AXTAL AXE10PE

Issue: 01
Specification
AXE10P(E)
Oscillator type :
PXO (Clock) with PECL Output
Parameter
min.
Frequency range
Standard frequencies
Frequency stability
Initial tolerance
vs. temperature in operating temperature
range (steady state)
vs. supply voltage variation
vs. load change
long term (aging) per year
19.440
212.5 MHz
125.000 / 155.520
MHz
-25
25 ppm
ppm
ppm
Frequency adjustment range
Electronic Frequency Control (EFC) range
RF output
Signal waveform
Load
Rise & decay time
Symmetry (duty cycle)
Start-up time
Jitter
Supply voltage VS
Current consumption (steady state @ +25°C)
Enable/disable function
Operating temperature range
Operable temperature range
Storage temperature range
Enclosure (see drawing) (LxWxH)
typ. max. Unit
±3
±1
±3
PECL
50
Date: 2005-06-08
Condition
(see Note 1)
Included in “frequency
stability”
ppm
ppm
ppm
VS ±5%
Load ±5%
per year @ +25°C
ppm
N.A.
Ω
1
ns
40
60 %
10
ms
1
ps
3.13
3.3
3.47 V
4.75
5.0
5.75 V
120 mA
80
mA
Not applicable
Pin2 = “LOW”: Enable
Pin2 = “HIGH”: Disable
0
+70 °C
-40
+85 °C
-45
+90 °C
-55
+105 °C
14.8x9.8x5.5 max
mm
To VEE
20%~80% of waveform
@ 50% of waveform
r.m.s. 10 kHz ~ 20 MHz
Option I = “33”
Option I = “50”
Option I = “33”
Option I = “50”
AXE10P
AXE10PE
Option II = “070”
Option II = “485”
IEC 61837 CO 26(AXE10P)
CO 27 (AXE10 PE)
3
gram
Weight
Tape & reel
IEC 60286-3
Packing
1500
V
HBM as in IEC 61000-4-2
ESD Sensitivity
Notes:
1. Frequency stability = initial tolerance + temp.stability
2. Absolute Pull Range (APR) = EFC range - temperature stability - supply & load change – aging
3. Terminology and test conditions are according to IEC standard IEC60679-1, unless otherwise stated
Ordering Code:
Model (Specification)
AXE10P
AXE10PE
GmbH & Co. KG
Wasemweg 5
D-74821 Mosbach
Germany
Option I Option II Frequency [MHz]
50
070
155.520
AXE10P
page 1(2)
www.axtal.com
fon: +49 (6261) 939834
fax: +49 (6261) 939836
E-mail: [email protected]
Enclosure drawing
Pin connections
AXE10P:
Pin # Symbol
Function
1
RF OUT2 Complementary RF Out
2*
N.C.
No Connection
3
GND
Ground
4
RF OUT1 RF Output
5*
N.C.
No Connection
6
Vs
Supply Voltage
* Note: Pins 2 and 5 may not be present
AXE10PE:
Pin # Symbol
1
RF OUT2
2
E/D
3
GND
4
RF OUT1
5
N.C.
6
Vs
Function
Complementary RF Out
Enable/Disable
Ground
RF Output
No Connection
Supply Voltage
Environmental conditions
Test
IEC 60068
Part ...
Visual inspection,
dimensions
Sealing tests
(if applicable)
Solderability
Resistance to
soldering heat
Shock*
IEC 60679-1
clause ...
4.3
2-17
4.6.2
2-20
2-58
4.6.3
2-27
4.6.8
Bump*
2-29
4.6.6
Free fall*
2-32
4.6.9
Test conditions
Enclosure styles as in IEC 60679-3
or 61837, if applicable
Gross leak: Test Qc,
Fine leak: Test Qk
Test Ta (235 ± 5)°C Method 1
Test Tb Method 1A, 5s
Vibration, sinusoidal* 2-6
4.6.7
Rapid change of
temperature
Dry heat
2-14
4.6.5
2-2
4.6.14
Damp heat, cyclic*
2-30
4.6.15
Cold
2-1
4.6.16
Climatic sequence*
1-7
4.6.17
Damp heat, steady
state*
Endurance tests
- ageing
- extended aging
2-3
4.6.18
Test Ea, 3 x per axes 100g, 6 ms
half-sine pulse
Test Eb, 4000 bumps per Axes, 40g,
6 ms
Test Ed procedure 1,
2 drops from 1m height
Test Fc, 30 min per axes,
10 Hz - 55 Hz 0,75mm; 55 Hz - 2
kHz, 10g
Test Na, 10 cycles at extremes of
operating temperature range
Test Ba, 16 h at upper temperature
indicated by climatic category
Test Db variant 1 severity b),
55°C/95% r.H., 6 cycles
Test Aa, 2 h at lower temperature
indicated by climatic category
Sequence of 4.6.14, 4.6.15 (1st
cycle), 4.6.16, 4.6.15 (5 cycles)
Test Ca, 56 days
4.7.1
4.7.2
30 days @ 85°C, OCXO @25°C
1000h, 2000h, 8000h @85°C
GmbH & Co. KG
Wasemweg 5
D-74821 Mosbach
Germany
AXE10P
page 2(2)
www.axtal.com
fon: +49 (6261) 939834
fax: +49 (6261) 939836
E-mail: [email protected]