B84143*166

EMC filters
3-line filters
for converters and power electronics
Series/Type:
B84143A*166
Date:
May 2012
© EPCOS AG 2015. Reproduction, publication and dissemination of this publication, enclosures hereto and the
information contained therein without EPCOS' prior express consent is prohibited.
EPCOS AG is a TDK Group Company.
3-line filters
B84143A*166
for converters and power electronics
Power line filters for 3-phase systems
Rated voltage VR: 520/300 V AC
Rated current IR: 10 A to 35 A
Construction
3-line filters
Metal case
Features
Excellent price/performance ratio
Ultra-compact design
Low weight
Easy to install
Optimized for short motor cables
and operation under full load
ENEC10, UL and cUL approval
Typical applications
Frequency converters for motor drives, e.g.
elevators
pumps
HVAC systems (heating, ventilation and air
conditioning)
Power supplies
Terminals
Tab connectors (10 A ... 20 A)
Finger-safe terminal blocks (35 A)
Marking
Marking on component:
Manufacturer's logo, ordering code, rated voltage, rated
current, rated temperature, climatic category, date code,
approvals
Minimum data on packaging:
Manufacturer's logo, ordering code, quantity, date code
Please read Cautions and warnings and
Important notes at the end of this document.
Page 2 of 9
3-line filters
B84143A*166
for converters and power electronics
Typical circuit diagram
Technical data and measuring conditions
Rated voltage VR
Rated current IR
Test voltage Vtest
Climatic category (IEC 60068-1)
520/300 V AC (50/60 Hz)
Referred to 50 °C rated temperature1)
2236 V DC, 2 s (line/line)
2720 V DC, 2 s (lines/case)
1.5 IR for 3 min per hour or
2.5 IR for 30 s per hour
25/100/21 (25 °C/+100 °C/21 days damp heat test)
Approvals
IEC 60939, UL 1283, CSA C22.2 No.8
Overload capability (thermal)
1) For use at higher ambient temperature as the rated temperature, see current derating in our data book.
Characteristics and ordering codes
IR
A
Terminal
ILK1)
cross section
mm2
mA
VR = 520/300 V AC
10
5
3.1
20
5
3.1
35
6
5.0
Rtyp
Approx. weight
Ordering code
Approvals
B84143A0010A166
B84143A0020A166
B84143A0035R166
×
×
×
mΩ kg
12.9 0.6
4.9 0.75
2.7 1.1
× = Approval granted
1) Calculation according IEC 60939-1 (04.2011), annex A, "Calculation of leakage current" at VR, 50 Hz.
Please read Cautions and warnings and
Important notes at the end of this document.
Page 3 of 9
×
×
×
×
×
×
3-line filters
B84143A*166
for converters and power electronics
Dimensional drawings
B84143A0010A166, B84143A0020A166 (10 A, 20 A)
General tolerances according to ISO 2768C
Dimensions in mm
Please read Cautions and warnings and
Important notes at the end of this document.
Page 4 of 9
3-line filters
B84143A*166
for converters and power electronics
B84143A0035R166 (35 A)
General tolerances according to ISO 2768C
Dimensions in mm
Please read Cautions and warnings and
Important notes at the end of this document.
Page 5 of 9
3-line filters
B84143A*166
for converters and power electronics
Insertion loss (typical values at Z = 50 Ω)
Filter for 10 A
Filter for 20 A
Filter for 35 A
Please read Cautions and warnings and
Important notes at the end of this document.
Page 6 of 9
3-line filters
B84143A*166
for converters and power electronics
Cautions and warnings
Please note the advices in our data book “EMC Filters” (latest edition); attention should be paid
to the chapter “General safety notes”.
It shall be ensured that only qualified persons (electricity specialists) are engaged on work such
as planning, assembly, installation, operation, repair and maintenance. They must be provided
with the corresponding documentation.
Danger of electric shock. EMC filters contain components that store an electric charge. Dangerous voltages can continue to exist at the filter terminals for longer than five minutes even after
the power has been switched off.
The protective earth connections shall be the first to be made when the EMC filter is installed
and the last to be disconnected. Depending on the magnitude of the leakage currents, the particular specifications for making the protective-earth connection must be observed.
Impermissible overloading of the EMC filter, such as with circuits able to cause resonances, impermissible voltages at higher frequencies etc. can lead to bodily injury and death as well as
cause substantial material damages (e.g. destruction of the filter housing).
EMC filters must be protected in the application against impermissible exceeding of the rated
currents by overcurrent protective.
In case of leakage currents >3.5 mA you shall mount the PE conductor stationary with the required cross section before beginning of operation and save it against disconnecting. For leakage currents ILK1) <10 mA the PE conductor must have a KU value2) of 4.5; for leakage currents
ILK ≥10 mA the PE conductor must have a KU value of 6.
1) ILK = leakage current let-go
2) The KU value (symbol KU) is a classification parameter of safety-referred failure types designed to ensure protection against hazardous
body currents and excessive heating. A value of KU = 4.5 with respect to interruptions is attained: a) with a permanently connected protective earth circuit ≥1.5 mm2 and b) with a protective earth circuit ≥2.5 mm2 connected via shroud connectors (IEC 60309-2).
KU = 6 with respect to interruptions is achieved for fixed-connection lines ≥10 mm2 where the type of connection and line layout correspond to the requirements for PEN conductors as specified in relevant standards.
Please read Cautions and warnings and
Important notes at the end of this document.
Page 7 of 9
3-line filters
B84143A*166
for converters and power electronics
Symbols and terms
Symbol
α
CR
CX
CY
∆V
dv/dt
f
fM
fP
fR
fres
ILK
IC
Imax
IN
Iop
Iq
IR
IS
L
LR
Lstray
Ploss
R
Ris
Rtyp
TA
Tmax
Tmin
TR
Veff
VLE
VN
VR
Vpeak
Vtest
VX
VY
Z
|Z|
English
Insertion loss
Rated capacitance
Capacitance X capacitor
Capacitance Y capacitor
Voltage drop (input to output)
Rate of voltage rise
Frequency
Converter output frequency
Pulse frequency
Rated frequency
Resonant frequency
Filter leakage current
Current through capacitor
Maximum current
Nominal current
Operating current (design current)
Capacitive reactive current
Rated current
Interference current
Inductance
Rated inductance
Stray inductance
Power loss
Resistance
Insulation resistance
DC resistance, typical value
Ambient temperature
Upper category temperature
Lower category temperature
Rated temperature
RMS voltage
Voltage line to earth; voltage line to ground
Nominal voltage
Rated voltage
Peak voltage
Test voltage
Voltage over X capacitor
Voltage over Y capacitor
Impedance
Impedance, absolute value
Please read Cautions and warnings and
Important notes at the end of this document.
Page 8 of 9
German
Einfügungsdämpfung
Bemessungskapazität
Kapazität X-Kondensator
Kapazität Y-Kondensator
Spannungsabfall im Filter
Spannungsanstiegsgeschwindigkeit
Frequenz
Motorfrequenz
Pulsfrequenz
Bemessungsfrequenz
Resonanzfrequenz
Filter-Ableitstrom
Strom durch Kondensator
Maximalstrom
Nennstrom
Betriebsstrom
Kapazitiver Blindstrom
Bemessungsstrom
Störstrom
Induktivität
Bemessungsinduktivität
Streuinduktivität
Verlustleistung
Widerstand
Isolationswiderstand
Gleichstromwiderstand, Richtwert
Umgebungstemperatur
Obere Kategorietemperatur
Untere Kategorietemperatur
Bemessungstemperatur
Effektivspannung
Spannung Phase zu Erdpotential
Netzspannung
Bemessungsspannung
Spitzenspannung
Prüfspannung
Spannung über X-Kondensator
Spannung über Y-Kondensator
Scheinwidertand
Scheinwiderstand (Betragswert)
Important notes
The following applies to all products named in this publication:
1. Some parts of this publication contain statements about the suitability of our products for
certain areas of application. These statements are based on our knowledge of typical requirements that are often placed on our products in the areas of application concerned. We
nevertheless expressly point out that such statements cannot be regarded as binding
statements about the suitability of our products for a particular customer application.
As a rule, EPCOS is either unfamiliar with individual customer applications or less familiar
with them than the customers themselves. For these reasons, it is always ultimately incumbent on the customer to check and decide whether an EPCOS product with the properties described in the product specification is suitable for use in a particular customer application.
2. We also point out that in individual cases, a malfunction of electronic components or
failure before the end of their usual service life cannot be completely ruled out in the
current state of the art, even if they are operated as specified. In customer applications
requiring a very high level of operational safety and especially in customer applications in
which the malfunction or failure of an electronic component could endanger human life or
health (e.g. in accident prevention or lifesaving systems), it must therefore be ensured by
means of suitable design of the customer application or other action taken by the customer
(e.g. installation of protective circuitry or redundancy) that no injury or damage is sustained by
third parties in the event of malfunction or failure of an electronic component.
3. The warnings, cautions and product-specific notes must be observed.
4. In order to satisfy certain technical requirements, some of the products described in this
publication may contain substances subject to restrictions in certain jurisdictions (e.g.
because they are classed as hazardous). Useful information on this will be found in our Material Data Sheets on the Internet (www.epcos.com/material). Should you have any more detailed questions, please contact our sales offices.
5. We constantly strive to improve our products. Consequently, the products described in this
publication may change from time to time. The same is true of the corresponding product
specifications. Please check therefore to what extent product descriptions and specifications
contained in this publication are still applicable before or when you place an order. We also
reserve the right to discontinue production and delivery of products. Consequently, we
cannot guarantee that all products named in this publication will always be available. The
aforementioned does not apply in the case of individual agreements deviating from the foregoing for customer-specific products.
6. Unless otherwise agreed in individual contracts, all orders are subject to the current version of the "General Terms of Delivery for Products and Services in the Electrical Industry" published by the German Electrical and Electronics Industry Association
(ZVEI).
7. The trade names EPCOS, BAOKE, Alu-X, CeraDiode, CeraLink, CSMP, CSSP, CTVS,
DeltaCap, DigiSiMic, DSSP, FilterCap, FormFit, MiniBlue, MiniCell, MKD, MKK, MLSC,
MotorCap, PCC, PhaseCap, PhaseCube, PhaseMod, PhiCap, SIFERRIT, SIFI, SIKOREL,
SilverCap, SIMDAD, SiMic, SIMID, SineFormer, SIOV, SIP5D, SIP5K, ThermoFuse,
WindCap are trademarks registered or pending in Europe and in other countries. Further
information will be found on the Internet at www.epcos.com/trademarks.
Page 9 of 9