S240 2 4 0 W S i n g l e O u t put Switching Power Supply series Auto switched 88 ~ 264VAC input Built-in passive PFC choke Protections: Short circuit / Overload / Over voltage / Over temperature Forced air cooling by built-in DC fan Built in cooling FAN ON-OFF control LED indicator for power on Fixed switching frequency at 75KHz Model Number Output Volts Output Amps OVP 5 Volts(DC) 7.5 Volts(DC) 12 Volts(DC) 15 Volts(DC) 24 Volts(DC) 30 Volts(DC) 48 Volts(DC) 40 Amps 30 Amps 18 Amps 15 Amps 10Amps 8 Amps 5 Amps 6.0~ 7.0Volt(DC) 9.4~ 10.9Volt(DC) 14.4 ~ 16.8Volt(DC) 18.5 ~ 21.5Volt(DC) 31.2 ~ 36Volt(DC) 34.5~ 40.5Volt(DC) 57.6~ 67.2Volt(DC) Min Load DC Volt Adjust Efficiency SINGLE OUTPUT S240-5 S240-7.5 S240-12 S240-15 S240-24 S240-30 S240-48 WWW.ASTRODYNE.COM 0~40Amps 0~30Amps 0~18Amps 0~15Amps 0~10Amps 0~8Amps 0~5Amps 4.5~5.8Volt(DC) 78% 6~9Volt(DC) 80% 10~14Volt(DC) 82% 12~18Volt(DC) 83% 20~28Volt(DC) 84% 27~33Volt(DC) 85% 41~56Volt(DC) 87% ASTRODYNE USA: 1-800-823-8082 ASTRODYNE PACIFIC: 886-2-26983458 S240 2 4 0 W S i n g l e O u t put Switching Power Supply Insulation Resistance EMI Input Voltage Range 90~132VAC/176~264VAC auto switch Harmonic Current 248~370 Volts(DC) Remote Control Frequency Range 47-63 Hz Inrush Current, typ: (cold start) 15Amps/115VAC; 30Amps 230VAC Efficiency Input Current 5.0 Amps @ 115VAC Isolation 2.5 Amps @ 230VAC Leakage current < 2.0 mAmps / 240VAC Min Load See Selection Chart EMS Power Factor @ FL PF> 0.95 / 230VAC > 0.95 / 115VAC INPUT SPECIFICATIONS series ≥ 100MΩ / 500Volts(DC) Compliance to EN55022B (CISPR22B) Compliance to EN61000-3-2,-3 RC+/RC-: short= Power on Open= Power off See Selection Chart 3000VAC Input - Output 1500VAC Input - Ground 500VAC Output - Ground Compliance to EN61000-4-2,3,4,5,6,8,11 ENV50204, light Industry Level, Criteria A OUTPUT SPECIFICATIONS ENVIRONMENTAL SPECIFICATIONS Voltage and Current See Selection Chart Line Regulation ±0.5%: 5~30Volts(DC) ±1.0%: 48Volts(DC) Load Regulation ±1.0%: 5;7.5;48Volts(DC) Voltage Tolerance (Note 2) ±2.0%: 5~7.5Volts(DC) ±1.0%: 12~48Volts(DC) Ripple/Noise (Note 1) 150mVpk-pk: 5;12;15Volts(DC) 180mVpk-pk: 24~30Volts(DC) 200mVpk-pk: 7.5Volts(DC) 240mVpk-pk: 48Volts(DC) Hold Up Time @ FL 36mS Setup, Rise Time @ FL 1000mS, 20mS Over Voltage Protection See Selection Chart Hiccup mode, auto recovers Over Current Protection 105~135% rated output power Hiccup mode, auto recovers DC Volt Adjust See Selection Chart Fan Control, O.T.P RT1≥ 40°C FAN ON ≤ 35°C FAN OFF ≥ 70°C output shutdown Oper. Temperature Storage Temperature Relative Humidity Temperature Coefficient MTBF Vibration -10°C to +60°C (See Derate Curve) -20°C to +85°C, 10~95% RH 20~90% RH non cond ±0.03% / °C (0-50°C) 179.3KHrs min,MIL-HDBK-217F(25°C) 10~500Hz, 2G10min./1cycle, period for 60min. each along X, Y, Z axes PHYSICAL SPECIFICATIONS Size Weight 190x 93 x 65mm (7.48”x3.66 ”x2.56”) 42.33 oz (1200g) Note 1. Ripple & noise are measured at 20MHz of bandwidth by using a 12” twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 2. Tolerance : includes set up tolerance, line regulation and load regulation. GENERAL SPECIFICATIONS Safety UL60950-1, TUV EN60950-1 Approved 7.5Volts(DC) design refer to TUV EN6050-1 All specifications are typical at nominal input, full load, and 25°C unless otherwise noted WWW.ASTRODYNE.COM Astrodyne products are not authorized or warranteed for use as critical components in life support systems, equipment used in hazardous environments, nuclear controls systems, or other mission-critical applications. ASTRODYNE USA: 1-800-823-8082 ASTRODYNE PACIFIC: 886-2-26983458 2 4 0 W S i n g l e O u t put Switching Power Supply WWW.ASTRODYNE.COM S240 series ASTRODYNE USA: 1-800-823-8082 ASTRODYNE PACIFIC: 886-2-26983458 2 4 0 W S i n g l e O u t put Switching Power Supply WWW.ASTRODYNE.COM S240 series ASTRODYNE USA: 1-800-823-8082 ASTRODYNE PACIFIC: 886-2-26983458