G6DN PCB Power Relay SPST Slim Power Relay for 5 A switching • Slim 5-mm width and miniature size. (20 × 5.08 × 12.5 mm) • High switching capability 5 A (250 VAC and 30 VDC), and high contact reliability by crossbar-twin contact. • Power consumption 110 mW of an industry top class. • Meets application standards EN61010-1 and EN61010-2-201 for reinforced insulation, and EN60335-1 for basic insulation. ■Model Number Legend ■Application Examples G 6 D N -@@ @ ——— • • • • 1 2 3 1. Number of Poles 1: 1-pole 3. Enclosure Rating None: Fully sealed Programmable Controller output Temperature Controller Building Automation Output of control system G 6 D N 2. Contact Form A: SPST-NO (1a) ■Ordering Information Contact form Enclosure rating Terminal shapes Model Minimum packing unit SPST-NO (1a) Fully sealed PCB terminal G6DN-1A 25 pcs/ tube Note. When ordering, add the rated coil voltage to the model number. Example: G6DN-1A DC5 Rated coil voltage However, the notation of the coil voltage on the product case as well as on the packaging will be marked as @@ VDC. Example: G6DN-1A 5VDC ■Ratings ●Coil Rated current (mA) Coil resistance (Ω) Must operate voltage Must release voltage (V) (V) % of rated voltage Rated voltage 4.5 VDC 24.4 184 5 VDC 22.0 227 12 VDC 9.2 1,309 24 VDC 4.6 5,236 Max. voltage (V) 70% max. * 5% min. 160% Power consumption (mW) Approx. 110 Note. The rated current and resistance are measured at a coil temperature of 23°C with a tolerance of ±10%. * Operating voltage is less than 72% when the relay is sideways and the marking is right way. ●Contacts Resistive load Contact Type Inductive load (cos φ = 0.4, L/R = 7 ms) Cross bar twin Contact material Ag-Alloy and Au plating * Rated load 5 A at 250 VAC 5 A at 30 VDC Rated carry current 5A Max. switching voltage 277 VAC, 125 VDC Max. switching current 5A Min. permissible load 0.1 mA at 0.1 VDC (at 120 operations/min) 2 A at 250 VAC 2 A at 30 VDC * Au plating is applied to stationary contact. 1 G6DN PCB Power Relay ■Characteristics Contact resistance 100 mΩ max. Operate time 10 ms max. Release time 5 ms max. Insulation resistance 1,000 MΩ min. (at 500 VDC) Between coil and contacts 3,000 VAC, 50/60 Hz for 1 min Dielectric strength Between contacts of the same polarity 750 VAC, 50/60 Hz for 1 min Surge withstand voltage Between coil and contacts 6 kV (1.2 ✕ 50 μs) Destruction 10 to 55 to 10 Hz, 2.5 mm single amplitude (5.0 mm double amplitude) Vibration resistance Shock resistance Life expectancy Ambient temperature 10 to 55 to 10 Hz, 0.75 mm single amplitude (1.5 mm double amplitude) Destruction 1,000 m/s2 Malfunction 100 m/s2 Mechanical 20,000,000 operations min. (at 18,000 operations/hr) Electrical 100,000 operations min. (3A at 250 VAC, 3 A at 30 VDC Resistive load) 80,000 operations min. (5 A at 250 VAC, 5 A at 30 VDC Resistive load) 100,000 operations min. (2 A at 250 VAC, 2 A at 30 VDC Inductive load) Operating -40°C to +90°C (with no icing or condensation) Humidity 5% RH to 85% RH Weight Approx. 3 g Note 1. Values in the above table are initial values. Note 2. The contact resistance is measured with 1 A applied at 5 VDC using a fall-of-potential method. Note 3. The insulation resistance is measured between coil and contacts and between contacts of the same polarity at 500 VDC. ■Engineering Data ●Durability 50 30 10 AC resistive load 5 3 2.5 500 300 100 50 250 VAC/30 VDC Resistive load 30 200 180 160 140 126 120 DC resistive load 10 1 0.5 5 0.3 3 0.1 ●Ambient Temperature vs. Maximum Coil Voltage Maximum coil voltage (%) Durability (x104 operations) Switching current (A) ●Maximum Switching Capacity 100 80 1 3 5 10 30 100 125 277 500 1,000 0 1 2 3 4 5 6 7 8 9 10 60 0 23 30 40 50 Switching current (A) Switching voltage (V) 60 70 80 90 100 Ambient temperature (°C) Note. The maximum coil voltage refers to the maximum voltage in a varying range of operating power voltage, not a continuous voltage. ● Ambient Temperature vs. Must Operate and Must Release Voltages Must operate and must release voltage (ratio of rated voltage) (%) G 6 D N Malfunction 2 ●Shock Malfunction Y 1,000 90 80 Energized 800 70 max. X min. 60 1,000 X 1,000 Z De-energized 600 400 200 50 Sample: G6DN-1A Number of Relays: 5 pcs Test conditions: Impose a shock in the ±X, ±Y, and ±Z directions three times each with the Relay energized to check the shock values that cause the Relay to malfunction. Standard:100 m/s2 40 30 20 10 0 −60 X' 1,000 Z' 1,000 max. X min. −40 −20 0 20 40 60 80 100 Ambient temperature (°C) 1,000 Y' Unit: m/s2 Shock direction X X' Y Z Z' Y' Coil terminals G6DN PCB Power Relay ■Dimensions G6DN-1A PCB Mounting Holes (Bottom View) 5.08 max. (5.05)* 20 max. (19.97)* Terminal Arrangement/ Internal Connections (Bottom View) 7.62±0.1 12.5 max. (12.45)* 7.62±0.1 Four, 1.1-dia. holes 2.54±0.1 1 2 5 8 3.3 (1.32) Two, 0.4-dia. 2.54 1.28 2-0.8 7.62 7.62 1.32 (1.28) (No coil polarity) 0.26 * Average value ■Approved Standards ●The rated values approved by each of the safety standards may be different from the performance characteristics individually defined in this datasheet. UL Recognized (File No. E41515) Model Contact form G6DN-1A SPST-NO VDE (EN61810-1) Model Coil ratings 4.5 to 24 VDC Operations 6,000 5 A at 30 VDC (Resistive) 90°C 6,000 1/10 hp 125 VAC 95°C 1,000 1/10 hp 277 VAC 95°C 1,000 D300 120 VAC/240 VAC 95°C 6,000 C300 120 VAC/240 VAC 95°C 6,000 R300 125 VDC/250 VDC 95°C 6,000 G 6 D N (Certificate No. 40042696) Contact form G6DN-1A Contact ratings 5 A at 277 VAC (Resistive) 95°C SPST-NO Coil ratings 4.5 to 24 VDC Contact ratings Operations 5 A at 250 VAC (cosφ= 1.0) 90°C 10,000 5 A at 30 VDC (L/R = 0 ms) 90°C 10,000 Clearance distance 3.5 mm min. Creepage distance 3.6 mm min. Insulation material group II Type of insulation coil-contact circuit open contact circuit Basic (PD.2) Micro disconnection Rated Insulation voltage 250 V Pollution degree 2 Rated voltage system 250 V Over voltage category II Category of protection according to IEC 61810-1 RT III (Sealed) Tracking resistance according to IEC 60112 PTI 400 V min. Flammability class according to UL94 V-0 Coil insulation system according to UL Class B ■Precautions ●Please refer to “PCB Relays Common Precautions” for correct use. 3 G6DN PCB Power Relay G 6 D N • Application examples provided in this document are for reference only. In actual applications, confirm equipment functions and safety before using the product. • Consult your OMRON representative before using the product under conditions which are not described in the manual or applying the product to nuclear control systems, railroad systems, aviation systems, vehicles, combustion systems, medical equipment, amusement machines, safety equipment, and other systems or equipment that may have a serious influence on lives and property if used improperly. Make sure that the ratings and performance characteristics of the product provide a margin of safety for the system or equipment, and be sure to provide the system or equipment with double safety mechanisms. Note: Do not use this document to operate the Unit. OMRON Corporation Electronic and Mechanical Components Company 4 Contact: www.omron.com/ecb Cat. No. K276-E1-03 0316(1115)(O)