SENSORTECHNICS AWM2300VH

AWM2000 Series
Mass flow sensor for gases
FEATURES
· Ranges 0...±30 to 0...±1000 sccm1
or 0...±4 "H2O (0...±10 mbar)
· Bidirectional sensing
· Actual mass flow sensing
· Low differential pressure sensing
SERVICE
To be used with dry gases only
The AWM series is NOT designed for liquid
flow and will be damaged by liquid flow through
the sensor
SPECIFICATIONS
ELECTRICAL CONNECTION
Maximum ratings
Supply voltage2
Power consumption
8 to 15 V
typ. 10 ±0.01 V
max. 50 mW
typ. 30 mW
Temperature limits
Operating
Storage
-25 to 85°C
-40 to 90°C
Mechanical shock
100 g (5 drops, 6 axes)
P1
P2
1 2 3 4 5 6
Note:
1
sccm denotes standard cubic centimeters per minute
2
Output voltage is ratiometric to supply voltage
June 2005 / 581
1/6
www.sensortechnics.com
AWM2000 Series
Mass flow sensor for gases
FLOW SENSOR CHARACTERISTICS3
VS = 10 ±0.01 V, TA = 25°C
Part no.
Flow range
(full scale)
Pressure
range
AWM2100V
±200 sccm
5.0 l/sec
AWM2150V
±30 sccm
5.0 l/sec
11.8 mV @ 25 sccm
5.0 l/sec
20 mV @ 2 "H2O
5.0 l/sec
50 mV @ 650 sccm
±4 "H2O
AWM2200V
AWM2300V
Output voltage
@ trim point
Max. flow change4
±1000 sccm
30 mV @ 100 sccm
PERFORMANCE CHARACTERISTICS
VS = 10 ±0.01 V, TA = 25°C
Characteristics
Zero offset
Min.
Typ.
Max.
Unit
-1.0
0
1.0
mV
Repeatability and hysteresis
AWM2300V
±1.0
(combined)
all others
±0.35
Temperature effects5
Offset
-25 to 85 °C6
Span
-25 to 25 °C
25 to 85 °C
Sensor resistance
(Pin 2 - Pin 1, Pin 6 - Pin 1)
Sensor current
(Pin 2 - Pin 1, Pin 6 - Pin 1)
Response time
Common mode pressure
% reading
±0.20
mV
AWM2100V
2.5
AWM2150V
5.0
AWM2200V
22.05
AWM2300V
5.0
AWM2100V
-2.5
AWM2150V
-5.0
AWM2200V
-22.05
AWM2300V
-5.0
% reading
5
1.0
kOhm
0.6
mA
3.0
ms
25
p si
Notes:
3
A 5 micron filter is recommended for all devices.
4
Maximum allowable rate of flow change to prevent damage.
5
Temperature shifts in differential pressure devices are mostly due to the density change of the gas over temperature.
6
Shift is relative to 25 °C.
2/6
June 2005 / 581
www.sensortechnics.com
AWM2000 Series
Mass flow sensor for gases
OUTPUT FLOW VS INTERCHANGEABILITY
VS = 10 ±0.01 V, TA = 25°C
8
7
8
OUTPUT CURVES
June 2005 / 581
3/6
www.sensortechnics.com
AWM2000 Series
Mass flow sensor for gases
HEATER CONTROL CIRCUIT
SENSING BRIDGE SUPPLY CIRCUIT
Note:
Circuits required for operation per specifications. Circuits are not on board the
sensor.
DIFFERENTIAL INSTRUMENTATION AMPLIFIER CIRCUIT (OPTIONAL)
 2 R + R1  R4 
 (V2 − V1 ) + VOffset
VO =  2
 R1  R3 
 R6 

where VOffset = VS 
+
R
R
6
5


4/6
June 2005 / 581
www.sensortechnics.com
AWM2000 Series
Mass flow sensor for gases
OUTLINE DRAWING
6.3
(0.25)
2.8
(0.11)
7.60
(0.30)
1.40
(0.055)
2.9
(0.114)
1.8
(0.07)
5.1
(0.20)
54.4
(2.14)
8.4
(0.33)
P1
P2
31.5
(1.24)
23.6
(0.93)
2.8
(0.11)
1.0
(0.04)
1 2 3 4 5 6
0.6
(0.025)
1.52
(0.06)
mass: approx. 10.8 g
2.5
(0.10)
23.9
(0.94)
30.5
(1.20)
5.1
(0.20)
4.1
(0.16)
7.3
(0.287)
12.7
(0.50)
15.5
(0.61)
dimensions in mm (inches)
Note:
Positiv flow direction is defined as proceeding from port 1 (P1) to port 2 (P2) and
results in positive output (Pin 6 > Pin 2). Negative flow direction is defined
conversely and results in negative output (Pin 6 < Pin 2).
June 2005 / 581
5/6
www.sensortechnics.com
AWM2000 Series
Mass flow sensor for gases
GAS CORRECTION FACTORS9
Gas type
Correction factor (approx.)
0.510
0.710,11
0.95
1.0
1.0
1.0
1.0
1.0
1.1
1.1
1.35
1.35
1.35
Helium (He)
Hydrogen (H2)
Argon (Ar)
Nitrogen (N2)
Oxygen (O2)
Ai r
Nitric oxide (NO)
Carbon monoxide (CO)
Methane (CH4)
Ammonia (NH3)
Nitrous oxide (N2O)
Nitrogen dioxide (NO2)
Carbon dioxide (CO2)
Notes:
9
Gas correction factors are referenced to nitrogen (N2) as calibration gas type. Approximate gas correction factors are provided
as guidelines only. Individual gas types may perform differently at temperature extremes and varying flow rates.
10
When sensing Hydrogen (H2) or Helium (He) it may be necessary to power the mass flow sensor using increased supply voltage:
Hydrogen typ. 12 V, Helium typ. 15 V
11
Hydrogen (H2) flow measurement requires the use of a special sensor. These devices provide normal operation when sensing
hydrogen flow and are designated with an "H" at the end of the order number.
ORDERING INFORMATION
Flow range
Dry gas
Hydrogen gas11
±30 sccm
AWM2150V
---
±200 sccm
AWM2100V
AWM2100VH
±1000 sccm
AWM2300V
AWM2300VH
Pressure range
Dry gas
±4 "H2O (±10 mbar)
AWM2200V