ACE4000 3 Bay / 12 Kilowatt Power Shelf Features: • 3U High • Up to 12,000W in a 19” Rack • Single & Three Phase Input Models • Fits 3 Hot-Plug / N+1 Redundant Rectifiers • Current Sharing and Remote Sensing • World-wide safety approvals • Optional 1U Controller Available FEATURES BENEFITS KEY MARKETS & APPLICATIONS Single wire current sharing Provide system stress balancing and increases reliability Constant power characteristic Better suited for battery charging applications No Minimum Load Eliminates need for pre-load resistors. Reduces cost of ownership. Optional 1U High Controller Addresses telecom application requirements for redundant operation • Central Office • Telecom Access Nodes • Satellite Hubs • Broadband Switchers • XDSL Access Networks SPECIFICATIONS Rack Model Number Rectifier Module Part Number • Cellular Base Stations • Wireless • RF Amplifiers • PCS Installations • Factory Automation 12,000 Watt Power Shelf for CAR4000 Front End Modules ACE403 ACE403N ACE433 ACE433N CAR4010L1-1A CAR4010K1-1A CAR4010L1N-1A CAR4010K1N-1A CAR4030L1-1A CAR4030K1-1A CAR4030L1N-1A CAR4030K1N-1A Voltage Range +43.2~52.8 VDC +21.6~26.4 VDC -43.2~52.8 VDC -21.6~26.4 VDC +43.2~52.8 VDC +21.6~26.4 VDC -43.2~52.8 VDC -21.6~26.4 VDC Output Current 250A @ +48Vout 500A @ +24Vout 250A @ -48Vout 500A @ -24Vout 250A @ +48Vout 500A @ +24Vout 250A @ -48Vout 500A @ -24Vout Input Voltage Maximum Input Current (per module) Single Phase 180-264 VAC / 47-63 Hz Three Phase 180-264 VAC / 47-63 Hz 25A @ Full Load and 180 VAC Operation (per module) 15A per phase @ Full Load and 180 VAC Operation (per module) Maximum Output Power 12,000 Total Output Power (8,000 Watts Redundant Output Power) AC Input Feeds Individual Input Feeds for each rectifier for 4mm2 cable Input Protection Each CAR rectifier module is equipped with it's own internal fuse Efficiency 90% typical at 230VAC Regulation (Line & Load) +/- 0.5% of V1 Ripple & Noise 1% of V1 (pk-pk) - using 10µF tantalum cap. and 0.1µF ceramic cap. Load Sharing Single wire. +/- 5% of nominal current DC Bus Rectifiers connected in parallel. Floating bus with common "+". Maximum current is 250A Status Indicators DC Good and Temperature OK (Green), AC Good (Amber) Alarm Signals Over Temperature, Over/Under Voltage, No Power, Module not present Battery Interface RJ45 signal connector per rectifier. RS232 for programming via laptop (with Controller). Temperature Range 0 to 50°C at rated output power. Derates linearly to 60°C at 2.2% per °C Shock & Vibration Per MIL STD-810F, NEBS Compliant to GR 63 Core EMI / EMC Meets EN61000-3-2, -3 CISPR22 and FCC Part 15 Class A, Bellcore GR-1089-Core Safety Approvals UL: 478, 1012, 1950; CSA 22.2 No. 650; IEC: 380, 435, 950; VDE: 0804, 0806; & CE Mark (LVD) Dimensions Chassis Measures 18.00”/457.2mm (depth) x 17.165”/436.0mm (width) x 5.12”/132.1mm (height) rev 100506 www.lineagepower.com/oem Lineage Power Lineage Power Lineage Power (China) 3000 Skyline Dr. Mesquite, TX 75149 Phone: (972) 284-2000 2841 Dow Avenue Tustin, CA 92780 USA Phone: (714) 544-6665 1353 Chenqiao Road, Shanghai Sengpu Industrial Park Shanghai, 201401 China Phone: 021 6710 8910 ACE4000 3 Bay / 12 Kilowatt Power Shelf 18.00 (457.2) Outline Drawing 18.00 (457.2) Status / Control Connector 37 Pin D-Sub Connector PIN 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 17.165 (436) V1 FUNCTION 5vsbrtn Temp.Ok1 PGood1 AcFail1 Present1 On/Off1 5vsbrtn Temp.Ok2 PGood2 AcFail2 Present2 On/Off2 5vsbrtn Temp.Ok3 PGood3 AcFail3 Present3 On/Off3 N/C N/C N/C N/C N/C N/C V1 Sense RTN Sense Margin 1 Margin 2 N/C I-Share RTN N/C 5vsbrtn 5vsbrtn 5Vsb 5Vsb N/C 18.00 (457.2) 18.00 (457.2) 17.165 (436) RTN V1 5.18 (131.6) 5.18 (131.6) L1 L2 L3 FRONT END POWER SHELVES (POSITIVE POLARITY) RTN - V1 + 17.165 (436) RTN 5.18 (131.6) V1 5.18 (131.6) 5.18 (131.6) L1 L2 L3 V1 RETURN FRONT END POWER SHELVES (NEGATIVE POLARITY) L1 L2 L3 FRONT END POWER SHELVES (POSITIVE POLARITY) ELECOM SHELVES RTN - V1 5.18 (131.6) + L1 L2 L3 FRONT END POWER SHELVES (NEGATIVE POLARITY) PART NUMBER DEFINITION GUIDE Example Part Numbers: Part # Type Phase Polarity ACE403 Front EndSingle Positive ACE433 Front End Three Positive ACE403N Front EndSingle Negative ACE433N Front End Three Negative ACE403H Front EndSingle Positive ACE433H Front End Three Positive ACE403NH Front EndSingle Negative ACE433NH Front End Three Negative ACE 4 x 3 x x x xx - 1A Series 4=4kW x 3Bays 12kW Total Power 0 = 1Ø Rev. Blank=Non-Compliant Y0=5 of 6 Compliant Z0=6 of 6 Compliant RoHS Compliance 3 = 3Ø Input Phase 3 = 3 Slots Output V Blank = Bus Bar H = Positronic (front-end only) Backplane Connector Blank = Front End T = Rectifier Type Blank = Positive N = Negative Polarity Backplane Connector Bus Bar Bus Bar Bus Bar Bus Bar Positronic Positronic Positronic Positronic ACE 4 x 3 x x x xx - 1A rev 100506 Lineage Power 3000 Skyline Dr. Mesquite, TX 75149 Phone: (972) 284-2000 Series 4=4kW x 3Bays 12kW Total Power 0 = 1Ø Rev. Blank=Non-Compliant Lineage Power Y0=5 of 6 Compliant Z0=6 of 6 Compliant 2841 Dow Avenue RoHS Compliance 3 = 3Ø Tustin, CA 92780 USA Blank = Bus Bar Input Phase Phone: (714) 544-6665 H = Positronic (front-end only) 3 = 3 Slots Backplane Connector Output V Blank = Front End Blank = Positive www.lineagepower.com/oem Lineage Power (China) 1353 Chenqiao Road, Shanghai Sengpu Industrial Park Shanghai, 201401 China Phone: 021 6710 8910