Datasheet

G6DN
PCB Power Relay
SPST Slim Power Relay for 5 A
switching
• Slim 5-mm width and miniature size. (20 × 5.08 × 12.5 mm)
• High switching capability 5 A (250 VAC and 30 VDC), and
high contact reliability by crossbar-twin contact.
• Power consumption 110 mW of an industry top class.
• Meets application standards EN61010-1 and EN61010-2-201 for
reinforced insulation, and EN60335-1 for basic insulation.
■Model Number Legend
■Application Examples
G 6 D N -@@ @
———
•
•
•
•
1 2 3
1. Number of Poles
1: 1-pole
3. Enclosure Rating
None: Fully sealed
Programmable Controller output
Temperature Controller
Building Automation
Output of control system
G
6
D
N
2. Contact Form
A: SPST-NO (1a)
■Ordering Information
Contact form
Enclosure rating
Terminal shapes
Model
Minimum packing unit
SPST-NO (1a)
Fully sealed
PCB terminal
G6DN-1A
25 pcs/ tube
Note. When ordering, add the rated coil voltage to the model number.
Example: G6DN-1A DC5
Rated coil voltage
However, the notation of the coil voltage on the product case as well as on the packaging will be marked as @@ VDC.
Example: G6DN-1A 5VDC
■Ratings
●Coil
Rated current
(mA)
Coil resistance
(Ω)
Must operate voltage Must release voltage
(V)
(V)
% of rated voltage
Rated voltage
4.5 VDC
24.4
184
5 VDC
22.0
227
12 VDC
9.2
1,309
24 VDC
4.6
5,236
Max. voltage
(V)
70% max. *
5% min.
160%
Power consumption
(mW)
Approx. 110
Note. The rated current and resistance are measured at a coil temperature of 23°C with a tolerance of ±10%.
* Operating voltage is less than 72% when the relay is sideways and the marking is right way.
●Contacts
Resistive load
Contact Type
Inductive load (cos φ = 0.4, L/R = 7 ms)
Cross bar twin
Contact material
Ag-Alloy and Au plating *
Rated load
5 A at 250 VAC
5 A at 30 VDC
Rated carry current
5A
Max. switching voltage
277 VAC, 125 VDC
Max. switching current
5A
Min. permissible load
0.1 mA at 0.1 VDC (at 120 operations/min)
2 A at 250 VAC
2 A at 30 VDC
* Au plating is applied to stationary contact.
1
G6DN
PCB Power Relay
■Characteristics
Contact resistance
100 mΩ max.
Operate time
10 ms max.
Release time
5 ms max.
Insulation resistance
1,000 MΩ min. (at 500 VDC)
Between coil and contacts
3,000 VAC, 50/60 Hz for 1 min
Dielectric strength
Between contacts of the same
polarity
750 VAC, 50/60 Hz for 1 min
Surge withstand voltage
Between coil and contacts
6 kV (1.2 ✕ 50 μs)
Destruction
10 to 55 to 10 Hz, 2.5 mm single amplitude (5.0 mm double amplitude)
Vibration resistance
Shock resistance
Life expectancy
Ambient temperature
10 to 55 to 10 Hz, 0.75 mm single amplitude (1.5 mm double amplitude)
Destruction
1,000 m/s2
Malfunction
100 m/s2
Mechanical
20,000,000 operations min. (at 18,000 operations/hr)
Electrical
100,000 operations min. (3A at 250 VAC, 3 A at 30 VDC Resistive load)
80,000 operations min. (5 A at 250 VAC, 5 A at 30 VDC Resistive load)
100,000 operations min. (2 A at 250 VAC, 2 A at 30 VDC Inductive load)
Operating
-40°C to +90°C (with no icing or condensation)
Humidity
5% RH to 85% RH
Weight
Approx. 3 g
Note 1. Values in the above table are initial values.
Note 2. The contact resistance is measured with 1 A applied at 5 VDC using a fall-of-potential method.
Note 3. The insulation resistance is measured between coil and contacts and between contacts of the same polarity at 500 VDC.
■Engineering Data
●Durability
50
30
10
AC resistive load
5
3
2.5
500
300
100
50
250 VAC/30 VDC
Resistive load
30
200
180
160
140
126
120
DC resistive load
10
1
0.5
5
0.3
3
0.1
●Ambient Temperature vs.
Maximum Coil Voltage
Maximum coil voltage (%)
Durability (x104 operations)
Switching current (A)
●Maximum Switching Capacity
100
80
1
3
5
10
30
100 125 277 500 1,000
0
1
2
3
4
5
6
7
8
9
10
60
0
23 30
40
50
Switching current (A)
Switching voltage (V)
60
70
80
90
100
Ambient temperature (°C)
Note. The maximum coil voltage refers to the
maximum voltage in a varying range of
operating power voltage, not a continuous
voltage.
● Ambient Temperature vs. Must
Operate and Must Release Voltages
Must operate and must release voltage (ratio of rated voltage) (%)
G
6
D
N
Malfunction
2
●Shock Malfunction
Y
1,000
90
80
Energized
800
70
max.
X
min.
60
1,000
X
1,000
Z
De-energized
600
400
200
50
Sample: G6DN-1A
Number of Relays: 5 pcs
Test conditions: Impose a shock in the ±X,
±Y, and ±Z directions three times each with
the Relay energized to check the shock
values that cause the Relay to malfunction.
Standard:100 m/s2
40
30
20
10
0
−60
X'
1,000
Z'
1,000
max.
X
min.
−40
−20
0
20
40
60
80 100
Ambient temperature (°C)
1,000
Y'
Unit: m/s2
Shock direction
X
X'
Y
Z
Z'
Y'
Coil terminals
G6DN
PCB Power Relay
■Dimensions
G6DN-1A
PCB Mounting Holes
(Bottom View)
5.08 max.
(5.05)*
20 max.
(19.97)*
Terminal Arrangement/
Internal Connections
(Bottom View)
7.62±0.1
12.5 max.
(12.45)*
7.62±0.1
Four, 1.1-dia. holes
2.54±0.1
1 2
5
8
3.3
(1.32)
Two, 0.4-dia.
2.54
1.28
2-0.8
7.62
7.62
1.32
(1.28)
(No coil polarity)
0.26
* Average value
■Approved Standards
●The rated values approved by each of the safety standards may be different from the performance characteristics individually defined in
this datasheet.
UL Recognized
(File No. E41515)
Model
Contact form
G6DN-1A
SPST-NO
VDE (EN61810-1)
Model
Coil ratings
4.5 to 24 VDC
Operations
6,000
5 A at 30 VDC (Resistive) 90°C
6,000
1/10 hp 125 VAC 95°C
1,000
1/10 hp 277 VAC 95°C
1,000
D300 120 VAC/240 VAC 95°C
6,000
C300 120 VAC/240 VAC 95°C
6,000
R300 125 VDC/250 VDC 95°C
6,000
G
6
D
N
(Certificate No. 40042696)
Contact form
G6DN-1A
Contact ratings
5 A at 277 VAC (Resistive) 95°C
SPST-NO
Coil ratings
4.5 to 24 VDC
Contact ratings
Operations
5 A at 250 VAC (cosφ= 1.0) 90°C
10,000
5 A at 30 VDC (L/R = 0 ms) 90°C
10,000
Clearance distance
3.5 mm min.
Creepage distance
3.6 mm min.
Insulation material group
II
Type of insulation coil-contact circuit
open contact circuit
Basic (PD.2)
Micro disconnection
Rated Insulation voltage
250 V
Pollution degree
2
Rated voltage system
250 V
Over voltage category
II
Category of protection according to IEC 61810-1
RT III (Sealed)
Tracking resistance according to IEC 60112
PTI 400 V min.
Flammability class according to UL94
V-0
Coil insulation system according to UL
Class B
■Precautions
●Please refer to “PCB Relays Common Precautions” for correct use.
3
G6DN
PCB Power Relay
G
6
D
N
• Application examples provided in this document are for reference only. In actual applications, confirm equipment functions and safety before using the product.
• Consult your OMRON representative before using the product under conditions which are not described in the manual or applying the product to nuclear control systems, railroad
systems, aviation systems, vehicles, combustion systems, medical equipment, amusement machines, safety equipment, and other systems or equipment that may have a serious
influence on lives and property if used improperly. Make sure that the ratings and performance characteristics of the product provide a margin of safety for the system or
equipment, and be sure to provide the system or equipment with double safety mechanisms.