39 Series Plug Termination Instructions
1.
2.
3.
BROWN PAIR
ORANGE PAIR
Remove 1.25” (31.8 mm) of cable
jacket. Slit both sides of jacket back
.375” (9.5 mm). The slits should be
located where the two outer pairs
exit jacket. Separate the pairs.
Arrange pairs according to appropriate
wiring diagram (see back of sheet). If
pairs need to be crossed, keep twisted
and cross inside jacket.
Straighten conductors and align per
diagram Only untwist enough
conductors to allow insertion into
loadbar.
4.
5.
6.
Insert outer pairs of conductors into
loadbar as shown.
Turn assembly over and insert
center pair into loadbar.
Turn assembly back. Trim the last
pair slightly to make loading easier
and insert into loadbar.
7.
8.
9.
Push loadbar back onto cable until
the edge of jacket is even with the
notch in the loadbar. Pull any slack
out of the conductors. Twist should
be as close to loadbar as possible
for best performance
Ensure that all conductors are flat
and straight in loadbar area. Trim
all conductors flush with edge of
loadbar.
Insert loadbar into the housing and
terminate.
MN390008 A1
11118 Susquehanna Trail South
Glen Rock, PA 17327-9199
Tel: 717-25-7512 • Fax: 717-235-7954
Bel Stewart Connector
www.stewartconnector.com
39 Series Plug Wiring Sequences
EIA/TIA 568-B
Notes:
• Category 6 Plug can terminate 28 to 24 AWG
• For technical and performance data, consult
factory
• Insulated conductor O.D. range = .042 - 0.37
As with all wiring installation and modification, the following
statements apply:
Use caution and common sense when installing, modifying, or
removing any communication wiring and systems.
Never install communications wiring in wet locations unless
electronic components and jacks are specifically designed for
wet environments.
Always disconnect communication lines from the network
interface before touching uninsulated communications wiring or
terminals.
Do not, under any circumstances, install communications wiring
during a lightening storm.
MN390008 A1