ETC 601-250M-D2

TEDEA - HUNTLEIGH Model 600 Series
‘S’ Type Load Cells
Model 601 and 616 tension
compression load cells are available
in aluminum alloy (601) or stainless
steel (616).
Model 616 features stainless steel
construction, IP67 environmental
protection, 6 wire (sense) circuit,
and a unique humidity-resistant
protective coating. It is ideal for
harsh environmental, high
accuracy applications.
Ideally suited for lever conversions,
hopper/tanks and vibratory feeders
general process weighing and force
measurement applications.
·
Capacities: 50 - 100 kg (110.23 - 220.46 lbs)
·
Stainless steel (616) or aluminum (601)
·
Tension or compression applications
·
Suitable for hanging scales
·
Ideal for conversion of mechanical to electronic scales
·
Meets Handbook 44, OIML R60 and other international standards
Model 616 features aluminum alloy
construction, IP 65 environmental
protection and 4 wire circuit. It is
ideal for lower cost, high accuracy
applications.
Tedea-Huntleigh, with models
ranging from 2 to 50,000 is the
world’s largest manufacturer of
precision load cells.
[email protected] www.tedea-huntleigh.com
7800 Deering Avenue · P.O. Box 7964 · Canoga Park, CA 91309-7964 USA · Tel: 800.626.2616 · Fax: 818.340.1175
LOS ANGELES, USA DARMSTADT-EBERSTANDT, GERMANY BEIJING, CHINA CARDIFF, UK NETANYA, ISRAEL KARMIEL, ISRAEL CHARTRES, FRANCE
601 / 616 SPECIFICATIONS
GRADE
F
E
Accuracy Class
Rated Capacity
kg
100, 150, 200, 300, 500, 750, 1000
kg
mV/V
Divisions
±% of Load
Rated Output**
Total Error***
Total Error
Creep at Rated Capacity / Zero Return After 30 Minutes
1500
2 ± 0.10%
2000
0.050
0.050
0.030
0.030
Zero Balance
Temperature Range : Operating
: Compensated
Temperature Effect : On Output
: On Zero
UNITS
G*
50, 100, 250, 500
3000
0.020
0.016
10
-30 to +70
-10 to +45
0.0015
0.0030
0.0040
0.0080
Maximum Overload at the Cneter Loading Point
Ultimate Overload at the Center Loading Point
Excitation : Recommended
: Maximum
Input Impedance : 601 / 616
Output Impedance
0.0012
0.0027
±% of Load
±% of Rated Output
°C
°C
±% of Load / °C
±% of Rated Output / °C
150
300
10
% of Rated Capacity
15
415 ± 15 / 385 ± 15
Volts AC or DC
% of Rated Capacity
Volts AC or DC
Ohms
Ohms
Mega Ohms
mm
kg
350 ± 3
>1000 / >5000
<0.4
Insulation Resistance : 601 / 616
Deflection at Rated Capacity
Weight : 601 / 616
Construction : 601 / 616
Cable : 601
: 616
0.41 / 0.58
Aluminum / Stainless Steel
3 Meter, 4 Conductor, PVC Jacket, Floating Shield
3 Meter, 6 Conductor, Polyurethane Jacket, Dual Floating Shield
Environmental Protection
Approvals
IP 65 / IP 67
OIML R60
* G Class available on Model 616 > 300 kg only
** All accuracy specifications maintained when 150% of nominal load is applied for 3 mV/V output
*** Nonlinearity, hysteresis, repeatability, and output temperature effect according to OIML R60 and NIST H-44
Wiring Diagram and Dimensions
Dimensions
Model
A
B
C
D
E
F
G
601
2.75
0.80
-1.50
3.00
1.00
1.35
616
2.50
-2.04
1.57
3.15
0.75
1.08
Wiring Diagram
Model
H
I
J
K
L
M
601
Red
-Green
-Blue
Yellow
616
Green
Blue
Red
Brown
Black
White
Balanced Temperature Compression
+ In (H)
+Sense (I)
+Out (J)
- Sense (K)
- In (L)
The two “sense” wires (616 only) sample
the bridge supply voltage at the load cell.
Complete compensation of change in the
lead wire resistance, due to temperature
change and/or cable extension, is
achieved by feeding this voltage into
appropriate electronics.
- Out (M)
[email protected] www.tedea-huntleigh.com
Due to Tedea-Huntleigh’s policy of continuous
development, these specifications are subject to
change without notice.
DSU 600, 1.95
7800 Deering Avenue · P.O. Box 7964 · Canoga Park, CA 91309-7964 USA · Tel: 800.626.2616 · Fax: 818.340.1175
LOS ANGELES, USA DARMSTADT-EBERSTANDT, GERMANY BEIJING, CHINA CARDIFF, UK NETANYA, ISRAEL KARMIEL, ISRAEL CHARTRES, FRANCE