LANK 10W Series 2:1 Wide Input Range Single and Dual Output 10 Watt DC/DC Converter FEATURES ● I/O Isolation 1500VDC ● MTBF > 1,000,000 Hours ● Industry Standard Pinout ● High Efficiency up to 88% ● CSA1950 Safety Approval ● 2:1 Wide Input Voltage Range ● Complies with EN55022 Class A ● Short Circuit and Over Voltage Protection SPECIFICATIONS: LANK 10W Series All specifications are based on 25oC, Nominal Input Voltage, and Maximum Output Current unless otherwise noted. We reserve the right to change specifications based on technological advances. SPECIFICATION TEST CONDITIONS Min Nom Max Unit INPUT (Vin) Input Voltage Range Start Voltage Under Voltage Shutdown Input Surge Voltage (1000ms) Reverse Polarity Input Current Reflected Ripple Current Short Circuit Input Power Input Filter OUTPUT (Vo) Output Voltage Range Output Voltage Accuracy Output Voltage Balance Load Regulation Load Regulation (2.5V output only) Line Regulation Output Power Output Current Range Ripple & Noise (20MHz) Ripple & Noise (20MHz) Ripple & Noise (20MHz) Transient Recovery Time Transient Response Deviation Temperature Coefficient PROTECTION Over Power Protection Short Circuit Protection Input Fuse Recommendation GENERAL Efficiency Switching Frequency Isolation Voltage Rated Isolation Voltage Test Isolation Resistance Isolation Capacitance Maximum Capacitive Load Internal Power Dissipation 12V input models 24V input models 48V input models 12V input models 24V input models 48V input models 12V input models 24V input models 48V input models 12V input models 24V input models 48V input models All models 9 18 36 7 14 30 -0.7 -0.7 -0.7 All models All models 12 24 48 8 16 33 18 36 75 9 18 36 8.5 17 34 25 50 100 0.5 See Table 2500 Pi Filter See Table ±0.6 ±1.2 ±0.5 ±2.0 ±0.5 ±1.2 ±0.7 ±1.5 ±0.3 ±1.0 10 See Table 50 85 100 15 250 500 ±3 ±5 ±0.01 ±0.02 Dual Output, Balanced Loads Io = 10% to 100% Io = 10% to 100% Vin = Min to Max Over Line, Load, and Temperature 25% Load Step Change 25% Load Step Change 110 12V input models 24V input models 48V input models 1500 1650 1000 Wall Industries, Inc. 5 Watson Brook Road Exeter, NH 03833 603-778-2300 www.wallindustries.com Fax 603-778-9797 mW % % % % % W mVpk-pk mVpk-pk mVrms µs % %/°C 150 180 % Continuous 2000mA Slow-Blow Type 1000mA Slow-Blow Type 500mA Slow-Blow Type See Table 400 60 seconds Flash Tested for 1 second 500VDC 100KHz, 1V VDC VDC VDC VDC VDC VDC VDC VDC VDC VDC VDC VDC A 1000 1200 See Table 2500 KHz VDC VDC MΩ pF mW LANK 10W Series 2:1 Wide Input Range Single and Dual Output 10 Watt DC/DC Converter SPECIFICATION (CONTINUED) TEST CONDITIONS ENVIRONMENTAL Operating Temperature (Ambient) Operating Temperature (Case) Storage Temperature Lead Temperature Humidity Cooling MTBF PHYSICAL Weight Dimensions Case Material Min -40 -40 -40 1.5mm from case for 10 seconds MIL-HDBK-217F @ 25°C, Ground Benign Nom Max +60 +90 +125 260 95 Free air convection 1,000,000 Hours Unit °C °C °C °C % 17.3 grams 31.8(L) x 20.3(W) x 10.2(H) mm Metal with non-conductive baseplate OUTPUT VOLTAGE / CURRENT RATING CHART Model Number LANK1233W10 LANK1205W10 LANK1251W10 LANK1212W10 LANK1215W10 LANK1212DW10 LANK1215DW10 LANK2425W10 LANK2433W10 LANK2405W10 LANK2451W10 LANK2412W10 LANK2415W10 LANK2412DW10 LANK2415DW10 LANK4825W10 LANK4833W10 LANK4805W10 LANK4851W10 LANK4812W10 LANK4815W10 LANK4812DW10 LANK4815DW10 Input Voltage 12 VDC (9 – 18 VDC) 24 VDC (18 – 36 VDC) 48 VDC (36 – 75 VDC) Output Voltage 3.3 VDC 5 VDC 5.1 VDC 12 VDC 15 VDC ±12 VDC ±15 VDC 2.5 VDC 3.3 VDC 5 VDC 5.1 VDC 12 VDC 15 VDC ±12 VDC ±15 VDC 2.5 VDC 3.3 VDC 5 VDC 5.1 VDC 12 VDC 15 VDC ±12 VDC ±15 VDC Output Current Input Current (Typ) Min Max No Load 300mA 200mA 200mA 83mA 66.6mA ±42mA ±33mA 300mA 300mA 200mA 200mA 83mA 66.6mA ±42mA ±33mA 300mA 300mA 200mA 200mA 83mA 66.6mA ±42mA ±33mA 3000mA 2000mA 2000mA 833mA 666mA ±416mA ±333mA 3000mA 3000mA 2000mA 2000mA 833mA 666mA ±416mA ±333mA 3000mA 3000mA 2000mA 2000mA 833mA 666mA ±416mA ±333mA 40mA 20mA 10mA Max Load 1006mA 1004mA 1024mA 957mA 968mA 957mA 968mA 377mA 485mA 479mA 489mA 479mA 478mA 473mA 478mA 188mA 243mA 239mA 244mA 240mA 239mA 236mA 243mA Reflected Ripple Efficiency Max Capacitive Current (Typ) (Typ) Load 82% 2200µF 83% 2200µF 83% 2200µF 60mA 87% 820µF 86% 470µF 87% 220µF 86% 150µF 83% 2200µF 85% 2200µF 87% 2200µF 87% 2200µF 40mA 87% 820µF 87% 470µF 87% 220µF 87% 150µF 83% 2200µF 85% 2200µF 87% 2200µF 87% 2200µF 40mA 87% 820µF 87% 470µF 87% 220µF 87% 150µF NOTES 1. Specifications typical at +25°C, resistive load, nominal input voltage, rated output current unless otherwise noted. 2. Transient Recovery Time is measured to within 1% error band for a step change in output of 75% to 100%. 3. Ripple and noise measured at 20MHz bandwidth. 4. The LANK 10W Series requires a minimum load on the output to maintain specified regulation. Operation under no-load conditions will not damage these devices, however they may not meet all listed specifications. 5. All DC/DC converters should be externally fused on the front end for protection. 6. Other input and output voltages may be available, please contact factory. 7. Specifications subject to change without notice. Wall Industries, Inc. 5 Watson Brook Road Exeter, NH 03833 603-778-2300 www.wallindustries.com Fax 603-778-9797 LANK 10W Series 2:1 Wide Input Range Single and Dual Output 10 Watt DC/DC Converter BLOCK DIAGRAMS Input Voltage Transient Rating Wall Industries, Inc. 5 Watson Brook Road Exeter, NH 03833 603-778-2300 www.wallindustries.com Fax 603-778-9797 LANK 10W Series 2:1 Wide Input Range Single and Dual Output 10 Watt DC/DC Converter MECHANICAL DRAWING Connecting Pin Patterns Top View (2.54mm/0.1 inch grids) Tolerance: Pin: Millimeters X.X±0.25 X.XX±0.13 ±0.05 Inches X.XX±0.01 X.XXX±0.005 ±0.002 PIN CONNECTIONS Pin Single Output Dual Output 2 -Vin -Vin 3 -Vin -Vin 9 No Pin Common 11 NC -Vout 14 +Vout +Vout 16 -Vout Common 22 +Vin +Vin 23 +Vin +Vin Wall Industries, Inc. 5 Watson Brook Road Exeter, NH 03833 603-778-2300 www.wallindustries.com Fax 603-778-9797 LANK 10W Series 2:1 Wide Input Range Single and Dual Output 10 Watt DC/DC Converter DESIGN & FEATURE CONSIDERATONS Input Source Impedance The power module should be connected to a low ac-impedance input source. Highly inductive source impedances can affect the stability of the power module. In applications where power is supplied over long lines and output loading is high, it may be necessary to use a capacitor at the input to ensure startup. By using a good quality low Equivalent Series Resistance (ESR < 1.0Ω at 100kHz) capacitor of 12µF for the 12V input devices, a 4.7µF for the 24V input devices, and a 2.2µF for the 48V input devices. A capacitor mounted close to the power module helps ensure stability of the unit. Maximum Capacitive Load The LANK 10W Series has a limitation of maximum connected capacitance on the output. The power module may operate in current limiting mode during start-up, affecting the ramp-up and the startup time. The maximum capacitance can be found in the “Output Voltage / Current Rating Chart.” Over Current Protection To provide protection in a fault (output overload) condition, the unit is equipped with internal current limiting circuitry and can endure current limiting for an unlimited duration. At the point of current-limit inception, the unit shifts from voltage control to current control. The unit operates normally once the output current is brought back into its specified range. Over Voltage Protection The Output over voltage clamp consists of control circuitry, which is independent of the primary regulation loop that monitors the voltage on the output terminals. The control loop of the clamp has a higher voltage set point than the primary loop. This provides a redundant voltage control that reduces the risk of output over voltage. Thermal Considerations Many conditions affect the thermal performance of the power module, such as orientation, airflow over the module, and board spacing. To avoid exceeding the maximum temperature rating of the components inside the power module, the case temperature must be kept below 95°C. The derating curves are determined from measurements obtained in an experimental apparatus. Wall Industries, Inc. 5 Watson Brook Road Exeter, NH 03833 603-778-2300 www.wallindustries.com Fax 603-778-9797 LANK 10W Series 2:1 Wide Input Range Single and Dual Output 10 Watt DC/DC Converter Efficiency vs Input Voltage ( Single Output ) Efficiency vs Input Voltage ( Dual Output ) Efficiency vs Output Load ( Single Output ) Efficiency vs Output Load ( Dual Output ) Derating Curve Wall Industries, Inc. 5 Watson Brook Road Exeter, NH 03833 603-778-2300 www.wallindustries.com Fax 603-778-9797 LANK 10W Series 2:1 Wide Input Range Single and Dual Output 10 Watt DC/DC Converter TEST CONFIGURATIONS Input Reflected-Ripple Current Test Setup Input reflected-ripple current is measured with an inductor Lin (4.7uH) and Cin (220uF, ESR < 1.0Ω at 100 KHz) to simulate source impedance. Capacitor Cin offsets possible battery impedance. Current ripple is measured at the input terminals of the module. Measurement bandwidth is 0-500 KHz. Peak-to-Peak Output Noise Measurement Test Use a Cout 0.47uF ceramic capacitor. Scope measurement should be made by using a BNC socket, measurement bandwidth is 0-20MHz. Position the load between 50mm and 75mm from the DC/DC Converter. Wall Industries, Inc. 5 Watson Brook Road Exeter, NH 03833 603-778-2300 www.wallindustries.com Fax 603-778-9797 LANK 10W Series 2:1 Wide Input Range Single and Dual Output 10 Watt DC/DC Converter Output Ripple Reduction A good quality low ESR capacitor placed as close as possible across the load will give the best ripple and noise performance. To reduce output ripple, it is recommended to use 3.3uF capacitors at the output. COMPANY INFORMATION: Wall Industries, Inc. has created custom and modified units for over 40 years. Our in-house research and development engineers will provide a solution that exceeds your performance requirements on time and on budget. Our ISO9001-2000 certification is just one example of our commitment to producing a high quality, well documented product for our customers. Our past projects demonstrate our commitment to you, our customer. Wall Industries, Inc. has a reputation for working closely with its customers to ensure each solution meets or exceeds form, fit and function requirements. We will continue to provide ongoing support for your project above and beyond the design and production phases. Give us a call today to discuss your future projects. Contact Wall Industries for further information: Phone: Toll Free: Fax: E-mail: Web: Address: (603)778-2300 (888)587-9255 (603)778-9797 [email protected] www.wallindustries.com 5 Watson Brook Rd. Exeter, NH 03833 Wall Industries, Inc. 5 Watson Brook Road Exeter, NH 03833 603-778-2300 www.wallindustries.com Fax 603-778-9797