KODENSHI STC6075Q

STC6075Q
NPN Silicon Transistor
Descriptions
PIN Connection
• General purpose amplifier
• High voltage application
Features
• High collector breakdown voltage
: VCEO = 90V
• Low collector saturation voltage
: VCE(sat)=0.5V(MAX.)
SOT-223
Ordering Information
Type No.
Marking
STC6075Q
STC6075□
Package Code
SOT-223
□ : Year & Week Code
Absolute maximum ratings
(Ta=25°C)
Characteristic
Symbol
Ratings
Unit
Collector-Base voltage
VCBO
120
V
Collector-Emitter voltage
VCEO
90
V
Emitter-Base voltage
VEBO
6
V
IC
1.5
A(DC)
ICP*
3.0
A(Pulse)
PC
1.1
Collector current
Collector power dissipation
**
PC
W
1.5
Junction temperature
TJ
150
°C
Storage temperature
Tstg
-55~150
°C
* : Single pulse, tp= 300 ㎲
** : When mounted on ceramic substrate(250 ㎟×0.8t)
KSD-T5A006-000
1
STC6075Q
Electrical Characteristics
(Ta=25°C)
Characteristic
Symbol
Test Condition
Min. Typ. Max.
Unit
Collector-Base breakdown voltage
BVCBO
IC=100μA, IE=0
120
-
-
V
Collector-Emitter breakdown voltage
BVCEO
IC=1mA, IB=0
90
-
-
V
Emitter-Base breakdown voltage
BVEBO
IE=100μA, IC=0
6
-
-
V
Collector cut-off current
ICBO
VCB=90V, IE=0
-
-
0.1
㎂
Emitter cut-off current
IEBO
VEB=4V, IC=0
-
-
0.1
㎂
DC current gain
hFE 1)
VCE=5V, IC= 30 ㎃
200
-
400
-
Collector-Emitter saturation voltage
VCE(sat)2)
IC=500 ㎃, IB=50 ㎃
0.5
V
Base-Emitter saturation voltage
VBE(sat) 2)
IC=500 ㎃, IB=50 ㎃
-
-
1.5
V
Transition frequency
fT
VCE=5V, IC= 50 ㎃
-
170
-
㎒
Collector output capacitance
Cob
VCB=10V, IE=0, f=1 ㎒
-
10
-
㎊
* Note 1) hFE Rank : 200~400 only
* Note 2) Pulse Tester : Pulse Width ≤300μs, Duty Cycle ≤2.0%
KSD-T5A006-000
2
STC6075Q
Electrical Characteristic Curves
Fig. 1 PC - Ta
Fig. 2 IC - VBE
Fig. 3 VCE(sat) - IC
Fig. 4 IC - VCE
Fig. 5 IC - VCE
Fig. 6 hFE-IC
KSD-T5A006-000
3
STC6075Q
Electrical Characteristic Curves
Fig. 7 hFE-IC
Fig. 8 hFE-IC
Fig. 9 Cob - VCB
Fig. 10 fT - IC
℃
Fig. 11 Safe Operating Area
KSD-T5A006-000
4
STC6075Q
Outline Dimension
※ Recommend PCB solder land
KSD-T5A006-000
[Unit: mm]
5
STC6075Q
The AUK Corp. products are intended for the use as components in general electronic
equipment (Office and communication equipment, measuring equipment, home
appliance, etc.).
Please make sure that you consult with us before you use these AUK Corp. products
in equipments which require high quality and / or reliability, and in equipments which
could have major impact to the welfare of human life(atomic energy control, airplane,
spaceship, transportation, combustion control, all types of safety device, etc.). AUK
Corp. cannot accept liability to any damage which may occur in case these AUK Corp.
products were used in the mentioned equipments without prior consultation with AUK
Corp..
Specifications mentioned in this publication are subject to change without notice.
KSD-T5A006-000
6