SONY ICX418AKB

ICX418AKB
Diagonal 8mm (Type 1/2) CCD Image Sensor for NTSC Color Video Cameras
Description
The ICX418AKB is an interline CCD solid-state
image sensor suitable for NTSC color video cameras
with a diagonal 8mm (Type 1/2) system. Compared
with the current product ICX038DNB, basic
characteristics such as sensitivity, smear, dynamic
range and S/N are improved drastically.
This chip features a field period readout system and
an electronic shutter with variable charge-storage
time. Also, this outline is miniaturized by using
original package. This chip is compatible with the
pins of the ICX038DNB and has the same drive
conditions.
16 pin DIP (Ceramic)
Pin 1
2
V
Features
• High sensitivity (+6.0dB compared with the ICX038DNB)
3
• Low smear (–5.0dB compared with the ICX038DNB)
40
H
Pin 9
• High D range (+2.0dB compared with the ICX038DNB)
• High S/N
Optical black position
• High resolution and low dark current
(Top View)
• Excellent antiblooming characteristics
• Ye, Cy, Mg, and G complementary color mosaic filters on chip
• Continuous variable-speed shutter
• Substrate bias:
Adjustment free (external adjustment also possible with 6 to 14V)
• Reset gate pulse:
5Vp-p adjustment free (drive also possible with 0 to 9V)
• Horizontal register:
5V drive
• Maximum package dimensions: φ13.2mm
12
Device Structure
• Interline CCD image sensor
• Optical size:
Diagonal 8mm (Type 1/2)
• Number of effective pixels: 768 (H) × 494 (V) approx. 380K pixels
• Total number of pixels:
811 (H) × 508 (V) approx. 410K pixels
• Chip size:
7.40mm (H) × 5.95mm (V)
• Unit cell size:
8.4µm (H) × 9.8µm (V)
• Optical black:
Horizontal (H) direction: Front 3 pixels, rear 40 pixels
Vertical (V) direction:
Front 12 pixels, rear 2 pixels
• Number of dummy bits:
Horizontal 22
Vertical 1 (even fields only)
• Substrate material:
Silicon
Sony reserves the right to change products and specifications without prior notice. This information does not convey any license by
any implication or otherwise under any patents or other right. Application circuits shown, if any, are typical examples illustrating the
operation of the devices. Sony cannot assume responsibility for any problems arising out of the use of these circuits.
–1–
E01907A41
ICX418AKB
USE RESTRICTION NOTICE (December 1, 2003 ver.)
This USE RESTRICTION NOTICE ("Notice") is for customers who are considering or currently using the CCD
products ("Products") set forth in this specifications book. Sony Corporation ("Sony") may, at any time, modify
this Notice which will be available to you in the latest specifications book for the Products. You should abide by
the latest version of this Notice. If a Sony subsidiary or distributor has its own use restriction notice on the
Products, such a use restriction notice will additionally apply between you and the subsidiary or distributor. You
should consult a sales representative of the subsidiary or distributor of Sony on such a use restriction notice
when you consider using the Products.
Use Restrictions
• The Products are intended for incorporation into such general electronic equipment as office products,
communication products, measurement products, and home electronics products in accordance with the
terms and conditions set forth in this specifications book and otherwise notified by Sony from time to time.
• You should not use the Products for critical applications which may pose a life- or injury- threatening risk or
are highly likely to cause significant property damage in the event of failure of the Products. You should
consult your Sony sales representative beforehand when you consider using the Products for such critical
applications. In addition, you should not use the Products in weapon or military equipment.
• Sony disclaims and does not assume any liability and damages arising out of misuse, improper use,
modification, use of the Products for the above-mentioned critical applications, weapon and military
equipment, or any deviation from the requirements set forth in this specifications book.
Design for Safety
• Sony is making continuous efforts to further improve the quality and reliability of the Products; however,
failure of a certain percentage of the Products is inevitable. Therefore, you should take sufficient care to
ensure the safe design of your products such as component redundancy, anti-conflagration features, and
features to prevent mis-operation in order to avoid accidents resulting in injury or death, fire or other social
damage as a result of such failure.
Export Control
• If the Products are controlled items under the export control laws or regulations of various countries, approval
may be required for the export of the Products under the said laws or regulations. You should be responsible
for compliance with the said laws or regulations.
No License Implied
• The technical information shown in this specifications book is for your reference purposes only. The
availability of this specifications book shall not be construed as giving any indication that Sony and its
licensors will license any intellectual property rights in such information by any implication or otherwise. Sony
will not assume responsibility for any problems in connection with your use of such information or for any
infringement of third-party rights due to the same. It is therefore your sole legal and financial responsibility to
resolve any such problems and infringement.
Governing Law
• This Notice shall be governed by and construed in accordance with the laws of Japan, without reference to
principles of conflict of laws or choice of laws. All controversies and disputes arising out of or relating to this
Notice shall be submitted to the exclusive jurisdiction of the Tokyo District Court in Japan as the court of first
instance.
Other Applicable Terms and Conditions
• The terms and conditions in the Sony additional specifications, which will be made available to you when you
order the Products, shall also be applicable to your use of the Products as well as to this specifications book.
You should review those terms and conditions when you consider purchasing and/or using the Products.
–2–
ICX418AKB
VDD
VL
Vφ1
φSUB
Vφ2
Vφ3
Vφ4
8
7
6
5
4
3
2
1
Vertical Register
VOUT
Block Diagram and Pin Configuration
(Top View)
Cy
Ye
Cy
Ye
Mg
G
Mg
G
Cy
Ye
Cy
Ye
G
Mg
G
Mg
Cy
Ye
Cy
Ye
Mg
G
Mg
G
Note)
Horizontal Register
14
15
16
Hφ1
Hφ2
13
VDSUB
12
φRG
NC
11
RD
10
GND
9
NC
Note)
: Photo sensor
Pin Description
Pin No. Symbol
Description
Pin No. Symbol
Description
1
Vφ4
Vertical register transfer clock
9
NC
2
Vφ3
Vertical register transfer clock
10
NC
3
Vφ2
Vertical register transfer clock
11
GND
GND
4
φSUB
Substrate clock
12
RD
Reset drain bias
5
Vφ1
Vertical register transfer clock
13
φRG
Reset gate clock
6
VL
Protective transistor bias
14
VDSUB
Substrate bias circuit supply voltage
7
VDD
Output circuit supply voltage
15
Hφ1
Horizontal register transfer clock
8
VOUT
Signal output
16
Hφ2
Horizontal register transfer clock
–3–
ICX418AKB
Absolute Maximum Ratings
Item
Ratings
Unit
–0.3 to +50
V
VDD, VRD, VDSUB, VOUT – GND
–0.3 to +18
V
VDD, VRD, VDSUB, VOUT – φSUB
–55 to +10
V
Vφ1, Vφ2, Vφ3, Vφ4 – GND
–15 to +20
V
Vφ1, Vφ2, Vφ3, Vφ4 – φSUB
to +10
V
Voltage difference between vertical clock input pins
to +15
V
Voltage difference between horizontal clock input pins
to +17
V
Hφ1, Hφ2 – Vφ4
–17 to +17
V
φRG – GND
–10 to +15
V
φRG – φSUB
–55 to +10
V
VL – φSUB
–65 to +0.3
V
Pins other than GND and φSUB – VL
–0.3 to +30
V
Storage temperature
–30 to +80
°C
Operating temperature
–10 to +60
°C
Substrate clock φSUB – GND
Supply voltage
Clock input voltage
∗1 +27V (Max.) when clock width < 10µs, clock duty factor < 0.1%.
–4–
Remarks
∗1
ICX418AKB
Bias Conditions 1 [when used in substrate bias internal generation mode]
Item
Symbol
Min.
Typ.
Max.
Unit
Output circuit supply voltage
VDD
14.55
15.0
15.45
V
Reset drain voltage
VRD
14.55
15.0
15.45
V
Protective transistor bias
VL
Substrate bias circuit supply voltage
VDSUB
15.45
V
Substrate clock
φSUB
Remarks
VRD = VDD
∗1
14.55
15.0
∗2
∗1 VL setting is the VVL voltage of the vertical transfer clock waveform, or the same supply voltage as the VL
power supply for the V driver should be used. (When CXD1267AN is used.)
∗2 Do not apply a DC bias to the substrate clock pin, because a DC bias is generated within the CCD.
Bias Conditions 2 [when used in substrate bias external adjustment mode]
Item
Symbol
Min.
Typ.
Max.
Unit
Remarks
Output circuit supply voltage
VDD
14.55
15.0
15.45
V
Reset drain voltage
VRD
14.55
15.0
15.45
V
VRD = VDD
Protective transistor bias
VL
∗3
Substrate bias circuit supply voltage
VDSUB
∗4
Substrate voltage adjustment range
VSUB
6.0
14.0
V
∗5
Substrate voltage adjustment precision
∆VSUB
–3
+3
%
∗5
∗3 VL setting is the VVL voltage of the vertical transfer clock waveform, or the same supply voltage as the VL
power supply for the V driver should be used. (When CXD1267AN is used.)
∗4 Connect to GND or leave open.
∗5 The setting value of the substrate voltage (VSUB) is indicated on the back of the image sensor by a
special code. When adjusting the substrate voltage externally, adjust the substrate voltage to the indicated
voltage. The adjustment precision is ±3%. However, this setting value has not significance when used in
substrate bias internal generation mode.
VSUB code — one character indication
Code and optimal setting correspond to each other as follows.
VSUB code
E
Optimal setting 6.0
f
G
h
J
K
L
m
6.5
7.0
7.5
8.0
8.5
9.0
N
P
Q
R
S
T
DC Characteristics
Output circuit supply current
Symbol
V
W
9.5 10.0 10.5 11.0 11.5 12.0 12.5 13.0 13.5 14.0
<Example> "L" → VSUB = 9.0V
Item
U
Min.
IDD
–5–
Typ.
Max.
Unit
5.0
10.0
mA
Remarks
ICX418AKB
Clock Voltage Conditions
Item
Readout clock voltage
Vertical transfer clock
voltage
Horizontal transfer
clock voltage
Symbol
Min.
Waveform
diagram
Remarks
VVT
14.55 15.0 15.45
V
1
VVH1, VVH2
–0.05
0
0.05
V
2
VVH3, VVH4
–0.2
0
0.05
V
2
VVL1, VVL2,
VVL3, VVL4
–9.6 –9.0 –8.5
V
2
VVL = (VVL3 + VVL4)/2
VφV
8.3
9.65 Vp-p
2
VφV = VVHn – VVLn (n = 1 to 4)
0.1
V
2
9.0
| VVH1 – VVH2 |
VVH = (VVH1 + VVH2)/2
VVH3 – VVH
–0.25
0.1
V
2
VVH4 – VVH
–0.25
0.1
V
2
VVHH
0.5
V
2
High-level coupling
VVHL
0.5
V
2
High-level coupling
VVLH
0.5
V
2
Low-level coupling
VVLL
0.5
V
2
Low-level coupling
VφH
4.75
5.0
VHL
–0.05
0
VφRG
4.5
5.0
VRGLH – VRGLL
Substrate clock voltage VφSUB
5.25 Vp-p
3
0.05
V
3
V
4
∗1
VRGL
Reset gate clock
voltage∗1
Typ. Max. Unit
5.5 Vp-p
4
0.8
4
V
23.0 24.0 25.0 Vp-p
Low-level coupling
5
∗1 Input the reset gate clock without applying a DC bias. In addition, the reset gate clock can also be driven
with the following specifications.
Item
Reset gate clock
voltage
Symbol
Min.
Typ. Max. Unit
VRGL
–0.2
0
VφRG
8.5
9.0
0.2
V
9.5 Vp-p
–6–
Waveform
diagram
4
4
Remarks
ICX418AKB
Clock Equivalent Circuit Constant
Symbol
Item
Typ.
Min.
Max.
Unit
CφV1, CφV3
2700
pF
CφV2, CφV4
2700
pF
CφV12, CφV34
820
pF
CφV23, CφV41
330
pF
Capacitance between horizontal transfer clock CφH1
and GND
CφH2
100
pF
91
pF
Capacitance between horizontal transfer clocks
CφHH
47
pF
Capacitance between reset gate clock and GND
CφRG
11
pF
Capacitance between substrate clock and GND
CφSUB
680
pF
R1, R3
91
Ω
R2, R4
100
Ω
RGND
68
Ω
Capacitance between vertical transfer clock
and GND
Capacitance between vertical transfer clocks
Vertical transfer clock series resistor
Vertical transfer clock ground resistor
Vφ2
Vφ1
CφV12
R1
R2
Hφ1
CφV1
CφV23
CφV4
Vφ4
Hφ2
CφHH
CφV2
CφV41
R4
Remarks
RGND
CφV34
CφH1
CφH2
CφV3
R3
Vφ3
Vertical transfer clock equivalent circuit
Horizontal transfer clock equivalent circuit
–7–
ICX418AKB
Drive Clock Waveform Conditions
(1) Readout clock waveform
100%
90%
VVT
φM
φM
2
10%
0%
tr
twh
0V
tf
(2) Vertical transfer clock waveform
Vφ1
Vφ3
VVH1
VVHH
VVH
VVHH
VVHL
VVHL
VVHL
VVL1
VVHH
VVHH
VVH3
VVH
VVHL
VVL3
VVLH
VVLH
VVLL
VVLL
VVL
VVL
Vφ2
Vφ4
VVHH
VVHH
VVH
VVH
VVHH
VVHH
VVHL
VVHL
VVH2 VVHL
VVH4
VVLH
VVL2VVLH
VVLL
VVLL
VVL4
VVL
VVH = (VVH1 + VVH2)/2
VVL = (VVL3 + VVL4)/2
VφV = VVHn – VVLn (n = 1 to 4)
VVHL
–8–
VVL
ICX418AKB
(3) Horizontal transfer clock waveform
tr
twh
tf
90%
VφH
twl
10%
VHL
tr
(4) Reset gate clock waveform
twh
tf
VRGH
twl
VφRG
Point A
RG waveform
VRGL + 0.5V
VRGLH
VRGL
VRGLL
VRGLm
Hφ1 waveform
+2.5V
VRGLH is the maximum value and VRGLL is the minimum value of the coupling waveform during the period from
Point A in the above diagram until the rising edge of RG. In addition, VRGL is the average value of VRGLH and
VRGLL.
VRGL = (VRGLH + VRGLL)/2
Assuming VRGH is the minimum value during the period twh, then:
VφRG = VRGH – VRGL
Negative overshoot level during the falling edge of RG is VRGLm.
(5) Substrate clock waveform
100%
90%
φM
VφSUB
φM
2
10%
VSUB
0%
tr
twh
–9–
tf
ICX418AKB
Clock Switching Characteristics
Item
Symbol
VT
Vertical transfer
clock
Vφ1, Vφ2,
Vφ3, Vφ4
Horizontal
transfer clock
Readout clock
During
imaging
twh
2.3 2.5
φSUB
tf
0.5
0.5
20
20
15
5.38
19
Remarks
Unit
µs During readout
250 ns ∗1
15
During
Hφ1
parallel-serial
Hφ2
conversion
Substrate clock
tr
Min. Typ. Max. Min. Typ. Max. Min. Typ. Max. Min. Typ. Max.
Hφ
Reset gate clock φRG
twl
15
0.01
0.01
5.38
0.01
0.01
51
3
3
19
ns
∗2
µs
11
13
1.5 1.8
0.5
ns
0.5 µs
∗1 When vertical transfer clock driver CXD1267AN is used.
∗2 tf ≥ tr – 2ns.
Item
Symbol
Horizontal transfer clock
Hφ1, Hφ2
two
Min.
Typ.
16
20
Max.
Unit Remarks
ns
∗3
∗3 The overlap period for twh and twl of horizontal transfer clocks Hφ1 and Hφ2 is two.
– 10 –
When draining
charge
ICX418AKB
Image Sensor Characteristics
(Ta = 25°C)
Unit
Measurement
method
mV
1
mV
2
–105
dB
3
20
%
4
Zone 0 and I
25
%
4
Zone 0 to II'
∆Sr
10
%
5
∆Sb
10
%
5
Dark signal
Ydt
2
mV
6
Ta = 60°C
Dark signal shading
∆Ydt
1
mV
7
Ta = 60°C
Flicker Y
Fy
2
%
8
Flicker R-Y
Fcr
5
%
8
Flicker B-Y
Fcb
5
%
8
Line crawl R
Lcr
3
%
9
Line crawl G
Lcg
3
%
9
Line crawl B
Lcb
3
%
9
Line crawl W
Lcw
3
%
9
Lag
Lag
0.5
%
10
Item
Symbol
Min.
Typ.
Sensitivity
S
1040
1300
Saturation signal
Ysat
1000
Smear
Sm
Video signal shading
SHy
Uniformity between
video signal channels
–115
Max.
Remarks
Ta = 60°C
Zone Definition of Video Signal Shading
768 (H)
14
14
12
H
8
V
10
H
8
Zone 0, I
494 (V)
10
Zone II, II'
V
10
Ignored region
Effective pixel region
Measurement System
[∗A]
CCD signal output
LPF1
[∗Y]
Y signal output
(3dB down 6.3MHz)
CCD
C.D.S
AMP
[∗C]
S/H
LPF2
S/H
Chroma signal output
(3dB down 1MHz)
Note) Adjust the amplifier gain so that the gain between [∗A] and [∗Y], and between [∗A] and [∗C] equals 1.
– 11 –
ICX418AKB
Image Sensor Characteristics Measurement Method
Measurement conditions
1) In the following measurements, the device drive conditions are at the typical values of the bias and clock
voltage conditions. (when used with substrate bias external adjustment, set the substrate voltage to the
value indicated on the device.)
2) In the following measurements, spot blemishes are excluded and, unless otherwise specified, the optical
black level (OB) is used as the reference for the signal output, which is taken as the value of Y signal output
or chroma signal output of the measurement system.
Color coding of this image sensor & Composition of luminance (Y) and chroma (color difference) signals
Cy
Ye
Cy
Ye
A1
G
Mg
G
Mg
Cy
Ye
Cy
Ye
Mg
G
Mg
G
B
A2
As shown in the left figure, fields are read out. The charge is
mixed by pairs such as A1 and A2 in the A field. (pairs such
as B in the B field)
As a result, the sequence of charges output as signals from
the horizontal shift register (Hreg) is, for line A1, (G + Cy),
(Mg + Ye), (G + Cy), and (Mg + Ye).
Hreg
Color Coding Diagram
These signals are processed to form the Y signal and chroma (color difference) signal. The Y signal is formed
by adding adjacent signals, and the chroma signal is formed by subtracting adjacent signals. In other words,
the approximation:
Y = {(G + Cy) + (Mg + Ye)} × 1/2
= 1/2 {2B + 3G + 2R}
is used for the Y signal, and the approximation:
R – Y = {(Mg + Ye) – (G + Cy)}
= {2R – G}
is used for the chroma (color difference) signal. For line A2, the signals output from Hreg in sequence are
(Mg + Cy), (G + Ye), (Mg + Cy), (G + Ye).
The Y signal is formed from these signals as follows:
Y = {(G + Ye) + (Mg + Cy)} × 1/2
= 1/2 {2B + 3G + 2R}
This is balanced since it is formed in the same way as for line A1.
In a like manner, the chroma (color difference) signal is approximated as follows:
– (B – Y) = {(G + Ye) – (Mg + Cy)}
= – {2B – G}
In other words, the chroma signal can be retrieved according to the sequence of lines from R – Y and – (B – Y)
in alternation. This is also true for the B field.
– 12 –
ICX418AKB
Definition of standard imaging conditions
1) Standard imaging condition I:
Use a pattern box (luminance 706cd/m2, color temperature of 3200K halogen source) as a subject. (Pattern
for evaluation is not applicable.) Use a testing standard lens with CM500S (t = 1.0mm) as an IR cut filter and
image at F5.6. The luminous intensity to the sensor receiving surface at this point is defined as the standard
sensitivity testing luminous intensity.
2) Standard imaging condition II:
Image a light source (color temperature of 3200K) with a uniformity of brightness within 2% at all angles.
Use a testing standard lens with CM500S (t = 1.0mm) as an IR cut filter. The luminous intensity is adjusted
to the value indicated in each testing item by the lens diaphragm.
1. Sensitivity
Set to standard imaging condition I. After selecting the electronic shutter mode with a shutter speed of
1/250s, measure the Y signal (Ys) at the center of the screen and substitute the value into the following
formula.
S = Ys ×
250
[mV]
60
2. Saturation signal
Set to standard imaging condition II. After adjusting the luminous intensity to 10 times the intensity with
average value of the Y signal output, 200mV, measure the minimum value of the Y signal.
3. Smear
Set to standard imaging condition II. With the lens diaphragm at F5.6 to F8, adjust the luminous intensity to
500 times the intensity with average value of the Y signal output, 200mV. When the readout clock is
stopped and the charge drain is executed by the electronic shutter at the respective H blankings, measure
the maximum value YSm [mV] of the Y signal output and substitute the value into the following formula.
Sm = 20 × log
YSm × 1 ×
500
200
1
10
[dB] (1/10V method conversion value)
4. Video signal shading
Set to standard imaging condition II. With the lens diaphragm at F5.6 to F8, adjust the luminous intensity so
that the average value of the Y signal output is 200mV. Then measure the maximum (Ymax [mV]) and
minimum (Ymin [mV]) values of the Y signal and substitute the values into the following formula.
SHy = (Ymax – Ymin)/200 × 100 [%]
5. Uniformity between video signal channels
Set to standard imaging condition II. Adjust the luminous intensity so that the average value of the Y signal
output is 200mV, and then measure the maximum (Crmax, Cbmax [mV]) and minimum (Crmin, Cbmin
[mV]) values of the R – Y and B – Y channels of the chroma signal and substitute the values into the
following formula.
∆Sr = | (Crmax – Crmin)/200 | × 100 [%]
∆Sb = | (Cbmax – Cbmin)/200 | × 100 [%]
6. Dark signal
Measure the average value of the Y signal output (Ydt [mV]) with the device ambient temperature 60°C and
the device in the light-obstructed state, using the horizontal idle transfer level as a reference.
– 13 –
ICX418AKB
7. Dark signal shading
After measuring 6, measure the maximum (Ydmax [mV]) and minimum (Ydmin [mV]) values of the dark
signal output and substitute the values into the following formula.
∆Ydt = Ydmax – Ydmin [mV]
8. Flicker
1) Fy
Set to standard imaging condition II. Adjust the luminous intensity so that the average value of the Y signal
output is 200mV, and then measure the difference in the signal level between fields (∆Yf [mV]). Then
substitute the value into the following formula.
Fy = (∆Yf/200) × 100 [%]
2) Fcr, Fcb
Set to standard imaging condition II. Adjust the luminous intensity so that the average value of the Y signal
output is 200mV, insert an R or B filter, and then measure both the difference in the signal level between
fields of the chroma signal (∆Cr, ∆Cb) as well as the average value of the chroma signal output (CAr, CAb).
Substitute the values into the following formula.
Fci = (∆Ci/CAi) × 100 [%] (i = r, b)
9. Line crawls
Set to standard imaging condition II. Adjust the luminous intensity so that the average value of the Y signal
output is 200mV, and then insert a white subject and R, G, and B filters and measure the difference
between Y signal lines for the same field (∆Ylw, ∆Ylr, ∆Ylg, ∆Ylb [mV]). Substitute the values into the
following formula.
Lci = (∆Yli/200) × 100 [%] (i = w, r, g, b)
10. Lag
Adjust the Y signal output value generated by strobe light to 200mV. After setting the strobe light so that it
strobes with the following timing, measure the residual signal (Ylag). Substitute the value into the following
formula.
Lag = (Ylag/200) × 100 [%]
FLD
V1
Light
Strobe light
timing
Y signal output 200mV
Output
– 14 –
Ylag (lag)
12
11
8
9
10
XV3
XSG2
XV4
RG
Hφ2
Hφ1
13
7
XSG1
22/20V
14
6
XV1
15
16
5
XV2
CXD1267AN
17
4
XSUB
22/16V
1/35V
0.01
15
2
16
1
Vφ4
Hφ2
18
Vφ3
Hφ1
3
100k
3
4
5
8
9
7
10
6
ICX418
(BOTTOM VIEW)
Vφ2
14
VDSUB
19
φSUB
13
φRG
20
VL
2
Vφ1
12
RD
– 15 –
3.9k
100
0.01
11
GND
1
VDD
NC
15V
VOUT
NC
Drive Circuit 1 (substrate bias internal generation mode)
3.3/20V
1
0.01
[∗A]
CCD OUT
1M
3.3/16V
–9V
ICX418AKB
13
12
11
7
8
9
10
XSG1
XV3
XSG2
XV4
RG
Hφ2
Hφ1
14
6
XV1
22/20V
16
5
XV2
15
17
4
XSUB
CXD1267AN
18
3
22/16V
1/35V
1/35V
0.01
1/35V
15
2
16
1
56k
14
13
12
3.9k
100
0.01
9
10
8
39k
11
7
6
5
0.1
ICX418
(BOTTOM VIEW)
4
3
100k 27k
Vφ4
Hφ2
19
Vφ3
Hφ1
20
Vφ2
VDSUB
2
RD
1
φSUB
φRG
270k
Vφ1
GND
0.1
VL
NC
15V
VDD
VOUT
– 16 –
NC
Drive Circuit 2 (substrate bias external adjustment mode)
3.3/20V
0.1
15k
47k
15k
0.01
[∗A]
CCD OUT
1M
3.3/16V
–9V
ICX418AKB
ICX418AKB
Spectral Sensitivity Characteristics (Excludes lens characteristics and light source characteristics)
1.0
Cy
Ye
0.8
Relative Response
G
0.6
0.4
Mg
0.2
0
400
450
500
550
Wave Length [nm]
600
650
700
Sensor Readout Clock Timing Chart
V1
2.5
V2
Odd Field
V3
V4
33.5
1.6
2.5 2.5 2.5
0.2
V1
V2
Even Field
V3
V4
Unit: µs
– 17 –
– 18 –
CCD
OUT
V4
V3
V2
V1
HD
BLK
VD
FLD
493
494
525
1
2
3
4
5
520
Drive Timing Chart (Vertical Sync)
10
2 4 6
1 3 5
15
2 4 6
1 3 5
494
493
1 3 5
2 4 6
1 3 5
2 4 6
ICX418AKB
280
275
270
265
260
20
– 19 –
SUB
V4
V3
V2
V1
RG
H2
H1
BLK
HD
20
10
768
1
2
3
5
760
Drive Timing Chart (Horizontal Sync)
ICX418AKB
20
10
20
22
1
2
3
1
2
3
10
1
2
3
5
40
30
ICX418AKB
Notes on Handling
1) Static charge prevention
CCD image sensors are easily damaged by static discharge. Before handling be sure to take the following
protective measures.
a) Either handle bare handed or use non-chargeable gloves, clothes or material.
Also use conductive shoes.
b) When handling directly use an earth band.
c) Install a conductive mat on the floor or working table to prevent the generation of static electricity.
d) Ionized air is recommended for discharge when handling CCD image sensor.
e) For the shipment of mounted substrates, use boxes treated for the prevention of static charges.
2) Soldering
a) Make sure the package temperature does not exceed 80°C.
b) Solder dipping in a mounting furnace causes damage to the glass and other defects. Use a ground 30W
soldering iron and solder each pin in less than 2 seconds. For repairs and remount, cool sufficiently.
c) To dismount an image sensor, do not use a solder suction equipment. When using an electric desoldering
tool, use a thermal controller of the zero cross On/Off type and connect it to ground.
3) Dust and dirt protection
Image sensors are packed and delivered by taking care of protecting its glass plates from harmful dust and
dirt. Clean glass plates with the following operations as required, and use them.
a) Perform all assembly operations in a clean room (class 1000 or less).
b) Do not either touch glass plates by hand or have any object come in contact with glass surfaces. Should
dirt stick to a glass surface, blow it off with an air blower. (For dirt stuck through static electricity ionized
air is recommended.)
c) Clean with a cotton bud and ethyl alcohol if grease stained. Be careful not to scratch the glass.
d) Keep in a case to protect from dust and dirt. To prevent dew condensation, preheat or precool when
moving to a room with great temperature differences.
e) When a protective tape is applied before shipping, just before use remove the tape applied for electrostatic
protection. Do not reuse the tape.
4) Do not expose to strong light (sun rays) for long periods, as color filters will be discolored. When high luminous
objects are imaged with the exposure level control by the electronic-iris, the luminance of the image-plane
may become excessive and discolor of the color filter will possibly be accelerated. In such a case, it is advisable that taking-lens with the automatic-iris and closing of the shutter during the power-off mode should be
properly arranged. For continuous using under cruel condition exceeding the normal using condition, consult
our company.
5) Exposure to high temperature or humidity will affect the characteristics. Accordingly avoid storage or usage in
such conditions.
6) CCD image sensors are precise optical equipment that should not be subject to too much mechanical shocks.
– 20 –
– 21 –
1.5
~
B'
1st. pin Index
B
1.27
0.6
42 ALLOY
0.90g
AS-B4-01(E)
LEAD MATERIAL
PACKAGE MASS
DRAWING NUMBER
GOLD PLATING
LEAD TREATMENT
~
0.7
~
Ceramic
1.5
12.35 ± 0.3
12.0 ± 0.15
6.175
H
PACKAGE MATERIAL
1
V
3
0.
±
2
3.
1
16
φ
1.84
PACKAGE STRUCTURE
1.84
1.5
8
0.3
9
6.175
1.0
A
0.3
12.35 ± 0.3
M
C
8
9
~
7.62
0.25
4.0
∗ Center of the package : The center is halfway between two pairs of opposite sides,
as measured from “B”, “B'”.
8. The thickness of the cover glass is 0.75mm, and the refractive index is 1.5.
7. The tilt of the effective image area relative to the bottom “C” is less than 60µm.
6. The height from the bottom “C” to the effective image area is 1.41 ± 0.15mm.
5. The rotation angle of the effective image area relative to H and V is ± 1˚.
4. The center of the effective image area relative to the center of the package (∗)
is (H, V) = (0, 0) ± 0.15mm.
3. The bottom “C” of the package is the height reference.
2. The point “B” of the package is the horizontal reference.
The point “B'” of the package is the vertical reference.
1
16
4.0
1. “A” is the center of the effective image area.
2.54
3.29 ± 0.3
16 pin DIP (300mil)
12.0 ± 0.15
4.0 ± 0.2
Unit: mm
~
Package Outline
ICX418AKB
Sony Corporation