das-1719-4001.pdf

DAS-1721-4001
AWS/PCS MISO DAS Conditioning Tray
MISO E-Node B Configuration DAS System
Features
• Provides a single connection point for cellular base
stations in either AWS or PCS spectrum at either BTS
port
• Integrated variable step attenuation for each channel
• Adjustment range of 30 dB with 1 dB increments
• MISO deployment configuration
• Passive DAS assembly without external power
requirements
• Each BTS port feeds both sectors A & B & both sectors
to a single BTS port
API's DAS Interface Tray provides a single connection point when using single or multiple base stations by standardizing the
connection between the BTS and the DAS head-end equipment and improving the uplink signal with minimal impact to the
receive signal. API's low PIM DAS Interface Tray provides integrated variable step attenuation in the Tx (DL) path for each input
with an adjustment range of 30 dB with 1 dB increments.
Technical Specifications
RF
Electrical
Frequency
Range:
AWS / PCS
Mechanical
Typical Specifications
AWS/PCS 2
AWS/PCS 1
UL: 1710 – 1910 MHz
DL: 1930 – 2155 MHz
UL: 1710 – 1910 MHz
DL: 1930 – 2155 MHz
Number of DAS
Connections
Number of BTS
Connections
DL (TX) Loss
24.5 dB +/- 1
(20 dB cable attenuator installed. Other
attenuation levels available upon request)
Number of LMU
Connections
UL (RX) Loss
4.25 – 34.5 dB in1 dB steps
Dimensions
Input power
Return Loss
(VSWR)
PIM3
Maximum 80 Watts per Input Port
-18 dB (1.3:1)
Specification
2 Each:
2 Each:
2 Each:
Tx1 Monitor (SMA-F)
Tx2 Monitor (SMA-F)
Operational Temp
0°C to +50°C
Finish
White Epoxy Paint
(Rack Panel only)
1 RU Rack
(front mount ears)
Rev Date: 5/05/15
© API Technologies Corp. Proprietary Information
1 – Tx/Rx1 (N-F)
1 – Tx/Rx2 (N-F)
Standard 1 RU 19” rack mount
Actual dim:
1.75” (H) 19” (W) 17.25” (D)
Mounting
≥ -153 dBc
1 – Sector Tx (N-F)
1 – Sector Rx (N-F)
Page # 1
|
www.apitech.com
|
micro.apitech.com
|
+1.888.553.7531
|
[email protected]
DAS-1721-4001
AWS/PCS MISO DAS Conditioning Tray
MISO E-Node B Configuration DAS System
Front Panel
0
20
1
0 10
3 2
DAS Rx
4
20
4
Tx 2
10
DAS Tx
9 8 7
9 8 7
3 2
0 10
Rx 2 Level Adj
6 5
1
Monitor
Tx 1
0
10
Rx 1 Level Adj
6 5
Tx/RX 1
Tx/RX 2
Functional Block Diagram
Rev Date: 5/05/15
© API Technologies Corp. Proprietary Information
Page # 2
|
www.apitech.com
|
micro.apitech.com
|
+1.888.553.7531
|
[email protected]