PS_PS-DA0207-01.pdf

DC-AC INVERTER UNIT
PS-DA0207-01(S) (6 W DUAL OUTPUTS)
(PRELIMINARY INFORMATION)
DESCRIPTION :
This low profile DC to AC Inverter is developed for dual lamps.
APPLICABLE LCD:
6.4 to 15 inches double lamp type
Lamp Voltage 500 Vrms
Lamp Current 2 x 6 mArms
Lamp Start Up Voltage 1.300 Vrms (Vin : 12 Vdc)
FEATURES :
Remote ON/OFF
Dimming Function
Open Lamp Detection
RoHS compliant (S)
TEMPERATURE & HUMIDITY :
Operating Temperature Range
Storage Temperature Range
Humidity
DIMENSIONS :
LxWxH
0°C ~ +50°C
0°C ~ +85°C
95 %RH max
113 x 30 x 9,6mm
Unit : mm
Weight :25,4 (g) typ.
Note: Please use plastic screw in case of a non-insulating mounting base!
Components
No.
1
2
3
Part Description
PCB
Connector CN1
Connector CN2 + CN3
Input side CN1:
Pin No. Symbols
Vin
CN 1-1
Vbr
CN 1-2
Vrm t
CN 1-3
GND
CN 1-4
Qty.
1
1
2
Material
UL94V-0 (FR-4 or CEM-3)
S4B-PH-SM3-TB
SM02(8.0)B-BHS-1-TB
Note
t=1m m
JST or equal
JST or equal
Output side CN2:
Ratings
12 Vdc
0 ~ 5 Vdc
0 ~ 0.4 = OFF / 4.5 ~ Vin = ON
Pin No.
CN 2-1
CN 2-2
Symbols
Vhigh
Vlow
Ratings
500 Vrm s (6 m Arm s )
(GND)
Output side CN3:
Pin No.
CN 3-1
CN 3-2
Symbols
Vhigh
Vlow
Ratings
500 Vrm s (6 m Arm s )
(GND)
Power Systems – The Power Solution
Web:
Email:
www.Power-Systems.de
[email protected]
All specifications are subject to change without notice.
Address: Hauptstr. 48 ; 74360 Ilsfeld-Auenstein / Germany
Tel. :
+ 49 / 70 62 / 67 59 - 6
Fax:
+ 49 / 70 62 / 67 59 - 800
Page (1)
Version 1.4.2, 2nd September 2010
DC-AC INVERTER UNIT
PS-DA0207-01(S) (6 W DUAL OUTPUTS)
(PRELIMINARY INFORMATION)
ELECTRICAL CHARACTERISTICS :
Parameters
Symbols
Output Current
Output Current
Input Current
Frequency
Open Circuit Voltage
Iout
Iout
Iin
F
Vopen
Ts d
No load Shutdown
Note 1 :
Conditions
Vrmt
Vin (V)
Tu (°C)
(V)
12±1.2 5±0.25 0 ~ +50
12±0.6 5±0.25 0 ~ +50
12±1.2 5±0.25 0 ~ +50
12±1.2 5±0.25 0 ~ +50
11.4
5±0.25 0 ~ +50
12±1.2
Specification
5±0.25 0 ~ +50
Unit
Note
6.5
2.1
0.6
45
1.500
m Arm s
m Arm s
Adc
kHz
Vrm s
V br = 0 V dc
-
s ec
wit hout load
Min.
Typ.
Max.
5.5
1.1
30
1.100
6.0
1.6
0.44
34
1.300
1.0
-
V br = 5 V dc
Please keep minimum of 2mm clearance (all directions) between inverter high voltage area as marked
on mechanical drawing and any conductors.
TEST CIRCUIT :
Vin
12 V
A
F
Iin
1000:1
PROBE
F
CN1-1
Vopen V
~
SW3
V
CN2-1
CN1-2
Vbr
0 ~ 5 Vdc
Vrmt
0 / 5 Vdc
A
~
T1
CN2-2
a
b
SW4
Operation of unit
a
Operation
b
Non operation
Iout1
SW5
CN1-3
V
CL1
RL1
SW 1
SW1
CN3-1
CL2
RL2
CN1-4
CN3-2
SW6
A
~
Iout2
Power Systems – The Power Solution
Web:
Email:
www.Power-Systems.de
[email protected]
All specifications are subject to change without notice.
Address: Hauptstr. 48 ; 74360 Ilsfeld-Auenstein / Germany
Tel. :
+ 49 / 70 62 / 67 59 - 6
Fax:
+ 49 / 70 62 / 67 59 - 800
Page (2)
Version 1.4.2, 2nd September 2010