Obsolescence Notice This product is obsolete. This information is available for your convenience only. For more information on Zarlink’s obsolete products and replacement product lists, please visit http://products.zarlink.com/obsolete_products/ ZL30462 Compact Timing Module Data Sheet Features January 2005 • Complete timing solution in a small outline package • 8 kHz, 1.544 MHz, 2.048 MHz or 19.44 MHz input reference frequencies • 8 kHz (frame pulse), 2.048 MHz, 8.192 MHz, 16.384 MHz, 19.44 MHz and two 155.52 MHz (LVPECL) output clock frequencies • Low intrinsic jitter and wander generation • Automatic Holdover modes • Holdover and lock indication • Selectable operation modes • Accepts reference inputs from two independent sources • 3.3 V Supply Voltage Ordering Information ZL30462MCF 40 SMTDIL 0°C to +70°C Description The ZL30462 is a Timing Module, which functions as a complete system clock solution for general timing applications. The ZL30462 has been designed around Zarlink's Digital and Analog Phase Locked Loop (DPLL and APLL) technology and can lock to one of two inputs that can be derived from two independent sources. The inputs automatically detect if one of four frequencies is present, 8 kHz, 1.544 MHz, 2.048 MHz or 19.44 MHz. The module has three jitter attenuated output clocks one 19.44 MHz (CMOS) and two 155.52 MHz (LVPECL). In addition to these outputs the module also supplies an 8 kHz frame pulse plus 2.048 MHz, 8.192 MHz and 16.384 MHz clocks. Applications • SDH Add/Drop multiplexers • Next Gen. Digital Loop Carriers • ATM edge switches • Line cards TVdd TGND OSC Vdd AGND M a s te r O s c illa to r /C 1 6 o C8o O u tp u t In te rfa c e C irc u it C2o /F 1 6 o LK1 (1 9 .4 4 M H z ) D PLL PRI SEC R e fe re n c e S e le c t MUX T IE C o rre c to r C irc u it LK2 JA19M o In p u t Im p ra irm e n t M o n ito r RSEL APLL J A 1 5 5 P /N -1 C o n v e rte r J A 1 5 5 P /N -2 C o n tro l S ta te M a c h in e MS1 MS2 /R E S E T /T C L R LO C K H O LD O V E R Figure 1 - Functional Block Diagram 1 Zarlink Semiconductor Inc. Zarlink, ZL and the Zarlink Semiconductor logo are trademarks of Zarlink Semiconductor Inc. Copyright 2003-2005, Zarlink Semiconductor Inc. All Rights Reserved. ZL30462 40 1 1 Data Sheet 20 21 Figure 2 - 40 Pin SMT DIL Top View Pin Description Table Pin Number Name Description 1 C16o Clock 16.384 MHz (CMOS Output). This general purpose output may be used for ST-BUS operation with a 16.384 MHz clock. 2 C8o Clock 8.192 MHz (CMOS Output). This general purpose output may be used for ST-BUS operation at 8.192 Mb/s. 3 C2o Clock 2.048 MHz (CMOS Output). This general purpose output may be used for ST-BUS operation at 2.048 Mb/s. 4 F16o Frame Pulse ST-BUS 16.384 Mb/s (CMOS Output). This is an 8 kHz 61 ns active low framing pulse, which marks the beginning of an ST-BUS frame. This is typically used for ST-BUS operation at 16.384 Mb/s. 5 LK1 (19.44MHz) 6 LK2 7 AGND1 8 NC No Connection. This pin is unused and has no internal connection. 9 NC No Connection. This pin is unused and has no internal connection. 10 AGND1 11 12 JA155N-2 JA155P-2 13 VDD2 Positive Power Supply. 3.3 V 14 LOCK Lock Indicator (CMOS Output). This output goes high when the PLL is frequency locked to the input reference. 15 JA19Mo Link1. Connect this pin to pin 6. This 19.44 MHz signal must not be used for external applications. Link2. Connect this pin to pin 5. Ground. Ground. JA 155-2 Clock (LVPECL Output). This differential output provides a low jitter 155.52 MHz clock. Clock 19.44 MHz (CMOS Output). This output provides a low jitter 19.44 MHz clock. 2 Zarlink Semiconductor Inc. ZL30462 Data Sheet Pin Description Table (continued) Pin Number Name Description 16 17 JA155N-1 JA155P-1 18 AGND2 19 VDD3 20 AGND1 21 TVDD Oscillator Positive Power Supply. 3.3 V 22 TGND Oscillator Ground. 23 OSC Oscillator Master Clock (CMOS Output). This pin can be used to monitor the output of the on-board master oscillator. 24 VDD1 Positive Power Supply. 3.3 V 25 PRI Primary Reference (Input). This input is a Primary reference source for synchronization. The module can synchronize to falling edge of the following reference clocks: 8 kHz, 1.544 MHz, 2.048 MHz or the rising edge of 19.44 MHz. This pin is selected when a logic 0 is applied to the RSel input pin. This pin is internally pulled up to VDD. 26 SEC Secondary Reference (Input). This input is a Secondary reference source for synchronization. The module can synchronize to falling edge of the following reference clocks: 8 kHz, 1.544 MHz, 2.048 MHz or the rising edge of 19.44 MHz. This pin is selected when a logic 1 is applied to the RSel input pin. This pin is internally pulled up to VDD. 27 IC 28 TCLR TIE Circuit Reset (Input). A high to low transition at this input initiates phase realignment between the input reference and the generated output clocks. This pin is internally pulled to GND. 29 RESET Reset (Input). Logic 0 will forces the module into a reset state. This pin must be held to logic 0 for a minimum of 1µs to reset the module properly. The module must be reset after power-up. 30 AGND1 Ground. 31 IC Internal Connection. Do not connect to this pin. 32 NC No Connection. This pin is unused and has no internal connection. 33 NC No Connection. This pin is unused and has no internal connection. 34 RSEL Reference Source Select (Input). A logic low selects the PRI (primary) reference source as the input reference signal and a logic high selects the SEC (secondary) input. This pin is internally pulled down to GND. See Table 1. 35 MS1 Mode/Control Select 1 (Input). This input, in conjunction with MS2, determines the state (Normal, Holdover or Freerun) of operation. See Table 2. 36 MS2 Mode/Control Select 2 (Input). This input, in conjunction with MS1, determines the state (Normal, Holdover or Freerun) of operation. See Table 2. 37 NC 38 HOLDOVER 39 NC JA 155-1 Clock (LVPECL Output). This differential output provides a low jitter 155.52 MHz clock. Ground. Positive Power Supply.3.3 V Ground. Internal Connection. Do not connect to this pin. No Connection. This pin is unused and has no internal connection. HOLDOVER (CMOS Output). This output goes to a logic high whenever the PLL goes into holdover mode. No Connection. This pin is unused and has no internal connection. 3 Zarlink Semiconductor Inc. ZL30462 Data Sheet Pin Description Table (continued) Pin Number Name 40 VDD 1.0 Description Positive Power Supply. 3.3 V Functional Description The ZL30462 offers a complete timing solution in a 1.2” x 1” module package. The module comprises three main components, a DPLL which performs the main operational functions, an APLL which provides three low jitter output clocks and an on-board master oscillator. Figure 1 shows a functional block diagram of the module, which is described in the following sections. 1.1 Reference Select MUX Circuit The ZL30462 accepts two simultaneous reference input signals which can be derived from independent sources. Both reference inputs will automatically accept one of four frequencies, 8 kHz, 1.544 MHz, 2.048 MHz or 19.44 MHz. The 8 kHz, 1.544 MHz and 2.048 MHz input clocks are all triggered on the falling edge and the 19.44 MHz is triggered on the rising edge. The primary reference (PRI) signal or the secondary reference (SEC) signal can be selected by simply using the RSEL pin, see Table 1. RSEL Input Reference 0 PRI 1 SEC Table 1 - Input Reference Selection 1.2 Time Interval Error (TIE) Corrector Circuit When the ZL30462 finishes locking to a reference an arbitrary phase difference will remain between its output clocks and its reference; this phase difference is part of the normal operation of the ZL30462. If so desired, the output clocks can be brought into phase alignment with the PLL reference by using the TCLR control pin. Using TCLR If the ZL30462 is locked to a reference, then the output clocks can be brought into phase alignment with the PLL reference by using the TCLR control pin according to the procedure below: • Wait until the ZL30462 LOCK indicator is high, indicating that it is locked • Pull TCLR low • Hold TCLR low for 250 µs for 1.544 MHz, 2.048 MHz or 19.44 MHz, or 10 sec for 8 kHz (input frequency). • Pull TCLR high This sequence re-initiates the ZL30462 locking procedure; the LOCK indicator will go low 5 sec after TCLR is pulled low and will remain low for 10 sec. 1.3 Core PLL The most critical element of the ZL30462 is the Core PLL. This generates a phase-locked clock filters wander and suppresses input phase transients.The Core PLL supports three mandatory modes of operation: Free-run, Normal (Locked) and Holdover. Each of these modes places specific requirements on the building blocks of the Core PLL. 4 Zarlink Semiconductor Inc. ZL30462 Data Sheet • In Free-run Mode, the Core PLL locks to the 20 MHz Master Clock Oscillator (OSC). The stability of the generated clock remains the same as the stability of the Master Clock Oscillator. • In Normal Mode, the Core PLL locks to one of the input reference clocks. Both inputs provide preprocessed phase data to the Core PLL including detection of reference clock quality. This preprocessing reduces the load on the Core PLL and improves quality of the generated clock. • In Holdover mode, the Core PLL generates a clock based on data collected from past reference signals. The Core PLL enters Holdover mode if the selected reference input is lost, or under external hardware control. Table 2 shows how each of these modes can be selected via the external hardware pins MS1 and MS2. MS2 MS1 Mode of Operation 0 0 Normal mode 0 1 Holdover mode 1 0 FreeRun mode 1 1 Reserved Table 2 - Operating Modes Within the DPLL there are a number of key components, which include a Phase Detector, Limiter, Loop Filter, Digitally Controlled Oscillator, Clock Synthersizer and Lock Indicator. 1.3.1 Phase Detector The Phase Detector compares the virtual reference signal from the TIE Corrector circuit, with its internal input frequency select circuit and provides an error signal corresponding to the phase difference between the two. This error signal is passed to the Limiter circuit. 1.3.2 Limiter The Limiter receives the error signal from the Phase Detector and ensures that the DPLL responds to all input transient conditions with a maximum output phase slope of 41 ns per 1.326 ms. 1.3.3 Loop Filter In Normal mode, the clocks generated by the ZL30462 are phase-locked to the input reference signal. The DPLL Loop Filter is similar to a first order low pass filter with a 1.5 Hz cutoff frequency for all four reference frequency selections (8 kHz, 1.544 MHz, 2.048 MHz or 19.44 MHz). This filter ensures that the wander transfer requirements in ETS 300 011 and AT&T TR62411 are met. 1.3.4 Digitally Controlled Oscillator (DCO) The DCO receives the limited and filtered signal from the Loop Filter, and based on its value, generates a corresponding digital output signal. The synchronization method of the DCO is dependent on the state of the ZL30462. In Normal Mode, the DCO provides an output signal which is frequency and phase locked to the selected input reference signal. In Holdover Mode, the DCO is free running at a frequency equal to the last (30 ms to 60 ms) frequency the DCO was generating while in Normal Mode. In Freerun Mode, the DCO is free running with an accuracy equal to the accuracy of the OSC 20 MHz source. 5 Zarlink Semiconductor Inc. ZL30462 1.3.5 Data Sheet Clock Synthesizer The output of the DCO is connected to the Clock Synthesizer that generates the output clocks and frame pulse. • C2o: 2.048 MHz clock with nominal 50% duty cycle • C8o: 8.192 MHz clock with nominal 50% duty cycle • C16o: 16.384 MHz clock with nominal 50% duty cycle • F16o: 8 kHz frequency, with 61 ns wide, logic low frame pulse In addition to the above, LK1 also generates a 19.44 MHz clock, which is linked externally to LK2. This clock drives the APLL stage which generates the low jitter 19.44 MHz and 155.52 MHz clock outputs (see Section 1.4). LK1: 1.3.6 19.44 MHz clock with nominal 50% duty cycle Lock Indicator (LOCK) The ZL30462 is considered locked (LOCK=1) when the residual phase movement after declaring locked condition does not exceed 20 ns; as required by standard wander generation MTIE and TDEV tests. To ensure the integrity of the LOCK status indication, the ZL30462 holds the LOCK pin low for a minimum of 10 sec. 1.4 Jitter Attenuator The ZL30462 output driver circuit provides two LVPECL jitter attenuated outputs at 155.52 MHz and one CMOS output at 19.44 MHz. There are no external components or adjustments required to support this part of the circuit, as the loop filter and additional power supply decoupling circuitry has been built into the module. The on-board loop filter has been optimized to ensure the quality of the jitter attenuated output. But to maintain the quality of these outputs it is extremely important that they are terminated correctly and the track impedance is 50 Ohms. Failure to do so will affect the modules performance will affect the quality of these clocks. Figure 3 shows one method of terminating one of the LVPECL outputs, further termination information can be found in the ZL30462 Applications Note. The input to the APLL stage can be isolated from the DPLL, by removing the link connection between LK1 (pin 5) and LK2 (pin 6), this may be useful for product verification or test purposes. 6 Zarlink Semiconductor Inc. ZL30462 Data Sheet Vcc Output Driver 127Ω 127Ω Ζ = 50Ω LVPECL Driver LVPECL Receiver Ζ = 50Ω 82.5Ω 82.5Ω Note : Vcc = +3.3V Figure 3 - LVPECL Output Termination Circuit 1.5 Input Impairment Monitor This circuit monitors both the input reference signals and reports their status automatically to the DPLL. This block automatically enables the Holdover Mode (Auto-Holdover) when the selected reference is outside the AutoHoldover capture range. (See AC Electrical Characteristics - Performance). This includes a complete loss of incoming signal, or a large frequency shift in the incoming signal. When the incoming signal returns to normal, the DPLL is returned to Normal Mode with the output signal locked to the input signal. The holdover output signal in the ZL30462 is based on the incoming signal 30 ms minimum to 60 ms prior to entering the Holdover Mode. The amount of phase drift while in holdover is negligible because the Holdover Mode is very accurate (e.g., <±0.01 ppm, relative to the master oscillator frequency). Consequently, the phase delay between the input and output after switching back to Normal Mode is preserved. 1.6 Control State Machine The ZL30462 Control State Machine supporting the three mandatory clock modes required by any Network Element that operates in a synchronous network. The simplified version of this state machine is shown in Figure 4 and includes the mandatory states: Free-run, Normal and Holdover. These states are complemented by two additional states: Reset and Auto Holdover, which are critical to the ZL30462 operation under the changing external conditions. These clock modes determine the behavior of a Network Element to the unforeseen changes in the network synchronization hierarchy. Requirements for clock modes are defined in the international standards e.g.: G.812, G.813, GR-1244-CORE and GR-253-CORE and they are very strictly enforced by network operators. Figure 4 also shows how the control input pins - RSEL, MS1, MS2 and RESET interact with the Control State Machine. 7 Zarlink Semiconductor Inc. ZL30462 MS2, MS1 == 01 or RSEL change ______ RESET == 1 Reset Ref: OK & MS2, MS1 == 00 {Auto} Data Sheet Normal (Locked) 00 MS2, MS1 != 10 FreeRun 10 Holdover 01 Ref: Fail --> OK & MS2, MS1 == 00 & AHRD=1 & MHR 0 --> 1 {Manual} Ref: OK --> Fail & MS2, MS1 == 00 {Auto} RSEL change Ref: Fail --> OK & MS2, MS1 == 00 & AHRD=0 & {Auto} Auto Holdover MS2, MS1 == 10 forces unconditional return from any state to FreeRun Notes: == : equal != : not equal &= : AND operation 0 --> 1 : transition from 0 to 1 {Auto} : Automatic transition {Manual} : Manual transition Auto Holdover: Automatic Holdover {AHRD} : Automatic Holdover {MHR} : Manual Holdover State MS2, MS1 Figure 4 - ZL30462 State Machine 1.6.1 Reset State In this state, the DPLL clocks are stopped and all functions are initialized. The Reset state is entered by pulling the RESET pin to logic 0 for a minimum of 1 µs. When the RESET pin is pulled back to logic 1, internal logic starts a 625 µs initialization process before switching into the Free-run state (MS2, MS1 = 10). It is recommended that a module reset is performed immediately after power up, to ensure the ZL30462 is set to a know state. The RESET function would normally be under the control of the system or host controller, usually in the form of a microprocessor or FPGA. Alternatively, Figure 5 shows how to connect a simple hardware reset circuit to the ZL30462. Vdd ZL30462 R 10k ______ RESET Rp 1k C 10nF Figure 5 - Simple Reset Circuit 8 Zarlink Semiconductor Inc. ZL30462 1.6.2 Data Sheet Free-Run State The Free-run state is entered when synchronization to the network is not required or is not possible. Typically this occurs during installation, repairs or when a Network Element operates as a master node in an isolated network. In the Free-run state, the accuracy of the generated clocks is determined by the accuracy and stability of the ZL30462 Master Crystal Oscillator. When powering up the equipment, it is recommended that the module has at least 2 hours to stabilize after the equipment has reached its normal operating temperature. 1.6.3 Normal State (Locked State) The Normal State is entered when Normal mode is selected and a good quality reference clock is available. The ZL30462 automatically detects the frequency of the reference clock (8 kHz, 1.544 MHz, 2.048 MHz or 19.44 MHz) and sets the LOCK status pin to logic 1 after acquiring synchronization. In the Normal state all generated clocks (C2o, C8o, C16o, JA19Mo, JA155P/N-1 and JA155P/N-2) and frame pulse (F16o) are derived from network timing. To guarantee uninterrupted synchronization, the ZL30462 continuously monitors the quality of both input reference clocks. This dual architecture enables quick replacement of a poor or failed reference and minimizes the time spent in other states. During this state the ZL30462 can tolerate a 17 ppm/s frequency change (on the active input) without generating an alarm or changing state. 1.6.4 Holdover State The Holdover State is typically entered for short durations while network synchronization is temporarily disrupted. In Holdover Mode, the ZL30462 generated clocks are not locked to an external reference signal, but these outputs are based on stored coefficients in memory. These coefficients are determined while the module is in Normal State for at least 10 minute after the modules stabilization period.” The initial frequency offset of the ZL30462’s DPLL in Holdover Mode is ±1x10-10. Once the ZL30462 has transitioned into Holdover Mode, holdover stability is determined by the stability of the 20 MHz Master Clock Oscillator (OSC pin), which is a ±20 ppm crystal oscillator. 1.6.5 Auto Holdover State The Auto Holdover state is a transitional state that the ZL30462 enters automatically when the active reference fails unexpectedly. When the ZL30462 detects loss of reference it waits in Auto Holdover state until the failed reference recovers. The HOLDOVER status pin may be used to alert the system controller about the failure and in response the controller may switch to the secondary reference clock. The HOLDOVER pin indicates when you are in either Auto Holdover and Holdover states. If the selected input fails (or becomes invalid for any reason) the ZL30462 will transition into Auto-Holdover. If the system controller then elects to switch to the other input and that input is also invalid, then the ZL30462 will remain in Auto Holdover until that input becomes valid. This is an internal protection system, to ensure that the module does not use an invalid reference. If the ZL30462 is reset at any time (e.g., during power-up) and mode select pins are trying to force the module to lock to an invalid input (MS1, MS2 == 00) the module will transition into Auto Holdover and the HOLDOVER pin will be asserted. Because the reset function clears the ZL30462’s memory, then there will be no holdover history. In this case, even though the output status pin is showing that the module is in Holdover, the output clock accuracy will default to that of Freerun mode. So to summarise the above, in a typical Network Element application, the ZL30462 will typically operate in Normal mode (MS2, MS1 == 00) generating synchronous clocks. The State Machine is designed to perform some transitions automatically, leaving other, less time dependent tasks to the system controller. The state machine includes two stimulus signals which are critical to automatic operation: “OK --> FAIL” and “FAIL --> OK” that represent loss (and recovery) of the reference signal or its drift by more than ±30000 ppm. Their transitions force 9 Zarlink Semiconductor Inc. ZL30462 Data Sheet the DPLL to move into and out of the Auto Holdover state. The ZL30462 State Machine may also be driven by controlling the mode select pins MS2, MS1. To avoid network synchronization problems, the State Machine has built-in basic protection that does not allow switching the DPLL into a state where it cannot operate correctly e.g., it is not possible to force the DPLL into Normal mode when all references are lost. 2.0 Applications This section details how to control and monitor the hardware pins of the ZL30462 and general power supply decoupling information. More detailed application information can be found in the ZL30462 Applications Note. 2.1 ZL30462 Mode Switching - Examples The ZL30462 is designed to transition from one mode to the other driven by the internal State Machine or by manual control. The following examples present a couple of typical scenarios of how the ZL30462 can be employed in network synchronization equipment (e.g., timing modules, line cards or stand alone synchronizers). 2.1.1 System Start-up Sequence: FREE-RUN --> HOLDOVER --> NORMAL The Free-run to Holdover to Normal transition represents a sequence of steps that will most likely occur during a new system installation or scheduled maintenance of timing cards. The process starts from the RESET state and then transitions to Free-run when the device is being initialized. At the end of this process the ZL30462 should be switched into Normal mode (with MS2, MS1 set to 00) instead of Holdover mode. If the reference clock is available, the ZL30462 will transition briefly into Holdover state to acquire synchronization and switch automatically to Normal state. If the reference clock is not available the ZL30462 will stay in Holdover state indefinitely. Whilst in Holdover state, the DPLL will continue generating clocks with the same accuracy as in the Free-run mode, waiting for a valid reference clock. When the system is connected to the network (or timing card switched to a valid reference) this will enable the DPLL to start the synchronization process. After acquiring lock, the ZL30462 will automatically switch from Holdover state to Normal state without system intervention. This transition to the Normal state will be flagged by the LOCK status pin. MS2, MS1 == 01 or RSEL change ______ RESET == 1 Reset Ref: OK & MS2, MS1 == 00 {Auto} Normal (Locked) 00 MS2, MS1 != 10 FreeRun 10 Holdover 01 RSEL change Ref: Fail --> OK & MS2, MS1 == 00 & AHRD=1 & MHR 0 --> 1 {Manual} Ref: OK --> Fail & MS2, MS1 == 00 {Auto} Ref: Fail --> OK & MS2, MS1 == 00 & AHRD=0 & {Auto} Auto Holdover MS2, MS1 == 10 forces unconditional return from any state to FreeRun Figure 6 - Transition from Free-run to Normal mode 10 Zarlink Semiconductor Inc. ZL30462 2.1.2 Data Sheet Single Reference Operation: NORMAL --> AUTO HOLDOVER --> NORMAL The Normal to Auto-Holdover to Normal transition will usually happen when the Network Element loses its single reference clock unexpectedly or when it has two references but switching to the secondary reference is not a desirable option. The sequence starts with the unexpected failure of a reference signal shown as transition OK --> FAIL in Figure 7 at a time when ZL30462 operates in Normal mode. This failure is detected at the active input based on the following FAIL criteria: • Frequency offset on 8 kHz, 1.544 MHz, 2.048 MHz and 19.44 MHz reference clocks exceeds ±30000 ppm (±3%). • Phase hit on 1.544 MHz, 2.048 MHz and 19.44 MHz exceeds half of the cycle of the reference clock. After detecting any of these anomalies on a reference clock the Control State Machine will force the DPLL to automatically switch into the Auto Holdover state. This condition is flagged by LOCK = 0 and HOLDOVER = 1. MS2, MS1 == 01 or RSEL change ______ RESET == 1 Reset Ref: OK & MS2, MS1 == 00 {Auto} Normal (Locked) 00 MS2, MS1 != 10 FreeRun 10 Holdover 01 RSEL change Ref: Fail --> OK & MS2, MS1 == 00 & AHRD=1 & MHR 0 --> 1 {Manual} Ref: OK --> Fail & MS2, MS1 == 00 {Auto} Ref: Fail --> OK & MS2, MS1 == 00 & AHRD=0 & {Auto} Auto Holdover Automatic return to Normal: AHDR=0 or Manual return to Normal: AHRD=1 & MHR 0--> 1 MS2, MS1 == 10 forces unconditional return from any state to FreeRun Figure 7 - Automatic entry into Auto Holdover State and recovery into Normal mode The ZL30462 will automatically return to the Normal state after the reference signal recovers from failure. This transition is shown on the state diagram as a FAIL --> OK change. This change becomes effective when the reference is restored and there have been no phase hits detected for at least 64 clock cycles. This transition from Auto Holdover to Normal state is performed as “hitless” reference switching. 2.1.3 Dual Reference Operation: NORMAL --> AUTO HOLDOVER --> HOLDOVER --> NORMAL The Normal to Auto-Holdover to Holdover to Normal sequence represents the most likely operation of ZL30462 in Network Equipment. The sequence starts from the Normal state and transitions to Auto Holdover state due to an unforeseen loss of reference. The failure conditions triggering this transition were described in Section 2.1.2. When in the Auto Holdover state, the ZL30462 can return to Normal state automatically if the lost reference is restored. If the reference clock failure persists for a period of time that exceeds the system design limit, the system control processor may initiate a reference switch. If the secondary reference is available the ZL30462 will briefly switch into Holdover state and then transition to Normal state. 11 Zarlink Semiconductor Inc. ZL30462 MS2, MS1 == 01 or RSEL change ______ RESET == 1 Reset Ref: OK & MS2, MS1 == 00 {Auto} Data Sheet Normal (Locked) 00 MS2, MS1 != 10 FreeRun 10 Holdover 01 Ref: Fail --> OK & MS2, MS1 == 00 & AHRD=1 & MHR 0 --> 1 {Manual} Ref: OK --> Fail & MS2, MS1 == 00 {Auto} Ref: Fail --> OK & MS2, MS1 == 00 & AHRD=0 & {Auto} Auto Holdover RSEL change AHRD=0 (automatic return enabled) MS2, MS1 == 10 forces unconditional return from any state to FreeRun Figure 8 - Entry into Auto Holdover state and recovery into Normal mode by switching references The new reference clock will most likely have a different phase but it may also have a different fractional frequency offset. To lock to a new reference with a different frequency, the DPLL will step gradually towards the new frequency. The frequency slope will be limited to less than 2.0 ppm/sec. 2.1.4 Reference Switching (RefSel): NORMAL --> HOLDOVER --> NORMAL The Normal to Holdover to Normal sequence switching can be performed at any time. An example of this could be during routine maintenance or an upgrade of equipment, where the active input references is going to be affected. So, changing the input reference under controlled conditions should avoid any unnecessary chances of generating a phase hit. MS2, MS1 == 01 or RSEL change ______ RESET == 1 Reset Ref: OK & MS2, MS1 == 00 {Auto} Normal (Locked) 00 MS2, MS1 != 10 FreeRun 10 Holdover 01 Ref: Fail --> OK & MS2, MS1 == 00 & AHRD=1 & MHR 0 --> 1 {Manual} Ref: OK --> Fail & MS2, MS1 == 00 {Auto} RSEL change MS2, MS1 == 10 forces unconditional return from any state to FreeRun Figure 9 - Manual Reference Switching 12 Zarlink Semiconductor Inc. Ref: Fail --> OK & MS2, MS1 == 00 & AHRD=0 & {Auto} Auto Holdover ZL30462 Data Sheet Two types of transitions are possible: • Semi-automatic transition, which involves changing the RSEL input to select the other reference clock, without changing the mode select inputs MS2, MS1 = 00 (Normal mode). This forces ZL30462 to momentarily transition through the Holdover state and automatically return to Normal state after synchronizing to the other reference clock. • Manual transition, which involves switching into Holdover mode (MS2, MS1 = 01), changing references with RSEL, and manual return to the Normal mode (MS2, MS1 = 00). In both cases, the change of references provides “hitless” switching. 2.2 Power Supply Decoupling Figure 10 shows the recommended power supply decoupling requirements of the ZL30462. The ZL30462 does have a level of internal decoupling components built in to the module, but to ensure optimum performance these external components are required. L1 3.3V L1 & L2 : 10µH C2 & C5 : 10µF C1, C3, C4, C6 - C9 : 100nF TVdd C1 C2 C3 TGnd L2 C4 Vdd C5 C6 AGnd1 Vdd1 C7 ZL30462 AGnd1 Vdd2 C8 AGnd1 Vdd3 C9 AGnd2 Figure 10 - Power Supply Decoupling 13 Zarlink Semiconductor Inc. ZL30462 3.0 Characteristics 3.1 AC and DC Electrical Characteristics Data Sheet Absolute Maximum Ratings* Parameter 1 Symbol Min. Max. Units VDD TVDD -0.3 -0.3 5.0 5.0 V V Supply Voltages 2 Input Voltage VIN -0.05 VDD+0.5 * Voltages are with respect to ground (GND) unless otherwise stated. * Exceeding these values may cause permanent damage. Functional operation under these conditions is not implied. V Recommended Operating Conditions* Parameter 1 Supply Voltages 2 Operating Temperature Symbol Min Typ. Max. Units VDD TVDD 3.0 3.3 3.6 V TA 0 25 70 ºC Typ. Max. Units Test Conditions * Voltages are with respect to ground (GND) unless otherwise stated. DC Electrical Characteristics* Characteristics Symbol Min. 1 Supply Current IDD 325 450 mA Output unloaded 2 Supply Current TIDD 5 10 mA Output unloaded 3 CMOS: High-level input voltage VIH 0.7VDD 4 CMOS: Low-level input voltage VIL 0 5 CMOS: Input leakage current IIL 6 CMOS: High-level output voltage VOH 7 CMOS: Low-level output voltage VOL 8 LVPECL: Differential output voltage |VOD| 9 LVPECL: High-level output voltage VOH 10 LVPECL: Low-level output voltage VOL 11 LVPECL: Output rise and fall times TRF V 0.3VDD V 15 µA VI=VDD or GND V IOH = 8mA 0.4 V IOL = 8mA 720 mVp ZT=100 Ohms VDD-0.9 V ZT=100 Ohms VDD-1.5 V 2.4 480 250 600 300 * Voltages are with respect to ground (GND) unless otherwise stated. Note 1: Rise and fall times are measured at 20% and 80% levels. 14 Zarlink Semiconductor Inc. 700 ps Note 1 ZL30462 Data Sheet AC Electrical Characteristics* Parameter Symbol Min. Max. Units Test Conditions FA -20 20 ppm Note 2 1 Freerun Mode accuracy 2 Holdover Mode accuracy FA-0.01 FA+0.01 ppm Note 3 3 Lock range FA-104 FA+104 ppm Note 4 4 Wander Generation 5 WGEN ITU-T G.813 Option1 Wander Transfer WTR ITU-T G.813 Option1 6 Phase response to input signal interruptions PTT ITU-T G.813 Option1 7 Phase Transients PT ITU-T G.813 Option1 8 Holdover Entry Phase Transients HEPT ITU-T G.813 Option1 9 Lock Time 30 LT s * Voltages are with respect to ground (GND) unless otherwise stated. Note 2: The Freerun accuracy is directly related to the accuracy of the master oscillator. Note 3: The DPLL Holdover accuracy is also affected by the holdover stability of the master oscillator. Note 4: This figure is offset by the accuracy of the master oscillator. AC Electrical Characteristics* - Timing Parameter Measurements - CMOS Voltage Levels* Characteristics Symbol Typical Units VT 0.5VDD V 1 Threshold voltage 2 Rise and fall threshold voltage High VHM 0.7VDD V 3 Rise and fall threshold voltage Low VLM 0.3VDD V * Voltages are with respect to ground (GND) unless otherwise stated. Timing Reference Points V HM VT V LM All Signals T IF, TOF T IR, TOR Figure 11 - Timing Parameters Measurement Voltage Levels 15 Zarlink Semiconductor Inc. ZL30462 Data Sheet AC Electrical Characteristics - Input Phase Alignment Characteristics Symbol Min. 1 8 kHz ref. pulse width high tR8H 100 2 8 kHz ref. input to F16o delay tR8D 43 3 1.544 MHz ref. pulse width high tR1.5H 100 4 1.544 MHz ref. input to F16o delay tR1.5D 360 5 2.048 MHz ref. pulse width high tR2H 100 6 2.048 MHz ref. input to F16o delay tR2D 252 7 19.44 MHz ref. pulse width high tR19H 23 8 19.44 MHz ref. input to F16o delay tR19D 30 9 Reference input rise and fall time tIR, tIF t R8H Max. Units Test Conditions ns 61 ns ns 393 ns ns 288 ns ns 51 ns 10 ns t R8D PRI/SEC 8kHz VT tR1.5H tc = 125µs tR1.5D PRI/SEC 1.544MHz VT t R2H tc = 647.67ns t R2D PRI/SEC 2.048MHz VT tc = 488.28ns t R19H t R19D PRI/SEC 19.44MHz VT tc = 51.44ns VT /F16o tc = 125µs Figure 12 - Input to Output Timing (Normal Mode) 16 Zarlink Semiconductor Inc. ZL30462 Data Sheet AC Electrical Characteristics - Input Control Signals Characteristics Symbol Min. Max. Units 1 Input Controls Setup Time tS 100 ns 2 Input Controls Hold Time tH 100 ns /F16o Test Conditions VT tS tH MS1, MS2, RSEL, VT Figure 13 - Input Control Signal Setup and Hold Time AC Electrical Characteristics - Outputs Timing Characteristics Symbol Min. Max. Units 1 F16o to JA19Mo delay tJ19D -35 -25 ns 4 F16o to C16o delay tC16D -35 -25 ns 5 F16o to C8o delay tC8D -35 -25 ns 6 F16o to C2o delay tC2D -35 -25 ns 17 Zarlink Semiconductor Inc. Test Conditions ZL30462 /F16o Data Sheet VT tc = 125µs t J19D JA19Mo VT tc = 51.44ns t C16D /C16o VT tc = 61.035ns t C8D C8o VT tc = 122.07ns t C2D C2o VT tc = 488.28ns Figure 14 - Output Timing 18 Zarlink Semiconductor Inc. ZL30462 3.2 Data Sheet Performance Characteristics Performance Characteristics: Measured Output Jitter - GR-253-CORE and T1.105.03 conformance* Telcordia GR-253-CORE and ANSI T1.105.03 Jitter Generation Requirements Interface Jitter Measurement Filter Equivalent limit in time domain Limit in UI ZL30462 Jitter Generation Performance TYP Units Notes JA155P/N Clock Output 1 OC-12 622.08 Mbit/s 12 kHz to 5 MHz (Category II) 0.1 UIPP 161 24.2 psP-P 1.905 psRMS JA19Mo Clock Output 2 OC-3 155.54 Mbit/s 3 65 kHz to 1.3 MHz 12 kHz to 1.3 MHz (Category II) 964 0.15 UIPP 0.1 UIPP 643 283.1 psP-P 22.89 psRMS 209.4 psP-P 16.49 psRMS * Supply voltage and operating temperature are as per Recommended Operating Conditions. Performance Characteristics: Measured Output Jitter - G.732, G.735 to G.739 conformance* ITU-T G.732, G.735, G.736, G.737, G.738, G739 Jitter Generation Requirements Interface Jitter Measurement Filter Equivalent limit in time domain Limit in UI ZL30462 Jitter Generation Performance TYP Units Notes C16o, C8 and C2 Clock Outputs 1 E1 2048 kbits/s 20 Hz to 100 kHz 0.05 UIPP 24.4 * Supply voltage and operating temperature are as per Recommended Operating Conditions. 19 Zarlink Semiconductor Inc. 1.26 nsP-P ZL30462 Data Sheet Performance Characteristics: Measured Output Jitter - G.813 conformance - Option 1 ITU-T G.813 Jitter Generation Requirements Jitter Measurement Filter Interface Limit in UI ZL30462 Jitter Generation Performance Equivalent limit in time domain TYP Units Notes JA155P/N Clock Output 1 STM-4 622.08 Mbit/s 250 kHz to 5 MHz 0.1 UIPP 161 11.9 psP-P 0.94 psRMS JA19Mo Clock Output 2 STM-1 155.54 Mbit/s 65 kHz to 1.3 MHz 0.1 UIPP 643 283.1 psP-P 22.89 psRMS C16o, C8o and C2o Clock Output 3 E1 2048 kbit/s 20 Hz to 100 kHz 0.05 UIPP 24.4 1.26 nsP-P * Supply voltage and operating temperature are as per Recommended Operating Conditions. Performance Characteristics: Measured Output Jitter - G.813 conformance - Option 2 ITU-T G.813 Jitter Generation Requirements Interface Jitter Measurement Filter ZL30462 Jitter Generation Performance Equivalent limit in time domain Limit in UI TYP Units JA155P/N Clock Output 1 STM-4 622.08 Mbit/s 12 kHz to 5 MHz 161 0.1 UIPP 24.2 psP-P 1.905 psRMS JA19Mo Clock Output 2 STM-1 155.54 Mbit/s 65 kHz to 1.3 MHz 643 0.1 UIPP 20 Zarlink Semiconductor Inc. 283.1 psP-P 22.89 psRMS Notes Package Code c Zarlink Semiconductor 2003 All rights reserved. ISSUE 1 ACN --- DATE 15 Oct 03 APPRD. Previous package codes For more information about all Zarlink products visit our Web Site at www.zarlink.com Information relating to products and services furnished herein by Zarlink Semiconductor Inc. or its subsidiaries (collectively “Zarlink”) is believed to be reliable. However, Zarlink assumes no liability for errors that may appear in this publication, or for liability otherwise arising from the application or use of any such information, product or service or for any infringement of patents or other intellectual property rights owned by third parties which may result from such application or use. Neither the supply of such information or purchase of product or service conveys any license, either express or implied, under patents or other intellectual property rights owned by Zarlink or licensed from third parties by Zarlink, whatsoever. Purchasers of products are also hereby notified that the use of product in certain ways or in combination with Zarlink, or non-Zarlink furnished goods or services may infringe patents or other intellectual property rights owned by Zarlink. This publication is issued to provide information only and (unless agreed by Zarlink in writing) may not be used, applied or reproduced for any purpose nor form part of any order or contract nor to be regarded as a representation relating to the products or services concerned. The products, their specifications, services and other information appearing in this publication are subject to change by Zarlink without notice. No warranty or guarantee express or implied is made regarding the capability, performance or suitability of any product or service. Information concerning possible methods of use is provided as a guide only and does not constitute any guarantee that such methods of use will be satisfactory in a specific piece of equipment. It is the user’s responsibility to fully determine the performance and suitability of any equipment using such information and to ensure that any publication or data used is up to date and has not been superseded. Manufacturing does not necessarily include testing of all functions or parameters. These products are not suitable for use in any medical products whose failure to perform may result in significant injury or death to the user. All products and materials are sold and services provided subject to Zarlink’s conditions of sale which are available on request. Purchase of Zarlink’s I2C components conveys a licence under the Philips I2C Patent rights to use these components in and I2C System, provided that the system conforms to the I2C Standard Specification as defined by Philips. Zarlink, ZL and the Zarlink Semiconductor logo are trademarks of Zarlink Semiconductor Inc. Copyright Zarlink Semiconductor Inc. All Rights Reserved. TECHNICAL DOCUMENTATION - NOT FOR RESALE