NCV8851-1GEVB_TEST_PROCEDURE.PDF - 177.0 KB

Test Procedure for the NCV8851-1GEVB Evaluation Board
Figure 1: Test Setup
Equipment:
Required Equipment
Equipment
Basic Specifications
Tektronix TDS 754C
Keithley 179-20A
HP 33120A Function Generator
XANTREX XHR 60-18 Dc Power Supply
Dc Power Supply
KIKUSUI PL2 72 W Electronic Load
NCV8851 Demo Board
Dual Channel Oscilloscope
DC Voltmeter 0.04% + 1 digit
180 – 250 kHz pulse at 50% duty cycle
6.5 to 40 V @ 4A
5.0 V, low current
3.5 A load at 5.0 V input
Automotive Synchronous Buck Controller
Table 1: Showing equipment needed to perform test procedures
Pin Descriptions:
Connections
Description
VIN
GND
Supply input (6.5 V to 40 V)
Ground reference
Output voltage (5.0 V)
Synchronization input
Enable input (5.0 V)
VOUT
SYNC
EN
5/7/2013
-1-
www.onsemi.com
Test Procedure:
Normal Operation
1. Connect the test setup as shown in Figure 1, but with the function generator
disconnected. Monitor switch node (SWN, tab of Q2/right side of L1)
continuously for stability (no jitter).
2. Set the power supply (VIN) to 13.2 V.
3. Set the enable input (EN) to 5.0 V.
4. Without load attached, look at SWN – the part should be switching as seen
below:
Figure 2: Switchnode in steady-state operation
5.
6.
7.
8.
Set IOUT to 100 mA.
Verify that the output voltage (VOUT) is within +/- 4% of nominal 5.0 V.
Measure the switching frequency via channel 1 (170.0 kHz +/- 10%).
Measure the switching frequency via channel 1 (170.0 kHz +/- 10%).
Verify that VOUT does not change more than approximately 0.02% (typical line
regulation).
9. Set VIN to 13.2 V and vary IOUT from 100 mA to 3.5 A. Verify that VOUT does
not change more than approximately 0.04 % (typical load regulation).
Sleep mode
1.
2.
3.
4.
While switching, bring EN low (0 V).
Ensure part shuts down (stops switching, VOUT cap discharges).
Bring EN high (5.0 V).
Check that part starts back up (starts switching, VOUT rises).
Sync function
1. Set the function generator 20 to 30 kHz higher than the switching frequency
measured in step 7 of Normal Operation.
2. Disable the generator’s output and connect it to SYNC and GND (see Figure 1).
3. While observing the oscilloscope’s waveforms (CH1 and CH2), enable the
function generator and verify that CH1 tracks CH2 (there is a delay, but they
should have the same frequency).
4. Bring function generator frequency up to 250 kHz and check that SWN tracks
frequency.
5/7/2013
-2-