TI SN74F109N

SN54F109, SN74F109
DUAL J-K POSITIVE-EDGE-TRIGGERED FLIP-FLOPS
WITH CLEAR AND PRESET
SDFS047A – MARCH 1987 – REVISED OCTOBER 1993
SN54F109 . . . J PACKAGE
SN74F109 . . . D OR N PACKAGE
(TOP VIEW)
Package Options Include Plastic
Small-Outline Packages, Ceramic Chip
Carriers, and Standard Plastic and Ceramic
300-mil DIPs
1CLR
1J
1K
1CLK
1PRE
1Q
1Q
GND
description
These devices contain two independent J-K
positive-edge-triggered flip-flops. A low level at
the preset (PRE) or clear (CLR) inputs sets or
resets the outputs regardless of the levels of the
other inputs. When PRE and CLR are inactive
(high), data at the J and K input meeting the
setup-time requirements are transferred to the
outputs on the positive-going edge of the clock
pulse. Clock triggering occurs at a voltage level
and is not directly related to the rise time of the
clock pulse. Following the hold time interval, data
at the J and K inputs may be changed without
affecting the levels at the outputs. These versatile
flip-flops can perform as toggle flip-flops by
grounding K and trying J high. They also can
perform as D-type flip-flops if J and K are tied
together.
1
16
2
15
3
14
4
13
5
12
6
11
7
10
8
9
VCC
2CLR
2J
2K
2CLK
2PRE
2Q
2Q
1J
1CLR
NC
SN54F109 . . . FK PACKAGE
(TOP VIEW)
1K
1CLK
NC
1PRE
1Q
4
3 2 1 20 19
18
5
17
6
16
7
15
8
14
9 10 11 12 13
2J
2K
NC
2CLK
2PRE
1Q
GND
NC
2Q
2Q
The SN54F109 is characterized for operation over
the full military temperature range of – 55°C to
125°C. The SN74F109 is characterized for
operation from 0°C to 70°C.
VCC
2CLR
•
NC – No internal connection
FUNCTION TABLE
INPUTS
OUTPUTS
PRE
CLR
CLK
J
K
Q
L
H
X
X
X
H
Q
L
H
L
X
X
X
H
H†
H
L
L
X
X
X
L
H†
H
H
↑
L
L
L
H
H
↑
H
L
H
H
↑
L
H
Q0
Q0
H
H
↑
H
H
H
L
Toggle
H
H
L
X
X
Q0
Q0
† The output levels are not guaranteed to meet the minimum
levels for VOH. Furthermore, this configuration is nonstable;
that is, it will not persist when PRE or CLR returns to its
inactive (high) level.
Copyright  1993, Texas Instruments Incorporated
PRODUCTION DATA information is current as of publication date.
Products conform to specifications per the terms of Texas Instruments
standard warranty. Production processing does not necessarily include
testing of all parameters.
POST OFFICE BOX 655303
• DALLAS, TEXAS 75265
2–1
SN54F109, SN74F109
DUAL J-K POSITIVE-EDGE-TRIGGERED FLIP-FLOPS
WITH CLEAR AND PRESET
SDFS047A – MARCH 1987 – REVISED OCTOBER 1993
logic symbol†
1PRE
1J
1CLK
5
S
2
4
2J
2CLK
2K
2CLR
7
1K
1K
2PRE
1Q
C1
3
1CLR
6
1J
1
1Q
R
11
14
10
2Q
12
9
13
2Q
15
† This symbol is in accordance with ANSI/IEEE Std 91-1984 and IEC Publication 617-12.
Pin numbers shown are for the D, J, and N packages.
absolute maximum ratings over operating free-air temperature range (unless otherwise noted)‡
Supply voltage range, VCC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . – 0.5 V to 7 V
Input voltage range, VI (see Note 1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . – 1.2 V to 7 V
Input current range . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . – 30 mA to 5 mA
Voltage range applied to any output in the high state . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . – 0.5 V to VCC
Current into any output in the low state . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40 mA
Operating free-air temperature range: SN54F109 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . – 55°C to 125°C
SN74F109 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0°C to 70°C
Storage temperature range . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . – 65°C to 150°C
‡ Stresses beyond those listed under “absolute maximum ratings” may cause permanent damage to the device. These are stress ratings only and
functional operation of the device at these or any other conditions beyond those indicated under “recommended operating conditions” is not
implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
NOTE 1: The input voltage ratings may be exceeded provided the input current ratings are observed.
recommended operating conditions
SN54F109
VCC
VIH
Supply voltage
VIL
IIK
Low-level input voltage
IOH
IOL
TA
Operating free-air temperature
2–2
High-level input voltage
SN74F109
MIN
NOM
MAX
MIN
NOM
MAX
4.5
5
5.5
4.5
5
5.5
2
2
UNIT
V
V
0.8
0.8
V
– 18
– 18
mA
High-level output current
–1
–1
mA
Low-level output current
20
20
mA
70
°C
Input clamp current
– 55
POST OFFICE BOX 655303
• DALLAS, TEXAS 75265
125
0
SN54F109, SN74F109
DUAL J-K POSITIVE-EDGE-TRIGGERED FLIP-FLOPS
WITH CLEAR AND PRESET
SDFS047A – MARCH 1987 – REVISED OCTOBER 1993
electrical characteristics over recommended operating free-air temperature range (unless
otherwise noted)
PARAMETER
VIK
VOH
VOL
II
IIH
J, K, CLK
IIL
PRE or CLR
SN54F109
TYP†
MAX
TEST CONDITIONS
VCC = 4.5 V,
VCC = 4.5 V,
II = – 18 mA
IOH = – 1 mA
VCC = 4.75 V,
VCC = 4.5 V,
IOH = – 1 mA
IOL = 20 mA
VCC = 5.5 V,
VCC = 5.5 V,
VI = 7 V
VI = 2.7 V
VCC = 5
5.5
5V
V,
VI = 0
0.5
5V
MIN
SN74F109
TYP†
MAX
MIN
– 1.2
2.5
3.4
– 1.2
2.5
3.4
0.5
V
V
2.7
0.3
UNIT
0.5
V
0.1
0.3
0.1
mA
20
20
µA
– 0.6
– 0.6
– 1.8
– 1.8
IOS‡
VCC = 5.5 V,
VO = 0
– 60
–150
– 60
ICC
VCC = 5.5 V,
See Note 2
11.7
17
11.7
† All typical values are at VCC = 5 V, TA = 25°C.
‡ Not more than one output should be shorted at a time, and the duration of the short circuit should not exceed one second.
NOTE 2: ICC is measured with J, K, CLK, and PRE grounded then with J, K, CLK, and CLR grounded.
mA
–150
mA
17
mA
timing requirements over recommended ranges of supply voltage and operating free-air
temperature (unless otherwise noted)
VCC = 5 V,
TA = 25°C
SN54F109
SN74F109
UNIT
′F74
fclock
tw
tsu
Clock frequency
Pulse duration
Setup time,
time data before CLK↑
Setup time, inactive-state before CLK↑§
th
Hold time
time, data after CLK↑
MIN
MAX
MIN
MAX
MIN
MAX
0
100
0
70
0
90
CLK high, PRE or CLR low
4
4
4
CLK low
5
5
5
High
3
3
3
Low
3
3
3
PRE or CLR to CLK
2
2
2
High
1
1
1
Low
1
1
1
MHz
ns
ns
ns
§ Inactive-state setup time is also referred to as recovery time.
switching characteristics (see Note 3)
PARAMETER
FROM
(INPUT)
TO
(OUTPUT)
VCC = 5 V,
CL = 50 pF,
RL = 500 Ω,
TA = 25°C
VCC = 4.5 V to 5.5 V,
CL = 50 pF,
RL = 500 Ω,
TA = MIN to MAX¶
′F109
fmax
tPLH
MIN
TYP
100
150
MAX
UNIT
SN54F109
SN74F109
MIN
MIN
MAX
70
MAX
90
MHz
3
4.9
7
3
9
3
8
3.6
5.8
8
3.6
10.5
3.6
9.2
2.4
4.8
7
2.4
9
2.4
8
tPHL
2.7
6.6
9
2.7
11.5
2.7
¶ For conditions shown as MIN or MAX, use the appropriate value specified under recommended operating conditions.
NOTE 3: Load circuits and waveforms are shown in Section 1.
10.5
tPHL
tPLH
CLK
Q or Q
PRE or CLR
Q or Q
POST OFFICE BOX 655303
• DALLAS, TEXAS 75265
ns
ns
2–3
SN54F109, SN74F109
DUAL J-K POSITIVE-EDGE-TRIGGERED FLIP-FLOPS
WITH CLEAR AND PRESET
SDFS047A – MARCH 1987 – REVISED OCTOBER 1993
2–4
POST OFFICE BOX 655303
• DALLAS, TEXAS 75265
PACKAGE OPTION ADDENDUM
www.ti.com
28-Feb-2005
PACKAGING INFORMATION
Orderable Device
Status (1)
Package
Type
Package
Drawing
Pins Package Eco Plan (2)
Qty
Lead/Ball Finish
MSL Peak Temp (3)
5962-9758001Q2A
ACTIVE
LCCC
FK
20
1
None
Call TI
Level-NC-NC-NC
5962-9758001QEA
ACTIVE
CDIP
J
16
1
None
Call TI
Level-NC-NC-NC
5962-9758001QFA
ACTIVE
CFP
W
16
1
None
Call TI
Level-NC-NC-NC
JM38510/34102B2A
ACTIVE
LCCC
FK
20
1
None
Call TI
Level-NC-NC-NC
JM38510/34102BEA
ACTIVE
CDIP
J
16
1
None
Call TI
Level-NC-NC-NC
JM38510/34102BFA
ACTIVE
CFP
W
16
1
None
Call TI
Level-NC-NC-NC
SN74F109D
ACTIVE
SOIC
D
16
40
Pb-Free
(RoHS)
CU NIPDAU
Level-2-260C-1 YEAR/
Level-1-235C-UNLIM
SN74F109DR
ACTIVE
SOIC
D
16
2500
Pb-Free
(RoHS)
CU NIPDAU
Level-2-260C-1 YEAR/
Level-1-235C-UNLIM
SN74F109N
ACTIVE
PDIP
N
16
25
Pb-Free
(RoHS)
CU NIPDAU
Level-NC-NC-NC
SNJ54F109FK
ACTIVE
LCCC
FK
20
1
None
Call TI
Level-NC-NC-NC
SNJ54F109J
ACTIVE
CDIP
J
16
1
None
Call TI
Level-NC-NC-NC
SNJ54F109W
ACTIVE
CFP
W
16
1
None
Call TI
Level-NC-NC-NC
(1)
The marketing status values are defined as follows:
ACTIVE: Product device recommended for new designs.
LIFEBUY: TI has announced that the device will be discontinued, and a lifetime-buy period is in effect.
NRND: Not recommended for new designs. Device is in production to support existing customers, but TI does not recommend using this part in
a new design.
PREVIEW: Device has been announced but is not in production. Samples may or may not be available.
OBSOLETE: TI has discontinued the production of the device.
(2)
Eco Plan - May not be currently available - please check http://www.ti.com/productcontent for the latest availability information and additional
product content details.
None: Not yet available Lead (Pb-Free).
Pb-Free (RoHS): TI's terms "Lead-Free" or "Pb-Free" mean semiconductor products that are compatible with the current RoHS requirements
for all 6 substances, including the requirement that lead not exceed 0.1% by weight in homogeneous materials. Where designed to be soldered
at high temperatures, TI Pb-Free products are suitable for use in specified lead-free processes.
Green (RoHS & no Sb/Br): TI defines "Green" to mean "Pb-Free" and in addition, uses package materials that do not contain halogens,
including bromine (Br) or antimony (Sb) above 0.1% of total product weight.
(3)
MSL, Peak Temp. -- The Moisture Sensitivity Level rating according to the JEDECindustry standard classifications, and peak solder
temperature.
Important Information and Disclaimer:The information provided on this page represents TI's knowledge and belief as of the date that it is
provided. TI bases its knowledge and belief on information provided by third parties, and makes no representation or warranty as to the
accuracy of such information. Efforts are underway to better integrate information from third parties. TI has taken and continues to take
reasonable steps to provide representative and accurate information but may not have conducted destructive testing or chemical analysis on
incoming materials and chemicals. TI and TI suppliers consider certain information to be proprietary, and thus CAS numbers and other limited
information may not be available for release.
In no event shall TI's liability arising out of such information exceed the total purchase price of the TI part(s) at issue in this document sold by TI
to Customer on an annual basis.
Addendum-Page 1
IMPORTANT NOTICE
Texas Instruments Incorporated and its subsidiaries (TI) reserve the right to make corrections, modifications,
enhancements, improvements, and other changes to its products and services at any time and to discontinue
any product or service without notice. Customers should obtain the latest relevant information before placing
orders and should verify that such information is current and complete. All products are sold subject to TI’s terms
and conditions of sale supplied at the time of order acknowledgment.
TI warrants performance of its hardware products to the specifications applicable at the time of sale in
accordance with TI’s standard warranty. Testing and other quality control techniques are used to the extent TI
deems necessary to support this warranty. Except where mandated by government requirements, testing of all
parameters of each product is not necessarily performed.
TI assumes no liability for applications assistance or customer product design. Customers are responsible for
their products and applications using TI components. To minimize the risks associated with customer products
and applications, customers should provide adequate design and operating safeguards.
TI does not warrant or represent that any license, either express or implied, is granted under any TI patent right,
copyright, mask work right, or other TI intellectual property right relating to any combination, machine, or process
in which TI products or services are used. Information published by TI regarding third-party products or services
does not constitute a license from TI to use such products or services or a warranty or endorsement thereof.
Use of such information may require a license from a third party under the patents or other intellectual property
of the third party, or a license from TI under the patents or other intellectual property of TI.
Reproduction of information in TI data books or data sheets is permissible only if reproduction is without
alteration and is accompanied by all associated warranties, conditions, limitations, and notices. Reproduction
of this information with alteration is an unfair and deceptive business practice. TI is not responsible or liable for
such altered documentation.
Resale of TI products or services with statements different from or beyond the parameters stated by TI for that
product or service voids all express and any implied warranties for the associated TI product or service and
is an unfair and deceptive business practice. TI is not responsible or liable for any such statements.
Following are URLs where you can obtain information on other Texas Instruments products and application
solutions:
Products
Applications
Amplifiers
amplifier.ti.com
Audio
www.ti.com/audio
Data Converters
dataconverter.ti.com
Automotive
www.ti.com/automotive
DSP
dsp.ti.com
Broadband
www.ti.com/broadband
Interface
interface.ti.com
Digital Control
www.ti.com/digitalcontrol
Logic
logic.ti.com
Military
www.ti.com/military
Power Mgmt
power.ti.com
Optical Networking
www.ti.com/opticalnetwork
Microcontrollers
microcontroller.ti.com
Security
www.ti.com/security
Telephony
www.ti.com/telephony
Video & Imaging
www.ti.com/video
Wireless
www.ti.com/wireless
Mailing Address:
Texas Instruments
Post Office Box 655303 Dallas, Texas 75265
Copyright  2005, Texas Instruments Incorporated