S240 series WWW.ASTRODYNE.COM

S240
2 4 0 W S i n g l e O u t put Switching Power Supply
series
Auto switched 88 ~ 264VAC input
Built-in passive PFC choke
Protections: Short circuit / Overload / Over voltage / Over
temperature
Forced air cooling by built-in DC fan
Built in cooling FAN ON-OFF control
LED indicator for power on
Fixed switching frequency at 75KHz
Model Number
Output Volts
Output Amps
OVP
5 Volts(DC)
7.5 Volts(DC)
12 Volts(DC)
15 Volts(DC)
24 Volts(DC)
30 Volts(DC)
48 Volts(DC)
40 Amps
30 Amps
18 Amps
15 Amps
10Amps
8 Amps
5 Amps
6.0~ 7.0Volt(DC)
9.4~ 10.9Volt(DC)
14.4 ~ 16.8Volt(DC)
18.5 ~ 21.5Volt(DC)
31.2 ~ 36Volt(DC)
34.5~ 40.5Volt(DC)
57.6~ 67.2Volt(DC)
Min Load
DC Volt Adjust
Efficiency
SINGLE OUTPUT
S240-5
S240-7.5
S240-12
S240-15
S240-24
S240-30
S240-48
WWW.ASTRODYNE.COM
0~40Amps
0~30Amps
0~18Amps
0~15Amps
0~10Amps
0~8Amps
0~5Amps
4.5~5.8Volt(DC)
78%
6~9Volt(DC)
80%
10~14Volt(DC) 82%
12~18Volt(DC)
83%
20~28Volt(DC)
84%
27~33Volt(DC)
85%
41~56Volt(DC)
87%
ASTRODYNE USA: 1-800-823-8082
ASTRODYNE PACIFIC: 886-2-26983458
S240
2 4 0 W S i n g l e O u t put Switching Power Supply
Insulation Resistance
EMI
Input Voltage Range
90~132VAC/176~264VAC auto switch Harmonic Current
248~370 Volts(DC) Remote Control
Frequency Range
47-63 Hz Inrush Current, typ: (cold start)
15Amps/115VAC; 30Amps 230VAC Efficiency
Input Current
5.0 Amps @ 115VAC Isolation
2.5 Amps @ 230VAC Leakage current
< 2.0 mAmps / 240VAC Min Load
See Selection Chart EMS
Power Factor @ FL
PF> 0.95 / 230VAC > 0.95 / 115VAC INPUT SPECIFICATIONS
series
≥ 100MΩ / 500Volts(DC)
Compliance to EN55022B (CISPR22B)
Compliance to EN61000-3-2,-3
RC+/RC-: short= Power on
Open= Power off
See Selection Chart
3000VAC Input - Output
1500VAC Input - Ground
500VAC Output - Ground
Compliance to EN61000-4-2,3,4,5,6,8,11
ENV50204, light Industry Level, Criteria A
OUTPUT SPECIFICATIONS
ENVIRONMENTAL SPECIFICATIONS
Voltage and Current See Selection Chart
Line Regulation
±0.5%: 5~30Volts(DC)
±1.0%: 48Volts(DC)
Load Regulation
±1.0%: 5;7.5;48Volts(DC)
Voltage Tolerance (Note 2) ±2.0%: 5~7.5Volts(DC)
±1.0%: 12~48Volts(DC)
Ripple/Noise (Note 1)
150mVpk-pk: 5;12;15Volts(DC)
180mVpk-pk: 24~30Volts(DC)
200mVpk-pk: 7.5Volts(DC)
240mVpk-pk: 48Volts(DC) Hold Up Time @ FL
36mS
Setup, Rise Time @ FL 1000mS, 20mS
Over Voltage Protection See Selection Chart
Hiccup mode, auto recovers
Over Current Protection 105~135% rated output power
Hiccup mode, auto recovers
DC Volt Adjust
See Selection Chart
Fan Control, O.T.P
RT1≥ 40°C FAN ON
≤ 35°C FAN OFF
≥ 70°C output shutdown
Oper. Temperature
Storage Temperature
Relative Humidity
Temperature Coefficient
MTBF
Vibration
-10°C to +60°C (See Derate Curve)
-20°C to +85°C, 10~95% RH
20~90% RH non cond
±0.03% / °C (0-50°C) 179.3KHrs min,MIL-HDBK-217F(25°C)
10~500Hz, 2G10min./1cycle, period for 60min. each along X, Y, Z axes
PHYSICAL SPECIFICATIONS
Size
Weight
190x 93 x 65mm (7.48”x3.66 ”x2.56”)
42.33 oz (1200g)
Note
1. Ripple & noise are measured at 20MHz of bandwidth by using a 12”
twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
2. Tolerance : includes set up tolerance, line regulation and load regulation.
GENERAL SPECIFICATIONS
Safety
UL60950-1, TUV EN60950-1 Approved
7.5Volts(DC) design refer to TUV EN6050-1
All specifications are typical at nominal input, full load, and 25°C unless otherwise noted
WWW.ASTRODYNE.COM
Astrodyne products are not authorized or warranteed for use
as critical components in life support systems, equipment used
in hazardous environments, nuclear controls systems, or other
mission-critical applications.
ASTRODYNE USA: 1-800-823-8082
ASTRODYNE PACIFIC: 886-2-26983458
2 4 0 W S i n g l e O u t put Switching Power Supply
WWW.ASTRODYNE.COM
S240
series
ASTRODYNE USA: 1-800-823-8082
ASTRODYNE PACIFIC: 886-2-26983458
2 4 0 W S i n g l e O u t put Switching Power Supply
WWW.ASTRODYNE.COM
S240
series
ASTRODYNE USA: 1-800-823-8082
ASTRODYNE PACIFIC: 886-2-26983458