MIL314 IP67 Industrial Ethernet Switch Military-Rated

Sixnet Military Series
a
business
D ATA S H E E T
MIL314 IP67 Industrial Ethernet Switch
Military-Rated Gigabit Industrial Connectivity
Red Lion’s Sixnet MIL314 has 12 Gigabit (10/100/1000) plus 2 x 10G (10,000 Mbps, fiber) ports.
This Layer 3 managed industrial Ethernet switch features military-style D38999 connectors and
link speeds ranging from 10Mb/s to 10Gb/s. With an ultra-rugged case, protected circuitry and
advanced software, this switch offers an ideal Commercial Off-The-Shelf (COTS) military solution for
battlefield communications, combat vehicles and avionics shipboard. It can also be used with industrial
applications that require hardened switches.
APPLICATION SCENARIO
PRODUCT HIGHLIGHTS
Layer 3 Ethernet switch increases
• multi-service
network performance
IPv4
and
IPv6
management
•
6 rated package protects
• IP67/NEMA
against dust, water, oil, debris
•
Driver Vision Enhancement
Acoustic Gun Fire Detection
Cameras
Remote Weapon
Mission Computer
Radio Kits
and more
High-performance switch rated for
MIL-STD-810F, MIL-STD-461F and
MIL-STD-1275D
MIL-DTL-38999
• Military-rated
Series III connectors protect against
vibration, shock, water and more
• Tough corrosion-proof aluminum case
APPLICATIONS
• Industrial outdoors
• Marine and maritime
• Transportation
• Military in-vehicle (per COTS)
• Aerospace
CONNECT. MONITOR. CONTROL.
GPS Receiver
MIL314
MIL314 Layer 3 IP67 Industrial Ethernet Switch
Military-Rated Gigabit Industrial Connectivity
ENHANCED SECURITY
Red Lion’s Sixnet MIL314 provides enhanced
security features for connectivity and access
control, including ACLs, authentication and
port-level security with IEEE 802.1X. Access
Control Lists (ACLs) can be used to restrict
access to sensitive network resources
by denying packets based on L2/L3/L4
headers. SSH and RADIUS authentication
protect data communications and ensure
data privacy. IEEE 802.1X port-based
access control ensures dynamic, port-based
security and user authentication for network
access. IP source guard prevents a malicious
user from spoofing or taking over another
user’s IP address by creating a binding table
between client’s IP and MAC address, port
and VLAN.
ADVANCED ROUTING
Red Lion’s Sixnet MIL314 supports
hardware-based IPv6 and IPv4 routing
for maximum performance. The switches
provide a seamless migration path from IPv4
to IPv6 for future network upgrades and
investment protection. Advanced routing
protocols, such as RIP and OSPF, provide
dynamic routing by exchanging routing
information with other Layer 3 switches
or routers. Multicast routing is supported
under independent multicast protocols,
including PIM-DM and PIM-SM.
COMPREHENSIVE QoS
Red Lion’s Sixnet MIL314 offers advance
QoS for marking, classification and
scheduling to deliver best-in-class
performance for data, voice and video traffic
at wire speed. Eight egress queues per port
enable differentiated management of up to
eight traffic types across the stack. Traffic
is prioritized according to 802.1p, DSCP,
IP precedence and TCP/UDP port number
to provide optimal performance for realtime applications. Weighted Round Robin
(WRR) and strict priority ensure differential
prioritization of packet flows and avoid
congestion of ingress and egress queues.
With bidirectional rate-limiting, per port or
traffic class, the MIL314 preserves network
bandwidth and allows full control of network
resources.
CONNECT. MONITOR. CONTROL.
FEATURES
Layer 2
• Spanning Tree Protocol (STP per IEEE
802.1D) plus
– IEEE 802.1w Rapid Spanning Tree Protocol
(RSTP)
– IEEE 802.1s Multiple Spanning Tree
Protocol (MSTP)
– Loopback detection
– Auto edge port
– BPDU filter/guard
• Virtual Local Area Network (VLAN)
– IP subnet based VLAN
– Private VLAN isolated
– Private VLAN
– GVRP/GARP
– 802.1v protocol
– Voice VLAN
– VLAN translation
– IPv6 VLANs
– VLAN trunking
• Jumbo Frame: 9K
• IGMP Snooping v1/v2/v3
• Select Q-in-Q
Layer 3
• Host table: 8K
• Route table: 8K
• Static route table: 512
• Multicast table: 1K
• Unicast routing
– Static unicast routes
– RIP v1/v2
– OSPF
– BGP
• Multicast routing
– PIM-DM
– PIM-SM
– IGMP v1/v2/v3
– IGMP v3 proxy
• IP redundancy
• Proxy ARP
• UDP Helper
Ethernet Performance
• Ethernet Ports:
– 12 Gigabit 10/100/1000 Mbps (copper)
– 2 x 10G 1,000 Mbps (fiber)
• Switching capacity: 128 Gbps/176 Gbps
• Forwarding Rate: 95.2 Mpps/130.9 Mpps
• MAC Address Table Size: 16K
• Packet Buffer Size: 2 MB
Security
• Port security
• IP Source Guard
• Supports IEEE 802.1X port-based and
MAC-based access control
• IP filter configuration for management
interface (SNMP, Telnet, Web)
• RADIUS authentication
• Access Control List
• SSH v2
• HTTPS/SSL
• MAC filter
• Dynamic ARP Inspection
• Link detection package protection
Management
• Switch Management
– CLI via console port or Telnet
– Web management
– SNMP v1, v2c, v3
– IGMP snooping (v1/v2)
• Firmware and Configuration:
– CLI via console port or Telnet
– Web management
– SNMP v1, v2c, v3
– IGMP snooping (v1/v2)
• Supports RMON (groups 1, 2, 3 and 9)
• Supports BOOTP, DHCP for IP address
assignment
• DHCP Snooping
• DHCP option 66, 67
• Supports SNTP
• Supports event/error log, system log
• Cable diagnostics
• ATC traffic control
• Delay reload
• sFlow
• CPU Process Utilization
• Cable Diagnostic
• IP Clustering
• Port Mirroring
QoS
• Priority Queues: 8 hardware
queues per port
• Traffic classification based on
IEEE 802.1p CoS, IP Precedence,
DSCP, TCP/UDP port number,
ACL and marking
• DiffServ
• Supports WRR and strict priority
• Port rate limiting
IPv6
• IPv4/IPv6 Dual Protocol Stack
• IPv6 Address Types: Unicast, Multicast
• ICMPv6
• ICMPv6 Redirect
• IPv6 Path MTU Discovery
• IPv6 Neighbor Discovery
• SNMP over IPv6
• HTTP over IPv6
• SSH over IPv6
• Support IPv6 Telnet
• Support IPv6 DNS Resolver
• Support IPv6 syslog
• Support IPv6 SNTP
• Support IPv6 TFTP
• Remote IPv6 ping
• Ping over IPv6
• Trace route over IPv6
• IPv6 DHCP relay
• sFlow over IPv6
• IPv6 ACL
• IPv6 DiffServ
• PIM-DMv6
• PIM-SMv6
• MVRv6
MIL314
SPECIFICATIONS
SNMP & Ethernet Standards
• Ethernet, Fast Ethernet, Gigabit Ethernet
• Full-duplex flow control
• IEEE 802.3-2005
• IEEE 802.3ae 10 Gigabit Ethernet
• IEEE 802.3D Spanning Tree Protocol
• IEEE 802.1w Rapid Spanning Tree Protocol
• IEEE 802.1s Multiple Spanning Tree Protocol
• IEEE 802.1Q Virtual LAN
• IEEE 802.1X IEEE8021-PAE-MIB
• RFC 1907 SNMPv2-MIB (MIB-II)
• RFC 2011 IP-MIB (MIB-II)
• RFC 2012 TCP-MIB (MIB-II)
• RFC 2013 UDP-MIB (MIB-II)
• RFC 1493 Bridge MIB
• RFC 2863 IF-MIB
• RFC 2819 RMON MIB
• RFC 2618 RADIUS MIB
• RFC 2665 Etherlike MIB
• RFC 2737 Entity MIB
• RFC 2674 P-bridge, Q-bridge
• V-Bridge MIB
• RFC 3036 MAU MIB
• RFC 1612 DNS Reslover MIB
• RFC 3411 SNMP Framework
• RFC 3412 SNMP MPD MIB
• RFC 3413 SNMP Target MIB, SNMP Notify MIB
• RFC 3415 SNMP View-Based ACM MIB
• SNMP Trap Supported:
• RFC 1215, 1907, 2863, 1493, 1757, 2819
• Private MIB
Power Input
• Input voltage range: 18-36 VDC (continuous)
• Input power: 40 W (estimated max. under full load)
• Reverse polarity protection
• Exceeds MIL-STD-1275 for power protection
• Surge protection: 100 volts for 1 second
• Transient protection: 15,000 watts peak
• Spike protection: 5,000 watts (10x for 10 uS) or 250 volts
(50x for 100 uS)
Physical
• Dimensions (L x W x H): 13x8.5x4.25”
• Weight (including caps): 12 lbs
• IP67 dust, oil and water-tight package protection
• LED indicators: port, uplink, system, diagnostic
• Tough corrosion proof aluminum case
• Conductive cooling — no moving parts
MECHANICAL DRAWINGS
Gig Ports
2
Warranty
• 5 years on design and manufacturing defects
Vent
Console
10G
3
4
10G
5
6
Environmental & EMC
• Operating temperature: -40 to +75° C
(cold startup at -40° C)
• Storage temperature: -40 to +85° C
• Humidity: 5 to 95% RH (non-condensing
• Vibration: IEC 68-2-36, IEC 68-2-6
• Shock: IEC 68-2-29
• Drop: IEC-68-2-32
• Vent plug for high-altitude operation
• ISO/IEC 8802-3 CSMA/CD
• FCC part 15/ICES-003; EN61000-6-4,-2
• MIL-STD-461F for EMC performance (see table)
• MIL-STD-810F for environmental performance (see table)
• MIL-STD-1275D for power protection (see table)
• MTBF per MIL-HNDBK-217F2 - TBD
Recommended Interface Plugs
• 1G Ethernet Plug: Aero AE90-365-BN9-9PN
• Power Plug: D38999/26WA98SA
• RS232 Plug: D38999/26WA35PA
• Contact distributor for mating connectors
1
13.0"
[33.02cm]
7
8
9
10
11
12
Power
8.5"
[21.59cm]
4.25"
[10.81cm]
3.24"
[8.24cm]
13.0"
[33.02cm]
All specifications are subject to change. Contact Red Lion to learn more
MIL314 Layer 3 IP67 Industrial Ethernet Switch
Military-Rated Gigabit Industrial Connectivity
EMI & EMC
Test
Conducted Emissions
Conducted Emissions
Radiated Emissions
Conducted Susceptibility
Conducted Susceptibility
Conducted Susceptibility
Conducted Susceptibility
Standard
MIL-ST-461F
MIL-ST-461F
MIL-ST-461F
MIL-ST-461F
MIL-ST-461F
MIL-ST-461F
MIL-ST-461F
Radiated Susceptibility
Radiated Susceptibility
Ripple Test
Spike Test (Imported)
Spike Test (Exported)
Surge Test
MIL-ST-461F
MIL-ST-461F
MIL-STD-1275D
MIL-STD-1275D
MIL-STD-1275D
MIL-STD-1275D
Specification
CD101: Power Leads, 30Hz to 10Hz
CE102: Power Leads, 10 kHz to 10 MHz
RE102: Electric Field, 2 MHz to 18 GHz
CS101: Power Leads, 30 Hz to 150 kHz
CS114: Bulk Cable Injection, 10 kHz to 200 MHz
CS115: Bulk Cable Injection, Impulse Excitation
CS116: Damped Sinusoidal Transients, Cables and
Power Leads, 10 kHz to 100 MHz
RS101: Electric Field, 30 Hz to 100 kHz
RS103: Electric Field, 2 MHz to 40 GHz (50V/m)
2 V Peak and 7 V Peak Ripple Test
+/- 250 Volt Imported Spike Test
Voltage Spike Exported from the EUT
40 V and 100 V Surges
Standard
MIL-STD-810F
MIL-STD-810F
MIL-STD-810F
MIL-STD-810F
MIL-STD-810F
MIL-STD-810F
MIL-STD-810F
MIL-STD-810F
MIL-STD-810F
MIL-STD-810F
MIL-STD-810F
MIL-STD-810F
Specification
Methods 501.4 and 502.4: Operating Temperature
Method 503.4: Temperature Shock
Method 507.4: Humidity
Method 500.4: Elevation
Method 516.5: Functional Shock
Method 514.5, Proc. 1: General Vibration
Paragraph 4.10 Table II: Steam and Water Jet
Method 512.4: Leakage (Immersion)
Method 509.4
Method 510.4 Proc. 1
Method 511.4
Method 513.5 Proc. 1,2,3
About Red Lion
As the global experts in
communication, monitoring
and control for industrial
automation, Red Lion has been
delivering innovative solutions
to customers for forty years.
Our award-winning technology
enables companies worldwide
to gain real-time data visibility
that drives productivity. Product
brands include Red Lion, Sixnet
and N-Tron. With headquarters in
York, Pennsylvania, the company
has offices across the Americas,
Asia-Pacific and Europe. Red Lion
is a Spectris company.
ENVIRONMENTAL
Test
Operating Temperature
Temperature Shock
Humidity
Elevation
Functional Shock
General Vibration
Steam and Water Jet
Leakage (Immersion)
Salt and Fog
Sand and Dust
Explosive Atmosphere
Acceleration Test
For more information,
visit www.redlion.net/sixnet,
call +1 (518) 877-5173 or
email [email protected]
ORDER GUIDE
Part Number
MIL314-XX*
ET-CAT6M-XCG
ET-MILPWR-C2
ET-MIL232-C2NU
Description
14-port IP67 managed L3 Ethernet switch
12 copper Gig ports plus 2 x 10G multimode or singlemode fiber
Cordset, 1G Ethernet plug to RJ45, x=meters
Cordset, power plug to leads, 2 meters
Cordset, military-style plug to 232, 2 meters
Note: See separate datasheet for cable specs. Contact Sixnet for other cordset and cable options.
*M (multimode fiber), S (singlemode fiber) 10 Gigabit speed
** Contact Sixnet for fiber options
www.redlion.net/sixnet
a
business
+1 (518) 877-5173 | [email protected]
CONNECT. MONITOR. CONTROL.
© 2012 Red Lion Controls. All Rights Reserved. AUG2012