RLAT_200K_Report_RH1021CMH-10_Fab_Lot_WP002452.1_W5.pdf

TID Report
11-654 111206 R1.1
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Radiation Lot Acceptance Testing (RLAT) of the RH1021CMH-10 Precision
10V Reference for Linear Technology
Customer: Linear Technology, PO# 61198L
RAD Job Number: 11-654
Part Type Tested: RH1021CMH-10 Precision 10V Reference.
Traceability Information: Fab Lot Number: WP002452.1, Wafer Number: 5, Assembly Lot Number:
677414.1, Date Code: 1125A. See photograph of unit under test in Appendix A.
Quantity of Units: 12 units received, 5 units for biased irradiation, 5 units for unbiased irradiation and 2
units for control. Serial numbers 898, 899, 900, 901 and 902 were biased during irradiation, serial
numbers 903, 904, 905, 906 and 907 were unbiased during irradiation and serial numbers 908 and 909
were used as control. See Appendix B for the radiation bias connection table.
Radiation and Electrical Test Increments: 50 to 300rad(Si)/s ionizing radiation with electrical test
increments: pre-irradiation, 20krad(Si), 50krad(Si), 100krad(Si) and 200krad(Si).
Pre-Irradiation Burn-In: Burn-In performed by Linear Technology prior to receipt by RAD
Overtest and Post-Irradiation Anneal: No overtest. No anneal.
Radiation Test Standard: MIL-STD-750E TM1019 and/or MIL-STD-883H TM1019 Condition A.
Test Hardware and Software: LTS2020 Automated Tester, Entity ID TS03, Calibration Date:
4/28/2011, Calibration Due: 4/28/2012. LTS2101 Family Board, Entity ID FB10. LTS0600 Test Fixture,
Entity ID TF03. BGSS-030309 RH1021 DUT Board. Test Program: RH102110.SRC
Facility and Radiation Source: Aeroflex RAD's Longmire Laboratories, Colorado Springs, CO.
Gamma rays provided by JLSA 81-24 Co60 source. Dosimetry performed by Air Ionization Chamber
(AIC) traceable to NIST. Aeroflex RAD's dosimetry has been audited by DSCC and Aeroflex RAD has
been awarded Laboratory Suitability for MIL-STD-750 and MIL-STD-883 TM 1019.
Irradiation and Test Temperature: Room temperature controlled to 24°C±6°C per MIL-STD-883 and
MIL-STD-750.
RLAT Result: PASSED. The units-under-test passed to the maximum
tested dose level of 200krad(Si) with all measured parameters remaining
within their datasheet specification.
An ISO 9001:2008 and DSCC Certified Company
1
TID Report
11-654 111206 R1.1
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
1.0. Overview and Background
It is well known that total dose ionizing radiation can cause parametric degradation and ultimately
functional failure in electronic devices. The damage occurs via electron-hole pair production, transport
and trapping in the dielectric and interface regions. In discrete devices the bulk of the damage is
frequently manifested as a reduction in the gain and/or breakdown voltage of the device. The damage
will usually anneal with time following the end of the radiation exposure. Due to this annealing, and to
ensure a worst-case test condition MIL-STD-883 TM1019.8 calls out a dose rate of 50 to 300rad(Si)/s as
Condition A and further specifies that the time from the end of an incremental radiation exposure and
electrical testing shall be 1-hour or less and the total time from the end of one incremental irradiation to
the beginning of the next incremental radiation step should be 2-hours or less. The work described in
this report was performed to meet MIL-STD-883 TM1019.8 Condition A.
2.0. Radiation Test Apparatus
The total ionizing dose testing described in this final report was performed using the facilities at
Aeroflex RAD's Longmire Laboratories in Colorado Springs, CO. The high dose rate total ionizing dose
(TID) source is a JLSA 81-24 irradiator modified to provide a panoramic exposure. The Co-60 rods are
held in the base of the irradiator heavily shielded by lead. During the radiation exposures the rod is
raised by an electronic timer/controller and the exposure is performed in air. The dose rate for this
irradiator in this configuration ranges from <1rad(Si)/s to a maximum of approximately 120rad(Si)/s,
determined by the distance from the source. For high-dose rate experiments the bias boards are placed in
a radial fashion equidistant from the raised Co-60 rods with the distance adjusted to provide the required
dose rate. The irradiator calibration is maintained by Aeroflex RAD Longmire Laboratories using air
ionization chamber (AIC) equipment calibrated with traceability to the National Institute of Standards
and Technology (NIST). Figure 2.1 shows a photograph of the JLSA 81-24 Co-60 irradiator at
Aeroflex RAD's Longmire Laboratory facility.
Aeroflex RAD is currently certified by the Defense Supply Center Columbus (DSCC) for Laboratory
Suitability under MIL STD 750 and MIL-STD-883. Additional details regarding Aeroflex RAD
dosimetry for TM1019 Condition A testing are available in Aeroflex RAD's report to DSCC entitled:
"Dose Rate Mapping of the J.L. Shepherd and Associates Model 81 Irradiator Installed by Radiation
Assured Devices".
An ISO 9001:2008 and DSCC Certified Company
2
TID Report
11-654 111206 R1.1
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Figure 2.1. Aeroflex RAD's high dose rate Co-60 irradiator. The dose rate is obtained by positioning the deviceunder-test at a fixed distance from the gamma cell. The dose rate for this irradiator varies from approximately
120rad(Si)/s close to the rods down to 1rad(Si)/s at a distance of approximately 2-feet.
An ISO 9001:2008 and DSCC Certified Company
3
TID Report
11-654 111206 R1.1
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
3.0. Radiation Test Conditions
The RH1021CMH-10 Precision 10V Reference described in this final report were irradiated using a split
15V supply and with all pins tied to ground, that is biased and unbiased. See the TID Bias Table in
Appendix B for the full bias circuits. In our opinion, this bias circuit satisfies the requirements of MILSTD-883H TM1019.8 Section 3.9.3 Bias and Loading Conditions which states "The bias applied to the
test devices shall be selected to produce the greatest radiation induced damage or the worst-case damage
for the intended application, if known. While maximum voltage is often worst case some bipolar linear
device parameters (e.g. input bias current or maximum output load current) exhibit more degradation
with 0 V bias."
The devices were irradiated to a maximum total ionizing dose level of 200krad(Si) with incremental
readings at 20krad(Si), 50krad(Si) and 100krad(Si). Electrical testing occurred within one hour
following the end of each irradiation segment. For intermediate irradiations, the parts were tested and
returned to total dose exposure within two hours from the end of the previous radiation increment.
The TID bias board was positioned in the Co-60 cell to provide the required minimum of 50rad(Si)/s
and was located inside a lead-aluminum enclosure. The lead-aluminum enclosure is required under MILSTD-883H TM1019.8 Section 3.4 that reads as follows: "Lead/Aluminum (Pb/Al) container. Test
specimens shall be enclosed in a Pb/Al container to minimize dose enhancement effects caused by lowenergy, scattered radiation. A minimum of 1.5 mm Pb, surrounding an inner shield of at least 0.7 mm
Al, is required. This Pb/Al container produces an approximate charged particle equilibrium for Si and
for TLDs such as CaF2. The radiation field intensity shall be measured inside the Pb/Al container (1)
initially, (2) when the source is changed, or (3) when the orientation or configuration of the source,
container, or test-fixture is changed. This measurement shall be performed by placing a dosimeter (e.g.,
a TLD) in the device-irradiation container at the approximate test-device position. If it can be
demonstrated that low energy scattered radiation is small enough that it will not cause dosimetry errors
due to dose enhancement, the Pb/Al container may be omitted."
The final dose rate within the high dose rate lead-aluminum enclosure was determined using calibration
calculations based on air ionization chamber (AIC) dosimetry performed just prior to beginning the total
dose irradiations. The final dose rate for this work was 65.85rad(Si)/s with a precision of ±5%.
An ISO 9001:2008 and DSCC Certified Company
4
TID Report
11-654 111206 R1.1
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
4.0. Tested Parameters
During the total ionizing dose characterization testing the following electrical parameters were measured
pre- and post-irradiation:
1.
2.
3.
4.
5.
6.
7.
Supply Current (A) @ VIN=15V, IOUT=0
Output Voltage (V) @ VIN=15V, IOUT=0
Line Regulation (ppm/V) @ 11.5V ≤ VIN ≤ 14.5V
Line Regulation (ppm/V) @ 14.5V < VIN ≤ 40V
Sourcing Load Regulation (ppm/mA) @ 0 ≤ IOUT ≤ 10mA
Sinking Load Regulation (ppm/mA) @ 1.7 ≤ IOUT ≤ 10mA
Minimum Current (Shunt Mode) (A) @ VIN is Open
Appendix C details the measured parameters, test conditions, pre-irradiation specification and
measurement resolution for each of the measurements.
The parametric data was obtained as "read and record" and all the raw data plus an attributes summary
are contained in this report as well as in a separate Excel file. The attributes data contains the average,
standard deviation and the average with the KTL values applied. The KTL value used in this work is
2.742 per MIL-HDBK-814 using one sided tolerance limits of 90/90 and a 5-piece sample size. The
90/90 KTL values were selected to match the statistical levels specified in the MIL-PRF-38535
sampling plan for the qualification of a radiation hardness assured (RHA) component. Note that the
following criteria must be met for a device to pass the total ionizing dose test: following the radiation
exposure each of the 5 pieces irradiated under electrical bias shall pass the specification value. The units
irradiated without electrical bias and the KTL statistics are included in this report for reference only. If
any of the 5 pieces irradiated under electrical bias exceed the device post radiation data sheet
specification limits, then the lot could be logged as a failure.
An ISO 9001:2008 and DSCC Certified Company
5
TID Report
11-654 111206 R1.1
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
5.0. Total Ionizing Dose Test Results
Based on this criterion the RH1021CMH-10 Precision 10V Reference (from the lot traceability
information provided on the first page of this test report) PASSED the total ionizing dose test to the
maximum tested dose level of 200krad(Si) with all measured parameters remaining within their
datasheet specifications.
Figures 5.1 through 5.7 show plots of all the measured parameters versus total ionizing dose while
Tables 5.1 - 5.7 show the corresponding raw data for each of these parameters. In the data plots the solid
diamonds are the average of the measured data points for the sample irradiated under electrical bias
while the shaded diamonds are the average of the measured data points for the units irradiated with all
pins tied to ground. The black lines (solid or dashed) are the average of the data points after application
of the KTL statistics on the sample irradiated in the biased condition while the shaded lines (solid or
dashed) are the average of the data points after application of the KTL statistics on the sample irradiated
in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or
maximum specification value as defined in the datasheet and/or test plan.
The control units, as expected, show no significant changes to any of the parameters. Therefore we can
conclude that the electrical testing remained in control throughout the duration of the tests and the
observed degradation was due to the radiation exposure. Appendix D lists the figures used in this section
to facilitate the location of a particular parameter.
An ISO 9001:2008 and DSCC Certified Company
6
TID Report
11-654 111206 R1.1
Average Biased
Average Un-Biased
Ps90%/90% (+KTL) Un-Biased
Specification MAX
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Ps90%/90% (+KTL) Biased
Supply Current (A) @ VIN=15V, IOUT=0
1.80E-03
1.60E-03
1.40E-03
1.20E-03
1.00E-03
8.00E-04
6.00E-04
4.00E-04
2.00E-04
0.00E+00
0
50
100
150
200
Total Dose (krad(Si))
Figure 5.1. Plot of Supply Current (A) @ VIN=15V, IOUT=0 versus total dose. The solid diamonds are the
average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are
the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines
(solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples
irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after
application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the
pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test
plan.
An ISO 9001:2008 and DSCC Certified Company
7
TID Report
11-654 111206 R1.1
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Table 5.1. Raw data for Supply Current (A) @ VIN=15V, IOUT=0 versus total dose, including the statistical
analysis, specification and the status of the testing (pass/fail).
Total Dose (krad(Si))
Supply Current (A) @ VIN=15V, IOUT=0
Device
0
20
50
100
200
898 1.08E-03 1.10E-03 1.08E-03 1.08E-03 1.06E-03
899 1.06E-03 1.06E-03 1.06E-03 1.05E-03 1.03E-03
900 1.06E-03 1.07E-03 1.05E-03 1.03E-03 1.05E-03
901 1.05E-03 1.08E-03 1.04E-03 1.04E-03 1.01E-03
902 1.04E-03 1.06E-03 1.05E-03 1.04E-03 1.03E-03
903 1.07E-03 1.07E-03 1.07E-03 1.04E-03 1.04E-03
904 1.04E-03 1.07E-03 1.03E-03 1.03E-03 1.02E-03
905 1.03E-03 1.06E-03 1.05E-03 1.05E-03 1.04E-03
906 1.05E-03 1.05E-03 1.05E-03 1.03E-03 1.00E-03
907 1.04E-03 1.05E-03 1.04E-03 1.04E-03 1.01E-03
908 1.06E-03 1.07E-03 1.05E-03 1.08E-03 1.06E-03
909 1.06E-03 1.07E-03 1.07E-03 1.07E-03 1.09E-03
Biased Statistics
Average Biased
1.06E-03 1.07E-03 1.06E-03 1.05E-03 1.03E-03
Std Dev Biased
1.38E-05 1.61E-05 1.72E-05 1.74E-05 1.94E-05
Ps90%/90% (+KTL) Biased
1.10E-03 1.12E-03 1.10E-03 1.09E-03 1.09E-03
Ps90%/90% (-KTL) Biased
1.02E-03 1.03E-03 1.01E-03 9.99E-04 9.81E-04
Un-Biased Statistics
Average Un-Biased
1.05E-03 1.06E-03 1.05E-03 1.04E-03 1.02E-03
Std Dev Un-Biased
1.51E-05 8.85E-06 1.61E-05 9.52E-06 1.54E-05
Ps90%/90% (+KTL) Un-Biased
1.09E-03 1.08E-03 1.09E-03 1.06E-03 1.06E-03
Ps90%/90% (-KTL) Un-Biased
1.00E-03 1.04E-03 1.00E-03 1.01E-03 9.79E-04
Specification MAX
1.70E-03 1.70E-03 1.70E-03 1.70E-03 1.70E-03
Status
PASS
PASS
PASS
PASS
PASS
An ISO 9001:2008 and DSCC Certified Company
8
TID Report
11-654 111206 R1.1
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Average Biased
Average Un-Biased
Ps90%/90% (-KTL) Biased
Ps90%/90% (-KTL) Un-Biased
Ps90%/90% (+KTL) Biased
Ps90%/90% (+KTL) Un-Biased
Specification MIN
Specification MAX
Output Voltage (V) @ VIN=15V, IOUT=0
1.00E+01
1.00E+01
1.00E+01
1.00E+01
1.00E+01
1.00E+01
1.00E+01
9.99E+00
9.99E+00
9.98E+00
9.98E+00
0
50
100
150
200
Total Dose (krad(Si))
Figure 5.2. Plot of Output Voltage (V) @ VIN=15V, IOUT=0 versus total dose. The solid diamonds are the
average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are
the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines
(solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples
irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after
application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the
pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test
plan.
An ISO 9001:2008 and DSCC Certified Company
9
TID Report
11-654 111206 R1.1
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Table 5.2. Raw data for Output Voltage (V) @ VIN=15V, IOUT=0 versus total dose, including the statistical
analysis, specification and the status of the testing (pass/fail).
Total Dose (krad(Si))
Output Voltage (V) @ VIN=15V, IOUT=0
Device
0
20
50
100
200
898 9.998E+00
1.00E+01
9.99E+00
9.99E+00
9.99E+00
899 9.998E+00
9.99E+00
9.99E+00
9.99E+00
9.99E+00
900 9.998E+00
1.00E+01
9.99E+00
9.99E+00
9.99E+00
901 1.000E+01
1.00E+01
1.00E+01
9.99E+00
9.99E+00
902 1.000E+01
1.00E+01
1.00E+01
9.99E+00
9.99E+00
903 1.000E+01
1.00E+01
1.00E+01
1.00E+01
1.00E+01
904 1.000E+01
1.00E+01
1.00E+01
1.00E+01
1.00E+01
905 1.000E+01
1.00E+01
1.00E+01
1.00E+01
1.00E+01
906 9.999E+00
1.00E+01
1.00E+01
1.00E+01
1.00E+01
907 9.999E+00
1.00E+01
1.00E+01
1.00E+01
1.00E+01
908 9.998E+00
1.00E+01
1.00E+01
1.00E+01
1.00E+01
909 9.999E+00
1.00E+01
1.00E+01
1.00E+01
1.00E+01
Biased Statistics
Average Biased
1.00E+01
1.00E+01
9.99E+00
9.99E+00
9.99E+00
Std Dev Biased
1.39E-03
1.16E-03
1.07E-03
1.04E-03
9.86E-04
Ps90%/90% (+KTL) Biased
1.00E+01
1.00E+01
1.00E+01
1.00E+01
9.99E+00
Ps90%/90% (-KTL) Biased
1.00E+01
9.99E+00
9.99E+00
9.99E+00
9.99E+00
Un-Biased Statistics
Average Un-Biased
1.00E+01
1.00E+01
1.00E+01
1.00E+01
1.00E+01
Std Dev Un-Biased
7.26E-04
7.14E-04
7.33E-04
7.98E-04
8.90E-04
Ps90%/90% (+KTL) Un-Biased
1.00E+01
1.00E+01
1.00E+01
1.00E+01
1.00E+01
Ps90%/90% (-KTL) Un-Biased
1.00E+01
1.00E+01
1.00E+01
1.00E+01
1.00E+01
Specification MIN
9.995E+00 9.990E+00 9.987E+00 9.985E+00 9.980E+00
Status
PASS
PASS
PASS
PASS
PASS
Specification MAX
1.0005E+01 1.0010E+01 1.0013E+01 1.0015E+01 1.0020E+01
Status
PASS
PASS
PASS
PASS
PASS
An ISO 9001:2008 and DSCC Certified Company
10
Line Regulation (ppm/V) @ 11.5V ≤ VIN ≤ 14.5V
TID Report
11-654 111206 R1.1
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Average Biased
Average Un-Biased
Ps90%/90% (-KTL) Biased
Ps90%/90% (-KTL) Un-Biased
Ps90%/90% (+KTL) Biased
Ps90%/90% (+KTL) Un-Biased
Specification MIN
Specification MAX
8.00E+00
6.00E+00
4.00E+00
2.00E+00
0.00E+00
-2.00E+00
-4.00E+00
-6.00E+00
-8.00E+00
0
50
100
150
200
Total Dose (krad(Si))
Figure 5.3. Plot of Line Regulation (ppm/V) @ 11.5V ≤ VIN ≤ 14.5V versus total dose. The solid diamonds are
the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds
are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines
(solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples
irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after
application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the
pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test
plan.
An ISO 9001:2008 and DSCC Certified Company
11
TID Report
11-654 111206 R1.1
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Table 5.3. Raw data for Line Regulation (ppm/V) @ 11.5V ≤ VIN ≤ 14.5V versus total dose, including the
statistical analysis, specification and the status of the testing (pass/fail).
Line Regulation (ppm/V) @ 11.5V ≤ VIN ≤ 14.5V
Device
898
899
900
901
902
903
904
905
906
907
908
909
Biased Statistics
Average Biased
Std Dev Biased
Ps90%/90% (+KTL) Biased
Ps90%/90% (-KTL) Biased
Un-Biased Statistics
Average Un-Biased
Std Dev Un-Biased
Ps90%/90% (+KTL) Un-Biased
Ps90%/90% (-KTL) Un-Biased
Specification MIN
Status
Specification MAX
Status
0
-6.50E-01
-2.90E-01
-6.90E-01
-6.30E-01
-1.10E-01
-1.90E-01
-5.90E-01
-3.90E-01
-4.00E-01
-4.80E-01
2.30E-01
1.33E+00
Total
20
6.00E-01
-4.80E-01
-3.90E-01
-5.20E-01
-5.20E-01
-6.60E-01
-1.00E+00
-2.70E-01
-1.50E-01
2.50E-01
7.20E-01
1.86E+00
Dose (krad(Si))
50
100
2.40E-01 -7.90E-01
1.70E-01 -7.20E-01
2.80E-01 -8.70E-01
-3.60E-01 -1.11E+00
-4.40E-01 -4.30E-01
4.10E-01 -1.86E+00
3.10E-01 -1.66E+00
1.00E-02 -7.80E-01
-9.50E-01 -1.60E-01
-4.20E-01 -4.00E-02
1.40E-01 -2.40E-01
0.00E+00 7.00E-02
200
-1.06E+00
-8.10E-01
-1.36E+00
-1.79E+00
-9.40E-01
-3.00E-02
-3.00E-01
-8.30E-01
-9.60E-01
6.80E-01
-2.80E-01
5.10E-01
-4.74E-01 -2.62E-01 -2.20E-02 -7.84E-01 -1.19E+00
2.59E-01 4.85E-01 3.48E-01 2.47E-01 3.91E-01
2.36E-01 1.07E+00 9.33E-01 -1.08E-01 -1.19E-01
-1.18E+00 -1.59E+00 -9.77E-01 -1.46E+00 -2.27E+00
-4.10E-01
1.47E-01
-7.48E-03
-8.13E-01
-4.00E+00
PASS
4.00E+00
PASS
-3.66E-01
4.81E-01
9.52E-01
-1.68E+00
-4.00E+00
PASS
4.00E+00
PASS
-1.28E-01
5.62E-01
1.41E+00
-1.67E+00
-4.50E+00
PASS
4.50E+00
PASS
An ISO 9001:2008 and DSCC Certified Company
12
-9.00E-01
8.37E-01
1.39E+00
-3.19E+00
-5.00E+00
PASS
5.00E+00
PASS
-2.88E-01
6.61E-01
1.53E+00
-2.10E+00
-6.00E+00
PASS
6.00E+00
PASS
Line Regulation (ppm/V) @ 14.5V < VIN ≤ 40V
TID Report
11-654 111206 R1.1
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Average Biased
Average Un-Biased
Ps90%/90% (-KTL) Biased
Ps90%/90% (-KTL) Un-Biased
Ps90%/90% (+KTL) Biased
Ps90%/90% (+KTL) Un-Biased
Specification MIN
Specification MAX
4.00E+00
3.00E+00
2.00E+00
1.00E+00
0.00E+00
-1.00E+00
-2.00E+00
-3.00E+00
-4.00E+00
0
50
100
150
200
Total Dose (krad(Si))
Figure 5.4. Plot of Line Regulation (ppm/V) @ 14.5V < VIN ≤ 40V versus total dose. The solid diamonds are the
average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are
the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines
(solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples
irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after
application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the
pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test
plan.
An ISO 9001:2008 and DSCC Certified Company
13
TID Report
11-654 111206 R1.1
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Table 5.4. Raw data for Line Regulation (ppm/V) @ 14.5V < VIN ≤ 40V versus total dose, including the
statistical analysis, specification and the status of the testing (pass/fail).
Line Regulation (ppm/V) @ 14.5V < VIN ≤ 40V
Device
898
899
900
901
902
903
904
905
906
907
908
909
Biased Statistics
Average Biased
Std Dev Biased
Ps90%/90% (+KTL) Biased
Ps90%/90% (-KTL) Biased
Un-Biased Statistics
Average Un-Biased
Std Dev Un-Biased
Ps90%/90% (+KTL) Un-Biased
Ps90%/90% (-KTL) Un-Biased
Specification MIN
Status
Specification MAX
Status
0
-4.70E-01
-5.80E-01
-4.50E-01
-4.20E-01
-3.70E-01
-5.10E-01
-5.30E-01
-4.30E-01
-3.10E-01
-5.10E-01
-4.80E-01
-4.10E-01
Total
20
-6.70E-01
-6.00E-01
-3.40E-01
-5.50E-01
-6.10E-01
-6.40E-01
-5.80E-01
-4.60E-01
-4.10E-01
-6.40E-01
-5.20E-01
-4.60E-01
Dose (krad(Si))
50
100
-6.50E-01 -6.20E-01
-6.20E-01 -6.30E-01
-5.90E-01 -6.50E-01
-5.10E-01 -4.80E-01
-4.90E-01 -6.60E-01
-5.90E-01 -6.30E-01
-5.70E-01 -5.30E-01
-5.80E-01 -4.60E-01
-4.20E-01 -5.30E-01
-5.90E-01 -7.30E-01
-5.40E-01 -5.40E-01
-5.70E-01 -5.30E-01
200
-6.80E-01
-6.60E-01
-5.40E-01
-6.50E-01
-4.40E-01
-5.80E-01
-5.80E-01
-6.50E-01
-4.20E-01
-5.00E-01
-5.10E-01
-6.20E-01
-4.58E-01 -5.54E-01 -5.72E-01 -6.08E-01 -5.94E-01
7.79E-02 1.27E-01 6.94E-02 7.33E-02 1.02E-01
-2.44E-01 -2.06E-01 -3.82E-01 -4.07E-01 -3.15E-01
-6.72E-01 -9.02E-01 -7.62E-01 -8.09E-01 -8.73E-01
-4.58E-01
9.12E-02
-2.08E-01
-7.08E-01
-2.00E+00
PASS
2.00E+00
PASS
-5.46E-01
1.06E-01
-2.56E-01
-8.36E-01
-2.00E+00
PASS
2.00E+00
PASS
-5.50E-01
7.31E-02
-3.49E-01
-7.51E-01
-2.00E+00
PASS
2.00E+00
PASS
An ISO 9001:2008 and DSCC Certified Company
14
-5.76E-01
1.05E-01
-2.87E-01
-8.65E-01
-2.00E+00
PASS
2.00E+00
PASS
-5.46E-01
8.82E-02
-3.04E-01
-7.88E-01
-3.00E+00
PASS
3.00E+00
PASS
Sourcing Load Regulation (ppm/mA) @ 0 ≤ IOUT ≤ 10mA
TID Report
11-654 111206 R1.1
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Average Biased
Average Un-Biased
Ps90%/90% (-KTL) Biased
Ps90%/90% (-KTL) Un-Biased
Ps90%/90% (+KTL) Biased
Ps90%/90% (+KTL) Un-Biased
Specification MIN
Specification MAX
3.00E+01
2.00E+01
1.00E+01
0.00E+00
-1.00E+01
-2.00E+01
-3.00E+01
0
50
100
150
200
Total Dose (krad(Si))
Figure 5.5. Plot of Sourcing Load Regulation (ppm/mA) @ 0 ≤ IOUT ≤ 10mA versus total dose. The solid
diamonds are the average of the measured data points for the samples irradiated under electrical bias while the
shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to
ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL
statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average
of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The
red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in
the datasheet and/or test plan.
An ISO 9001:2008 and DSCC Certified Company
15
TID Report
11-654 111206 R1.1
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Table 5.5. Raw data for Sourcing Load Regulation (ppm/mA) @ 0 ≤ IOUT ≤ 10mA versus total dose, including
the statistical analysis, specification and the status of the testing (pass/fail).
Sourcing Load Regulation (ppm/mA) @ 0 ≤ IOUT ≤ 10mA
Device
898
899
900
901
902
903
904
905
906
907
908
909
Biased Statistics
Average Biased
Std Dev Biased
Ps90%/90% (+KTL) Biased
Ps90%/90% (-KTL) Biased
Un-Biased Statistics
Average Un-Biased
Std Dev Un-Biased
Ps90%/90% (+KTL) Un-Biased
Ps90%/90% (-KTL) Un-Biased
Specification MIN
Status
Specification MAX
Status
0
-1.53E+01
-1.46E+01
-1.42E+01
-1.43E+01
-1.47E+01
-1.52E+01
-1.50E+01
-1.53E+01
-1.41E+01
-1.51E+01
-1.46E+01
-1.46E+01
Total Dose (krad(Si))
20
50
100
-1.50E+01 -1.52E+01 -1.53E+01
-1.50E+01 -1.46E+01 -1.53E+01
-1.44E+01 -1.44E+01 -1.50E+01
-1.48E+01 -1.47E+01 -1.44E+01
-1.48E+01 -1.48E+01 -1.54E+01
-1.50E+01 -1.49E+01 -1.54E+01
-1.53E+01 -1.56E+01 -1.54E+01
-1.47E+01 -1.55E+01 -1.52E+01
-1.42E+01 -1.48E+01 -1.47E+01
-1.48E+01 -1.49E+01 -1.49E+01
-1.47E+01 -1.45E+01 -1.52E+01
-1.44E+01 -1.44E+01 -1.48E+01
-1.46E+01 -1.48E+01 -1.47E+01 -1.51E+01 -1.54E+01
4.10E-01 2.68E-01 3.07E-01 3.88E-01 3.32E-01
-1.35E+01 -1.41E+01 -1.39E+01 -1.40E+01 -1.45E+01
-1.58E+01 -1.55E+01 -1.56E+01 -1.62E+01 -1.63E+01
-1.49E+01
4.62E-01
-1.37E+01
-1.62E+01
-2.50E+01
PASS
2.50E+01
PASS
-1.48E+01
4.02E-01
-1.37E+01
-1.59E+01
-2.50E+01
PASS
2.50E+01
PASS
-1.51E+01
3.84E-01
-1.41E+01
-1.62E+01
-2.50E+01
PASS
2.50E+01
PASS
An ISO 9001:2008 and DSCC Certified Company
16
200
-1.56E+01
-1.59E+01
-1.50E+01
-1.53E+01
-1.54E+01
-1.61E+01
-1.56E+01
-1.53E+01
-1.47E+01
-1.53E+01
-1.48E+01
-1.45E+01
-1.51E+01
3.10E-01
-1.43E+01
-1.60E+01
-2.50E+01
PASS
2.50E+01
PASS
-1.54E+01
4.97E-01
-1.40E+01
-1.67E+01
-2.50E+01
PASS
2.50E+01
PASS
Sinking Load Regulation (ppm/mA) @ 1.7 ≤ IOUT ≤ 10mA
TID Report
11-654 111206 R1.1
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Average Biased
Average Un-Biased
Ps90%/90% (-KTL) Biased
Ps90%/90% (-KTL) Un-Biased
Ps90%/90% (+KTL) Biased
Ps90%/90% (+KTL) Un-Biased
Specification MIN
Specification MAX
2.00E+02
1.50E+02
1.00E+02
5.00E+01
0.00E+00
-5.00E+01
-1.00E+02
-1.50E+02
-2.00E+02
0
50
100
150
200
Total Dose (krad(Si))
Figure 5.6. Plot of Sinking Load Regulation (ppm/mA) @ 1.7 ≤ IOUT ≤ 10mA versus total dose. The solid
diamonds are the average of the measured data points for the samples irradiated under electrical bias while the
shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to
ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL
statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average
of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The
red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in
the datasheet and/or test plan.
An ISO 9001:2008 and DSCC Certified Company
17
TID Report
11-654 111206 R1.1
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Table 5.6. Raw data for Sinking Load Regulation (ppm/mA) @ 1.7 ≤ IOUT ≤ 10mA versus total dose, including
the statistical analysis, specification and the status of the testing (pass/fail).
Sinking Load Regulation (ppm/mA) @ 1.7 ≤ IOUT ≤ 10mA
Device
898
899
900
901
902
903
904
905
906
907
908
909
Biased Statistics
Average Biased
Std Dev Biased
Ps90%/90% (+KTL) Biased
Ps90%/90% (-KTL) Biased
Un-Biased Statistics
Average Un-Biased
Std Dev Un-Biased
Ps90%/90% (+KTL) Un-Biased
Ps90%/90% (-KTL) Un-Biased
Specification MIN
Status
Specification MAX
Status
0
2.43E+01
2.31E+01
2.39E+01
2.47E+01
2.73E+01
2.55E+01
2.58E+01
2.75E+01
2.68E+01
2.72E+01
2.64E+01
2.59E+01
Total
20
2.51E+01
2.20E+01
2.31E+01
2.45E+01
2.62E+01
2.47E+01
2.32E+01
2.62E+01
2.32E+01
2.56E+01
2.45E+01
2.36E+01
Dose (krad(Si))
50
100
2.39E+01 2.56E+01
2.23E+01 2.30E+01
2.31E+01 2.38E+01
2.57E+01 2.63E+01
2.62E+01 2.73E+01
2.52E+01 2.63E+01
2.50E+01 2.54E+01
2.68E+01 2.77E+01
2.61E+01 2.71E+01
2.58E+01 2.69E+01
2.59E+01 2.57E+01
2.44E+01 2.46E+01
200
2.62E+01
2.60E+01
2.52E+01
2.81E+01
2.94E+01
2.86E+01
2.70E+01
2.94E+01
2.87E+01
2.90E+01
2.51E+01
2.49E+01
2.46E+01
1.58E+00
2.90E+01
2.03E+01
2.42E+01
1.66E+00
2.87E+01
1.96E+01
2.42E+01
1.66E+00
2.88E+01
1.97E+01
2.52E+01
1.77E+00
3.01E+01
2.04E+01
2.70E+01
1.70E+00
3.17E+01
2.23E+01
2.66E+01
8.68E-01
2.89E+01
2.42E+01
-1.00E+02
PASS
1.00E+02
PASS
2.46E+01
1.34E+00
2.82E+01
2.09E+01
-1.00E+02
PASS
1.00E+02
PASS
2.58E+01
7.05E-01
2.77E+01
2.39E+01
-1.00E+02
PASS
1.00E+02
PASS
2.67E+01
8.56E-01
2.90E+01
2.43E+01
-1.00E+02
PASS
1.00E+02
PASS
2.85E+01
8.97E-01
3.10E+01
2.61E+01
-1.50E+02
PASS
1.50E+02
PASS
An ISO 9001:2008 and DSCC Certified Company
18
TID Report
11-654 111206 R1.1
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Average Biased
Average Un-Biased
Ps90%/90% (+KTL) Biased
Ps90%/90% (+KTL) Un-Biased
Minimum Current (Shunt Mode) (A) @ VIN is Open
Specification MAX
1.60E-03
1.40E-03
1.20E-03
1.00E-03
8.00E-04
6.00E-04
4.00E-04
2.00E-04
0.00E+00
0
50
100
150
200
Total Dose (krad(Si))
Figure 5.7. Plot of Minimum Current (Shunt Mode) (A) @ VIN is Open versus total dose. The solid diamonds
are the average of the measured data points for the samples irradiated under electrical bias while the shaded
diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The
black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the
samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data
points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted
line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the
datasheet and/or test plan.
An ISO 9001:2008 and DSCC Certified Company
19
TID Report
11-654 111206 R1.1
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Table 5.7. Raw data for Minimum Current (Shunt Mode) (A) @ VIN is Open versus total dose, including the
statistical analysis, specification and the status of the testing (pass/fail).
Total Dose (krad(Si))
Minimum Current (Shunt Mode) (A) @ VIN is Open
Device
0
20
50
100
200
898 8.77E-04 8.86E-04 8.83E-04 8.88E-04 8.94E-04
899 8.63E-04 8.66E-04 8.66E-04 8.70E-04 8.68E-04
900 8.62E-04 8.72E-04 8.70E-04 8.72E-04 8.79E-04
901 8.70E-04 8.62E-04 8.57E-04 8.62E-04 8.62E-04
902 8.47E-04 8.59E-04 8.57E-04 8.60E-04 8.62E-04
903 8.66E-04 8.73E-04 8.70E-04 8.74E-04 8.70E-04
904 8.53E-04 8.63E-04 8.56E-04 8.62E-04 8.62E-04
905 8.46E-04 8.57E-04 8.58E-04 8.60E-04 8.60E-04
906 8.53E-04 8.55E-04 8.53E-04 8.57E-04 8.55E-04
907 8.53E-04 8.59E-04 8.57E-04 8.61E-04 8.60E-04
908 8.58E-04 8.65E-04 8.56E-04 8.64E-04 8.65E-04
909 8.75E-04 8.77E-04 8.81E-04 8.82E-04 8.82E-04
Biased Statistics
Average Biased
8.64E-04 8.69E-04 8.67E-04 8.70E-04 8.73E-04
Std Dev Biased
1.12E-05 1.07E-05 1.08E-05 1.11E-05 1.36E-05
Ps90%/90% (+KTL) Biased
8.94E-04 8.98E-04 8.96E-04 9.01E-04 9.10E-04
Ps90%/90% (-KTL) Biased
8.33E-04 8.40E-04 8.37E-04 8.40E-04 8.36E-04
Un-Biased Statistics
Average Un-Biased
8.54E-04 8.61E-04 8.59E-04 8.63E-04 8.61E-04
Std Dev Un-Biased
7.26E-06 7.13E-06 6.53E-06 6.53E-06 5.46E-06
Ps90%/90% (+KTL) Un-Biased
8.74E-04 8.81E-04 8.77E-04 8.81E-04 8.76E-04
Ps90%/90% (-KTL) Un-Biased
8.34E-04 8.42E-04 8.41E-04 8.45E-04 8.46E-04
Specification MAX
1.50E-03 1.50E-03 1.50E-03 1.50E-03 1.50E-03
Status
PASS
PASS
PASS
PASS
PASS
An ISO 9001:2008 and DSCC Certified Company
20
TID Report
11-654 111206 R1.1
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
6.0. Summary / Conclusions
The total ionizing dose testing described in this final report was performed using the facilities at
Aeroflex RAD's Longmire Laboratories in Colorado Springs, CO. The high dose rate total ionizing dose
(TID) source is a JLSA 81-24 irradiator modified to provide a panoramic exposure. The Co-60 rods are
held in the base of the irradiator heavily shielded by lead, during the radiation exposures the rod is raised
by an electronic timer/controller and the exposure is performed in air. The dose rate for this irradiator in
this configuration ranges from <1rad(Si)/s to a maximum of approximately 120rad(Si)/s, determined by
the distance from the source.
The parametric data was obtained as "read and record" and all the raw data plus an attributes summary
are contained in this report as well as in a separate Excel file. The attributes data contains the average,
standard deviation and the average with the KTL values applied. The KTL value used in this work is
2.742 per MIL-HDBK-814 using one sided tolerance limits of 90/90 and a 5-piece sample size. The
90/90 KTL values were selected to match the statistical levels specified in the MIL-PRF-38535
sampling plan for the qualification of a radiation hardness assured (RHA) component. Note that the
following criteria must be met for a device to pass the total ionizing dose test: following the radiation
exposure each of the 5 pieces irradiated under electrical bias shall pass the specification value. The units
irradiated without electrical bias and the KTL statistics are included in this report for reference only. If
any of the 5 pieces irradiated under electrical bias exceed the device post radiation data sheet
specification limits, then the lot could be logged as a failure.
Based on this criterion the RH1021CMH-10 Precision 10V Reference (from the lot date code identified
on the first page of this test report) PASSED the total ionizing dose test to the maximum tested dose
level of 200krad(Si) with all measured parameters remaining within their datasheet specifications.
An ISO 9001:2008 and DSCC Certified Company
21
TID Report
11-654 111206 R1.1
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Appendix A: Photograph of Packing Label and a Sample Unit-Under-Test to Show Part
Traceability
An ISO 9001:2008 and DSCC Certified Company
22
TID Report
11-654 111206 R1.1
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Appendix B: Radiation Bias Connections and Absolute Maximum Ratings
TID Radiation Biased Conditions:
Pin Function
Connection / Bias
1
NC
2
VIN
3
NC
4
GND
5
TRIM
NC
To 15V,
0.1µF decoupling to pin 4
NC
To -15V,
0.1µF decoupling to pin 2
NC
6
VOUT
NC
7
NC
NC
8
NC
NC
TID Radiation Unbiased Conditions:
Pin Function Connection / Bias
1
NC
GND
2
VIN
GND
3
NC
GND
4
GND
GND
5
TRIM
GND
6
VOUT
GND
7
NC
GND
8
NC
GND
An ISO 9001:2008 and DSCC Certified Company
23
TID Report
11-654 111206 R1.1
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Figure B.1. Irradiation bias circuit. This figure was extracted from Linear Technology RH1021-10 Datasheet.
Figure B.2. H package drawing (for reference only). This figure was extracted from Linear Technology RH102110 Datasheet.
Absolute Maximum Ratings:
Parameter
Max Rating
Input Voltage
40V
Input/Output Voltage Differential
35V
Output to Ground Voltage (Shunt Mode) 16V
Trim Pin to Ground Voltage Positive
VOUT
Trim Pin to Ground Voltage Negative
-20V
Output Short-Circuit Duration VIN=35V 10sec
Output Short-Circuit Duration VIN≤20V Indefinite
An ISO 9001:2008 and DSCC Certified Company
24
TID Report
11-654 111206 R1.1
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Appendix C: Electrical Test Parameters and Conditions
The expected ranges of values as well as the measurement conditions are taken from Linear Technology
RH1021-10 datasheet. All electrical tests for this device are performed on one of Aeroflex RAD's
LTS2020 Test Systems. The LTS2020 Test System is a programmable parametric tester that provides
parameter measurements for a variety of digital, analog and mixed signal products including voltage
regulators, voltage comparators, D to A and A to D converters. The LTS2020 Test System achieves
accuracy and sensitivity through the use of software self-calibration and an internal relay matrix with
separate family boards and custom personality adapter boards. The tester uses this relay matrix to
connect the required test circuits, select the appropriate voltage / current sources and establish the
needed measurement loops for all the tests performed. The measured parameters and test conditions are
shown in Table C.1.
A listing of the measurement precision/resolution for each parameter is shown in Table C.2. The
precision/resolution values were obtained from test data or from the DAC resolution of the LTS-2020
for the particular test shown, whichever is greater. To generate the precision/resolution shown in Table
C.2, one of the units-under-test was tested repetitively (a total of 10-times with re-insertion between
tests) to obtain the average test value and standard deviation. Using this test data MIL-HDBK-814 90/90
KTL statistics were applied to the measured standard deviation to generate the final measurement range.
This value encompasses the precision/resolution of all aspects of the test system, including the LTS2020
mainframe, family board, socket assembly and DUT board as well as insertion error. In some cases, the
measurement resolution is limited by the internal DACs, which results in a measured standard deviation
of zero. In these instances the precision/resolution will be reported back as the LSB of the DAC.
Note that the testing and statistics used in this document are based on an “analysis of variables”
technique, which relies on small sample sizes to qualify much larger lot sizes (see MIL-HDBK-814, p.
91 for a discussion of statistical treatments). Not all measured parameters are well suited to this
approach due to inherent large variations. If necessary, larger samples sizes could be used to qualify
these parameters using an “attributes” approach.
An ISO 9001:2008 and DSCC Certified Company
25
TID Report
11-654 111206 R1.1
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Table C.1. Measured parameters and test conditions for the RH1021CMH-10 Precision 10V Reference.
Parameter
Symbol
Test Conditions
Supply Current (A)
IS
VIN=15V, IOUT=0
Output Voltage (V)
VOUT
VIN=15V, IOUT=0
Line Regulation (ppm/V)
LINE REG1
11.5V ≤ VIN ≤ 14.5V
Line Regulation (ppm/V)
LINE REG2
14.5V < VIN ≤ 40V
Sourcing Load Regulation (ppm/mA) LOAD REG Source 0 ≤ IOUT ≤ 10mA
Sinking Load Regulation (ppm/mA)
LOAD REG Sink
1.7 ≤ IOUT ≤ 10mA
Minimum Current (Shunt Mode) (A)
IMIN
VIN is Open
Table C.2. Measured parameters, pre-irradiation specifications and measurement precision for the RH1021CMH10 Precision 10V Reference.
Pre-Irradiation Specification
Parameter
MIN
MAX
Supply Current (A)
Measurement Precision/Resolution
1.70E-03
±1.03E-05
Output Voltage (V)
9.995E+00
1.0005E+00
±8.71E-05
Line Regulation (ppm/V)
-4.00E+00
4.00E+00
±1.09E+00
Line Regulation (ppm/V)
-2.00E+00
2.00E+00
±1.14E-01
Sourcing Load Regulation (ppm/mA)
-2.50E+01
2.50E+01
±5.08E-01
Sinking Load Regulation (ppm/mA)
-1.00E+02
1.00E+02
±1.23E+00
1.50E-03
±7.49E-06
Minimum Current (Shunt Mode) (A)
An ISO 9001:2008 and DSCC Certified Company
26
TID Report
11-654 111206 R1.1
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Appendix D: List of Figures Used in the Results Section (Section 5)
5.1.
5.2.
5.3.
5.4.
5.5.
5.6.
5.7.
Supply Current (A) @ VIN=15V, IOUT=0
Output Voltage (V) @ VIN=15V, IOUT=0
Line Regulation (ppm/V) @ 11.5V ≤ VIN ≤ 14.5V
Line Regulation (ppm/V) @ 14.5V < VIN ≤ 40V
Sourcing Load Regulation (ppm/mA) @ 0 ≤ IOUT ≤ 10mA
Sinking Load Regulation (ppm/mA) @ 1.7 ≤ IOUT ≤ 10mA
Minimum Current (Shunt Mode) (A) @ VIN is Open