AA-1355-6.3HT The AA-1355-6.3HT filter has been designed to operate with the VICOR Harmonic Attenuator Module (HAM). This filter was specifically designed to allow the Vicor HAM and ass oc iated power conver ters to m eet Mil-Std-461D, E or F This version of the filter is configured for those applications where a chassis mount for the filter is preferred. Order P/N: AA-1355-6.3HT Operating Voltage = ___________________ 85 to 250 V Operating Current = ______________________6.3 Amp Operating Frequency = __________________50/400 Hz Operating Temperature, High = _______________ 60º C Operating Temperature, Low = _______________-40º C INSERTION LOSS vs. FREQUENCY Diel. withstanding (line - case)____1500 Vac Diel. withstanding (line - line)_____1500 Vdc Leakage Current = ___________2.5 ma @ 220 V, 60 Hz Max residual voltage after 1 sec = ________ __ 34 Volts Calculated MTBF = ________2,142,107 Hrs @ 30°C GB USA JMK Inc 15 Caldwell Dr. Amherst, NH 03031 PH: 603 886-4100 FX: 603 886-4115 email: [email protected] PH: 44-(0) 7785310729 Fax: 44-(0) 141 589 1884 EUR JMK Inc Glasgow G13 1DN Scotland UK