19-5488; Rev 0; 8/10 PMBus 5-Channel Power-Supply Manager and Intelligent Fan Controller The MAX34441 is a complex system monitor that can manage up to five power supplies and a fan. The power-supply manager monitors the power-supply output voltage and constantly checks for user-programmable overvoltage and undervoltage thresholds. It can also margin the powersupply output voltage up or down to a user-programmable level. The margining is performed in a closed-loop arrangement whereby the device automatically adjusts a pulse-width-modulated (PWM) output and then measures the resultant output voltage. The power-supply manager can also sequence the supplies in any order at both power-up and power-down. With the addition of an external current-sense amplifier, the device can also monitor currents. The device also contains closed-loop fan-speed control. Based on user-programmable settings for fan-control PWM duty cycles or RPM speeds at particular temperature breakpoints, the device automatically adjusts the fan speed in a manner to reduce audible noise and power consumption. Applications Network Switches/Routers Base Stations Servers Features S5 Channels of Power-Supply Management Voltage Measurement/Monitoring Differential 12-Bit 1% Accurate ADC Min/Max Threshold Excursion Detection Supports Current Monitoring with External Current-Sense Amplifier Automatic Closed-Loop Margining Programmable Up and Down Sequencing Power-Good Output S1 Channel of Fan Control Supports 3-Wire and 4-Wire Fans Automatic Closed-Loop Fan-Speed Control Support for Dual Tachometer Fans Fan-Fault Detection SSupports Up to Six Temperature Sensors External Thermal Diode Interface with Automatic Series Resistance Cancellation One Internal Temperature Sensor Support for Up to Four Additional I2C Digital Temp Sensor ICs Fault Detection on All Temp Sensors SPMBus™-Compliant Command Interface SI2C/SMBus™-Compatible Serial Bus with Bus Timeout Function Smart Grid Network Systems SOn-Board Nonvolatile Fault Logging and Default Configuration Setting Industrial Controls SNo External Clocking Required S+3.3V Supply Voltage Ordering Information TEMP RANGE PIN-PACKAGE MAX34441ETL+ PART -40NC to +85NC 40 TQFN-EP* MAX34441ETL+T -40NC to +85NC 40 TQFN-EP* +Denotes a lead(Pb)-free/RoHS-compliant package. T = Tape and reel. *EP = Exposed pad. PMBus is a trademark of SMIF, Inc. SMBus is a trademark of Intel Corp. Note: Some revisions of this device may incorporate deviations from published specifications known as errata. Multiple revisions of any device may be simultaneously available through various sales channels. For information about device errata, go to: www.maxim-ic.com/errata. ________________________________________________________________ Maxim Integrated Products 1 For pricing, delivery, and ordering information, please contact Maxim Direct at 1-888-629-4642, or visit Maxim’s website at www.maxim-ic.com. MAX34441 General Description MAX34441 PMBus 5-Channel Power-Supply Manager and Intelligent Fan Controller TABLE OF CONTENTS Absolute Maximum Ratings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 Recommended Operating Conditions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 DC Electrical Characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 Electrical Specifications: I2C/SMBus Interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 I2C/SMBus Timing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 Typical Operating Characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 Pin Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 Pin Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 Block Diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 Multiple Device Connection Diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13 Detailed Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14 Address Select . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16 SMBus/PMBus Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16 SMBus/PMBus Communication Examples . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16 Group Command . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17 Group Command Write Format . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17 Addressing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17 ALERT and Alert Response Address (ARA) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17 Alert Response Address (ARA) Byte Format . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18 Host Sends or Reads Too Few Bits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18 Host Sends or Reads Too Few Bytes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18 Host Sends Too Many Bytes or Bits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18 Host Reads Too Many Bytes or Bits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18 Host Sends Improperly Set Read Bit in the Slave Address Byte . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18 Unsupported Command Code Received . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18 Invalid Data Received . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18 Host Reads from a Write-Only Command . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19 Host Writes to a Read-Only Command . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19 SMBus Timeout . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19 PMBus Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19 PMBus Protocol Support . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19 Data Format . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19 Interpreting Received DIRECT Format Values . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20 Sending a DIRECT Format Value . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20 Fault Management and Reporting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21 System Watchdog Timer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22 Temperature Sensor Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22 2 PMBus 5-Channel Power-Supply Manager and Intelligent Fan Controller Fan Control Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22 Dual Fan Applications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22 Automatic Fan Control Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22 Pulse Stretching . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24 Fan Spin-Up . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25 PMBus Commands . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26 PAGE (00h) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26 OPERATION (01h) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27 ON_OFF_CONFIG (02h) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28 CLEAR_FAULTS (03h) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28 WRITE_PROTECT (10h) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28 STORE_DEFAULT_ALL (11h) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29 RESTORE_DEFAULT_ALL (12h) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29 CAPABILITY (19h) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29 VOUT_MODE (20h) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29 VOUT_MARGIN_HIGH (25h) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29 VOUT_MARGIN_LOW (26h) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30 VOUT_SCALE_MONITOR (2Ah) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30 IOUT_CAL_GAIN (38h) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30 FAN_CONFIG_1_2 (3Ah) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31 FAN_COMMAND_1 (3Bh) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31 VOUT_OV_FAULT_LIMIT (40h) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32 VOUT_OV_WARN_LIMIT (42h) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32 VOUT_UV_WARN_LIMIT (43h) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32 VOUT_UV_FAULT_LIMIT (44h) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32 IOUT_OC_WARN_LIMIT (46h) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33 IOUT_OC_FAULT_LIMIT (4Ah) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33 OT_FAULT_LIMIT (4Fh) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33 OT_WARN_LIMIT (51h) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34 POWER_GOOD_ON (5Eh) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34 POWER_GOOD_OFF (5Fh) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34 TON_DELAY (60h) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35 TON_MAX_FAULT_LIMIT (62h) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35 TOFF_DELAY (64h) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35 STATUS_BYTE (78h) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35 STATUS_WORD (79h) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36 STATUS_VOUT (7Ah) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36 STATUS_CML (7Eh) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36 3 MAX34441 TABLE OF CONTENTS (continued) MAX34441 PMBus 5-Channel Power-Supply Manager and Intelligent Fan Controller TABLE OF CONTENTS (continued) STATUS_MFR_SPECIFIC (80h) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37 STATUS_FANS_1_2 (81h) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37 READ_VOUT (8Bh) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37 READ_IOUT (8Ch) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37 READ_TEMPERATURE_1 (8Dh) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37 READ_FAN_SPEED_1 (90h) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38 PMBUS_REVISION (98h) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38 MFR_ID (99h) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38 MFR_MODEL (9Ah) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38 MFR_REVISION (9Bh) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38 MFR_LOCATION (9Ch) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38 MFR_DATE (9Dh) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38 MFR_SERIAL (9Eh) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38 MFR_MODE (D1h) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39 MFR_VOUT_PEAK (D4h) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40 MFR_IOUT_PEAK (D5h) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40 MFR_TEMPERATURE_PEAK (D6h) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40 MFR_VOUT_MIN (D7h) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40 MFR_FAULT_RESPONSE (D9h) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40 MFR_FAULT_RETRY (DAh) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41 MFR_NV_FAULT_LOG (DCh) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41 MFR_TIME_COUNT (DDh) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 44 MFR_MARGIN_CONFIG (E0h) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 44 MFR_TEMP_SENSOR_CONFIG (F0h) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45 MFR_FAN_CONFIG (F1h) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46 MFR_FAN_LUT (F2h) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 48 TEMPERATURE STEP: Temperature Level Setting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 48 FAN SPEED STEP: Fan PWM Duty Cycle or Fan Speed Setting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 49 MFR_READ_FAN_PWM (F3h) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50 MFR_FAN_FAULT_LIMIT (F5h) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50 MFR_FAN_WARN_LIMIT (F6h) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50 Applications Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 51 Power-Supply Decoupling . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 51 Open-Drain Pins . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 51 Typical Operating Circuit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 52 Package Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 52 Revision History . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 53 4 PMBus 5-Channel Power-Supply Manager and Intelligent Fan Controller Figure Figure Figure Figure Figure Figure 1. Automatic Fan Control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2. Fan Speed Example . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3. Fan Spin-Up . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4. Power-Supply Sequencing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5. MFR_NV_FAULT_LOG . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6. Fan Lookup Table (LUT) Format . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23 24 25 34 42 49 LIST OF TABLES Table Table Table Table Table Table Table Table Table Table Table Table Table Table Table Table Table Table Table Table Table Table Table Table Table Table Table Table Table Table Table Table Table Table Table 1. PMBus Command Codes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2. PMBus/SMBus Serial-Port Address . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3. PMBus Command Code Coefficients . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4. Coefficients for DIRECT Format Value . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5. Device Parametric Monitoring States . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6. DS75LV Address Pin Configurations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7. Fan Control Operation Modes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8. Page Commands . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9. OPERATION Command Byte (When Bit 3 of ON_OFF_CONFIG = 1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10. OPERATION Command Byte (When Bit 3 of ON_OFF_CONFIG = 0) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11. ON_OFF_CONFIG (02h) Command Byte . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12. WRITE_PROTECT Command Byte . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13. CAPABILITY Command Byte . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14. VOUT_SCALE_MONITOR . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15. FAN_CONFIG_1_2 Command Byte . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16. PWM Fan Mode (FAN_CONFIG_1_2 Bit 6 = 0) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17. RPM Fan Mode (FAN_CONFIG_1_2 Bit 6 = 1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18. IOUT_OC_FAULT_LIMIT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19. TON_MAX_FAULT_LIMIT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20. STATUS_BYTE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21. STATUS_WORD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22. STATUS_VOUT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23. STATUS_CML . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24. STATUS_MFR_SPECIFIC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25. STATUS_FANS_1_2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26. MFR_MODE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27. MFR_FAULT_RESPONSE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28. MFR_FAULT_RESPONSE Codes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29. MFR_NV_FAULT_LOG . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30. MFR_MARGIN_CONFIG . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31. MFR_TEMP_SENSOR_CONFIG . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32. MFR_FAN_CONFIG . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33. MFR_FAN_LUT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34. Valid Temperature Range . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35. Monitored Fan Fault and Warning Parameters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14 16 20 21 21 22 23 26 27 27 28 28 29 30 31 31 31 33 35 35 36 36 36 37 37 39 40 41 42 44 45 46 48 48 50 5 MAX34441 LIST OF FIGURES MAX34441 PMBus 5-Channel Power-Supply Manager and Intelligent Fan Controller ABSOLUTE MAXIMUM RATINGS VDD to VSS............................................................-0.3V to +5.5V RS- to VSS.............................................................-0.3V to +0.3V All Other Pins Except REG18 and REG25 Relative to VSS......................... -0.3V to (VDD + 0.3V)* Continuous Power Dissipation (TA = +70NC) 40-Pin TQFN (derate 35.7mW/NC above +70NC)..........................2857.1mW Operating Temperature Range........................... -40NC to +85NC Storage Temperature Range............................. -55NC to +125NC Lead Temperature (soldering, 10s).................................+260NC Soldering Temperature (reflow).......................................+260NC *Subject to not exceeding +5.5V. Stresses beyond those listed under “Absolute Maximum Ratings” may cause permanent damage to the device. These are stress ratings only, and functional operation of the device at these or any other conditions beyond those indicated in the operational sections of the specifications is not implied. Exposure to absolute maximum rating conditions for extended periods may affect device reliability. RECOMMENDED OPERATING CONDITIONS (TA = -40NC to +85NC.) PARAMETER SYMBOL MAX UNITS 2.7 5.5 V VIH 0.7 x VDD VDD + 0.3 V VIL -0.3 0.3 x VDD V VDD Operating Voltage Range VDD Input Logic 1 Input Logic 0 CONDITIONS (Note 1) MIN TYP Input Logic-High: SCL, SDA, MSCL, MSDA VI2C_IH 2.7V P VDD P 3.6V (Note 1) 2.1 VDD + 0.3 V Input Logic-Low: SCL, SDA, MSCL, MSDA VI2C_IL 2.7V P VDD P 3.6V (Note 1) -0.3 +0.8 V DC ELECTRICAL CHARACTERISTICS (VDD = 2.7V to 5.5V, TA = -40NC to +85NC, unless otherwise noted. Typical values are at VDD = 3.3V, TA = +25NC, unless otherwise noted.) PARAMETER Supply Current Brownout Voltage SYMBOL ICPU CONDITIONS Brownout Hysteresis VBOH Monitors VDD (Note 1) Internal System Clock fMOSC Output Logic-Low Output Logic-High PWM, PSEN Pullup Current VOL1 VOH1 IPU 2.40 ADC Internal Reference Temperature Drift 6 2.46 2.55 30 mV MHz -3 +2 -6.5 +1.6 VPIN = VSS, VDD = 3.3V 0.4 VDD 0.5 38 % V V 55 107 FA -1 +1 % -0.5 +0.5 % 1.225 VERR V 4.0 -40NC P TA P +25NC IOL = 4mA (Note 1) IOH = -2mA (Note 1) UNITS mA +25NC P TA P +85NC ADC Internal Reference ADC Voltage Measurement Error MAX 8 Monitors VDD (Note 1) fERR:MOSC TYP 2.5 IPROGRAM VBO System Clock Error (Note 3) MIN (Note 2) V PMBus 5-Channel Power-Supply Manager and Intelligent Fan Controller (VDD = 2.7V to 5.5V, TA = -40NC to +85NC, unless otherwise noted. Typical values are at VDD = 3.3V, TA = +25NC, unless otherwise noted.) PARAMETER SYMBOL CONDITIONS ADC Internal Reference Initial Accuracy (+25NC) VFS ADC Measurement Resolution VLSB 1.213 1.225 MAX UNITS +1 mV 1.237 300 ADC Bit Resolution RIN ADC Integral Nonlinearity INL Bits 15 MI DNL VOFFSET Internal Temperature Measurement Error Remote Temperature Measurement Error (MAX34441 Error Only) Q4 LSB Q1 LSB LSB Q2 -3 +3 TA = 0NC to +60NC, TDIODE = +60NC to +120NC -1.5 +1.5 TA = 0NC to +60NC, TDIODE = -45NC to +120NC -1.75 +1.75 TA = -40NC to +85NC, TDIODE = +60NC to +120NC -2.75 +2.75 TA = -40NC to +85NC, TDIODE = -45NC to +120NC -3.0 +3.0 TA = -40NC to +85NC V FV 12 RS+ Input Resistance ADC Offset TYP -1 ADC Full-Scale Input Voltage ADC Differential Nonlinearity MIN NC NC Store Default All Time 37 ms Nonvolatile Log Write Time 12 ms Nonvolatile Log Delete Time 200 ms Flash Endurance Data Retention NFLASH TA = +50NC 20,000 TA = +50NC 100 Voltage Sample Rate Write Cycles Years 5 ms Current Sample Rate 200 ms RPM Sample Rate 1000 ms Temperature Sample Rate 1000 ms 12 ms Device Startup Time PWM Frequency PWM Resolution Measured from POR until monitoring begins Power supply Fan 62.5 30 kHz 25,000 Power supply 6 Fan 7 Hz Bits 7 MAX34441 DC ELECTRICAL CHARACTERISTICS (continued) MAX34441 PMBus 5-Channel Power-Supply Manager and Intelligent Fan Controller I2C/SMBus INTERFACE ELECTRICAL SPECIFICATIONS (VDD = 2.7V to 5.5V, TA = -40NC to +85NC, unless otherwise noted. Typical values are at VDD = 3.3V, TA = +25NC, unless otherwise noted.) PARAMETER SYMBOL CONDITIONS MIN TYP MAX UNITS 100 kHz SCL Clock Frequency fSCL 10 Bus Free Time Between STOP and START Conditions tBUF 4.7 Fs Hold Time (Repeated) START Condition tHD:STA 4.0 Fs Low Period of SCL tLOW 4.7 Fs High Period of SCL tHIGH 4.0 Fs Receive 0 Transmit 300 Data Hold Time tHD:DAT Data Setup Time tSU:DAT 100 START Setup Time tSU:STA 4.7 SDA and SCL Rise Time ns ns Fs tR SDA and SCL Fall Time tF STOP Setup Time Clock Low Timeout tSU:STO 4.0 tTO 25 300 ns 300 ns 35 ms Fs Note 1: All voltages are referenced to ground (VSS). Currents entering the IC are specified as positive, and currents exiting the IC are negative. Note 2: This does not include pin input/output currents. Note 3: Guaranteed by design. I2C/SMBus Timing SDA tBUF tF tLOW tHD:STA tSP SCL tHD:STA tHIGH tR tHD:DAT STOP START NOTE: TIMING IS REFERENCED TO VIL(MAX) AND VIH(MIN). 8 tSU:STA tSU:DAT REPEATED START tSU:STO PMBus 5-Channel Power-Supply Manager and Intelligent Fan Controller (TA = +25°C, unless otherwise noted.) SUPPLY CURRENT vs. SUPPLY VOLTAGE SUPPLY CURRENT vs. TEMPERATURE 2.6 2.6 2.5 2.4 IDD (mA) 2.5 IDD (mA) MAX34441 toc02 2.7 MAX34441 toc01 2.7 VDD = 3.3V 2.3 2.4 TA = +25°C 2.3 2.2 2.2 2.1 2.1 2.0 2.0 -40 -20 0 20 40 60 80 2.7 100 3.1 3.5 3.9 4.3 4.7 5.1 5.5 TEMPERATURE (°C) VDD (V) WEAK PULLUP VOLTAGE vs. TIME AT POR (UNLOADED PINS, VDD = 3.3V) IDD vs. TIME DURING A FLASH WRITE (TA = +25°C, VDD = 3.3V) MAX34441 toc04 MAX34441 toc03 C1 = PSEN0 0V C3 = PWM0 0V 1mA/div 1V/div C2 = VDD 0V 0A 2ms/div 1ms/div FILTERED MARGINING VOLTAGE vs. TIME DURING MARGIN UP MAX34441 toc05 200mV/div 0V 100ms/div 9 MAX34441 Typical Operating Characteristics PMBus 5-Channel Power-Supply Manager and Intelligent Fan Controller VSS REG18 PSEN3 PWM2 PWM1 PSEN2 PSEN1 PWM0 TOP VIEW REG25 PSEN0 MAX34441 Pin Configuration 30 29 28 27 26 25 24 23 22 21 SDA 31 20 PWM3 SCL 32 19 PSEN4 A0/MUXSEL 33 18 PWM4 FAULT 34 17 TACH5 CONTROL 35 16 PWM5 MAX34441 VSS 36 15 MSCL A1/PG/TACHSEL 37 14 MSDA ALERT 38 RS-5 39 13 RST EP + 12 RS-2 11 RS+2 7 8 9 10 VDD RS-1 6 RS-0 RS+4 5 RS+1 VSS 4 RS+0 3 RS-3 2 RS+3 1 RS-4 RS+5 40 TQFN (6mm × 6mm × 0.75mm) Pin Description 10 PIN NAME FUNCTION 1 RS-4 Ground Reference for ADC4 Voltage Measurement 2, 21, 36 VSS Digital-Supply Return Node (Ground) 3 RS+4 Power-Supply ADC Voltage-Sense Input, Measurement Relative to RS-4 4 RS-3 Ground Reference for ADC3 Voltage Measurement 5 RS+3 Power-Supply ADC Voltage-Sense Input, Measurement Relative to RS-3 6 RS+0 Power-Supply ADC Voltage-Sense Input, Measurement Relative to RS-0 7 RS-0 Ground Reference for ADC0 Voltage Measurement 8 RS+1 Power-Supply ADC Voltage-Sense Input, Measurement Relative to RS-1 9 VDD Supply Voltage. Bypass VDD to VSS with a 0.1FF capacitor. 10 RS-1 Ground Reference for ADC1 Voltage Measurement 11 RS+2 Power-Supply ADC Voltage-Sense Input, Measurement Relative to RS-2 12 RS-2 Ground Reference for ADC2 Voltage Measurement 13 Reset Active-Low Input 14 RST MSDA 15 MSCL Master I2C Clock Output. Open-drain output. 16 PWM5 Fan PWM Output #5. CMOS push-pull output. Low when the fan is disabled. A 100% duty cycle implies this pin is continuously high. 17 TACH5 Fan Tachometer Input 18 PWM4 PWM Margin Output #4. High impedance when the margining is disabled. A 100% duty cycle implies this pin is continuously high. 19 PSEN4 Power-Supply Enable Output #4. Programmable through MFR_MODE for either active high or active low and either open drain or CMOS push-pull. Master I2C Data Input/Output. Open-drain output. PMBus 5-Channel Power-Supply Manager and Intelligent Fan Controller PIN NAME FUNCTION 20 PWM3 PWM Margin Output #3. High impedance when the margining is disabled. A 100% duty cycle implies this pin is continuously high. 22 REG18 Regulator for Low-Voltage Digital Circuitry. Bypass REG18 to VSS with 1FF and 10nF capacitors. Do not connect other circuitry to this pin. 23 PSEN3 Power-Supply Enable Output #3. Programmable through MFR_MODE for either active high or active low and either open drain or CMOS push-pull. 24 PWM2 PWM Margin Output #2. High impedance when the margining is disabled. A 100% duty cycle implies this pin is continuously high. 25 PSEN2 Power-Supply Enable Output #2. Programmable through MFR_MODE for either active high or active low and either open drain or CMOS push-pull. 26 PWM1 PWM Margin Output #1. High impedance when the margining is disabled. A 100% duty cycle implies this pin is continuously high. 27 PSEN1 Power-Supply Enable Output #1. Programmable through MFR_MODE for either active high or active low and either open drain or CMOS push-pull. 28 PWM0 PWM Margin Output #0. High impedance when the margining is disabled. A 100% duty cycle implies this pin is continuously high. 29 REG25 Regulator for Analog Circuitry. Bypass REG25 to VSS with 1FF and 10nF capacitors. Do not connect other circuitry to this pin. 30 PSEN0 Power-Supply Enable Output #0. Programmable through MFR_MODE for either active high or active low and either open drain or CMOS push-pull. 31 SDA I2C/SMBus-Compatible Input/Output 32 SCL I2C/SMBus-Compatible Clock Input 33 SMBus Address 0 Input/Multiplexer Control Output. This dual-function pin is sampled on device power-up to determine the SMBus address; connect a 100kI resistor from this pin to either VSS or A0/MUXSEL VDD to set the address. After device power-up, this pin becomes an output that acts as voltage/ current selector for an external analog multiplexer. MUXSEL is low for voltage measurements and high for current measurements. 34 FAULT Active-Low, Open-Drain Fault Input/Output. This pin is asserted when one or more of the power supplies in a global group are shut down due to a fault condition. Also, this pin is monitored and, when it is asserted, all power supplies in a global group are shut down. This pin is used to provide hardware control for power supplies in a global group across multiple devices. This output is unconditionally deasserted when RST is asserted or the device is power cycled. This pin has a 50Fs deglitch filter. 35 CONTROL Device Enable. Option through ON_OFF_CONFIG for active-low or active-high power-supply control. This pin has a 50Fs deglitch filter. A1/PG/ TACHSEL SMBus Address 1 Input/Power-Good Output. This triple-function pin is sampled on device powerup to determine the SMBus address; connect a 100kI resistor from this pin to either VSS or VDD to set the address. After device power-up, this pin becomes an output that transitions high when all the enabled power supplies are above their associated POWER_GOOD_ON thresholds. Alternately, this pin can be programmed through MFR_MODE to select between two tachometers in dual-fan applications. 37 38 Active-Low, Open-Drain Alert Output 39 ALERT RS-5 40 RS+5 Thermal Diode ADC Voltage Positive-Sense Input, Measurement Relative to RS-5 — EP Thermal Diode ADC Voltage Negative-Sense Input, Measurement Relative to RS+5 Exposed Pad (Bottom Side of Package). Connect EP to VSS. Note: All pins except VDD, VSS, REG18, REG25, ADC, and the EP are high impedance with a 50µA pullup during device power-up and reset. After device reset, the weak pullup is removed, and the pin is configured as input or output. 11 MAX34441 Pin Description (continued) PMBus 5-Channel Power-Supply Manager and Intelligent Fan Controller MAX34441 Block Diagram VDD VSS REG25 VSS REG18 VSS POWER CONTROL PULSEWIDTH MODULATOR 2.5V VREG 1.8V VREG PWM0 PWM1 PWM2 PWM3 PWM4 PWM5 PSEN0 4MHz OSCILLATOR MSCL SDA SCL RST ALERT FAULT CONTROL A0/MUXSEL A1/PG/TACHSEL SMBus MASTER INTERFACE ADC SYSTEM CONTROL SIGNALS MAX34441 12 FAN TACHOMETER INPUT SMBus SLAVE INTERFACE RAM FLASH PSEN1 PSEN2 PSEN3 PSEN4 MUX MSDA 16-BIT MAXQ RISC CORE POWERSUPPLY OUTPUT ENABLES TEMP SENSOR TACH5 RS+0 RS-0 RS+1 RS-1 RS+2 RS-2 RS+3 RS-3 RS+4 RS-4 RS+5 RS-5 PMBus 5-Channel Power-Supply Manager and Intelligent Fan Controller +3.3V ALERT HOST INTERFACE CLOCK DATA CONTROL RST SDA SCL RST ALERT MAX34441 #0 FAULT CONTROL A1/PG/TACHSEL A0/MUXSEL +3.3V SDA SCL RST ALERT FAULT MAX34441 #1 CONTROL A1/PG/TACHSEL A0/MUXSEL ADDITIONAL DEVICES 13 MAX34441 Multiple Device Connection Diagram MAX34441 PMBus 5-Channel Power-Supply Manager and Intelligent Fan Controller Detailed Description The MAX34441 is a highly integrated system monitor based upon a 4MHz, 16-bit, MAXQM microcontroller with factory-programmed functionality to monitor up to five power supplies and a system cooling fan. The device provides power-supply closed-loop control, fan-speed monitoring, and local/remote thermal-sensing facilities. The power-supply manager monitors the power-supply output voltage and constantly checks for user-programmable overvoltage and undervoltage thresholds. It also can margin the power-supply output voltage up or down by a user-programmable level. The margining is performed in a closed-loop arrangement, whereby the device automatically adjusts a pulse-width-modulated (PWM) output and then measures the resultant output voltage. The power-supply manager can also sequence the supplies in any order at both power-up and powerdown. With the addition of an external current-sense amplifier, the device can also monitor currents. Thermal monitoring can be accomplished using up to six temperature sensors, including an on-chip thermal sensor, four DS75LV digital thermometers, and a remote thermal diode. Temperature offset can be added to individual sensors to compensate for thermal differences in a system. Communication with the DS75LV temperature sensor is conducted through a dedicated I2C/SMBus interface. The device also contains closed-loop fan-speed control. Based on user-programmable settings for fan-control PWM duty cycles or for fan RPM speeds at particular temperature breakpoints, the device automatically adjusts the fan speed in a manner to reduce audible noise and power consumption. The device provides ALERT and FAULT output signals. Host communications are conducted through a PMBuscompatible communications port. Address input connections are also provided to allow up to four MAX34441 devices to reside on the system’s I/O bus. Table 1. PMBus Command Codes CODE 00h 01h 02h 03h 10h 11h 12h 19h 20h 25h 26h 2Ah 38h 3Ah 3Bh 40h 42h 43h 44h 46h 4Ah 4Fh COMMAND NAME PAGE OPERATION ON_OFF_CONFIG CLEAR_FAULTS WRITE_PROTECT STORE_DEFAULT_ALL RESTORE_DEFAULT_ALL CAPABILITY VOUT_MODE VOUT_MARGIN_HIGH VOUT_MARGIN_LOW VOUT_SCALE_MONITOR IOUT_CAL_GAIN FAN_CONFIG_1_2 FAN_COMMAND_1 VOUT_OV_FAULT_LIMIT VOUT_OV_WARN_LIMIT VOUT_UV_WARN_LIMIT VOUT_UV_FAULT_LIMIT IOUT_OC_WARN_LIMIT IOUT_OC_FAULT_LIMIT OT_FAULT_LIMIT TYPE PAGE 0–4 R/W Byte R/W Byte R/W Byte Send Byte R/W Byte Send Byte Send Byte Read Byte Read Byte R/W Word R/W Word R/W Word R/W Word R/W Byte R/W Word R/W Word R/W Word R/W Word R/W Word R/W Word R/W Word R/W Word R/W R/W R/W W R/W W W R R R/W R/W R/W R/W — — R/W R/W R/W R/W R/W R/W — MAXQ is a registered trademark of Maxim Integrated Products, Inc. 14 PAGE 5 PAGE 6–11 (NOTE R/W — R/W W R/W W W R R — — — — R/W R/W — — — — — — — 1) R/W — R/W W R/W W W R R — — — — — — — — — — — — R/W PAGE 255 R/W W R/W W R/W W W R R — — — — — — — — — — — — — NO. OF BYTES FLASH STORED (NOTE 2) DEFAULT VALUE (NOTE 2) 1 1 1 0 1 0 0 1 1 2 2 2 2 1 2 2 2 2 2 2 2 2 N N Y N N N N N FIXED Y Y Y Y Y Y Y Y Y Y Y Y Y 00h 00h 1Ah — 00h — — 00h/10h 40h 0000h 0000h 7FFFh 0000h 00h FFFFh 7FFFh 7FFFh 0000h 0000h 7FFFh 0000h 7FFFh PMBus 5-Channel Power-Supply Manager and Intelligent Fan Controller CODE COMMAND NAME TYPE PAGE 0–4 51h 5Eh 5Fh 60h 62h 64h 78h 79h 7Ah 7Eh 80h 81h 8Bh 8Ch 8Dh 90h 98h 99h 9Ah 9Bh 9Ch 9Dh 9Eh D1h D4h D5h D6h D7h D9h DAh DCh DDh E0h F0h F1h F2h F3h F5h F6h OT_WARN_LIMIT POWER_GOOD_ON POWER_GOOD_OFF TON_DELAY TON_MAX_FAULT_LIMIT TOFF_DELAY STATUS_BYTE STATUS_WORD STATUS_VOUT STATUS_CML STATUS_MFR_SPECIFIC STATUS_FANS_1_2 READ_VOUT READ_IOUT READ_TEMPERATURE_1 READ_FAN_SPEED_1 PMBUS_REVISION MFR_ID MFR_MODEL MFR_REVISION MFR_LOCATION MFR_DATE MFR_SERIAL MFR_MODE MFR_VOUT_PEAK MFR_IOUT_PEAK MFR_TEMPERATURE_PEAK MFR_VOUT_MIN MFR_FAULT_RESPONSE MFR_FAULT_RETRY MFR_NV_FAULT_LOG MFR_TIME_COUNT MFR_MARGIN_CONFIG MFR_TEMP_SENSOR_CONFIG MFR_FAN_CONFIG MFR_FAN_LUT MFR_READ_FAN_PWM MFR_FAN_FAULT_LIMIT MFR_FAN_WARN_LIMIT R/W Word R/W Word R/W Word R/W Word R/W Word R/W Word Read Byte Read Word Read Byte Read Byte Read Byte Read Byte Read Word Read Word Read Word Read Word Read Byte Read Byte Read Byte Read Word Block R/W Block R/W Block R/W R/W Word R/W Word R/W Word R/W Word R/W Word R/W Word R/W Word Block Read Block Read R/W Word R/W Word R/W Word Block R/W Read Word R/W Word R/W Word — R/W R/W R/W R/W R/W R R R R R — R R — — R R R R R/W R/W R/W R/W R/W R/W — R/W R/W R/W R R R/W — — — — — — PAGE 5 PAGE 6–11 (NOTE — — — — — — R R — R — R — — — R R R R R R/W R/W R/W R/W — — — — — R/W R R — — R/W R/W R R/W R/W 1) R/W — — — — — R R — R R — — — R — R R R R R/W R/W R/W R/W — — R/W — — R/W R R — R/W — — — — — PAGE 255 — — — — — — R R — R — — — — — — R R R R R/W R/W R/W R/W — — — — — R/W R R — — — — — — — NO. OF BYTES FLASH STORED (NOTE 2) DEFAULT VALUE (NOTE 2) 2 2 2 2 2 2 1 2 1 1 1 1 2 2 2 2 1 1 1 2 8 8 8 2 2 2 2 2 2 2 255 4 2 2 2 32 2 2 2 Y Y Y Y Y Y N N N N N N N N N N FIXED FIXED FIXED FIXED Y Y Y Y N N N N Y Y Y N Y Y Y Y N Y Y 7FFFh 0000h 0000h 0000h 0000h 0000h 00h 0000h 00h 00h 00h 00h 0000h 0000h 0000h 0000h 11h 4Dh 52h 3030h (Note 3) (Note 3) (Note 3) 0000h 0000h 0000h 8000h 7FFFh 0000h 0000h (Note 4) (Note 5) 0000h 0000h 0000h (Note 6) 0000h 0000h 0000h Note 1: Common commands are shaded. Access through any page results in the same device response. Note 2: In the Flash Stored column, an “N” indicates that this parameter is not stored in flash memory when the STORE_ DEFAULT_ALL command is executed and the value shown in the Default Value column is automatically loaded upon power-on reset or when the RST pin is asserted. A “Y” in the Flash Stored column indicates that the currently loaded value in this parameter is stored in flash memory when the STORE_DEFAULT_ALL command is executed and is automatically 15 MAX34441 Table 1. PMBus Command Codes (continued) MAX34441 PMBus 5-Channel Power-Supply Manager and Intelligent Fan Controller Table 1. PMBus Command Codes (continued) Note Note Note Note 3: 4: 5: 6: loaded upon power-on reset or when the RST pin is asserted and the value shown in the Default Value column is the value when shipped from the factory. “FIXED” in the Flash Stored column means this value is fixed at the factory and cannot be changed. The factory-set default value for this 8-byte block is 3130313031303130h. The factory-set default value for the complete block of the MFR_NV_FAULT_LOG is FFh. The power-on reset value for this 4-byte block is 00000000h. The factory-set default value for the complete block of the MFR_FAN_LUT is 00h. Address Select Table 2. PMBus/SMBus Serial-Port Address A1 7-BIT SLAVE ADDRESS A0 100kI to VSS 100kI to VDD On device power-up, the device samples the A0 and A1 pins to determine the PMBus/SMBus serial-port address. SMBus/PMBus Operation 100kI to VSS 1101 010 (D4h) 100kI to VDD 1101 011 (D6h) 100kI to VSS 1101 100 (D8h) 100kI to VDD 1101 101 (DAh) The device implements the PMBus command structure using the SMBus format. The structure of the data flow between the host and the slave is shown below for several different types of transactions. All transactions begin with a host sending a command code that is immediately preceded with a 7-bit slave address (R/W = 0). Data is sent most significant bit (MSB) first. SMBus/PMBus Communication Examples READ WORD FORMAT 1 7 S SLAVE ADDRESS 1 W 1 8 A COMMAND CODE 1 1 7 A Sr SLAVE ADDRESS 1 1 8 1 8 1 1 R A DATA BYTE LOW A DATA BYTE HIGH NA P READ BYTE FORMAT 1 7 1 1 8 1 1 7 1 1 8 1 1 S SLAVE ADDRESS W A COMMAND CODE A Sr SLAVE ADDRESS R A DATA BYTE NA P 1 8 1 8 A COMMAND CODE A DATA BYTE LOW WRITE WORD FORMAT 1 7 S SLAVE ADDRESS 1 W 1 8 1 1 A DATA BYTE HIGH A P WRITE BYTE FORMAT 1 7 S SLAVE ADDRESS 1 W 1 8 1 8 1 1 A COMMAND CODE A DATA BYTE A P SEND BYTE FORMAT 16 1 7 1 1 8 1 1 S SLAVE ADDRESS W A COMMAND CODE A P KEY: S = START Sr = REPEATED START P = STOP W = WRITE BIT (0) R = READ BIT (1) A = ACKNOWLEDGE (0) NA = NOT ACKNOWLEDGE (1) SHADED BLOCK = SLAVE TRANSACTION PMBus 5-Channel Power-Supply Manager and Intelligent Fan Controller continuous data stream. All the devices addressed during this transaction wait for the host to issue a STOP before beginning to respond to the command. Group Command Write Format SLAVE ADDRESS, COMMAND BYTE, AND DATA WORD FOR DEVICE 1 1 7 S SLAVE ADDRESS 1 W 1 8 A COMMAND CODE 1 8 A DATA BYTE LOW 1 8 1 A DATA BYTE HIGH A UUU SLAVE ADDRESS, COMMAND BYTE, AND DATA BYTE FOR DEVICE 2 1 7 Sr SLAVE ADDRESS 1 W 1 8 1 8 1 A COMMAND CODE A DATA BYTE A UUU KEY: S = START Sr = REPEATED START SLAVE ADDRESS AND SEND BYTE FOR DEVICE 3 1 7 1 1 8 1 Sr SLAVE ADDRESS W A COMMAND CODE A P = STOP W = WRITE BIT (0) UUU A = ACKNOWLEDGE (0) SHADED BLOCK = SLAVE TRANSACTION UUU SLAVE ADDRESS, COMMAND BYTE, AND DATA WORD FOR DEVICE N 1 7 1 1 8 1 8 1 8 1 1 Sr SLAVE ADDRESS W A COMMAND CODE A DATA BYTE LOW A DATA BYTE HIGH A P Addressing The device responds to receiving its fixed slave address by asserting an acknowledge (ACK) on the bus. The device does not respond to a general call address; it only responds when it receives its fixed slave address. The only exception to this operation is if the ALERT output is enabled (ALERT bit = 1 in MFR_MODE) and ALERT has been asserted. When this condition occurs, the device only recognizes the alert response address (0001 100, 18h). See the ALERT and Alert Response Address (ARA) section for more details. ALERT and Alert Response Address (ARA) If the ALERT output is enabled (ALERT bit = 1 in MFR_MODE), when a fault occurs the device asserts the ALERT signal and then waits for the host to send the alert response address (ARA) as shown in the Alert Response Address (ARA) Byte Format section. While waiting for the ARA, the device does not respond to its fixed slave address. When the ARA is received and the device is asserting ALERT, the device ACKs it and then attempts to place its fixed slave address on the bus by arbitrating the bus, since another device could also try to respond to the ARA. The rules of arbitration state that the lowest address device wins. If the device wins the arbitration, it deasserts ALERT and begins to respond to its fixed slave address. If the device loses arbitration, it keeps ALERT asserted and waits for the host to once again send the ARA. 17 MAX34441 Group Command The device supports the group command. With the group command, a host can write different data to multiple devices on the same serial bus with one long MAX34441 PMBus 5-Channel Power-Supply Manager and Intelligent Fan Controller Alert Response Address (ARA) Byte Format 1 7 S ARA 0001100 1 R 1 8 1 1 A DEVICE SLAVE ADDRESS WITH LSB = 0 NA P Host Sends or Reads Too Few Bits If for any reason the host does not complete writing a full byte or reading a full byte from the device before a START or STOP is received, the device does the following: 1) Ignores the command. 2) Sets the CML bit in STATUS_BYTE. 3) Sets the CML bit in STATUS_WORD. 4) Sets the DATA_FAULT bit in STATUS_CML. 5) Notifies the host through ALERT assertion (if enabled). Host Sends or Reads Too Few Bytes For each supported command, the device expects a fixed number of bytes to be written or read from the device. If for any reason fewer than the expected number of bytes is written to or read from the device, the device completely ignores the command and takes no action. Host Sends Too Many Bytes or Bits For each supported command, the device expects a fixed number of bytes to be written to the device. If for any reason more than the expected number of bytes or bits is written to the device, the device does the following: 1) Ignores the command. 2) Sets the CML bit in STATUS_BYTE. 3) Sets the CML bit in STATUS_WORD. 4) Sets the DATA_FAULT bit in STATUS_CML. 5) Notifies the host through ALERT assertion (if enabled). Host Reads Too Many Bytes or Bits For each supported command, the device expects a fixed number of bytes to be read from the device. If for any reason more than the expected number of bytes or bits is read from the device, the device does the following: 1) Sends all ones (FFh) as long as the host keeps acknowledging. 2) Sets the CML bit in STATUS_BYTE. 3) Sets the CML bit in STATUS_WORD. 4) Sets the DATA_FAULT bit in STATUS_CML. 5) Notifies the host through ALERT assertion (if enabled). 18 Host Sends Improperly Set Read Bit in the Slave Address Byte If the device receives the R/W bit in the slave address set to one immediately preceding the command code, the device does the following (note this does not apply to ARA): 1) ACKs the address byte. 2) Sends all ones (FFh) as long as the host keeps acknowledging. 3) Sets the CML bit in STATUS_BYTE. 4) Sets the CML bit in STATUS_WORD. 5) Sets the DATA_FAULT bit in STATUS_CML. 6) Notifies the host through ALERT assertion (if enabled). Unsupported Command Code Received If the host sends the device a command code that it does not support, or if the host sends a command code that is not supported by the current PAGE setting, the device does the following: 1) Ignores the command. 2) Sets the CML bit in STATUS_BYTE. 3) Sets the CML bit in STATUS_WORD. 4) Sets the COMM_FAULT bit in STATUS_CML. 5) Notifies the host through ALERT assertion (if enabled). Invalid Data Received The device checks the PAGE, OPERATION, and WRITE_PROTECT command codes for valid data. If the host writes a data value that is invalid, the device does the following: 1) Ignores the command. 2) Sets the CML bit in STATUS_BYTE. 3) Sets the CML bit in STATUS_WORD. 4) Sets the DATA_FAULT bit in STATUS_CML. 5) Notifies the host through ALERT assertion (if enabled). PMBus 5-Channel Power-Supply Manager and Intelligent Fan Controller 1) ACKs the address byte. 2) Ignores the command. 3) Sends all ones (FFh) as long as the host keeps acknowledging. 4) Sets the CML bit in STATUS_BYTE. 5) Sets the CML bit in STATUS_WORD. 6) Sets the DATA_FAULT bit in STATUS_CML. 7) Notifies the host through ALERT assertion (if enabled). Host Writes to a Read-Only Command When a write request is issued to a read-only command, the device does the following: 1) Ignores the command. 2) Sets the CML bit in STATUS_BYTE. 3) Sets the CML bit in STATUS_WORD. 4) Sets the COMM_FAULT bit in STATUS_CML. 5) Notifies the host through ALERT assertion (if enabled). SMBus Timeout If during an active SMBus communication sequence the SCL signal is held low for greater than the timeout duration (nominally 30ms), the device terminates the sequence and resets the serial bus. It takes no other action. No status bits are set. PMBus Operation From a software perspective, the device appears as a PMBus device capable of executing a subset of PMBus commands. A PMBus 1.1-compliant device uses the SMBus version 1.1 for transport protocol and responds to the SMBus slave address. In this data sheet, the term SMBus is used to refer to the electrical characteristics of the PMBus communication using the SMBus physical layer. The term PMBus is used to refer to the PMBus command protocol. The device employs a number of standard SMBus protocols such as Write Word, Read Word, Write Byte, Read Byte, Send Byte, and so on to program output voltage and warning/faults thresholds, read monitored data, and provide access to all manufacturer-specific commands. The device supports the group command. The group command is used to send commands to more than one PMBus device. It is not required that all the devices receive the same command. However, no more than one command can be sent to any one device in one group command packet. The group command must not be used with commands that require receiving devices to respond with data, such as the STATUS_BYTE command. When the device receives a command through this protocol, it immediately begins execution of the received command after detecting the STOP condition. The device supports the PAGE command and uses it to select which individual channel to access. When a data word is transmitted, the lower order byte is sent first and the higher order byte is sent last. Within any byte, the most significant bit (MSB) is sent first and the least significant bit (LSB) is sent last. PMBus Protocol Support The device supports a subset of the commands defined in the PMBus™ Power System Management Protocol Specification Part II - Command Language, Revision 1.1. For detailed specifications and the complete list of PMBus commands, refer to Part II of the PMBus specification available at www.PMBus.org. The supported PMBus commands and the corresponding device behavior are described in this document. All data values are represented in DIRECT format, unless otherwise stated. Whenever the PMBus specification refers to the PMBus device, it is referring to the MAX34441 operating in conjunction with a power supply or fan. While the command can call for turning on or turning off the PMBus device, the MAX34441 always remains on to continue communicating with the PMBus master, and the MAX34441 transfers the command to the power supply accordingly. Data Format Voltage data for commanding or reading the output voltage or related parameters (such as the overvoltage threshold) is presented in DIRECT format. DIRECT format data is a 2-byte, two’s complement binary value. DIRECT format data can be used with any command that sends or reads a parametric value. The DIRECT format uses an equation and defined coefficients to calculate the desired values. Table 3 shows the coefficients used by the device. 19 MAX34441 Host Reads from a Write-Only Command When a read request is issued to a write-only command (CLEAR_FAULTS, STORE_DEFAULT_ALL, RESTORE_DEFAULT_ALL), the device does the following: MAX34441 PMBus 5-Channel Power-Supply Manager and Intelligent Fan Controller Table 3. PMBus Command Code Coefficients PARAMETER UNITS RESOLUTION MAX m b R Voltage VOUT_MARGIN_HIGH VOUT_MARGIN_LOW VOUT_OV_FAULT_LIMIT VOUT_OV_WARN_LIMIT VOUT_UV_WARN_LIMIT VOUT_UV_FAULT_LIMIT POWER_GOOD_ON POWER_GOOD_OFF READ_VOUT MFR_VOUT_PEAK MFR_VOUT_MIN mV 1 32,767 1 0 0 Voltage Scaling VOUT_SCALE_MONITOR — 1/32,767 1 32,767 0 0 Current IOUT_OC_WARN_LIMIT IOUT_OC_FAULT_LIMIT READ_IOUT MFR_IOUT_PEAK mA 1 32,767 1 0 0 IOUT_CAL_GAIN mI 0.1 3276.7 1 0 1 OT_FAULT_LIMIT OT_WARN_LIMIT READ_TEMPERATURE_1 MFR_TEMPERATURE_PEAK NC 0.01 327.67 1 0 2 READ_FAN_SPEED_1 FAN_COMMAND_1 MFR_FAN_FAULT_LIMIT MFR_FAN_WARN_LIMIT RPM 1 32,767 1 0 0 FAN_COMMAND_1 MFR_READ_FAN_PWM MFR_FAN_FAULT_LIMIT MFR_FAN_WARN_LIMIT % 0.01 327.67 1 0 2 TON_DELAY TON_MAX_FAULT_LIMIT TOFF_DELAY MFR_FAULT_RETRY ms 1 32,767 1 0 0 Current Scaling Temperature Fan Speed Timing COMMANDS Interpreting Received DIRECT Format Values The host system uses the following equation to convert the value received from the PMBus device—in this case, the MAX34441—into a reading of volts, degrees Celsius, or other units as appropriate: X = (1/m) x (Y x 10-R - b) where X is the calculated, real world value in the appropriate units (V, NC, etc.); m is the slope coefficient; Y is the 2-byte, two’s complement integer received from the PMBus device; b is the offset; and R is the exponent. 20 Sending a DIRECT Format Value To send a value, the host must use the below equation to solve for Y: Y = (mX + b) x 10R where Y is the 2-byte, two’s complement integer to be sent to the unit; m is the slope coefficient; X is the real world value, in units such as volts, to be converted for transmission; b is the offset; and R is the exponent. PMBus 5-Channel Power-Supply Manager and Intelligent Fan Controller Table 4. Coefficients for DIRECT Format Value COMMAND CODE COMMAND NAME m b R 25h VOUT_MARGIN_HIGH 1 0 0 8Bh READ_VOUT 1 0 0 The host sends the SMBus ARA (0001 100). The device ACKs the SMBus ARA, transmits its slave address, and deasserts ALERT. The system controller then communicates with PMBus commands to retrieve the fault/warning status information from the device. See the individual command sections for more details. Faults and warnings that are latched in the status registers are cleared when any one of the following conditions occurs: • A CLEAR_FAULTS command is received. • The RST pin is toggled. If a host wants to set the device to change the powersupply output voltage to 3.465V (or 3465mV), the corresponding VOUT_MARGIN_HIGH value is: • Bias power to the device is removed and then reapplied. Y = (1 x 3465 + 0) x 100 = 3465 (decimal) = 0D89h (hex) • The output is commanded through the CONTROL pin, the OPERATION command, to turn off and then turn back on. Conversely, if the host received a value of 0D89h on a READ_VOUT command, this is equivalent to: X = (1/1) x (0D89h x 10-(-0) - 0) = 3465mV = 3.465V Power supplies and power converters generally have no way of knowing how their outputs are connected to ground. Within the power supply, all output voltages are most commonly treated as positive. Accordingly, all output voltages and output voltage-related parameters of PMBus devices are commanded and reported as positive values. It is up to the system to know that a particular output is negative if that is of interest to the system. All output-voltage-related commands use 2 data bytes. Fault Management and Reporting For reporting faults/warnings to the host on a real-time basis, the device asserts the open-drain ALERT pin (if enabled in MFR_MODE) and sets the appropriate bit in the various status registers. On recognition of the ALERT assertion, the host or system manager is expected to poll the I2C bus to determine the device asserting ALERT. One or more latched-off power supplies is only restarted when one of the following occurs: • The RST pin is toggled. • Bias power to the device is removed and then reapplied. A power supply is not allowed to turn on if any faults the supply responds to are detected. Only after the faults clear is the power supply allowed to turn on. When global supplies are being sequenced on, a fault on any of the supplies keeps all supplies from being turned on. A system-wide power-up (OPERATION command is received to turn the supplies on when PAGE is 255 or the CONTROL pin is toggled to turn on the supplies) allows all enabled power supplies to power-up. If any faults are detected once the supplies start to turn on, the response of MFR_FAULT_RESPONSE is performed. The device responds to fault conditions according to the manufacturer fault response command (MFR_FAULT_RESPONSE). This command byte determines how the device should respond to each Table 5. Device Parametric Monitoring States PARAMETER Overvoltage REQUIRED CONDITIONS FOR ACTIVE MONITORING Power Supply Enabled (TON_MAX_FAULT_LIMIT ≠ 0000h) Undervoltage • • • Power Supply Enabled (TON_MAX_FAULT_LIMIT ≠ 0000h) PSEN Output is Active Channel’s VOUT > POWER_GOOD_ON Overcurrent • • Power Supply Enabled (TON_MAX_FAULT_LIMIT ≠ 0000h) Current Monitoring Enabled (IOUT_OC_FAULT_LIMIT ≠ 0000h) Power-Up Time Overtemperature Fan Speed Power Supply Enabled (TON_MAX_FAULT_LIMIT ≠ 0000h) ACTION DURING A FAULT Continue Monitoring Stop Monitoring While the Power Supply is Off Continue Monitoring Monitor Only During Power-On Temp Sensor Enabled (ENABLE in MFR_TEMP_SENSOR_CONFIG = 1) Continue Monitoring Fan Enabled (Bit 7 in FAN_CONFIG_1_2 = 1) Continue Monitoring 21 MAX34441 The following example demonstrates how the host can send and retrieve values from the device. Table 4 shows the coefficients used in the following parameters. MAX34441 PMBus 5-Channel Power-Supply Manager and Intelligent Fan Controller particular fault. Table 5 illustrates the required conditions and fault actions for specific parameters. System Watchdog Timer The device uses an internal watchdog timer that is internally reset every 5ms. In the event that the device is locked up and this watchdog reset does not occur after 500ms, the device automatically resets. After the reset occurs, the device reloads all configuration values that were stored to flash and begins normal operation. After the reset, the device also does the following: 1) Sets the NONE OF THE ABOVE bit in STATUS_BYTE. 2) Sets the NONE OF THE ABOVE and MFR bits in STATUS_WORD. 3) Sets the WATCHDOG bit in STATUS_MFR_SPECIFIC. 4) Notifies the host through ALERT assertion (if enabled in MFR_MODE). Temperature Sensor Operation The device can monitor up to six different temperature sensors. It can monitor up to four remote I2C-based temperature sensors plus a remote diode and its own internal temperature sensor. Each of the enabled temperature sensors is measured once a second. The remote diode and internal temperature sensors are averaged four times to reduce the affect of noise. Each time the device attempts to read a temperature sensor it checks for faults. For the remote diode, a fault is defined as reading greater than +160NC or less than -60NC. For the internal temperature sensor, a fault is defined as reading greater than +130NC or less than -60NC. For the I2C temperature sensors, a fault is defined as a communication access failure. Temperature sensor faults are reported by setting the temperature reading to 7FFFh. A temperature sensor fault results in the setting of the TEMPERATURE bit in STATUS_BYTE and STATUS_WORD and ALERT is asserted (if enabled in MFR_MODE). No bits are set in STATUS_MFR_SPECIFIC. The temperatures do not have to be used to control the fan speed. They can be enabled and used for temperature monitoring only. Reading disabled temperature sensors returns a fixed value of 0000h. The remote diode temperature sensor can support either npn or pnp transistors. The device automatically cancels the series resistance that can affect remote diodes that are located far from the device. The device can control up to four DS75LV digital temperature sensors. The A0, A1, and A2 pins on the DS75LV 22 Table 6. DS75LV Address Pin Configurations DS75LV ADDRESS PIN CONFIGURATION PAGE MAX34441 I2C TEMP SENSOR A2 A1 A0 7 TEMP SENSOR I2C 0 0 0 0 8 TEMP SENSOR I2C 1 0 0 1 9 TEMP SENSOR I2C 2 TEMP SENSOR I2C 3 0 1 0 0 1 1 10 should be configured as shown in Table 6. The thermostat function on the DS75LV is not used and thus the O.S. output should be left open circuit. Fan Control Operation Fan control has four operational modes. The mode is determined by the combination of FAN_COMMAND_1 and bit 6 of FAN_CONFIG_1_2 (see Table 7). Fan control can be disabled by setting bit 7 in FAN_CONFIG_1_2 to zero. Dual Fan Applications In dual fan applications operating in RPM mode, the tachometer selected when TACHSEL = 0 is closeloop-controlled to the target RPM. Once PWM ramping is complete, TACHSEL toggles between the two tachometers every 500ms for monitoring purposes. The slower of the two tachometer signals is reported by READ_FAN_SPEED_1 and is used as a comparison for fan faults and warning. In dual fan applications operating in PWM mode, TACHSEL always switches every 500ms. If one of the two tachometer signals operate at a slower speed, it is recommended that the slower tachometer be presented to the TACH input when TACHSEL = 0. Automatic Fan Control Operation In the automatic mode, the fan is controlled in a closed loop based on the controlling temperature (the highest postnormalized temperature reading) and the associated fan control PWM duty cycle (in %) or fan speed (in RPM). These parameters are assigned in the fan lookup table (LUT). See the MFR_FAN_LUT description for configuration details. When a controlling temperature exceeds the temperature level programmed in the LUT, the device outputs a PWM duty cycle or adjusts the fan speed, associated with that temperature. See Figure 1 for an example. PMBus 5-Channel Power-Supply Manager and Intelligent Fan Controller FAN CONTROL MODE FAN OPERATIONAL DETAILS BIT 6 OF FAN_CONFIG_1_2 VALUE IN FAN_COMMAND_1 Manual PWM External host controls the fan speed by directly setting the fan PWM duty cycle values. 0 0000h to 7FFFh Manual RPM External host controls the fan speed by setting target fan speed values. The device reads the actual fan speed, and close loop adjusts the output fan PWM to match the target fan speed. 1 0000h to 7FFFh Automatic PWM The device sets the output PWM based on the fan LUT that maps the temperature sensor readings to the required fan PWM duty-cycle values. 0 8000h to FFFFh Automatic RPM The device reads the actual fan speed and close loop adjusts the output fan PWM to match the target fan speed based on the fan LUT that maps the temperature sensor readings to the required fan speed. 1 8000h to FFFFh Note: The RPM modes should only be used with fans that provide a tachometer output. OFFSET ADJUSTMENT ALLOWS TEMPERATURE ZONE NORMALIZATION PAGE 7 I2C REMOTE TEMP SENSOR 0 +15°C PAGE 8 I2C REMOTE TEMP SENSOR 1 +10°C PAGE 9 I2C REMOTE TEMP SENSOR 2 0°C PAGE 10 I2C REMOTE TEMP SENSOR 3 0°C FAN 8 LEVEL LOOKUP TABLE FAN HIGHEST TEMPERATURE CONTROLS THE FAN PAGE 11 REMOTE DIODE TEMP SENSOR +5°C PAGE 6 INTERNAL TEMP SENSOR +5°C Figure 1. Automatic Fan Control 23 MAX34441 Table 7. Fan Control Operation Modes MAX34441 PMBus 5-Channel Power-Supply Manager and Intelligent Fan Controller One or all of the six available temperature sensors can be used to control the fan speed. Each temperature sensor has an offset adjustment that allows monitoring specific temperature zones with different thermal characteristics. In Figure 1, I2C temperature sensor 0 is monitoring a zone that is 15NC more sensitive than the zone that the I2C temperature sensor 3 is measuring. To keep the audible noise and fan power consumption as low as possible, the device allows each temperature sensor to have a temperature offset added. This allows temperature zones with different thermal profiles to control the fan at the lowest possible speed to maintain the required temperature. If no temperature sensors are assigned to control the fan, the output fan PWM signal is ramped to 100% duty cycle. In Figure 2, at temperature sample 1, the required fan speed is at the level associated with temperature level 2 and since temperature sample 1 is above temperature level 3, the fan PWM duty cycle needs to be increased to increase the fan speed. The device increases the fan PWM duty cycle at a rate controlled by the RAMP bits in the MFR_FAN_CONFIG command code. If the PWM duty cycle has not reached the target value before the temperature sample detects that a new PWM target value is needed, the device stops moving toward the old target and starts moving to the new target according to the programmed ramp rate. At temperature sample 2, the temperature has increased to greater than temperature level 4 so again the PWM duty cycle must be increased. At temperature sample 3, the temperature has dropped but not below the thermal hysteresis level (which is set by the HYS bits in the MFR_FAN_CONFIG command code), so the fan speed remains at level 4. At temperature sample 4, the temperature has dropped below the hysteresis point so the PWM duty cycle is decreased. Pulse Stretching In some 3-wire fan applications, when the supply power is interrupted to control fan speed, the tachometer signal is not available. Some fan controllers periodically stretch the PWM signal to allow the tachometer to be accurately detected. Pulse stretching can create audible noise. This device does not implement pulse stretching. Hence, the RPM fan modes that require a reliable tachometer signal to be available at all times should not be used in applications that switch power to the fan to control the speed of the fan. For example, low-side switching of a 3-wire fan should not use either of the RPM fan modes. SENSOR TEMPERATURE FAN SPEED T7 S7 T6 THERMAL HYSTERESIS SAMPLED TEMPERATURES T5 S5 SAMPLE 2 SAMPLE 3 T4 T3 S4 SAMPLE 1 SAMPLE 4 S3 T2 S2 T1 S1 T0 S0 ELAPSED TIME TEMPERATURE SAMPLE RATE (ONCE PER SECOND) Figure 2. Fan Speed Example 24 S6 PMBus 5-Channel Power-Supply Manager and Intelligent Fan Controller 100% SPIN-UP CRITERIA MET AUTOMATIC SPIN-UP ENABLED 90% When spin-up passes, the device forces the fan PWM with a 40% duty cycle. The 40% duty cycle is maintained until the next temperature conversion is completed, which occurs once a second. After the temperature conversion, the device enters either manual mode operation or automatic operation using MFR_FAN_LUT. 80% 70% RAMP PWM TO TARGET PWM OR RPM (CONSTRAINED BY THE RAMP BITS) 60% 50% 40% AUTOMATIC SPIN-UP DISABLED 30% ALWAYS RETURN TO 40% DUTY CYCLE AFTER AUTOMATIC SPIN-UP BEFORE BEGINNING PWM RAMP (EVEN IF BEYOND 1 SECOND) 20% INITIAL TARGET PWM OR RPM DETERMINED AFTER TEMPERATURE CONVERSION 10% 0 0.2 0.4 0.6 0.8 1.0 1.2 1.4 TIME (SECONDS) Figure 3. Fan Spin-Up 25 MAX34441 Fan Spin-Up Figure 3 shows the fan spin-up process. When the fan is spinning up, the number of revolutions is checked every 200ms for up to 2s. When the number of cumulated revolutions is greater than or equal to the spin-up relaxation criteria, the fan passes spin-up. If the fan has a locked rotor output, fan spin-up passes when the locked rotor signal is no longer asserted. MAX34441 PMBus 5-Channel Power-Supply Manager and Intelligent Fan Controller PMBus Commands A summary of the PMBus commands supported by the device are described in the following sections. PAGE (00h) The device can control up to five power supplies, up to six temperature sensors, and a fan using one PMBus (I2C) address. Send the PAGE command with data 0 to 11 to select which power supply or which temperature sensor or fan is affected by all the PMBus commands shown in Table 1. Not all commands are supported within each page. If an unsupported command is received, the CML status bit is set. Some commands are common, meaning that any selected page has the same effect on and the same response from the device. Set the PAGE to 255 when it is desired that the following PMBus commands should apply to all pages at the same time. There are only a few commands (OPERATION, CLEAR_FAULTS) where this function has a real application. Table 8. Page Commands PAGE (DEC) Power Supply Connected to ADC 0 1 Power Supply Connected to ADC 1 2 Power Supply Connected to ADC 2 3 Power Supply Connected to ADC 3 4 Power Supply Connected to ADC 4 5 Fan Connected to PWM 5 6 Internal Temperature Sensor 7 Remote I2C Temperature Sensor with Address 0 8 Remote I2C Temperature Sensor with Address 1 9 Remote I2C Temperature Sensor with Address 2 10 Remote I2C Temperature Sensor with Address 3 11 Remote Thermal-Diode Sensor 12 to 254 255 26 ASSOCIATED CONTROL 0 Reserved Applies to All Pages PMBus 5-Channel Power-Supply Manager and Intelligent Fan Controller USER NOTE: All power supplies tagged as GLOBAL supplies (see MFR_FAULT_RESPONSE) should be turned on and off at the same time. Table 9. OPERATION Command Byte (When Bit 3 of ON_OFF_CONFIG = 1) COMMAND BYTE POWER SUPPLY ON OR OFF MARGIN STATE 00h Immediate Off (No Sequencing) N/A 40h Soft Off (with Sequencing) N/A 80h On Margin Off 94h On Margin Low (Ignore All Faults) Margin Low (Act On Any Fault) 98h On A4h On Margin High (Ignore All Faults) A8h On Margin High (Act On Any Fault) Note: The device only takes action if the supply is enabled. The VOUT of all enabled channels must exceed POWER_GOOD_ON for margining to begin. Table 10. OPERATION Command Byte (When Bit 3 of ON_OFF_CONFIG = 0) COMMAND BYTE POWER SUPPLY ON OR OFF MARGIN STATE 00h Command Has No Effect N/A 40h Command Has No Effect N/A 80h Command Has No Effect Margin Off 94h Command Has No Effect Margin Low (Ignore All Faults) Margin Low (Act On Any Fault) 98h Command Has No Effect A4h Command Has No Effect Margin High (Ignore All Faults) A8h Command Has No Effect Margin High (Act On Any Fault) Note: The device only takes action if the supply is enabled. The VOUT of all enabled channels must exceed POWER_GOOD_ON for margining to begin. 27 MAX34441 OPERATION (01h) The OPERATION command is used to turn the power supply on and off in conjunction with the CONTROL input pin. The OPERATION command is also used to cause the power supply to set the output voltage to the upper or lower margin voltages. The power supply stays in the commanded operating mode until a subsequent OPERATION command or until a change in the state of the CONTROL pin (if enabled) instructs the power supply to change to another state. The valid OPERATION command byte values are shown in Tables 9 and 10. The OPERATION command controls how the device responds when commanded to change the output. When the command byte is 00h, the device immediately turns the power supply off and ignores any programmed turn-off delay. When the command byte is set to 40h, the device powers down according to the programmed turn-off delay. In Tables 9 and 10, “act on any fault” means that if any warning or fault on the selected power supply is detected when the output is margined, the device treats this as a warning or fault and responds as programmed. “Ignore all faults” means that all warnings and faults on the selected power supply are ignored. Any command value not shown in Tables 9 and 10 is an invalid command. If the device receives a data byte that is not listed in Tables 9 and 10, then it treats this as invalid data, declares a data fault (set CML bit and assert ALERT), and responds as described in the Fault Management and Reporting section. MAX34441 PMBus 5-Channel Power-Supply Manager and Intelligent Fan Controller ON_OFF_CONFIG (02h) The ON_OFF_CONFIG command configures the combination of CONTROL input and PMBus OPERATION commands needed to turn the power supply on and off. This indicates how the power supply is commanded when power is applied. Table 11 describes the ON_OFF_CONFIG message content. The host should not modify ON_OFF_CONFIG while the power supplies are active. Table 11. ON_OFF_CONFIG (02h) Command Byte BIT 7:5 4 PURPOSE Reserved BIT VALUE N/A Turn on supplies when bias is present or use the CONTROL pin and/or OPERATION command 3 OPERATION Command Enable 2 CONTROL Pin Enable 1 CONTROL Pin Polarity 0 CONTROL Pin Turn-Off Action MEANING Always returns 000. 0 Turn on the supplies (with sequencing, if so configured) as soon as bias is supplied to the device regardless of the CONTROL pin. 1 Operate the supplies as instructed by the CONTROL pin and/or the OPERATION command. 0 Ignore the on/off portion of the OPERATION command. 1 OPERATION command enabled and required for action. 0 Ignore the CONTROL pin. 1 CONTROL pin enabled and required for action. 0 Active low (drive low to turn on the power supplies). 1 Active high (drive high to turn on the power supplies). 0 Use the programmed turn-off delay (soft off). 1 Turn off the power supplies immediately. CLEAR_FAULTS (03h) The CLEAR_FAULTS command is used to clear any fault or warning bits in the status registers that have been set. This command clears all bits simultaneously. The CLEAR_FAULTS command does not cause a power supply that has latched off for a fault condition to restart. The status of PSEN under fault conditions is not affected by this command and changes only if commanded through the OPERATION command or CONTROL pin. If a fault is still present after the CLEAR_FAULTS command is executed, the fault status bit is set again and the host is also notified by asserting ALERT (if enabled in MFR_MODE). This command is write-only. There is no data byte for this command. WRITE_PROTECT (10h) The WRITE_PROTECT command is used to provide protection against accidental changes to the device operating memory. All supported commands can have their parameters read, regardless of the WRITE_PROTECT settings. The WRITE_PROTECT message content is described in Table 12. Table 12. WRITE_PROTECT Command Byte COMMAND BYTE MEANING 80h Disable all writes except the WRITE_PROTECT command. 40h Disable all writes except the WRITE_PROTECT, OPERATION, and PAGE commands. 20h Disable all writes except the WRITE_PROTECT, OPERATION, PAGE, and ON_OFF_CONFIG commands. 00h Enable writes for all commands (default). Note: No fault or error is generated if the host attempts to write to a protected area. 28 PMBus 5-Channel Power-Supply Manager and Intelligent Fan Controller USER NOTE: VDD must be above 2.9V for the device to perform the STORE_DEFAULT_ALL command. RESTORE_DEFAULT_ALL (12h) The RESTORE_DEFAULT_ALL command transfers the default configuration information from the internal flash memory array to the user memory registers in the device. The RESTORE_DEFAULT_ALL command should only be executed when the device is not operating the power supplies or fans. Upon a device reset, this command is automatically executed by the device without PMBus action required. This command is write-only. There is no data byte for this command. CAPABILITY (19h) The CAPABILITY command is used to determine some key capabilities of the device. The CAPABILITY command is read-only. The message content is described in Table 13. Table 13. CAPABILITY Command Byte BIT 7 6:5 4 3:0 DESCRIPTION MEANING Packet-Error Checking 0 = PEC not supported. PMBus Speed 00 = Maximum supported bus speed is 100kHz. ALERT 1 = Device supports an ALERT output (if ALERT is enabled in MFR_MODE). 0 = Device does not support ALERT output (ALERT is disabled in MFR_MODE). Reserved Always returns 0000. VOUT_MODE (20h) The VOUT_MODE command is used to report the data format of the device. The device uses the DIRECT format for all the voltage-related commands. The value returned is 40h, indicating DIRECT data format. This command is read-only. If a host attempts to write this command, the CML status bit is asserted. See Table 3 for the m, b, and R values for the various commands. VOUT_MARGIN_HIGH (25h) The VOUT_MARGIN_HIGH command loads the device with the voltage to which the power-supply output is to be changed when the OPERATION command is set to margin high. If the power supply is already operating at margin high, changing VOUT_MARGIN_HIGH has no effect on the output voltage. The device only adjusts the power supply to the new VOUT_MARGIN_HIGH voltage after receiving a new margin high OPERATION command. The 2 data bytes are in DIRECT format. If the device cannot successfully close-loop margin the power supply, the device keeps attempting to margin the supply and does the following: 1) Sets the NONE OF THE ABOVE bit in STATUS_BYTE. 2) Sets the NONE OF THE ABOVE and MFR bits in STATUS_WORD. 3) Sets the MARGIN_FAULT bit in STATUS_MFR_SPECIFIC. 4) Notifies the host through ALERT assertion (if enabled in MFR_MODE). 29 MAX34441 STORE_DEFAULT_ALL (11h) The STORE_DEFAULT_ALL command instructs the device to transfer the device configuration information to the internal flash memory array. Not all information is stored. Only configuration data is stored, not any status, or operational data. If an error occurs during the transfer, ALERT asserts if enabled and the CML bit in STATUS_BYTE and STATUS_WORD is set to 1. No bits are set in STATUS_CML. It is NOT recommended to use the STORE_DEFAULT_ALL command while the device is operating power supplies or fans. The device is unresponsive to PMBus commands and does not monitor power supplies while transferring the configuration. This command is write-only. There is no data byte for this command. MAX34441 PMBus 5-Channel Power-Supply Manager and Intelligent Fan Controller VOUT_MARGIN_LOW (26h) The VOUT_MARGIN_LOW command loads the device with the voltage to which the power-supply output is to be changed when the OPERATION command is set to margin low. If the power supply is already operating at margin low, changing VOUT_MARGIN_LOW has no effect on the output voltage. The device only adjusts the power supply to the new VOUT_MARGIN_LOW voltage after receiving a new margin low OPERATION command. The 2 data bytes are in DIRECT format. If the device cannot successfully close-loop margin the power supply, the device keeps attempting to margin the supply and does the following: 1) Sets the NONE OF THE ABOVE bit in STATUS_BYTE. 2) Sets the NONE OF THE ABOVE and MFR bits in STATUS_WORD. 3) Sets the MARGIN_FAULT bit in STATUS_MFR_SPECIFIC. 4) Notifies the host through ALERT assertion (if enabled in MFR_MODE). VOUT_SCALE_MONITOR (2Ah) VOUT_SCALE_MONITOR is used in applications where the measured power-supply voltage is not equal to the voltage at the ADC input. For example, if the ADC input expects a 1.0V input for a 12V output, VOUT_SCALE_MONITOR = 1.0V/12V = 0.0833. In applications where the power-supply output voltage is greater than the device input range, the output voltage of the power supply is sensed through a resistive voltage-divider. The resistive voltage-divider reduces or scales the output voltage. The PMBus commands specify the actual power-supply output voltages and not the input voltage to the ADC. To allow the device to map between the power-supply voltage (such as 12V) and the voltage at the ADC input, the VOUT_SCALE_MONITOR command is used. The 2 data bytes are in DIRECT format. This value is dimensionless. For example, if the required scaling factor is 0.0833, then VOUT_SCALE_MONITOR should be set to 0AABh (2731/32,767 = 0.0833). Table 14. VOUT_SCALE_MONITOR NOMINAL VOLTAGE LEVEL MONITORED (V) NOMINAL ADC INPUT VOLTAGE LEVEL (V) (SEE NOTE) RESISTIVE VOLTAGEDIVIDER RATIO VOUT_SCALE_MONITOR VALUE (HEX) 1.2 1.0 0.833 6AAAh 1.5 1.0 0.667 5555h 1.8 1.0 0.555 470Ah 2.5 1.0 0.4 3333h 3.3 1.0 0.303 26C8h 5 1.0 0.2 1999h 12 1.0 0.0833 0AABh Note: On the device, the full-scale ADC voltage is 1.225V. A scaling factor where a 1.0V ADC input represents a nominal 100% voltage level is recommended. IOUT_CAL_GAIN (38h) The IOUT_CAL_GAIN command is used to set the ratio of the voltage at the ADC input to the sensed current. The units of the IOUT_CAL_GAIN factor are 0.1mI. The 2 data bytes are in DIRECT format. For example, if a 10mI sense resistor is used with a 50V/V current-sense amplifier, the IOUT_CAL_GAIN should be set to 500mI or 1388h. USER NOTE: On the device, the full-scale ADC voltage is 1.225V. The value of the sense resistor and currentsense amplifier gain must be scaled appropriately. 30 PMBus 5-Channel Power-Supply Manager and Intelligent Fan Controller Table 15. FAN_CONFIG_1_2 Command Byte BIT NAME 7 FAN ENABLE 6 RPM/PWM 5:4 PULSE 3:0 0 MEANING 0 = Fan disabled (PWM5 forced low). 1 = Fan enabled. 0 = PWM duty cycle is the fan-controlling parameter. 1 = RPM is the fan-controlling parameter. 00 01 10 11 = = = = 1 2 3 4 Tach Tach Tach Tach pulse per fan revolution. pulses per fan revolution. pulses per fan revolution. pulses per fan revolution. These bits always return a 0. FAN_COMMAND_1 (3Bh) The FAN_COMMAND_1 command is used to override the device’s automatic fan-control function and force the fan to either a fixed PWM duty-cycle value or a target fan speed (in RPM). The units of the FAN_COMMAND_1 are either percent duty cycle (if bit 6 of FAN_CONFIG_1_2 is zero) or RPM (if bit 6 of FAN_CONFIG_1_2 is one). Any value less than 0% duty cycle or 0 RPM causes the device to ignore this command and use the automatic fan-control function. Any value greater than or equal to 0% duty cycle or 0 RPM causes the device to ignore the automatic fan-control function and force the fan to the PWM value or RPM value provided by the FAN_COMMAND_1 command. The 2 data bytes are in DIRECT format. Table 16. PWM Fan Mode (FAN_CONFIG_1_2 Bit 6 = 0) FAN_COMMAND_1 VALUE DEVICE RESPONSE 8000h to FFFFh Ignore FAN_COMMAND_1 and use automatic fan-control function 0000h to 2710Fh 0 to 100% fan PWM duty cycle 2711h to 7FFFh 100% fan PWM duty cycle Table 17. RPM Fan Mode (FAN_CONFIG_1_2 Bit 6 = 1) FAN_COMMAND_1 VALUE DEVICE RESPONSE 8000h to FFFFh Ignore FAN_COMMAND_1 and use automatic fan-control function 0000h to 7FFFh 0 to 32,767 RPM 31 MAX34441 FAN_CONFIG_1_2 (3Ah) The FAN_CONFIG_1_2 command is used in conjunction with MFR_FAN_CONFIG to configure the fan. See the MFR_FAN_CONFIG (F1h) section for more details on this command. The FAN_CONFIG_1_2 command is described in Table 15. MAX34441 PMBus 5-Channel Power-Supply Manager and Intelligent Fan Controller VOUT_OV_FAULT_LIMIT (40h) The VOUT_OV_FAULT_LIMIT command sets the value of the output voltage that causes an output overvoltage fault. The 2 data bytes are in DIRECT format. In response to the VOUT_OV_FAULT_LIMIT being exceeded, the device does the following: 1) Sets the VOUT_OV bit in STATUS_BYTE. 2) Sets the VOUT_OV and VOUT bits in STATUS_WORD. 3) Sets the VOUT_OV_FAULT bit in STATUS_VOUT. 4) Responds as specified in the MFR_FAULT_RESPONSE. 5) Notifies the host through ALERT assertion (if enabled in MFR_MODE). VOUT_OV_WARN_LIMIT (42h) The VOUT_OV_WARN_LIMIT command sets the value of the output voltage that causes an output-voltage high warning. This value is typically less than the output overvoltage threshold in VOUT_OV_FAULT_LIMIT. The 2 data bytes are in DIRECT format. In response to the VOUT_OV_WARN_LIMIT being exceeded, the device does the following: 1) Sets the NONE OF THE ABOVE bit in STATUS_BYTE. 2) Sets the NONE OF THE ABOVE and VOUT bits in STATUS_WORD. 3) Sets the VOUT_OV_WARN bit in STATUS_VOUT. 4) Notifies the host using ALERT assertion (if enabled in MFR_MODE). VOUT_UV_WARN_LIMIT (43h) The VOUT_UV_WARN_LIMIT command sets the value of the output voltage that causes an output-voltage low warning. This value is typically greater than the output undervoltage fault threshold in VOUT_UV_FAULT_LIMIT. This warning is masked until the output voltage reaches the programmed POWER_GOOD_ON voltage at startup, and also during turn-off when the power supply is disabled. The 2 data bytes are in DIRECT format. In response to violation of the VOUT_UV_WARN_LIMIT, the device does the following: 1) Sets the NONE OF THE ABOVE bit in STATUS_BYTE. 2) Sets the NONE OF THE ABOVE and VOUT bits in STATUS_WORD. 3) Sets the VOUT_UV_WARN bit in STATUS_VOUT. 4) Notifies the host using ALERT assertion (if enabled in MFR_MODE). VOUT_UV_FAULT_LIMIT (44h) The VOUT_UV_FAULT_LIMIT command sets the value of the output voltage that causes an output undervoltage fault. This fault is masked until the output voltage reaches the programmed POWER_GOOD_ON voltage at startup, and also during turn-off when the power supply is disabled. The VOUT_UV_FAULT_LIMIT threshold is also used to determine if TON_MAX_FAULT_LIMIT is exceeded. The 2 data bytes are in DIRECT format. In response to violation of the VOUT_UV_FAULT_LIMIT, the device does the following: 1) Sets the NONE OF THE ABOVE bit in STATUS_BYTE. 2) Sets the NONE OF THE ABOVE and VOUT bits in STATUS_WORD. 3) Sets the VOUT_UV_FAULT bit in STATUS_VOUT. 4) Responds as specified in MFR_FAULT_RESPONSE. 5) Notifies the host using ALERT assertion (if enabled in MFR_MODE). 32 PMBus 5-Channel Power-Supply Manager and Intelligent Fan Controller 1) Sets the NONE OF THE ABOVE bit in STATUS_BYTE. 2) Sets the NONE OF THE ABOVE, IOUT, and MFR bits in STATUS_WORD. 3) Sets the OC_WARN bit in STATUS_MFR_SPECIFIC. 4) Notifies the host using ALERT assertion (if enabled in MFR_MODE). IOUT_OC_FAULT_LIMIT (4Ah) The IOUT_OC_FAULT_LIMIT command sets the value of the current that causes an overcurrent fault. The factory default value for IOUT_OC_FAULT_LIMIT is 0000h. This value disables the device from measuring current. Any nonzero positive value written to IOUT_OC_FAULT_LIMIT causes the device to enable current measurement. The 2 data bytes are in DIRECT format. In response to violation of the IOUT_OC_FAULT_LIMIT, the device does the following: 1) Sets the IOUT_OC bit in STATUS_BYTE. 2) Sets the IOUT, IOUT_OC, and MFR bits in STATUS_WORD. 3) Sets the OC_FAULT bit in STATUS_MFR_SPECIFIC. 4) Responds as specified in the MFR_FAULT_RESPONSE. 5) Notifies the host using ALERT assertion (if enabled in MFR_MODE). Table 18. IOUT_OC_FAULT_LIMIT IOUT_OC_FAULT_LIMIT VALUE 8000h to FFFFh DEVICE RESPONSE (ON THE ASSOCIATED PAGE) Negative values are invalid. 0000h Current measurement disabled. 0001h to 7FFFh Current measurement enabled. OT_FAULT_LIMIT (4Fh) The OT_FAULT_LIMIT command sets the temperature, in degrees Celsius, of the selected temperature sensor at which an overtemperature fault is detected. The 2 data bytes are in DIRECT format. In response to the OT_FAULT_LIMIT being exceeded, the device does the following: 1) Sets the TEMPERATURE bit in STATUS_BYTE. 2) Sets the TEMPERATURE and MFR bits in STATUS_WORD. 3) Sets the OT_FAULT bit in STATUS_MFR_SPECIFIC. 4) Responds as specified in MFR_FAULT_RESPONSE. 5) Notifies the host using ALERT assertion (if enabled in MFR_MODE). 33 MAX34441 IOUT_OC_WARN_LIMIT (46h) The IOUT_OC_WARN_LIMIT command sets the value of the current that causes an overcurrent warning. This value is typically less than the overcurrent fault threshold in IOUT_OC_FAULT_LIMIT. The 2 data bytes are in DIRECT format. In response to violation of the IOUT_OC_WARN_LIMIT, the device does the following: MAX34441 PMBus 5-Channel Power-Supply Manager and Intelligent Fan Controller OT_WARN_LIMIT (51h) The OT_WARN_LIMIT command sets the temperature, in degrees Celsius, of the selected temperature sensor at which an overtemperature warning is detected. The 2 data bytes are in DIRECT format. In response to the OT_WARN_LIMIT being exceeded, the device does the following: 1) Sets the TEMPERATURE bit in STATUS_BYTE. 2) Sets the TEMPERATURE and MFR bits in STATUS_WORD. 3) Sets the OT_WARN bit in STATUS_MFR_SPECIFIC. 4) Notifies the host through ALERT assertion (if enabled in MFR_MODE). POWER_GOOD_ON (5Eh) The POWER_GOOD_ON command sets the value of the output voltage that causes the PG output (if enabled in MFR_MODE) to assert. All enabled power supplies must be above their associated POWER_GOOD_ON thresholds before the PG output is asserted. All the enabled power supplies must also be above POWER_GOOD_ON for powersupply margining to begin. The POWER_GOOD_ON level is normally set higher than the POWER_GOOD_OFF level and VOUT_UV_FAULT_LIMIT. The 2 data bytes are in DIRECT format. POWER_GOOD_OFF (5Fh) The POWER_GOOD_OFF command sets the value of the output voltage that causes the PG output (if enabled in MFR_MODE) to deassert after it has been asserted. Any enabled power supply that falls below the associated POWER_GOOD_OFF threshold causes the PG output to be deasserted. The POWER_GOOD_OFF level is normally set lower than the POWER_GOOD_ON level. The 2 data bytes are in DIRECT format. The POWER_GOOD# bits in STATUS_WORD and STATUS_MFR_SPECIFIC are set when the VOUT level of a power supply falls from greater than POWER_GOOD_ON to less than POWER_GOOD_OFF. OPERATION COMMAND CODE OR CONTROL PIN TON_DELAY TOFF_DELAY PSEN PIN (ACTIVE HIGH OR LOW/ OPEN DRAIN OR PUSH-PULL) TON_MAX_FAULT_LIMIT POWER_GOOD_ON VOUT_UV_FAULT_LIMIT ADC INPUT POWER_GOOD# BIT IN STATUS_MFR_SPECIFIC Figure 4. Power-Supply Sequencing 34 POWER_GOOD_OFF PMBus 5-Channel Power-Supply Manager and Intelligent Fan Controller TON_MAX_FAULT_LIMIT (62h) The TON_MAX_FAULT_LIMIT sets an upper time limit, in milliseconds, from when the TON_DELAY and the PSEN output are asserted until the output voltage crosses the VOUT_UV_FAULT_LIMIT threshold. The 2 data bytes are in DIRECT format. If the value is 0, the power supply is not sequenced by the device and the associated PSEN output remains deasserted; voltage and current monitoring is disabled. In response to the TON_MAX_FAULT_LIMIT being exceeded, the device does the following: 1) Sets the NONE OF THE ABOVE bit in STATUS_BYTE. 2) Sets the NONE OF THE ABOVE and VOUT bits in STATUS_WORD. 3) Sets the TON_MAX_FAULT bit in STATUS_VOUT. 4) Responds as specified in the MFR_FAULT_RESPONSE. 5) Notifies the host using ALERT assertion (if enabled in MFR_MODE). Table 19. TON_MAX_FAULT_LIMIT TON_MAX_FAULT_LIMIT VALUE 8000h to FFFFh 0000h DEVICE RESPONSE (FOR THE ASSOCIATED PAGE) Negative values are invalid. Channel off (PSEN remains deasserted with no monitoring). 0001h to 7FFFh Channel on and sequencing enabled. TOFF_DELAY (64h) The TOFF_DELAY sets the time, in milliseconds, from when a STOP condition is received (a soft-off OPERATION command or through the CONTROL pin when enabled) until the PSEN output is deasserted. When commanded to turn off immediately (either through the OPERATION command or the CONTROL pin), the TOFF_DELAY value is ignored. The 2 data bytes are in DIRECT format. STATUS_BYTE (78h) The STATUS_BYTE command returns 1 byte of information with a summary of the most critical faults. A value of 1 indicates that a fault or warning event has occurred and a 0 indicates otherwise. Bits for unsupported features are reported as 0. The STATUS_BYTE cannot be restored by the RESTORE_DEFAULT_ALL command. The STATUS_BYTE message content is described in Table 20. This command is read-only. Table 20. STATUS_BYTE BIT BIT NAME 7:6 0 5 VOUT_OV An overvoltage fault has occurred. 4 IOUT_OC An overcurrent fault has occurred. 3 0 2 TEMPERATURE 1 CML 0 MEANING These bits always return a 0. This bit always returns a 0. A temperature fault or warning has occurred. A communication, memory, or logic fault has occurred. NONE OF THE ABOVE A fault or warning not listed in bits [7:1] has occurred. 35 MAX34441 TON_DELAY (60h) TON_DELAY sets the time, in milliseconds, from when a START condition is received (a valid OPERATION command or through the CONTROL pin when enabled) until the PSEN output is asserted. The undervoltage fault and warning are masked off during TON_DELAY. The 2 data bytes are in DIRECT format. MAX34441 PMBus 5-Channel Power-Supply Manager and Intelligent Fan Controller STATUS_WORD (79h) The STATUS_WORD command returns 2 bytes of information with a summary of the reason for a fault. The low byte of the STATUS_WORD is the same data as the STATUS_BYTE. Table 21 describes the STATUS_WORD message content. Table 21. STATUS_WORD BIT BIT NAME 15 VOUT An output voltage fault or warning or TON_MAX_FAULT has occurred. 14 IOUT An overcurrent fault or warning has occurred. 13 0 12 MFR 11 POWER_GOOD# 10 FANS MEANING This bit always returns a 0. A bit in STATUS_MFR_SPECIFIC has been set. A power-supply voltage has fallen from POWER_GOOD_ON to less than POWER_GOOD_OFF. A fan fault has occurred. 9:6 0 5 VOUT_OV An overvoltage fault has occurred. 4 IOUT_OC An overcurrent fault has occurred. 3 0 2 TEMPERATURE 1 CML 0 These bits always return a 0. This bit always returns a 0. A temperature fault or warning has occurred. A communication, memory, or logic fault has occurred. NONE OF THE ABOVE A fault or warning not listed in bits [7:1] has occurred. STATUS_VOUT (7Ah) The STATUS_VOUT command returns 1 byte of information with contents as described in Table 22. Table 22. STATUS_VOUT BIT BIT NAME 7 VOUT_OV_FAULT VOUT overvoltage fault. MEANING 6 VOUT_OV_WARN VOUT overvoltage warning. 5 VOUT_UV_WARN VOUT undervoltage warning. 4 VOUT_UV_FAULT VOUT undervoltage fault. 3 0 2 TON_MAX_FAULT 1:0 0 This bit always returns a 0. TON maximum fault. These bits always return a 0. STATUS_CML (7Eh) The STATUS_CML command returns 1 byte of information with contents as described in Table 23. Table 23. STATUS_CML 36 BIT BIT NAME MEANING 7 COMM_FAULT An invalid or unsupported command has been received. 6 DATA_FAULT An invalid or unsupported data has been received. 5:1 0 0 FAULT_LOG_FULL These bits always return a 0. MFR_NV_FAULT_LOG is full and needs to be cleared. PMBus 5-Channel Power-Supply Manager and Intelligent Fan Controller Table 24. STATUS_MFR_SPECIFIC BIT BIT NAME 7 OFF MEANING This bit is set if the power supply is off (due to either a fault or sequencing delay; this bit is not set if the power supply is disabled). 6 OT_WARN Overtemperature warning. 5 OT_FAULT Overtemperature fault. 4 WATCHDOG A watchdog reset has occurred. 3 MARGIN_FAULT This bit is set if the device cannot properly close-loop margin the power supply. 2 POWER_GOOD# Power-supply voltage has fallen from POWER_GOOD_ON to less than POWER_GOOD_OFF. 1 OC_FAULT IOUT overcurrent fault. 0 OC_WARN IOUT overcurrent warning. Note: The settings of the OFF and POWER_GOOD# bits do not assert the ALERT signal. STATUS_FANS_1_2 (81h) The STATUS_FANS_1_2 command returns 1 byte of information with the status of the fan. The STATUS_FANS_1_2 command is described in Table 25. Table 25. STATUS_FANS_1_2 BIT BIT NAME 7 FAN_1_FAULT 6 0 5 FAN_1_WARN 4:0 0 MEANING Fan 1 fault. This bit always returns a 0. Fan 1 warning. These bits always return a 0. READ_VOUT (8Bh) The READ_VOUT command returns the actual measured (not commanded) output voltage. READ_VOUT is measured and updated every 5ms. The 2 data bytes are in DIRECT format. READ_IOUT (8Ch) The READ_IOUT command returns the latest measured current value. READ_IOUT is measured and updated every 200ms. The 2 data bytes are in DIRECT format. READ_TEMPERATURE_1 (8Dh) The READ_TEMPERATURE_1 command returns the temperature returned from the temperature sensor. The value of READ_TEMPERATURE_1 does not have offset from MFR_TEMP_SENSOR_CONFIG added. READ_TEMPERATURE_1 returns 7FFFh if the sensor is faulty and 0000h if the sensor is disabled. READ_TEMPERATURE_1 is measured and updated once a second. The 2 data bytes are in DIRECT format. 37 MAX34441 STATUS_MFR_SPECIFIC (80h) The STATUS_MFR_SPECIFIC command returns 1 byte of information with a summary of the reason for a fault. The STATUS_MFR_SPECIFIC message content is described in Table 24. MAX34441 PMBus 5-Channel Power-Supply Manager and Intelligent Fan Controller READ_FAN_SPEED_1 (90h) The READ_FAN_SPEED_1 command returns the fan speed in RPM. READ_FAN_SPEED_1 is updated once a second, even if the fan is disabled. The PULSE bits in FAN_CONFIG_1_2 must be properly configured to receive the correct fan speed. Fan speeds below 60 RPM (360 RPM for dual mode fans) are reported as 0 RPM. The 2 data bytes are in DIRECT format. PMBUS_REVISION (98h) The PMBUS_REVISION command returns the revision of the PMBus specification to which the device is compliant. The command has 1 data byte. Bits [7:4] indicate the revision of PMBus specification Part I to which the device is compliant. Bits [3:0] indicate the revision of PMBus specification Part II to which the device is compliant. This command is read-only. The PMBUS_REVISION value returned is always 11h, which indicates that it is compliant with Part I Rev 1.1 and Part II Rev 1.1. MFR_ID (99h) The MFR_ID command returns the text (ISO/IEC 8859-1) character of the manufacturer’s (Maxim) identification. The default MFR_ID value is 4Dh (M). This command is read-only. MFR_MODEL (9Ah) The MFR_MODEL command returns the text (ISO/IEC 8859-1) character of the device model number. The default MFR_MODEL value is 52h (R). This command is read-only. MFR_REVISION (9Bh) The MFR_REVISION command returns two text (ISO/IEC 8859-1) characters that contain the device revision numbers for hardware (upper byte) and firmware (lower byte). The default MFR_REVISION value is 3030h (00). This command is read-only. MFR_LOCATION (9Ch) The MFR_LOCATION command loads the device with text (ISO/IEC 8859-1) characters that identify the facility that manufactures the power supply. The maximum number of characters is 8. This data is written to internal flash using the STORE_DEFAULT_ALL command. The factory default text string value is 3130313031303130h. MFR_DATE (9Dh) The MFR_DATE command loads the device with text (ISO/IEC 8859-1) characters that identify the date of manufacture of the power supply. The maximum number of characters is 8. This data is written to internal flash using the STORE_DEFAULT_ALL command. The factory default text string value is 3130313031303130h. MFR_SERIAL (9Eh) The MFR_SERIAL command loads the device with text (ISO/IEC 8859-1) characters that uniquely identify the device. The maximum number of characters is 8. This data is written to internal flash using the STORE_DEFAULT_ALL command. The factory default text string value is 3130313031303130h. 38 PMBus 5-Channel Power-Supply Manager and Intelligent Fan Controller Table 26. MFR_MODE BIT BIT NAME MEANING FORCE_NV_FAULT_LOG Setting this bit to 1 forces the device to log data into the nonvolatile fault log. Once set, the device clears this bit when the action is completed. The host must set again for subsequent action. If an error occurs during this action, the device sets the CML bit in STATUS_BYTE and STATUS_WORD; no bits are set in STATUS_CML. 14 CLEAR_NV_FAULT_LOG Setting this bit to 1 forces the device to clear the nonvolatile fault log by writing FFh to all byte locations. Once set, the device clears this bit when the action is completed. The host must set again for subsequent action. If an error occurs during this action, the device sets the CML bit in STATUS_BYTE and STATUS_WORD; no bits are set in STATUS_CML. 13 ALERT 15 12 0 11 SOFT_RESET 10:9 PGTIME[1:0] 8 PG_SELECT 7 PSEN_PP_OD 6 PSEN_HI_LO 5:0 0 0 = ALERT disabled (device does not respond to ARA). 1 = ALERT enabled (device responds to ARA and ARA must be used). This bit always returns a 0. This bit must be set, then cleared and set again within 8ms for a soft reset to occur. PGTIME1 PGTIME0 TIME FROM POWER GOOD DETERMINED UNTIL PG OUTPUT IS ASSERTED (ms) 0 0 Immediately 0 1 100 1 0 500 1 1 1000 0 = PG/TACHSEL output is power-good indication. 1 = PG/TACHSEL output is TACHSEL (for dual tachometer fans). For dual tachometer fans, this output is toggled every 500ms. Applies to all PSEN outputs. 0 = PSEN push-pull output. 1 = PSEN open-drain output. Applies to all PSEN outputs. 0 = PSEN active low. 1 = PSEN active high. These bits always return a 0. Note: If a dual tachometer fan is used, it is recommended that the slower tachometer signal be presented to the TACH pin when TACHSEL = 0. 39 MAX34441 MFR_MODE (D1h) The MFR_MODE command is used to configure the device to support manufacturer specific commands. The MFR_ MODE command is described in Table 26. MAX34441 PMBus 5-Channel Power-Supply Manager and Intelligent Fan Controller MFR_VOUT_PEAK (D4h) The MFR_VOUT_PEAK command returns the maximum actual measured output voltage. To reset this value to 0, write to this command with a data value of 0. Any values written to this command are used as a comparison for future peak updates. The 2 data bytes are in DIRECT format. MFR_IOUT_PEAK (D5h) The MFR_IOUT_PEAK command returns the maximum measured current. To reset this value to 0, write to this command with a data value of 0. Any values written to this command are used as a comparison for future peak updates. The 2 data bytes are in DIRECT format. MFR_TEMPERATURE_PEAK (D6h) The MFR_TEMPERATURE_PEAK command returns the maximum measured temperature. To reset this value to its lowest value, write to this command with a data value of 8000h. Any other values written by this command are used as a comparison for future peak updates. The 2 data bytes are in DIRECT format. MFR_VOUT_MIN (D7h) The MFR_VOUT_MIN command returns the minimum actual measured output voltage. To reset this value, write to this command with a data value of 7FFFh. Any values written to this command are used as a comparison for future minimum updates. The 2 data bytes are in DIRECT format. MFR_FAULT_RESPONSE (D9h) The MFR_FAULT_RESPONSE command specifies the response to each fault condition supported by the device. In response to a fault, the device always report the fault in the appropriate status register and asserts the ALERT output (if enabled in MFR_MODE). A CML fault cannot cause any device action other than setting the status bit and asserting the ALERT output. The MFR_FAULT_RESPONSE command is described in Table 27. Table 27. MFR_FAULT_RESPONSE BIT BIT NAME 15 NV_LOG 0 = Do not log the fault into MFR_NV_FAULT_LOG. 1 = Log the fault into MFR_NV_FAULT_LOG. 14 GLOBAL 0 = Affect only the selected page power supply. 1 = Affect all supplies with GLOBAL = 1. 13:12 0 MEANING These bits always return a 0. 11:10 MFR_FAN_FAULT_LIMIT_RESPONSE[1:0] See Table 26. 9:8 IOUT_OC_FAULT_LIMIT_RESPONSE[1:0] See Table 26. 7:6 5:4 OT_FAULT_LIMIT_RESPONSE[1:0] See Table 26 (see Note 1). TON_MAX_FAULT_LIMIT_RESPONSE[1:0] See Table 26. 3:2 VOUT_UV_FAULT_LIMIT_RESPONSE[1:0] See Table 26. 1:0 VOUT_OV_FAULT_LIMIT_RESPONSE[1:0] See Table 26. Note 1: All enabled temperature sensor faults are logically ORed together. Note 2: Temperature and fan faults affect all enabled power supplies. Supplies that are designated as global all respond in the same manner. This response is the worst-case response of the global channels for the given fault. Supplies that are not global respond to a temperature or fan fault based upon the programmed response for the particular supply. Note 3: The fault response for a power-supply fault is determined by the programmed fault response for the faulting channel. If this channel is part of a global group, this fault response is performed for all the global channels. 40 PMBus 5-Channel Power-Supply Manager and Intelligent Fan Controller RESPONSE [1:0] 11 FAULT RESPONSE • • • Set the corresponding fault bit in the appropriate status register. Log fault into MFR_NV_FAULT_LOG if NV_LOG = 1. Continue power-supply operation. • Shut down the power supply by deasserting the PSEN output. Wait for the time configured in MFR_FAULT_RETRY and restart the supply. If GLOBAL = 1, all enabled power supplies with GLOBAL = 1 are shut down in sequence as configured with TOFF_DELAY, or they are all shut down immediately as configured by bit 0 in ON_OFF_CONFIG. Wait for the time configured in MFR_FAULT_RETRY and restart supplies in sequence as configured with TON_DELAY. If GLOBAL = 1, assert the FAULT output until faults on all GLOBAL supplies clear and MFR_FAULT_RETRY expires. Set the corresponding fault bit in the appropriate status register. Log fault into MFR_NV_FAULT_LOG if NV_LOG = 1. 10 • • • • 01 00 • • • Latch-off the power supply by deasserting the PSEN output. If GLOBAL = 1, all enabled power supplies with GLOBAL = 1 are either shut down in sequence as configured with TOFF_DELAY, or they are all shut down immediately as configured by bit 0 in ON_OFF_CONFIG. Assert the FAULT output if GLOBAL = 1 until power supplies are restarted by the user. Set the corresponding fault bit in the appropriate status register. Log fault into MFR_NV_FAULT_LOG if NV_LOG = 1. • • Set the corresponding fault bit in the appropriate status register. Continue power-supply operation. Note: ALERT is asserted if enabled when a new status bit is set. A status bit is latched the first time a particular fault or warning occurs. MFR_FAULT_RETRY (DAh) The MFR_FAULT_RETRY command sets the delay time between a power supply being shut down by a fault response and the power supply restarting. This command sets the retry time delay in multiples of 1ms. This command value is used for all fault responses that require delay retry. If global supplies are being sequenced off, the retry delay time does not begin until the last global channel is turned off. The 2 data bytes are in DIRECT format. When MFR_FAULT_RETRY = 0000h, the device restarts the power supply at the next available time period. MFR_NV_FAULT_LOG (DCh) Each time the MFR_NV_FAULT_LOG command is executed, the device returns a block of 255 bytes containing one of the 15 nonvolatile fault logs. The MFR_NV_FAULT_LOG command must be executed 15 times to dump the complete nonvolatile fault log. If the returned fault log is all FFs, this indicates that this fault log has not been written by the device. As the device is operating, it is reading the latest operating conditions for voltage, current, temperature, and fan speed, and it is updating the status registers. All this information is stored in on-board RAM. When a fault is detected (if so enabled in MFR_FAULT_RESPONSE), the device automatically logs this information to one of the 15 nonvolatile fault logs. After 15 faults have been written, bit 0 of STATUS_CML is set and the host must clear the fault log by setting the CLEAR_NV_FAULT_LOG bit in MFR_MODE before any additional faults are logged. All the latest status information is logged as well as eight readings of voltage from the last 800ms in 100ms increments and four readings of current from the last 800ms of operation. If a power supply is not enabled to measure either current or voltage or if a temperature sensor is disabled, the associated fault log position returns 0000h. There is a FAULT_LOG_COUNT (16-bit counter) at the beginning of each fault log that indicates which fault log is the latest. This counter rolls over should more than 65,535 faults be logged. This counter is not cleared when the CLEAR_NV_FAULT_LOG bit in MFR_MODE is toggled. The 255 bytes returned by the MFR_NV_FAULT_LOG command are described in Table 29. 41 MAX34441 Table 28. MFR_FAULT_RESPONSE Codes MAX34441 PMBus 5-Channel Power-Supply Manager and Intelligent Fan Controller EACH FAULT IS WRITTEN INTO THE NEXT FAULT LOG FLASH EACH COMMAND READ ACCESSES THE NEXT FAULT LOG FAULT LOG INDEX 0 (255 BYTES) RAM FAULT LOG INDEX 1 (255 BYTES) STATUS VOLTAGE CURRENT TEMPERATURE FAN SPEED FAULT OCCURENCE MFR_NV_FAULT_LOG FAULT LOG INDEX 2 (255 BYTES) FAULT LOG INDEX 14 (255 BYTES) Figure 5. MFR_NV_FAULT_LOG If an error occurs while the device is attempting to write or clear the NV_FAULT_LOG, the device sets the CML bit in STATUS_BYTE and STATUS_WORD; no bits are set in STATUS_CML. ALERT is asserted (if enabled in MFR_MODE). See Figure 5. USER NOTE: VDD must be above 2.9V for the device to clear or log data into MFR_NV_FAULT_LOG. Table 29. MFR_NV_FAULT_LOG BYTE 0 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40 42 PARAMETER 00h/FAULT_LOG_INDEX FAULT_LOG_COUNT MFR_TIME_COUNT (LSW) MFR_TIME_COUNT (MSW) STATUS_BYTE/STATUS_CML STATUS_WORD STATUS_VOUT Pages 0/1 STATUS_VOUT Pages 2/3 STATUS_VOUT Page 4/00h STATUS_MFR_SPECIFIC Pages 0/1 STATUS_MFR_SPECIFIC Pages 2/3 STATUS_MFR_SPECIFIC Pages 4/00h STATUS_MFR_SPECIFIC Pages 6/7 STATUS_MFR_SPECIFIC Pages 8/9 STATUS_MFR_SPECIFIC Pages 10/11 RESERVED (0000h) STATUS_FANS_1_2/00h MFR_VOUT_PEAK Page 0 MFR_VOUT_PEAK Page 1 MFR_VOUT_PEAK Page 2 MFR_VOUT_PEAK Page 3 BYTE 128 130 132 134 136 138 140 142 144 146 148 150 152 154 156 158 160 162 164 166 168 PARAMETER READ_VOUT Index = 3, Page 2 READ_VOUT Index = 3, Page 3 READ_VOUT Index = 3, Page 4 RESERVED (0000h) READ_VOUT Index = 4, Page 0 READ_VOUT Index = 4, Page 1 READ_VOUT Index = 4, Page 2 READ_VOUT Index = 4, Page 3 READ_VOUT Index = 4, Page 4 RESERVED (0000h) READ_VOUT Index = 5, Page 0 READ_VOUT Index = 5, Page 1 READ_VOUT Index = 5, Page 2 READ_VOUT Index = 5, Page 3 READ_VOUT Index = 5, Page 4 RESERVED (0000h) READ_VOUT Index = 6, Page 0 READ_VOUT Index = 6, Page 1 READ_VOUT Index = 6, Page 2 READ_VOUT Index = 6, Page 3 READ_VOUT Index = 6, Page 4 PMBus 5-Channel Power-Supply Manager and Intelligent Fan Controller BYTE 42 44 46 48 50 52 54 56 58 60 62 64 66 68 70 72 74 76 78 80 82 84 86 88 90 92 94 96 98 100 102 104 106 108 110 112 114 116 118 120 122 124 126 PARAMETER MFR_VOUT_PEAK Page 4 RESERVED (0000h) MFR_IOUT_PEAK Page 0 MFR_IOUT_PEAK Page 1 MFR_IOUT_PEAK Page 2 MFR_IOUT_PEAK Page 3 MFR_IOUT_PEAK Page 4 RESERVED (0000h) MFR_TEMPERATURE_PEAK Page MFR_TEMPERATURE_PEAK Page MFR_TEMPERATURE_PEAK Page MFR_TEMPERATURE_PEAK Page MFR_TEMPERATURE_PEAK Page MFR_TEMPERATURE_PEAK Page MFR_VOUT_MIN Page 0 MFR_VOUT_MIN Page 1 MFR_VOUT_MIN Page 2 MFR_VOUT_MIN Page 3 MFR_VOUT_MIN Page 4 RESERVED (0000h) RESERVED (0000h) RESERVED (0000h) VOLTAGE_INDEX/00h READ_VOUT Index = 0, Page 0 READ_VOUT Index = 0, Page 1 READ_VOUT Index = 0, Page 2 READ_VOUT Index = 0, Page 3 READ_VOUT Index = 0, Page 4 RESERVED (0000h) READ_VOUT Index = 1, Page 0 READ_VOUT Index = 1, Page 1 READ_VOUT Index = 1, Page 2 READ_VOUT Index = 1, Page 3 READ_VOUT Index = 1, Page 4 RESERVED (0000h) READ_VOUT Index = 2, Page 0 READ_VOUT Index = 2, Page 1 READ_VOUT Index = 2, Page 2 READ_VOUT Index = 2, Page 3 READ_VOUT Index = 2, Page 4 RESERVED (0000h) READ_VOUT Index = 3, Page 0 READ_VOUT Index = 3, Page 1 6 7 8 9 10 11 BYTE 170 172 174 176 178 180 182 184 186 188 190 192 194 196 198 200 202 204 206 208 210 212 214 216 218 220 222 224 226 228 230 232 234 236 238 240 242 244 246 248 250 252 254 MAX34441 Table 29. MFR_NV_FAULT_LOG (continued) PARAMETER RESERVED (0000h) READ_VOUT Index = 7, Page 0 READ_VOUT Index = 7, Page 1 READ_VOUT Index = 7, Page 2 READ_VOUT Index = 7, Page 3 READ_VOUT Index = 7, Page 4 RESERVED (0000h) RESERVED (0000h) CURRENT_INDEX/00h READ_IOUT Index = 0, Page 0 READ_IOUT Index = 0, Page 1 READ_IOUT Index = 0, Page 2 READ_IOUT Index = 0, Page 3 READ_IOUT Index = 0, Page 4 RESERVED (0000h) READ_IOUT Index = 1, Page 0 READ_IOUT Index = 1, Page 1 READ_IOUT Index = 1, Page 2 READ_IOUT Index = 1, Page 3 READ_IOUT Index = 1, Page 4 RESERVED (0000h) READ_IOUT Index = 2, Page 0 READ_IOUT Index = 2, Page 1 READ_IOUT Index = 2, Page 2 READ_IOUT Index = 2, Page 3 READ_IOUT Index = 2, Page 4 RESERVED (0000h) READ_IOUT Index = 3, Page 0 READ_IOUT Index = 3, Page 1 READ_IOUT Index = 3, Page 2 READ_IOUT Index = 3, Page 3 READ_IOUT Index = 3, Page 4 RESERVED (0000h) RESERVED (0000h) READ_TEMPERATURE_1 Page 6 READ_TEMPERATURE_1 Page 7 READ_TEMPERATURE_1 Page 8 READ_TEMPERATURE_1 Page 9 READ_TEMPERATURE_1 Page 10 READ_TEMPERATURE_1 Page 11 READ_FAN_SPEED_1 MFR_READ_FAN_PWM LOG_VALID (see note) Note: LOG_VALID is set to DDh if the fault log contains valid data. 43 MAX34441 PMBus 5-Channel Power-Supply Manager and Intelligent Fan Controller MFR_TIME_COUNT (DDh) The MFR_TIME_COUNT command returns the number of seconds the device has been operating since the last time power was applied to the device, RST was toggled, or a soft reset occurred. The counter is a 32-bit value and cannot be reset by the user. MFR_MARGIN_CONFIG (E0h) The MFR_MARGIN_CONFIG command configures the digital PWM outputs to margin the power supplies. The MFR_MARGIN_CONFIG command is described in Table 30. Power-supply margining is implemented using the PWM outputs. The PWM frequency is 62.5kHz. The device close-loop controls the duty cycle to margin the power supply. The device provides 6 bits of duty-cycle resolution. The device margins the power supplies when OPERATION is set to one of the margin states. Margining of the supplies does not begin until all enabled power supplies have exceeded their programmed POWER_GOOD_ON levels. When this happens, the PWM output is enabled and the seed value from MFR_MARGIN_CONFIG is loaded as the initial PWM duty cycle. The device then averages eight samples of VOUT for a total time of 40ms. If the measured VOUT and the target (set by either VOUT_MARGIN_HIGH or VOUT_MARGIN_LOW) differ by more than 1%, the PWM duty cycle is adjusted by one step. The direction of the duty cycle adjustment is determined by the SLOPE bit in MFR_MARGIN_CONFIG. All changes to the PWM are made after averaging eight samples of VOUT over a 40ms period. The device is unable to successfully margin a power supply to the programmed target when the PWM duty cycle reaches 0% or 100% and the target voltage has not been achieved. If this occurs, the device continues attempting to margin the power supply and does the following: 1) Sets the NONE OF THE ABOVE bit in STATUS_BYTE. 2) Sets the NONE OF THE ABOVE and MFR bits in STATUS_WORD. 3) Sets the MARGIN_FAULT bit in STATUS_MFR_SPECIFIC. 4) Notifies the host through ALERT assertion (if enabled in MFR_MODE). Also, the averaged VOUT after the PWM has initially been enabled with the seed value is compared to the target value. If the programmed seed value causes VOUT to exceed the target, a MARGIN_FAULT is declared. For example, if the target is VOUT_MARGIN_LOW and VOUT is less than VOUT_MARGIN_LOW after seeding, MARGIN_FAULT is set. In response to this fault, the device continues margining the power supply and does the following: 1) Sets the NONE OF THE ABOVE bit in STATUS_BYTE. 2) Sets the NONE OF THE ABOVE and MFR bits in STATUS_WORD. 3) Sets the MARGIN_FAULT bit in STATUS_MFR_SPECIFIC. 4) Notifies the host through ALERT assertion (if enabled in MFR_MODE). Table 30. MFR_MARGIN_CONFIG 44 BIT BIT NAME 15 SLOPE 14:6 0 5:0 SEED MEANING PWM duty cycle to resulting voltage relationship. 0 = Negative slope (increasing duty cycle results in a lower voltage). 1 = Positive slope (increasing duty cycle results in a higher voltage). These bits always return a 0. This 6-bit value is used as the initial PWM duty cycle (i.e., seed value) when the device begins to margin a power supply either up or down. PMBus 5-Channel Power-Supply Manager and Intelligent Fan Controller Table 31. MFR_TEMP_SENSOR_CONFIG BIT 15 BIT NAME ENABLE MEANING 0 = Temperature sensor disabled. 1 = Temperature sensor enabled. The OFFSET setting is used to allow the temperature reading to be normalized among multiple temperature sensors. Values from 00h to 1Eh select the offset value. The valid range is 0NC to +30NC in 1NC steps. If OFFSET is 1Fh, the device automatically uses the value written to the OT_WARN_LIMIT command code for the LUT instead of the digitized measured temperature. OFFSET VALUE 14:10 OFFSET 9:1 0 0 FAN CONFIGURATION 00h Offset = 0NC 01h Offset = +1NC 02h Offset = +2NC 1Dh Offset = +29NC 1Eh Offset = +30NC 1Fh Test Mode These bits always return a 0. 0 = Temperature sensor is not used to control fan speed. 1 = Temperature sensor is used to control fan speed. 45 MAX34441 MFR_TEMP_SENSOR_CONFIG (F0h) The MFR_TEMP_SENSOR_CONFIG command is used to configure the temperature sensors. Table 31 describes the MFR_TEMP_SENSOR_CONFIG command. MAX34441 PMBus 5-Channel Power-Supply Manager and Intelligent Fan Controller MFR_FAN_CONFIG (F1h) The MFR_FAN_CONFIG command is used with FAN_CONFIG_1_2 to configure the fan. See the FAN_CONFIG_1_2 description for more details on this command. Table 32 described the MFR_FAN_CONFIG command. Table 32. MFR_FAN_CONFIG BIT BIT NAME MEANING The FREQ bits set the PWM frequency. Note: The device does not support pulse stretching. 15:13 12 FREQ[2:0] 0 FREQ2 FREQ1 FREQ0 PWM FREQUENCY 0 0 0 30Hz 0 0 1 50Hz 0 1 0 100Hz 0 1 1 150Hz 1 0 0 Reserved 1 0 1 Reserved 1 1 0 Reserved 1 1 1 25kHz This bit always returns a 0. The HYS bits determine the amount of hysteresis the device uses to determine how far the temperature must fall below the temperature level threshold programmed in the LUT before switching to the lower PWM/RPM value. The hysteresis should be set lower than the minimum difference between two adjacent temperature steps. These bits are ignored if automatic fan control is disabled. 11:10 9 8 46 HYS[1:0] TSFO TACHO HSY1 HSY0 THERMAL HYSTERESIS (NC) 0 0 2 0 1 4 1 0 6 1 1 8 0 = Ramp to 100% PWM duty cycle if temp sensor faults (automatic fan mode) or if no FAN_COMMAND_1 update occurs (manual fan mode) in any 10s period. 1 = Temp sensor fault or update rate to FAN_COMMAND_1 is ignored. Operate at the last updated PWM/RPM value. Note 1: A temp sensor fault is a faulty temperature sensor reading, not an overtemperature fault. Note 2: In automatic fan mode, if the TSFO bit is set to 1, the device ignores a sensor fault and uses the remaining assigned temperature sensors (if any) to control the fan PWM duty cycle; or, if the fan has no available temperature sensors to use, it maintains the last updated PWM/RPM fan value before the fault occurred. 0 = Ramp fan to 100% PWM duty cycle if fan fault is detected. 1 = Do not ramp fan to 100% PWM duty cycle if fan fault is detected. Note: If the fan fault is removed after ramping the PWM to 100% duty cycle, normal fan operation is resumed. PMBus 5-Channel Power-Supply Manager and Intelligent Fan Controller BIT BIT NAME MEANING The RAMP bits select how fast the device ramps the PWM from one duty cycle to another (either up or down). In PWM mode, the following table always applies. In RPM mode, the fan speed is read either every 200ms or 1000ms and when the reported fan speed is within 20% of the target speed, the maximum allowed PWM duty cycle change is set to 1%. In RPM mode, the PWM duty cycle is not changed as long as the fan is within Q5% of the target speed. 7:5 4 3 RAMP[2:0] 0 ROTOR_HI_LO TIME TO RAMP MAX PWM DUTY FROM 40% TO CYCLE CHANGE 100% PWM DUTY ALLOWED (%) CYCLE (seconds) RAMP2 RAMP1 RAMP0 PWM DUTY CYCLE UPDATE RATE (ms) 0 0 0 1000 1 60 0 0 1 1000 2 30 0 1 0 1000 3 20 0 1 1 200 1 12 1 0 0 200 2 6 1 0 1 200 3 4 1 1 0 200 4 3 1 1 1 200 5 2.4 This bit always returns a 0. Determines if a locked rotor indication is active low or active high. This bit is ignored if ROTOR = 0. 0 = ROTOR is active low (TACH input is low if the rotor stops). 1 = ROTOR is active high (TACH input is high if the rotor stops). The ROTOR bit selects if the fan does not have a tachometer but rather a stalled (or locked) rotor output. 2 1:0 ROTOR SPIN[1:0] ROTOR FAN OUTPUT 0 Tachometer 1 Stalled/locked rotor detect MAX34441 CONFIGURATION TACH input expects fan RPM TACH input expects locked rotor signal. The polarity is selected with the ROTOR_HI_LO bit (also set MFR_FAN_FAULT_LIMIT = 0001h). The SPIN bits determine how the device spins up (or starts) the fan from a dead stop. To overcome the initial mechanical fan inertia, the device can be programmed to drive the fan at 100% duty cycle until a programmable number of fan revolutions (cumulative count) is detected or a locked rotor signal is negated. The device allows a 2s startup period during which the fan speed monitors are disabled. If after 2s the fan does not respond, the PWM output remains at 100% duty cycle (if TACHO = 0) or goes to 0% duty cycle (if TACHO = 1). SPIN1 SPIN0 0 0 Automatic spin-up disabled SPIN-UP RELAXATION CRITERIA 0 1 Two revolutions or locked rotor negated 1 0 Four revolutions or locked rotor negated 1 1 Eight revolutions or locked rotor negated Note: It is recommended that the fan be disabled prior to changing MFR_FAN_CONFIG. 47 MAX34441 Table 32. MFR_FAN_CONFIG (continued) MAX34441 PMBus 5-Channel Power-Supply Manager and Intelligent Fan Controller MFR_FAN_LUT (F2h) The MFR_FAN_LUT command is used to configure the LUT that controls the fan. The fan has an LUT that maps eight programmable temperature levels to eight programmable fan PWM duty-cycle levels (bit 6 in FAN_CONFIG_1_2 is zero) or eight programmable target fan speeds (bit 6 in FAN_CONFIG_1_2 is one). The LUT allows a wide variety of profiles to be used. USER NOTE: The programmable configuration of MFR_FAN_LUT must be monotonic. Table 33. MFR_FAN_LUT BYTE NUMBER WORD NAME 0-1 TEMP STEP 0 Temperature for step 0. MEANING 2-3 SPEED STEP 0 Fan PWM duty cycle or fan speed for step 0. 4-5 TEMP STEP 1 Temperature for step 1. 6-7 SPEED STEP 1 Fan PWM duty cycle or fan speed for step 1. 8-9 TEMP STEP 2 Temperature for step 2. 10-11 SPEED STEP 2 Fan PWM duty cycle or fan speed for step 2. 12-13 TEMP STEP 3 Temperature for step 3. 14-15 SPEED STEP 3 Fan PWM duty cycle or fan speed for step 3. 16-17 TEMP STEP 4 Temperature for step 4. 18-19 SPEED STEP 4 Fan PWM duty cycle or fan speed for step 4. 20-21 TEMP STEP 5 Temperature for step 5. 22-23 SPEED STEP 5 Fan PWM duty cycle or fan speed for step 5. 24-25 TEMP STEP 6 Temperature for step 6. 26-27 SPEED STEP 6 Fan PWM duty cycle or fan speed for step 6. 28-29 TEMP STEP 7 Temperature for step 7. 30-31 SPEED STEP 7 Fan PWM duty cycle or fan speed for step 7. TEMPERATURE STEP: Temperature Level Setting The TEMPERATURE STEP sets the temperature in degrees Celsius and represents a threshold level at which the device updates the fan PWM duty cycle setting. The 2 data bytes are in DIRECT format. The valid temperature range depends on the temperature sensor. Table 34. Valid Temperature Range TEMPERATURE SENSOR VALID RANGE Page 6: Internal Temp Sensor -40NC to +85NC Pages 7 to 10: I2C Remote Temp Sensor -55NC to +125NC Page 11: Remote Thermal Diode Temp Sensor -40NC to +120NC 48 PMBus 5-Channel Power-Supply Manager and Intelligent Fan Controller If bit 6 in FAN_CONFIG_1_2 is set to 1, the FAN SPEED STEP sets the fan target speed (in RPM) at each temperature step breakpoint. The valid fan speed range is 0 to 32,767 (inclusive). THERMAL HYSTERESIS MAXIMUM DESIRED FAN DUTY CYCLE OR SPEED S7 S6 S5 S4 FAN PWM DUTY CYCLE OR FAN SPEED (IN RPM) S3 S2 S1 S0 PWM = 0% DUTY CYCLE T0 T1 T2 T3 T4 T5 T6 T7 NORMALIZED TEMPERATURE (FROM ONE OR MORE TEMP SENSORS) Figure 6. Fan Lookup Table (LUT) Format 49 MAX34441 FAN SPEED STEP: Fan PWM Duty Cycle or Fan Speed Setting If bit 6 in FAN_CONFIG_1_2 is set to zero, the FAN SPEED STEP sets the fan PWM duty cycle at each temperature step breakpoint. The valid duty cycle range is 0 to 100 (inclusive). Any values greater than 100 (decimal) result in 100% PWM duty cycle being generated, and any values less than 0 (decimal) result in 0% PWM duty cycle. MAX34441 PMBus 5-Channel Power-Supply Manager and Intelligent Fan Controller MFR_READ_FAN_PWM (F3h) The MFR_READ_FAN_PWM command returns the latest real-time value for the fan PWM in % duty cycle. MFR_READ_FAN_PWM is updated whenever the PWM duty cycle is updated. This is determined by the RATE bits in MFR_FAN_CONFIG. The 2 data bytes are in DIRECT format. MFR_FAN_FAULT_LIMIT (F5h) The MFR_FAN_FAULT_LIMIT command sets the value of the fan speed (in RPM) or percentage of target fan speed that causes a fan fault. Fans operating below these limits for over 10s continuous trip the fault. When the fan is operating in RPM mode, the 10s checking period starts after the device has completed a PWM ramp of the fan speed. The slowest tachometer signal the device can measure for a fan is 60 RPM. In dual tachometer applications, the slowest RPM is 360. Tachometer signals slower than these minimums are reported as 0 RPM. Fault and warning limits should be set to RPM values greater than these minimum RPM limits. The 2 data bytes are in DIRECT format. Set to 0000h to disable the limit checking. Set to 0001h to only alarm when the tachometer input is locked for greater than 10s (this mode should be used when the fan only has a locked rotor output). In response to violation of the MFR_FAN_FAULT_LIMIT or if a stalled/locked rotor is detected, the device does the following: 1) Sets the NONE OF THE ABOVE bit in STATUS_BYTE. 2) Sets the NONE OF THE ABOVE and FANS bits in STATUS_WORD. 3) Sets the FAN_1_FAULT bit in STATUS_FANS_1_2. 4) Responds as specified in the MFR_FAULT_RESPONSE. 5) Notifies the host using ALERT assertion (if enabled in MFR_MODE). USER NOTE: For proper fan operation, MFR_FAN_FAULT_LIMIT must be configured. MFR_FAN_WARN_LIMIT (F6h) The MFR_FAN_WARN_LIMIT command sets the value of the fan speed (in RPM) or percentage of target fan speed that causes a fan speed warning. Fans operating below these limits for over 10s continuous trip the warning. When the fan is operating in RPM mode, the 10s checking period starts after the device has completed a PWM ramp of the fan speed. Normally, the MFR_FAN_WARN_LIMIT is set higher than the MFR_FAN_FAULT_LIMIT. The 2 data bytes are in DIRECT format. Set to 0000h to disable the limit checking. Set to 0001h to generate a warning when using a locked rotor fan. In response to violation of the MFR_FAN_WARN_LIMIT, the device does the following: 1) Sets the NONE OF THE ABOVE bit in STATUS_BYTE. 2) Sets the NONE OF THE ABOVE bit in STATUS_WORD. 3) Sets the FAN_1_WARN bit in STATUS_FANS_1_2. 4) Notifies the host using ALERT assertion (if enabled in MFR_MODE). Table 35. Monitored Fan Fault and Warning Parameters FAN CONTROL MODE 50 LIMIT PARAMETER COMPARISON INTERVAL Manual PWM Fan speed (in RPM) Checked once a second Manual RPM Percentage of programmed target fan speed Checked once a second Automatic PWM Fan speed (in RPM) Checked once a second Automatic RPM Percentage of LUT target fan speed Checked once a second PMBus 5-Channel Power-Supply Manager and Intelligent Fan Controller Power-Supply Decoupling To achieve the best results when using the device, decouple the VDD power supply with a 0.1FF capacitor. Use a high-quality, ceramic, surface-mount capacitor if possible. Surface-mount components minimize lead inductance, which improves performance, and ceramic capacitors tend to have adequate high-frequency response for decoupling applications. Open-Drain Pins MSDA, MSCL, SCL, SDA, FAULT, and ALERT are opendrain pins and require external pullup resistors connected to VDD to realize high logic levels. PSEN0 to PSEN4 can be user-configured as either CMOS push-pull or open-drain outputs. When configured as open-drain, external pullup resistors connected to VDD are required to realize high logic levels (see the MFR_MODE settings). Decouple the REG25 and REG18 regulator outputs using 1FF and 10nF capacitors (one each per output). 51 MAX34441 Applications Information PMBus 5-Channel Power-Supply Manager and Intelligent Fan Controller MAX34441 Typical Operating Circuit INPUT VOLTAGE IN OUT POWER SUPPLY MAX9938 CURRENT-SENSE AMPLIFIER TRIM EN UP TO 4 CHANNELS MSCL +3.3V VSS SDA SCL OPTIONAL SUPPORT FOR CURRENT MONITORING FROM MUXSEL PSEN1 PWM1 RS-1 RS+1 VDD HOST INTERFACE SPDT MUX 5 CHANNELS PSEN0 PWM0 RS-0 RS+0 MSDA DS75LV I2C TEMP SENSOR LOAD MAX34441 RST ALERT FAULT A0/MUXSEL A1/PG/TACHSEL PSEN2 PWM2 RS-2 RS+2 PSEN3 PWM3 RS-3 RS+3 PSEN4 PWM4 RS-4 RS+4 REG25 RS+5 REG18 RS-5 PWM5 TACH5 REMOTE TEMPERATURE DIODE OPTIONAL SUPPORT FOR DUAL FANS SPDT MUX FROM TACHSEL Package Information For the latest package outline information and land patterns, go to www.maxim-ic.com/packages. Note that a “+”, “#”, or “-” in the package code indicates RoHS status only. Package drawings may show a different suffix character, but the drawing pertains to the package regardless of RoHS status. 52 PACKAGE TYPE PACKAGE CODE OUTLINE NO. LAND PATTERN NO. 40 TQFN-EP T4066+2 21-0141 90-0053 PMBus 5-Channel Power-Supply Manager and Intelligent Fan Controller REVISION NUMBER REVISION DATE 0 8/10 DESCRIPTION Initial release PAGES CHANGED — Maxim cannot assume responsibility for use of any circuitry other than circuitry entirely embodied in a Maxim product. No circuit patent licenses are implied. Maxim reserves the right to change the circuitry and specifications without notice at any time. Maxim Integrated Products, 120 San Gabriel Drive, Sunnyvale, CA 94086 408-737-7600 © 2010 Maxim Integrated Products 53 Maxim is a registered trademark of Maxim Integrated Products, Inc. MAX34441 Revision History