CYPRESS CY7B991-7JI

92
CY7B991
CY7B992
Programmable Skew Clock Buffer
Features
functions. These multiple-output clock drivers provide the system integrator with functions necessary to optimize the timing
of high-performance computer systems. Eight individual drivers, arranged as four pairs of user-controllable outputs, can
each drive terminated transmission lines with impedances as
low as 50Ω while delivering minimal and specified output skews
and full-swing logic levels (CY7B991 TTL or CY7B992 CMOS).
• All output pair skew <100 ps typical (250 max.)
• 3.75- to 80-MHz output operation
• User-selectable output functions
— Selectable skew to 18 ns
— Inverted and non-inverted
Each output can be hardwired to one of nine delay or function
configurations. Delay increments of 0.7 to 1.5 ns are determined by the operating frequency with outputs able to skew up
to ±6 time units from their nominal “zero” skew position. The completely integrated PLL allows external load and transmission line
delay effects to be canceled. When this “zero delay” capability of the
PSCB is combined with the selectable output skew functions, the
user can create output-to-output delays of up to ±12 time units.
— Operation at 1⁄2 and 1⁄4 input frequency
•
•
•
•
•
•
•
— Operation at 2x and 4x input frequency (input as low
as 3.75 MHz)
Zero input to output delay
50% duty-cycle outputs
Outputs drive 50Ω terminated lines
Low operating current
32-pin PLCC/LCC package
Jitter < 200 ps peak-to-peak (< 25 ps RMS)
Compatible with a Pentium™-based processor
Divide-by-two and divide-by-four output functions are provided
for additional flexibility in designing complex clock systems.
When combined with the internal PLL, these divide functions
allow distribution of a low-frequency clock that can be multiplied by two or four at the clock destination. This facility minimizes clock distribution difficulty while allowing maximum system clock speed and flexibility.
Functional Description
The CY7B991 and CY7B992 Programmable Skew Clock Buffers (PSCB) offer user-selectable control over system clock
Logic Block Diagram
Pin Configuration
TEST
GND
32 31 30
29
2F1
REF
1
2F0
4F0
6
28
GND
4F1
7
27
1F1
VCCQ
8
26
1F0
25
VCCN
4Q1
SELECT
2Q0
MATRIX
1Q0
1F0
1F1
9
4Q1
10
24
1Q0
4Q0
11
23
1Q1
GND
12
22
GND
GND
13
21
14 15 16 17 18 19 20
GND
3Q1
2Q1
VCCN
2Q0
3Q0
CY7B991
CY7B992
2Q1
SKEW
3Q1
2F0
2F1
2
VCCN
SELECT
INPUTS
(THREE
LEVEL)
3
5
FB
3F0
3F1
4Q0
4
3F1
VCCN
4F0
4F1
VCCQ
FS
FS
VCO AND
TIME UNIT
GENERATOR
3F0
REF
FILTER
3Q0
PHASE
FREQ
DET
FB
TEST
PLCC/LCC
7B991–2
1Q1
7B991–1
Pentium is a trademark of Intel Corporation.
Cypress Semiconductor Corporation
Document #: 38-07138 Rev. **
•
3901 North First Street
•
San Jose
•
CA 95134 • 408-943-2600
Revised September 26, 2001
CY7B991
CY7B992
Pin Definitions
Signal
Name
I/O
Description
REF
I
Reference frequency input. This input supplies the frequency and timing against which all functional
variation is measured.
FB
I
PLL feedback input (typically connected to one of the eight outputs).
FS
I
Three-level frequency range select. See Table 1.
1F0, 1F1
I
Three-level function select inputs for output pair 1 (1Q0, 1Q1). See Table 2.
2F0, 2F1
I
Three-level function select inputs for output pair 2 (2Q0, 2Q1). See Table 2.
3F0, 3F1
I
Three-level function select inputs for output pair 3 (3Q0, 3Q1). See Table 2.
4F0, 4F1
I
Three-level function select inputs for output pair 4 (4Q0, 4Q1). See Table 2.
TEST
I
Three-level select. See test mode section under the block diagram descriptions.
1Q0, 1Q1
O
Output pair 1. See Table 2.
2Q0, 2Q1
O
Output pair 2. See Table 2.
3Q0, 3Q1
O
Output pair 3. See Table 2.
4Q0, 4Q1
O
Output pair 4. See Table 2.
VCCN
PWR
Power supply for output drivers.
VCCQ
PWR
Power supply for internal circuitry.
GND
PWR
Ground.
Block Diagram Description
Phase Frequency Detector and Filter
These two blocks accept inputs from the reference frequency
(REF) input and the feedback (FB) input and generate correction information to control the frequency of the Voltage-Controlled Oscillator (VCO). These blocks, along with the VCO,
form a Phase-Locked Loop (PLL) that tracks the incoming
REF signal.
(xF0, xF1) inputs. Table 2 below shows the nine possible output functions for each section as determined by the function
select inputs. All times are measured with respect to the REF
input assuming that the output connected to the FB input has
0tU selected.
Table 2. Programmable Skew Configurations[1]
Function Selects
Output Functions
1F1, 2F1,
3F1, 4F1
1F0, 2F0,
3F0, 4F0
The VCO accepts analog control inputs from the PLL filter
block and generates a frequency that is used by the time unit
generator to create discrete time units that are selected in the
skew select matrix. The operational range of the VCO is determined by the FS control pin. The time unit (tU) is determined
by the operating frequency of the device and the level of the
FS pin as shown in Table 1.
LOW
LOW
–4tU
LOW
MID
–3tU
–6tU
–6tU
LOW
HIGH
–2tU
–4tU
–4tU
MID
LOW
–1tU
–2tU
–2tU
MID
MID
0tU
0tU
0tU
MID
HIGH
+1tU
+2tU
+2tU
Table 1. Frequency Range Select and tU Calculation[1]
HIGH
LOW
+2tU
+4tU
+4tU
HIGH
MID
+3tU
+6tU
+6tU
VCO and Time Unit Generator
fNOM (MHz)
FS[2, 3] Min. Max.
1
t U = -----------------------f NOM × N
where N =
Approximate
Frequency (MHz) At
Which tU = 1.0 ns
LOW
15
30
44
22.7
MID
25
50
26
38.5
HIGH
40
80
16
62.5
Skew Select Matrix
The skew select matrix is comprised of four independent sections. Each section has two low-skew, high-fanout drivers
(xQ0, xQ1), and two corresponding three-level function select
Document #: 38-07138 Rev. **
1Q0, 1Q1,
2Q0, 2Q1
3Q0, 3Q1
4Q0, 4Q1
Divide by 2 Divide by 2
HIGH
HIGH
+4tU
Divide by 4 Inverted
Notes:
1. For all three-state inputs, HIGH indicates a connection to VCC, LOW
indicates a connection to GND, and MID indicates an open connection.
Internal termination circuitry holds an unconnected input to VCC/2.
2. The level to be set on FS is determined by the “normal” operating frequency (fNOM) of the VCO and Time Unit Generator (see Logic Block
Diagram). Nominal frequency (fNOM) always appears at 1Q0 and the
other outputs when they are operated in their undivided modes (see
Table 2). The frequency appearing at the REF and FB inputs will be fNOM
when the output connected to FB is undivided. The frequency of the REF
and FB inputs will be fNOM/2 or fNOM/4 when the part is configured for a
frequency multiplication by using a divided output as the FB input.
3. When the FS pin is selected HIGH, the REF input must not transition
upon power-up until VCC has reached 4.3V.
Page 2 of 15
U
U
U
U
U
U
t 0 +1t
t 0 +2t
t 0 +3t
t 0 +4t
t 0 +5t
t 0 +6t
t0
t 0 – 1t U
t 0 – 2t U
t 0 – 3t U
t 0 – 4t U
t 0 – 5t U
t 0 – 6t U
CY7B991
CY7B992
FBInput
REFInput
1Fx
2Fx
3Fx
4Fx
(N/A)
LM
– 6t U
LL
LH
– 4t U
LM
(N/A)
– 3t U
LH
ML
– 2t U
ML
(N/A)
– 1t U
MM
MM
MH
(N/A)
+1t U
HL
MH
+2t U
HM
(N/A)
+3t U
HH
HL
+4t U
0tU
+6t U
(N/A)
HM
(N/A)
LL/HH
DIVIDED
(N/A)
HH
INVERT
7B991–3
Figure 1. Typical Outputs with FB Connected to a Zero-Skew Output[4]
Test Mode
Ambient Temperature with
Power Applied ............................................ –55°C to +125°C
The TEST input is a three-level input. In normal system operation, this pin is connected to ground, allowing the
CY7B991/CY7B992 to operate as explained briefly above (for
testing purposes, any of the three-level inputs can have a removable jumper to ground, or be tied LOW through a 100Ω
resistor. This will allow an external tester to change the state
of these pins.)
Supply Voltage to Ground Potential ...............–0.5V to +7.0V
If the TEST input is forced to its MID or HIGH state, the device
will operate with its internal phase locked loop disconnected,
and input levels supplied to REF will directly control all outputs.
Relative output to output functions are the same as in normal
mode.
Latch-Up Current..................................................... >200 mA
In contrast with normal operation (TEST tied LOW). All outputs
will function based only on the connection of their own function
select inputs (xF0 and xF1) and the waveform characteristics
of the REF input.
Maximum Ratings
(Above which the useful life may be impaired. For user guidelines, not tested.)
DC Input Voltage ............................................–0.5V to +7.0V
Output Current into Outputs (LOW)............................. 64 mA
Static Discharge Voltage ........................................... >2001V
(per MIL-STD-883, Method 3015)
Operating Range
Range
Ambient
Temperature
VCC
Commercial
0°C to +70°C
5V ± 10%
–40°C to +85°C
5V ± 10%
–55°C to +125°C
5V ± 10%
Industrial
[5]
Military
Notes:
4. FB connected to an output selected for “zero” skew (i.e., xF1 = xF0 =
MID).
5. Indicates case temperature.
Storage Temperature .................................–65°C to +150°C
Document #: 38-07138 Rev. **
Page 3 of 15
CY7B991
CY7B992
Electrical Characteristics Over the Operating Range[6]
CY7B991
Parameter
Description
Test Conditions
VCC = Min., IOH = –16 mA
Min.
Max.
CY7B992
Min.
Max.
2.4
Unit
VOH
Output HIGH Voltage
V
VOL
Output LOW Voltage
VIH
Input HIGH Voltage
(REF and FB inputs only)
2.0
VCC
VCC –
1.35
VCC
V
VIL
Input LOW Voltage
(REF and FB inputs only)
–0.5
0.8
–0.5
1.35
V
VIHH
Three-Level Input HIGH
Voltage (Test, FS, xFn)[7]
Min. ≤ VCC ≤ Max.
VCC – 0.85
VCC
VCC – 0.85
VCC
V
VIMM
Three-Level Input MID
Voltage (Test, FS, xFn)[7]
Min. ≤ VCC ≤ Max.
VCC/2 –
500 mV
VCC/2 +
500 mV
VCC/2 –
500 mV
VCC/2 +
500 mV
V
VILL
Three-Level Input LOW
Voltage (Test, FS, xFn)[7]
Min. ≤ VCC ≤ Max.
0.0
0.85
0.0
0.85
V
IIH
Input HIGH Leakage Current
(REF and FB inputs only)
VCC = Max., VIN = Max.
10
µA
IIL
Input LOW Leakage Current
(REF and FB inputs only)
VCC = Max., VIN = 0.4V
IIHH
Input HIGH Current
(Test, FS, xFn)
VIN = VCC
IIMM
Input MID Current
(Test, FS, xFn)
VIN = VCC/2
IILL
Input LOW Current
(Test, FS, xFn)
VIN = GND
IOS
Output Short Circuit
Current[8]
VCC = Max., VOUT
= GND (25°C only)
ICCQ
Operating Current Used by
Internal Circuitry
VCCN = VCCQ =
Max., All Input
Selects Open
ICCN
Output Buffer Current per
Output Pair[9]
PD
Power Dissipation per
Output Pair[10]
VCC = Min., IOH =–40 mA
VCC –0.75
VCC = Min., IOL = 46 mA
0.45
V
VCC = Min., IOL = 46 mA
0.45
10
–500
µA
–500
200
µA
50
µA
–200
–200
µA
–250
N/A
mA
Com’l
85
85
mA
Mil/Ind
90
90
VCCN = VCCQ = Max.,
IOUT = 0 mA
Input Selects Open, fMAX
14
19
mA
VCCN = VCCQ = Max.,
IOUT = 0 mA
Input Selects Open, fMAX
78
104[11]
mW
200
–50
50
–50
Notes:
6. See the last page of this specification for Group A subgroup testing information.
7. These inputs are normally wired to VCC, GND, or left unconnected (actual threshold voltages vary as a percentage of VCC). Internal termination resistors hold
unconnected inputs at VCC/2. If these inputs are switched, the function and timing of the outputs may glitch and the PLL may require an additional tLOCK time
before all datasheet limits are achieved.
8. CY7B991 should be tested one output at a time, output shorted for less than one second, less than 10% duty cycle. Room temperature only. CY7B992 outputs
should not be shorted to GND. Doing so may cause permanent damage.
9. Total output current per output pair can be approximated by the following expression that includes device current plus load current:
CY7B991: ICCN = [(4 + 0.11F) + [((835 – 3F)/Z) + (.0022FC)]N] x 1.1
CY7B992: ICCN = [(3.5+ 0.17F) + [((1160 – 2.8F)/Z) + (.0025FC)]N] x 1.1
Where
F = frequency in MHz
C = capacitive load in pF
Z = line impedance in ohms
N = number of loaded outputs; 0, 1, or 2
FC = F < C
10. Total power dissipation per output pair can be approximated by the following expression that includes device power dissipation plus power dissipation due to
the load circuit:
CY7B991: PD = [(22 + 0.61F) + [((1550 – 2.7F)/Z) + (.0125FC)]N] x 1.1
CY7B992: PD = [(19.25+ 0.94F) + [((700 + 6F)/Z) + (.017FC)]N] x 1.1
See note 9 for variable definition.
11. CMOS output buffer current and power dissipation specified at 50-MHz reference frequency.
Document #: 38-07138 Rev. **
Page 4 of 15
CY7B991
CY7B992
Capacitance[12]
Parameter
Description
Test Conditions
Max.
Unit
Input Capacitance
TA = 25°C, f = 1 MHz, VCC = 5.0V
10
Note:
12. Applies to REF and FB inputs only. Tested initially and after any design or process changes that may affect these parameters.
CIN
pF
AC Test Loads and Waveforms
5V
R1
CL
R2
3.0V
R1=130
R2=91
CL = 50 pF (CL =30 pF for –2 and –5 devices)
(Includes fixture and probe capacitance)
2.0V
Vth =1.5V
0.8V
0.0V
2.0V
Vth =1.5V
0.8V
≤1ns
≤1ns
7B991–4
TTL AC Test Load (CY7B991)
7B991–5
TTL Input Test Waveform (CY7B991)
VCC
R1
CL
R1=100
R2=100
CL = 50 pF (CL =30 pF for –2 and –5 devices)
(Includes fixture and probe capacitance)
R2
7B991–6
VCC
80%
Vth = VCC/2
20%
0.0V
≤3ns
80%
Vth = VCC/2
20%
≤3ns
7B991–7
CMOS AC Test Load (CY7B992)
Document #: 38-07138 Rev. **
CMOS Input Test Waveform (CY7B992)
Page 5 of 15
CY7B991
CY7B992
Switching Characteristics Over the Operating Range[2, 13]
CY7B991–2[14]
Parameter
fNOM
Description
Operating Clock
Frequency in MHz
Min.
Max.
Min.
Max.
Unit
FS = LOW[1, 2]
15
30
15
30
MHz
FS = MID[1, 2]
25
50
25
50
40
80
40
80[15]
[1, 2 , 3]
FS = HIGH
Typ.
CY7B992–2[14]
Typ.
tRPWH
REF Pulse Width HIGH
5.0
5.0
ns
tRPWL
REF Pulse Width LOW
5.0
5.0
ns
tU
Programmable Skew Unit
tSKEWPR
Zero Output Matched-Pair Skew
(XQ0, XQ1)[16, 17]
0.05
0.20
0.05
0.20
ns
tSKEW0
Zero Output Skew (All Outputs)[16, 18,19]
0.1
0.25
0.1
0.25
ns
tSKEW1
Output Skew (Rise-Rise, Fall-Fall, Same
Class Outputs)[16, 20]
0.25
0.5
0.25
0.5
ns
tSKEW2
Output Skew (Rise-Fall, Nominal-Inverted,
Divided-Divided)[16, 20]
0.3
0.5
0.3
0.5
ns
tSKEW3
Output Skew (Rise-Rise, Fall-Fall, Different
Class Outputs)[16, 20]
0.25
0.5
0.25
0.5
ns
tSKEW4
Output Skew (Rise-Fall, Nominal-Divided,
Divided-Inverted)[16, 20]
0.5
0.9
0.5
0.7
ns
tDEV
Device-to-Device Skew[14, 21]
0.75
ns
tPD
Propagation Delay, REF Rise to FB Rise
–0.25
0.0
+0.25
–0.25
0.0
+0.25
ns
tODCV
Output Duty Cycle Variation[22]
–0.65
0.0
+0.65
–0.5
0.0
+0.5
ns
tPWH
tPWL
[23, 24]
2.0
3.0
ns
[23, 24]
1.5
3.0
ns
Output LOW Time Deviation from 50%
[23, 25]
Output Rise Time
tOFALL
Output Fall Time[23, 25]
tJR
0.75
Output HIGH Time Deviation from 50%
tORISE
tLOCK
See Table 1
PLL Lock Time
[26]
Cycle-to-Cycle Output
Jitter
[14]
RMS
[14]
Peak-to-Peak
0.15
1.0
1.2
0.5
2.0
2.5
ns
0.15
1.0
1.2
0.5
2.0
2.5
ns
0.5
0.5
ms
25
25
ps
200
200
ps
Note:
13. Test measurement levels for the CY7B991 are TTL levels (1.5V to 1.5V). Test measurement levels for the CY7B992 are CMOS levels (VCC/2 to VCC/2). Test
conditions assume signal transition times of 2 ns or less and output loading as shown in the AC Test Loads and Waveforms unless otherwise specified.
14. Guaranteed by statistical correlation. Tested initially and after any design or process changes that may affect these parameters.
15. Except as noted, all CY7B992–2 and –5 timing parameters are specified to 80-MHz with a 30-pF load.
16. SKEW is defined as the time between the earliest and the latest output transition among all outputs for which the same tU delay has been selected when all are
loaded with 50 pF and terminated with 50Ω to 2.06V (CY7B991) or VCC/2 (CY7B992).
17. tSKEWPR is defined as the skew between a pair of outputs (XQ0 and XQ1) when all eight outputs are selected for 0tU.
18. tSKEW0 is defined as the skew between outputs when they are selected for 0tU. Other outputs are divided or inverted but not shifted.
19. CL=0 pF. For CL=30 pF, tSKEW0=0.35 ns.
20. There are three classes of outputs: Nominal (multiple of tU delay), Inverted (4Q0 and 4Q1 only with 4F0 = 4F1 = HIGH), and Divided (3Qx and 4Qx only in Divide-by-2
or Divide-by-4 mode).
21. tDEV is the output-to-output skew between any two devices operating under the same conditions (VCC ambient temperature, air flow, etc.)
22. tODCV is the deviation of the output from a 50% duty cycle. Output pulse width variations are included in tSKEW2 and tSKEW4 specifications.
23. Specified with outputs loaded with 30 pF for the CY7B99X–2 and –5 devices and 50 pF for the CY7B99X–7 devices. Devices are terminated through 50Ω to
2.06V (CY7B991) or VCC/2 (CY7B992).
24. tPWH is measured at 2.0V for the CY7B991 and 0.8 VCC for the CY7B992. tPWL is measured at 0.8V for the CY7B991 and 0.2 VCC for the CY7B992.
25. tORISE and tOFALL measured between 0.8V and 2.0V for the CY7B991 or 0.8VCC and 0.2VCC for the CY7B992.
26. tLOCK is the time that is required before synchronization is achieved. This specification is valid only after VCC is stable and within normal operating limits. This parameter
is measured from the application of a new signal or frequency at REF or FB until tPD is within specified limits.
Document #: 38-07138 Rev. **
Page 6 of 15
CY7B991
CY7B992
Switching Characteristics Over the Operating Range[2, 13] (continued)
CY7B991–5
Parameter
fNOM
Description
Operating Clock
Frequency in MHz
Min.
FS = LOW
FS = MID
[1, 2]
[1, 2]
FS = HIGH
[1, 2 , 3]
Typ.
CY7B992–5
Max.
Min.
15
30
25
40
Typ.
Max.
Unit
15
30
MHz
50
25
50
80
40
80[15]
tRPWH
REF Pulse Width HIGH
5.0
5.0
ns
tRPWL
REF Pulse Width LOW
5.0
5.0
ns
tU
Programmable Skew Unit
tSKEWPR
Zero Output Matched-Pair Skew
(XQ0, XQ1)[16, 17]
0.1
0.25
0.1
0.25
ns
tSKEW0
Zero Output Skew (All Outputs)[16, 18]
0.25
0.5
0.25
0.5
ns
tSKEW1
Output Skew (Rise-Rise, Fall-Fall, Same
Class Outputs)[16, 20]
0.6
0.7
0.6
0.7
ns
tSKEW2
Output Skew (Rise-Fall, Nominal-Inverted,
Divided-Divided)[16, 20]
0.5
1.0
0.6
1.5
ns
tSKEW3
Output Skew (Rise-Rise, Fall-Fall, Different
Class Outputs)[16, 20]
0.5
0.7
0.5
0.7
ns
tSKEW4
Output Skew (Rise-Fall, Nominal-Divided,
Divided-Inverted)[16, 20]
0.5
1.0
0.6
1.7
ns
tDEV
Device-to-Device Skew[14, 21]
1.25
ns
tPD
Propagation Delay, REF Rise to FB Rise
tODCV
tPWH
tPWL
tORISE
tOFALL
tLOCK
tJR
See Table 1
Output Duty Cycle Variation
1.25
[22]
–0.5
0.0
+0.5
–0.5
0.0
+0.5
ns
–1.0
0.0
+1.0
–1.2
0.0
+1.2
ns
[23, 24]
2.5
4.0
ns
[23, 24]
3
4.0
ns
Output HIGH Time Deviation from 50%
Output LOW Time Deviation from 50%
Output Rise Time
Output Fall Time
PLL Lock Time
[23, 25]
[23, 25]
[26]
Cycle-to-Cycle Output
Jitter
Document #: 38-07138 Rev. **
[14]
RMS
Peak-to-Peak
[14]
0.15
1.0
1.5
0.5
2.0
3.5
ns
0.15
1.0
1.5
0.5
2.0
3.5
ns
0.5
0.5
ms
25
25
ps
200
200
ps
Page 7 of 15
CY7B991
CY7B992
Switching Characteristics Over the Operating Range[2, 13] (continued)
CY7B991–7
Parameter
fNOM
Description
Operating Clock
Frequency in MHz
Min.
FS = LOW
FS = MID
[1, 2]
[1, 2]
FS = HIGH[1, 2]
Typ.
CY7B992–7
Max.
Min.
Typ.
Max.
Unit
15
30
15
30
MHz
25
50
25
50
40
80
40
80[15]
tRPWH
REF Pulse Width HIGH
5.0
5.0
ns
tRPWL
REF Pulse Width LOW
5.0
5.0
ns
tU
Programmable Skew Unit
tSKEWPR
Zero Output Matched-Pair Skew
(XQ0, XQ1)[16, 17]
0.1
0.25
0.1
0.25
ns
tSKEW0
Zero Output Skew (All Outputs)[16, 18]
0.3
0.75
0.3
0.75
ns
tSKEW1
Output Skew (Rise-Rise, Fall-Fall, Same
Class Outputs)[16, 20]
0.6
1.0
0.6
1.0
ns
tSKEW2
Output Skew (Rise-Fall, Nominal-Inverted,
Divided-Divided)[16, 20]
1.0
1.5
1.0
1.5
ns
tSKEW3
Output Skew (Rise-Rise, Fall-Fall, Different
Class Outputs)[16, 20]
0.7
1.2
0.7
1.2
ns
tSKEW4
Output Skew (Rise-Fall, Nominal-Divided,
Divided-Inverted)[16, 20]
1.2
1.7
1.2
1.7
ns
tDEV
Device-to-Device Skew[14, 21]
1.65
ns
tPD
Propagation Delay, REF Rise to FB Rise
tODCV
See Table 1
1.65
[22]
Output Duty Cycle Variation
Output HIGH Time Deviation from 50%
tPWL
Output LOW Time Deviation from 50%[23, 24]
tOFALL
0.0
+0.7
–0.7
0.0
+0.7
ns
–1.2
0.0
+1.2
–1.5
0.0
+1.5
ns
3
5.5
ns
3.5
5.5
ns
[23, 24]
tPWH
tORISE
–0.7
[23, 25]
Output Rise Time
[23, 25]
Output Fall Time
[26]
tLOCK
PLL Lock Time
tJR
Cycle-to-Cycle Output
Jitter
Document #: 38-07138 Rev. **
RMS[14]
Peak-to-Peak
[14]
0.15
1.5
2.5
0.5
3.0
5.0
ns
0.15
1.5
2.5
0.5
3.0
5.0
ns
0.5
0.5
ms
25
25
ps
200
200
ps
Page 8 of 15
CY7B991
CY7B992
AC Timing Diagrams
tREF
tRPWL
tRPWH
REF
tODCV
tPD
tODCV
FB
tJR
Q
tSKEWPR,
tSKEW0,1
tSKEWPR,
tSKEW0,1
OTHER Q
tSKEW2
tSKEW2
INVERTED Q
tSKEW3,4
tSKEW3,4
tSKEW3,4
REF DIVIDED BY 2
tSKEW1,3, 4
tSKEW2,4
REF DIVIDED BY 4
7B991–8
Document #: 38-07138 Rev. **
Page 9 of 15
CY7B991
CY7B992
Operational Mode Descriptions
REF
LOAD
Z0
L1
SYSTEM
CLOCK
FB
REF
FS
LOAD
4F0
4F1
4Q0
4Q1
3F0
3F1
3Q0
3Q1
2F0
2F1
2Q0
2Q1
1F0
1F1
1Q0
1Q1
L2
Z0
LOAD
L3
Z0
L4
LOAD
TEST
Z0
LENGTH L1 = L2 = L3 = L4
7B991–9
Figure 2. Zero-Skew and/or Zero-Delay Clock Driver
Figure 2 shows the PSCB configured as a zero-skew clock
buffer. In this mode the 7B991/992 can be used as the basis
for a low-skew clock distribution tree. When all of the function
select inputs (xF0, xF1) are left open, the outputs are aligned
and may each drive a terminated transmission line to an independent load. The FB input can be tied to any output in this
configuration and the operating frequency range is selected
with the FS pin. The low-skew specification, coupled with the
ability to drive terminated transmission lines (with impedances
as low as 50 ohms), allows efficient printed circuit board design.
REF
SYS–
TEM
CLOCK
FB
REF
FS
4F0
4F1
LOAD
L1
Z0
LOAD
4Q0
4Q1
3F0
3F1
2F0
2F1
3Q0
3Q1
1F0
1F1
1Q0
1Q1
2Q0
2Q1
L2
Z0
LOAD
L3
Z0
L4
LOAD
TEST
LENGTH L1 = L2
L3 < L2 by 6 inches
L4 > L2 by 6 inches
Z0
7B991–10
Figure 3. Programmable-Skew Clock Driver
Figure 3 shows a configuration to equalize skew between metal traces of different lengths. In addition to low skew between
outputs, the PSCB can be programmed to stagger the timing
of its outputs. The four groups of output pairs can each be
programmed to different output timing. Skew timing can be
adjusted over a wide range in small increments with the appropriate strapping of the function select pins. In this configuration
the 4Q0 output is fed back to FB and configured for zero skew.
The other three pairs of outputs are programmed to yield different skews relative to the feedback. By advancing the clock
signal on the longer traces or retarding the clock signal on
shorter traces, all loads can receive the clock pulse at the
same time.
Document #: 38-07138 Rev. **
In this illustration the FB input is connected to an output with
0-ns skew (xF1, xF0 = MID) selected. The internal PLL synchronizes the FB and REF inputs and aligns their rising edges
to insure that all outputs have precise phase alignment.
Clock skews can be advanced by ±6 time units (tU) when using
an output selected for zero skew as the feedback. A wider range of
delays is possible if the output connected to FB is also skewed.
Since “Zero Skew”, +tU, and –tU are defined relative to output
groups, and since the PLL aligns the rising edges of REF and FB,
it is possible to create wider output skews by proper selection of the
xFn inputs. For example a +10 tU between REF and 3Qx can be
achieved by connecting 1Q0 to FB and setting 1F0 = 1F1 = GND,
Page 10 of 15
CY7B991
CY7B992
3F0 = MID, and 3F1 = High. (Since FB aligns at –4 tU and 3Qx
skews to +6 tU, a total of +10 tU skew is realized.) Many other configurations can be realized by skewing both the output used as the
FB input and skewing the other outputs.
REF
form at these outputs. Note that the 20- and 40-MHz clocks fall
simultaneously and are out of phase on their rising edge. This
will allow the designer to use the rising edges of the 1⁄2 frequency and 1⁄4 frequency outputs without concern for rising-edge skew. The 2Q0, 2Q1, 1Q0, and 1Q1 outputs run at
80 MHz and are skewed by programming their select inputs
accordingly. Note that the FS pin is wired for 80-MHz operation
because that is the frequency of the fastest output.
FB
REF
FS
REF
4F0
4F1
4Q0
4Q1
3F0
3F1
3Q0
3Q1
2F0
2F1
2Q0
2Q1
1F0
1F1
1Q0
1Q1
20 MHz
TEST
7B991–11
Figure 4. Inverted Output Connections
Figure 4 shows an example of the invert function of the PSCB.
In this example the 4Q0 output used as the FB input is programmed for invert (4F0 = 4F1 = HIGH) while the other three
pairs of outputs are programmed for zero skew. When 4F0 and
4F1 are tied high, 4Q0 and 4Q1 become inverted zero phase
outputs. The PLL aligns the rising edge of the FB input with the
rising edge of the REF. This causes the 1Q, 2Q, and 3Q outputs to become the “inverted” outputs with respect to the REF
input. By selecting which output is connect to FB, it is possible
to have 2 inverted and 6 non-inverted outputs or 6 inverted and
2 non-inverted outputs. The correct configuration would be determined by the need for more (or fewer) inverted outputs. 1Q,
2Q, and 3Q outputs can also be skewed to compensate for
varying trace delays independent of inversion on 4Q.
REF
20 MHz
FB
REF
FS
4F0
4F1
3F0
3F1
2F0
2F1
1F0
1F1
TEST
40 MHz
4Q0
4Q1
3Q0
3Q1
2Q0
2Q1
1Q0
1Q1
20 MHz
80 MHz
7B991–12
Figure 5. Frequency Multiplier with Skew Connections
Figure 5 illustrates the PSCB configured as a clock multiplier.
The 3Q0 output is programmed to divide by four and is fed
back to FB. This causes the PLL to increase its frequency until
the 3Q0 and 3Q1 outputs are locked at 20 MHz while the 1Qx
and 2Qx outputs run at 80 MHz. The 4Q0 and 4Q1 outputs are
programmed to divide by two, which results in a 40-MHz waveDocument #: 38-07138 Rev. **
FB
REF
FS
4F0
4F1
4Q0
4Q1
10 MHz
3F0
3F1
2F0
2F1
3Q0
3Q1
5 MHz
1F0
1F1
TEST
1Q0
1Q1
2Q0
2Q1
20 MHz
7B991–13
Figure 6. Frequency Divider Connections
Figure 6 demonstrates the PSCB in a clock divider application.
2Q0 is fed back to the FB input and programmed for zero skew.
3Qx is programmed to divide by four. 4Qx is programmed to
divide by two. Note that the falling edges of the 4Qx and 3Qx
outputs are aligned. This allows use of the rising edges of the
1
⁄2 frequency and 1⁄4 frequency without concern for skew
mismatch. The 1Qx outputs are programmed to zero skew and
are aligned with the 2Qx outputs. In this example, the FS input
is grounded to configure the device in the 15- to 30-MHz range
since the highest frequency output is running at 20 MHz.
Figure 7 shows some of the functions that are selectable on
the 3Qx and 4Qx outputs. These include inverted outputs and
outputs that offer divide-by-2 and divide-by-4 timing. An inverted output allows the system designer to clock different subsystems on opposite edges, without suffering from the pulse
asymmetry typical of non-ideal loading. This function allows
the two subsystems to each be clocked 180 degrees out of
phase, but still to be aligned within the skew spec.
The divided outputs offer a zero-delay divider for portions of
the system that need the clock to be divided by either two or
four, and still remain within a narrow skew of the “1X” clock.
Without this feature, an external divider would need to be added, and the propagation delay of the divider would add to the
skew between the different clock signals.
These divided outputs, coupled with the Phase Locked Loop,
allow the PSCB to multiply the clock rate at the REF input by
either two or four. This mode will enable the designer to distribute a low-frequency clock between various portions of the
system, and then locally multiply the clock rate to a more suitable frequency, while still maintaining the low-skew characteristics of the clock driver. The PSCB can perform all of the functions described above at the same time. It can multiply by two
and four or divide by two (and four) at the same time that it is
shifting its outputs over a wide range or maintaining zero skew
between selected outputs.
Page 11 of 15
CY7B991
CY7B992
REF
LOAD
Z0
20–MHz
DISTRIBUTION
CLOCK
80-MHz
INVERTED
FB
REF
FS
4F0
4F1
3F0
3F1
2F0
2F1
1F0
1F1
TEST
LOAD
4Q0
4Q1
3Q0
3Q1
2Q0
2Q1
1Q0
1Q1
20-MHz
Z0
LOAD
80-MHz
ZERO SKEW
80-MHz
SKEWED –3.125 ns (–4tU)
Z0
LOAD
Z0
7B991–14
Figure 7. Multi-Function Clock Driver
LOAD
REF
Z0
L1
FB
SYSTEM
CLOCK
REF
FS
4F0
4F1
LOAD
Z0
L2
4Q0
4Q1
3F0
3F1
2F0
2F1
3Q0
3Q1
1F0
1F1
1Q0
1Q1
LOAD
L3
2Q0
2Q1
Z0
L4
TEST
Z0
FB
REF
FS
4F0
4F1
3F0
3F1
2F0
2F1
1F0
1F1
TEST
4Q0
4Q1
3Q0
3Q1
2Q0
2Q1
1Q0
1Q1
LOAD
LOAD
7B991–15
Figure 8. Board-to-Board Clock Distribution
Figure 8 shows the CY7B991/992 connected in series to construct a zero-skew clock distribution tree between boards. Delays of the downstream clock buffers can be programmed to
compensate for the wire length (i.e., select negative skew
equal to the wire delay) necessary to connect them to the mas-
Document #: 38-07138 Rev. **
ter clock source, approximating a zero-delay clock tree. Cascaded clock buffers will accumulate low-frequency jitter because of the non-ideal filtering characteristics of the PLL filter.
It is recommended that not more than two clock buffers be
connected in series.
Page 12 of 15
CY7B991
CY7B992
Ordering Information
Accuracy
(ps)
Ordering Code
Package
Name
Package Type
Operating
Range
250
CY7B991–2JC
J65
32-Lead Plastic Leaded Chip Carrier
Commercial
500
CY7B991–5JC
J65
32-Lead Plastic Leaded Chip Carrier
Commercial
CY7B991–5JI
J65
32-Lead Plastic Leaded Chip Carrier
Industrial
CY7B991–7JC
J65
32-Lead Plastic Leaded Chip Carrier
Commercial
CY7B991–7JI
J65
32-Lead Plastic Leaded Chip Carrier
Industrial
750
CY7B991–7LMB
L55
32-Pin Rectangular Leadless Chip Carrier Military
250
CY7B992–2JC
J65
32-Lead Plastic Leaded Chip Carrier
Commercial
500
CY7B992–5JC
J65
32-Lead Plastic Leaded Chip Carrier
Commercial
CY7B992–5JI
J65
32-Lead Plastic Leaded Chip Carrier
Industrial
CY7B992–7JC
J65
32-Lead Plastic Leaded Chip Carrier
Commercial
CY7B992–7JI
J65
32-Lead Plastic Leaded Chip Carrier
Industrial
CY7B992–7LMB
L55
32-Pin Rectangular Leadless Chip Carrier Military
750
MILITARY SPECIFICATIONS
Group A Subgroup Testing
DC Characteristics
Parameter
Subgroups
VOH
1, 2, 3
VOL
1, 2, 3
VIH
1, 2, 3
VIL
1, 2, 3
VIHH
1, 2, 3
VIMM
1, 2, 3
VILL
1, 2, 3
IIH
1, 2, 3
IIL
1, 2, 3
IIHH
1, 2, 3
IIMM
1, 2, 3
IILL
1, 2, 3
ICCQ
1, 2, 3
ICCN
1, 2, 3
Document #: 38-07138 Rev. **
Page 13 of 15
CY7B991
CY7B992
Package Diagrams
32-Lead Plastic Leaded Chip Carrier
32-Pin Rectangular Leadless Chip Carrier
MIL-STD-1835 C-12
Document #: 38-07138 Rev. **
Page 14 of 15
© Cypress Semiconductor Corporation, 2001. The information contained herein is subject to change without notice. Cypress Semiconductor Corporation assumes no responsibility for the use
of any circuitry other than circuitry embodied in a Cypress Semiconductor product. Nor does it convey or imply any license under patent or other rights. Cypress Semiconductor does not authorize
its products for use as critical components in life-support systems where a malfunction or failure may reasonably be expected to result in significant injury to the user. The inclusion of Cypress
Semiconductor products in life-support systems application implies that the manufacturer assumes all risk of such use and in doing so indemnifies Cypress Semiconductor against all charges.
CY7B991
CY7B992
Document Title: CY7B991/CY7B992 Programmable Skew Clock Buffer (PSCB)
Document Number: 38-07138
REV.
ECN NO.
Issue
Date
Orig. of
Change
**
110247
12/19/01
SZV
Document #: 38-07138 Rev. **
Description of Change
Change from Spec number: 38-00513 to 38-07138
Page 15 of 15