RECOM REC6

●
●
●
●
●
●
●
●
●
●
Features
Regulated
Converters
8kVDC & 10kVDC Reinforced Isolation
Industry Standard DIP24 Package
6W Regulated Output
Continuous Short Circuit Protection
Wide Input 2:1
Medical Approved
EN, CSA and CB Certificates
2 Pinout Options
Control Pin Option
Efficiency to 86%
ECONOLINE
DC/DC-Converter
6 Watt DIP24
Reinforced
Single & Dual
Output
Description
The REC6 series uses a reinforced isolation transformer to offer exceptionally high isolation of 8kVDC (4kVAC/1 minute)
or 10kVDC (5kVAC/1minute) making it suitable for HT monitoring circuits, mains power meters, IGBT isolated power
supplies and other sophisticated industrial and medical applications. The isolation capacitance of only 20pF makes them
also suitable for low leakage applications. The isolation transformer is recognised by CSA as reinforced isolated with a
minimum internal clearance of 2.4mm and a minimum internal creepage clearance o f4.6mm. The REC6 is available in
two industry-standard pinouts (= "/A" or "/C"). Remote on/off control is possible with the /CTRL option (A pinning only)
and an optional undervoltage lockout function is also available (="/X1"). The converters can deliver 140% rated power
for short periods of time to cope with applications with large capacitive loads or high start up currents.
Selection Guide
Input
Voltage
(VDC)
Output
Voltage
(VDC)
Output Efficiency Max. Cap.
Current
Load
(mA)
(%)
REC6-xx05SRW/R*
9 - 18, 18 - 36, 36 - 75
5
1000
80, 81, 82
REC6-xx09SRW/R*
9 - 18, 18 - 36, 36 - 75
9
667
81, 82, 83
555
80
500
82, 83, 84
417
82
400
84, 85, 86
333
83
250
83, 84, 85
208
82
±500
80, 81, 82
4.5 - 9
77
4.5 - 9
REC6-xx12SRW/R*
9 - 18, 18 - 36, 36 - 75
12
4.5 - 9
REC6-xx15SRW/R*
9 - 18, 18 - 36, 36 - 75
15
4.5 - 9
REC6-xx24SRW/R*
9 - 18, 18 - 36, 36 - 75
24
4.5 - 9
REC6-xx05DRW/R*
9 - 18, 18 - 36, 36 - 75
±5
4.5 - 9
REC6-xx09DRW/R*
9 - 18, 18 - 36, 36 - 75
9 - 18, 18 - 36, 36 - 75
±9
±12
4.5 - 9
REC6-xx15DRW/R*
9 - 18, 18 - 36, 36 - 75
4.5 - 9
RoHS
220µF
REC6/R
220µF
±470µF
±15
±335
81, 82, 83
±278
80
±250
81, 82, 83
±208
82
±200
82, 83, 84
±167
80
±220µF
±100µF
±100µF
* add suffix "/A" or "/C" for pinning options,
see next page for details.
* add suffix “/CTRL” for control pin option (A Pinning only)
* add suffix "/X1" for Undervoltage Lockout
* add suffix -R for Tape and Reel packaging
Ordering Examples:
REC6-0512DRW/R8/A/CTRL= 5V Vin, ±12V Vout, 8kVDC isolation, pinout “A”,control pin
REC6-4805SRW/R10/A = 48V Vin, 5V Vout, 10kVDC isolation, pinout “A”
REC6-1212DRW/R8/C/X1 = 12V Vin, ±12V Vout, 8kVDC isolation, pinout “C”,UVL
REC6-0505SRW/R10/A/CTRL/X1 = 5V Vin, 5V Vout, 10kVDC isolation, pinout “A”,control pin, UVL
www.recom-international.com
C22.2-No. 60950 Certified
C22.2-601.1 Certified
UL Certification Pending
470µF
R* = R8 or R10 for 8kVDC or 10kVDC isolation.
2:1 Input
(REC6-S_DRW/R8(R10)
xx = 4.5-9Vin = 05
xx = 9-18Vin = 12
xx = 18-36Vin = 24
xx = 36-75Vin = 48
2002/95/EC
6/6
470µF
77
4.5 - 9
REC6-xx12DRW/R*
1000µF
REV:0/2010
Derating-Graph
(Ambient Temperature)
Output Power (%)
Part
Number
DIP24
120
100
80
Safe Operating Area
60
40
20
0
-40
0
25
50 75
85
Operating Temperature (°C)
105 125
Refer to Application Notes
E-111
REC6-S_DRW
/R* Series
ECONOLINE
DC/DC-Converter
Specifications (measured at TA = 25°C, nominal input voltage, full load and after warm-up)
Input Voltage Range
2:1
Output Voltage Accuracy
±2% max.
Line Regulation
(HL-LL)
Load Regulation
Input Surge
(for output load current change from 20% to 100%)
(1 minute)
5V types
12V types
24V types
48V types
(/X1 Versions)
5V types
12V types
24V types
48V types
Undervoltage Lockout
Output Ripple and Noise
±0.3% max.
±0.6% max.
16V max.
25V max.
50V max.
100V max.
3.5V typ. (±20%)
7V typ. (±20%)
15V typ. (±10%)
32V typ. (±10%)
(0,1µF capacitor on output, 20MHz BW limited)
Transient Response
(25% step change)
Switching Frequency
(Full load and nominal input voltage)
200mVp-p max.
1ms typ.
100kHz min. / 350kHz max.
Input Filter
Pi Network
Capacitors
All types
Minimum Load
(Operation under no load will not damage the converter, but it may not meet all specifications)
No Load Power Consumption
Isolation Voltage
R8 types
Rated Working Voltage
Isolation Voltage
R10 types
Rated Working Voltage
MLCC capacitors only
400mW max.
8000VDC min.
4000VAC min.
see Application Notes
10000VDC min.
5000VAC min.
see Application Notes
(tested for 1 second)
(rated for 1 minute)
(long term isolation)
(tested for 1 second)
(rated for 1 minute)
(long term isolation)
Isolation Capacitance
20pF typ.
REC6/R
Isolation Resistance
10 GΩ min.
Short Circuit Protection
(Max operating temp. = 50°C during short circuit conditions)
Operating Temperature Range
(free air convection)
Continuous, Auto Restart
-40°C to +75°C (see Graph)
Case Temperature
105°C max.
Storage Temperature Range
-55°C to +125°C
Relative Humidity
95% RH
Case Material
Non-Conductive Plastic
Potting Material
Thermal Impedance
Silicone
20°C/W
Natural convection
Package Weight
Packing Quantity
14g
15 pcs per Tube
100 pcs per Reel
}
MTBF (+25°C)
Detailed Information see
(+75°C)
Application Notes chapter "MTBF"
EMC
Conducted Emissions
(with 470µF//0.1µF capacitors across input) Radiated Emissions
Reinforced Isolation
Transformer Creepage
Transformer Clearance
PCB Creepage & Clearance
Optocoupler Creepage
External Creepage and Clearance
Plastic Case
Certifications
CB Report
Medical Safety
CSA
Medical Safety
General Safety
using MIL-HDBK 217F
using MIL-HDBK 217F
EN55022
EN55022
/R8 and /R10 Types
/R8 and /R10 Types
/R8 and /R10 Types
/R8 and /R10 Types
Input <> Output pins
Ref: CA/11158/CSA
Report: 2202478
Report: 2219431
Recognised as Reinforced Isolation
E-112
10% Full Load
REV: 0/2010
953 x103 hours
234 x103 hours
Class A
Class A
4.6 mm min.
2.4 mm min.
6.0 mm min.
6.0 mm min.
14.2 mm min.
IEC60601-1:1988 + A1: 1991 + A2:1995
C22.2 601-1 2nd Ed.
UL 60601-1 1st Ed.
C22.2 No. 60950-1-03
UL 60950-1 1st Ed.
Supplement to Report: 2219431
www.recom-electronic.com
REC6-S_DRW
/R* Series
ECONOLINE
DC/DC-Converter
Typical Characteristics
Efficiency vs Vin
Efficiency vs Load
Efficiency VS Input Voltage
Efficiency / Load
100
1205
4805
80
60
2405
40
Efficiency (%)
Efficiency %
REC6-xx05SRW/R*
REC6-xx05DRW/R*
0505
20
0
0%
40%
20%
60%
Total Output current (%)
80%
100%
80
4812
1212,
2412
20
0
0%
40%
20%
60%
Total Output current (%)
80%
100%
4824
40
Efficiency (%)
Efficiency %
0524
1224,
2424
60
20
0
0%
40%
20%
60%
Total Output current (%)
www.recom-international.com
nom
max
max+20%
90
88
86
84
82
80
78
76
74
72
70
min
max
max+20%
4812
2412
1212
0512
nom
Efficiency VS Input Voltage
80
REC6-xx24SRW/R*
REC6-xx12DRW/R*
0505
Input Voltage (V)
Efficiency / Load
100
1205
80%
100%
90
88
86
84
82
80
78
76
74
72
70
min
1224
4824
2424
0524
nom
max
max+20%
Input Voltage (V)
REV:0/2010
E-113
REC6/R
Efficiency %
40
Efficiency (%)
REC6-xx12SRW/R*
2405
Efficiency VS Input Voltage
0512
60
4805
Input Voltage (V)
Efficiency / Load
100
90
88
86
84
82
80
78
76
74
72
70
min
REC6-S_DRW
/R* Series
ECONOLINE
DC/DC-Converter
Package Style and Pinning (mm) DIP 24 (continued)
3rd angle
projection
“A” Pinning
20.30
32.00
/R8 & /R10
Pin Connections
10.20
Pin #
4.1
15.24
0.51
4.60
Recommended Footprint Details
1.00 ø+0.15/–0
(1) 2
Single
Dual
CTRL
CTRL
1 (option)
11
2
–Vin
–Vin
11
NC
–Vout
14
+Vout
+Vout
16
–Vout
Com
22
+Vin
+Vin
23
+Vin
+Vin
NC = No Connection
Bottom View
23 22
16
2.54
14
2.54
CRTL Version only
XX.X ± 0.5 mm
XX.XX ± 0.25 mm
Top View
Vin+
CTRL Option
0V
ON = Open or 0V< Vctrl <1.2V
OFF = 2.2V< Vctrl <12V
2
REC6-xxxx/CTRL
CTRL
1
1kW
1N4148
Off
On
REC6/R
TTL Input
22,23
“C” Pinning
20.30
32.00
/R8 & /R10
Pin Connections
10.20
4.1
0.51
2.03
15.24
Recommended Footprint Details
1.00 ø+0.15/–0
1 2
10 11 12
15
2.54
13
2.54
E-114
Single
Dual
1
+Vin
+Vin
2
+Vin
+Vin
10
NC
Com
11
NC
Com
12
–Vout
NC
13
+Vout
–Vout
15
NC
+Vout
23
–Vin
–Vin
24
–Vin
–Vin
NC = No Connection
Bottom View
23 22
Pin #
XX.X ± 0.5 mm
XX.XX ± 0.25 mm
Top View
REV: 0/2010
www.recom-electronic.com