CRT Power Supply INTRODUCING OUR NEW CRS110G50 • CRS180G60 CRS ADJUSTABLE SERIES ELECTRICAL RATINGS V0 G2(MAX) kV V CRS110G50 6.0 - 11.0 200-500 CRS180G60 11.0 - 18.0 200-600 Part Number SPECIFICATIONS Input Voltage: +24VDC ± 10% Anode Output Voltage: 6-11kVDC CRS110G50 adjustable 11-18kVDC CRS180G60 adjustable Anode Output Current: 0 to 550µA CRS110G50 Features: • Low ripple • Excellent regulation • Arc and short circuit protection • Adjustable anode voltage 0 to 550µA CRS180G60 Anode Ripple Voltage: < 1% peak to peak Anode Load Regulation: < 0.1% for NL to FL change G2 Output Voltage: 200 to 500VDC CRS110G50 adjustable 200 to 600VDC CRS180G60 adjustable G2 Output Current: 0 to 50µA CRS110G50 0 to 50µA CRS180G60 G2 Ripple Voltage: < 1% peak to peak G2 Regulation: < 0.1% for NL to FL change CRS Series The CRS110G50 & CRS180G60 power supplies provide 11kV and 18kV anode voltages as well as G2 voltage adjustable to 500V & 600V respectively. These supplies feature excellent regulation, low ripple and adjustable anode voltage. Environmental: • Storage Temperature -25°C to +85°C • Operating Temperature 0°C to +50°C Dimensions: In. (mm) • All temperatures are ambient unless otherwise noted. • Data subject to change without notice. VOLTAGE MULTIPLIERS INC. 8711 W. Roosevelt Ave. Visalia, CA 93291 61 TEL. 559-651-1402 FAX 559-651-0740 www.voltagemultipliers.com www.highvoltagepowersupplies.com CRS110G50 CRS180G60 INTERFACE PIN ASSIGNMENT 1 G2 Out 2 +24VDC 3 Factory use only 4 Ground Dimensions: In. (mm) • All temperatures are ambient unless otherwise noted. • Data subject to change without notice. TEL. 559-651-1402 FAX 559-651-0740 www.voltagemultipliers.com www.highvoltagepowersupplies.com VOLTAGE MULTIPLIERS INC. 8711 W. Roosevelt Ave. Visalia, CA 93291 62