PS_PS-DA0143-291.pdf

DC-AC INVERTER UNIT
PS-DA0143-291(S) (5 W SINGLE OUTPUT)
(PRELIMINARY INFORMATION)
DESCRIPTION :
This low profile DC/AC inverter is developed for single lamps.
Optimized for Kyocera: TCG057VG1AC-H50-8X-16-20, 18th Feb. 2008
APPLICABLE LCD:
Lamp Voltage 655 Vrms
Lamp Current : 5.0 mArms
Lamp Start Up Voltage 2.400 Vrms (Vin : 12 Vdc)
FEATURES :
Current balance circuit
Extra high starting Voltage
RoHS compliant (S)
Ext. PWM Dimming
TEMPERATURE & HUMIDITY :
Operating Temperature Range
Storage Temperature Range
Humidity
DIMENSIONS :
-10°C ~ +70°C
-30°C ~ +85°C
95 %RH max
L x B x H 100 x 30 x 9 mm
Pin 1
Unit : mm
Weight :15 (g) typ.
Pin 1
Note: Please use plastic screw in case of a non-insulating mounting base!
Components
No.
1
2
3
Part Description
PCB
Connector CN1
Connector CN2
Qty.
1
1
1
Material
UL94V-0 (FR-4 or CEM-3)
S5B-PH-SM3
SM02(8.0)B-BHS-1-TB
Note
t=1mm
JST or equal
JST or equal
Power Systems – The Power Solution
Web:
Email:
www.Power-Systems.de
[email protected]
All specifications are subject to change without notice.
Address: Hauptstraße 48 ; 74360 Ilsfeld-Auenstein / Germany
Tel. :
+ 49 / 70 62 / 67 59 - 6
Fax:
+ 49 / 70 62 / 67 59 - 800
Page (1)
Version 2.0.2, 20th May 2014
DC-AC INVERTER UNIT
PS-DA0143-291(S) (5 W SINGLE OUTPUT)
Input side CN1:
Pin No. Symbols
Vin
CN 1-1
GND
CN 1-2
CN 1-3 Ext. PWM
N.C.
CN 1-4
Vrmt
CN 1-5
(PRELIMINARY INFORMATION)
Ratings
10.8~13.2 Vdc
0~1 Vdc Low / 3~5 Vdc High(L activ)
-
Output side CN2
Pin No.
Symbols
Vhigh
CN 2-1
N.C.
CN 2-2
Vlow
CN 2-3
Ratings
655Vrms (5mArms)
GND
0 ~ 0.4 = OFF / 3.0 ~ 5.5 = ON
ELECTRICAL CHARACTERISTICS :
Conditions
Parameters
Symbols
Output Current
Output Current
Input Current
Inrush Current
Frequency
Open Circuit Voltage
No Load Shotdown
Iout
Iout
Iin
Ipeak
F
Vopen
Tsd
Note 1 :
Specification
Vin (V)
Vbr (V)
Tu (°C)
Min.
Typ.
Max.
12±1.2
12±0.6
12±1.2
12±1.2
12±1.2
11.4
12±1.2
0.0
5.0
0.0
0.0
0.0
0.0
0.0
-10 ~ +70
-10 ~ +70
-10 ~ +70
-10 ~ +70
-10 ~ +70
-10 ~ +70
-10 ~ +70
4.5
-
5.0
20
0.4
5.5
0.5
1.5
70
2.700
-
50
2.200
-
60
2.400
1.0
Unit
Note
mArms
%
Adc
Adc
kHz
Vrms
sec
Duty 100%
max 6msec
wit hout load
Please keep a minimum of 2mm clearance in all directions between inverter high voltage areas
and any conductors as marked on mechanical drawing.
The external PWM-frequency should be within the range of 100 ~ 500Hz.
For other frequencies please request. The optimum frequency is normally 250 Hz and
this minimizes the interference of the vertical sync frequency.
Please provide Vcc before applying any control signals into inverter.
Revere the sequence during power off which is control signal off first then Vcc.
The input current could vary according to the parasitic capacities inside the panel.
Note 2:
Note 3:
Note 4:
TEST CIRCUIT :
F
Iin
A
Vin
10.8 ~ 13.2Vdc
SW 1
1000:1
PROBE
F
Vopen V
~
CN 1-1
SW3
V
Operation of unit
a
Operation
b
Non operation
CN 2-1
CN 1-2
Ext. PWM*
0~1V Low
3~5V High
CN 1-3
N.C.
Vrmt
2.5 ~ 5.5 Vdc
b
CN 2-2
N.C.
RL1
Iout1
CL1
CN 1-4
SW4
a
V
A
~
T1
CN 2-3
SW1
CN 1-5
Power Systems – The Power Solution
Web:
Email:
www.Power-Systems.de
[email protected]
All specifications are subject to change without notice.
Address: Hauptstraße 48 ; 74360 Ilsfeld-Auenstein / Germany
Tel. :
+ 49 / 70 62 / 67 59 - 6
Fax:
+ 49 / 70 62 / 67 59 - 800
Page (2)
Version 2.0.2, 20th May 2014