EXAR XR16L2750IJ

áç
XR16L2750
2.25V TO 5.5V DUART WITH 64-BYTE FIFO
SEPTEMBER 2002
REV. 1.0.0
GENERAL DESCRIPTION
The XR16L27501 (2750) is a low voltage dual
universal asynchronous receiver and transmitter
(UART) with 5 Volt tolerant inputs. The device
operates from 2.25 to 5.5 Volt supply range and is
pin-to-pin compatible to Exar’s ST16C2550 and
XR16C2850 except the 48-TQFP package. The 2750
register set is compatible to the ST16C2550 and the
XR16C2850 enhanced features. It supports the
Exar’s enhanced features of 64 bytes of TX and RX
FIFOs, programmable FIFO trigger level and FIFO
level counters, automatic hardware (RTS/CTS) and
software flow control, automatic RS-485 half duplex
direction control output and a complete modem
interface. Onboard registers provide the user with
operational status and data error flags. An internal
loopback capability allows system diagnostics.
Independent programmable baud rate generators are
provided in each channel to select data rates up to
6.25 Mbps at 5 Volt and 8X sampling clock. The 2750
is available in 48-pin TQFP and 44-pin PLCC
packages.
FEATURES
• 2.25 to 5.5 Volt Operation
• 5 Volt Tolerant Inputs
• Pin-to-pin compatible to Exar’s ST16C2550 and
TI’s TL16C752B on the 48-TQFP package
• Pin alike XR16C2850 48-TQFP package but
without CLK8/16, CLKSEL and HDCNTL inputs
• Two independent UART channels
■
■
■
■
■
■
■
■
■
■
NOTE: 1 Covered by U.S. Patent #5,649,122 and #5,832,205
■
APPLICATIONS
• Portable Appliances
• Telecommunication Network Routers
• Ethernet Network Routers
• Cellular Data Devices
• Factory Automation and Process Controls
■
Reg set compatible to 16C2550 and 16C2850
Up to 6.25 Mbps at 5 Volt, 4 Mbps at 3.3 Volt,
and 3 Mbps at 2.5 Volt with 8X sampling rate
Transmit and Receive FIFOs of 64 bytes
Programmable TX and RX FIFO Trigger Levels
Transmit and Receive FIFO Level Counters
Automatic Hardware (RTS/CTS) Flow Control
Selectable Auto RTS Flow Control Hysteresis
Automatic Software (Xon/Xoff) Flow Control
Automatic RS-485 Half-duplex Direction
Control Output via RTS#
Wireless Infrared (IrDA 1.0) Encoder/Decoder
Automatic sleep mode
Full modem interface
• Device Identification and Revision
• Crystal oscillator or external clock input
• Industrial and commercial temperature ranges
• 48-TQFP and 44-PLCC packages
FIGURE 1. XR16L2750 BLOCK DIAGRAM
* 5 Volt Tolerant Inputs
A2:A0
GND
D7:D0
IOR#
UART Channel A
IOW#
UART
Regs
CSA#
CSB#
INTA
INTB
TXRDYA#
TXRDYB#
RXRDYA#
RXRDYB#
Reset
2.25 to 5.5 Volt VCC
8-bit Data
Bus
Interface
64 Byte TX FIFO
TX & RX
IR
ENDEC
TXA, RXA, DTRA#,
DSRA#, RTSA#,
DTSA#, CDA#, RIA#,
OP2A#
BRG
UART Channel B
(same as Channel A)
Crystal Osc/Buffer
TXB, RXB, DTRB#,
DSRB#, RTSB#,
CTSB#, CDB#, RIB#,
OP2B#
XTAL1
XTAL2
2750BLK
Exar Corporation 48720 Kato Road, Fremont CA, 94538 • (510) 668-7000 • FAX (510) 668-7017 • www.exar.com
áç
XR16L2750
2.25V TO 5.5V DUART WITH 64-BYTE FIFO
REV. 1.0.0
CDA#
DSRA#
CTSA#
NC
38
37
RIA#
41
39
VCC
42
40
D0
TXRDYA#
43
D1
45
44
D3
D2
46
D4
48
47
FIGURE 2. PIN OUT ASSIGNMENT
RESET
D5
1
36
D6
2
35
DTRB#
D7
3
34
DTRA#
RXB
4
33
RTSA#
RXA
5
32
OP2A#
31
RXRDYA#
TXRDYB#
XR16L2750
48-pin TQFP
6
DSRA#
CTSA#
41
40
23
CDA#
42
24
RIA#
43
NC
VCC
CTSB#
TXRDYA#
1
D0
2
44
D1
3
CDB#
D2
4
IOW#
D3
5
XTAL1
XTAL2
D4
6
22
NC
RTSB#
25
21
A2
NC 12
RIB#
26
19
A1
CSB# 11
20
27
IOR#
A0
CSA# 10
DSRB#
28
18
9
RXRDYB#
INTB
OP2B#
16
29
17
8
GND
INTA
TXB
15
30
14
7
13
TXA
D5
7
39
RESET
D6
8
38
DTRB#
D7
9
37
DTRA#
RXB
10
36
RTSA#
RXA
11
35 OP2A#
TXRDYB#
12
34
RXRDYA#
TXA
13
33
INTA
TXB
14
32
INTB
OP2B#
15
31
A0
CSA#
16
30 A1
CSB#
17
29
A2
CTSB# 28
RIB# 26
RTSB# 27
DSRB# 25
IOR# 24
RXRDYB# 23
GND 22
IOW# 20
CDB# 21
XTAL2 19
XTAL1 18
XR16L2750
44-pin PLCC
ORDERING INFORMATION
PART NUMBER
PACKAGE
OPERATING TEMPERATURE RANGE
XR16L2750CJ
44-PLCC
0°C to +70°C
XR16L2750IJ
44-PLCC
-40°C to +85°C
XR16L2750CM
48-TQFP
0°C to +70°C
XR16L2750IM
48-TQFP
-40°C to +85°C
2
áç
XR16L2750
2.25V TO 5.5V DUART WITH 64-BYTE FIFO
REV. 1.0.0
PIN DESCRIPTIONS
Pin Description
NAME
44-PLCC
PIN #
48-TQFP
PIN #
TYPE
DESCRIPTION
Address data lines [2:0]. These 3 address lines select one of the internal registers in UART channel A/B during a data bus transaction.
DATA BUS INTERFACE
A2:A0
29, 30, 31
26, 27, 28
I
D7:D0
9, 8, 7, 6, 5,
4, 3, 2
3, 2, 1, 48,
47, 46, 45,
44
I/O
IOR#
24
19
I
Input/Output Read Strobe (active low). The falling edge instigates an
internal read cycle and retrieves the data byte from an internal register
pointed to by the address lines [A2:A0]. The data byte is placed on the
data bus to allow the host processor to read it on the rising edge.
IOW#
20
15
I
Input/Output Write Strobe (active low). The falling edge instigates an
internal write cycle and the rising edge transfers the data byte on the
data bus to an internal register pointed by the address lines.
CSA#
16
10
I
UART channel A select (active low) to enable UART channel A in the
device for data bus operation.
CSB#
17
11
I
UART channel B select (active low) to enable UART channel B in the
device for data bus operation.
INTA
33
30
O
UART channel A Interrupt output. The output state is defined by the
user through the software setting of MCR[3]. INTA is set to the active
mode and OP2A# output to a logic 0 when MCR[3] is set to a logic 1.
INTA is set to the three state mode and OP2A# to a logic 1 when
MCR[3] is set to a logic 0 (default). See MCR[3].
INTB
32
29
O
UART channel B Interrupt output. The output state is defined by the
user through the software setting of MCR[3]. INTB is set to the active
mode and OP2B# output to a logic 0 when MCR[3] is set to a logic 1.
INTB is set to the three state mode and OP2B# to a logic 1 when
MCR[3] is set to a logic 0 (default). See MCR[3].
TXRDYA#
1
43
O
UART channel A Transmitter Ready (active low). The output
provides the TX FIFO/THR status for transmit channel A. See
Table 2. If it is not used, leave it unconnected.
RXRDYA#
34
31
O
UART channel A Receiver Ready (active low). This output provides the
RX FIFO/RHR status for receive channel A. See Table 2. If it is not
used, leave it unconnected.
TXRDYB#
12
6
O
UART channel B Transmitter Ready (active low). The output provides
the TX FIFO/THR status for transmit channel B. See Table 2. If it is not
used, leave it unconnected.
RXRDYB#
23
18
O
UART channel B Receiver Ready (active low). This output provides the
RX FIFO/RHR status for receive channel B. See Table 2. If it is not
used, leave it unconnected.
Data bus lines [7:0] (bidirectional).
3
áç
XR16L2750
2.25V TO 5.5V DUART WITH 64-BYTE FIFO
REV. 1.0.0
Pin Description
NAME
44-PLCC
PIN #
48-TQFP
PIN #
TYPE
DESCRIPTION
MODEM OR SERIAL I/O INTERFACE
TXA
13
7
O
UART channel A Transmit Data or infrared encoder data. Standard
transmit and receive interface is enabled when MCR[6] = 0. In this
mode, the TX signal will be a logic 1 during reset or idle (no data). Infrared IrDA transmit and receive interface is enabled when MCR[6] = 1. In
the Infrared mode, the inactive state (no data) for the Infrared encoder/
decoder interface is a logic 0. If it is not used, leave it unconnected.
RXA
11
5
I
UART channel A Receive Data or infrared receive data. Normal receive
data input must idle at logic 1 condition. The infrared receiver pulses
typically idles at logic 0 but can be inverted by software control prior
going in to the decoder, see MCR[6] and FCTR[2]. If this pin is not
used, tie it to VCC or pull it high via a 100k ohm resistor.
RTSA#
36
33
O
UART channel A Request-to-Send (active low) or general purpose output. This output must be asserted prior to using auto RTS flow control,
see EFR[6], MCR[1], FCTR[1:0], EMSR[5:4] and IER[6]. For auto
RS485 half-duplex direction control, see FCTR[3] and EMSR[3].
CTSA#
40
38
I
UART channel A Clear-to-Send (active low) or general purpose input.
It can be used for auto CTS flow control, see EFR[7], and IER[7]. This
input should be connected to VCC when not used.
DTRA#
37
34
O
UART channel A Data-Terminal-Ready (active low) or general purpose
output. If it is not used, leave it unconnected.
DSRA#
41
39
I
UART channel A Data-Set-Ready (active low) or general purpose input.
This input should be connected to VCC when not used. This input has
no effect on the UART.
CDA#
42
40
I
UART channel A Carrier-Detect (active low) or general purpose input.
This input should be connected to VCC when not used. This input has
no effect on the UART.
RIA#
43
41
I
UART channel A Ring-Indicator (active low) or general purpose input.
This input should be connected to VCC when not used. This input has
no effect on the UART.
OP2A#
35
32
O
Output Port 2 Channel A - The output state is defined by the user and
through the software setting of MCR[3]. INTA is set to the active mode
and OP2A# output to a logic 0 when MCR[3] is set to a logic 1. INTA is
set to the three state mode and OP2A# to a logic 1 when MCR[3] is set
to a logic 0. See MCR[3]. This output should not be used as a general
output else it will disturb the INTA output functionality.
TXB
14
8
O
UART channel B Transmit Data or infrared encoder data. Standard
transmit and receive interface is enabled when MCR[6] = 0. In this
mode, the TX signal will be a logic 1 during reset or idle (no data). Infrared IrDA transmit and receive interface is enabled when MCR[6] = 1. In
the Infrared mode, the inactive state (no data) for the Infrared encoder/
decoder interface is a logic 0. If it is not used, leave it unconnected.
4
áç
XR16L2750
2.25V TO 5.5V DUART WITH 64-BYTE FIFO
REV. 1.0.0
Pin Description
NAME
44-PLCC
PIN #
48-TQFP
PIN #
TYPE
DESCRIPTION
RXB
10
4
I
UART channel B Receive Data or infrared receive data. Normal receive
data input must idle at logic 1 condition. The infrared receiver pulses
typically idles at logic 0 but can be inverted by software control prior
going in to the decoder, see MCR[6] and FCTR[2]. If this pin is not
used, tie it to VCC or pull it high via a 100k ohm resistor.
RTSB#
27
22
O
UART channel B Request-to-Send (active low) or general purpose output. This port must be asserted prior to using auto RTS flow control,
see EFR[6], MCR[1], FCTR[1:0], EMSR[5:4] and IER[6]. For auto
RS485 half-duplex direction control, see FCTR[3] and EMSR[3].
CTSB#
28
23
I
UART channel B Clear-to-Send (active low) or general purpose input.
It can be used for auto CTS flow control, see EFR[7], and IER[7]. This
input should be connected to VCC when not used.
DTRB#
38
35
O
UART channel B Data-Terminal-Ready (active low) or general purpose
output. If it is not used, leave it unconnected.
DSRB#
25
20
I
UART channel B Data-Set-Ready (active low) or general purpose input.
This input should be connected to VCC when not used. This input has
no effect on the UART.
CDB#
21
16
I
UART channel B Carrier-Detect (active low) or general purpose input.
This input should be connected to VCC when not used. This input has
no effect on the UART.
RIB#
26
21
I
UART channel B Ring-Indicator (active low) or general purpose input.
This input should be connected to VCC when not used. This input has
no effect on the UART.
OP2B#
15
9
O
Output Port 2 Channel B - The output state is defined by the user and
through the software setting of MCR[3]. INTB is set to the active mode
and OP2B# output to a logic 0 when MCR[3] is set to a logic 1. INTB is
set to the three state mode and OP2B# to a logic 1 when MCR[3] is set
to a logic 0. See MCR[3]. This output should not be used as a general
output else it will disturb the INTB output functionality.
ANCILLARY SIGNALS
XTAL1
18
13
I
Crystal or external clock input. Caution: this input is not 5V tolerant.
XTAL2
19
14
O
Crystal or buffered clock output.
RESET
39
36
I
Reset (active high) - A longer than 40 ns logic 1 pulse on this pin will
reset the internal registers and all outputs. The UART transmitter output
will be held at logic 1, the receiver input will be ignored and outputs are
reset during reset period (see External Reset Conditions).
VCC
44
42
Pwr
2.25V to 5.5V power supply. All input pins, except XTAL1, are 5V tolerant.
GND
22
17
Pwr
Power supply common, ground.
N.C.
none
12, 24, 25,
37
No Connection. These pins are open, but typically, should be connected to GND for good design practice.
Pin type: I=Input, O=Output, I/O= Input/output, OD=Output Open Drain.
5
áç
XR16L2750
2.25V TO 5.5V DUART WITH 64-BYTE FIFO
REV. 1.0.0
1.0 PRODUCT DESCRIPTION
The XR16L2750 (2750) integrates the functions of 2 enhanced 16C550 Universal Asynchronous Receiver and
Transmitter (UART). Each UART is independently controlled having its own set of device configuration
registers. The configuration registers set is 16550 UART compatible for control, status and data transfer.
Additionally, each UART channel has 64-bytes of transmit and receive FIFOs, automatic RTS/CTS hardware
flow control with hysteresis control, automatic Xon/Xoff and special character software flow control,
programmable transmit and receive FIFO trigger levels, FIFO level counters, infrared encoder and decoder
(IrDA ver 1.0), programmable baud rate generator with a prescaler of divide by 1 or 4, and data rate up to 6.25
Mbps with 8X sampling clock rate or 3.125 Mbps in the 16X rate. The XR16L2750 is a 2.25 to 5.5V device with
5 volt tolerant inputs. The 2750 is fabricated with an advanced CMOS process.
Enhanced Features
The 2750 DUART provides a solution that supports 64 bytes of transmit and receive FIFO memory, instead of
128 bytes provided in the XR16C2850 and 16 bytes in the ST16C2550, or one byte in the ST16C2450. The
2750 is designed to work with low supply voltage and high performance data communication systems, that
require fast data processing time. Increased performance is realized in the 2750 by the larger transmit and
receive FIFOs, FIFO trigger level control, FIFO level counters and automatic flow control mechanism. This
allows the external processor to handle more networking tasks within a given time. For example, the
ST16C2550 with a 16 byte FIFO, unloads 16 bytes of receive data in 1.53 ms (This example uses a character
length of 11 bits, including start/stop bits at 115.2 Kbps). This means the external CPU will have to service the
receive FIFO at 1.53 ms intervals. However with the 64 byte FIFO in the 2750, the data buffer will not require
unloading/loading for 6.1 ms. This increases the service interval giving the external CPU additional time for
other applications and reducing the overall UART interrupt servicing time. In addition, the programmable FIFO
level trigger interrupt and automatic hardware/software flow control is uniquely provided for maximum data
throughput performance especially when operating in a multi-channel system. The combination of the above
greatly reduces the CPU’s bandwidth requirement, increases performance, and reduces power consumption.
The 2750 supports a half-duplex output direction control signaling pin, RTS# A/B, to enable and disable the
external RS-485 transceiver operation. It automatically switches the logic state of the output pin to the receive
state after the last stop-bit of the last character has been shifted out of the transmitter. After receiving, the logic
state of the output pin switches back to the transmit state when a data byte is loaded in the transmitter. The
auto RS-485 direction control pin is not activated after reset. To activate the direction control function, user has
to set FCTR Bit-3 to “1”. This pin is normally high for receive state, low for transmit state.
Data Rate
The 2750 is capable of operation up to 3.125 Mbps at 5V with 16X internal sampling clock rate, and 6.25 Mbps
at 5V with 8X sampling clock rate. The device can operate with an external 24 MHz crystal on pins XTAL1 and
XTAL2, or external clock source of up to 50 MHz on XTAL1 pin. With a typical crystal of 14.7456 MHz and
through a software option, the user can set the prescaler bit for data rates of up to 1.84 Mbps.
The rich feature set of the 2750 is available through the internal registers. Automatic hardware/software flow
control, selectable transmit and receive FIFO trigger levels, selectable TX and RX baud rates, infrared encoder/
decoder interface, modem interface controls, and a sleep mode are all standard features.
Following a power on reset or an external reset, the 2750 is software compatible with previous generation of
UARTs, 16C450, 16C550 and 16C650A as well as the 16C850.
6
áç
XR16L2750
2.25V TO 5.5V DUART WITH 64-BYTE FIFO
REV. 1.0.0
2.0 FUNCTIONAL DESCRIPTIONS
2.1
CPU Interface
The CPU interface is 8 data bits wide with 3 address lines and control signals to execute data bus read and
write transactions. The 2750 data interface supports the Intel compatible types of CPUs and it is compatible to
the industry standard 16C550 UART. No clock (oscillator nor external clock) is required to operate a data bus
transaction. Each bus cycle is asynchronous using CS#, IOR# and IOW# signals. Both UART channels share
the same data bus for host operations. The data bus interconnections are shown in Figure 3.
FIGURE 3. XR16L2750 DATA BUS INTERCONNECTIONS
D0
D1
D2
D3
D4
D5
D6
D7
D0
D1
D2
D3
D4
D5
D6
D7
A0
A1
A2
A0
A1
VCC
UART
Channel A
IOR#
IOR#
IOW#
UART_CSA#
UART_CSB#
CSA#
CSB#
UART_INTA
INTA
UART_INTB
INTB
TXRDYA#
TXRDYA#
RXRDYA#
RXRDYA#
TXRDYB#
TXRDYB#
RXRDYB#
DTRA#
RTSA#
CTSA#
DSRA#
Serial Interface of
RS-232, RS-485
CDA#
RIA#
OP2A#
A2
IOW#
VCC
TXA
RXA
TXB
RXB
UART
Channel B
DTRB#
RTSB#
CTSB#
DSRB#
CDB#
Serial Interface of
RS-232, RS-485
RIB#
OP2B#
RXRDYB#
UART_RESET
RESET
GND
2750int
2.2
5-Volt Tolerant Inputs
The 2750 can accept up to 5V inputs even when operating at 3.3V or 2.5V. But note that if the 2750 is operating
at 2.5V, its VOH may not be high enough to meet the requirements of the VIH of a CPU or a serial transceiver
that is operating at 5V. Caution: XTAL1 is not 5 volt tolerant.
2.3
Device Reset
The RESET input resets the internal registers and the serial interface outputs in both channels to their default
state (see Table 16). An active high pulse of longer than 40 ns duration will be required to activate the reset
function in the device.
2.4
Device Identification and Revision
The XR16L2750 provides a Device Identification code and a Device Revision code to distinguish the part from
other devices and revisions. To read the identification code from the part, it is required to set the baud rate
generator registers DLL and DLM both to 0x00. Now reading the content of the DLM will provide 0x0A for the
XR16L2750 and reading the content of DLL will provide the revision of the part; for example, a reading of 0x01
means revision A.
2.5
Channel A and B Selection
The UART provides the user with the capability to bi-directionally transfer information between an external CPU
and an external serial communication device. A logic 0 on chip select pins, CSA# or CSB#, allows the user to
select UART channel A or B to configure, send transmit data and/or unload receive data to/from the UART.
7
áç
XR16L2750
2.25V TO 5.5V DUART WITH 64-BYTE FIFO
REV. 1.0.0
Selecting both UARTs can be useful during power up initialization to write to the same internal registers, but do
not attempt to read from both uarts simultaneously. Individual channel select functions are shown in Table 1.
TABLE 1: CHANNEL A AND B SELECT
2.6
CSA#
CSB#
FUNCTION
1
1
UART de-selected
0
1
Channel A selected
1
0
Channel B selected
0
0
Channel A and B selected
Channel A and B Internal Registers
Each UART channel in the 2750 has a set of enhanced registers for control, monitoring and data loading and
unloading. The configuration register set is compatible to those already available in the standard single 16C550
and dual ST16C2550. These registers function as data holding registers (THR/RHR), interrupt status and
control registers (ISR/IER), a FIFO control register (FCR), receive line status and control registers (LSR/LCR),
modem status and control registers (MSR/MCR), programmable data rate (clock) divisor registers (DLL/DLM),
and a user accessible Scratchpad Register (SPR).
Beyond the general 16C2550 features and capabilities, the 2750 offers enhanced feature registers (EMSR,
FLVL, EFR, Xon/Xoff 1, Xon/Xoff 2, FCTR, TRG, FC) that provide automatic RTS and CTS hardware flow
control, Xon/Xoff software flow control, automatic RS-485 half-duplex direction output enable/disable, FIFO
trigger level control, and FIFO level counters. All the register functions are discussed in full detail later in
“Section 3.0, UART INTERNAL REGISTERS” on page 19.
2.7
DMA Mode
The device does not support direct memory access. The DMA Mode (a legacy term) in this document doesn’t
mean “direct memory access” but refers to data block transfer operation. The DMA mode affects the state of
the RXRDY# A/B and TXRDY# A/B output pins. The transmit and receive FIFO trigger levels provide additional
flexibility to the user for block mode operation. The LSR bits 5-6 provide an indication when the transmitter is
empty or has an empty location(s) for more data. The user can optionally operate the transmit and receive
FIFO in the DMA mode (FCR bit-3=1). When the transmit and receive FIFO are enabled and the DMA mode is
disabled (FCR bit-3 = 0), the 2750 is placed in single-character mode for data transmit or receive operation.
When DMA mode is enabled (FCR bit-3 = 1), the user takes advantage of block mode operation by loading or
unloading the FIFO in a block sequence determined by the programmed trigger level. In this mode, the 2750
sets the TXRDY# pin when the transmit FIFO becomes full, and sets the RXRDY# pin when the receive FIFO
becomes empty. The following table shows their behavior. Also see Figures 18 through 23.
TABLE 2: TXRDY# AND RXRDY# OUTPUTS IN FIFO AND DMA MODE
PINS
FCR BIT-0=0
(FIFO DISABLED)
FCR BIT-0=1 (FIFO ENABLED)
FCR Bit-3 = 0
(DMA Mode Disabled)
FCR Bit-3 = 1
(DMA Mode Enabled)
RXRDY# A/B 0 = 1 byte.
1 = no data.
0 = at least 1 byte in FIFO
1 = FIFO empty.
1 to 0 transition when FIFO reaches the trigger
level, or time-out occurs.
0 to 1 transition when FIFO empties.
TXRDY# A/B 0 = THR empty.
1 = byte in THR.
0 = FIFO empty.
1 = at least 1 byte in FIFO.
0 = FIFO has at least 1 empty location.
1 = FIFO is full.
8
áç
XR16L2750
2.25V TO 5.5V DUART WITH 64-BYTE FIFO
REV. 1.0.0
2.8
INTA and INTB Outputs
The INTA and INTB interrupt output changes according to the operating mode and enhanced features setup.
Table 3 and 4 summarize the operating behavior for the transmitter and receiver. Also see Figures 18
through 23.
TABLE 3: INTA AND INTB PINS OPERATION FOR TRANSMITTER
Auto RS485
Mode
FCR BIT-0 = 1
(FIFO ENABLED)
FCR BIT-0 = 0
(FIFO DISABLED)
INTA/B Pin
NO
0 = a byte in THR
1 = THR empty
0 = FIFO above trigger level
1 = FIFO below trigger level or FIFO empty
INTA/B Pin
YES
0 = a byte in THR
1 = transmitter empty
0 = FIFO above trigger level
1 = FIFO below trigger level or transmitter empty
TABLE 4: INTA AND INTB PIN OPERATION FOR RECEIVER
FCR BIT-0 = 0
(FIFO DISABLED)
INTA/B Pin
2.9
0 = no data
1 = 1 byte
FCR BIT-0 = 1
(FIFO ENABLED)
0 = FIFO below trigger level
1 = FIFO above trigger level
Crystal Oscillator or External Clock Input
The 2750 includes an on-chip oscillator (XTAL1 and XTAL2) to produce a clock for both UART sections in the
device. The CPU data bus does not require this clock for bus operation. The crystal oscillator provides a
system clock to the Baud Rate Generators (BRG) section found in each of the UART. XTAL1 is the input to the
oscillator or external clock buffer input with XTAL2 pin being the output. Please note that the input XTAL1 is not
5V tolerant and so the maximum at the pin should be VCC. For programming details, see “Programmable Baud
Rate Generator.”
FIGURE 4. TYPICAL OSCILLATOR CONNECTIONS
XTAL1
XTAL2
R2
500 ΚΩ − 1 ΜΩ
Y1
C1
22-47 pF
C2
22-47 pF
9
R1
0-120 Ω
(Optional)
1.8432 MHz
to
24 MHz
áç
XR16L2750
2.25V TO 5.5V DUART WITH 64-BYTE FIFO
REV. 1.0.0
The on-chip oscillator is designed to use an industry standard microprocessor crystal (parallel resonant,
fundamental frequency with 10-22 pF capacitance load, ESR of 20-120 ohms and 100 ppm frequency
tolerance) connected externally between the XTAL1 and XTAL2 pins (see Figure 4). The programmable Baud
Rate Generator is capable of operating with a crystal oscillator frequency of up to 24 MHz. However, with an
external clock input on XTAL1 pin and a 2K ohms pull-up resistor on XTAL2 pin (as shown in Figure 5) it can
extend its operation up to 50 MHz (6.25 Mbps serial data rate) at 5V with an 8X sampling rate.
FIGURE 5. EXTERNAL CLOCK CONNECTION FOR EXTENDED DATA RATE
External Clock
vcc
XTAL1
gnd
VCC
R1
2K
XTAL2
For further reading on the oscillator circuit please see the Application Note DAN108 on the EXAR web site at
http://www.exar.com.
2.10
Programmable Baud Rate Generator
Each UART has its own Baud Rate Generator (BRG) with a prescaler. The prescaler is controlled by a software
bit in the MCR register. The MCR register bit-7 sets the prescaler to divide the input crystal or external clock by
1 or 4. The clock output of the prescaler goes to the BRG. The BRG further divides this clock by a
programmable divisor between 1 and (216 -1) to obtain a 16X sampling rate clock of the serial data rate. The
sampling rate clock is used by the transmitter for data bit shifting and receiver for data sampling. The BRG
divisor defaults to the maximum baud rate (DLL = 0x01 and DLM = 0x00) upon power up.
FIGURE 6. BAUD RATE GENERATOR AND PRESCALER
D L L an d D L M
R e g iste rs
P re s ca le r
D iv id e b y 1
X T A L1
X T A L2
C ry s ta l
O sc/
B u ffer
M C R B it-7 = 0
(d e fa ult)
B a u d R a te
G e n era to r
L o g ic
P re s ca le r
D iv id e b y 4
16X
S a m plin g
R a te C lo c k to
T ra n sm itte r
M C R B it-7 = 1
Programming the Baud Rate Generator Registers DLM and DLL provides the capability of selecting the
operating data rate. Table 5 shows the standard data rates available with a 14.7456 MHz crystal or external
clock at 16X sampling rate clock rate. A 16X sampling clock is typically used. However, user can select the 8X
10
áç
XR16L2750
2.25V TO 5.5V DUART WITH 64-BYTE FIFO
REV. 1.0.0
sampling clock rate mode (EMSR bit-7=0) to double the operating data rate. When using a non-standard data
rate crystal or external clock, the divisor value can be calculated for DLL/DLM with the following equation.
divisor (decimal) = (XTAL1 clock frequency / prescaler) / (serial data rate x 16), with 16XMode [EMSR bit-7] = 1
divisor (decimal) = (XTAL1 clock frequency / prescaler) / (serial data rate x 8), with 16XMode [EMSR bit-7] = 0
TABLE 5: TYPICAL DATA RATES WITH A 14.7456 MHZ CRYSTAL OR EXTERNAL CLOCK
OUTPUT Data Rate OUTPUT Data Rate
DIVISOR FOR 16x DIVISOR FOR 16x
MCR Bit-7=1
MCR Bit-7=0
Clock (Decimal) Clock (HEX)
(DEFAULT)
DLM
PROGRAM
VALUE (HEX)
DLL
PROGRAM
VALUE (HEX)
DATA RATE
ERROR (%)
100
400
2304
900
09
00
0
600
2400
384
180
01
80
0
1200
4800
192
C0
00
C0
0
2400
9600
96
60
00
60
0
4800
19.2k
48
30
00
30
0
9600
38.4k
24
18
00
18
0
19.2k
76.8k
12
0C
00
0C
0
38.4k
153.6k
6
06
00
06
0
57.6k
230.4k
4
04
00
04
0
115.2k
460.8k
2
02
00
02
0
230.4k
921.6k
1
01
00
01
0
2.11
Transmitter
The transmitter section comprises of an 8-bit Transmit Shift Register (TSR) and 64 bytes of FIFO which
includes a byte-wide Transmit Holding Register (THR). TSR shifts out every data bit with the 16X/8X internal
clock. A bit time is 16 (8) clock periods (see EMSR bit-7). The transmitter sends the start-bit followed by the
number of data bits, inserts the proper parity-bit if enabled, and adds the stop-bit(s). The status of the FIFO
and TSR are reported in the Line Status Register (LSR bit-5 and bit-6).
2.11.1
Transmit Holding Register (THR) - Write Only
The transmit holding register is an 8-bit register providing a data interface to the host processor. The host
writes transmit data byte to the THR to be converted into a serial data stream including start-bit, data bits,
parity-bit and stop-bit(s). The least-significant-bit (Bit-0) becomes first data bit to go out. The THR is the input
register to the transmit FIFO of 64 bytes when FIFO operation is enabled by FCR bit-0. Every time a write
operation is made to the THR, the FIFO data pointer is automatically bumped to the next sequential data
location.
2.11.2
Transmitter Operation in non-FIFO Mode
The host loads transmit data to THR one character at a time. The THR empty flag (LSR bit-5) is set when the
data byte is transferred to TSR. THR flag can generate a transmit empty interrupt (ISR bit-1) when it is enabled
by IER bit-1. The TSR flag (LSR bit-6) is set when TSR becomes completely empty.
11
áç
XR16L2750
2.25V TO 5.5V DUART WITH 64-BYTE FIFO
REV. 1.0.0
FIGURE 7. TRANSMITTER OPERATION IN NON-FIFO MODE
Transmit
Holding
Register
(THR)
Data
Byte
16X or 8X
Clock
(EMSR Bit-7)
THR Interrupt (ISR bit-1)
Enabled by IER bit-1
Transmit Shift Register (TSR)
M
S
B
L
S
B
TXNOFIFO1
2.11.3
Transmitter Operation in FIFO Mode
The host may fill the transmit FIFO with up to 64 bytes of transmit data. The THR empty flag (LSR bit-5) is set
whenever the FIFO is empty. The THR empty flag can generate a transmit empty interrupt (ISR bit-1) when the
amount of data in the FIFO falls below its programmed trigger level. The transmit empty interrupt is enabled by
IER bit-1. The TSR flag (LSR bit-6) is set when TSR/FIFO becomes empty.
FIGURE 8. TRANSMITTER OPERATION IN FIFO AND FLOW CONTROL MODE
Transmit
Data Byte
Transmit
FIFO
THR Interrupt (ISR bit-1) falls
below the programmed Trigger
Level and then when becom es
empty. FIFO is Enabled by FCR
bit-0=1
Auto CTS Flow Control (CTS# pin)
Flow Control Characters
(Xoff1/2 and Xon1/2 Reg.
Auto Software Flow Control
16X or 8X Clock
(EMSR bit-7)
Transmit Data Shift Register
(TSR)
T XF IF O 1
2.12
Receiver
The receiver section contains an 8-bit Receive Shift Register (RSR) and 64 bytes of FIFO which includes a
byte-wide Receive Holding Register (RHR). The RSR uses the 16X/8X clock (EMSR bit-7) for timing. It verifies
and validates every bit on the incoming character in the middle of each data bit. On the falling edge of a start or
false start bit, an internal receiver counter starts counting at the 16X/8X clock rate. After 8 clocks (or 4 if 8X) the
start bit period should be at the center of the start bit. At this time the start bit is sampled and if it is still a logic
0 it is validated. Evaluating the start bit in this manner prevents the receiver from assembling a false character.
The rest of the data bits and stop bits are sampled and validated in this same manner to prevent false framing.
If there were any error(s), they are reported in the LSR register bits 2-4. Upon unloading the receive data byte
from RHR, the receive FIFO pointer is bumped and the error tags are immediately updated to reflect the status
of the data byte in RHR register. RHR can generate a receive data ready interrupt upon receiving a character
or delay until it reaches the FIFO trigger level. Furthermore, data delivery to the host is guaranteed by a receive
12
áç
XR16L2750
2.25V TO 5.5V DUART WITH 64-BYTE FIFO
REV. 1.0.0
data ready time-out interrupt when data is not received for 4 word lengths as defined by LCR[1,0] plus 12 bits
time. This is equivalent to 3.7-4.6 character times. The RHR interrupt is enabled by IER bit-0.
2.12.1
Receive Holding Register (RHR) - Read-Only
The Receive Holding Register is an 8-bit register that holds a receive data byte from the Receive Shift Register.
It provides the receive data interface to the host processor. The RHR register is part of the receive FIFO of 64
bytes by 11-bits wide, the 3 extra bits are for the 3 error tags to be reported in LSR register. When the FIFO is
enabled by FCR bit-0, the RHR contains the first data character received by the FIFO. After the RHR is read,
the next character byte is loaded into the RHR and the errors associated with the current data byte are
immediately updated in the LSR bits 2-4.
FIGURE 9. RECEIVER OPERATION IN NON-FIFO MODE
16 X or 8X C lo ck
(E M S R bit-7)
R ece ive D a ta S h ift
R egiste r (R S R )
E rror
T ags in
LS R bits
4:2
R ece ive
D ata B yte
an d E rro rs
D ata B it
V a lid ation
R ece ive D a ta
H old ing R e giste r
(R H R )
R e ce ive D a ta C h a ra cte rs
R H R In terrup t (IS R b it-2 )
R X F IF O 1
FIGURE 10. RECEIVER OPERATION IN FIFO AND AUTO RTS FLOW CONTROL MODE
16X or 8X Clock
(EMSR bit-7)
Receive Data Shift
Register (RSR)
Data Bit
Validation
Error Tags
(64-sets)
64 bytes by 11-bit
wide
FIFO
Receive
Data FIFO
Enable by EFR bit-6=1, MCR bit-1.
FIFO
Trigger=16
Error Tags in
LSR bits 4:2
Data fills to
24
Receive Data
Byte and Errors
Receive Data Characters
Example
- :RX FIFO trigger level selected at 16
bytes
(See Note Below)
Data falls to
RTS# re-asserts when data falls below the flow
8
control trigger level to restart remote transmitter.
RHR Interrupt (ISR bit-2) programmed for
desired FIFO trigger level.
FIFO is Enabled by FCR bit-0=1
RTS# de-asserts when data fills above the flow
control trigger level to suspend remote transmitter.
Enable by EFR bit-6=1, MCR bit-1.
Receive
Data
RXFIFO1
NOTE: Table-B selected as Trigger Table for Figure 10 (Table 10).
13
áç
XR16L2750
2.25V TO 5.5V DUART WITH 64-BYTE FIFO
REV. 1.0.0
2.13
Auto RTS (Hardware) Flow Control
Automatic RTS hardware flow control is used to prevent data overrun to the local receiver FIFO. The RTS#
output is used to request remote unit to suspend/resume data transmission. The auto RTS flow control features
is enabled to fit specific application requirement (see Figure 11):
- Enable auto RTS flow control using EFR bit-6.
- The auto RTS function must be started by asserting RTS# output pin (MCR bit-1 to logic 1 after it is enabled).
- Enable RTS interrupt through IER bit-6 (after setting EFR bit-4). The UART issues an interrupt when the
RTS# pin makes a transition from low to high: ISR bit-5 will be set to logic 1.
2.14
Auto RTS Hysteresis
The 2750 has a new feature that provides flow control trigger hysteresis while maintaining compatibility with the
XR16C850, ST16C650A and ST16C550 family of UARTs. With the Auto RTS function enabled, an interrupt is
generated when the receive FIFO reaches the programmed RX trigger level. The RTS# pin will not be forced to
a logic 1 (RTS off), until the receive FIFO reaches the upper limit of the hysteresis level. The RTS# pin will
return to a logic 0 after the RX FIFO is unloaded to the lower limit of the hysteresis level. Under the above
described conditions, the 2750 will continue to accept data until the receive FIFO gets full. The Auto RTS
function is initiated when the RTS# output pin is asserted to a logic 0 (RTS On). Table 13 shows the complete
details for the Auto RTS# Hysteresis levels. Please note that this table is for programmable trigger levels only
(Table D). The hysteresis values for Tables A-C are the next higher and next lower trigger levels in the
corresponding table.
2.15
Auto CTS Flow Control
Automatic CTS flow control is used to prevent data overrun to the remote receiver FIFO. The CTS# input is
monitored to suspend/restart the local transmitter. The auto CTS flow control feature is selected to fit specific
application requirement (see Figure 11):
- Enable auto CTS flow control using EFR bit-7.
- Enable CTS interrupt through IER bit-7 (after setting EFR bit-4). The UART issues an interrupt when the
CTS# pin is de-asserted (logic 1): ISR bit-5 will be set to 1, and UART will suspend transmission as soon as the
stop bit of the character in process is shifted out. Transmission is resumed after the CTS# input is re-asserted
(logic 0), indicating more data may be sent.
14
áç
XR16L2750
2.25V TO 5.5V DUART WITH 64-BYTE FIFO
REV. 1.0.0
FIGURE 11. AUTO RTS AND CTS FLOW CONTROL OPERATION
Local UART
UARTA
Remote UART
UARTB
Receiver FIFO
Trigger Reached
Auto RTS
Trigger Level
TXB
RTSA#
CTSB#
Auto CTS
Monitor
RXB
Receiver FIFO
Trigger Reached
TXA
Transmitter
CTSA#
Auto CTS
Monitor
RTSA#
RXA
RTSB#
Assert RTS# to Begin
Transmission
1
ON
Auto RTS
Trigger Level
10
OFF
ON
7
2
ON
CTSB#
Transmitter
3
8
OFF
6
Suspend
11
ON
TXB
Data Starts
Restart
9
4
RXA FIFO
INTA
(RXA FIFO
Interrupt)
Receive
Data
RX FIFO
Trigger Level
5
RTS High
Threshold
RTS Low
Threshold
12
RX FIFO
Trigger Level
RTSCTS1
The local UART (UARTA) starts data transfer by asserting RTSA# (1). RTSA# is normally connected to CTSB# (2) of
remote UART (UARTB). CTSB# allows its transmitter to send data (3). TXB data arrives and fills UARTA receive FIFO
(4). When RXA data fills up to its receive FIFO trigger level, UARTA activates its RXA data ready interrupt (5) and continues to receive and put data into its FIFO. If interrupt service latency is long and data is not being unloaded, UARTA
monitors its receive data fill level to match the upper threshold of RTS delay and de-assert RTSA# (6). CTSB# follows
(7) and request UARTB transmitter to suspend data transfer. UARTB stops or finishes sending the data bits in its transmit shift register (8). When receive FIFO data in UARTA is unloaded to match the lower threshold of RTS delay (9),
UARTA re-asserts RTSA# (10), CTSB# recognizes the change (11) and restarts its transmitter and data flow again until
next receive FIFO trigger (12). This same event applies to the reverse direction when UARTA sends data to UARTB
with RTSB# and CTSA# controlling the data flow.
15
áç
XR16L2750
2.25V TO 5.5V DUART WITH 64-BYTE FIFO
REV. 1.0.0
2.16
Auto Xon/Xoff (Software) Flow Control
When software flow control is enabled (See Table 15), the 2750 compares one or two sequential receive data
characters with the programmed Xon or Xoff-1,2 character value(s). If receive character(s) (RX) match the
programmed values, the 2750 will halt transmission (TX) as soon as the current character has completed
transmission. When a match occurs, the Xoff (if enabled via IER bit-5) flag will be set and the interrupt output
pin will be activated. Following a suspension due to a match of the Xoff character, the 2750 will monitor the
receive data stream for a match to the Xon-1,2 character. If a match is found, the 2750 will resume operation
and clear the flags (ISR bit-4).
Reset initially sets the contents of the Xon/Xoff 8-bit flow control registers to a logic 0. Following reset the user
can write any Xon/Xoff value desired for software flow control. Different conditions can be set to detect Xon/
Xoff characters (See Table 15) and suspend/resume transmissions. When double 8-bit Xon/Xoff characters are
selected, the 2750 compares two consecutive receive characters with two software flow control 8-bit values
(Xon1, Xon2, Xoff1, Xoff2) and controls TX transmissions accordingly. Under the above described flow control
mechanisms, flow control characters are not placed (stacked) in the user accessible RX data buffer or FIFO.
In the event that the receive buffer is overfilling and flow control needs to be executed, the 2750 automatically
sends an Xoff message (when enabled) via the serial TX output to the remote modem. The 2750 sends the
Xoff-1,2 characters two-character-times (= time taken to send two characters at the programmed baud rate)
after the receive FIFO crosses the programmed trigger level (for all trigger tables A-D). To clear this condition,
the 2750 will transmit the programmed Xon-1,2 characters as soon as receive FIFO is less than one trigger
level below the programmed trigger level (for Trigger Tables A, B, and C) or when receive FIFO is less than the
trigger level minus the hysteresis value (for Trigger Table D). This hysteresis value is the same as the Auto RTS
Hysteresis value in Table 14. Table 6 below explains this when Trigger Table-B (See Table 10) is selected.
TABLE 6: AUTO XON/XOFF (SOFTWARE) FLOW CONTROL
RX TRIGGER LEVEL
INT PIN ACTIVATION
XOFF CHARACTER(S) SENT
(CHARACTERS IN RX FIFO)
XON CHARACTER(S) SENT
(CHARACTERS IN RX FIFO)
8
8
8*
0
16
16
16*
8
24
24
24*
16
28
28
28*
24
* After the trigger level is reached, an xoff character is sent after a short span of time (= time required to send 2
characters); for example, after 2.083ms has elapsed for 9600 baud and 10-bit word length setting.
2.17
Special Character Detect
A special character detect feature is provided to detect an 8-bit character when bit-5 is set in the Enhanced
Feature Register (EFR). When this character (Xoff2) is detected, it will be placed in the FIFO along with normal
incoming RX data.
The 2750 compares each incoming receive character with Xoff-2 data. If a match exists, the received data will
be transferred to FIFO and ISR bit-4 will be set to indicate detection of special character. Although the Internal
Register Table shows Xon, Xoff Registers with eight bits of character information, the actual number of bits is
dependent on the programmed word length. Line Control Register (LCR) bits 0-1 defines the number of
character bits, i.e., either 5 bits, 6 bits, 7 bits, or 8 bits. The word length selected by LCR bits 0-1 also
determines the number of bits that will be used for the special character comparison. Bit-0 in the Xon, Xoff
Registers corresponds with the LSB bit for the receive character.
2.18
Auto RS485 Half-duplex Control
The auto RS485 half-duplex direction control changes the behavior of the transmitter when enabled by FCTR
bit-3. By default, it de-asserts RTS# (logic 1) output following the last stop bit of the last character that has been
transmitted. This helps in turning around the transceiver to receive the remote station’s response. When the
host is ready to transmit next polling data packet again, it only has to load data bytes to the transmit FIFO. The
transmitter automatically re-asserts RTS# (logic 0) output prior to sending the data. The RS485 half-duplex
direction control output can be inverted by enabling EMSR bit-3.
16
áç
XR16L2750
2.25V TO 5.5V DUART WITH 64-BYTE FIFO
REV. 1.0.0
2.19
Infrared Mode
The 2750 UART includes the infrared encoder and decoder compatible to the IrDA (Infrared Data Association)
version 1.0. The IrDA 1.0 standard that stipulates the infrared encoder sends out a 3/16 of a bit wide HIGHpulse for each “0” bit in the transmit data stream. This signal encoding reduces the on-time of the infrared LED,
hence reduces the power consumption. See Figure 12 below.
The infrared encoder and decoder are enabled by setting MCR register bit-6 to a ‘1’. When the infrared feature
is enabled, the transmit data output, TX, idles at logic zero level. Likewise, the RX input assumes an idle level
of logic zero from a reset and power up, see Figure 12.
Typically, the wireless infrared decoder receives the input pulse from the infrared sensing diode on the RX pin.
Each time it senses a light pulse, it returns a logic 1 to the data bit stream. However, this is not true with some
infrared modules on the market which indicate a logic 0 by a light pulse. So the 2750 has a provision to invert
the input polarity to accommodate this. In this case user can enable FCTR bit-2 to invert the input signal.
FIGURE 12. INFRARED TRANSMIT DATA ENCODING AND RECEIVE DATA DECODING
T X D ata
0
Stop
Start
C haracter
D ata B its
1
0
1
0
1
0
1
1
0
T ransm it
IR P ulse
(T X P in)
1/2 B it T im e
B it T im e
3/16 B it T im e
IrE ncoder-1
Receive
IR Pulse
(RX pin)
Bit Time
1/16 Clock Delay
1
0
1
0
0
Data Bits
1
1
0
1
Stop
0
Start
RX Data
Character
IRdecoder-1
2.20
Sleep Mode with Auto Wake-Up
The 2750 supports low voltage system designs, hence, a sleep mode is included to reduce its power
consumption when the chip is not actively used. With EFR bit-4 and IER bit-4 of both channels enabled (set to
a logic 1), the 2750 DUART enters sleep mode when no interrupt is pending for both channels. The 2750 stops
its crystal oscillator to further conserve power in the sleep mode. User can check the XTAL2 pin for no clock
output as an indication that the device has entered the sleep mode. The 2750 resumes normal operation by
any of the following: a receive data start bit transition (logic 1 to 0), a change of logic state on any of the modem
or general purpose input pins: CTS#, DSR#, CD#, RI# or a transmit data byte is loaded to the THR/FIFO by the
user. If the 2750 is awakened by one of the above conditions, it will return to the sleep mode automatically after
all interrupting condition have been serviced and cleared. If the 2750 is awakened by the modem inputs, a read
to the MSR is required to reset the modem inputs. In any case, the sleep mode will not be entered while an
17
áç
XR16L2750
2.25V TO 5.5V DUART WITH 64-BYTE FIFO
REV. 1.0.0
interrupt is pending from channel A or B. The 2750 will stay in the sleep mode of operation until it is disabled by
setting IER bit-4 to a logic 0.
A word of caution: owing to the starting up delay of the crystal oscillator after waking up from sleep mode, the
first few receive characters may be lost. Also, make sure the RX A/B inputs are idling at logic 1 or “marking”
condition during sleep mode to avoid receiving a “break” condition upon the restart. This may occur when the
external interface transceivers (RS-232, RS-485 or another type) are also put to sleep mode and cannot
maintain the “marking” condition. To avoid this, the system design engineer can use a 47k ohm pull-up resistor
on the RXA and RXB pins.
2.21
Internal Loopback
The 2750 UART provides an internal loopback capability for system diagnostic purposes. The internal
loopback mode is enabled by setting MCR register bit-4 to logic 1. All regular UART functions operate normally.
Figure 13 shows how the modem port signals are re-configured. Transmit data from the transmit shift register
output is internally routed to the receive shift register input allowing the system to receive the same data that it
was sending. The TX pin is held at logic 1 or mark condition while RTS# and DTR# are de-asserted, and
CTS#, DSR# CD# and RI# inputs are ignored. Caution: the RX input must be held to a logic 1 during loopback
test else upon exiting the loopback test the UART may detect and report a false “break” signal. Also, Auto RTS/
CTS is not supported during internal loopback.
FIGURE 13. INTERNAL LOOP BACK IN CHANNEL A AND B
VCC
TXA/TXB
Transmit Shift Register
(THR/FIFO)
Receive Shift Register
(RHR/FIFO)
RXA/RXB
VCC
RTSA#/RTSB#
RTS#
Modem / General Purpose Control Logic
Internal Data Bus Lines and Control Signals
MCR bit-4=1
CTS#
CTSA#/CTSB#
VCC
DTRA#/DTRB#
DTR#
DSR#
DSRA#/DSRB#
OP1#
RI#
RIA#/RIB#
VCC
OP2A#/OP2B#
OP2#
CD#
CDA#/CDB#
18
áç
XR16L2750
2.25V TO 5.5V DUART WITH 64-BYTE FIFO
REV. 1.0.0
3.0 UART INTERNAL REGISTERS
Each of the UART channel in the 2750 has its own set of configuration registers selected by address lines A0,
A1 and A2 with CSA# or CSB# selecting the channel. The complete register set is shown on Table 7 and
Table 8.
TABLE 7: UART CHANNEL A AND B UART INTERNAL REGISTERS
A2,A1,A0 ADDRESSES
REGISTER
READ/WRITE
COMMENTS
16C550 COMPATIBLE REGISTERS
0
0 0
RHR - Receive Holding Register
THR - Transmit Holding Register
Read-only
Write-only
LCR[7] = 0
0
0 0
DLL - Div Latch Low Byte
Read/Write
LCR[7] = 1, LCR ≠ 0xBF
0
0 1
DLM - Div Latch High Byte
Read/Write
LCR[7] = 1, LCR ≠ 0xBF
0
0 0
DREV - Device Revision Code
Read-only
DLL, DLM = 0x00,
LCR[7] = 1, LCR ≠ 0xBF
0
0 1
DVID - Device Identification Code
Read-only
DLL, DLM = 0x00,
LCR[7] = 1, LCR ≠ 0xBF
0
0 1
IER - Interrupt Enable Register
Read/Write
LCR[7] = 0
0
1 0
ISR - Interrupt Status Register
FCR - FIFO Control Register
Read-only
Write-only
LCR[7] = 0
0
1 1
LCR - Line Control Register
Read/Write
1
0 0
MCR - Modem Control Register
Read/Write
LCR[7] = 0
1
0 1
LSR - Line Status Register
Reserved
Read-only
Write-only
LCR[7] = 0
1
1 0
MSR - Modem Status Register
Reserved
Read-only
Write-only
LCR[7] = 0
1
1 1
SPR - Scratch Pad Register
Read/Write
LCR[7] = 0, FCTR[6] = 0
1
1 1
FLVL - RX/TX FIFO Level Counter Register
Read-only
LCR[7] = 0, FCTR[6] = 1
1
1 1
EMSR - Enhanced Mode Select Register
Write-only
LCR[7] = 0, FCTR[6] = 1
ENHANCED REGISTERS
0
0 0
TRG - RX/TX FIFO Trigger Level Register
FC - RX/TX FIFO Level Counter Register
Write-only
Read-only
LCR = 0xBF
0
0 1
FCTR - Feature Control Register
Read/Write
LCR = 0xBF
0
1 0
EFR - Enhanced Function Register
Read/Write
LCR = 0xBF
1
0 0
Xon-1 - Xon Character 1
Read/Write
LCR = 0xBF
1
0 1
Xon-2 - Xon Character 2
Read/Write
LCR = 0xBF
1
1 0
Xoff-1 - Xoff Character 1
Read/Write
LCR = 0xBF
1
1 1
Xoff-2 - Xoff Character 2
Read/Write
LCR = 0xBF
19
áç
XR16L2750
2.25V TO 5.5V DUART WITH 64-BYTE FIFO
REV. 1.0.0
.
TABLE 8: INTERNAL REGISTERS DESCRIPTION. SHADED BITS ARE ENABLED WHEN EFR BIT-4=1
ADDRESS
A2-A0
REG
NAME
READ/
WRITE
BIT-7
BIT-6
BIT-5
BIT-4
BIT-3
BIT-2
BIT-1
BIT-0
COMMENT
16C550 Compatible Registers
000
RHR
RD
Bit-7
Bit-6
Bit-5
Bit-4
Bit-3
Bit-2
Bit-1
Bit-0
000
THR
WR
Bit-7
Bit-6
Bit-5
Bit-4
Bit-3
Bit-2
Bit-1
Bit-0
001
IER
RD/WR
0/
0/
0/
0/
CTS Int. RTS Int.
Enable Enable
Xoff Int.
Enable
Sleep
Mode
Enable
FIFOs
FIFOs
Enabled Enabled
0/
0/
INT
Source
Bit-5
INT
Source
Bit-4
0/
0/
010
010
ISR
FCR
RD
WR
RX FIFO RX FIFO
Trigger Trigger
TX FIFO TX FIFO
Trigger Trigger
011
LCR
RD/WR
Divisor
Enable
Set TX
Break
Set Parity
100
MCR
RD/WR
0/
0/
0/
BRG
Prescaler
Even
Parity
Modem RX Line
TX
RX
Stat. Int.
Stat.
Empty
Data
Int
Int.
Enable
Int.
Enable Enable Enable
INT
Source
Bit-3
INT
INT
INT
Source Source Source
Bit-2
Bit-1
Bit-0
DMA
Mode
Enable
TX
FIFO
Reset
RX
FIFO
Reset
Parity
Enable
Stop
Bits
Word
Word
Length Length
Bit-1
Bit-0
FIFOs
Enable
Internal OP2#/INT Rsrvd RTS# DTR#
Lopback Output (OP1#) Output Output
IR Mode XonAny Enable
Enable
Control Control
ENable
101
LSR
RD
RX FIFO
Global
Error
THR &
TSR
Empty
THR
Empty
RX
Break
RX Framing Error
RX
Parity
Error
RX
Overrun
Error
RX
Data
Ready
110
MSR
RD
CD#
Input
RI#
Input
DSR#
Input
CTS#
Input
Delta
CD#
Delta
RI#
Delta
DSR#
Delta
CTS#
111
SPR
RD/WR
Bit-7
Bit-6
Bit-5
Bit-4
Bit-3
Bit-2
Bit-1
Bit-0
111
EMSR
WR
16X
Sampling
Rate
Mode
LSR
Error
Interrupt.
Imd/Dly#
Auto
RTS
Hyst.
bit-3
Auto
RTS
Hyst.
bit-2
Auto
RS485
Output
Inversion
Rsrvd
Rx/Tx
FIFO
Count
Rx/Tx
FIFO
Count
Bit-7
Bit-6
Bit-5
Bit-4
Bit-3
Bit-2
111
FLVL
RD
LCR[7] = 0
20
LCR[7] = 0
LCR[7] = 0
FCTR[6]=0
LCR[7] = 0
FCTR[6]=1
Bit-1
Bit-0
áç
XR16L2750
2.25V TO 5.5V DUART WITH 64-BYTE FIFO
REV. 1.0.0
TABLE 8: INTERNAL REGISTERS DESCRIPTION. SHADED BITS ARE ENABLED WHEN EFR BIT-4=1
ADDRESS
A2-A0
REG
NAME
READ/
WRITE
BIT-7
BIT-6
BIT-5
BIT-4
BIT-3
BIT-2
BIT-1
BIT-0
COMMENT
LCR[7] = 1
LCR ≠ 0xBF
Baud Rate Generator Divisor
000
DLL
RD/WR
Bit-7
Bit-6
Bit-5
Bit-4
Bit-3
Bit-2
Bit-1
Bit-0
001
DLM
RD/WR
Bit-7
Bit-6
Bit-5
Bit-4
Bit-3
Bit-2
Bit-1
Bit-0
000
DREV
RD
Bit-7
Bit-6
Bit-5
Bit-4
Bit-3
Bit-2
Bit-1
Bit-0
001
DVID
RD
0
0
0
0
1
0
1
0
LCR[7] = 1
LCR ≠ 0xBF
DLL=0x00
DLM=0x00
Enhanced Registers
000
TRG
WR
Bit-7
Bit-6
Bit-5
Bit-4
Bit-3
Bit-2
Bit-1
Bit-0
000
FC
RD
Bit-7
Bit-6
Bit-5
Bit-4
Bit-3
Bit-2
Bit-1
Bit-0
RX/TX
Mode
SCPAD
Swap
Trig
Table
Bit-1
Trig
Table
Bit-0
Auto
RS485
Direction
Control
RX IR
Input
Inv.
Auto
RTS
Hyst
Bit-1
Auto
RTS
Hyst
Bit-0
Auto
CTS
Enable
Auto
RTS
Enable
Special
Char
Select
Enable
Software
Flow
Cntl
Bit-3
Software
Flow
Cntl
Bit-2
Software
Flow
Cntl
Bit-1
Software
Flow
Cntl
Bit-0
001
010
FCTR RD/WR
EFR
RD/WR
IER [7:4],
ISR [5:4],
FCR[5:4],
MCR[7:5]
100
XON1 RD/WR
Bit-7
Bit-6
Bit-5
Bit-4
Bit-3
Bit-2
Bit-1
Bit-0
101
XON2 RD/WR
Bit-7
Bit-6
Bit-5
Bit-4
Bit-3
Bit-2
Bit-1
Bit-0
110
XOFF1 RD/WR
Bit-7
Bit-6
Bit-5
Bit-4
Bit-3
Bit-2
Bit-1
Bit-0
111
XOFF2 RD/WR
Bit-7
Bit-6
Bit-5
Bit-4
Bit-3
Bit-2
Bit-1
Bit-0
LCR=0XBF
4.0 INTERNAL REGISTER DESCRIPTIONS
4.1
Receive Holding Register (RHR) - Read- Only
See “Receiver” on page 12.
4.2
Transmit Holding Register (THR) - Write-Only
See “Transmitter” on page 11.
4.3
Interrupt Enable Register (IER) - Read/Write
The Interrupt Enable Register (IER) masks the interrupts from receive data ready, transmit empty, line status
and modem status registers. These interrupts are reported in the Interrupt Status Register (ISR).
21
áç
XR16L2750
2.25V TO 5.5V DUART WITH 64-BYTE FIFO
REV. 1.0.0
4.3.1
IER versus Receive FIFO Interrupt Mode Operation
When the receive FIFO (FCR BIT-0 = 1) and receive interrupts (IER BIT-0 = 1) are enabled, the RHR interrupts
(see ISR bits 2 and 3) status will reflect the following:
A. The receive data available interrupts are issued to the host when the FIFO has reached the programmed
trigger level. It will be cleared when the FIFO drops below the programmed trigger level.
B. FIFO level will be reflected in the ISR register when the FIFO trigger level is reached. Both the ISR register
status bit and the interrupt will be cleared when the FIFO drops below the trigger level.
C. The receive data ready bit (LSR BIT-0) is set as soon as a character is transferred from the shift register to
the receive FIFO. It is reset when the FIFO is empty.
4.3.2
IER versus Receive/Transmit FIFO Polled Mode Operation
When FCR BIT-0 equals a logic 1 for FIFO enable; resetting IER bits 0-3 enables the XR16L2750 in the FIFO
polled mode of operation. Since the receiver and transmitter have separate bits in the LSR either or both can
be used in the polled mode by selecting respective transmit or receive control bit(s).
A. LSR BIT-0 indicates there is data in RHR or RX FIFO.
B. LSR BIT-1 indicates an overrun error has occurred and that data in the FIFO may not be valid.
C. LSR BIT 2-4 provides the type of receive data errors encountered for the data byte in RHR, if any.
D. LSR BIT-5 indicates THR is empty.
E. LSR BIT-6 indicates when both the transmit FIFO and TSR are empty.
F. LSR BIT-7 indicates a data error in at least one character in the RX FIFO.
IER[0]: RHR Interrupt Enable
The receive data ready interrupt will be issued when RHR has a data character in the non-FIFO mode or when
the receive FIFO has reached the programmed trigger level in the FIFO mode.
Logic 0 = Disable the receive data ready interrupt (default).
Logic 1 = Enable the receiver data ready interrupt.
IER[1]: THR Interrupt Enable
This bit enables the Transmit Ready interrupt which is issued whenever the THR becomes empty in the nonFIFO mode or when data in the FIFO falls below the programmed trigger level in the FIFO mode. If the THR is
empty when this bit is enabled, an interrupt will be generated.
Logic 0 = Disable Transmit Ready interrupt (default).
Logic 1 = Enable Transmit Ready interrupt.
IER[2]: Receive Line Status Interrupt Enable
If any of the LSR register bits 1, 2, 3 or 4 is a logic 1, it will generate an interrupt to inform the host controller
about the error status of the current data byte in FIFO. LSR bit-1 generates an interrupt immediately when the
character has been received. LSR bits 2-4 generate an interrupt when the character with errors is read out of
the FIFO (default). Instead, LSR bits 2-4 can be programmed to generate an interrupt immediately, by setting
EMSR bit-6 to a logic 1.
• Logic 0 = Disable the receiver line status interrupt (default).
• Logic 1 = Enable the receiver line status interrupt.
IER[3]: Modem Status Interrupt Enable
• Logic 0 = Disable the modem status register interrupt (default).
• Logic 1 = Enable the modem status register interrupt.
IER[4]: Sleep Mode Enable (requires EFR bit-4 = 1)
• Logic 0 = Disable Sleep Mode (default).
• Logic 1 = Enable Sleep Mode. See Sleep Mode section for further details.
22
áç
XR16L2750
2.25V TO 5.5V DUART WITH 64-BYTE FIFO
REV. 1.0.0
IER[5]: Xoff Interrupt Enable (requires EFR bit-4=1)
• Logic 0 = Disable the software flow control, receive Xoff interrupt. (default)
• Logic 1 = Enable the software flow control, receive Xoff interrupt. See Software Flow Control section for
details.
IER[6]: RTS# Output Interrupt Enable (requires EFR bit-4=1)
• Logic 0 = Disable the RTS# interrupt (default).
• Logic 1 = Enable the RTS# interrupt. The UART issues an interrupt when the RTS# pin makes a transition
from low to high.
IER[7]: CTS# Input Interrupt Enable (requires EFR bit-4=1)
• Logic 0 = Disable the CTS# interrupt (default).
• Logic 1 = Enable the CTS# interrupt. The UART issues an interrupt when CTS# pin makes a transition from
low to high.
4.4
Interrupt Status Register (ISR) - Read-Only
The UART provides multiple levels of prioritized interrupts to minimize external software interaction. The
Interrupt Status Register (ISR) provides the user with six interrupt status bits. Performing a read cycle on the
ISR will give the user the current highest pending interrupt level to be serviced, others are queued up to be
serviced next. No other interrupts are acknowledged until the pending interrupt is serviced. The Interrupt
Source Table, Table 9, shows the data values (bit 0-5) for the interrupt priority levels and the interrupt sources
associated with each of these interrupt levels.
4.4.1
Interrupt Generation:
• LSR is by any of the LSR bits 1, 2, 3 and 4.
• RXRDY is by RX trigger level.
• RXRDY Time-out is by a 4-char plus 12 bits delay timer.
• TXRDY is by TX trigger level or TX FIFO empty (or transmitter empty in auto RS-485 control).
• MSR is by any of the MSR bits 0, 1, 2 and 3.
• Receive Xoff/Special character is by detection of a Xoff or Special character.
• CTS# is when its transmitter toggles the input pin (from low to high) during auto CTS flow control enabled by
EFR bit-7.
• RTS# is when its receiver toggles the output pin (from low to high) during auto RTS flow control enabled by
EFR bit-6.
4.4.2
Interrupt Clearing:
• LSR interrupt is cleared by a read to the LSR register (but flags and tags not cleared until character(s) that
generated the interrupt(s) has been emptied or cleared from FIFO).
• RXRDY interrupt is cleared by reading data until FIFO falls below the trigger level.
• RXRDY Time-out interrupt is cleared by reading RHR.
• TXRDY interrupt is cleared by a read to the ISR register or writing to THR.
• MSR interrupt is cleared by a read to the MSR register.
• Xoff or Special character interrupt is cleared by a read to ISR.
• RTS# and CTS# flow control interrupts are cleared by a read to the MSR register.
23
áç
XR16L2750
2.25V TO 5.5V DUART WITH 64-BYTE FIFO
REV. 1.0.0
]
TABLE 9: INTERRUPT SOURCE AND PRIORITY LEVEL
PRIORITY
ISR REGISTER STATUS BITS
SOURCE OF INTERRUPT
LEVEL
BIT-5
BIT-4
BIT-3
BIT-2
BIT-1
BIT-0
1
0
0
0
1
1
0
LSR (Receiver Line Status Register)
2
0
0
1
1
0
0
RXRDY (Receive Data Time-out)
3
0
0
0
1
0
0
RXRDY (Received Data Ready)
4
0
0
0
0
1
0
TXRDY (Transmit Ready)
5
0
0
0
0
0
0
MSR (Modem Status Register)
6
0
1
0
0
0
0
RXRDY (Received Xoff or Special character)
7
1
0
0
0
0
0
CTS#, RTS# change of state
-
0
0
0
0
0
1
None (default)
ISR[0]: Interrupt Status
• Logic 0 = An interrupt is pending and the ISR contents may be used as a pointer to the appropriate interrupt
service routine.
• Logic 1 = No interrupt pending (default condition).
ISR[3:1]: Interrupt Status
These bits indicate the source for a pending interrupt at interrupt priority levels (See Interrupt Source Table 9).
ISR[5:4]: Interrupt Status
These bits are enabled when EFR bit-4 is set to a logic 1. ISR bit-4 indicates that the receiver detected a data
match of the Xoff character(s). Note that once set to a logic 1, the ISR bit-4 will stay a logic 1 until a Xon
character is received. ISR bit-5 indicates that CTS# or RTS# has changed state.
ISR[7:6]: FIFO Enable Status
These bits are set to a logic 0 when the FIFOs are disabled. They are set to a logic 1 when the FIFOs are
enabled.
4.5
FIFO Control Register (FCR) - Write-Only
This register is used to enable the FIFOs, clear the FIFOs, set the transmit/receive FIFO trigger levels, and
select the DMA mode. The DMA, and FIFO modes are defined as follows:
FCR[0]: TX and RX FIFO Enable
• Logic 0 = Disable the transmit and receive FIFO (default).
• Logic 1 = Enable the transmit and receive FIFOs. This bit must be set to logic 1 when other FCR bits are
written or they will not be programmed.
FCR[1]: RX FIFO Reset
This bit is only active when FCR bit-0 is a ‘1’.
• Logic 0 = No receive FIFO reset (default)
• Logic 1 = Reset the receive FIFO pointers and FIFO level counter logic (the receive shift register is not
cleared or altered). This bit will return to a logic 0 after resetting the FIFO.
24
áç
XR16L2750
2.25V TO 5.5V DUART WITH 64-BYTE FIFO
REV. 1.0.0
FCR[2]: TX FIFO Reset
This bit is only active when FCR bit-0 is a ‘1’.
• Logic 0 = No transmit FIFO reset (default).
• Logic 1 = Reset the transmit FIFO pointers and FIFO level counter logic (the transmit shift register is not
cleared or altered). This bit will return to a logic 0 after resetting the FIFO.
FCR[3]: DMA Mode Select
Controls the behavior of the TXRDY# and RXRDY# pins. See DMA operation section for details.
• Logic 0 = Normal Operation (default).
• Logic 1 = DMA Mode.
FCR[5:4]: Transmit FIFO Trigger Select
(logic 0 = default, TX trigger level = one)
These 2 bits set the trigger level for the transmit FIFO. The UART will issue a transmit interrupt when the
number of characters in the FIFO falls below the selected trigger level, or when it gets empty in case that the
FIFO did not get filled over the trigger level on last re-load. Table 10 below shows the selections. EFR bit-4
must be set to ‘1’ before these bits can be accessed. Note that the receiver and the transmitter cannot use
different trigger tables. Whichever selection is made last applies to both the RX and TX side.
25
áç
XR16L2750
2.25V TO 5.5V DUART WITH 64-BYTE FIFO
REV. 1.0.0
FCR[7:6]: Receive FIFO Trigger Select
(logic 0 = default, RX trigger level =1)
The FCTR Bits 5-4 are associated with these 2 bits. These 2 bits are used to set the trigger level for the receive
FIFO. The UART will issue a receive interrupt when the number of the characters in the FIFO crosses the
trigger level. Table 10 shows the complete selections. Note that the receiver and the transmitter cannot use
different trigger tables. Whichever selection is made last applies to both the RX and TX side.
TABLE 10: TRANSMIT AND RECEIVE FIFO TRIGGER LEVEL SELECTION
FCTR
BIT-5
FCTR
BIT-4
0
0
0
FCR
BIT-7
FCR
BIT-6
0
0
1
1
0
1
0
1
1
1
FCR
0
0
0
1
0
1
X
X
1 (default)
0
1
0
1
COMPATIBILITY
Table-A. 16C550, 16C2550,
16C2552, 16C554, 16C580
compatible.
16
8
24
30
Table-B. 16C650A compatible.
8
16
32
56
Table-C. 16C654 compatible.
8
16
24
28
0
0
1
1
0
0
1
1
TRANSMIT
RECEIVE
TRIGGER LEVEL TRIGGER LEVEL
1 (default)
4
8
14
0
1
0
1
0
1
BIT-4
0
0
1
1
0
0
1
1
1
FCR
BIT-5
0
1
0
1
8
16
56
60
X
X
Programmable Programmable Table-D. 16C850, 16L2752,
16C2850, 16C2852, 16C854,
via TRG
via TRG
16C864, 16C872 compatible.
register.
register.
FCTR[7] = 0. FCTR[7] = 1.
26
áç
XR16L2750
2.25V TO 5.5V DUART WITH 64-BYTE FIFO
REV. 1.0.0
4.6
Line Control Register (LCR) - Read/Write
The Line Control Register is used to specify the asynchronous data communication format. The word or
character length, the number of stop bits, and the parity are selected by writing the appropriate bits in this
register.
LCR[1:0]: TX and RX Word Length Select
These two bits specify the word length to be transmitted or received.
BIT-1
BIT-0
WORD LENGTH
0
0
5 (default)
0
1
6
1
0
7
1
1
8
LCR[2]: TX and RX Stop-bit Length Select
The length of stop bit is specified by this bit in conjunction with the programmed word length.
LENGTH
STOP BIT LENGTH
(BIT TIME(S))
0
5,6,7,8
1 (default)
1
5
1-1/2
1
6,7,8
2
BIT-2
WORD
LCR[3]: TX and RX Parity Select
Parity or no parity can be selected via this bit. The parity bit is a simple way used in communications for data
integrity check. See Table 11 for parity selection summary below.
• Logic 0 = No parity.
• Logic 1 = A parity bit is generated during the transmission while the receiver checks for parity error of the
data character received.
LCR[4]: TX and RX Parity Select
If the parity bit is enabled with LCR bit-3 set to a logic 1, LCR BIT-4 selects the even or odd parity format.
• Logic 0 = ODD Parity is generated by forcing an odd number of logic 1’s in the transmitted character. The
receiver must be programmed to check the same format (default).
• Logic 1 = EVEN Parity is generated by forcing an even number of logic 1’s in the transmitted character. The
receiver must be programmed to check the same format.
LCR[5]: TX and RX Parity Select
If the parity bit is enabled, LCR BIT-5 selects the forced parity format.
• LCR BIT-5 = logic 0, parity is not forced (default).
• LCR BIT-5 = logic 1 and LCR BIT-4 = logic 0, parity bit is forced to a logical 1 for the transmit and receive
data.
• LCR BIT-5 = logic 1 and LCR BIT-4 = logic 1, parity bit is forced to a logical 0 for the transmit and receive
data.
27
áç
XR16L2750
2.25V TO 5.5V DUART WITH 64-BYTE FIFO
REV. 1.0.0
TABLE 11: PARITY SELECTION
LCR BIT-5 LCR BIT-4 LCR BIT-3
PARITY SELECTION
X
X
0
No parity
0
0
1
Odd parity
0
1
1
Even parity
1
0
1
Force parity to mark,
“1”
1
1
1
Forced parity to
space, “0”
LCR[6]: Transmit Break Enable
When enabled, the Break control bit causes a break condition to be transmitted (the TX output is forced to a
“space’, logic 0, state). This condition remains, until disabled by setting LCR bit-6 to a logic 0.
• Logic 0 = No TX break condition. (default)
• Logic 1 = Forces the transmitter output (TX) to a “space”, logic 0, for alerting the remote receiver of a line
break condition.
LCR[7]: Baud Rate Divisors Enable
Baud rate generator divisor (DLL/DLM) enable.
• Logic 0 = Data registers are selected. (default)
• Logic 1 = Divisor latch registers are selected.
4.7
Modem Control Register (MCR) or General Purpose Outputs Control - Read/Write
The MCR register is used for controlling the serial/modem interface signals or general purpose inputs/outputs.
MCR[0]: DTR# Output
The DTR# pin is a modem control output. If the modem interface is not used, this output may be used as a
general purpose output.
• Logic 0 = Force DTR# output to a logic 1 (default).
• Logic 1 = Force DTR# output to a logic 0.
MCR[1]: RTS# Output
The RTS# pin is a modem control output and may be used for automatic hardware flow control by enabled by
EFR bit-6. If the modem interface is not used, this output may be used as a general purpose output.
• Logic 0 = Force RTS# output to a logic 1 (default).
• Logic 1 = Force RTS# output to a logic 0.
MCR[2]: Reserved
OP1# is not available as an output pin on the 2750. But it is available for use during Internal Loopback Mode. In
the Loopback Mode, this bit is used to write the state of the modem RI# interface signal.
MCR[3]: OP2# Output / INT Output Enable
This bit enables or disables the operation of INT, interrupt output. If INT output is not used, OP2# can be used
as a general purpose output.
• Logic 0 = INT (A-B) outputs disabled (three state mode) and OP2# output set to a logic 1 (default).
• Logic 1 = INT (A-B) outputs enabled (active mode) and OP2# output set to a logic 0.
28
áç
XR16L2750
2.25V TO 5.5V DUART WITH 64-BYTE FIFO
REV. 1.0.0
MCR[4]: Internal Loopback Enable
• Logic 0 = Disable loopback mode (default).
• Logic 1 = Enable local loopback mode, see loopback section and Figure 13.
MCR[5]: Xon-Any Enable
• Logic 0 = Disable Xon-Any function (for 16C550 compatibility, default).
• Logic 1 = Enable Xon-Any function. In this mode, any RX character received will resume transmit operation.
The RX character will be loaded into the RX FIFO, unless the RX character is an Xon or Xoff character and
the 2750 is programmed to use the Xon/Xoff flow control.
MCR[6]: Infrared Encoder/Decoder Enable
• Logic 0 = Enable the standard modem receive and transmit input/output interface. (Default)
• Logic 1 = Enable infrared IrDA receive and transmit inputs/outputs. The TX/RX output/input are routed to the
infrared encoder/decoder. The data input and output levels conform to the IrDA infrared interface
requirement. While in this mode, the infrared TX output will be a logic 0 during idle data conditions.
MCR[7]: Clock Prescaler Select
• Logic 0 = Divide by one. The input clock from the crystal or external clock is fed directly to the Programmable
Baud Rate Generator without further modification, i.e., divide by one (default).
• Logic 1 = Divide by four. The prescaler divides the input clock from the crystal or external clock by four and
feeds it to the Programmable Baud Rate Generator, hence, data rates become one forth.
4.8
Line Status Register (LSR) - Read Only
This register provides the status of data transfers between the UART and the host.
LSR[0]: Receive Data Ready Indicator
• Logic 0 = No data in receive holding register or FIFO (default).
• Logic 1 = Data has been received and is saved in the receive holding register or FIFO.
LSR[1]: Receiver Overrun Error Flag
• Logic 0 = No overrun error (default).
• Logic 1 = Overrun error. A data overrun error condition occurred in the receive shift register. This happens
when additional data arrives while the FIFO is full. In this case the previous data in the receive shift register is
overwritten. Note that under this condition the data byte in the receive shift register is not transferred into the
FIFO, therefore the data in the FIFO is not corrupted by the error.
LSR[2]: Receive Data Parity Error Tag
• Logic 0 = No parity error (default).
• Logic 1 = Parity error. The receive character in RHR does not have correct parity information and is suspect.
This error is associated with the character available for reading in RHR.
LSR[3]: Receive Data Framing Error Tag
• Logic 0 = No framing error (default).
• Logic 1 = Framing error. The receive character did not have a valid stop bit(s). This error is associated with
the character available for reading in RHR.
LSR[4]: Receive Break Error Tag
• Logic 0 = No break condition (default).
• Logic 1 = The receiver received a break signal (RX was a logic 0 for at least one character frame time). In the
FIFO mode, only one break character is loaded into the FIFO. The break indication remains until the RX input
returns to the idle condition, “mark” or logic 1.
29
áç
XR16L2750
2.25V TO 5.5V DUART WITH 64-BYTE FIFO
REV. 1.0.0
LSR[5]: Transmit Holding Register Empty Flag
This bit is the Transmit Holding Register Empty indicator. The THR bit is set to a logic 1 when the last data byte
is transferred from the transmit holding register to the transmit shift register. The bit is reset to logic 0
concurrently with the data loading to the transmit holding register by the host. In the FIFO mode this bit is set
when the transmit FIFO is empty, it is cleared when the transmit FIFO contains at least 1 byte.
LSR[6]: THR and TSR Empty Flag
This bit is set to a logic 1 whenever the transmitter goes idle. It is set to logic 0 whenever either the THR or TSR
contains a data character. In the FIFO mode this bit is set to a logic 1 whenever the transmit FIFO and transmit
shift register are both empty.
LSR[7]: Receive FIFO Data Error Flag
• Logic 0 = No FIFO error (default).
• Logic 1 = A global indicator for the sum of all error bits in the RX FIFO. At least one parity error, framing error
or break indication is in the FIFO data. This bit clears when there is no more error(s) in any of the bytes in the
RX FIFO.
4.9
Modem Status Register (MSR) - Read Only
This register provides the current state of the modem interface input signals. Lower four bits of this register are
used to indicate the changed information. These bits are set to a logic 1 whenever a signal from the modem
changes state. These bits may be used for general purpose inputs when they are not used with modem
signals.
MSR[0]: Delta CTS# Input Flag
• Logic 0 = No change on CTS# input (default).
• Logic 1 = The CTS# input has changed state since the last time it was monitored. A modem status interrupt
will be generated if MSR interrupt is enabled (IER bit-3).
MSR[1]: Delta DSR# Input Flag
• Logic 0 = No change on DSR# input (default).
• Logic 1 = The DSR# input has changed state since the last time it was monitored. A modem status interrupt
will be generated if MSR interrupt is enabled (IER bit-3).
MSR[2]: Delta RI# Input Flag
• Logic 0 = No change on RI# input (default).
• Logic 1 = The RI# input has changed from a logic 0 to a logic 1, ending of the ringing signal. A modem status
interrupt will be generated if MSR interrupt is enabled (IER bit-3).
MSR[3]: Delta CD# Input Flag
• Logic 0 = No change on CD# input (default).
• Logic 1 = Indicates that the CD# input has changed state since the last time it was monitored. A modem
status interrupt will be generated if MSR interrupt is enabled (IER bit-3).
MSR[4]: CTS Input Status
CTS# pin may function as automatic hardware flow control signal input if it is enabled and selected by Auto
CTS (EFR bit-7). Auto CTS flow control allows starting and stopping of local data transmissions based on the
modem CTS# signal. A logic 1 on the CTS# pin will stop UART transmitter as soon as the current character
has finished transmission, and a logic 0 will resume data transmission. Normally MSR bit-4 bit is the
compliment of the CTS# input. However in the loopback mode, this bit is equivalent to the RTS# bit in the MCR
register. The CTS# input may be used as a general purpose input when the modem interface is not used.
MSR[5]: DSR Input Status
DSR# (active high, logical 1). Normally this bit is the compliment of the DSR# input. In the loopback mode, this
bit is equivalent to the DTR# bit in the MCR register. The DSR# input may be used as a general purpose input
when the modem interface is not used.
30
áç
XR16L2750
2.25V TO 5.5V DUART WITH 64-BYTE FIFO
REV. 1.0.0
MSR[6]: RI Input Status
RI# (active high, logical 1). Normally this bit is the compliment of the RI# input. In the loopback mode this bit is
equivalent to bit-2 in the MCR register. The RI# input may be used as a general purpose input when the
modem interface is not used.
MSR[7]: CD Input Status
CD# (active high, logical 1). Normally this bit is the compliment of the CD# input. In the loopback mode this bit
is equivalent to bit-3 in the MCR register. The CD# input may be used as a general purpose input when the
modem interface is not used.
4.10
Scratch Pad Register (SPR) - Read/Write
This is a 8-bit general purpose register for the user to store temporary data. The content of this register is
preserved during sleep mode but becomes 0xFF (default) after a reset or a power off-on cycle.
4.11
Enhanced Mode Select Register (EMSR)
This register replaces SPR (during a Write) and is accessible only when FCTR[6] = 1.
EMSR[1:0]: Receive/Transmit FIFO Level Count (Write-Only)
When Scratchpad Swap (FCTR[6]) is asserted, EMSR bits 1-0 controls what mode the FIFO Level Counter is
operating in.
TABLE 12: SCRATCHPAD SWAP SELECTION
FCTR[6] EMSR[1]
EMSR[0] Scratchpad is
0
X
X
Scratchpad
1
X
0
RX FIFO Level Counter
Mode
1
0
1
TX FIFO Level Counter
Mode
1
1
1
Alternate RX/TX FIFO
Counter Mode
During Alternate RX/TX FIFO Level Counter Mode, the first value read after EMSR bits 1-0 have been asserted
will always be the RX FIFO Level Counter. The second value read will correspond with the TX FIFO Level
Counter. The next value will be the RX FIFO Level Counter again, then the TX FIFO Level Counter and so on
and so forth.
EMSR[2]: Reserved
EMSR[3]: Automatic RS485 Half-Duplex Control Output Inversion
• Logic 0 = RTS# output is a logic 0 during TX and a logic 1 during RX (default, compatible with 16C2850).
• Logic 1 = RTS# output is a logic 1 during TX and a logic 0 during RX.
31
áç
XR16L2750
2.25V TO 5.5V DUART WITH 64-BYTE FIFO
REV. 1.0.0
EMSR[5:4]: Extended RTS Hysteresis
TABLE 13: AUTO RTS HYSTERESIS
EMSR
BIT-5
EMSR
BIT-4
FCTR
BIT-1
FCTR
BIT-0
RTS#
HYSTERESIS
(CHARACTERS)
0
0
0
0
0
0
0
0
0
0
1
1
0
1
0
1
0
±4
±6
±8
0
0
0
0
1
1
1
1
0
0
1
1
0
1
0
1
±8
±16
±24
±32
1
1
1
1
0
0
0
0
0
0
1
1
0
1
0
1
±40
±44
±48
±52
1
1
1
1
1
1
1
1
0
0
1
1
0
1
0
1
±12
±20
±28
±36
EMSR[6]: LSR Interrupt Mode
• Logic 0 = LSR Interrupt Delayed (for 16C2550 compatibility, default). LSR bits 2, 3, and 4 will generate an
interrupt when the character with the error is in the RHR.
• Logic 1 = LSR Interrupt Immediate. LSR bits 2, 3, and 4 will generate an interrupt as soon as the character is
received into the FIFO.
EMSR[7]: 16X Sampling Rate Mode
Logic 0 = 8X Sampling Rate.
Logic 1 = 16X Sampling Rate (for 16C550 compatibility, default).
4.12
FIFO Level Register (FLVL) - Read-Only
The FIFO Level Register replaces the Scratchpad Register (during a Read) when FCTR[6] = 1. Note that this is
not identical to the FIFO Data Count Register which can be accessed when LCR = 0xBF.
FLVL[7:0]: FIFO Level Register
This register provides the FIFO counter level for the RX FIFO or the TX FIFO or both depending on EMSR[1:0].
See Table 12 for details.
4.13
Baud Rate Generator Registers (DLL and DLM) - Read/Write
The concatenation of the contents of DLM and DLL gives the 16-bit divisor value which is used to calculate the
baud rate:
• Baud Rate = (Clock Frequency / 16) / Divisor
See MCR bit-7 and the baud rate table also.
4.14
Device Identification Register (DVID) - Read Only
This register contains the device ID (0x0A for XR16L2750). Prior to reading this register, DLL and DLM should
be set to 0x00.
32
áç
XR16L2750
2.25V TO 5.5V DUART WITH 64-BYTE FIFO
REV. 1.0.0
4.15
Device Revision Register (DREV) - Read Only
This register contains the device revision information. For example, 0x01 means revision A. Prior to reading
this register, DLL and DLM should be set to 0x00.
4.16
Trigger Level Register (TRG) - Write-Only
User Programmable Transmit/Receive Trigger Level Register.
TRG[7:0]: Trigger Level Register
These bits are used to program desired trigger levels when trigger Table-D is selected. FCTR bit-7 selects
between programming the RX Trigger Level (a logic 0) and the TX Trigger Level (a logic 1).
4.17
RX/TX FIFO Level Count Register (FC) - Read-Only
This register is accessible when LCR = 0xBF. Note that this register is not identical to the FIFO Level Count
Register which is located in the general register set when FCTR bit-6 = 1 (Scratchpad Register Swap). It is
suggested to read the FIFO Level Count Register at the Scratchpad Register location when FCTR bit-6 = 1.
See Table 12.
FC[7:0]: RX/TX FIFO Level Count
Receive/Transmit FIFO Level Count. Number of characters in Receiver FIFO (FCTR[7] = 0) or Transmitter FIFO
(FCTR[7] = 1) can be read via this register.
4.18
Feature Control Register (FCTR) - Read/Write
This register controls the XR16L2750 new functions that are not available in ST16C2450 or ST16C2550.
FCTR[1:0]: RTS Hysteresis
User selectable RTS# hysteresis levels for hardware flow control application. After reset, these bits are set to
“0” to select the next trigger level for hardware flow control. See Table 13 for more details.
FCTR[2]: IrDa RX Inversion
• Logic 0 = Select RX input as encoded IrDa data (Idle state will be logic 0).
• Logic 1 = Select RX input as inverted encoded IrDa data (Idle state will be logic 1).
FCTR[3]: Auto RS-485 Direction Control
• Logic 0 = Standard ST16C550 mode. Transmitter generates an interrupt when transmit holding register
becomes empty and transmit shift register is shifting data out.
• Logic 1 = Enable Auto RS485 Direction Control function. The direction control signal, RTS# pin, changes its
output logic state from low to high one bit time after the last stop bit of the last character is shifted out. Also,
the Transmit interrupt generation is delayed until the transmitter shift register becomes empty. The RTS#
output pin will automatically return to a logic low when a data byte is loaded into the TX FIFO. However,
RTS# behavior can be inverted by setting EMSR[3] = 1.
FCTR[5:4]: Transmit/Receive Trigger Table Select
See Table 10 for more details.
TABLE 14: TRIGGER TABLE SELECT
FCTR
BIT-5
FCTR
BIT-4
0
0
Table-A (TX/RX)
0
1
Table-B (TX/RX)
1
0
Table-C (TX/RX)
1
1
Table-D (TX/RX)
TABLE
33
áç
XR16L2750
2.25V TO 5.5V DUART WITH 64-BYTE FIFO
REV. 1.0.0
FCTR[6]: Scratchpad Swap
• Logic 0 = Scratch Pad register is selected as general read and write register. ST16C550 compatible mode.
• Logic 1 = FIFO Count register (Read-Only), Enhanced Mode Select Register (Write-Only). Number of
characters in transmit or receive FIFO can be read via scratch pad register when this bit is set. Enhanced
Mode Select Register is selected when it is written into.
FCTR[7]: Programmable Trigger Register Select
• Logic 0 = Registers TRG and FC selected for RX.
• Logic 1 = Registers TRG and FC selected for TX.
4.19
Enhanced Feature Register (EFR)
Enhanced features are enabled or disabled using this register. Bit 0-3 provide single or dual consecutive
character software flow control selection (see Table 15). When the Xon1 and Xon2 and Xoff1 and Xoff2 modes
are selected, the double 8-bit words are concatenated into two sequential characters. Caution: note that
whenever changing the TX or RX flow control bits, always reset all bits back to logic 0 (disable) before
programming a new setting.
EFR[3:0]: Software Flow Control Select
Single character and dual sequential characters software flow control is supported. Combinations of software
flow control can be selected by programming these bits.
TABLE 15: SOFTWARE FLOW CONTROL FUNCTIONS
EFR BIT-3
CONT-3
EFR BIT-2
CONT-2
EFR BIT-1
CONT-1
EFR BIT-0
CONT-0
0
0
0
0
No TX and RX flow control (default and reset)
0
0
X
X
No transmit flow control
1
0
X
X
Transmit Xon1, Xoff1
0
1
X
X
Transmit Xon2, Xoff2
1
1
X
X
Transmit Xon1 and Xon2, Xoff1 and Xoff2
X
X
0
0
No receive flow control
X
X
1
0
Receiver compares Xon1, Xoff1
X
X
0
1
Receiver compares Xon2, Xoff2
1
0
1
1
Transmit Xon1, Xoff1
Receiver compares Xon1 or Xon2, Xoff1 or Xoff2
0
1
1
1
Transmit Xon2, Xoff2
Receiver compares Xon1 or Xon2, Xoff1 or Xoff2
1
1
1
1
Transmit Xon1 and Xon2, Xoff1 and Xoff2,
Receiver compares Xon1 and Xon2, Xoff1 and Xoff2
0
0
1
1
No transmit flow control,
Receiver compares Xon1 and Xon2, Xoff1 and Xoff2
34
TRANSMIT AND RECEIVE SOFTWARE FLOW CONTROL
áç
XR16L2750
2.25V TO 5.5V DUART WITH 64-BYTE FIFO
REV. 1.0.0
EFR[4]: Enhanced Function Bits Enable
Enhanced function control bit. This bit enables IER bits 4-7, ISR bits 4-5, FCR bits 4-5, and MCR bits 5-7 to be
modified. After modifying any enhanced bits, EFR bit-4 can be set to a logic 0 to latch the new values. This
feature prevents legacy software from altering or overwriting the enhanced functions once set. Normally, it is
recommended to leave it enabled, logic 1.
• Logic 0 = modification disable/latch enhanced features. IER bits 4-7, ISR bits 4-5, FCR bits 4-5, and MCR
bits 5-7 are saved to retain the user settings. After a reset, the IER bits 4-7, ISR bits 4-5, FCR bits 4-5, and
MCR bits 5-7are set to a logic 0 to be compatible with ST16C550 mode (default).
• Logic 1 = Enables the above-mentioned register bits to be modified by the user.
EFR[5]: Special Character Detect Enable
• Logic 0 = Special Character Detect Disabled (default).
• Logic 1 = Special Character Detect Enabled. The UART compares each incoming receive character with
data in Xoff-2 register. If a match exists, the receive data will be transferred to FIFO and ISR bit-4 will be set
to indicate detection of the special character. Bit-0 corresponds with the LSB bit of the receive character. If
flow control is set for comparing Xon1, Xoff1 (EFR [1:0]= ‘10’) then flow control and special character work
normally. However, if flow control is set for comparing Xon2, Xoff2 (EFR[1:0]= ‘01’) then flow control works
normally, but Xoff2 will not go to the FIFO, and will generate an Xoff interrupt and a special character
interrupt, if enabled via IER bit-5.
EFR[6]: Auto RTS Flow Control Enable
RTS# output may be used for hardware flow control by setting EFR bit-6 to logic 1. When Auto RTS is selected,
an interrupt will be generated when the receive FIFO is filled to the programmed trigger level and RTS deasserts to a logic 1 at the next upper trigger level or hysteresis level. RTS# will return to a logic 0 when FIFO
data falls below the next lower trigger level. The RTS# output must be asserted (logic 0) before the auto RTS
can take effect. RTS# pin will function as a general purpose output when hardware flow control is disabled.
• Logic 0 = Automatic RTS flow control is disabled (default).
• Logic 1 = Enable Automatic RTS flow control.
EFR[7]: Auto CTS Flow Control Enable
Automatic CTS Flow Control.
• Logic 0 = Automatic CTS flow control is disabled (default).
• Logic 1 = Enable Automatic CTS flow control. Data transmission stops when CTS# input de-asserts to logic
1. Data transmission resumes when CTS# returns to a logic 0.
4.19.1
Software Flow Control Registers (XOFF1, XOFF2, XON1, XON2) - Read/Write
These registers are used as the programmable software flow control characters xoff1, xoff2, xon1, and xon2.
For more details, see Table 6.
35
áç
XR16L2750
2.25V TO 5.5V DUART WITH 64-BYTE FIFO
REV. 1.0.0
TABLE 16: UART RESET CONDITIONS FOR CHANNEL A AND B
REGISTERS
RESET STATE
DLM and DLL
DLM = 0x00 and DLL = 0x01. Only resets to these values during a
power up. They do not reset when the Reset Pin is asserted.
RHR
Bits 7-0 = 0xXX
THR
Bits 7-0 = 0xXX
IER
Bits 7-0 = 0x00
FCR
Bits 7-0 = 0x00
ISR
Bits 7-0 = 0x01
LCR
Bits 7-0 = 0x00
MCR
Bits 7-0 = 0x00
LSR
Bits 7-0 = 0x60
MSR
Bits 3-0 = Logic 0
Bits 7-4 = Logic levels of the inputs inverted
SPR
Bits 7-0 = 0xFF
EMSR
Bits 7-0 = 0x80
FLVL
Bits 7-0 = 0x00
EFR
Bits 7-0 = 0x00
XON1
Bits 7-0 = 0x00
XON2
Bits 7-0 = 0x00
XOFF1
Bits 7-0 = 0x00
XOFF2
Bits 7-0 = 0x00
FC
Bits 7-0 = 0x00
I/O SIGNALS
RESET STATE
TX
Logic 1
OP2#
Logic 1
RTS#
Logic 1
DTR#
Logic 1
RXRDY#
Logic 1
TXRDY#
Logic 0
INT
Three-State Condition
36
áç
XR16L2750
2.25V TO 5.5V DUART WITH 64-BYTE FIFO
REV. 1.0.0
ABSOLUTE MAXIMUM RATINGS
Power Supply Range
7 Volts
Voltage at Any Pin
GND-0.3V to 7V
Operating Temperature
-40o to +85oC
Storage Temperature
-65o to +150oC
Package Dissipation
500 mW
TYPICAL PACKAGE THERMAL RESISTANCE DATA (MARGIN OF ERROR: ± 15%)
Thermal Resistance (48-TQFP)
theta-ja =59oC/W, theta-jc = 16oC/W
Thermal Resistance (44-PLCC)
theta-ja = 50oC/W, theta-jc = 21oC/W
ELECTRICAL CHARACTERISTICS
DC ELECTRICAL CHARACTERISTICS
TA=0O TO 70OC (-40O TO +85OC FOR INDUSTRIAL GRADE PACKAGE), VCC IS 2.25V TO 5.5V
SYMBOL
PARAMETER
LIMITS
2.5V
MIN
MAX
LIMITS
3.3V
MIN
MAX
LIMITS
5.0V
MIN
MAX
UNITS
VILCK
Clock Input Low Level
-0.3
0.2
-0.3
0.6
-0.5
0.6
V
VIHCK
Clock Input High Level
2.0
VCC
2.4
VCC
3.0
VCC
V
VIL
Input Low Voltage
-0.3
0.6
-0.3
0.8
-0.5
0.8
V
VIH
Input High Voltage
2.0
5.5
2.0
5.5
2.2
5.5
V
VOL
Output Low Voltage
0.4
V
V
V
0.4
0.4
VOH
Output High Voltage
2.4
V
V
V
2.0
1.8
IIL
Input Low Leakage Current
±10
±10
±10
uA
IIH
Input High Leakage Current
±10
±10
±10
uA
CIN
Input Pin Capacitance
5
5
5
pF
ICC
Power Supply Current
1.2
2
5
mA
6
15
30
uA
ISLEEP
Sleep Current
CONDITIONS
IOL = 6 mA
IOL = 4 mA
IOL = 2 mA
IOH = -6 mA
IOH = -1 mA
IOH = -400 uA
See Test 1
Test 1: The following inputs must remain steady at VCC or GND state to minimize Sleep current: A0-A2, D0D7, IOR#, IOW#, CSA# and CSB#. Also, RXA and RXB inputs must idle at logic 1 state while asleep. Floating
inputs will result in sleep currents in the mA range.
37
áç
XR16L2750
2.25V TO 5.5V DUART WITH 64-BYTE FIFO
REV. 1.0.0
AC ELECTRICAL CHARACTERISTICS
TA=0O TO 70OC (-40O TO +85OC FOR INDUSTRIAL GRADE PACKAGE), VCC IS 2.25 TO 5.5V
SYMBOL
PARAMETER
LIMITS
2.5
MIN
MAX
LIMITS
3.3
MIN
MAX
50
50
LIMITS
5.0
MIN
UNIT
CLK
Clock Pulse Duration
OSC
Oscillator Frequency
16
20
24
MHz
OSC
External Clock Frequency
24
33
50
MHz
17
ns
TAS
Address Setup Time
15
10
5
ns
TAH
Address Hold Time
15
10
5
ns
TCS
Chip Select Width
66
66
50
ns
TRD
IOR# Strobe Width
50
35
25
ns
TDY
Read Cycle Delay
50
40
30
ns
TRDV
Data Access Time
TDD
Data Disable Time
0
TWR
IOW# Strobe Width
40
40
25
ns
TDY
Write Cycle Delay
50
40
30
ns
TDS
Data Setup Time
15
10
5
ns
TDH
Data Hold Time
15
10
5
ns
50
50
35
0
35
0
CONDITIONS
MAX
35
ns
35
ns
TWDO
Delay From IOW# To Output
50
50
40
ns
100 pF load
TMOD
Delay To Set Interrupt From
MODEM Input
50
40
35
ns
100 pF load
TRSI
Delay To Reset Interrupt
From IOR#
50
40
35
ns
100 pF load
TSSI
Delay From Stop To Set Interrupt
1
1
1
Bclk
TRRI
Delay From IOR# To Reset
Interrupt
50
45
40
ns
TSI
Delay From Stop To Interrupt
50
45
40
ns
TINT
Delay From Initial INT Reset
To Transmit Start
24
Bclk
TWRI
Delay From IOW# To Reset
Interrupt
50
45
40
ns
TSSR
Delay From Stop To Set
RXRDY#
1
1
1
Bclk
8
24
8
38
24
8
100 pF load
áç
XR16L2750
2.25V TO 5.5V DUART WITH 64-BYTE FIFO
REV. 1.0.0
AC ELECTRICAL CHARACTERISTICS
TA=0O TO 70OC (-40O TO +85OC FOR INDUSTRIAL GRADE PACKAGE), VCC IS 2.25 TO 5.5V
SYMBOL
LIMITS
2.5
MIN
MAX
PARAMETER
LIMITS
3.3
MIN
MAX
LIMITS
5.0
MIN
UNIT
MAX
TRR
Delay From IOR# To Reset
RXRDY#
50
45
40
ns
TWT
Delay From IOW# To Set
TXRDY#
50
45
40
ns
TSRT
Delay From Center of Start To
Reset TXRDY#
8
8
8
Bclk
TRST
Reset Pulse Width
40
N
Baud Rate Divisor
1
Bclk
Baud Clock
40
1
216-1
40
216-1
16X or 8X of data rate
FIGURE 14. CLOCK TIMING
CLK
CLK
EXTERNAL
CLOCK
OSC
39
1
ns
216-1
Hz
CONDITIONS
áç
XR16L2750
2.25V TO 5.5V DUART WITH 64-BYTE FIFO
REV. 1.0.0
FIGURE 15. MODEM INPUT/OUTPUT TIMING FOR CHANNELS A & B
IOW #
Active
T W DO
RTS#
DTR#
Change of state
Change of state
CD#
CTS#
DSR#
Change of state
Change of state
T MOD
T MOD
INT
Active
Active
Active
T RSI
IOR#
Active
Active
Active
T MOD
Change of state
RI#
FIGURE 16. DATA BUS READ TIMING
A0-A2
Valid Address
TAS
TCS
Valid Address
TAS
TAH
TAH
TCS
CSA#/
CSB#
TDY
TRD
TRD
IOR#
TDD
TRDV
D0-D7
Valid Data
TDD
TRDV
Valid Data
RDTm
40
áç
XR16L2750
2.25V TO 5.5V DUART WITH 64-BYTE FIFO
REV. 1.0.0
FIGURE 17. DATA BUS WRITE TIMING
A0-A2
Valid Address
Valid Address
TAS
TAS
TAH
TCS
TAH
TCS
CSA#/
CSB#
TDY
TWR
TWR
IOW#
TDH
TDS
TDS
Valid Data
D0-D7
TDH
Valid Data
16Write
FIGURE 18. RECEIVE READY & INTERRUPT TIMING [NON-FIFO MODE] FOR CHANNELS A & B
RX
INT
RXRDY#
Start
Bit
D0:D7
Stop
Bit
D0:D7
D0:D7
TSSR
TSSR
TSSR
1 Byte
in RHR
1 Byte
in RHR
1 Byte
in RHR
TSSR
TSSR
Active
Data
Ready
Active
Data
Ready
TRR
TRR
TSSR
Active
Data
Ready
TRR
IOR#
(Reading data
out of RHR)
RXNFM
41
áç
XR16L2750
2.25V TO 5.5V DUART WITH 64-BYTE FIFO
REV. 1.0.0
FIGURE 19. TRANSMIT READY & INTERRUPT TIMING [NON-FIFO MODE] FOR CHANNELS A & B
TX
Start
Bit
IER[1]
enabled
Stop
Bit
D0:D7
D0:D7
ISR is read
D0:D7
ISR is read
ISR is read
INT*
TWRI
TWRI
TWRI
TSRT
TSRT
TSRT
TXRDY#
TWT
TWT
TWT
IOW#
(Loading data
into THR)
*INT is cleared when the ISR is read or when data is loaded into the THR.
TXNonFIFO
FIGURE 20. RECEIVE READY & INTERRUPT TIMING [FIFO MODE, DMA DISABLED] FOR CHANNELS A & B
Start
Bit
RX
S D0:D7
S D0:D7 T
Stop
Bit
D0:D7
S D0:D7 T
S D0:D7 T S D0:D7 T
S D0:D7 T
RX FIFO drops
below RX
Trigger Level
TSSI
INT
FIFO
Empties
TSSR
RX FIFO fills up to RX
Trigger Level or RX Data
Timeout
RXRDY#
First Byte is
Received in
RX FIFO
TRRI
TRR
IOR#
(Reading data out
of RX FIFO)
RXINTDMA#
42
áç
XR16L2750
2.25V TO 5.5V DUART WITH 64-BYTE FIFO
REV. 1.0.0
FIGURE 21. RECEIVE READY & INTERRUPT TIMING [FIFO MODE, DMA ENABLED] FOR CHANNELS A & B
Start
Bit
RX
Stop
Bit
S D0:D7
S D0:D7 T
D0:D7
S D0:D7 T
S D0:D7 T S D0:D7 T
S D0:D7 T
RX FIFO drops
below RX
Trigger Level
TSSI
INT
RX FIFO fills up to RX
Trigger Level or RX Data
Timeout
FIFO
Empties
TSSR
RXRDY#
TRRI
TRR
IOR#
(Reading data out
of RX FIFO)
RXFIFODMA
FIGURE 22. TRANSMIT READY & INTERRUPT TIMING [FIFO MODE, DMA MODE DISABLED] FOR CHANNELS A & B
TX FIFO
Empty
TX
Start
Bit
Stop
Bit
S D0:D7 T
(Unloading)
IER[1]
enabled
Last Data Byte
Transmitted
T S D0:D7 T S D0:D7 T
S D0:D7 T S D0:D7 T
TSI
ISR is read
S D0:D7 T
ISR is read
TSRT
INT*
TX FIFO fills up
to trigger level
TXRDY#
Data in
TX FIFO
TX FIFO
Empty
TWRI
TX FIFO drops
below trigger level
TWT
IOW#
(Loading data
into FIFO)
*INT is cleared when the ISR is read or when TX FIFO fills up to the trigger level.
43
TXDMA#
áç
XR16L2750
2.25V TO 5.5V DUART WITH 64-BYTE FIFO
REV. 1.0.0
FIGURE 23. TRANSMIT READY & INTERRUPT TIMING [FIFO MODE, DMA MODE ENABLED] FOR CHANNELS A & B
Start
Bit
TX
Stop
Bit
Last Data Byte
Transmitted
S D0:D7 T S D0:D7 T
(Unloading)
IER[1]
enabled
D0:D7
S D0:D7 T
ISR Read
S D0:D7 T S D0:D7 T
S D0:D7 T
TSI
TSRT
ISR Read
INT*
TX FIFO fills up
to trigger level
TXRDY#
TX FIFO drops
below trigger level
TWRI
At least 1
empty location
in FIFO
TX FIFO
Full
TWT
IOW#
(Loading data
into FIFO)
*INT cleared when the ISR is read or when TX FIFO fills up to trigger level.
44
TXDMA
áç
XR16L2750
2.25V TO 5.5V DUART WITH 64-BYTE FIFO
REV. 1.0.0
PACKAGE DIMENSIONS (48 PIN TQFP - 7 X 7 X 1 mm)
D
D1
36
25
37
24
D1
48
13
1
2
1
B
e
A2
C
A
α
Seating
Plane
A1
L
Note: The control dimension is the millimeter column
INCHES
MILLIMETERS
SYMBOL
MIN
MAX
MIN
MAX
A
0.039
0.047
1.00
1.20
A1
0.002
0.006
0.05
0.15
A2
0.037
0.041
0.95
1.05
B
0.007
0.011
0.17
0.27
C
0.004
0.008
0.09
0.20
D
0.346
0.362
8.80
9.20
D1
0.272
0.280
6.90
7.10
e
0.020 BSC
0.50 BSC
L
0.018
0.030
0.45
0.75
α
0°
7°
0°
7°
45
D
áç
XR16L2750
2.25V TO 5.5V DUART WITH 64-BYTE FIFO
REV. 1.0.0
PACKAGE DIMENSIONS (44 PIN PLCC)
4 4 L E A D P L A S T IC L E A D E D C H IP C A R R IE R
(P L C C )
R e v. 1 .00
C
D
S e a tin g P la n e
D1
2
1
4 5° x H2
4 5° x H1
A2
44
B1
D
D1
B
D3
e
R
D3
A1
A
Note: The control dimension is the millimeter column
INCHES
MILLIMETERS
SYMBOL
MIN
MAX
MIN
MAX
A
0.165
0.180
4.19
4.57
A1
0.090
0.120
2.29
3.05
A2
0.020
---
0.51
---
B
0.013
0.021
0.33
0.53
B1
0.026
0.032
0.66
0.81
C
0.008
0.013
0.19
0.32
D
0.685
0.695
17.40
17.65
D1
0.650
0.656
16.51
16.66
D2
0.590
0.630
14.99
16.00
D3
0.500 typ.
12.70 typ.
e
0.050 BSC
1.27 BSC
H1
0.042
0.056
1.07
1.42
H2
0.042
0.048
1.07
1.22
R
0.025
0.045
0.64
1.14
46
D2
áç
XR16L2750
2.25V TO 5.5V DUART WITH 64-BYTE FIFO
REV. 1.0.0
REVISION HISTORY
DATE
REVISION
DESCRIPTION
November 2001
Rev P1.0.0
Preliminary data sheet.
March 2002
Rev P1.1.0
Corrected INTA/B pin descriptions and reset state. Clarified MCR bit-3 pin
description. Renamed Sclk to Bclk.
September 2002
Rev 1.0.0
Release into production. Clarified RTS# pin descriptions, XTAL1 pin description,
external clock description, auto RS485 half-duplex control description, EMSR
bit-3 description and updated 2.5 V, ICC and ISLEEP DC Electrical Characteristics.
NOTICE
EXAR Corporation reserves the right to make changes to the products contained in this publication in order
to improve design, performance or reliability. EXAR Corporation assumes no responsibility for the use of
any circuits described herein, conveys no license under any patent or other right, and makes no
representation that the circuits are free of patent infringement. Charts and schedules contained here in are
only for illustration purposes and may vary depending upon a user’s specific application. While the
information in this publication has been carefully checked; no responsibility, however, is assumed for
inaccuracies.
EXAR Corporation does not recommend the use of any of its products in life support applications where
the failure or malfunction of the product can reasonably be expected to cause failure of the life support
system or to significantly affect its safety or effectiveness. Products are not authorized for use in such
applications unless EXAR Corporation receives, in writing, assurances to its satisfaction that: (a) the risk of
injury or damage has been minimized; (b) the user assumes all such risks; (c) potential liability of EXAR
Corporation is adequately protected under the circumstances.
Copyright 2002 EXAR Corporation
Datasheet September 2002.
Send your UART technical inquiry with technical details to hotline: [email protected].
Reproduction, in part or whole, without the prior written consent of EXAR Corporation is prohibited.
47
áç
XR16L2750
2.25V TO 5.5V DUART WITH 64-BYTE FIFO
REV. 1.0.0
TABLE OF CONTENTS
GENERAL DESCRIPTION................................................................................................. 1
APPLICATIONS ............................................................................................................................................. 1
FEATURES .................................................................................................................................................. 1
FIGURE 1. XR16L2750 BLOCK DIAGRAM ................................................................................................................................................. 1
FIGURE 2. PIN OUT ASSIGNMENT............................................................................................................................................................. 2
ORDERING INFORMATION ............................................................................................................................. 2
PIN DESCRIPTIONS ......................................................................................................... 3
1.0 Product DESCRIPTION ........................................................................................................... 6
2.0 FUNCTIONAL DESCRIPTIONS ............................................................................................... 7
2.1 CPU INTERFACE .................................................................................................................................
2.2 5-VOLT TOLERANT INPUTS ..................................................................................................................
2.3 DEVICE RESET ....................................................................................................................................
2.4 DEVICE IDENTIFICATION AND REVISION ................................................................................................
2.5 CHANNEL A AND B SELECTION ............................................................................................................
7
7
7
7
7
FIGURE 3. XR16L2750 DATA BUS INTERCONNECTIONS ........................................................................................................................... 7
2.6 CHANNEL A AND B INTERNAL REGISTERS ............................................................................................ 8
2.7 DMA MODE ........................................................................................................................................ 8
TABLE 1: CHANNEL A AND B SELECT ....................................................................................................................................................... 8
TABLE 2: TXRDY# AND RXRDY# OUTPUTS IN FIFO AND DMA MODE .................................................................................................... 8
2.8 INTA AND INTB OUTPUTS .................................................................................................................. 9
2.9 CRYSTAL OSCILLATOR OR EXTERNAL CLOCK INPUT ............................................................................. 9
TABLE 3: INTA AND INTB PINS OPERATION FOR TRANSMITTER................................................................................................................ 9
TABLE 4: INTA AND INTB PIN OPERATION FOR RECEIVER ....................................................................................................................... 9
FIGURE 4. TYPICAL OSCILLATOR CONNECTIONS ........................................................................................................................................ 9
2.10 PROGRAMMABLE BAUD RATE GENERATOR ....................................................................................... 10
FIGURE 5. EXTERNAL CLOCK CONNECTION FOR EXTENDED DATA RATE ................................................................................................. 10
FIGURE 6. BAUD RATE GENERATOR AND PRESCALER ............................................................................................................................ 10
2.11 TRANSMITTER ................................................................................................................................. 11
2.11.1 Transmit Holding Register (THR) - Write Only ....................................................................................... 11
2.11.2 Transmitter Operation in non-FIFO Mode .............................................................................................. 11
TABLE 5: TYPICAL DATA RATES WITH A 14.7456 MHZ CRYSTAL OR EXTERNAL CLOCK .............................................................................. 11
2.11.3 Transmitter Operation in FIFO Mode ..................................................................................................... 12
2.12 RECEIVER ....................................................................................................................................... 12
FIGURE 7. TRANSMITTER OPERATION IN NON-FIFO MODE ...................................................................................................................... 12
FIGURE 8. TRANSMITTER OPERATION IN FIFO AND FLOW CONTROL MODE ............................................................................................. 12
2.12.1 Receive Holding Register (RHR) - Read-Only ....................................................................................... 13
FIGURE 9. RECEIVER OPERATION IN NON-FIFO MODE ........................................................................................................................... 13
FIGURE 10. RECEIVER OPERATION IN FIFO AND AUTO RTS FLOW CONTROL MODE ............................................................................... 13
2.13 AUTO RTS (HARDWARE) FLOW CONTROL ....................................................................................... 14
2.14 AUTO RTS HYSTERESIS ................................................................................................................. 14
2.15 AUTO CTS FLOW CONTROL ........................................................................................................... 14
FIGURE 11. AUTO RTS AND CTS FLOW CONTROL OPERATION .............................................................................................................. 15
2.16 AUTO XON/XOFF (SOFTWARE) FLOW CONTROL ............................................................................... 16
2.17 SPECIAL CHARACTER DETECT ........................................................................................................ 16
2.18 AUTO RS485 HALF-DUPLEX CONTROL ........................................................................................... 16
TABLE 6: AUTO XON/XOFF (SOFTWARE) FLOW CONTROL ....................................................................................................................... 16
2.19 INFRARED MODE ............................................................................................................................. 17
2.20 SLEEP MODE WITH AUTO WAKE-UP ............................................................................................... 17
FIGURE 12. INFRARED TRANSMIT DATA ENCODING AND RECEIVE DATA DECODING ................................................................................. 17
2.21 INTERNAL LOOPBACK ..................................................................................................................... 18
FIGURE 13. INTERNAL LOOP BACK IN CHANNEL A AND B........................................................................................................................ 18
3.0 UART INTERNAL REGISTERS ............................................................................................. 19
TABLE 7: UART CHANNEL A AND B UART INTERNAL REGISTERS .............................................................................................. 19
TABLE 8: INTERNAL REGISTERS DESCRIPTION. SHADED BITS ARE ENABLED WHEN EFR BIT-4=1 ................................................ 20
4.0 INTERNAL Register descriptions ........................................................................................ 21
I
áç
XR16L2750
2.25V TO 5.5V DUART WITH 64-BYTE FIFO
REV. 1.0.0
4.1 RECEIVE HOLDING REGISTER (RHR) - READ- ONLY ........................................................................... 21
4.2 TRANSMIT HOLDING REGISTER (THR) - WRITE-ONLY ......................................................................... 21
4.3 INTERRUPT ENABLE REGISTER (IER) - READ/WRITE ........................................................................... 21
4.3.1 IER versus Receive FIFO Interrupt Mode Operation................................................................................ 22
4.3.2 IER versus Receive/Transmit FIFO Polled Mode Operation .................................................................... 22
4.4 INTERRUPT STATUS REGISTER (ISR) - READ-ONLY ............................................................................ 23
4.4.1 Interrupt Generation: ................................................................................................................................ 23
4.4.2 Interrupt Clearing:..................................................................................................................................... 23
4.5 FIFO CONTROL REGISTER (FCR) - WRITE-ONLY ............................................................................... 24
TABLE 9: INTERRUPT SOURCE AND PRIORITY LEVEL ............................................................................................................................... 24
TABLE 10: TRANSMIT AND RECEIVE FIFO TRIGGER LEVEL SELECTION.................................................................................................... 26
4.6 LINE CONTROL REGISTER (LCR) - READ/WRITE ................................................................................. 27
4.7 MODEM CONTROL REGISTER (MCR) OR GENERAL PURPOSE OUTPUTS CONTROL - READ/WRITE ........ 28
TABLE 11: PARITY SELECTION ................................................................................................................................................................ 28
4.8 LINE STATUS REGISTER (LSR) - READ ONLY ..................................................................................... 29
4.9 MODEM STATUS REGISTER (MSR) - READ ONLY ............................................................................... 30
4.10 SCRATCH PAD REGISTER (SPR) - READ/WRITE ............................................................................... 31
4.11 ENHANCED MODE SELECT REGISTER (EMSR) ................................................................................. 31
TABLE 12: SCRATCHPAD SWAP SELECTION ............................................................................................................................................ 31
4.12 FIFO LEVEL REGISTER (FLVL) - READ-ONLY ................................................................................... 32
4.13 BAUD RATE GENERATOR REGISTERS (DLL AND DLM) - READ/WRITE ............................................... 32
4.14 DEVICE IDENTIFICATION REGISTER (DVID) - READ ONLY .................................................................. 32
TABLE 13: AUTO RTS HYSTERESIS ....................................................................................................................................................... 32
4.15 DEVICE REVISION REGISTER (DREV) - READ ONLY ......................................................................... 33
4.16 TRIGGER LEVEL REGISTER (TRG) - WRITE-ONLY ............................................................................. 33
4.17 RX/TX FIFO LEVEL COUNT REGISTER (FC) - READ-ONLY ............................................................... 33
4.18 FEATURE CONTROL REGISTER (FCTR) - READ/WRITE .................................................................... 33
TABLE 14: TRIGGER TABLE SELECT ....................................................................................................................................................... 33
4.19 ENHANCED FEATURE REGISTER (EFR) ............................................................................................ 34
TABLE 15: SOFTWARE FLOW CONTROL FUNCTIONS ............................................................................................................................... 34
4.19.1 Software Flow Control Registers (XOFF1, XOFF2, XON1, XON2) - Read/Write................................... 35
TABLE 16: UART RESET CONDITIONS FOR CHANNEL A AND B ................................................................................................... 36
ABSOLUTE MAXIMUM RATINGS...................................................................................37
TYPICAL PACKAGE THERMAL RESISTANCE DATA (MARGIN OF ERROR: ± 15%) 37
ELECTRICAL CHARACTERISTICS ................................................................................37
DC ELECTRICAL CHARACTERISTICS ...........................................................................................................37
TA=0o to 70oC (-40o to +85oC for industrial grade package), Vcc is 2.25V to 5.5V ....................................... 37
AC ELECTRICAL CHARACTERISTICS ............................................................................................................38
TA=0o to 70oC (-40o to +85oC for industrial grade package), Vcc is 2.25 to 5.5V............................................ 38
FIGURE 14. CLOCK TIMING .................................................................................................................................................................... 39
FIGURE 15. MODEM INPUT/OUTPUT TIMING FOR CHANNELS A & B......................................................................................................... 40
FIGURE 16. DATA BUS READ TIMING ..................................................................................................................................................... 40
FIGURE 17. DATA BUS WRITE TIMING .................................................................................................................................................... 41
FIGURE 18. RECEIVE READY & INTERRUPT TIMING [NON-FIFO MODE] FOR CHANNELS A & B................................................................. 41
FIGURE 19. TRANSMIT READY & INTERRUPT TIMING [NON-FIFO MODE] FOR CHANNELS A & B............................................................... 42
FIGURE 20. RECEIVE READY & INTERRUPT TIMING [FIFO MODE, DMA DISABLED] FOR CHANNELS A & B ............................................... 42
FIGURE 21. RECEIVE READY & INTERRUPT TIMING [FIFO MODE, DMA ENABLED] FOR CHANNELS A & B ................................................ 43
FIGURE 22. TRANSMIT READY & INTERRUPT TIMING [FIFO MODE, DMA MODE DISABLED] FOR CHANNELS A & B ................................... 43
FIGURE 23. TRANSMIT READY & INTERRUPT TIMING [FIFO MODE, DMA MODE ENABLED] FOR CHANNELS A & B .................................... 44
PACKAGE DIMENSIONS (48 PIN TQFP - 7 X 7 X 1 MM)..................................................................................45
PACKAGE DIMENSIONS (44 PIN PLCC).......................................................................................................46
REVISION HISTORY ....................................................................................................................................47