TDK_CXA-0492.pdf

DC-AC INVERTER UNIT
CXA-0492 (5.1W SINGLE OUTPUT)
(PRELIMINARY INFORMATION)
DESCRIPTION :
This low profile DC to AC Inverter is developed for single lamp.
APPLICABLE LCD:
Lamp Voltage 845 Vrms
Lamp Current 6.0 mArms
Lamp Start Up Voltage 2200 Vrms (Vin : 12 Vdc)
FEATURES :
Remote ON/OFF
Open Lamp Detection
Dimming Function
TEMPERATURE & HUMIDITY :
Operating Temperature Range
Storage Temperature Range
Humidity
DIMENSIONS :
LxWxH
-30°C ~ +80°C
-30°C ~ +85°C
95 %RH max
100 x 22 x 8.5 mm
Unit : mm
Weight :20 (g) typ.
Components
No.
1
2
3
Note: Please use plastic screw in case of a non-insulating mounting base!
Part Discription
PCB
Connector CN1
Connector CN2
Input side CN1:
Pin No.
Symbols
Vin
CN 1-1~2
GND
CN 1-3~4
Vrm t
CN 1-5
Vbr
CN 1-6
Rbr
CN 1-7
Vs t
CN 1-8
Qty.
1
1
1
Material
UL94V-0 (FR-4 or CEM-3)
53261-0871
SM02(8.0)B-BHS-1-TB
Note
t=1m m
Molex or equal
JST or equal
Ratings
10.8 ~ 13.2 Vdc
0 ~ 0.4=OFF/2.5 ~ Vin=ON
0 ~ 2.5 Vdc
0 ~ 50 kΏ
0 / 5 Vdc
Output side CN2:
Pin No.
Symbols
VHIGH
CN 2-1
N.C.
CN 2-2
VLOW
CN 2-3
Ratings
845 Vrm s (6.0m Arm s )
(GND)
Power Systems – The Power Solution
Web:
Email:
www.Power-Systems.de
[email protected]
All specifications are subject to change without notice.
Address: Hauptstr. 48 ; 74360 Ilsfeld-Auenstein / Germany
Tel. :
+ 49 / 70 62 / 67 59 - 6
Fax:
+ 49 / 70 62 / 67 59 - 800
Page (1)
Version 1.0, 10th August 2007
DC-AC INVERTER UNIT
CXA-0492 (5.1W SINGLE OUTPUT)
(PRELIMINARY INFORMATION)
ELECTRICAL CHARACTERISTICS :
Parameters
Output Current
Input Current
Frequency
Open Circuit Voltage
Iout
Iout
Iin1
Iin2
Iin3
F1
F2
Vopen
Vs t
Alarm Signal
Note 1 :
Symbols
Vin (V)
12±1.2
12±1.2
12±1.2
12±1.2
12±1.2
12±1.2
12±1.2
10.8
12±1.2
12±1.2
Conditions
Vbr(V) /
Tu (°C)
Rbr (kΩ)
0.0 / 0.0 -30 ~ +80
2.5 / 50 -30 ~ +80
0.0 / 0.0 -30 ~ +80
0.0 / 0.0 -30 ~ +80
0.0 / 0.0 -30 ~ +80
0.0 / 0.0 -30 ~ +80
2.5 / 50 -30 ~ +80
0.0 / 0.0 -30 ~ +80
0.0 / 0.0 -30 ~ +80
0.0 / 0.0 -30 ~ +80
Specification
Min.
Typ.
Max.
5.5
1.6
TBD
230
2050
4.5
6.0
2.6
0.59
9
55
255
2200
5.1
6.5
3.6
1.25
1
30
TBD
280
5.5
-
0
0.5
Unit
Note
m Arm s
m Arm s
m Adc
m Adc
m Adc
kHz
Hz
Vrm s
V
V
Dut y 100%
V rmt =5V
V rmt=0 V
V rmt =5V ; RL=∞
Please keep minimum of 3mm clearance (all directions) between inverter high voltage area as marked
on mechanical drawing and any conductors.
TEST CIRCUIT :
Power Systems – The Power Solution
Web:
Email:
www.Power-Systems.de
[email protected]
All specifications are subject to change without notice.
Address: Hauptstr. 48 ; 74360 Ilsfeld-Auenstein / Germany
Tel. :
+ 49 / 70 62 / 67 59 - 6
Fax:
+ 49 / 70 62 / 67 59 - 800
Page (2)