Specs

JFW Industries, Inc.
Phone: 317-887-1340
[email protected]
www.jfwindustries.com
SPECIFICATION SHEET
JFW MODEL 50SA-475
SWITCH ASSEMBLY
Frequency Range
DC-12.4 GHz
Configuration
2 independent 1P2T failsafe reflective electromechanical RF switches w/ N female connectors
Enclosure Type
Benchtop
Startup/Default States
(configurable)
RF switches to port J1 at startup (see SWITCH command)
DHCP enabled (see NET command)
4 Ethernet users (see NET command)
Prompts off (see PROMPT command)
All of these default settings can be changed by user.
Unit can be configured for up to 12 Ethernet users.
Impedance
50 Ohms nominal
VSWR
1.15:1
1.20:1
1.25:1
1.35:1
1.50:1
Insertion Loss
0.15
0.20
0.25
0.35
0.50
Isolation
85
80
70
65
60
RF Input Power
(cold switched)
500
350
250
150
120
100
Switching Speed
20 milliseconds
(after command is received and processed)
(3 milliseconds typical processing time)
Manual Control
20-Button Keypad and LCD display
(IP Address configurable via keypad)
(Net mask configurable via keypad)
(Gateway configurable via keypad)
(Baud rate configurable via keypad)
Remote Control
Ethernet (DHCP, TCP/IP, 10/100, up to 12 users)
RS-232 (up to 115200 Baud)
maximum
maximum
maximum
maximum
maximum
dB
dB
dB
dB
dB
dB
dB
dB
dB
dB
DC-1 GHz
1-2 GHz
2-4 GHz
4-8 GHz
8-12.4 GHz
maximum
maximum
maximum
maximum
maximum
minimum
minimum
minimum
minimum
minimum
Watts
Watts
Watts
Watts
Watts
Watts
DC-1 GHz
1-2 GHz
2-4 GHz
4-8 GHz
8-12.4 GHz
DC-1 GHz
1-2 GHz
2-4 GHz
4-8 GHz
8-12.4 GHz
average
average
average
average
average
average
--CONTINUED-Page 1 of 2
JFW FORM E-7-F REV F
DC-0.5 GHz
0.5-1 GHz
1-2 GHz
2-4 GHz
4-8 GHz
8-12.4 GHz
JFW Industries, Inc.
Phone: 317-887-1340
[email protected]
www.jfwindustries.com
SPECIFICATION SHEET
JFW MODEL 50SA-475
SWITCH ASSEMBLY
Remote Commands
RF Switch Control Commands:
Switch, Set Switch, Read Switch, Set All Switches,
Read All Switches
System Commands:
Help, Identification, Store, Recall, Pause, Net,
Serial, Close, Disconnect, MOTD, Date, Message,
Restrict, IDENT, Name, Show Users, Reboot, Uptime,
Prompt
RF Connector
SMA female
AC Supply
100-240 VAC @ 47-63 Hz
2 Amp 5x20mm "Slo-Blo" AC fuse
Littelfuse #215-002, JFW #025-021
Operating Temperature Range
0ºC to +50ºC
Physical Size
See outline drawing 092-8105
ECR/ECN #
DATE
REV
09/29/2014
24239
Page 2 of 2
07/16/2015
APPR / DATE
ECR/ECN #
TRS 09/29/2014
A
TRS 07/16/2015
JFW FORM E-7-F REV F
DATE
REV
APPR / DATE