Test Procedure for the NCP170AMX300GEVB Evaluation Board
Test procedure:
1.Check the position of jumper and correct this if necesary in acordance with the picture above.
2. Connect the test setup as shown Figure above
3. Appy an input voltage Vin = 4.0 V
4. Appy Iout = 0mA load.
5. Check that Vout is 3.0 V +/-1%.
6. Increase Iout up to 0.15 A
7. Check that Vout is 3.0 V +/-1%.
7. Increase Vin up to 5.5 V and decrease the load in accordance with SOA
8. Power down the Load
9. Power down the Vcc
10. End of test