TRUMPOWER TOP100-20

T
100W SingleSeries
Output Switching
Power Supply
P LPOWER
N - 1 0SUPPLIES
0 series
TOP100
60-96 WATT
AC/DC SWITCHING
Features :
Universal AC input / Full range
Protections: Short circuit / Overload / Over voltage / Over temperature
Built-in active PFC function
IP64 design for indoor or outdoor installations
UL1310 Class 2 power unit
Cooling by free air convection
100% full load burn-in test
High reliability
Suitable for LED lighting and moving sign applications
2 years warranty
SPECIFICATION
MODEL
P/N
110
F
M
M
SELV
EQUIVALENT
LPS
( for 48V only)
PLN-100-12
PLN-100-15
PLN-100-20
PLN-100-24
TOP100-12
TOP100-15
TOP100-20
TOP100-24
12V
15V
20V
24V
CONSTANT CURRENT REGION Note.7 6 ~ 12V
7.5 ~ 15V
10 ~ 20V
12 ~ 24V
RATED CURRENT
5A
4.8A
4A
Note.6 5A
0 ~ 5A
0 ~ 4.8A
0 ~ 4A
CURRENT RANGE
Note.6 0 ~ 5A
75W
96W
96W
RATED POWER
Note.6 60W
150mVp-p
150mVp-p
150mVp-p
RIPPLE & NOISE (max.) Note.2 150mVp-p
0% ~ -15%. Can be adjusted by internal potential meter SVR1
VOLTAGE ADJ. RANGE
3% ~ -25%. Can be adjusted by internal potential meter SVR2
CURRENT ADJ. RANGE
VOLTAGE TOLERANCE Note.3 3.0%
3.0%
3.0%
3.0%
1.0%
LINE REGULATION
2.0%
LOAD REGULATION
1200ms, 80ms/230VAC 1200ms, 80ms/115VAC at full load
SETUP, RISE TIME
60ms/230VAC 30ms/115VAC at full load
HOLD UP TIME (Typ.)
DC VOLTAGE
OUTPUT
VOLTAGE RANGE
INPUT
Note.5 90 ~ 264VAC
47 ~ 63Hz
POWER FACTOR (Typ.)
PF>0.95/230VAC
EFFICIENCY (Typ.)
83%
AC CURRENT (Typ.)
INRUSH CURRENT (Typ.)
12V:0.8A/115VAC 0.4A/230VAC
COLD START 40A/230VAC
0.5mA / 240VAC
OVER CURRENT
Note.4
PROTECTION OVER VOLTAGE
OVER TEMPERATURE
WORKING TEMP.
WORKING HUMIDITY
ENVIRONMENT STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
SAFETY &
EMC
OTHERS
2.0%
PLN-100-48
TOP100-48
48V
24 ~ 48V
2A
0 ~ 2A
96W
200mVp-p
2.0%
87%
87%
15V:0.9A/115VAC
87%
0.45A/230VAC
87%
20V ~ 48V:1.1A/115VAC
Protection type : Constant current limiting, recovers automatically after fault condition is removed
13 ~ 16V
16.5 ~ 20V
22 ~ 27V
27 ~ 34V
29 ~ 36V
39 ~ 48V
87%
0.55A/230VAC
52 ~ 64V
Protection type : Shut down and latch off o/p voltage, re-power on to recover
90
10
(RTH2)
Protection type : Shut down o/p voltage, re-power on to recover
-30 ~ +50
(Refer to output load derating curve)
20 ~ 90% RH non-condensing
-40 ~ +80
0.03%/
, 10 ~ 95% RH
(0 ~ 50
)
VIBRATION
10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes
SAFETY STANDARDS
UL1310 Class 2, UL879 ( listed in UL Sign Components Manual (SAM) ), TUV EN60950-1, EN61347-1, EN61347-2-13
WITHSTAND VOLTAGE
I/P-O/P:4.25KVDC
CAN/CSA C22.2 No. 223-M91(except for 48V), IP64 approved
ISOLATION RESISTANCE
I/P-O/P:100M Ohms / 500VDC / 25 / 70% RH
EMI CONDUCTION & RADIATION Compliance to EN55015, EN55022 (CISPR22) Class B
HARMONIC CURRENT
Compliance to EN61000-3-2 Class C (>50% load) ; EN61000-3-3
Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, EN61547, EN55024, light industry level, criteria A
EMS IMMUNITY
MTBF
303.1Khrs min. MIL-HDBK-217F (25 )
DIMENSION
PACKING
NOTE
3.0%
PLN-100-36
TOP100-36
36V
18 ~ 36V
2.65A
0 ~ 2.65A
95.4W
150mVp-p
PF>0.95/115VAC at full load
85%
95 ~ 100%
PLN-100-27
TOP100-27
27V
13.5 ~ 27V
3.55A
0 ~ 3.55A
95.85W
150mVp-p
IP64
127 ~ 370VDC
FREQUENCY RANGE
LEAKAGE CURRENT
( except for 48V )
200*70.5*35mm (L*W*H)
0.52Kg; 20pcs/11.4Kg/0.76CUFT
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. Please refer to OLP characteristics.
5. Derating may be needed under low input voltage. Please check the derating curve for more details.
6. This is the maximum possible output current and power. Over load protection may be activated slightly below this level to comply with the requirement
of UL1310 class 2.
7. Constant current operation region is within 50% ~100% rated output voltage. This is the suitable operation region for LED related applications, but please
reconfirm special electrical requirements for some specific system design.
File Name:PLN-100-SPEC 2008-08-18
T
PLN-100
100W Single
Output Switching
Power AC/DC
Supply SWITCHING POWER SUPPLIES
series
TOP100
Series
60-96 WATT
Mechanical Specification
Case No.955A
Unit:mm
200
22.84
6.26
2-R2.5
+V(Red)
-V(Black)
18AWG 2C
22.84
18AWG 3C
310 10
DC OUT
AC IN
AC/L(Brown)
AC/N(Blue)
FG (Greed/Yellow)
70.5
310 10
35
6.26
Output voltage and current adjustment : remove the upper case and adjust through SVR1 & SVR2
shown in the diagram.
SVR1
SVR2
SVR1 Output voltage adjustment
SVR2 Output current adjustment
Block Diagram
Fosc : 100KHz
EMI FILTER
&
RECTIFIERS
I/P
POWER
SWITCHING
PFC
CIRCUIT
RECTIFIERS
&
FILTER
+V
-V
O.L.P.
FG
O.L.P.
PFC
CONTROL
DETECTION
CIRCUIT
PWM & PFC
CONTROL
O.V.P.
Derating Curve
Static Characteristics
Ta=25
100
100
90
80
80
70
LOAD (%)
LOAD (%)
60
40
20
-30
-15
-5
0
15
30
AMBIENT TEMPERATURE (
40
)
50 (HORIZONTAL)
60
50
40
90
100
125
135
145
155 165
175
180
200
230
264
INPUT VOLTAGE (V) 60Hz
File Name:PLN-100-SPEC 2008-08-18