ZD24CC Series - Teledyne Relays

ZD24CC Series
500mA, 80 Vdc Optically Isolated
Short-Circuit Protected with Trip Status
Part Number
Description
ZD24CC*
500mA, 80 Vdc short-circuit protected
up to 60 Vdc, solid-state relay for
through-hole mounting
SZD24CC*
500mA, 80 Vdc short-circuit protected
up to 60 Vdc, solid-state relay for
surface mount
*No suffix: Room temperatureelectrical testing only
W suffix: load conditioning, temperature cycling and 25°C parametric testing
T suffix: load conditioning, temperature cycling, burn-in and 3-temperature
parametric testing
ELECTRICAL SPECIFICATIONS
(–55°C to +105°C ambient temperature
unless otherwise specified)
INPUT (CONTROL) SPECIFICATIONS
• Trip status
• Low off-state leakage
Max
Units
Input Current
8
20
mA
Input Voltage @ 10 mA
2
3
Vdc
Must Turn-On Current
8
mA
Must Turn-Off Current100
µA
Must Turn-Off Voltage
Vdc
Reverse Polarity
–6
OUTPUT (LOAD) SPECIFICATIONS
Vdc
Max
Units
0
80
Vdc
500
mA
Leakage Current at Rated Voltage10
µA
Transient Blocking Voltage @25°C
100
Vdc
Output Capacitance @25Vdc (25°C)
600
pF
Output Voltage Drop @500mA
0.5
Vdc
On Resistance1.0
Ohm
Output Current Rating (See Figure 5)
Turn-On Time
2.0
ms
Turn-Off Time1.0
ms
Trip Overload
(See Figure 6)
Short-Circuit Protection
60
DESCRIPTION
ZD24CC Series Relays have optical isolation
between relay input and output. Loads may be
connected to either the positive or negative output
terminals. ZD24CC Relays act as electronic circuit
breakers that sense shorted loads or other overload
no current flows through the relay and associated
loads. These relays prevent overcurrent damage
to the system. ZD24CC Series Relays have Trip
Status to indicate a latched-off relay condition.
Cycling the relay on-off removes the tripped or
latched-off condition and returns the relay to the
normal operating state.
A
Vdc
Max
Units
Status Leakage Current @ 15 Vdc
5
µA
Status Blocking Voltage
32
Vdc
Status “On” Voltage @ 10 mAdc
0.4
Vdc
Status “On” Current10
mA
© 2006 TELEDYNE RELAYS
• Compact 6-pin package
STATUS OUTPUT TRUTH TABLE
Output (Switch) State Tripped
STATUS SPECIFICATIONS
Min
• Optical isolation
events and then trip-off. Relay contacts open and
Min
Load Voltage Range
• Short-circuit protected
• Overload protected
Min
0.8
FEATURES/BENEFITS
Not Tripped
(800) 284-7007 • www.teledynerelays.com
Status Output Level
Low (≤0.4 Vdc)
High (open collector)
ZD24 Page 2DSZD24CC Rev B
ZD24CC Series
500mA, 80 Vdc Optically Isolated
Short-Circuit Protected with Trip Status
TYPICAL WIRING DIAGRAM
GENERAL SPECIFICATIONS
(+25°C ambient temperature unless otherwise specified)
ENVIRONMENTAL SPECIFICATIONS
Min
Max
Units
Operating Temperature
–55
+105
°C
Status
Storage Temperature
–55
+125
°C
–IN
Junction Temperature @0.5A
+125
°C
Thermal Resistance θJA
125
°C/W
1
6
2
5
ZD24
** Rs
+IN
3
4
LOAD
+
LOAD
–
*
*Shorted internally
**Series resistor required to limit input current to 20mA maximum
Dielectric Strength1000
Vac
Figure 2
Insulation Resistance
(@500 Vdc)109
Ohm
CONTROL CURRENT VS. INPUT VOLTAGE
5
pF
Shock
MIL STD 202, method 213, cond. F, 1500 g
Vibration
MIL STD 202, method 204, cond. F, 1500 g
Resistance to Soldering Heat MIL STD 202, method 210
Solderability
MIL STD 202, method 208
Thermal Shock
MIL STD 202, method 107
MECHANICAL SPECIFICATIONS
5
2
0.065
(1.65)
MIN.
0.250
(6.35)
SZD24
1
0.195
(4.95)
DATE
CODE
4
0.290
(7.37)
3
0.390 (9.91)
6
4
2
0
0
.5
1.0
1.5
2.0
Volts
2.5
3.0
3.5
TURN-ON TIME VS. INPUT CURRENT
0.90
0.010
(0.25)
0.75
0.60
0.45
0.30
0.15
PIN-OUTS
PIN NO.
FUNCTION
1
+IN
2
STATUS
3
–IN
4
–OUT
5
–OUT
6
+OUT
4
ZD24
2
8
Figure 3
0.025
(0.64)
0.200
(5.08)
1
10
0.100
(2.54)
Tolerances: .XX = ±0.010 (±0.25), .XXX = ±0.005 (±0.13)
Controlling dimensions are in inches. Metric
dimensions are supplied for reference only.
PIN 1
INDEX
12
0.200
(5.08)
Weight: 0.035 oz. (1g) maximum
Case: 6-pin, dual-in-line, filled epoxy
5
14
0.37
(9.4)
0.018
(0.46)
6
16
SURFACE-MOUNT LAND PATTERN
0.175
(4.45)
0.025
(0.64)
REF
18
Turn-On Time (ms)
6
0.025
(0.64)
MIN.
+105°C +25°C –55°C
20
Control Current (mA)
Input to Output Capacitance
0
5
10
15
Input Current (mA)
20
Figure 4
3
0.30
(0.762)
0.085 (2.16)
0.020
(0.51)
MIN.
0.100
(2.54)
0.15
(3.81)
0.100
(2.54)
MIN.
10° ±5°
0.10
(0.25)
Figure 1
ZD24 Page Specifications are subject to change without notice
© 2006 TELEDYNE RELAYS
2DSZD24CC Rev B
ZD24CC Series
500mA, 80 Vdc Optically Isolated
Short-Circuit Protected with Trip Status
LOAD CURRENT VS. AMBIENT TEMPERATURE
600
Load Current (mA)
500
400
300
200
100
0
–55
–35
–15
5
25
45
65
Ambient Temperature (°C)
85
105
125
Figure 5
TYPICAL OVERLOAD TRIP CURRENT VS. TIME
2.50
2.25
–55°C
Load Current (A)
2.00
1.75
+25°C
1.50
1.25
1.00
+105°C
0.75
0.50
0.25
0
0.1
1.0
10
100
Trip Time (Seconds)
1000
10000
Figure 6
FUNCTIONAL BLOCK DIAGRAM
(1) +IN
INPUT
with
LEDs
Optical
Isolation
Detection
Circuit
Switching
Circuit
(3) –IN
Output Switch
(MOSFET)
with Current
Sense
+OUT (6)
–OUT (4)
(2) TRIP STATUS
Figure 7
NOTES:
1. The ZD24CC relay’s input current should be limited to between 8 and 20mA. An external resistor whose value =(VIN – 2.5 volts) ÷ 0.012 Amps is a
good choice for limiting input current.
2. Relay input transitions should be less than 1.0 millisecond.
3. Loads may be attached to either the positive or negative output terminal.
4. Maximum load current ratings are with the relay in free air and soldered to a printed circuit board.
5. Timing is measured from the input current transition to the 10% or 90% points on the output voltage transition.
6. Overload conditions (including shorted loads) are specified for load supply voltages to 60 Vdc maximum.
7. For through-hole-PCB-solder-attaching ZD24CC Series Relays, the wave-solder or solder pot operations are limited to +260°C maximum for 10
seconds, maximum.
8. For surface-mount-solder-attaching SZD24CC Series Relays, in IR heating or convection heating systems, the component temperature is limited to
+235°C maximum for 10 seconds maximum.
© 2006 TELEDYNE RELAYS
(800) 284-7007 • www.teledynerelays.com
ZD24 Page 2DSZD24CC Rev B