PDF Data Sheet Rev. B

FEATURES
FUNCTIONAL BLOCK DIAGRAM
12-bit SAR ADC
8 single-ended analog input channels
Analog input range: 0 V to 2.5 V
12-bit temperature-to-digital converter
Temperature sensor accuracy of ±1°C typical
Channel sequencer operation
Specified for VDD of 2.8 V to 3.6 V
Logic voltage VDRIVE = 1.65 V to 3.6 V
Internal 2.5 V reference
I2C-compatible serial interface supports standard and
fast speed modes
Out of range indicator/alert function
Autocycle mode
Power-down current: 12 μA maximum
Temperature range: −40°C to +125°C
20-lead LFCSP package
VDD
GND
VREF
REF
BUF
12-BIT
SUCCESSIVE
APPROXIMATION
ADC
VIN0
T/H
VIN7
INPUT
MUX
AD7291
SEQUENCER
CONTROL LOGIC
I2C INTERFACE
TEMP
SENSOR
SCL
SDA
AS1
AS0
VDRIVE
ALERT
PD/RST
08711-001
Data Sheet
8-Channel, I2C, 12-Bit SAR ADC
with Temperature Sensor
AD7291
Figure 1.
GENERAL DESCRIPTION
The AD7291 is a 12-bit, low power, 8-channel, successive
approximation analog-to-digital converter (ADC) with an
internal temperature sensor.
The part operates from a single 3.3 V power supply and features
an I2C-compatible interface. The part contains a 9-channel
multiplexer and a track-and-hold amplifier than can handle
frequencies up to 30 MHz. The device has an on-chip 2.5 V
reference that can be disabled to allow the use of an external
reference.
The AD7291 provides a 2-wire serial interface compatible with
I2C interfaces. The I2C interface supports standard and fast I2C
interface modes. The AD7291 normally remains in a partial
power-down state while not converting and powers up for
conversions. The conversion process can be controlled by a
command mode where conversions occur across I2C write
operations or an autocycle mode selected through software
control.
The AD7291 includes a high accuracy band gap temperature
sensor, which is monitored and digitized by the 12-bit ADC to
give a resolution of 0.25°C.
The AD7291 offers a programmable sequencer, which enables
the selection of a preprogrammable sequence of channels for
conversion.
On-chip limit registers can be programmed with high and low
limits for the conversion results; an out-of-range indicator
output (ALERT) becomes active when the programmed high
or low limits are violated by the conversion result. This output
can be used as an interrupt.
PRODUCT HIGHLIGHTS
1.
2.
3.
4.
5.
6.
Ideally suited to monitoring system variables in a variety
of systems including telecommunications, process control,
and industrial control.
I2C-compatible serial interface, which supports standard
and fast modes.
Automatic partial power-down while not converting to
maximize power efficiency.
Channel sequencer operation.
Integrated temperature sensor with 0.25°C resolution.
Out of range indicator that can be software disabled or
enabled.
Table 1. AD7291 and Related Products
Device
AD7291
Resolution
12-bit
Interface
I2 C
AD7298
12-bit
SPI
Features
8-channel, I2C, 12-bit SAR
ADC with temperature sensor
8-channel, 1 MSPS, 12-bit SAR
ADC with temperature sensor
Rev. B
Information furnished by Analog Devices is believed to be accurate and reliable. However, no
responsibility is assumed by Analog Devices for its use, nor for any infringements of patents or other
rights of third parties that may result from its use. Specifications subject to change without notice. No
license is granted by implication or otherwise under any patent or patent rights of Analog Devices.
Trademarks and registered trademarks are the property of their respective owners.
One Technology Way, P.O. Box 9106, Norwood, MA 02062-9106, U.S.A.
Tel: 781.329.4700
www.analog.com
Fax: 781.461.3113
©2011 Analog Devices, Inc. All rights reserved.
AD7291
Data Sheet
TABLE OF CONTENTS
Features .............................................................................................. 1
Address Pointer Register ........................................................... 15
Functional Block Diagram .............................................................. 1
Command Register (0x00)........................................................ 17
General Description ......................................................................... 1
Voltage Conversion Result Register (0x01) ............................ 18
Product Highlights ........................................................................... 1
TSENSE Conversion Result Register (0x02)................................ 18
Revision History ............................................................................... 2
TSENSE Average Result Register (0x03)...................................... 19
Specifications..................................................................................... 3
Limit Registers (0x04 to 0x1E) ................................................. 19
2
I C Timing Specifications............................................................ 5
Hysteresis Register ..................................................................... 20
Absolute Maximum Ratings............................................................ 6
Thermal Resistance ...................................................................... 6
Alert Status Register A and Alert Status Register B (0x1F and
0x20)............................................................................................. 20
ESD Caution.................................................................................. 6
I2C Interface .................................................................................... 21
Pin Configuration and Function Descriptions............................. 7
Serial Bus Address Byte ............................................................. 21
Typical Performance Characteristics ............................................. 8
General I2C Timing.................................................................... 21
Terminology .................................................................................... 11
Writing to the AD7291 .................................................................. 22
Circuit Information ........................................................................ 12
Writing Two Bytes of Data to a 16-Bit Register ..................... 22
Converter Operation.................................................................. 12
Writing to Multiple Registers.................................................... 22
Analog Input ............................................................................... 12
Reading Data From the AD7291.................................................. 23
ADC Transfer Function............................................................. 13
Reading Two Bytes of Data from a 16-Bit Register ............... 23
Temperature Sensor Operation ................................................ 13
Modes of Operation ....................................................................... 24
Temperature Sensor Averaging................................................. 13
Command Mode ........................................................................ 24
VDRIVE ............................................................................................ 14
Autocycle Mode.......................................................................... 26
The Internal or External Reference.......................................... 14
Outline Dimensions ....................................................................... 27
Reset ............................................................................................. 14
Ordering Guide .......................................................................... 27
Internal Register Structure ............................................................ 15
REVISION HISTORY
10/11—Rev. A to Rev. B
Changes to Table 9.......................................................................... 16
8/11—Rev. 0 to Rev. A
Changes to Temperature Sensor—Internal, Accuracy Parameter,
Table 2 ................................................................................................ 3
1/11—Revision 0: Initial Version
Rev. B | Page 2 of 28
Data Sheet
AD7291
SPECIFICATIONS
VDD = 2.8 V to 3.6 V; VDRIVE = 1.65 V to 3.6 V; fSCL = 400 kHz, fast SCLK mode; VREF = 2.5 V internal/external; TA = −40°C to +125°C,
unless otherwise noted.
Table 2.
Parameter
DYNAMIC PERFORMANCE
Signal-to-Noise Ratio (SNR) 2
Signal-to-Noise (+ Distortion) Ratio (SINAD)2
Total Harmonic Distortion (THD)2
Spurious-Free Dynamic Range (SFDR)
Intermodulation Distortion (IMD)
Second-Order Terms
Third-Order Terms
Channel-to-Channel Isolation
Full Power Bandwidth 3
DC ACCURACY
Resolution
Integral Nonlinearity (INL)2
Differential Nonlinearity (DNL)2
Offset Error2
Offset Error Matching2
Offset Temperature Drift
Gain Error2
Gain Error Matching2
Gain Temperature Drift
ANALOG INPUT
Input Voltage Ranges
DC Leakage Current
Input Capacitance3
REFERENCE INPUT/OUTPUT
Reference Output Voltage 4
Long-Term Stability
Output Voltage Hysteresis
Reference Input Voltage Range 5
DC Leakage Current
VREF Output Impedance
Reference Temperature Coefficient
VREF Noise3
LOGIC INPUTS (SDA, SCL)
Input High Voltage, VINH
Input Low Voltage, VINL
Input Current, IIN
Input Capacitance, CIN3
Input Hysteresis, VHYST
Min
Typ
70
70
71
71
−84
−85
Max
Unit 1
−78
−80
dB
dB
dB
dB
Test Conditions/Comments
fIN = 1 kHz sine wave
fA = 5.4 kHz, fB = 4.6 kHz
−88
−88
−100
30
10
dB
dB
dB
MHz
MHz
12
±0.5
±0.5
±2
±2.5
4
±1
±1
0.5
0
±0.01
34
8
2.4925
2.5
150
50
1
±0.01
1
12
60
±1
±0.99
±4.5
±4.5
±4
±2.5
VREF
±1
2.5075
2.5
±1
35
0.7 × VDRIVE
±0.01
6
0.3 × VDRIVE
±1
0.1 × VDRIVE
Rev. B | Page 3 of 28
Bits
LSB
LSB
LSB
LSB
ppm/°C
LSB
LSB
ppm/°C
V
μA
pF
pF
V
ppm
ppm
V
μA
Ω
ppm/°C
μV rms
V
V
μA
pF
V
fIN = 10 kHz
At 3 dB
At 0.1 dB
Guaranteed no missed codes to 12 bits
When in track
When in hold
±0.3% maximum at 25°C
For 1000 hours
External reference applied to Pin VREF
Bandwidth = 10 MHz
VIN = 0 V or VDRIVE
AD7291
Parameter
LOGIC OUTPUTS
Output High Voltage, VOH
Data Sheet
Min
Typ
VDRIVE − 0.3
VDRIVE − 0.2
Output Low Voltage, VOL
Floating State Leakage Current
Floating State Output Capacitance3
TEMPERATURE SENSOR—INTERNAL
Operating Range
Accuracy
Resolution
CONVERSION RATE
Conversion Time
Autocycle Update Rate 6
Throughput Rate
POWER REQUIREMENTS
VDD
VDRIVE
ITOTAL 7, 8
Normal Mode (Operational)
Normal Mode (Static)
Full Power-Down Mode
Power Dissipation 8
Normal Mode (Operational)
Normal Mode (Static)
Full Power-Down Mode
Max
±0.01
8
−40
±1
±1
0.25
0.4
0.6
±1
+125
±2
±3
3.2
50
2.8
1.65
Unit 1
Test Conditions/Comments
V
V
V
V
μA
pF
VDRIVE < 1.8
VDRIVE ≥ 1.8
ISINK = 3 mA
ISINK = 6 mA
°C
°C
°C
°C
22.22
μs
μs
kSPS
3
3
3.6
3.6
V
V
2.9
2.9
0.3
1.6
4.9
3.5
3.3
1.6
4.5
12
mA
mA
μA
μA
μA
8.7
10.4
10.4
1.1
5.8
17.6
10.5
12.6
11.9
5.8
16.2
43.2
mW
mW
mW
μW
μW
μW
1
TA = −40°C to +85°C
TA = 85°C to 125°C
LSB size
fSCL = 400 kHz
Digital inputs = 0 V or VDRIVE
TA = −40°C to +25°C
TA = >25°C to 85°C
TA = >85°C to 125°C
VDD = 3 V, VDRIVE = 3 V
TA = −40°C to +25°C
TA = >25°C to 85°C
TA = >85°C to 125°C
All specifications expressed in decibels are referred to full-scale input, FSR, and tested with an input signal at 0.5 dB below full scale, unless otherwise specified.
See the Terminology section.
3
Sample tested during initial release to ensure compliance.
4
Refers to Pin VREF specified for 25oC.
5
A correction factor may be required on the temperature sensor results when using an external VREF (see the Temperature Sensor Averaging section).
6
Sampled during initial release to ensure compliance; not subject to production testing.
7
ITOTAL is the total current flowing in VDD and VDRIVE.
8
ITOTAL and power dissipation are specified with VDD = VDRIVE = 3.6 V, unless otherwise noted.
2
Rev. B | Page 4 of 28
Data Sheet
AD7291
I2C TIMING SPECIFICATIONS
Guaranteed by initial characterization. All values were measured with the input filtering enabled. CB refers to the capacitive load on the
bus line, with tR and tF measured between 0.3 × VDRIVE and 0.7 × VDRIVE (see Figure 2). VDD = 2.8 V to 3.6 V; VDRIVE = 1.65 V to 3.6 V; VREF =
2.5 V internal/external; TA = −40°C to +125°C, unless otherwise noted.
Table 3.
Parameter
fSCL
t1
t2
t3
t4 1
t5
t6
t7
t8
t9
t10
t11
t11A
t12
tSP
tPOWER-UP
Min
Limit at TMIN, TMAX
Typ
Max
100
400
4
0.6
4.7
1.3
250
100
0
0
4.7
0.6
4
0.6
4.7
1.3
4
0.6
3.45
0.9
1000
300
300
300
1000
300
1000
300
300
300
50
6
20 + 0.1 CB
20 + 0.1 CB
20 + 0.1 CB
20 + 0.1 CB
20 + 0.1 CB
0
Unit
kHz
kHz
μs
μs
μs
μs
ns
ns
μs
μs
μs
μs
μs
μs
μs
μs
μs
μs
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ms
Description
Serial clock frequency
tHIGH, SCL high time
tLOW, SCL low time
tSU;DAT, data setup time
tHD;DAT, data hold time
tSU;STA, setup time for a repeated start condition
tHD;STA, hold time for a repeated start condition
tBUF, bus-free time between a stop and a start condition
tSU;STO, setup time for a stop condition
tRDA, rise time of the SDA signal
tFDA, fall time of the SDA signal
tRCL, rise time of the SCL signal
tRCL1, rise time of the SCL signal after a repeated
start condition and after an acknowledge bit
tFCL, fall time of the SCL signal
Pulse width of the suppressed spike
Power-up and acquisition time
A device must provide a data hold time for SDA to bridge the undefined region of the SCL falling edge.
t11
t12
t2
t6
SCL
t6
t4
t3
t5
t1
t8
t9
t10
SDA
t7
P
S
S
S = START CONDITION
P = STOP CONDITION
P
08711-002
1
Conditions
Standard mode
Fast mode
Standard mode
Fast mode
Standard mode
Fast mode
Standard mode
Fast mode
Standard mode
Fast mode
Standard mode
Fast mode
Standard mode
Fast mode
Standard mode
Fast mode
Standard mode
Fast mode
Standard mode
Fast mode
Standard mode
Fast mode
Standard mode
Fast mode
Standard mode
Fast mode
Standard mode
Fast mode
Fast mode
Figure 2. 2-Wire Serial Interface Timing Diagram
Rev. B | Page 5 of 28
AD7291
Data Sheet
ABSOLUTE MAXIMUM RATINGS
Table 4.
Parameter
VDD to GND1, GND
VDRIVE to GND1, GND
Analog Input Voltage to GND1
Digital Input Voltage to GND1
Digital Output Voltage to GND1
VREF to GND1
GND to GND1
Input Current to Any Pin Except Supplies 1
Operating Temperature Range
Storage Temperature Range
Junction Temperature
Pb-free Temperature, Soldering
Reflow
ESD
1
Rating
−0.3 V to +5 V
−0.3 V to +5 V
−0.3 V to +3 V
−0.3 V to VDRIVE + 0.3 V
−0.3 V to VDRIVE + 0.3 V
−0.3 V to +3 V
−0.3 V to +0.3 V
±10 mA
−40°C to +125°C
−65°C to +150°C
150°C
Stresses above those listed under Absolute Maximum Ratings
may cause permanent damage to the device. This is a stress
rating only; functional operation of the device at these or any
other conditions above those indicated in the operational
section of this specification is not implied. Exposure to absolute
maximum rating conditions for extended periods may affect
device reliability.
THERMAL RESISTANCE
Table 5. Thermal Resistance
Package Type
20-Lead LFCSP
ESD CAUTION
260(+0)°C
2 kV
Transient currents of up to 100 mA do not cause latch-up.
Rev. B | Page 6 of 28
θJA
52
θJC
6.5
Unit
°C/W
Data Sheet
AD7291
16 VDRIVE
17 PD/RST
19 VIN1
18 VIN0
20 VIN2
PIN CONFIGURATION AND FUNCTION DESCRIPTIONS
15 SCL
VIN3 1
VIN4 2
14 SDA
AD7291
VIN5 3
13 AS1
TOP VIEW
(Not to Scale)
VIN6 4
12 ALERT
11 AS0
NOTES
1. THE EXPOSED METAL PADDLE ON THE BOTTOM
OF THE LFCSP PACKAGE SHOULD BE SOLDERED
TO PCB GROUND FOR PROPER HEAT DISSIPATION
AND PERFORMANCE.
08711-003
VDD 10
GND 9
DCAP 8
VREF 7
GND1 6
VIN7 5
Figure 3. Pin Configuration
Table 6. Pin Function Descriptions
Pin No.
1 to 5,
18 to 20
6
Mnemonic
VIN3, VIN4,
VIN5, VIN6,
VIN7, VIN0,
VIN1, VIN2
GND1
7
VREF
8
DCAP
9
GND
10
11, 13
VDD
AS0, AS1
12
ALERT
14
SDA
15
SCL
16
VDRIVE
17
PD/RST
EPAD
EPAD
Description
Analog Inputs. The AD7291 has eight single-ended analog inputs that are multiplexed into the on-chip track-andhold amplifier. Each input channel can accept analog inputs from 0 V to 2.5 V. Any unused input channels should
be connected to GND1 to avoid noise pickup.
Ground. Ground reference point for the internal reference circuitry on the AD7291. All analog input signals and
the external reference signals should be referred to this GND1 voltage. The GND1 pin should be connected to the
ground plane of a system. All ground pins should ideally be at the same potential and must not be more than 0.3 V
apart, even on a transient basis. The VREF pin should be decoupled to this ground pin via a 10 μF decoupling
capacitor.
Internal Reference/External Reference Supply. The nominal internal reference voltage of 2.5 V appears at this pin.
Provided the output is buffered, the on-chip reference can be taken from this pin and applied externally to the rest
of a system. Decoupling capacitors should be connected to this pin to decouple the reference buffer. For best
performance, it is recommended to use a 10 μF decoupling capacitor on this pin to GND1. The internal reference
can be disabled and an external reference supplied to this pin if required. The input voltage range for the external
reference is 2.0 V to 2.5 V.
Decoupling Capacitor Pin. Decoupling capacitors (1 μF recommended) are connected to this pin to decouple the
internal LDO.
Ground. Ground reference point for all analog and digital circuitry on the AD7291. The GND pin should be connected to the ground plane of the system. All ground pins should ideally be at the same potential and must not be
more than 0.3 V apart, even on a transient basis. Both DCAP and VDD pins should be decoupled to this GND pin.
Supply Voltage, 2.8 V to 3.6 V. This supply should be decoupled to GND with 10 μF and 100 nF decoupling capacitors.
Logic Input. Together, the logic state of these two inputs selects a unique I2C address for the AD7291. See Table 31
for details. The device address depends on the voltage applied to these pins.
Digital Output. This pin acts as an out-of-range indicator and, if enabled, becomes active when the conversion
result violates the DATAHIGH or DATALOW register values. See the Limit Registers (0x04 to 0x1E) section.
Digital Input/Output. Serial bus bidirectional data. This open-drain output requires a pull-up resistor. The output coding
is straight binary for the voltage channels and twos complement for the temperature sensor result.
Digital Input. Serial I2C Bus Clock. This input requires a pull-up resistor. The data transfer rate in I2C mode is
compatible with both 100 kHz and 400 kHz operating modes.
Logic Power Supply Input. The voltage supplied at this pin determines the voltage at which the interface operates.
This pin should be decoupled to GND. The voltage range on this pin is 1.65 V to 3.6 V and may be less than the
voltage at VDD but should never exceed it by more than 0.3 V.
Power-Down Pin. This pin places the part into a full power-down mode and enables power conservation when
operation is not required. This pin can be used to reset the device by toggling the pin low for a minimum of 1 ns and a
maximum of 100 ns. If the maximum time is exceeded, the part enters power-down mode. When placing the device in
full power-down mode, the analog inputs must be returned to 0 V.
Exposed Paddle. The exposed metal paddle on the bottom of the LFCSP package should be soldered to PCB
ground for proper functionality and heat dissipation.
Rev. B | Page 7 of 28
AD7291
Data Sheet
TYPICAL PERFORMANCE CHARACTERISTICS
1.0
0
VDD = VDRIVE = 3V
fS = 22.22ksps
fSCL = 400kHz
fIN = 10kHz
SNR = 71.209
THD = –81.66
–40
0.8
0.6
0.4
INL (LSB)
AMPLITUDE (dB)
–20
–60
–80
TA = 25°C
VDRIVE = 3V
VDD = 3V
fS = 22.22ksps
fSCL = 400kHz
0.2
0
–0.2
–0.4
–0.6
–100
2k
4k
6k
8k
10k
–1.0
FREQUENCY (Hz)
0
0.5
1.0
Figure 4. Typical FFT
1.0
0.6
0.6
0.4
DNL (LSB)
0
–0.2
0
–0.2
–0.4
–0.6
–0.6
–0.8
–0.8
–1.0
1000
1500
2000
2500
3000
3500
4096
ADC CODE
TA = 25°C
VDRIVE = 3V
VDD = 3V
fS = 22.22ksps
fSCL = 400kHz
0.2
–0.4
500
3.0
0.8
0.2
0
2.5
1.0
DNL (POSITIVE)
DNL (NEGATIVE)
–1.0
08711-010
INL (LSB)
0.4
2.0
Figure 7. INL vs. External VREF
TA = 25°C
VDRIVE = 3V
VREF = 2.5V
VDD = 3V
fS = 22.22ksps
fSCL = 400kHz
0.8
1.5
VREF (V)
0
0.5
1.0
1.5
2.0
2.5
3.0
VREF (V)
Figure 5. Typical ADC INL
08711-013
0
08711-009
–120
08711-012
INL (POSITIVE)
INL (NEGATIVE)
–0.8
Figure 8. DNL vs. External VREF
1.0
11.7
0.8
0.2
0
–0.2
TA = 25°C
VDRIVE = 3V
VREF = 2.5V
VDD = 3V
fS = 22.22ksps
fSCL = 400kHz
–0.4
–0.6
–0.8
–1.0
0
500
1000
1500
2000
2500
3000
ADC CODE
3500
4096
08711-011
DNL (LSB)
0.4
Figure 6. Typical ADC DNL
11.6
11.5
11.4
11.3
11.2
0
0.5
1.0
1.5
2.0
EXTERNAL REFERENCE (V)
Figure 9. Effective Number of Bits vs. VREF, fSCL = 400 kHz
Rev. B | Page 8 of 28
2.5
08711-035
EFFECTIVE NUMBER OF BITS
0.6
Data Sheet
AD7291
125
CHANNEL-TO-CHANNEL ISOLATION (dB)
VDD = VDRIVE = 3V
2.5
VREF (V)
2.0
1.5
1.0
0.5
0
0.5
1.0
1.5
2.0
2.5
3.0
3.5
4.0
4.5
CURRENT LOAD (mA)
115
110
105
100
95
90
85
80
75
08711-021
0
VDD = VDRIVE = 3V
fSCL = 400kHz
120
1
100
1k
fNOISE (kHz)
Figure 10. VREF vs. Reference Output Drive
Figure 13. Channel-to-Channel Isolation, fIN = 10 kHz
55
72
VDRIVE = 3V
VDD = 3V
50
45
71
SINAD (dB)
TEMPERATURE READING (°C)
10
08711-018
3.0
40
35
70
30
0
20
40
60
80
100
TIME (Seconds)
Figure 11. Response to Thermal Shock from Room Temperature into 50°C
Stirred Oil
–90
–92
69
08711-014
20
0
0.5
1.0
1.5
2.0
2.5
EXTERNAL REFERENCE (V)
08711-036
25
Figure 14. SINAD vs. Reference Voltage, fSCL = 400 kHz, fs = 22.22 kSPS
1.5
VDD = 3V
VDRIVE = 3V
1.0
TEMPERATURE ERROR (°C)
–94
PSRR (dB)
–96
–98
–100
–102
–104
–106
0.5
0
–0.5
–1.0
–1.5
10k
100k
1M
RIPPLE FREQUENCY (Hz)
10M
100M
Figure 12. PSRR vs. Supply Ripple Frequency Without Supply Decoupling
Rev. B | Page 9 of 28
–2.0
–40
–25
–10
5
20
35
50
65
80
95
TEMPERATURE (°C)
Figure 15. Temperature Accuracy at 3 V
110 125
08711-017
–110
1k
08711-061
–108
AD7291
Data Sheet
2.5
9.0
VDRIVE = 3V
VDRIVE = 3V
VDD = 3V
8.9
2.0
TOTAL CURRENT (µA)
8.8
8.6
8.5
8.4
8.3
8.2
–40°C
+25°C
+85°C
+125°C
1.5
1.0
0.5
8.0
0
60
120
180
240
300
SCL FREQUENCY (kHz)
360
420
0
2.7
2.8
2.9
3.0
3.1
3.2
3.3
3.4
3.5
3.6
VDD
Figure 16. Power vs. Throughput in Normal Mode
Figure 17. Full Shutdown Current vs. Supply Voltage for Various
Temperatures
Rev. B | Page 10 of 28
08711-037
8.1
08711-062
POWER (mW)
8.7
Data Sheet
AD7291
TERMINOLOGY
Signal-to-Noise and Distortion Ratio (SINAD)
The measured ratio of signal-to-noise and distortion at the
output of the ADC. The signal is the rms amplitude of the
fundamental. Noise is the sum of all nonfundamental signals
up to half the sampling frequency (fS/2), excluding dc. The
ratio is dependent on the number of quantization levels in the
digitization process; the more levels, the smaller the quantization
noise. The theoretical signal-to-noise and distortion ratio for
an ideal N-bit converter with a sine wave input is given by
Signal-to-(Noise + Distortion) = (6.02 N + 1.76) dB
Thus, the SINAD is 74 dB for an ideal 12-bit converter.
Total Harmonic Distortion (THD)
The ratio of the rms sum of harmonics to the fundamental. For
the AD7291, it is defined as
THD (dB) = 20 log
V 2 2 + V 3 2 + V 4 2 + V5 2 + V6 2
Aperture Delay
The measured interval between the sampling clock’s leading
edge and the point at which the ADC takes the sample.
Aperture Jitter
This is the sample-to-sample variation in the effective point in
time at which the sample is taken.
Full-Power Bandwidth
The input frequency at which the amplitude of the reconstructed fundamental is reduced by 0.1 dB or 3 dB for a
full-scale input.
Power Supply Rejection Ratio (PSRR)
PSRR is defined as the ratio of the power in the ADC output at
full-scale frequency, f, to the power of a 100 mV p-p sine wave
applied to the ADC VDD supply of frequency, fS. The frequency
of the input varies from 5 kHz to 25 MHz.
PSRR (dB) = 10 log(Pf/PfS)
V1
where:
Pf is the power at frequency, f, in the ADC output.
PfS is the power at frequency, fS, in the ADC output.
where:
V1 is the rms amplitude of the fundamental.
V2, V3, V4, V5, and V6 are the rms amplitudes of the second
through sixth harmonics.
Peak Harmonic or Spurious Noise
The ratio of the rms value of the next largest component in the
ADC output spectrum (up to fS/2 and excluding dc) to the rms
value of the fundamental. Typically, the value of this specification
is determined by the largest harmonic in the spectrum, but for
ADCs where the harmonics are buried in the noise floor, it is a
noise peak.
Intermodulation Distortion
With inputs consisting of sine waves at two frequencies, fa and
fb, any active device with nonlinearities creates distortion
products at sum and difference frequencies of mfa ± nfb, where
m, n = 0, 1, 2, 3, and so on. Intermodulation distortion terms
are those for which neither m nor n equals zero. For example,
second-order terms include (fa + fb) and (fa − fb), while thirdorder terms include (2fa + fb), (2fa − fb), (fa + 2fb), and (fa − 2fb).
The AD7291 is tested using the CCIF standard where two input
frequencies near the top end of the input bandwidth are used.
In this case, the second-order terms are usually distanced in
frequency from the original sine waves while the third-order
terms are usually at a frequency close to the input frequencies.
As a result, the second- and third-order terms are specified
separately. The calculation of intermodulation distortion is,
like the THD specification, the ratio of the rms sum of the
individual distortion products to the rms amplitude of the sum
of the fundamentals, expressed in dB.
Integral Nonlinearity
The maximum deviation from a straight line passing through
the endpoints of the ADC transfer function. The endpoints are
zero scale, a point 1 LSB below the first code transition, and full
scale, a point 1 LSB above the last code transition.
Differential Nonlinearity
The difference between the measured and the ideal 1 LSB
change between any two adjacent codes in the ADC.
Offset Error
The deviation of the first code transition (00…000) to
(00…001) from the ideal—that is, GND1 + 1 LSB.
Offset Error Match
The difference in offset error between any two channels.
Gain Error
The deviation of the last code transition (111…110) to
(111…111) from the ideal (that is, VREF − 1 LSB) after the offset
error has been adjusted out.
Gain Error Match
The difference in gain error between any two channels.
Track-and-Hold Acquisition Time
The track-and-hold amplifier returns to track mode at the end
of conversion. Track-and-hold acquisition time is the time
required for the output of the track-and-hold amplifier to reach
its final value, within ±1 LSB, after the end of conversion.
Rev. B | Page 11 of 28
AD7291
Data Sheet
CIRCUIT INFORMATION
In command mode at the beginning of a read, the AD7291
wakes up completely, that is, becomes fully functional and
completes the conversion while the address is being read out. In
autocylce mode, conversions occur at 50 μs intervals; that is, the
AD7291 exits partial power-down mode and powers up fully at
50 μs intervals. This automatic partial power-down feature
allows power saving between conversions. Any read or write
operation across the I2C interface can occur while the device is
in partial power-down mode.
CONVERTER OPERATION
The AD7291 is a 12-bit successive approximation ADC based
around a capacitive DAC. Figure 18 and Figure 19 show simplified schematics of the ADC during the acquisition and conversion
phase, respectively. The ADC comprises control logic, SAR,
and a capacitive DAC that are used to add and subtract fixed
amounts of charge from the sampling capacitor to bring the
comparator back into a balanced condition. Figure 18 shows the
acquisition phase. SW2 is closed and SW1 is in Position A, the
comparator is held in a balanced condition, and the sampling
capacitor acquires the signal on the selected VIN channel.
CAPACITIVE
DAC
GND1
A
SW1
B
CONTROL
LOGIC
SW2
COMPARATOR
Figure 18. ADC Acquisition Phase
08711-004
VIN
CAPACITIVE
DACE
VIN
A
SW1
B
CONTROL
LOGIC
SW2
08711-005
The AD7291 typically remains in a partial power-down state
while not converting. When supplies are first applied, the part
powers up in a partial power-down state. Power-up is initiated
prior to a conversion, and the device returns to partial powerdown mode when the conversion is complete. Conversions can
be initiated by using the autocycle mode or command mode
where wake-up and a conversion occur during a write address
function. When the conversion is complete, the AD7291 again
enters partial power-down mode.
When the ADC starts a conversion (see Figure 19), SW2
opens and SW1 moves to Position B, causing the comparator
to become unbalanced. The control logic and the capacitive
DAC are used to add and subtract fixed amounts of charge to
bring the comparator back into a balanced condition. When the
comparator is rebalanced, the conversion is complete. The
control logic generates the ADC output code. Figure 21 shows
the transfer functions of the ADC.
COMPARATOR
GND1
Figure 19. ADC Conversion Phase
ANALOG INPUT
Figure 20 shows an equivalent circuit of the analog input structure of the AD7291. The two diodes, D1 and D2, provide ESD
protection for the analog inputs. Care must be taken to ensure
that the analog input signal never exceeds the internally generated
LDO voltage of 2.5 V (DCAP) by more than 300 mV. This causes
the diodes to become forward biased and start conducting
current into the substrate. The maximum current these diodes
can conduct without causing irreversible damage to the part is
10 mA. Capacitor C1, in Figure 20, is typically about 8 pF and
can primarily be attributed to pin capacitance. Resistor R1 is a
lumped component made up of the on resistance of a switch
(track-and-hold switch) and the on resistance of the input
multiplexer. The total resistance is typically about 155 Ω.
Capacitor C2 is the ADC sampling capacitor and has a
capacitance of 34 pF typically.
DCAP (2.5V)
D1
R1
C2
34pF
VIN
C1
8pF
D2
CONVERSION PHASE: SWITCH OPEN
TRACK PHASE: SWITCH CLOSED
08711-006
The AD7291 includes an 8-channel multiplexer, an on-chip
track-and-hold amplifier, an analog-to-digital converter (ADC),
an on-chip oscillator, internal data registers, an internal temperature sensor, and an I2C-compatible serial interface, all housed in
a 20-lead LFCSP. This package offers considerable space-saving
advantages over alternative solutions. The part can be operated
from a single supply from 2.8 V to 3.6 V and offers 12 bits of
resolution. The AD7291 has eight single-ended input channels
and an on-chip ±12 ppm reference. The analog input range for
the AD7921 is 0 V to VREF. The AD7291 includes a high
accuracy band gap temperature sensor, which is monitored and
digitized by the 12-bit ADC to give a resolution of 0.25°C.
Figure 20. Equivalent Analog Input Circuit
For ac applications, removing high frequency components
from the analog input signal is recommended by using an RC
low-pass filter on the relevant analog input pin. In applications
where harmonic distortion and signal-to-noise ratios are
critical, the analog input should be driven from a low impedance source. Large source impedances significantly affect the
ac performance of the ADC. This may necessitate the use of
an input buffer amplifier. The choice of the op amp is a function
of the particular application performance criteria.
Rev. B | Page 12 of 28
Data Sheet
AD7291
Each input integrates, in turn, over a period of several hundred
microseconds. This takes place continuously in the background,
leaving the user free to perform conversions on the other
channels. When integration is complete, a signal passes to the
control logic to initiate a conversion automatically.
ADC TRANSFER FUNCTION
The output coding of the AD7291 is straight binary for the
analog input channel conversion results and twos complement
for the temperature conversion result. The designed code transitions occur at successive LSB values (that is, 1 LSB, 2 LSBs,
and so forth). The LSB size is VREF/4096 for the AD7291. The
ideal transfer characteristic for the AD7291 for straight binary
coding is shown in Figure 21.
If the ADC is in command mode and performing a voltage
conversion, the AD7291 waits for it to complete and then
initiates a temperature sensor conversion. If the ADC is not
performing voltage conversions, temperature conversions occur
at 5 ms intervals.
111...111
In autocycle mode, the conversion is inserted into an
appropriate place in the current sequence. If the ADC is idle,
the conversion takes place immediately. The TSENSE conversion
result register stores the result of the last conversion on the
temperature channel; this can be read at any time.
ADC CODE
111...110
111...000
011...111
1LSB = VREF /4096
Theoretically, the temperature measuring circuit can measure
temperatures from −512°C to +511°C with a resolution of
0.25°C. However, temperatures outside TA (the specified temperature range for the AD7291) are outside the guaranteed
operating temperature range of the device. The temperature
sensor is enabled by setting the TSENSE bit in the command
register.
000...010
000...001
000...000
0V
1LSB
+VREF – 1LSB
08711-007
ANALOG INPUT
NOTES
1. VREF IS 2.5V.
Figure 21. Straight Binary Transfer Characteristic
TEMPERATURE SENSOR AVERAGING
TEMPERATURE SENSOR OPERATION
The AD7291 incorporates a temperature sensor averaging
feature to enhance the accuracy of the temperature measurements. The temperature averaging feature is performed
continuously in the background provided the TSENSE bit
in the command register is enabled. The temperature is
measured each time a TSENSE conversion is performed and a
moving average method is used to determine the result in the
TSENSE average result register. The average result is given by the
following equation:
The AD7291 contains one local temperature sensor. The on-chip,
band gap temperature sensor measures the temperature of the
AD7291 die.
The temperature sensor module on the AD7291 is based on the
three current principle (see Figure 22), where three currents are
passed through a diode and the forward voltage drop is
measured, allowing the temperature to be calculated free of
errors caused by series resistance.
4×I
8×I
IBIAS
VDD
TSENSE AVG =
7
(Previous _ Average _ Result ) + 1 (Current _ Result )
8
8
The average result is then available in the TSENSE average result
register whose content is updated after every TSENSE conversion.
VOUT+
The first TSENSE conversion result given by the AD7291 after the
temperature sensor has been selected in the command register
(Bit D7) is the actual first TSENSE conversion result, and this
result remains valid until the next TSENSE conversion is
completed and the result register is updated.
TO ADC
VOUT–
INTERNAL
SENSE
TRANSISTOR
BIAS
DIODE
08711-008
I
Figure 22. Top Level Structure of Internal Temperature Sensor
Rev. B | Page 13 of 28
AD7291
Data Sheet
Temperature Value Format
VDRIVE
One LSB of the ADC corresponds to 0.25°C. The temperature
reading from the ADC is stored in a 12-bit twos complement
format, to accommodate both positive and negative temperature measurements. Sample temperature values are listed in
Table 7. The temperature conversion formulas are as follows:
VDRIVE controls the voltage at which the serial interface operates.
VDRIVE allows the ADC to easily interface to both 1.8 V and 3 V
processors. For example, if the AD7291 is operated with a VDD
of 3.3 V, the VDRIVE pin can be powered from a 1.8 V supply.
This enables the AD7291 to operate with a larger dynamic
range with a VDD of 3.3 V while still being able to interface to
1.8 V processors. Take care to ensure that VDRIVE does not
exceed VDD by more than 0.3 V (see the Absolute Maximum
Ratings section).
Positive Temperature = ADC Code/4
Negative Temperature = (4096 − ADC Code)/4
The previous formulae are for a VREF of 2.5 V only. If an
external reference is used, the temperature sensor requires an
external reference of between 2 V and 2.5 V for correct
operation. The temperature results (in Celsius) are calculated
using the following formula, where VEXT_REF is the value of the
external reference voltage.
⎛ ADCCode
⎞
Temperature = VEXT _ REF ⎜
+ 109.3 ⎟ − 273.15
10
⎝
⎠
Table 7. Temperature Data Format
Temperature (°C)
−40
−25
−10
−0.25
0
+0.25
+10
+25
+50
+75
+100
+105
+125
Digital Output
1111 0110 0000
1111 1001 1100
1111 1101 1000
1111 1111 1111
0000 0000 0000
0000 0000 0001
0000 0010 1000
0000 0110 0100
0000 1100 1000
0001 0010 1100
0001 1001 0000
0001 1010 0100
0001 1111 0100
THE INTERNAL OR EXTERNAL REFERENCE
The AD7291 can operate with either the internal 2.5 V on-chip
reference or an externally applied reference. The EXT_REF bit
in the command register is used to determine whether the
internal reference is used. If the EXT_REF bit is selected in the
command register, an external reference can be supplied
through the VREF pin. On power-up, the internal reference is
enabled. Suitable external reference sources for the AD7291
include AD780, AD1582, ADR431, REF193, and ADR391.
The internal reference circuitry consists of a 2.5 V band gap
reference and a reference buffer. When the AD7291 operates in
internal reference mode, the 2.5 V internal reference is available
at the VREF pin, which should be decoupled to GND1 using a
10 μF capacitor. It is recommended that the internal reference
be buffered before applying it elsewhere in the system.
The internal reference is capable of sourcing up to 2 mA of
current when the converter is static. The reference buffer
requires 5.5 ms to power up and charge the 10 μF decoupling
capacitor during the power-up time.
RESET
The AD7291 includes a reset feature, which can be used to reset
the device and the content of all internal registers including the
command register to their default state. To activate the reset
operation, the PD/RST pin should be brought low for a
minimum of 1 ns and a maximum of 100 ns and be asynchronous
to the clock; therefore, it can be triggered at any time. If the PD/
RST pin is held low for greater than 100 ns, the part enters full
power-down mode. It is imperative that the PD/RST pin be held
at a stable logic level at all times to ensure normal operation.
Rev. B | Page 14 of 28
Data Sheet
AD7291
INTERNAL REGISTER STRUCTURE
The AD7291 contains 34 internal registers (see Figure 23) that
are used to store conversion results, high and low conversion
limits, and information to configure and control the device.
There are 33 data registers and one address pointer register.
COMMAND
REGISTER
VOLTAGE CONV
RESULT REGISTER
TSENSE CONV
RESULT REGISTER
Each data register has an address that the address pointer
register points to when communicating with it. Table 9 details
which registers are read, write, or read/write.
TSENSE AVG
RESULT REGISTER
CH0 DATA HIGH
REGISTER
ADDRESS POINTER REGISTER
CH0 DATA LOW
REGISTER
CH0 HYSTERESIS
REGISTER
ADDRESS
POINTER
REGISTER
Table 8. Address Pointer Register
D0
0
P5
P4
P3
P2
Register select
P1
P0
CH1 DATA LOW
REGISTER
CH1 HYSTERESIS
REGISTER
CH7 DATA HIGH
REGISTER
CH7 DATA LOW
REGISTER
CH7 HYSTERESIS
REGISTER
TSENSE DATAHIGH
REGISTER
TSENSE DATALOW
REGISTER
TSENSE HYSTERESIS
REGISTER
ALERT STATUS
REGISTER A
SDA
SCL
ALERT STATUS
REGISTER B
SERIAL BUS INTERFACE
Figure 23. AD7291 Register Structure
Rev. B | Page 15 of 28
08711-015
D1
0
CH1 DATA HIGH
REGISTER
DATA
The address pointer register is the register to which the first
data byte of every write operation is written automatically;
therefore, this register does not have and does not require an
address. The address pointer register is an 8-bit register in
which the six LSBs are used as pointer bits to store an address
that points to one of the AD7291’s data registers. The first byte
following each write address is to the address pointer register,
containing the address of one of the data registers. The six LSBs
select the data register to which subsequent data bytes are
written. Only the six LSBs of this register are used to select a
data register. During power-up, the address pointer register
contains all 0s, pointing to the command register.
AD7291
Data Sheet
Table 9. AD7291 Register Addresses
Hex Code
0x00
0x01
0x02
0x03
0x04
0x05
0x06
0x07
0x08
0x09
0x0A
0x0B
0x0C
0x0D
0x0E
0x0F
0x10
0x11
0x12
0x13
0x14
0x15
0x16
0x17
0x18
0x19
0x1A
0x1B
0x1C
0x1D
0x1E
0x1F
0x20
0x3F
P5
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
1
1
P4
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
0
1
P3
0
0
0
0
0
0
0
0
1
1
1
1
1
1
1
1
0
0
0
0
0
0
0
0
1
1
1
1
1
1
1
1
0
1
P2
0
0
0
0
1
1
1
1
0
0
0
0
1
1
1
1
0
0
0
0
1
1
1
1
0
0
0
0
1
1
1
1
0
1
P1
0
0
1
1
0
0
1
1
0
0
1
1
0
0
1
1
0
0
1
1
0
0
1
1
0
0
1
1
0
0
1
1
0
1
P0
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
Registers
Command register
Voltage conversion result register
TSENSE conversion result register
TSENSE average result register
CH0 DATAHIGH register
CH0 DATALOW register
CH0 hysteresis register
CH1 DATAHIGH register
CH1DATALOW register
CH1 hysteresis register
CH2 DATAHIGH register
CH2 DATALOW register
CH2 hysteresis register
CH3 DATAHIGH register
CH3 DATALOW register
CH3 hysteresis register
CH4 DATAHIGH register
CH4 DATALOW register
CH4 hysteresis register
CH5 DATAHIGH register
CH5 DATALOW register
CH5 hysteresis register
CH6 DATAHIGH register
CH6 DATALOW register
CH6 hysteresis register
CH7 DATAHIGH register
CH7 DATALOW register
CH7 hysteresis register
TSENSE DATAHIGH register
TSENSE DATALOW register
TSENSE hysteresis register
Alert Status Register A
Alert Status Register B
Factory test mode
Rev. B | Page 16 of 28
Read/Write
Write.
Read.
Read.
Read.
Read/write.
Read/write.
Read/write.
Read/write.
Read/write.
Read/write.
Read/write.
Read/write.
Read/write.
Read/write.
Read/write.
Read/write.
Read/write.
Read/write.
Read/write.
Read/write.
Read/write.
Read/write.
Read/write.
Read/write.
Read/write.
Read/write.
Read/write.
Read/write.
Read/write.
Read/write.
Read/write.
Read.
Read.
The user should not access this register.
Data Sheet
AD7291
COMMAND REGISTER (0x00)
The command register is a 16-bit write-only register that is used to set the operating modes of the AD7291. The bit functions are outlined
in Table 10. A two-byte write is necessary when writing to the command register. MSB denotes the first bit in the data stream. During
power-up, the default content of the command register is all 0s.
Table 10. Command Register Bits and Default Settings at Power-Up
Channel Bit
Function
Setting
MSB
D15 to DB8
CH0 to CH7
D7
TSENSE
D6
Don’t
care
Enable = 1
Disable = 0
Enable = 1
Disable = 0
0
D5
Noise-delayed
bit trial and
sampling
Enable = 1
Disable = 0
D4
EXT_REF
Enable = 1
Disable = 0
D3
Polarity of ALERT
pin (active high/
active low)
Active low = 1
Active high = 0
D2
Clear alert
D1
RESET
LSB
D0
Autocycle
mode
Enable = 1
Disable = 0
Enable = 1
Disable = 0
Enable = 1
Disable = 0
Table 11. Command Register Bit Function Descriptions
Bit
D15 to D8
Mnemonic
CH0 to CH7
D7
TSENSE
D6
D5
Don’t care
Noisedelayed bit
trial and
sampling
EXT_REF
D4
D3
D2
Polarity of
ALERT pin
Clear alert
D1
RESET
D0
Autocycle
mode
Comment
These 8-channel address bits select the analog input channel(s) to be converted. A 1 in any of Bit D15 to
Bit D8 selects a channel for conversion. If more than one channel bit is set to 1, the AD7291 sequences
through the selected channels, starting with the lowest channel. All unused channels should be set to 0. A
channel or sequence of channels for conversion must be selected in the command register, prior to initiating
a conversion.
This bit enables temperature conversions, which occur in the background at 5 ms intervals. The results can be
read from the TSENSE conversion result register (0x02) and the TSENSE average result register (0x03). For details,
refer to the Temperature Sensor Operation section.
When this function is enabled, it delays the critical sampling intervals and bit trials when there is activity on
the I2C bus, thus ensuring improved dc performance of the AD7291. When this feature is enabled, the
conversion time may vary. This bit is disabled on power-up, and it is recommended to write a 1 to enable this
feature for normal operation.
Writing a Logic 1 to this bit enables the use of an external reference. The input voltage range for the external
reference is 2 V to 2.5 V. The external reference should not exceed 2.5 V or the device performance will be
adversely affected. During power-up, the default configuration has the internal reference enabled.
This bit determines the active polarity of the ALERT pin. The ALERT pin is configured for active low operation
if this bit is set to 1 and active high if this bit is set to 0. The default configuration on power-up is active high (0).
This bit clears the content of the alert status register. Once the content of both alert status registers is cleared,
this bit should be reprogrammed to a Logic 0 to ensure that future alerts are detected.
Setting this bit resets the contents of all internal registers in the AD7291 to their default states including the
command register itself. This bit is automatically returned to 0 once the reset is completed to enable the
internal registers to be reprogrammed.
Writing a 1 to this bit enables the autocycle mode of operation. In this mode, the channels selected in Bit D15
to Bit D8 are continuously converted by the AD7291. This function is used in conjunction with the limit
registers, which can be programmed to issue an alert if the conversion result exceeds the preset limit for any
channel selected for conversion.
Rev. B | Page 17 of 28
AD7291
Data Sheet
Table 12. Channel Selection Bits for Command Register
D15
0
0
0
0
0
0
0
0
1
D14
0
0
0
0
0
0
0
1
0
D13
0
0
0
0
0
0
1
0
0
D12
0
0
0
0
0
1
0
0
0
D11
0
0
0
0
1
0
0
0
0
D10
0
0
0
1
0
0
0
0
0
D9
0
0
1
0
0
0
0
0
0
D8
0
1
0
0
0
0
0
0
0
Selected Analog Input Channel
No channel selected
Convert on Channel 7 (VIN7)
Convert on Channel 6 (VIN6)
Convert on Channel 5 (VIN5)
Convert on Channel 4 (VIN4)
Convert on Channel 3 (VIN3)
Convert on Channel 2 (VIN2)
Convert on Channel 1 (VIN1)
Convert on Channel 0 (VIN0)
D8
+64
D7
+32
Comments
If more than one channel is
selected, the AD7291 converts the
selected channels starting with the
lowest channel in the sequence.
Table 13. TSENSE Data Format
Input
Value (°C)
D11 (MSB)
−512
D10
+256
D9
+128
Sample Delay and Bit Trial Delay
D6
+16
D5
+8
D4
+4
D3
+2
D2
+1
D1
+0.5
D0 (LSB)
+0.25
Table 14. Conversion Value Register (First Read)
2
Ideally, no I C bus activity should occur while an ADC
conversion is taking place. However, this may not be possible,
for example, when operating in autocycle mode. It is therefore
recommended to enable the noise delayed bit trial and sampling
function by writing a 1 to Bit D5 in the command register. This
mechanism delays critical sample intervals and bit trials while
there is activity on the I2C bus. This results in a quiet period for
each bit decision, and conversion results are less susceptible to
interference from external noise.
On power-up, the bit trial and sample interval delay mechanism
is not enabled. It is recommended that this feature should be
enabled for normal operation. When enabled, the AD7291
delays the bit trials, mitigating against the effect of activity on
the I2C bus. In cases where there is excessive activity on the
interface lines, enabling these bits may cause the overall
conversion time to increase.
The AD7291 also incorporates functionality that allows it to
reject glitches shorter than 50 ns. This feature improves the
noise susceptibility of the device.
VOLTAGE CONVERSION RESULT REGISTER (0x01)
The voltage conversion result register is a 16-bit read-only
register that stores the conversion result from the ADC in
straight binary format. A 2-byte read is necessary to read data
from this register. Table 14 and Table 15 show the contents of
the first and second bytes of data to be read from the AD7291.
Each AD7291 conversion result consists of four channel address
bits (see Table 14 and Table 15) and the 12-bit data result.
Bit D15 to Bit D12 are the channel address bits that identify
the ADC channel that corresponds to the subsequent result.
Bit D11 to Bit D0 contain the most recent ADC result.
D15
ADD3
D14
ADD2
D13
ADD1
D12
ADD0
MSB
D11
B11
D10
B10
D9
B9
D8
B8
Table 15. Conversion Value Register (Second Read)
D7
B7
D6
B6
D5
B5
D4
B4
D3
B3
D2
B2
D1
B1
LSB
D0
B0
Table 16. Channel Address Bits for the Result Register
ADD2
0
0
0
0
0
0
0
0
1
1
ADD2
0
0
0
0
1
1
1
1
0
0
ADD1
0
0
1
1
0
0
1
1
0
0
ADD0
0
1
0
1
0
1
0
1
0
1
Analog Input Channel
VIN0
VIN1
VIN2
VIN3
VIN4
VIN5
VIN6
VIN7
TSENSE
TSENSE average result
Temperature Value Format
The temperature reading from the ADC is stored in an 11-bit
twos complement format, D11 to D0, to accommodate both
positive and negative temperature measurements. The temperature data format is provided in Table 13.
TSENSE CONVERSION RESULT REGISTER (0x02)
The TSENSE result register is a 16-bit read-only register used to
store the ADC data generated from the internal temperature
sensor. This register stores the temperature readings from the
ADC in a 12-bit twos complement format, D11 to D0, and
uses Bit D15 to Bit D12 to store the channel address bits.
Conversions take place approximately every 5 ms. Table 13
details the temperature data format that applies to the internal
temperature sensor.
Rev. B | Page 18 of 28
Data Sheet
AD7291
DATAHIGH Register
Table 17. TSENSE Conversion Result Register (First Read)
MSB
D15
ADD3
D14
ADD2
D13
ADD1
D12
ADD0
D11
B11
D10
B10
D9
B9
D8
B8
Table 18. TSENSE Result Register (Second Read)
D7
B7
D6
B6
D5
B5
D4
B4
D3
B3
D2
B2
LSB
D0
B0
D1
B1
TSENSE AVERAGE RESULT REGISTER (0x03)
The TSENSE average result register is a 16-bit read-only register
used to store the average result from the internal temperature
sensor. This register stores the average temperature readings
from the ADC in an 11-bit twos complement format, D11 to
D0, and uses Bit D15 to Bit D12 to store the channel address
bits. The TSENSE average result register is updated after every
TSENSE conversion is completed. The first TSENSE average
conversion result given by the AD7291 after averaging is
enabled is the actual first TSENSE conversion result. Table 13
details the temperature data format, which applies to the
internal temperature sensor. See the Temperature Sensor
Averaging section for more details.
D14
ADD2
D13
ADD1
D12
ADD0
D11
B11
D10
B10
D9
B9
D8
B8
Table 20. TSENSE Average Result Register (Second Read)
D7
B7
D6
B6
D5
B5
D4
B4
D3
B3
D2
B2
D1
B1
Table 21. DATAHIGH Register (First Read/Write)
MSB
D15
0
D14
0
D13
0
D12
0
D11
B11
D10
B10
D9
B9
D8
B8
Table 22. DATAHIGH Register (Second Read/Write)
D7
B7
D6
B6
D5
B5
D4
B4
D3
B3
D2
B2
D1
B1
LSB
D0
B0
DATALOW Register
Table 19. TSENSE Average Result Register (First Read)
MSB
D15
ADD3
The DATAHIGH registers for CH0 to CH7 and the internal
temperature sensor are 16-bit read/write registers; only the
12 LSBs of each register are used. Bit D15 to Bit D12 are not
used in the register and are set to 0s. This register stores the
upper limit that activates the ALERT output. If the value in the
conversion result register is greater than the value in the
DATAHIGH register, an ALERT occurs for that channel. When
the conversion result returns to a value at least N LSBs below
the DATAHIGH register value, the ALERT output pin is reset. The
value of N is taken from the hysteresis register associated with
that channel. The ALERT pin can also be reset by writing to
Bit D2 in the command register.
LSB
D0
B0
LIMIT REGISTERS (0x04 TO 0x1E)
The AD7291 has nine pairs of limit registers. Each pair stores
high and low conversion limits for each analog input channel
and the internal temperature sensor. Each pair of limit registers
has one associated hysteresis register. All 27 registers are 16 bits
wide; only the 12 LSBs of the registers are used for the AD7291.
The four MSBs, D15 and D12, in these registers should contain
0s. During power-up, the contents of the DATAHIGH register for
each analog voltage channel is full scale (0x0FFF), while the
default contents of the DATALOW voltage channels registers is
zero scale (0x0000). The output coding of the AD7291 is twos
complement for the temperature conversion result. The default
content for the TSENSE DATAHIGH register is 0x07FF, while the
default content of the TSENSE DATALOW register is 0x0800. The
AD7291 signals an alert in hardware if the conversion result
moves outside the upper or lower limit set by the limit registers.
The DATALOW register for each channel is a 16-bit read/write
register; only the 12 LSBs of each register are used. Bit D15 to
Bit D12 are not used in the register and are set to 0s. The
register stores the lower limit that activates the ALERT output.
If the value in the TSENSE conversion result register is less than
the value in the DATALOW register, an ALERT occurs for that
channel. When the conversion result returns to a value at least
N LSBs above the DATALOW register value, the ALERT output
pin is reset. The value of N is taken from the hysteresis register
associated with that channel. The ALERT output pin can also be
reset by writing to Bit D2 in the command register.
Table 23. DATALOW Register (First Read/Write)
MSB
D15
0
D14
0
D13
0
D12
0
D11
B11
D10
B10
D9
B9
D8
B8
Table 24. DATALOW Register (Second Read/Write)
D7
B7
Rev. B | Page 19 of 28
D6
B6
D5
B5
D4
B4
D3
B3
D2
B2
D1
B1
LSB
D0
B0
AD7291
Data Sheet
HYSTERESIS REGISTER
Each analog input channel and the internal temperature sensor
has its own hysteresis register, which is a 16-bit read/write
register. Only the 12 LSBs are used. Bit D15 to Bit D12 are not
used in the register and are set to 0s. The hysteresis register
stores the hysteresis value, N, when using the limit registers.
Each pair of limit registers has a dedicated hysteresis register.
The hysteresis value determines the reset point for the ALERT
pin if a violation of the limits occurs. For example, if a hysteresis
value of eight LSBs is required on the upper and lower limits of
Channel 0, the 16-bit word, 0000 0000 0000 1000, should be
written to the hysteresis register of CH0, the address of which
is 0x06 (see Table 25 and Table 26). During power-up, the
hysteresis registers content defaults to all zeros (0x0000). If a
hysteresis value is required, that value must be written to the
hysteresis register for the channel in question.
Table 25. Hysteresis Register (First Read/Write Byte)
MSB
D15
0
D14
0
D13
0
D12
0
D11
B11
D10
B10
D9
B9
D8
B8
Table 26. Hysteresis Register (Second Read/Write Byte)
D7
B7
D6
B6
D5
B5
D4
B4
D3
B3
D2
B2
D1
B1
LSB
D0
B0
ALERT STATUS REGISTER A AND ALERT STATUS
REGISTER B (0x1F AND 0x20)
The alert status registers are 16-bit, read-only registers that
provide information on an alert event. If a conversion result
activates the ALERT pin, as described in the Limit Registers
(0x04 to 0x1E) section, the alert status register can be read to
gain further information. There are two alert status registers in
the AD7291; Alert Status Register A, which stores alerts for the
analog voltage conversion channels (see Table 27 and Table 28)
and Alert Status Register B, which stores alerts for the internal
temperature sensor only (see Table 29 and Table 30).
Both alert status registers contain two status bits per channel,
one corresponding to the DATAHIGH limit and the other to the
DATALOW limit. The bit with a status of 1 shows where the
violation occurred—that is, on which channel—and whether
the violation occurred on the upper or lower limit. If a second
alert event occurs on the other channel between receiving the
first alert and interrogating the alert status register, the corresponding bit for that alert event is also set. The entire contents
of the alert status register can be cleared by writing 1 to Bit D2
in the command register.
For example, if Bit D14 in Alert Status Register A is set to 1, the
lower limit on Channel 7 (Register 0x1A) has been violated,
while if Bit D11 is set 1, the upper limit on Channel 5 has been
violated (Register 0x13).
The TSENSEHIGH and TSENSE_AVGHIGH alerts are determined
by comparison with the TSENSE DATAHIGH register (Register
0x1C). Likewise, the TSENSELOW and TSENSE_AVGLOW alerts
are determined by comparison with the TSENSE DATALOW register
(Register 0x1D).
Table 27. Alert Status Register A (First Read Byte)
D15
CH7HIGH
D14
CH7LOW
D13
CH6HIGH
D12
CH6LOW
D11
CH5HIGH
D10
CH5LOW
D9
CH4HIGH
D8
CH4LOW
D4
CH2LOW
D3
CH1HIGH
D2
CH1LOW
D1
CH0HIGH
D0
CH0LOW
D12
0
D11
0
Table 28. Alert Status Register A (Second Read Byte)
D7
CH3HIGH
D6
CH3LOW
D5
CH2HIGH
Table 29. Alert Status Register B (First Read Byte)
D15
0
D14
0
D13
0
D10
0
D9
0
D8
0
Table 30. Alert Status Register B (Second Read Byte)
D7
0
D6
0
D5
0
D4
0
D3
TSENSE_AVGHIGH
D2
TSENSE_AVGLOW
Rev. B | Page 20 of 28
D1
TSENSEHIGH
D0
TSENSELOW
Data Sheet
AD7291
I2C INTERFACE
Control of the AD7291 is carried out via the I2C compatible
serial bus. The AD7291 is connected to this bus as a slave device
under the control of a master device such as the processor.
the serial clock line (SCL) remains high. This indicates that a
data stream follows. The master device is responsible for
generating the clock.
SERIAL BUS ADDRESS BYTE
Data is sent over the serial bus in groups of nine bits—eight bits
of data from the transmitter followed by an acknowledge bit
(ACK) from the receiver. Data transitions on the SDA line must
occur during the low period of the clock signal and remain
stable during the high period. The receiver should pull the SDA
line low during the acknowledge bit to signal that the preceding
byte has been received correctly. If this is not the case, cancel
the transaction.
The first byte the user writes to the device is the slave address
byte. Similar to all I2C-compatible devices, the AD7291 has a
7-bit serial address. The three MSBs of this address are set to
010. The four LSBs are user-programmable by the three-state
input pins, AS0 and AS1, as shown in Table 31.
In Table 31, H means tie the pin to VDRIVE, L means tie the pin
to GND, and NC refers to a pin left floating. Note that in this
final case, the stray capacitance on the pin must be less than
30 pF to allow correct detection of the floating state; therefore,
any PCB trace must be kept as short as possible.
The first byte that the master sends must consist of a 7-bit slave
address, followed by a data direction bit. Each device on the
bus has a unique slave address; therefore, the first byte sets up
communication with a single slave device for the duration of the
transaction.
Table 31. Slave Address Control Using Three-State Input Pins
AS1
H
H
H
NC
NC
NC
L
L
L
Slave Address (A6 to A0)
Binary
Hex
010 0000
0x20
010 0010
0x22
010 0011
0x23
010 1000
0x28
010 1010
0x2A
010 1011
0x2B
010 1100
0x2C
010 1110
0x2E
010 1111
0x2F
AS0
H
NC
L
H
NC
L
H
NC
L
The transaction can be used either to write to a slave device
(data direction bit = 0) or to read data from it (data direction
bit = 1). In the case of a read transaction, it is often necessary
first to write to the slave device (in a separate write transaction)
to tell it from which register to read. Reading and writing
cannot be combined in one transaction.
When the transaction is complete, the master can keep control
of the bus, initiating a new transaction by generating another
start bit (high-to-low transition on SDA while SCL is high).
This is known as a repeated start (SR). Alternatively, the bus
can be relinquished by releasing the SCL line followed by the
SDA line. This low-to-high transition on SDA while SCL is high
is known as a stop bit (P), and it leaves the I2C bus in its idle
state (no current is consumed by the bus).
GENERAL I2C TIMING
Figure 24 shows the timing diagram for general read and write
operations using an I2C-compliant interface.
The example in Figure 24 shows a simple write transaction
with an AD7291 as the slave device. In this example, the
AD7291 register pointer is being set up for a future read
transaction.
When no device is driving the bus, both SCL and SDA are high.
This is known as the idle state. When the bus is idle, the master
initiates a data transfer by establishing a start condition, defined
as a high-to-low transition on the serial data line (SDA) while
SCL
A6
START COND
BY MASTER
A5
A4
A3
A2
A1
A0
SLAVE ADDRESS BYTE
R/W
P7
P6
P5
ACK. BY
AD7291
USER PROGRAMMABLE 5 LSBs
Figure 24. General I2C Timing
Rev. B | Page 21 of 28
P4
P3
P2
REGISTER ADDRESS
P1
P0
ACK. BY
AD7291
STOP BY
MASTER
08711-040
SDA
AD7291
Data Sheet
WRITING TO THE AD7291
WRITING TWO BYTES OF DATA TO A 16-BIT
REGISTER
WRITING TO MULTIPLE REGISTERS
Writing to multiple address registers consists of the following
steps (see Figure 26):
All registers on the AD7921 are 16-bit registers; therefore, two
bytes of data are required to write a value to any one of these
registers. Writing two bytes of data to a register consists of the
following sequence (see Figure 25):
5.
6.
7.
8.
9.
4.
5.
6.
7.
8.
9.
10.
11.
12.
13.
14.
15.
16.
The previous example details writing to two registers only (the
CH1 DATAHIGH register address and the command register).
However, the AD7291 can read from multiple registers in one
write operation as shown in Figure 26.
S
SLAVE ADDRESS
FROM MASTER TO SLAVE
FROM SLAVE TO MASTER
0
SA
REG POINTER
SA
DATA[15:8]
SA
DATA[7:0]
SA
S = START CONDITION
SR = REPEATED START
P = STOP CONDITION
SA = SLAVE ACKNOWLEDGE
A = NOT ACKNOWLEDGE
P
Figure 25. Writing Two Bytes of Data to a 16-Bit Register
S
SLAVE ADDRESS
...
0
SA
POINT TO COMMAND REG (0x00)
FROM MASTER TO SLAVE
FROM SLAVE TO MASTER
POINT TO CH1 DATAHIGH REG (0x04)
SA
DATA[15:8]
SA
SA
DATA[15:8]
DATA[7:0]
S = START CONDITION
SR = REPEATED START
P = STOP CONDITION
SA = SLAVE ACKNOWLEDGE
A = NOT ACKNOWLEDGE
SA
SA
DATA[7:0]
SA
...
P
08711-019
3.
4.
3.
The master device asserts a start condition on SDA.
The master sends the 7-bit slave address followed by the
write bit (low).
The addressed slave device asserts an acknowledge on SDA.
The master sends a register address. The slave asserts an
acknowledge on SDA.
The master sends the first data byte (most significant).
The slave asserts an acknowledge on SDA.
The master sends the second data byte (least significant).
The slave asserts an acknowledge on SDA.
The master asserts a stop condition on SDA to end the
transaction.
The master device asserts a start condition on SDA.
The master sends the 7-bit slave address followed by
the write bit (low).
The addressed slave device (AD7291) asserts an
acknowledge on SDA.
The master sends a register address, for example, the CH1
DATAHIGH register address.
The slave (AD7291) asserts an acknowledge on SDA.
The master sends the first data byte.
The slave (AD7291) asserts an acknowledge on SDA.
The master sends the second data byte.
The slave (AD7291) asserts an acknowledge on SDA.
The master sends a second register address, for example,
the command register.
The slave (AD7291) asserts an acknowledge on SDA.
The master sends the first data byte.
The slave (AD7291) asserts an acknowledge on SDA.
The master sends the second data byte.
The slave (AD7291) asserts an acknowledge on SDA.
The master asserts a stop condition on SDA to end the
transaction.
08711-059
1.
2.
1.
2.
Figure 26. Writing to Multiple Registers
Rev. B | Page 22 of 28
Data Sheet
AD7291
READING DATA FROM THE AD7291
READING TWO BYTES OF DATA FROM A 16-BIT
REGISTER
Reading two bytes of data from a 16-bit register consists of the
following sequence (see Figure 27):
Reading the contents from any of the 16-bit registers is a 2-byte
read operation. In this protocol, the first part of the transaction
writes to the register pointer. When the register address has
been set up, any number of reads can be performed from that
particular register without having to write to the address
pointer register again. When the required number of reads
is completed, the master should not acknowledge the final
byte. This tells the slave to stop transmitting, allowing a stop
condition to be asserted by the master. Further reads from
this register can be performed in a future transaction without
having to rewrite to the register pointer.
1.
2.
If a read from a different address is required, the relevant
register address has to be written to the address pointer register
and, again, any number of reads from this register can then be
performed. In the following example, the master device reads
three lots of 2-byte data from a slave device but as many lots
consisting of two bytes can be read as required. This protocol
assumes that the particular register address has been set up by
a single-byte write operation to the address pointer register.
SLAVE ADDRESS
...
DATA[15:8]
1
A
FROM MASTER TO SLAVE
FROM SLAVE TO MASTER
A
DATA[7:0]
DATA[15:8]
A
A
16.
DATA[7:0]
A
DATA[15:8]
A
DATA[7:0]
A
...
P
S = START CONDITION
SR = REPEATED START
P = STOP CONDITION
A = ACKNOWLEDGE
A = NOT ACKNOWLEDGE
08711-060
S
3.
4.
5.
6.
7.
8.
9.
10.
11.
12.
13.
14.
15.
The master device asserts a start condition on SDA.
The master sends the 7-bit slave address followed by the
read bit (high).
The addressed slave device asserts an acknowledge on SDA.
The master receives a data byte.
The master asserts an acknowledge on SDA.
The master receives a second data byte.
The master asserts an acknowledge on SDA.
The master receives a data byte.
The master asserts an acknowledge on SDA.
The master receives a second data byte.
The master asserts an acknowledge on SDA.
The master receives a data byte.
The master asserts an acknowledge on SDA.
The master receives a second data byte.
The master asserts a not acknowledge on SDA to notify the
slave that the data transfer is complete.
The master asserts a stop condition on SDA to end the
transaction.
Figure 27. Reading Three Lots of Two Bytes of Data from the Conversion Result Register
Rev. B | Page 23 of 28
AD7291
Data Sheet
MODES OF OPERATION
When supplies are first applied to the AD7291, the ADC
powers up in partial power-down mode and normally remains
in this partial power-down state while not converting. Once
the master addresses the AD7291, it exits partial power-down.
There are two methods of initiating a conversion on the
AD7291: command mode and autocycle mode.
COMMAND MODE
In command mode, the AD7291 converts on demand on either
a single channel or a sequence of channels. Writing in the
command register puts the part into command mode. This is
the default mode of operation and allows a conversion to be
automatically selected any time a write operation occurs to the
command register. To enter this mode, the required combination of channels is written into the command register (Register
0x00). Following the write operation, the AD7291 must be
addressed again to indicate that a read operation is required.
The read then takes place from the voltage or temperature
conversion result register. For the first conversion to occur,
the address pointer written to the AD7291 must point to the
voltage conversion result register or TSENSE conversion result
register. The conversion is completed while the first four
channel address bits are read. The next conversion in the
sequence takes place once the next read from the result
register is initiated. When operating the device in fast mode, the
acquisition and conversion times combined take approximately
4.45 μs (1.25 μs acquisition time plus 3.2 μs conversion time).
When in command mode, the part cycles through the selected
channels from the lowest selected channel in the sequence to
the next lowest until all the channels in the sequence are
converted.
To exit the command mode, the master should not acknowledge
the final byte of data. This stops the AD7291 transmitting,
allowing the master to assert a stop condition on the bus. On
the receipt of a stop condition, the AD7291 stops converting
and enters partial power-down mode, but the content of the
command register is preserved. Once the part is readdressed
and a read is initiated from the voltage conversion register, the
AD7291 begins converting on the previously selected sequence
of channels. The conversion sequence starts converting the
first selected channel in the sequence; that is, if Channel 1,
Channel 2, and Channel 3 are selected and a stop condition
occurs after the Channel 1 result is read, on resumption of
conversions, Channel 1 is reconverted and the conversion
sequence continues.
Rev. B | Page 24 of 28
Data Sheet
AD7291
15. The master then asserts an acknowledge on SDA.
16. The master receives the second data byte, which contains
the eight LSBs of the converted result for Channel VIN0. The
master then asserts on acknowledge on SDA.
17. Step 11 and Step 12 repeat for Channel VIN1 and
Channel VIN2.
18. Once the master has received the results from all the
selected channels, the slave again converts and outputs
the result for the first channel in the selected sequence.
Step 12 to Step 14 are repeated.
19. The master asserts a not acknowledge on SDA and a stop
condition on SDA to end the conversion and exit
command mode.
The example in Figure 28 shows the command mode converting on a sequence of channels including VIN0, VIN1, and VIN2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
12.
13.
14.
The master device asserts a start condition on SDA.
The master sends the 7-bit slave address followed by the
write bit (low).
The addressed slave device (AD7291) asserts an
acknowledge on SDA.
The master sends the command register address (0x00).
The slave asserts an acknowledge on SDA.
The master sends the first data byte (0xE0) to the command
register, which selects the VIN0, VIN1, and VIN2 channels.
The slave asserts an acknowledge on SDA.
The master sends the second data byte (0x20) to the command register.
The slave asserts an acknowledge on SDA.
The master sends the result register address (0x01).
The slave asserts an acknowledge on SDA.
The master sends the 7-bit slave address followed by the
write bit (high).
The slave (AD7291) asserts an acknowledge on SDA.
The master receives a data byte, which contains the
channel address bits and the four MSBs of the converted
result for Channel VIN0.
S
...
...
SLAVE ADDRESS
0
SA
POINT TO COMMAND REG (0x00)
COMMAND = 0xE0
SA
COMMAND = 0x20
*
POINT TO RESULT REG (0x01)
SA
SR
SLAVE ADDRESS
1
SA
CH AD (0000)
*
VIN0[7:0]
A
... * CH AD (0010)
...
SA
To change the conversion sequence, rewrite a new sequence to
the command mode. If a new write to the command register is
performed while an existing conversion sequence is underway,
the existing conversion sequence is terminated and the next
conversion performed is the first selected channel from the new
sequence. The maximum throughput that can be achieved using
this mode with a 400 kHz I2C clock is (400 kHz/18) = 22.2 kSPS.
VIN0[7:0]
VIN1[11:8]
CH AD (0001)
VIN1[7:0]
A
A
VIN0[11:8]
A
........
* = POSITION OF SAMPLING START
A
VIN2[7:0]
VIN2[7:0]
A
A
P
CH ID (0000)
VIN0[11:8]
A
FROM MASTER TO SLAVE
FROM SLAVE TO MASTER
Figure 28. Command Mode Operation
Rev. B | Page 25 of 28
...
...
*
VIN2[11:8]
A
SA
...
S = START CONDITION
SR = REPEATED START
P = STOP CONDITION
SA = SLAVE ACKNOWLEDGE
A = NOT ACKNOWLEDGE
08711-016
1.
2.
AD7291
Data Sheet
AUTOCYCLE MODE
The AD7291 can be configured to convert continuously on a
programmable sequence of channels, making it the ideal mode
of operation for system monitoring. This mode is useful for
monitoring signals, such as battery voltage and temperature,
alerting only when the limits are violated.
Conversions take place in the background approximately every
50 μs, and are transparent to the master. The acquisition and
conversion times combined for any channel take approximately
3.6 μs. Typically, this mode is used to automatically monitor a
selection of channels with either the limit registers programmed
to signal an out-of-range condition via the alert function or the
minimum/maximum recorders tracking the variation over time
of a particular channel. Reads and writes can be performed at
any time (the ADC voltage conversion result register, Register
0x01, contains the most recent conversion result).
During power-up, this mode is disabled. To enable this mode,
write to Bit D0 in the command register (Register 0x00) and
select the desired channels for conversion by writing to the
corresponding channel bits (Bit D15 to Bit D8). If more than
one channel bit is set in the configuration register, the ADC
automatically cycles through the channel sequence starting with
the lowest channel and working its way up through the sequence.
Once the sequence is complete, the ADC starts converting on
the lowest channel again, continuing to loop through the
sequence until this mode is exited. Once a conversion is
completed, the conversion result is compared with the content
of the limit registers, and alert status registers are automatically
updated. If a violation of the limit registers is found, the ALERT
pin is asserted with the polarity determined by Bit D3 in the
command register.
If a command mode conversion is required while the autocycle
mode is active, it is necessary to disable the autocycle mode
before proceeding to the command mode. This is achieved
by setting Bit D0 of the command register to 1. When the
command mode conversion is complete, the user can reenable
autocycle mode by setting Bit D0 to 1 in the command register.
In autocycle mode, the AD7291 does not enter partial powerdown on receipt of a stop condition; therefore, conversions and
alert monitoring continue to function.
Rev. B | Page 26 of 28
Data Sheet
AD7291
OUTLINE DIMENSIONS
0.30
0.25
0.18
0.50
BSC
PIN 1
INDICATOR
20
16
15
1
EXPOSED
PAD
2.75
2.60 SQ
2.35
11
TOP VIEW
0.80
0.75
0.70
0.50
0.40
0.30
5
10
0.25 MIN
BOTTOM VIEW
0.05 MAX
0.02 NOM
COPLANARITY
0.08
0.20 REF
SEATING
PLANE
6
FOR PROPER CONNECTION OF
THE EXPOSED PAD, REFER TO
THE PIN CONFIGURATION AND
FUNCTION DESCRIPTIONS
SECTION OF THIS DATA SHEET.
COMPLIANT TO JEDEC STANDARDS MO-220-WGGD.
020509-B
PIN 1
INDICATOR
4.10
4.00 SQ
3.90
Figure 29. 20-Lead Lead Frame Chip Scale Package [LFCSP_WQ]
4 mm × 4 mm Body, Very Very Thin Quad
(CP-20-8)
Dimensions shown in millimeters
ORDERING GUIDE
Model 1
AD7291BCPZ
AD7291BCPZ-RL7
EVAL-AD7291SDZ
1
Temperature Range
−40°C to +125°C
−40°C to +125°C
Package Description
20-Lead Lead Frame Chip Scale Package [LFCSP_WQ]
20-Lead Lead Frame Chip Scale Package [LFCSP_WQ]
Evaluation Board
Z = RoHS Compliant Part.
Rev. B | Page 27 of 28
Package Option
CP-20-8
CP-20-8
AD7291
Data Sheet
NOTES
I2C refers to a communications protocol originally developed by Philips Semiconductors (now NXP Semiconductors).
©2011 Analog Devices, Inc. All rights reserved. Trademarks and
registered trademarks are the property of their respective owners.
D08711-0-10/11(B)
Rev. B | Page 28 of 28