ETC AMD-766

Preliminary Information
AMD-766
TM
Peripheral Bus Controller
Revision Guide
Publication # 23615
Rev: C
Issue Date: June 2001
Preliminary Information
© 2000-2001 Advanced Micro Devices, Inc. All rights reserved.
The contents of this document are provided in connection with Advanced
Micro Devices, Inc. (“AMD”) products. AMD makes no representations or
warranties with respect to the accuracy or completeness of the contents of
this publication and reserves the right to make changes to specifications and
product descriptions at any time without notice. No license, whether express,
implied, arising by estoppel or otherwise, to any intellectual property rights
is granted by this publication. Except as set forth in AMD’s Standard Terms
and Conditions of Sale, AMD assumes no liability whatsoever, and disclaims
any express or implied warranty, relating to its products including, but not
limited to, the implied warranty of merchantability, fitness for a particular
purpose, or infringement of any intellectual property right.
The AMD products described herein may contain design defects or errors
(“Product Errata”) that causes the AMD products to deviate from published
specifications. Currently characterized Product Errata may be available upon
request.
AMD’s products are not designed, intended, authorized or warranted for use
as components in systems intended for surgical implant into the body, or in
other applications intended to support or sustain life, or in any other application in which the failure of AMD’s product could create a situation where personal injury, death, or severe property or environmental damage may occur.
AMD reserves the right to discontinue or make changes to its products at any
time without notice.
Trademarks
AMD, the AMD logo, and combinations thereof, AMD Athlon, AMD-761, AMD-762, and AMD-766 are trademarks
of Advanced Micro Devices, Inc.
Microsoft is a registered trademarks of Microsoft Corporation.
Other product names used in this publication are for identification purposes only and may be trademarks of
their respective companies.
Preliminary Information
AMD-766™ Peripheral Bus Controller Revision Guide
23615C—June 2001
Revision History
Date
Rev
Description
April 2001
B
Initial public release.
June 2001
C
Added errata #22.
Preliminary Information
AMD-766™ Peripheral Bus Controller Revision Guide
23615C—June 2001
AMD-766™
Peripheral Bus Controller
Revision Guide
The purpose of the AMD-766™ Peripheral Bus Controller Revision Guide is to communicate updated
product information on the AMD-766™ peripheral bus controller to designers of computer systems and
software developers. This guide consists of four major sections:
■
Product Marking Identification: This section, which starts on page 3, provides product types,
product revisions, OPNs (Ordering Part Numbers), and product marking information.
■
Product Errata: This section, which starts on page 4, provides a detailed description of product
errata, including potential effects on system operation and suggested workarounds. An erratum is
defined as a deviation from the product’s specification. A product errata may cause the behavior of
the AMD-766 peripheral bus controller to deviate from the published specifications.
■
Revision Determination: This section starts on page 26.
■
Technical and Documentation Support: This section, which starts on page 27, provides a listing of
available technical support resources. It also lists corrections, modifications, and clarifications to
listed documents.
Revision Guide Policy
Occasionally, AMD identifies deviations from or changes to the specification of the AMD-766
peripheral bus controller. These changes are documented in the AMD-766™ Peripheral Bus Controller
Revision Guide as errata. Descriptions are written to assist system and software designers in using the
AMD-766 and corrections to AMD’s documentation on the AMD-766 peripheral bus controller are
included. This revision guide documents currently characterized product errata, but is not intended to
document all errata that may be found in the controller.
2
Preliminary Information
AMD-766™ Peripheral Bus Controller Revision Guide
23615C—June 2001
1
Product Marking Identification
Family/Core
AMD-766
Case Temperature
AMD-766™
AMD-756
AMD-766AC
AMD-756AC
B Date Code
1999
c AMD 1998
TM
C = Commercial
Temperature range
Package Type
Product Revision
Table 1.
A = Plastic Ball Grid Array
Valid Ordering Part Number Combinations
OPN
AMD-766AC
Package Type
272-pin PBGA
Operating Voltage
3.0V-3.6V
Case Temperature (max.)
85° C
Notes:
Valid combinations are configurations that are or will be supported in volume for this device. Consult the
local AMD sales office to confirm availability of specific valid combinations and to check on newly released
combinations.
3
Preliminary Information
AMD-766™ Peripheral Bus Controller Revision Guide
2
23615C—June 2001
Product Errata
This section documents AMD-766 peripheral bus controller product errata. The errata are divided into
categories to assist referencing particular errata. A unique tracking number for each erratum has been
assigned within this document for user convenience in tracking the errata within specific revision
levels. Table 2 cross-references the revisions of the controller to each erratum. An “X” indicates that
the erratum applies to the stepping. The absence of an “X” indicates that the erratum does not apply
to the stepping. Shading within the table indicates an addition or modification from the previous
release of this document.
Note:
There can be missing errata numbers. Errata that have been resolved from early revisions of the
controller have been deleted, and errata that have been reconsidered may have been deleted or
renumbered.
Table 2.
Cross-Reference of Product Revision to Errata
Revision Number
Erratum Number and Description
A0 A1 A2 B0
1 Sleep Button and Power Button are not Debounced Correctly
X
X
X
2 IDE IOR Phy Select
X
X
X
3 IDE ATA-100 Specified Data Hold Time not Met
X
X
X
4 VDD_RTC Draws Excessive Current
X
X
5 DMA Page Table not Updated for LPC Bus
X
X
X
6 DMA Terminal Count Status Register is Set Too Early
X
X
X
7 BIOS Write Lock Error
X
X
X
8 PCI Bus Parking While a Cycle is Taking Place
X
X
X
X
9 Target-Driven PCI Data Bus After PCI Turnaround Cycle
X
X
X
X
10 PCI Special Cycles Being Delayed
X
X
X
X
11 Programmable Interval Timer does not Support Unspecified Modes
X
X
X
X
12 Programmable Interval Timer does not Support Mode 1 and Mode 5
X
X
X
X
13 Programmable Interval Timer does not Accept Back-to-Back Writes to the Initial Count
Register
X
X
X
X
14 Programmable Interval Timer2 does not Load Correct Value into the Initial Count Register
X
X
X
X
15 IDE Read / Write Prefetch Hangs PCI Bus
X
X
X
X
17 EIDE Controller Bus Master Base Address Register is 256-Byte Aligned
X
X
X
X
18 USB OHCI Register Specification Differences
X
X
X
X
19 UDMA-100 Performance Does not Meet Industry-Standard Benchmarks
X
X
X
X
20 USB HccaDoneHead WriteBack Bug
X
X
X
X
21 WHQL SSID, SSVID Non-Conformance
X
X
X
X
22 Multiprocessor System May Hang While in FULL APIC Mode and IOAPIC Interrupt is Masked
4
X
Preliminary Information
AMD-766™ Peripheral Bus Controller Revision Guide
23615C—June 2001
1
Sleep Button and Power Button are not Debounced Correctly
Products Affected. A0, A1, A2
Normal Specified Operation. Whenever the sleep or power button are depressed the corresponding status
PM00, bit[SLPBTN_STS] or PM00, bit[PWRBTN_STS] should be set.
Non-conformance.The first sleep button event from a system reset sets PM00, bit[SLPBTN_STS]. After
this bit is cleared by software, the next sleep button event does not set this bit. The PM00,
[PWRBTN_STS] bit behaves in the same fashion.
Potential Effect on System. System will not go to sleep more than once when using sleep button.
Suggested Workaround. Reset the system to allow PM00 [SLPBTN_STS] and PM00 [PWRBTN_STS] to be
set.
Resolution Status. Fix planned in B0.
5
Preliminary Information
AMD-766™ Peripheral Bus Controller Revision Guide
2
23615C—June 2001
IDE IOR Phy Select
Products Affected. A0, A1, A2
Normal Specified Operation. The IDE IO cell should be connected to the 3-bit Phy select signals so that IDE
data hold times are selectable.
Non-conformance. The IDE IO cell was tied to ground instead of the 3-bit Phy select signal. This selects
the slowest mode and causes probems for UDMA operations which require fast mode. In A1 stepping a
partial fix was implemented to tie the three-bit Phy select signal to fast mode.
Potential Effect on System. UDMA modes will not operate.
Suggested Workaround. Use A1 stepping.
Resolution Status. Fix planned for B0.
6
Preliminary Information
AMD-766™ Peripheral Bus Controller Revision Guide
23615C—June 2001
3
IDE ATA-100 Specified Data Hold Time not Met
Products Affected. A0, A1, A2
Normal Specified Operation. ATA-100 Rev0.6, specifies Ultra DMA data hold time, TDVHIC, at 9ns.
Non-conformance. The hold time requirement on data from strobe for UDMA modes 0-4 was increased
from 6ns to 9ns in ATA-100 Rev0.6 specification. AMD-766 peripheral bus controller uses CLK100
cycle for all these modes which is inadequate to meet the 9ns hold time requirement.
Potential Effect on System. None detected.
Suggested Workaround. None.
Resolution Status. Fix planned for B0.
7
Preliminary Information
AMD-766™ Peripheral Bus Controller Revision Guide
4
23615C—June 2001
VDD_RTC Draws Excessive Current
Products Affected. A0, A1
Normal Specified Operation. In MOFF state the RTC circuit should consume approximately 2 micro-Amps
of current.
Non-conformance. AMD-766 peripheral bus controller consumes 2 mA of current in MOFF state which is
1000 times more than the specified current.
Potential Effect on System. 3.3VDC motherboard batteries will discharge below operating voltage. This will
result in CMOS settings not being saved.
Suggested Workaround. None.
Resolution Status. Fix planned for A2.
8
Preliminary Information
AMD-766™ Peripheral Bus Controller Revision Guide
23615C—June 2001
5
DMA Page Table not Updated for LPC Bus
Products Affected. A0, A1, A2
Normal Specified Operation. DMA page table entries need to be updated when switching between DMA
devices on LPC bus.
Non-conformance. When a DMA channel change occurs the previous DMA page table is used. Once a first
DMA transfer is completed after reset, the internal DMA page table pointer gets stuck pointing to the
initial entry.
Potential Effect on System. Cannot use two DMA devices back to back.
Suggested Workaround. None.
Resolution Status. Fix planned for B0.
9
Preliminary Information
AMD-766™ Peripheral Bus Controller Revision Guide
6
23615C—June 2001
DMA Terminal Count Status Register is Set Too Early
Products Affected. A0, A1, A2
Normal Specified Operation. The “terminal count reached” status bit should be set only when the terminal
count condition is reached.
Non-conformance. Terminal count status bit for each channel gets set one transfer count early.
Potential Effect on System. None.
Suggested Workaround. None.
Resolution Status. Fix planned for B0.
10
Preliminary Information
AMD-766™ Peripheral Bus Controller Revision Guide
23615C—June 2001
7
BIOS Write Lock Error
Products Affected. A0, A1, A2
Normal Specified Operation. When Function 0, offset 48 bit [RWR] is set to zero, writes to BIOS space
should not be allowed.
Non-conformance. When Function 0, offset 48 bit [RWR] is set to zero, writes to BIOS space should not be
allowed. However, range FFBE_FFFF:FFB0_0000 at the bottom of the 5MB BIOS space is not covered
by this bit. Also this range is not covered by any of the OAR locking registers thus this region is always
accesible when read.
Potential Effect on System. Possible BIOS security hole.
Suggested Workaround. None.
Resolution Status. Fix planned for B0.
11
Preliminary Information
AMD-766™ Peripheral Bus Controller Revision Guide
8
23615C—June 2001
PCI Bus Parking While a Cycle is Taking Place
Products Affected. A0, A1, A2, B0
Normal Specified Operation. The AMD-766 peripheral bus controller must not drive PCI C/BE# lines while
entering PCI bus park mode.
Non-conformance. If the Northbridge parks the PCI bus on the AMD-766 peripheral bus controller while
the Northbridge is executing a PCI cycle, the AMD-766 will drive the C/BE# lines for one PCI clock.
Potential Effect on System. None. The AMD Northbridge should always park on itself (default).
Suggested Workaround. None.
Resolution Status. No fix planned.
12
Preliminary Information
AMD-766™ Peripheral Bus Controller Revision Guide
23615C—June 2001
9
Target-Driven PCI Data Bus After PCI Turnaround Cycle
Products Affected. A0, A1, A2, B0
Normal Specified Operation. The target of a PCI read cycle drives the PCI data bus after the turnaround
cycle has completed. This is to limit the amount of time that the PCI address and data bus floats.
Non-conformance. When the AMD-766 peripheral bus controller is a target for a PCI read cycle, the
AMD-766 does not drive the PCI data bus until it is ready to supply the data.
Potential Effect on System. None.
Suggested Workaround. None.
Resolution Status. No fix planned.
13
Preliminary Information
AMD-766™ Peripheral Bus Controller Revision Guide
10
23615C—June 2001
PCI Special Cycles Being Delayed
Products Affected. A0, A1, A2, B0
Normal Specified Operation. Whenever a PCI special cycle is directed to the AMD-766 peripheral bus controller, the data phase can be delayed by 16 PCI clocks after assertion of FRAME# control signal.
Non-conformance. When a PCI special cycle is directed to the AMD-766 peripheral bus controller the
data phase must be valid by the third PCI clock after the assertion of FRAME# control signal. If the
PCI data is delayed longer than three PCI clocks past assertion of FRAME#, the AMD-766 peripheral
bus controller will respond improperly.
Potential Effect on System. None. The AMD-761™ system controller (Northbridge) always presents valid
data for PCI special cycle two PCI clocks after assertion of FRAME#.
Suggested Workaround. None.
Resolution Status. No fix planned.
14
Preliminary Information
AMD-766™ Peripheral Bus Controller Revision Guide
23615C—June 2001
11
Programmable Interval Timer does not Support Unspecified Modes
Products Affected. A0, A1, A2, B0
Normal Specified Operation. The Programmable Interval Timer (P.I.T.) in the AMD-766 controller only
accepts specified modes of 0 through 5 as documented in industry-standard 82C54 documentation.
Non-conformance. Some commercially available diagnostic programs such as WinCheckit98 may improperly program the timer for unspecified modes 6 or 7. Other existing Southbridge devices tolerate these
unspecified modes and default to a known mode of operation.
Potential Effect on System. If the AMD-766 controller P.I.T. is programmed to an unspecified mode such as
mode 6 or mode 7 the system will hang.
Suggested Workaround. Do not program the AMD-766 controller P.I.T. to unspecified modes.
Resolution Status. No fix planned.
15
Preliminary Information
AMD-766™ Peripheral Bus Controller Revision Guide
12
23615C—June 2001
Programmable Interval Timer does not Support Mode 1 and Mode 5
Products Affected. A0, A1, A2, B0
Normal Specified Operation. The Programmable Interval Timer (P.I.T.) in the AMD-766 controller should
accept specified modes of 0 through 5 as documented in industry-standard 82C54 documentation.
Non-conformance. The AMD-766 controller P.I.T. was designed not to support the specified external
GATE0, GATE1, and GATE2 signals. This lack of external access makes P.I.T. modes 1 and 5 unusable.
Potential Effect on System. None.
Suggested Workaround. Do not program the AMD-766 controller P.I.T. to mode 1 or mode 5.
Resolution Status. No fix planned.
16
Preliminary Information
AMD-766™ Peripheral Bus Controller Revision Guide
23615C—June 2001
13
Programmable Interval Timer does not Accept Back-to-Back Writes to the Initial
Count Register
Products Affected. A0, A1, A2, B0
Normal Specified Operation. The Programmable Interval Timer (P.I.T.) in the AMD-766 controller should
latch all writes to the initial count register CR for mode 2 as documented in industry-standard 82C54
documentation.
Non-conformance. The AMD-766 controller P.I.T. initial count register does not correctly latch a new initial count value before the previously loaded terminal count has been reached. If only the initial count
register CR is written this new value will not be latched.
Potential Effect on System. None.
Suggested Workaround. Write a complete control word to the control word register located at PORT 43h.
Then write a new initial count value "CR" for the selected counter to PORT 40h or PORT 41h or PORT
42h. This process will cause the counters to be loaded immediately with correct count values..
Resolution Status. No fix planned.
17
Preliminary Information
AMD-766™ Peripheral Bus Controller Revision Guide
14
23615C—June 2001
Programmable Interval Timer2 does not Load Correct Value into the Initial Count
Register
Products Affected. A0, A1, A2, B0
Normal Specified Operation. The Programmable Interval Timer (P.I.T.) in the AMD-766 controller should
latch all writes to the initial count register for mode 0 as documented in industry-standard 82C54 documentation.
Non-conformance. The AMD-766 controller P.I.T. TIMER2 initial count register does not correctly latch a
new initial count value when the following sequence is used:
Step 1
Disable TIMER2 by writing to PORT61[TMR2EN].
Step 2
Program TIMER2 into mode 0 and as 16-bit binary count.
Step 3
Program the initial count register CR as 0100h.
Step 4
Re-enable TIMER2 by writing to PORT61[TMR2EN].
The AMD-766 P.I.T. counter will only latch the lower 8 bits of the initial count value. For example if
CR is loaded with count 0100h then the value of FF00h is loaded into initial count register CR. This
errata only exists in TIMER2.
Potential Effect on System. None.
Suggested Workaround. None.
Resolution Status. No fix planned.
18
Preliminary Information
AMD-766™ Peripheral Bus Controller Revision Guide
23615C—June 2001
15
IDE Read / Write Prefetch Hangs PCI Bus
Products Affected. A0, A1, A2, B0
Normal Specified Operation. When IDE Read / Write prefetch is enabled and the IDE transfer mode is PIO
the AMD-766 IDE controller should transfer IDE data to the PCI bus.
Non-conformance. If an IDE transfer in UDMA mode occurs before a PIO Prefetch transfer, the PIO transfer mode disk drive data will not be transferred from the IDE bus to the PCI bus.
Potential Effect on System. The AMD-766 IDE controller causes PCI bus retry cycles to occur forever. The
system may hang or not boot to the operating system.
Suggested Workaround. Do not enable IDE Read / Write Prefetch in BIOS setup. The Current BIOS setup
default for IDE Read / Write Prefetch is disabled.
Resolution Status. No fix planned.
19
Preliminary Information
AMD-766™ Peripheral Bus Controller Revision Guide
17
23615C—June 2001
EIDE Controller Bus Master Base Address Register is 256-Byte Aligned
Products Affected. A0, A1, A2, B0
Normal Specified Operation. The IDE controller function in the AMD-766 peripheral bus controller contains a PCI configuration space offset at C1A20 "EIDE Controller Bus Master Control Registers Base
Address." These bits specify a 16-byte I/O address that maps to an EIDE register set (IBMx) that is
compliant with the SFF 8038I rev 1.0 specification "Bus Master Programming Interface for IDE ATA
Controllers."
Non-conformance. The IDE controller function in the AMD-766 peripheral bus controller has implemented a 256-byte I/O address alignment instead of the 16-byte I/O address alignment.
Potential Effect on System. None. All known software supports 16-byte and 256-byte I/O address boundaries.
Suggested Workaround. None.
Resolution Status. No fix planned.
20
Preliminary Information
AMD-766™ Peripheral Bus Controller Revision Guide
23615C—June 2001
18
USB OHCI Register Specification Differences
Products Affected. A0, A1, A2, B0
Normal Specified Operation. The USB function in the AMD-766 peripheral bus controller was designed
according to the Open Host Controller Interface Specification for USB (Open HCI), Release 1.0a.
The Open HCI specifies the following internal registers :
HcDoneHead is specified as read-only.
HcFmNumber is specified as read-only.
HFmInterval bit 30 is specified in this register as part of the FSMPS field.
HceStatus the CmdData bit is specified as read/write.
HceControl the GateA20Sequence bit is specified as read/write.
Non-conformance. The USB function in the AMD-766 peripheral bus controller has implemented the
above USB registers as follows:
HcDoneHead is implemented as read/write.
HcFmNumber is implemented as read/write.
HFmInterval bit 30 is not implemented, always returns zero.
HceStatus the CmdData bit is implemented as read-only.
HceControl the GateA20Sequence bit is implemented as read-only.
Potential Effect on System. None.
Suggested Workaround. None.
Resolution Status. No fix planned.
21
Preliminary Information
AMD-766™ Peripheral Bus Controller Revision Guide
19
23615C—June 2001
UDMA-100 Performance Does not Meet Industry-Standard Benchmarks
Products Affected. A0, A1, A2, B0
Normal Specified Operation. When the IDE controller is programmed for UDMA-100 mode, the expected
data transfer rate is 100 Mbytes per second (MBPS).
Non-conformance. If the IDE controller is programmed for UDMA-100 mode, the observed data transfer
rate is on the order of 78 MBPS.
Potential Effect on System. No functional failures occur. This errata only affects IDE UDMA-100 performance.
Suggested Workaround. None.
Resolution Status. No fix planned.
22
Preliminary Information
AMD-766™ Peripheral Bus Controller Revision Guide
23615C—June 2001
20
USB HccaDoneHead WriteBack Bug
Products Affected. A0, A1, A2, B0
Normal Specified Operation. At each start of frame a write to the HCCA memory space is initiated to
update the frame number. If a TD was retired the DoneHead pointer is also written to HCCA. Once the
DoneHead is written back, no writebacks to the DoneHead in HCCA are allowed until the DoneHead
interrupt status bit is cleared.
Non-conformance. The issue arises when an SOF writeback is pending and the DoneHead interrupt status
is cleared with additional TD retired requiring another DoneHead writeback. The list processor
updates its current writeback request transfer size to include the next DoneHead pointer, but the bus
master only accepts the size of the original request. The result is the list processor thinks the DoneHead was written back and clears the pointer, but the bus master did not complete the transfer and
the pointer is lost. Microsoft is aware of the problem and is evaluating a software patch to the driver.
Potential Effect on System. None have been observed. In the worst case, a transfer does not fully complete
if the above criteria occurs. The above criteria must occur within a one-PCLK window for this to be
observed.
Suggested Workaround. None. Most commercially available OHCI USB controller products do not implement this fix. No observations have ever occurred in validation testing or USB plugfests.
Resolution Status. No fix planned.
23
Preliminary Information
AMD-766™ Peripheral Bus Controller Revision Guide
21
23615C—June 2001
WHQL SSID, SSVID Non-Conformance
Products Affected. A0, A1, A2, B0
Normal Specified Operation. Subsystem registers in the PCI header are located at offset 2Ch–2Dh (subsystem vendor ID—SSVID), and 2Eh–2Fh (subsystem ID—SSID). PC99 requires that these registers
exist for all non-bridge function spaces. These registers are required to be read-only.
Non-conformance. The AMD-766 peripheral bus controller did not implement these registers for the nonbridge function spaces within the device (i.e. the IDE, USB, and System Management function spaces).
Potential Effect on System. Fails WHQL testing. No other system effects.
Suggested Workaround. None needed. Most commercially available Southbridge products do not
implement these registers.
Resolution Status. No fix planned.
24
Preliminary Information
AMD-766™ Peripheral Bus Controller Revision Guide
23615C—June 2001
22
Multiprocessor System May Hang While in FULL APIC Mode and IOAPIC Interrupt is
Masked
Products Affected. B0
Normal Specified Operation. The AMD-766 peripheral bus controller is designed to support FULL APIC
mode in multiprocessor systems for system management events. If an interrupt is masked in the AMD766 APIC controller then the corresponding interrupt message should not be sent to the processor via
the 3- wire APIC bus.
Non-conformance. The AMD-766 peripheral bus controller will send a interrupt message via the 3-wire
APIC bus regardless if the interrupt is masked or not.
Potential Effect on System. Since the processor had previously masked the APIC interrupt it is not
expecting to receive future APIC messages for the masked interrupt. The APIC controller will
continuously send the interrupt message via the 3-wire bus until a processor accepts the message,
causing the system to hang.
A system hang has been observed when executing a server shutdown command in Novell Netware
versions 5.0 or 5.1 while using a serial mouse. During the server shutdown sequence, software writes
an invalid CPU ID to the IOAPIC redirection table and the system does not complete the shutdown.
Note: No failure has been observed when using a PS/2 mouse.
Suggested Workaround. None.
Resolution Status. No fix planned.
25
Preliminary Information
AMD-766™ Peripheral Bus Controller Revision Guide
3
23615C—June 2001
Revision Determination
Table 3 summarizes the AMD-766™ peripheral bus controller PCI revision ID register for function 0 at
offset 8 to determine the version of silicon.
Table 3.
AMD-766™ peripheral bus controller Revision IDs
Sequence
Revision
Function 0h
Offset 8h
1
A0
01h
2
A1
01h
3
A2
01h
4
B0
02h
5
Reserved
03h
6
Reserved
04h
26
Preliminary Information
AMD-766™ Peripheral Bus Controller Revision Guide
23615C—June 2001
4
4.1
Technical and Documentation Support
Documentation Support
The following documents provide additional information regarding the operation of the AMD-766
peripheral bus controller:
■
AMD-761™ System Controller Data Sheet, order# 24088
■
AMD-762™ System Controller Data Sheet, order# 24416
■
AMD-766™ Peripheral Bus Controller Data Sheet, order# 23167
■
AMD Athlon™ System Bus Specification, order# 21902
■
AMD Athlon™ Processor BIOS, Software, and Debug Tools Developers Guide, order# 21656
■
AMD Athlon™ Processor Model 4 Data Sheet, order# 23792
■
AMD Athlon™ MP Processor Model 6 Data Sheet, order# 24685
For the latest updates, refer to www.amd.com and download the appropriate files. For documents
under NDA, please contact your local sales representative for updates.
27