Specs

JFW Industries, Inc.
Phone: 317-887-1340
[email protected]
www.jfwindustries.com
SPECIFICATION SHEET
JFW MODEL 50MS-305
MATRIX SWITCH
Frequency Range
DC-6 GHz
Configuration
18 x 4 Blocking Matrix
(See block diagram 092-7410)
(maximum of 4 active RF paths)
(inputs & outputs are self-terminating*)
(all ports are bi-directional)
(the ADMIN password is located on rear panel)
Startup/Default States
(configurable)
All ports off at startup (see MATRIX command)
DHCP enabled (see NET command)
4 Ethernet users (see NET command)
Prompts off (see PROMPT command)
All of these default settings can be changed by user.
Unit can be configured for up to 12 Ethernet users.
Enclosure Type
19 inch rack mount @ 4RU high
Impedance
50 Ohms nominal
VSWR
1.2:1 typical
1.3:1 typical
1.4:1 typical
DC-2GHz
2-4GHz
4-6GHz
1.5:1 maximum
1.6:1 maximum
1.7:1 maximum
DC-2GHz
2-4GHz
4-6GHz
Insertion Loss
2.5 dB typical @ 6GHz
3.0 dB maximum DC-6GHz
Isolation
Input to Input
- 65 dB minimum
Input to Output - 65 dB minimum
Output to Output - 65 dB minimum
RF Input Power
+30 dBm average (Hot Switched)
Switching Speed
20 milliseconds
Manual Control
20-Button Keypad and LCD display
(IP Address configurable via keypad)
(Net mask configurable via keypad)
(Gateway configurable via keypad)
(Baud rate configurable via keypad)
Remote Control
Ethernet (DHCP, TCP/IP, 10/100, up to 12 users)
RS-232 (up to 115200 Baud)
--CONTINUED-Page 1 of 2
JFW FORM E-7-F REV F
JFW Industries, Inc.
Phone: 317-887-1340
[email protected]
www.jfwindustries.com
SPECIFICATION SHEET
JFW MODEL 50MS-305
MATRIX SWITCH
Remote Commands
Matrix Commands:
Matrix, Set Input, Set Output, Read Input, Read
Output, Read All Inputs, Read All Outputs, Read Matrix
Paths
System Commands:
Help, Identification, Store, Recall, Pause, Net,
Serial, Close, Disconnect, MOTD, Date, Message,
Restrict, IDENT, Name, Show Users, Reboot, Uptime,
Prompt
RF Connector
SMA female
AC Supply
100-240 VAC @ 47-63 Hz
2 Amp 5x20mm "Slo-Blo" AC fuse
Littelfuse #215-002, JFW #025-021
Temperature Range
0ºC to +50ºC
Physical Size
See outline drawing 092-7409
* The unused inputs and outputs are terminated when the unit is powered only.
If AC power is lost, all inputs and outputs are open.
ECR/ECN #
DATE
REV
07/17/2012
24239
Page 2 of 2
07/15/2015
APPR / DATE
ECR/ECN #
BAC 08/22/2012
A
TRS 07/15/2015
JFW FORM E-7-F REV F
DATE
REV
APPR / DATE