PS_PS-DA0263-02.pdf

DC-AC INVERTER UNIT
PS-DA0263-02(S) (8 W DUAL OUTPUTS)
(PRELIMINARY INFORMATION)
DESCRIPTION :
This low profile DC to AC Inverter is developed for dual lamps.
Examples for Samsung: CTM 150 XH -06A
APPLICABLE LCD:
15 to 17 inches dual lamp type
Lamp Voltage 714 Vrms
Lamp Current 2 x 6.0 mArms
Lamp Start Up Voltage 1.550 Vrms (Vin : 12 Vdc)
FEATURES :
Current Feedback Circuit
High Efficiency
Internal PWM Dimming
Regulated output current
RoHS compliant (S)
TEMPERATURE & HUMIDITY :
Operating Temperature Range
Storage Temperature Range
Humidity
DIMENSIONS :
0°C ~ +50°C
-20°C ~ +85°C
95 %RH max
L x B x H 105 x 40 x 13 mm
Pin 1
Unit : mm
Weight :25 (g) typ.
Pin 1
Pin 1
Pin 1
Note: Please use plastic screw in case of a non-insulating mounting base!
Components
No.
1
2
3
Part Description
PCB
Connector CN1
Connector CN2 ~ CN3
Qty.
1
1
2
Material
UL94V-0 (FR-4 or CEM-3)
S5B-PH-SM3-TB
SM02(8.0)B-BHS-1-TB
Input side CN1:
Pin No.
Symbols
Ratings
Vin
10.8 ~ 13.2 Vdc
CN 1-1
GND
CN 1-2
Vrm t
0 ~ 1.2 = OFF / 3.0 ~ 5.5 = ON
CN 1-3
Vbr
0 ~ 5.0 Vdc
CN 1-4
Vin
10.8 ~ 13.2 Vdc
CN 1-5
Note
t=1m m
JST or equal
JST or equal
Output side CN2 ~ CN3
Pin No.
CN 2/3-1
CN 2/3-2
Symbols
Vhigh
Vlow
Ratings
714 Vrm s (6.0 m Arm s )
(GND)
Power Systems – The Power Solution
Web:
Email:
www.Power-Systems.de
[email protected]
All specifications are subject to change without notice.
Address: Haupstr. 48 ; 74360 Ilsfeld-Auenstein / Germany
Tel. :
+ 49 / 70 62 / 67 59 - 6
Fax:
+ 49 / 70 62 / 67 59 - 800
Page (1)
Version 1.2.3, 06th September 2010
DC-AC INVERTER UNIT
PS-DA0263-02(S) (8 W DUAL OUTPUTS)
(PRELIMINARY INFORMATION)
ELECTRICAL CHARACTERISTICS :
Conditions
Parameters
Symbols
Output Current
Output Current
Input Current
Frequency
Open Circuit Voltage
Iout
Iout
Iin
F
Vopen
Note 1 :
Vin (V)
Vbr (V)
12±1.2
12±0.6
12±1.2
12±1.2
11.4
0.0
5.0
0.0
0.0
0.0
Specification
Tu (°C)
Min.
Typ.
Max.
0
0
0
0
0
5.0
40
1.350
6.0
10
60
1.550
7.0
1.0
65
2.000
~ +50
~ +50
~ +50
~ +50
~ +50
Unit
Note
m Arm s
%
Adc
kHz
Vrm s
Duty 100%
Dut y Cycle
wit hout load
Please keep minimum of 2mm clearance (all directions) between inverter high voltage area as
marked on mechanical drawing and any conductors.
Before apply any control signal into inverter, please provide Vcc first. Please follow the reversed
sequence during power off. Power off control signal first, then power off Vcc.
Note 2:
TEST CIRCUIT :
F
Vin
10.8 ~ 13.2 V
V
~
Vopen
Iin
A
1000:1
PROBE
F
CN1-1
V
CN2-1
CN1-2
CN2-2
CN1-3
V
b
SW1
Operation
b
Non operation
CL1
A
~
T1
a
Operation of unit
a
SW3
CN1-5
RL1
Vrmt
0.4 / 5 Vdc
SW 1
SW4
Iout1
SW5
CN3-1
CL1
RL1
CN1-4
Vbr
0 ~ 5.0 Vdc
CN3-2
SW6
A
~
Iout1
Power Systems – The Power Solution
Web:
Email:
www.Power-Systems.de
[email protected]
All specifications are subject to change without notice.
Address: Haupstr. 48 ; 74360 Ilsfeld-Auenstein / Germany
Tel. :
+ 49 / 70 62 / 67 59 - 6
Fax:
+ 49 / 70 62 / 67 59 - 800
Page (2)
Version 1.2.3, 06th September 2010