SYSTEMSENSOR SSK451

Duct Smoke
Detector Accessories
Expand the versatility of the Innovair™ line of duct
smoke detectors with System Sensor notification and
test accessories.
Available Accessories
APA151
Piezo Annunciator
MHR
Mini-Horn, Red
MHW
Mini-Horn, White
PS24LO Mini-Alert Add-on Strobe (red)
PS24LOW Mini-Alert Add-on Strobe (white)
PS12/24SLENSW Wall-Mount “SMOKE” Lens
RA400Z Remote Annunciator
RTS451 Remote Test Station
RTS451KEY Remote Test Station with Key
SSK451 Multi-Signaling Accessory
These products add functionality to the duct detection system by
allowing quick, convenient inspections at eye level and effective
audible and visible notification options. All System Sensor duct
detectors and accessories are UL listed.
The APA151 piezo annunciator, which replaces the APA451 with
a new, improved look, provides an audible alarm signal, a red LED
to indicate alarm status, and a green LED to indicate power status.
It is intended for use with System Sensor 4-wire conventional duct
smoke detector applications without a system control panel, to
comply with NFPA 90A.
The MHR and MHW SpectrAlert® Advance mini-horns feature
temporal or continuous tones at high and low volume settings.
These horns are ideal for applications, where a small notification
device is desired. Their small footprint allows mounting to single
gang back boxes for aesthetically sensitive applications.
The PS24LO and PS24LOW mini alert add-on strobes can be
attached to the SSK451 multi-signaling accessory for visual alarm
signaling. The PS12/24SLENSW “SMOKE” lens is available to meet
special code requirements in certain jurisdictions.
The RA400Z remote annunciator is designed for both conventional
and intelligent applications. The red LED provides visual indication of
an alarm condition.
Agency Listings
The RTS451 and RTS451KEY remote test stations are automatic
fire detector accessories designed to test duct detectors from a more
convenient location. For 4-wire detectors, the RTS451KEY test station
features a multi-colored LED that alternates between steady green
and red. For 2-wire detectors, the LED illuminates red for alarm.
The SSK451 multi-signaling accessory is designed to work with
System Sensor 4-wire conventional duct smoke detectors. It
combines a horn feature with the key-activated test and reset
functions. Green, amber, and red LEDs indicate power, trouble, and
alarm conditions, respectively.
Specifications, Duct Smoke Detector Accessories
APA151 Piezo Annunciator
Voltage
Regulated 24 VDC
Operating Voltage
16 to 33 VDC
Maximum Alarm Current
30 mA
Temperature Range
0°C to 49°C (32°F to 120°F)
Relative Humidity
10 to 93% non-condensing
Wire Gauge
12 to 18 AWG
Dimensions
4.6 in H × 2.9 in W × .45 in D
MHR/MHW SpectrAlert® Advance Mini-Horns
Voltage
Regulated 12 DC or FWR (Full Wave Rectified)
or Regulated 24VDC or FWR
Operating Voltage
8 to 33 VDC
(9 to 33 VDC with Sync•Circuit™ Module)
Sounder Current Draw
22 mA RMS max at 8 to 17.5 Volts DC
17 mA RMS max at 8 to 17.5 Volts FWR
29 mA RMS max at 16 to 33 Volts DC
25 mA RMS max at 16 to 33 Volts FWR
Temperature Range
0°C to 49°C (32°F to 120°F)
Humidity Range
10 to 93% non-condensing
Nominal Sounder Frequency 3 kHz
Wire Gauge
12 to 18 AWG
Dimensions
4.6 in H × 2.9 in W × 0.45 in D
PS24LO/PS24LOW Mini-Alert™ Add-on Strobes
Voltage
24 VDC
Temperature Range
0°C to 49°C (32°F to 120°F)
Wire Gauge
12 to 18 AWG
Dimensions
3.8 in H × 1.6 in W × 1.6 in D
RA400Z Remote Annunciator
Voltage Range
Conventional System: 3.1 to 32 VDC
Intelligent System: 18 to 32 VDC
Maximum Alarm Current
10 mA
Dimensions
4.6 in H × 2.8 in W × 1.3 in D
RTS451 UL S4011
RA400Z UL S2522
RTS451KEY UL S2522
MHW UL S4011
RTS451 Remote Test Station
Power Requirements
Alarm LED: 2.8 to 32 VDC, 7.5 mA max.
Total Current: 105 mA max.
Test Switch
10 VA @ 32 VDC
Reset Switch
10 VA @ 32 VDC
Alarm Response Time
40 seconds max.
Temperature Range
–10°C to 60°C (14°F to 140°F)
Relative Humidity
95% non-condensing
Wire Gauge
14 to 18AWG
Dimensions
4.6 in H × 2.75 in W × 1.8 in D
RTS451KEY Remote Test Station with Key
Power Requirements
Power LED (Green): 14 to 35 VDC, 12 mA max.
Alarm LED (Red): 2.8 to 32 VDC, 7.5 mA max.
Total Current: 103 mA maximum
Alarm Response Time
40 seconds maximum
Temperature Range
–10°C to 60°C (14°F to 140°F)
Relative Humidity
95% non-condensing
Wire Gauge
14 to 18 AWG
Dimensions
4.6 in H × 2.75 in W × 1.8 in D
SSK451 Multi-signaling Accessory
Voltage
24 VDC
Power Requirements
Standby: 8 mA
Trouble: 16 mA
Alarm without strobe: 40 mA
Alarm with strobe: 65 mA
Sounder
87 dBA at ten feet
Temperature Range
–10°C to 60°C (14°F to 140°F)
Relative Humidity
95% non-condensing
Wire Gauge
14 to 22 AWG
Dimensions
4.8 in H × 4.7 in W × 1.5 in D
For the very latest product specifications and listing information, please visit
the System Sensor web site at www.systemsensor.com.
APA151 UL S4011
MHR UL S4011
3825 Ohio Avenue • St. Charles, IL 60174
Phone: 800-SENSOR2 • Fax: 630-377-6495
SSK451 UL S2522
SSK451 with PS24LOW strobe
and PS12/24 LENSW lens
©2008 System Sensor.
Product specifications subject to change without notice. Visit systemsensor.com for
current product information, including the latest version of this data sheet.
A05-0375-003 • 6/08 • #1991