FL75L10 A - Delta Electronics

FL75R10A Filter Module
75Vdc Input Maximum, 10A Maximum
FEATURES

ROHS Compliant

Small size: 50.8 mm x 27.9 mm x 11.7mm
(2.0” x 1.1” x 0.46“)

Industry standard footprint and pin-out

Optimized for use with high frequency
board mounted DC/DC converters

ISO 9001, TL 9000, ISO 14001, QS9000,
OHSAS18001 certified manufacturing
facility

Printed-circuit board mountable
Delphi Series Filter Module - FL75L10A
75Vdc max input, 10A max output current
The Delphi series FL75L10A filter module is the latest offering from a
world leader in power systems technology and manufacturing -- Delta
Electronics, Inc. This filter module is designed to reduce the conducted
common-mode and differential-mode noise on input or output lines of
high-frequency switching power supplies and has a maximum current
rating of 10A. It has the industry standard footprint and pin-out. With
creative design technology and optimization of component placement,
Delphi FL75L10A filter module possesses outstanding electrical and
thermal performance, as well as extremely high reliability under highly
stressful operating conditions.
APPLICATIONS

Common-mode and differential-mode
filtering of power supply dc input and
output line
DATASHEET
DS_FL75L10_ 07162007

Computer application

Communications equipment
SPECIFICATIONS
GENERAL SPECIFICATIONS
OUTPUT SPECIFICATIONS
Input voltage, continuous
Typical
0~75V
Output current
Ta=70°C, no airflow
10A
Input voltage, transient
Typical
100V
Output current
Ta=85°C, no airflow
8A
Operation case temperature Typical
-40℃ ~ 110℃
Common-mode Insertion Loss
50Ω circuit, 500 kHz (Typ) 30dB
Storage temperature
Typical
-55℃ ~ 125℃
Differential-mode Insertion Loss 50Ω circuit, 500 kHz (Typ) 25dB
Size
(2.0”x1.1”x0.46”)
50.8 mm x27.9 mm x11.7 mm
ELECTRICAL CHARACTERISTICS CURVES
Figure 1: Typical common-mode insertion loss in a 50Ω circuit
Figure 2: Typical differential-mode insertion loss in a 50Ω
circuit
Internal Schematics
Figure 3: Internal schematics
2
THERMAL CONSIDERATIONS
THERMAL CURVES
Thermal management is an important part of the system
design. To ensure proper, reliable operation, sufficient
cooling of the power module is needed over the entire
temperature range of the module. Convection cooling is
usually the dominant mode of heat transfer.
OUT
Hence, the choice of equipment to characterize the
thermal performance of the power module is a wind
tunnel.
GND
Thermal Testing Setup
Delta’s filter modules are characterized in heated vertical
wind tunnels that simulate the thermal environments
encountered in most electronics equipment. This type of
equipment commonly uses vertically mounted circuit
cards in cabinet racks in which the power modules are
mounted.
Figure 5: Temperature measurement location
The allowed maximum hot spot temperature is defined at 110℃
FL75L10 (Standard) Output Current vs. Ambient Temperature and Air Velocity
@ Vin = 48V (Either Orientation)
Output Current(A)
12
10
The following figure shows the wind tunnel
characterization setup. The filter module is mounted on a
test PWB and is vertically positioned within the wind
tunnel. The space between the neighboring PWB and the
top of the power module is 6.35mm (0.25”).
8
6
Natural
Convection
4
Thermal Derating
100LFM
2
Heat can be removed by increasing airflow over the
module. Figure 4 shows maximum output is a function of
ambient temperature and airflow rate. To enhance system
reliability, the power module should always be operated
below the maximum operating temperature. If the
temperature exceeds the maximum module temperature,
reliability of the unit may be affected.
0
50
55
60
65
70
75
80
85
Ambient Temperature (℃)
Figure 6: Output Current vs. Ambient Temperature and Air
Velocity @ Vin = 48V (Either Orientation)
PWB
FACING PWB
MODULE
AIR VELOCITY
AND AMBIENT
TEMPERATURE
MEASURED BELOW
THE MODULE
50.8 (2.0”)
AIR FLOW
10 (0.4”)
Note: Wind Tunnel Test Setup Figure Dimensions are in millimeters and (Inches)
Figure 4: Wind tunnel test setup figure dimensions are
in millimeters and (inches).
3
APPLICATION
Note: C2 through C5 can be 0.01μ F to o.1μ F. Select the voltage rating to meet input-to-output isolation requirements. C1 should be the recommended
value indicated in the power module data sheet.
Figure 7: Recommended schematic when used as the input filter to a high-frequency dc-to-dc converter
Note: Vdc input(+) and Vdc input(-) planes should overlay each other, as should the Vi(+) and Vi(-) planes, as should the Vout(+) and Vout(-) planes. Avoid
routing signals or planes under the power module or the filter module. Ensure all connections are low impedance.
Figure 8: Recommended layout when used as the input filter to a high-frequency dc-to-dc converter
4
APPLICATION (Con.)
Note: : C2 through C5 and C6 through C9 can be 0.01μ F to o.1μ F. Select the voltage rating to meet input-to-output isolation requirements. C1 should be
the recommended value indicated in the power module datasheet.
Figure 9: Recommended schematic of filter module with two power modules
5
Figure 10 shows the experimental result obtained by using this filter module, together with the recommended external
components shown in Figures 7 and 8. The Q48SR3R335NR module is one of the Delphi series quarter brick 3.3V, 35A
DCDC converters. Measured noise is greatly dependent on layout, grounding, cable orientation, and load characteristics
and the variation is possible from various application conditions.
Figure 10: Q48SR3R335NR A conducted noise with FL75L10 input filter
MECHANICAL DRAWING
Top View
Side View
Bottom View
Dimensions are in millimeter and (inches).
Tolerances : x.xx ± 0.5 mm (0.02 in), x.xxx ± 0.25 mm (0.010 in)
RECOMMENDED HOLE PATTERN
Dimensions are in millimeter and (inches).
Tolerances : x.xx ± 0.5 mm (0.02 in), x.xxx ± 0.25 mm (0.010 in)
6
PART NUMBERING SYSTEM
FL
75
L
10
Product Family
Input Voltage
Product Series
Output Current
FL- Input EMI Filter
75- 0 ~ 75V
L – Industry standard
10 - 10A
A
Space
Option Code
A - Standard Functions
B - 0.18” pin option
MODEL LIST
Module Name
Input Voltage (max.)
Current Rating (max.)
FL75L10 A
100V
10A
FL75L10 B
100V
10’A
CONTACT: www.deltaww.com/dcdc
USA:
Telephone:
East Coast: 978-656-3993
West Coast: 510-668-5100
Fax: (978) 656 3964
Email: [email protected]
Europe:
Telephone: +31-20-655-0967
Fax: +31-20-655-0999
Email: [email protected]
Asia & the rest of world:
Telephone: +886 3 4526107 ext 6220-6224
Fax: +886 3 4513485
Email: [email protected]
WARRANTY
Delta offers a two (2) year limited warranty. Complete warranty information is listed on our web site or is available upon request from Delta.
Information furnished by Delta is believed to be accurate and reliable. However, no responsibility is assumed by Delta for its use, nor for
any infringements of patents or other rights of third parties, which may result from its use. No license is granted by implication or otherwise
under any patent or patent rights of Delta. Delta reserves the right to revise these specifications at any time, without notice.
7