Data sheet OT12/230-240/10

product details
OT 12/230-240/10 UNV1
Product description:
EAN/ Product:
Quantity:
OT 12/230-240/10 UNV1
4050300609232
Unpacked (UNV) contains 1 Piece (PCE)
Applications
Dimmable
Yes 1)
IP code
IP20
Cable cross-section, output side
H03VV-F 2 x 0.75 mm² | NYM 3 x 1.5 mm²
Cable cross-section, input side
H03VV-F 2 x 0.75 mm² | NYM 3 x 1.5 mm²
Short-circuit protection
automatic reversible
Overload protection
automatic reversible
Overtemperature protection
automatic reversible
General Description
Design / version
ECG standard
SEG no.
5280323
Standards
acc. to IEC 61347-2-13 | acc. to IEC 62384 | acc. to EN 55015 | acc. to IEC 610003-2 | acc. to IEC 61000-3-3 | acc. to IEC 61547
Sstl-Number
4030666
Technical - Electrical Data
Mains frequency
50-60 Hz
TH full width at half maximum
95 µs
Device power loss
... 3.5 W 2)
Lamp wattage
12 W 3)
Power factor c
> 0.9
Nominal voltage
230-240 V
Output voltage
10.5 ± 0.5 V
Max. no. of ECGs on circuit breaker 10A
90
Max. no. of ECGs on circuit breaker 16A
135
Technical - Geometries
Width
50 mm
Height
35 mm
Length
109 mm
Max. cable length - system in meters
4m
Technical - Temperatures
Max. casing temp. in case of fault
90 °C
Max. operating temp. at the Tc point
70 °C
Ambient temperature range
-20 ... +50 °C
Storage temperature
-40 ... 85 °C
Relative humidity
5 ... 85 % 4)
Packaging units
EAN
Packaging type and content
Dimensions in h x w x l
Gross weight
Volume
4050300609232
Unpacked contains 1 Piece
52,000 mm x 34,000 mm x 108,000 mm
98,250 g (0,000 g)
0,191 Cubic
dec.
product details
OT 12/230-240/10 UNV1
Packaging units
EAN
Packaging type and content
Dimensions in h x w x l
Gross weight
Volume
4050300609249
Shipping carton box contains 20 Piece
229,000 mm x 94,000 mm x 270,000 mm
2.083,000 g (0,000 g)
5,812 Cubic
dec.
1)
with OPTOTRONIC dimmers
2)
maximum
3)
at 100% luminous flux
4)
max. 56 d/y at 85%
product details
OT 12/230-240/10 UNV1
Geometry
Wiring diagram
Instruction sheet
Please consult the instruction sheet for further important information on dimming
characteristic, wire stripping and wiring limitations in system installations. The