ASH 10

AC-DC CONVERTER
ENCAPSULATED PACKAGE
ASH-10 Series, 10Watt
FEATURES:
Universal AC input/full range
Low ripple and noise
Short circuit, over current, over voltage protections
High efficiency, high density
100% burn-in test
3 year warranty
Output 1
(Vdc/mA)
Output 2
(Vdc/mA)
Output power
(W)
ASH10-3
3.3V/2000mA
/
6.6
ASH10-5
5V/2000mA
/
10
ASH10-9
9V/1100mA
/
10
ASH10-12
12V/900mA
/
10
ASH10-15
15V/700mA
/
10
ASH10-24
24V/450mA
/
10
+5V/1000mA
-5V/1000mA
10
+12V/450mA
-12V/450mA
10
ASH10-D15
+15V/350mA
-15V/350mA
10
ASH10-D24
+24V/200mA
-24V/200mA
10
ASH10-D0505
5V/1800mA
5V/200mA
10
ASH10-D0512
5V/1500mA
12V/200mA
10
ASH10-D0515
5V/1400mA
15V/200mA
10
ASH10-D0524
5V/1000mA
24V/200mA
10
Model
ASH10-D5
ASH10-D12
Input voltage
(Vac)
85~265
Note: Other output models may available on request.
ELECTRICAL
Input
Parameters
Symbols
Test Conditions / Comment
Input voltage
Vin
--
Input frequency
Fline
--
47
Leakage current
Ileakage
Vin =230Vac/50Hz
--
www.pairuigroup.com
Page: 1 / 5
Min.
85
120
Typ.
Max.
Units
265
Vac
370
Vdc
--
63
Hz
--
0.3
mA
--
Date: 03/07/2016
AC-DC CONVERTER
ENCAPSULATED PACKAGE
ASH-10 Series, 10Watt
ELECTRICAL
Input
Parameters
Input current
Inrush current
Symbols
Test Conditions / Comment
Min.
Typ.
Max.
Units
Full load, Vin =115Vac
--
260
--
mA
Full load, Vin =230Vac
--
160
--
mA
Cold start, full load, Vin =115Vac
--
10
--
A
Cold start, full load, Vin =230Vac
--
20
--
A
Iin
Iinrush
Output
--
--
--
±2.0
--
%
Line regulation
Vout-line
--
--
±2.0
--
%
Load regulation
Vout-load
10%~100% load
--
±1.5
--
%
η
--
--
70
--
%
Vripple
20MHz
--
50
100
mVp-p
-25
--
+105
°C
-25
--
+70
°C
Non condensing
10
--
95
%
--
--
0.02
--
%/ °C
300
--
--
kHrs
Output voltage accuracy
Efficiency
Ripple
Protection
Short circuit
Hiccup mode, it will auto-recover after fault condition is removed
Over current
≥110%Io, it will auto-recover after fault condition is removed
Over voltage
Diode clamp
Environment
Storage
Ambient operating
temperature
Operating relative
humidity
Temperature coefficient
MTBF
www.pairuigroup.com
Tstorage
Ta
Ha
--
TMTBF
Humidity: 10% RH to 95% RH
Startup at rated voltage(please refer
to derating curve)
MIL-HDBK-217F(25°C)
Page: 2 / 5
Date: 03/07/2016
AC-DC CONVERTER
ENCAPSULATED PACKAGE
ASH-10 Series, 10Watt
ELECTRICAL
Environment
Dimension(LxWxH)
55.0 x 45.0 x 21.0mm
Safety / EMC
Safety standards
Design refer to UL1012, UL60950, UL60950
Isolation voltage
I/P-O/P:3.0KVAC
EMC
EN55022 Class B, EN55024
Notes: Unless otherwise specified, all the above parameters are measured at ambient temperature of 25°C and
Vin = 85Vac to 265Vac.
MECHANICAL
PIN DEFINITION
Pin
SINGLE
DUAL
TWO
1
FG
FG
FG
2
AC(N)
AC(N)
AC(N)
3
AC(L)
AC(L)
AC(L)
4
+Vo
+Vo
+Vo2
5
No Pin
No Pin
-Vo2
6
No Pin
COM
No Pin
7
No Pin
No Pin
+Vo1
8
-Vo
-Vo
-Vo1
Unit: mm
www.pairuigroup.com
Page: 3 / 5
Date: 03/07/2016
AC-DC CONVERTER
ENCAPSULATED PACKAGE
ASH-10 Series, 10Watt
ELECTRICAL CURVE
DERATING CURVE
STATIC CHARACTERISTIC CURVE
NOTE
RECOMMENDED TEST AND APPLICATION CIRCUIT
www.pairuigroup.com
Page: 4 / 5
Date: 03/07/2016
AC-DC CONVERTER
ENCAPSULATED PACKAGE
ASH-10 Series, 10Watt
NOTE
RECOMMENDED EMC TEST CIRCUIT
Component
Recommended Value
FUSE
1A/250V, Slow rating
MOV
14D-561K
CY1, CY2
1000pF/400Vac
CX
0.1uF/275Vac
LCM
10mH
LDM
4.7uH/2a
www.pairuigroup.com
Page: 5 / 5
Date: 03/07/2016