @-Q models.
*2. The values are calculated at an operating temperature of +5°C to +35°C, and an
operating humidity of 40% to 70%RH. Contact your OMRON sales
representative for more detailed information on other operating environments.
*3. At the operation limit positions.
*4. Only for plunger, sealed plunger, roller arm lever, and sealed roller arm
lever.
*5. Only for crossroller plunger, sealed crossroller plunger, roller plunger, and
sealed roller plunger.
Engineering Data
Electrical Durability
XE (L/R = 0)
Durability (x 104 operations)
Durability (x 104 operations)
ZE (cosφ = 1)
Operating frequency:
20 operations/min
OT: Full stroke
1,000
125 VAC
500
250 VAC
Operating frequency:
20 operations/min
OT: Full stroke
200
125 VAC
100
70
250 VAC
50
100
480 VAC
50
0
2
4
6
8
10
12
14 16
Switching current (A)
1
2
3
5
10
Switching current (A)
XE (L/R = 7 ms)
Durability (x 104 operations)
Durability (x 104 operations)
ZE (cosφ = 0.4)
0
Operating frequency:
20 operations/min
OT: Full stroke
1,000
125 VAC
500
250 VAC
480 VAC
Operating frequency:
20 operations/min
OT: Full stroke
100
70
125 VAC
50
30
250 VAC
20
100
50
0
2
4
6
8
10
12
14
16
Switching current (A)
0
1
2
3
5
10
Switching current (A)
3
ZE/ZV/ZV2/XE/XV/XV2
Structure and Nomenclature
Structure
Contact Form
ZE-NA2-2
COM
NC
NO
Pin plunger
Note: With the XE-@, XV-@, and XV2-@@, be sure to connect COM to the
+ terminal.
Tightening band
Rubber cap (CR)
Case
Separator
Built-in switch
Terminal
Conduit
opening
Cover
Seal rubber (NBR)
Note: The conduit thread indication has been changed from "PF1/2" to "G1/2"
accompanying the JIS B 0202 revision. This changes applies only to the
indication; thread sizes and pitches have not been affected.
Dimensions and Operating Characteristics
(Unit: mm)
Side Mounting Models
Plunger
ZE-Q-2
XE-Q-2
12R *
Two, M4
(length: 45)
JIS B0202 G1/2
Effective thread:
4 threads min.
17
PT
Roller Plunger
ZE-Q22-2
XE-Q22-2
Two, M4
(length: 45)
OP
19
OP
25.5
23
2.1±0.1
25.4±0.3
86
2.1±0.1
25.4±0.3
24
25.4±0.12
86
* Stainless steel plunger
24
25.4±0.12
* Stainless steel roller
12.7 dia. × 4.8 *
PT
JIS B0202 G1/2
Effective thread:
4 threads min.
17
Two, M4
(length: 45)
PT
19
25.5
23
Crossroller Plunger
ZE-Q21-2
XE-Q21-2
12.7 dia. × 4.8 *
JIS B0202 G1/2
Effective thread:
4 threads min.
17
19.1 dia. × 7.9 *1
Roller Arm Lever
ZE-QA2-2
XE-QA2-2
(23.1)
JIS B0202 G1/2
Effective thread:
4 threads min.
PT
17
Two, M4
(length: 45)
OP
*2
39.7
44±0.8
19.3
19
19
2.1±0.1
25.4±0.3
86
25.4±0.12
25.5
23
25.5
23
2.1±0.1
25.4±0.3
24
86
25.4±0.12
24
*1. Stainless sintered roller
*2. Adjustable between 0° and 225°
* Stainless steel roller
Note: 1. Unless otherwise specified, a tolerance of ±0.4 mm applies to all dimensions.
2. The diagrams shown the Switches with two, M4 screws (length: 45) attached. (The screws are provided.)
Operating
characteristics
Model
Operating force
Release force
Pretravel
Over Travel
Movement Differential
OF
RF min.
PT max.
OT min.
MD max.
Operating Position
OP
ZE-Q-2
XE-Q-2
ZE-Q22-2
XE-Q22-2
ZE-Q21-2
XE-Q21-2
ZE-QA2-2
XE-QA2-2
2.45 to 3.43 N
1.12 N
0.4 mm
5.5 mm
0.05 mm
5.00 N max.
1.12 N
0.9 mm
5.5 mm
0.47 mm
2.45 to 3.43 N
1.12 N
0.5 mm
3.6 mm
0.05 mm
5.00 N max.
1.12 N
0.9 mm
3.6 mm
0.47 mm
2.45 to 3.43 N
1.12 N
0.5 mm
3.6 mm
0.05 mm
5.00 N max.
1.12 N
0.9 mm
3.6 mm
0.47 mm
5.59 N max.
1.67 N
4 mm
6 mm
0.4 mm
6.47 N max.
1.67 N
6 mm
5.5 mm
0.72 mm
38.2±0.8 mm
49.7±1 mm
49.7±1 mm
---
4
ZE/ZV/ZV2/XE/XV/XV2
One-way Action Roller Arm Lever
ZE-QA277-2
18.7 dia. × 9 *1
XE-QA277-2
Operate in this
direction only
39.7
(40)
17.4R
JIS B0202 G1/2
Effective thread:
4 threads min.
17
Two, M4
(length: 45)
Sealed Plunger
ZE-N-2
XE-N-2
*2
12R *
PT
2.1±0.1
86
86
*1. Stainless sintered alloy roller
*2. Adjustable between 0° and 225°
Two, M4
(length: 45)
2.1±0.1
25.4±0.3
24
25.4±0.12
25.5
23
25.5
25.4±0.3
OP
19
19
23
Sealed Roller Plunger
ZE-N22-2
17
Two, M4
(length: 45)
44±0.8
19.3
PT
JIS B0202 G1/2
Effective thread:
4 threads min.
25.4±0.12
24
* Stainless steel plunger
Sealed Crossroller Plunger
ZE-N21-2
12.7 dia. × 4.8 *
JIS B0202 G1/2
Effective thread:
4 threads min.
17
12.7 dia. × 4.8 *
PT
OP
PT
JIS B0202 G1/2
Effective thread:
4 threads min.
17
Two, M4
(length: 45)
OP
19
19
25.5
23
2.1±0.1
25.4±0.3
86
25.4±0.12
2.1±0.1
25.4±0.3
24
86
* Stainless steel roller
Sealed Roller Arm Lever
ZE-NA2-2
XE-NA2-2
25.5
23
24
* Stainless steel roller
19.1 dia. × 7.9 *1
39.7
One-way Action Sealed Roller Arm Lever
18.7 dia. × 9 *1
ZE-NA277-2
XE-NA277-2
*2
(40)
17.4R
(23.1)
JIS B0202 G1/2
Effective thread:
4 threads min.
17
Two, M4
(length: 45)
25.4±0.12
JIS B0202 G1/2
Effective thread:
4 threads min.
PT
53.4±0.8
19.3
Two, M4
(length: 45)
86
25.4±0.12
53.4±0.8
19.3
19
2.1±0.1
25.4±0.3
24
86
*1. Stainless sintered alloy roller
*2. Adjustable between 0° and 225°
19
25.5
23
2.1±0.1
25.4±0.3
PT
17
25.5
23
Operate in this
direction only
39.7
*2
25.4±0.12
24
*1. Stainless steel roller
*2. Adjustable between 0° and 225°
Note: 1. Unless otherwise specified, a tolerance of ±0.4 mm applies to all dimensions.
2. The diagrams shown the Switches with two, M4 screws (length: 45) attached. (The screws are provided.)
OF max.
RF min.
PT max.
OT min.
MD max.
ZE-QA277-2
XE-QA277-2
ZE-N-2
XE-N-2
ZE-N22-2
5.59 N
1.67 N
4 mm
6 mm
0.4 mm
6.47 N
1.67 N
6 mm
5.5 mm
0.72 mm
7.85 N
2.35 N
2 mm
5 mm
0.1 mm
10.20 N
2.35 N
3 mm
4 mm
0.47 mm
4.90 N
0.98 N
1 mm
3.5 mm
0.12 mm
OP
OF max.
RF min.
PT max.
OT min.
MD max.
OP
---
45.8±0.8 mm
49.7±0.8 mm
ZE-N21-2
ZE-NA2-2
XE-NA2-2
ZE-NA277-2
XE-NA277-2
4.90 N
0.98 N
1 mm
3.5 mm
0.12 mm
6.28 N
2.26 N
5 mm
6 mm
0.4 mm
7.26 N
2.26 N
6 mm
5.5 mm
0.72 mm
6.28 N
2.26 N
5 mm
6 mm
0.4 mm
7.26 N
2.26 N
6 mm
5.5 mm
0.72 mm
49.7±0.8 mm
---
---
5
ZE/ZV/ZV2/XE/XV/XV2
Base Mounting/Diagonal Side Mounting Models
The diagrams show the base-mounted model (ZV-@ or XV-@) on top and the diagonal side-mounted model (ZV2-@ or XV2-@) on bottom.
The flange on base-mounted models is shown with dotted lines.
Plunger
ZV(2)-Q-2
XV(2)-Q-2
Roller Plunger
ZV(2)-Q22-2
XV(2)-Q22-2
t = 3 (ZV-Q-2/XV-Q-2 flange)
53R
t = 3 (ZV-Q22-2/XV-Q22-2 flange)
53R
41.3±0.2
54
41.3±0.2
10.5±0.3
Two, 4.3±0.2 dia.
12R *1
JIS B0202 G1/2
Effective
thread: 4
threads min.
10.5±0.3
Two, 4.3±0.2 dia.
36.6
17
36.6
12.7 dia. × 4.8 *1
JIS B0202 G1/2
Effective
thread: 4 threads min.
PT
26.1
PT
26.1
(see note 2)
17
(see note 1)
5
54
5
OP
31±0.2
OP
31±0.2
23
23
3
3
*2
75±0.2
+0.2
5.5
25.4±0.3 Two, 5.4 0 dia.
86
holes
*1. Stainless steel plunger
*2. Only the ZV2-Q-2 and XV2-Q-2 incorporate
mounting holes.
25.4±0.3
*2
Two, 5.4 +0.2
0 dia.
holes
75±0.2
5.5
86
*1. Stainless steel roller
*2. Only the ZV2-Q22-2 and XV2-Q22-2
incorporate mounting holes.
Crossroller Plunger
ZV(2)-Q21-2
XV-Q21-2
Roller Arm Lever
ZV(2)-QA2-2
XV(2)-QA2-2
t = 3 (ZV-QA2-2/XV-QA2-2 flange)
t = 3 (ZV-Q21-2/XV-Q21-2 flange)
53R
53R
41.3±0.2 54
41.3±0.2
54
10.5±0.3
Two, 4.3±0.2 dia.
12.7 dia.
Two, 4.3±0.2 dia.
4.8 *1
JIS B0202 G1/2
Effective
thread: 4 threads min.
19.1 dia. × 7.9 *1
JIS B0202
G1/2
Effective
23.1 max.
thread: 4
threads min.
PT
17
19.3
PT
26.1
(see note 3)
17
39.7
*2
30±0.8
5
5
OP
31±0.2
31±0.2
69.5±0.8
23
23
3
3
*2
+0.2
25.4±0.3 Two, 5.4 0 dia.
holes
10.5±0.3
36.6
36.6
75±0.2
86
25.4±0.3
5.5
*3
Two, 5.4 +0.2
0 dia.
holes
75±0.2
5.5
86
*1. Stainless sintered roller
*2. Adjustment between 0° to 225°.
*3. Only the ZV2-QA2-2 and XV2-QA2-2 incorporate mounting holes.
*1. Stainless steel roller
*2. Only the ZV2-Q21-2 incorporate mounting holes.
Note: Unless otherwise specified, a tolerance of ±0.4 mm applies to all dimensions.
ZV-Q-2
ZV2-Q-2
OF
RF min.
PT max.
OT min.
MD max.
OP
2.45 to 3.43 N
1.12 N
0.4 mm
5.5 mm
0.05 mm
XV-Q-2
XV2-Q-2
5.00 N max.
1.12 N
0.9 mm
5.5 mm
0.47 mm
63.7±0.8 mm (see note 1)
(ZV-Q-2, XV-Q-2)
ZV-Q22-2
ZV2-Q22-2
XV-Q22-2
XV2-Q22-2
ZV-Q21-2
ZV2-Q21-2
2.45 to 3.43 N
1.12 N
0.5 mm
3.6 mm
0.05 mm
5.00 N max.
1.12 N
0.9 mm
3.6 mm
0.47 mm
2.45 to 3.43 N
1.12 N
0.5 mm
3.6 mm
0.05 mm
75.2±0.8 mm (see note 2)
(ZV-Q22-2, XV-Q21-2)
XV-Q21-2
ZV-QA2-2
ZV2-QA2-2
XV-QA2-2
XV2-QA2-2
5.00 N max.
1.12 N
0.9 mm
3.6 mm
0.47 mm
5.59 N max.
1.67 N
4 mm
6 mm
0.4 mm
6.47 N max.
1.67 N
6 mm
5.5 mm
0.72 mm
75.2±0.8 mm (see note 3)
(ZV-Q22-2, XV-Q21-2)
---
Note: 1. OP for ZV2-Q-2 and XV2-Q-2 is 24.2 ±0.8 mm.
2. OP for ZV2-Q22-2 and XV2-Q22-2 is 35.7 ±1 mm.
3. OP for ZV2-Q21-2 is 35.7 ±0.8 mm.
6
ZE/ZV/ZV2/XE/XV/XV2
One-way Action Roller Arm Lever
ZV2-QA277-2
Sealed Plunger
ZV(2)-N-2
XV(2)-N-2
t=3 (ZV-QA277-2 flanges)
53R
18.7 dia.
9 *1
41.3±0.2
54
Two, 4.3±0.2 dia. holes
41.3±0.2
54
10.6±0.3
10.6±0.3
36.6
PT
17
53R
Two, 4.3±0.2 dia. holes
Operates in this
direction only
*2
39.7
(40)
R17.4
JIS B0202 G1/2
Effective
thread: 4
threads min.
t = 3 (ZV-N-2/XV-N-2 flange)
5
PT
26.1
12CR *1 JIS B0202 G1/2
Effective
thread: 4 threads min.
30±0.8
19.3
36.6
(see note 1)
17
69.5±0.8
5
OP
31±0.2
31±0.2
23
23
3
*3
+0.2
25.4±0.3 Two, 5.4 0 dia.
holes
3
75±0.2
*2
+0.2
25.4±0.3 Two, 5.4 0 dia.
holes
5.5
86
*1. Stainless steel roller
*2. Adjustment between 0° to 225°.
*3. Only the ZV2-QA277-2 incorporate mounting holes
Sealed Roller Plunger
ZV(2)-N22-2
53R
t = 3 (ZV-N21-2 flange)
53R
41.3±0.2
54
10.6±0.3
36.6
Two, 4.3±0.2 dia. holes
12.7 dia. × 4.8 *1
JIS B0202
G1/2 Effective
thread: 4 threads min.
12.7 dia. × 4.8 *1
JIS B0202 G1/2
Effective
thread: 4 threads min.
17
PT
(see note 2)
17
41.3±0.2
54
Two, 4.3±0.2 dia. holes
26.1
5
5.5
86
*1. Stainless steel plunger
*2. Only the ZV2-N-2 and XV2-N-2 incorporate mounting holes.
Sealed Crossroller Plunger
ZV(2)-N21-2
t = 3 (ZV-N22-2 flange)
75±0.2
10.6±0.3
36.6
PT
26.1
(see note 3)
5
OP
31±0.2
OP
31±0.2
23
23
3
3
*2
25.4±0.3 Two, 5.4 +0.2 dia.
0
holes
75±0.2
*2
25.4±0.3 Two, 5.4 +0.2
0 dia.
holes
5.5
86
*1. Stainless steel roller
*2. Only the ZV2-N22-2 incorporate mounting holes.
75±0.2
86
5.5
*1. Stainless steel roller
*2. Only the ZV2-N21-2 incorporate mounting holes.
Note: Unless otherwise specified, a tolerance of ±0.4 mm applies to all dimensions.
OF max.
RF min.
PT max.
OT min.
MD max.
OP
ZV2-QA277-2
ZV-N-2
ZV2-N-2
XV-N-2
XV2-N-2
ZV-N22-2
ZV2-N22-2
ZV-N21-2
ZV2-N21-2
5.59 N
1.67 N
4 mm
6 mm
0.4 mm
7.85 N
2.35 N
2 mm
5 mm
0.1 mm
10.20 N
2.35 N
3 mm
4 mm
0.47 mm
4.90 N
0.98 N
1 mm
3.5 mm
0.12 mm
4.90 N
0.98 N
1 mm
3.5 mm
0.12 mm
75.2±0.8 mm
(see note 2)
(ZV-N22-2)
75.2±0.8 mm
(see note 3)
(ZV-N21-2)
---
71.4±0.8 mm (see note 1)
(ZV-N-2, XV-N-2)
Note: 1. OP for ZV2-N-2 and XV2-N-2 is 31.9 ±0.8 mm.
2. OP for ZV2-N22-2 is 35.7 ±0.8 mm.
3. OP for ZV2-N21-2 is 35.7 ±0.8 mm.
7
ZE/ZV/ZV2/XE/XV/XV2
Sealed Roller Arm Lever
ZV(2)-NA2-2
XV(2)-NA2-2
One-way Action Sealed Roller Arm Lever
ZV(2)-NA277-2
XV2-NA277-2
t=3 (ZV-NA277-2 flanges)
t=3 (ZV-NA2-2/XV-NA2-2 flanges)
53R
53R
19.1 dia. × 9 *1
Two, 4.3±0.2 dia.
18.7 dia.
10.6±0.3
Two, 4.3±0.2 dia. holes
(40)
17.4R
*2
JIS B0202
G1/2
Effective
thread: 4
threads min.
PT
39.7
Operates in this
direction only
*2
PT
17
39.5±0.8
19.3
19.3
39.5±0.8
5
5
79±0.8
79±0.8
31±0.2
31±0.2
23
54
10.6±0.3
36.6
(23.1)
17
9 *1
36.6
39.7
JIS B0202
G1/2
Effective
thread: 4
threads min.
41.3±0.2
41.3±0.2 54
23
3
3
*3
75±0.2
+0.2
5.5
25.4±0.3 Two, 5.4 0 dia.
86
holes
*1. Stainless steel roller
*2. Adjustment between 0° to 225°.
*3. Only the ZV2-NA277-2 and XV2-NA277-2 incorporate
mounting holes.
*3
75±0.2
+0.2
5.5
25.4±0.3 Two, 5.4 0 dia.
86
holes
*1. Stainless sintered alloy roller
*2. Adjustment between 0° to 225°.
*3. Only the ZV2-NA2-2 and XV2-NA2-2 incorporate mounting holes.
Note: Unless otherwise specified, a tolerance of ±0.4 mm applies to all dimensions.
OF max.
RF min.
PT max.
OT min.
MD max.
ZV-NA2-2
ZV2-NA2-2
XV-NA2-2
XV2-NA2-2
6.28 N
2.26 N
5 mm
6 mm
0.4 mm
7.26 N
2.26 N
6 mm
5.5 mm
0.72 mm
ZV-NA277-2
ZV2-NA277-2
6.28 N
2.26 N
5 mm
6 mm
0.4 mm
XV2-NA277-2
7.26 N
2.26 N
6 mm
5.5 mm
0.72 mm
Safety Precautions
Refer to Safety Precautions for All Limit Switches.
Precautions for Correct Use
Operating Environment
• Seal material may deteriorate if a Switch is used outdoor or where
subject to special cutting oils, solvents, or chemicals. Always
appraise performance under actual application conditions and set
suitable maintenance and replacement periods.
• Be sure to protect part A with grease in order to maintain the
mechanical durability and performance of the Limit Switch. The use
of molybdenum disulfide grease is recommended.
• Install Switches where they will not be directly subject to cutting
chips, dust, or dirt. The Actuator and Switch must also be protected
from the accumulation of cutting chips or sludge.
Not Suitable
Suitable
• Constantly subjecting a Switch to vibration or shock can result in
wear, which can lead to contact interference with contacts,
operation failure, reduced durability, and other problems.
Excessive vibration or shock can lead to false contact operation or
damage. Install Switches in locations not subject to shock and
vibration and in orientations that will not produce resonance.
• The Switches have physical contacts. Using them in environments
containing silicon gas will result in the formation of silicon oxide
(SiO2) due to arc energy. If silicon oxide accumulates on the
contacts, contact interference can occur. If silicon oil, silicon filling
agents, silicon cables, or other silicon products are present near the
Switch, suppress arcing with contact protective circuits (surge
killers) or remove the source of silicon gas.
8
ZE/ZV/ZV2/XE/XV/XV2
Mounting
Mounting
• With the Roller Lever-type Enclosed Switches, the roller arm has
been temporarily tightened prior to shipment, so that its position
may be adjusted later. When mounting the Switch, be sure to retighten the roller arm so as to prevent it from becoming loose during
operation.
• To adequately maintain the seals at the mounting screw section on
the side of the Enclosed Switch, insert each O-ring correctly and
secure it with the lock nut.
• To provide the Switch with improved sealing property, use of the SC
Connector is recommended. Refer to Limit Switch Connectors for
details on SC Connectors.
• When routing wires into the conduit opening, be sure that cuttings
and other foreign matter do not enter the Switch.
Mounting Holes
Side Mounting
Bottom Mounting
Two, 4.3 dia.
mounting holes or
M4 screw holes
Two, 4.3 dia.
mounting holes or
M4 screw holes
25.4±0.1
41.3±0.15
Side Diagonal Mounting
Two, 5.4 dia.
mounting holes or
M5 screw holes
31±0.1
Appropriate Tightening Torque
A loose screw may result in a malfunction. Be sure to tighten each
screw to the proper tightening torque as shown below.
No.
Type
Appropriate tightening torque
1
Cover mounting screw
1.18 to 1.37 N·m
2
Switch mounting screw*1
1.18 to 1.37 N·m
3
Switch mounting screw*2
4.90 to 5.88 N·m
4
Switch terminal screw
(M4 screws)
0.78 to 1.18 N·m
5
Roller arm mounting nut
4.90 to 5.88 N·m
*1. This torque range applies to side mounting or bottom mounting. (M4 screws)
*2. This torque range applies to diagonal side mounting. (M5 Allen-head bolt)
75±0.1
Operation
• Operating method, shape of cam or dog, operating frequency, and
the overtravel (OT) have significant effect on the service life and
precision of the Limit Switch. Make sure that the shape of the cam
is smooth enough.
• Check that OT has a sufficient margin. The actual OT should be
rated OT x 0.7 to 1.
Dedicated Wrench
1. The roller arm can be set freely within a range of 225° after
loosening the nut.
2. The roller arm mounting bracket can be set in any direction after
loosening the nut.
▲
• Make sure that the nut is free of foreign substances when the nut is
loosened.
• A dedicated wrench is provided separately.
Model
SUPANA FOR ZE
9
Terms and Conditions Agreement
Read and understand this catalog.
Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you
have any questions or comments.
Warranties.
(a) Exclusive Warranty. Omron’s exclusive warranty is that the Products will be free from defects in materials and workmanship
for a period of twelve months from the date of sale by Omron (or such other period expressed in writing by Omron). Omron
disclaims all other warranties, express or implied.
(b) Limitations. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, ABOUT
NON-INFRINGEMENT, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE OF THE PRODUCTS. BUYER
ACKNOWLEDGES THAT IT ALONE HAS DETERMINED THAT THE
PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE.
Omron further disclaims all warranties and responsibility of any type for claims or expenses based on infringement by the
Products or otherwise of any intellectual property right. (c) Buyer Remedy. Omron’s sole obligation hereunder shall be, at
Omron’s election, to (i) replace (in the form originally shipped with Buyer responsible for labor charges for removal or
replacement thereof) the non-complying Product, (ii) repair the non-complying Product, or (iii) repay or credit Buyer an amount
equal to the purchase price of the non-complying Product; provided that in no event shall Omron be responsible for warranty,
repair, indemnity or any other claims or expenses regarding the Products unless Omron’s analysis confirms that the Products
were properly handled, stored, installed and maintained and not subject to contamination, abuse, misuse or inappropriate
modification. Return of any Products by Buyer must be approved in writing by Omron before shipment. Omron Companies shall
not be liable for the suitability or unsuitability or the results from the use of Products in combination with any electrical or
electronic components, circuits, system assemblies or any other materials or substances or environments. Any advice,
recommendations or information given orally or in writing, are not to be construed as an amendment or addition to the above
warranty.
See http://www.omron.com/global/ or contact your Omron representative for published information.
Limitation on Liability; Etc.
OMRON COMPANIES SHALL NOT BE LIABLE FOR SPECIAL, INDIRECT, INCIDENTAL, OR CONSEQUENTIAL DAMAGES,
LOSS OF PROFITS OR PRODUCTION OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS,
WHETHER SUCH CLAIM IS BASED IN CONTRACT, WARRANTY, NEGLIGENCE OR STRICT LIABILITY.
Further, in no event shall liability of Omron Companies exceed the individual price of the Product on which liability is asserted.
Suitability of Use.
Omron Companies shall not be responsible for conformity with any standards, codes or regulations which apply to the
combination of the Product in the Buyer’s application or use of the Product. At Buyer’s request, Omron will provide applicable
third party certification documents identifying ratings and limitations of use which apply to the Product. This information by itself
is not sufficient for a complete determination of the suitability of the Product in combination with the end product, machine,
system, or other application or use. Buyer shall be solely responsible for determining appropriateness of the particular Product
with respect to Buyer’s application, product or system. Buyer shall take application responsibility in all cases.
NEVER USE THE PRODUCT FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY OR IN LARGE
QUANTITIES WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS,
AND THAT THE OMRON PRODUCT(S) IS PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE
OVERALL EQUIPMENT OR SYSTEM.
Programmable Products.
Omron Companies shall not be responsible for the user’s programming of a programmable Product, or any consequence
thereof.
Performance Data.
Data presented in Omron Company websites, catalogs and other materials is provided as a guide for the user in determining
suitability and does not constitute a warranty. It may represent the result of Omron’s test conditions, and the user must correlate
it to actual application requirements. Actual performance is subject to the Omron’s Warranty and Limitations of Liability.
Change in Specifications.
Product specifications and accessories may be changed at any time based on improvements and other reasons. It is our
practice to change part numbers when published ratings or features are changed, or when significant construction changes are
made. However, some specifications of the Product may be changed without any notice. When in doubt, special part numbers
may be assigned to fix or establish key specifications for your application. Please consult with your Omron’s representative at
any time to confirm actual specifications of purchased Product.
Errors and Omissions.
Information presented by Omron Companies has been checked and is believed to be accurate; however, no responsibility is
assumed for clerical, typographical or proofreading errors or omissions.
2014.2
In the interest of product improvement, specifications are subject to change without notice.
OMRON Corporation
Industrial Automation Company
http://www.ia.omron.com/
(c)Copyright OMRON Corporation 2014 All Right Reserved.