CP3CN23 Reprogrammable Connectivity Processor with Dual CAN Interfaces 1.0 General Description The CP3CN23 connectivity processor combines high performance with the massive integration needed for embedded applications. A powerful RISC core with on-chip SRAM and Flash memory provides high computing bandwidth, hardware communications peripherals provide high-I/O bandwidth, and an external bus provides system expandability. On-chip communications peripherals include: dual CAN controllers, Microwire/Plus, SPI, ACCESS.bus, quad UART, 12-bit A/D converter, and Advanced Audio Interface (AAI). Additional on-chip peripherals include Random Number Generator (RNG), DMA controller, CVSD/PCM conversion module, Timing and Watchdog Unit, Versatile Timer Unit, Multi-Function Timer, and Multi-Input Wake-Up (MIWU) unit. trade-off between battery size and operating time for handheld and portable applications. In addition to providing the features needed for the next generation of embedded products, the CP3CN23 is backed up by the software resources designers need for rapid time-tomarket, including an operating system, peripheral drivers, reference designs, and an integrated development environment. National Semiconductor offers a complete and industryproven application development environment for CP3CN23 applications, including the IAR Embedded Workbench, iSYSTEM winIDEA and iC3000 Active Emulator, and Application Software. Hand-held devices can be both smaller and lower in cost for maximum consumer appeal. The low voltage and advanced power-saving modes achieve new design points in the Block Diagram Clock Generator 12 MHz and 32 kHz Oscillator CR16C CPU Core PLL and Clock Generator Power-on-Reset 256K Bytes Flash Program Memory 8K Bytes Flash Data Dual CAN 2.0B Controller 32K Bytes Static RAM Serial Debug Interface CPU Core Bus Bus Interface Unit DMA Controller Peripheral Bus Controller Interrupt Control Unit CVSD/PCM Converter Power Management Timing and Watchdog Unit Random Number Generator Peripheral Bus GPIO Audio Interface Microwiire/ SPI Quad UART ACCESS .bus Versatile Timer Unit Muti-Function Timer Multi-Input Wake-Up 8-Channel 12-bit ADC DS310 TRI-STATE is a registered trademark of National Semiconductor Corporation. ©2004 National Semiconductor Corporation www.national.com CP3CN23 Connectivity Processor with Bluetooth and Dual CAN Interfaces FINAL JULY 2004 CP3CN23 Table of Contents 1.0 2.0 3.0 General Description . . . . . . . . . . . . . . . . . . . . . . . . . . 1 Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Device Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 3.1 3.2 3.3 3.4 3.5 3.6 3.7 3.8 3.9 3.10 3.11 3.12 3.13 3.14 3.15 3.16 3.17 3.18 3.19 3.20 3.21 3.22 4.0 5.0 24 25 25 25 28 Module Configuration Register (MCFG) . . . . . . . . . . . . . . . . . . . . 29 Module Status Register (MSTAT). . . . . . . . . . . . . . . . . . . . . . . . . 30 Software Reset Register (SWRESET) . . . . . . . . . . . . . . . . . . . . . 30 22.0 Flash Memory Protection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Flash Memory Organization . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Flash Memory Operations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Information Block Words . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Flash Memory Interface Registers . . . . . . . . . . . . . . . . . . . . . . . . 23.0 Channel Assignment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Transfer Types . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Operation Modes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Software DMA Request . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Debug Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . DMA Controller Register Set . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24.0 Non-Maskable Interrupts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Maskable Interrupts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Interrupt Controller Registers . . . . . . . . . . . . . . . . . . . . . . . . . . . . Maskable Interrupt Sources . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Nested Interrupts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25.0 External Crystal Network . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Main Clock . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Slow Clock . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . PLL Clock . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . System Clock . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Auxiliary Clocks . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Power-On Reset . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . External Reset . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Clock and Reset Registers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26.0 27.0 28.0 Active Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Power Save Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Idle Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Halt Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . High-Frequency Oscillator and PLL Control . . . . . . . . . . . . . . . . . Power Management Registers . . . . . . . . . . . . . . . . . . . . . . . . . . . Switching Between Power Modes . . . . . . . . . . . . . . . . . . . . . . . . 29.0 14.0 Input/Output Ports. . . . . . . . . . . . . . . . . . . . . . . . . . . 67 15.0 12-Bit Analog to Digital Converter . . . . . . . . . . . . . . 71 14.1 14.2 15.1 15.2 15.3 15.4 15.5 30.0 31.0 Port Registers. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 67 Open-Drain Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 70 Functional Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Touchscreen Interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ADC Operation in Power-Saving Modes . . . . . . . . . . . . . . . . . . . Freeze . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ADC Register Set . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 71 73 75 75 75 Random Number Generator (RNG) . . . . . . . . . . . . . 80 16.1 16.2 Freeze . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 80 Random Number Generator Register Set . . . . . . . . . . . . . . . . . . 81 www.national.com 2 ACB Protocol Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ACB Functional Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . ACCESS.bus Interface Registers . . . . . . . . . . . . . . . . . . . . . . . . Usage Hints . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 154 156 158 162 TWM Structure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Timer T0 Operation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Watchdog Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . TWM Registers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Watchdog Programming Procedure . . . . . . . . . . . . . . . . . . . . . . 165 165 166 166 168 Timer Structure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Timer Operating Modes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Timer Interrupts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Timer I/O Functions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Timer Registers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 169 170 175 175 176 VTU Functional Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . 179 VTU Registers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 183 Absolute Maximum Ratings . . . . . . . . . . . . . . . . . . . . . . . . . . . . DC Electrical Characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . ADC Electrical Characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . Flash Memory On-Chip Programming . . . . . . . . . . . . . . . . . . . . Output Signal Levels. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Clock and Reset Timing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . UART Timing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . I/O Port Timing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Advanced Audio Interface (AAI) Timing . . . . . . . . . . . . . . . . . . . Microwire/SPI Timing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ACCESS.bus Timing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Multi-Function Timer (MFT) Timing . . . . . . . . . . . . . . . . . . . . . . Versatile Timing Unit (VTU) Timing . . . . . . . . . . . . . . . . . . . . . . External Bus Timing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 212 212 213 214 215 215 217 218 219 221 226 229 230 231 Pin Assignments . . . . . . . . . . . . . . . . . . . . . . . . . . . 237 29.1 29.2 Multi-Input Wake-Up Registers. . . . . . . . . . . . . . . . . . . . . . . . . . . 62 Programming Procedures. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 66 148 150 151 151 152 Register Map. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 187 Register Bit Fields . . . . . . . . . . . . . . . . . . . . . . . . . . 202 Electrical Characteristics . . . . . . . . . . . . . . . . . . . . 212 28.1 28.2 28.3 28.4 28.5 28.6 28.7 28.8 28.9 28.10 28.11 28.12 28.13 28.14 56 56 57 57 57 57 59 Microwire Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Master Mode. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Slave Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Interrupt Generation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Microwire Interface Registers . . . . . . . . . . . . . . . . . . . . . . . . . . . Versatile Timer Unit (VTU) . . . . . . . . . . . . . . . . . . . . 179 25.1 25.2 52 53 53 53 54 54 54 54 54 136 136 141 145 Multi-Function Timer . . . . . . . . . . . . . . . . . . . . . . . . 169 24.1 24.2 24.3 24.4 24.5 47 47 47 50 50 Functional Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . UART Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . UART Registers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Baud Rate Calculations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Timing and Watchdog Module . . . . . . . . . . . . . . . . 165 23.1 23.2 23.3 23.4 23.5 41 41 42 43 43 43 131 131 132 132 132 132 132 133 133 ACCESS.bus Interface . . . . . . . . . . . . . . . . . . . . . . . 154 22.1 22.2 22.3 22.4 31 31 32 34 35 Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . PCM Conversions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . CVSD Conversion. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . PCM to CVSD Conversion . . . . . . . . . . . . . . . . . . . . . . . . . . . . . CVSD to PCM Conversion . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Interrupt Generation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . DMA Support . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Freeze. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . CVSD/PCM Converter Registers . . . . . . . . . . . . . . . . . . . . . . . . Microwire/SPI Interface . . . . . . . . . . . . . . . . . . . . . . 148 21.1 21.2 21.3 21.4 21.5 Multi-Input Wake-Up . . . . . . . . . . . . . . . . . . . . . . . . . 61 13.1 13.2 16.0 21.0 Power Management . . . . . . . . . . . . . . . . . . . . . . . . . . 56 12.1 12.2 12.3 12.4 12.5 12.6 12.7 13.0 Operating Environment. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Bus Interface Unit (BIU) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Bus Cycles . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . BIU Control Registers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Wait and Hold States . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 116 116 119 119 119 121 124 UART Modules . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 136 20.1 20.2 20.3 20.4 Triple Clock and Reset . . . . . . . . . . . . . . . . . . . . . . . 51 11.1 11.2 11.3 11.4 11.5 11.6 11.7 11.8 11.9 12.0 20.0 Interrupts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 47 10.1 10.2 10.3 10.4 10.5 11.0 15 15 16 17 18 19 19 Audio Interface Signals . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Audio Interface Modes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Bit Clock Generation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Frame Clock Generation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Audio Interface Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Communication Options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Audio Interface Registers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . CVSD/PCM Conversion Module . . . . . . . . . . . . . . . 131 19.1 19.2 19.3 19.4 19.5 19.6 19.7 19.8 19.9 DMA Controller . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41 9.1 9.2 9.3 9.4 9.5 9.6 10.0 19.0 Functional Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 82 Basic CAN Concepts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 83 Message Transfer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 91 Acceptance Filtering . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 92 Receive Structure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 93 Transmit Structure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 96 Interrupts. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 98 Time Stamp Counter. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 99 Memory Organization . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 100 CAN Controller Registers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 101 System Start-Up and Multi-Input Wake-Up. . . . . . . . . . . . . . . . . 113 Usage Hint . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 115 Advanced Audio Interface . . . . . . . . . . . . . . . . . . . . 116 18.1 18.2 18.3 18.4 18.5 18.6 18.7 Flash Memory . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31 8.1 8.2 8.3 8.4 8.5 9.0 18.0 System Configuration Registers . . . . . . . . . . . . . . . 29 7.1 7.2 7.3 8.0 4 4 4 4 4 4 5 5 5 5 5 5 6 6 6 6 6 6 6 7 7 7 Memory. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24 6.1 6.2 6.3 6.4 6.5 7.0 General-Purpose Registers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Dedicated Address Registers . . . . . . . . . . . . . . . . . . . . . . . . . . . . Processor Status Register (PSR) . . . . . . . . . . . . . . . . . . . . . . . . . Configuration Register (CFG). . . . . . . . . . . . . . . . . . . . . . . . . . . . Addressing Modes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Stacks. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Instruction Set. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . CAN Module . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 82 17.1 17.2 17.3 17.4 17.5 17.6 17.7 17.8 17.9 17.10 17.11 17.12 Signal Descriptions . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 CPU Architecture. . . . . . . . . . . . . . . . . . . . . . . . . . . . 15 5.1 5.2 5.3 5.4 5.5 5.6 5.7 6.0 CR16C CPU Core . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Memory. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Input/Output Ports . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Bus Interface Unit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Interrupt Control Unit (ICU). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Multi-Input Wake-up . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . CAN Interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Quad UART . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Advanced Audio interface. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . CVSD/PCM Conversion Module. . . . . . . . . . . . . . . . . . . . . . . . . . . 12-bit Analog to Digital Converter. . . . . . . . . . . . . . . . . . . . . . . . . . Random Number Generator . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Microwire/SPI . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ACCESS.bus Interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Multi-Function Timer. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Timing and Watchdog Module . . . . . . . . . . . . . . . . . . . . . . . . . . . . Versatile Timer Unit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Triple Clock and Reset . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Power Management . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . DMA Controller . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Serial Debug Interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Development Support. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17.0 LQFP-128 Package . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 237 LQFP-144 Package . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 240 Revision History . . . . . . . . . . . . . . . . . . . . . . . . . . . . 244 Physical Dimensions . . . . . . . . . . . . . . . . . . . . . . . . 245 Features Extensive Power and Clock Management Support On-chip Phase Locked Loop Support for multiple clock options Fully static RISC processor core, capable of operating Dual clock and reset from 0 to 24 MHz with zero wait/hold states Power-down modes Minimum 41.7 ns instruction cycle time with a 24-MHz internal clock frequency, based on a 12-MHz external input Flexible I/O 47 independently vectored peripheral interrupts Up to 56 general-purpose I/O pins (shared with on-chip peripheral I/O) On-Chip Memory Programmable I/O pin characteristics: TRI-STATE out 256K bytes reprogrammable Flash program memory put, push-pull output, weak pull-up input, high-imped 8K bytes Flash data memory ance input 32K bytes of static RAM data memory Schmitt triggers on general-purpose inputs Addresses up to 12M bytes of external memory Multi-Input Wake-Up (MIWU) capability Broad Range of Hardware Communications Peripherals Power Supply CPU Features ACCESS.bus serial bus (compatible with Philips I2C bus) Dual CAN interface with 15 message buffers conforming to CAN specification 2.0B active 8/16-bit SPI, Microwire/Plus serial interface Four-channel Universal Asynchronous Receiver/Transmitter (UART), one channel has USART capability Advanced Audio Interface (AAI) to connect to external 8/ 13-bit PCM Codecs as well as to ISDN-Controllers through the IOM-2 interface (slave only) CVSD/PCM converter supporting one bidirectional audio connection I/O port operation at 2.5V to 3.3V Core logic operation at 2.5V On-chip power-on reset Temperature Range -40°C to +85°C (Industrial) Packages LQFP-128, LQFP-144 Complete Development Environment Pre-integrated hardware and software support for rapid prototyping and production Integrated environment Project manager Multi-file C source editor High-level C source debugger Comprehensive, integrated, one-stop technical support General-Purpose Hardware Peripherals 12-bit A/D Converter (ADC) Dual 16-bit Multi-Function Timer (MFT) Versatile Timer Unit with four subsystems (VTU) Four-channel DMA controller Timing and Watchdog Unit Random Number Generator peripheral CP3CN23 Connectivity Processor Selection Guide NSID Speed Temp. Range (MHz) Program Flash (Kbytes) Data Flash (Kbytes) SRAM (Kbytes) External Address Lines I/Os Package Type CP3CN23G18NEP 24 -40° to +85°C 256 8 32 0 56 LQFP-128 CP3CN23G18NEPNOPB 24 -40° to +85°C 256 8 32 0 56 LQFP-128 CP3CN23G18NEPX 24 -40° to +85°C 256 8 32 0 56 LQFP-128 CP3CN23G18NEPXNOPB 24 -40° to +85°C 256 8 32 0 56 LQFP-128 CP3CN23Y98NEP 24 -40° to +85°C 256 8 32 23 50 LQFP-144 CP3CN23Y98NEPNOPB 24 -40° to +85°C 256 8 32 23 50 LQFP-144 CP3CN23Y98NEPX 24 -40° to +85°C 256 8 32 23 50 LQFP-144 CP3CN23Y98NEPXNOPB 24 -40° to +85°C 256 8 32 23 50 LQFP-144 NEP - Erased part (serial number in Information Block 1); X - Tape and reel; NOPB - No lead solder 3 www.national.com CP3CN23 2.0 CP3CN23 3.0 Device Overview The CP3CN23 connectivity processor is a complete microcomputer with all system timing, interrupt logic, program memory, data memory, and I/O ports included on-chip, making it well-suited to a wide range of embedded applications. The block diagram on page 1 shows the major on-chip components of the CP3CN23 devices. 3.1 3.3 The device has up to 50 software-configurable I/O pins, organized into seven ports called Port B, Port C, Port E, Port G, Port H, Port I, and Port J. Each pin can be configured to operate as a general-purpose input or general-purpose output. In addition, many I/O pins can be configured to operate as inputs or outputs for on-chip peripheral modules such as the UART, timers, or Microwire/SPI interface. CR16C CPU CORE The CP3CN23 device implements the CR16C CPU core module. The high performance of the CPU core results from the implementation of a pipelined architecture with a twobytes-per-cycle pipelined system bus. As a result, the CPU can support a peak execution rate of one instruction per clock cycle. The I/O pin characteristics are fully programmable. Each pin can be configured to operate as a TRI-STATE output, pushpull output, weak pull-up input, or high-impedance input. 3.4 MEMORY The BIU uses a set of control registers to determine how many wait states and hold states are used when accessing Flash program memory and the I/O area. At start-up, the configuration registers are set for slowest possible memory access. To achieve fastest possible program execution, appropriate values must be programmed. These settings vary with the clock frequency and the type of off-chip device being accessed. The CP3CN23 devices support a uniform linear address space of up to 16 megabytes. Three types of on-chip memory occupy specific regions within this address space, along with any external memory: BUS INTERFACE UNIT The Bus Interface Unit (BIU) controls access to internal/external memory and I/O. It determines the configured parameters for bus access (such as the number of wait states for memory access) and issues the appropriate bus signals for each requested access. For more information, please refer to the CR16C Programmer’s Reference Manual (document number 424521772101, which may be downloaded from National’s web site at http://www.national.com). 3.2 INPUT/OUTPUT PORTS 256K bytes of Flash program memory 8K bytes of Flash data memory 32K bytes of static RAM Up to 12M bytes of external memory (144-pin devices) 3.5 The 256K bytes of Flash program memory are used to store the application program and real-time operating system. The Flash memory has security features to prevent unintentional programming and to prevent unauthorized access to the program code. This memory can be programmed with an external programming unit or with the device installed in the application system (in-system programming). INTERRUPT CONTROL UNIT (ICU) The ICU receives interrupt requests from internal and external sources and generates interrupts to the CPU. An interrupt is an event that temporarily stops the normal flow of program execution and causes a separate interrupt handler to be executed. After the interrupt is serviced, CPU execution continues with the next instruction in the program following the point of interruption. The 8K bytes of Flash data memory are used for non-vola- Interrupts from the timers, UARTs, Microwire/SPI interface, tile storage of data entered by the end-user, such as config- and Multi-Input Wake-Up, are all maskable interrupts; they uration settings. can be enabled or disabled by software. There are 47 The 32K bytes of static RAM are used for temporary storage maskable interrupts, assigned to 47 linear priority levels. of data and for the program stack and interrupt stack. Read and write operations can be byte-wide or word-wide, depending on the instruction executed by the CPU. The highest-priority interrupt is the Non-Maskable Interrupt (NMI), which is generated by a signal received on the NMI input pin. Up to 12M bytes of external memory can be added on an 3.6 MULTI-INPUT WAKE-UP external bus. The external bus is only available on devices The two Multi-Input Wake-Up (MIWU) modules can be used in 144-pin packages. for two purposes: to provide inputs for waking up (exiting) For Flash program and data memory, the device internally from the Halt, Idle, or Power Save mode, and to provide gengenerates the necessary voltages for programming. No ad- eral-purpose edge-triggered maskable interrupts to the levditional power supply is required. el-sensitive interrupt control unit (ICU) inputs. Each 16channel module generates four programmable interrupts to the ICU, for a total of 8 ICU inputs generated from 32 MIWU inputs. Channels can be individually enabled or disabled, and programmed to respond to positive or negative edges. www.national.com 4 CAN INTERFACE 3.11 Two CAN modules provide Full CAN 2.0B class, CAN serial bus interface for applications that require a high-speed (up to 1 Mbits per second) or a low-speed interface with CAN bus master capability. The data transfer between CAN and the CPU is established by 15 memory-mapped message buffers, which can be individually configured as receive or transmit buffers. An incoming message is filtered by two masks, one for the first 14 message buffers and another one for the 15th message buffer to provide a basic CAN path. A priority decoder allows any buffer to have the highest or lowest transmit priority. Remote transmission requests can be processed automatically by automatic reconfiguration to a receiver after transmission or by automated transmit scheduling upon reception. In addition, a time stamp counter (16bits wide) is provided to support real-time applications. This device contains an 8-channel, multiplexed input, successive approximation, 12-bit Analog-to-Digital Converter. It supports both Single Ended and Differential modes of operation. The integrated 12-bit ADC provides the following features: The CAN modules are fast core bus peripherals, which allow single-cycle byte or word read/write access. A set of diagnostic features (such as loopback, listen only, and error identification) support the development with the CAN module and provide a sophisticated error management tool. 8-channel, multiplexed input 4 differential channels Single-ended and differential external filtering capability 12-bit resolution; 11-bit accuracy 15-microsecond conversion time Support for 4-wire touchscreen applications External start trigger Programmable start delay after start trigger Poll or interrupt on done The ADC is compatible with 4-wire resistive touchscreen applications and is intended to provide the resolution necessary to support handwriting recognition. Low-ohmic touchscreen drivers are provided internally on the ADC[3:0] pins. Pendown detection is also provided. The CAN receivers can trigger a wake-up condition out of the low-power modes through the Multi-Input Wake-Up module. 3.8 12-BIT ANALOG TO DIGITAL CONVERTER The ADC provides several options for the voltage reference source. The positive reference can be ADVCC (internal), VREFP, ADC0, or ADC3. The negative reference can be ADVCC (internal), ADC1, or ADC2. QUAD UART Four UART modules support a wide range of programmable Two specific analog channel selection modes are supportbaud rates and data formats, parity generation, and several ed. These are as follows: error detection schemes. The baud rate is generated on Allow any specific channel to be selected at one time. chip, under software control. One UART channel supports The A/D Converter performs the specific conversion rehardware flow control, DMA, and USART capability (synquested and stops. chronous mode). Allow any differential channel pair to be selected at one The UARTs offer a wake-up condition from the low-power time. The A/D Converter performs the specific differential modes using the Multi-Input Wake-Up module. conversion requested and stops. 3.9 ADVANCED AUDIO INTERFACE In both Single-Ended and Differential modes, there is the capability to connect the analog multiplexer output and A/D converter input to external pins. This provides the ability to externally connect a common filter/signal conditioning circuit for the A/D Converter. The audio interface provides a serial synchronous, full-duplex interface to CODECs and similar serial devices. Transmit and receive paths operate asynchronously with respect to each other. Each path uses three signals for communication: shift clock, frame synchronization, and data. 3.12 RANDOM NUMBER GENERATOR When the receiver and transmitter use separate shift clocks RNG peripheral for use in Trusted Computer Peripheral Apand frame sync signals, the interface operates in its asyn- plications (TCPA) to improve the authenticity, integrity, and chronous mode. Alternatively, the transmit and receive path privacy of Internet-based communication and commerce. can share the same shift clock and frame sync signals for synchronous mode operation. 3.10 CVSD/PCM CONVERSION MODULE The CVSD/PCM module performs conversion between CVSD data and PCM data, in which the CVSD encoding is as defined in the Bluetooth specification and the PCM data can be 8-bit µ-Law, 8-bit A-Law, or 13-bit to 16-bit Linear. 5 www.national.com CP3CN23 3.7 CP3CN23 3.13 MICROWIRE/SPI 3.17 VERSATILE TIMER UNIT The Microwire/SPI (MWSPI) interface module supports synchronous serial communications with other devices that conform to Microwire or Serial Peripheral Interface (SPI) specifications. It supports 8-bit and 16-bit data transfers. The Versatile Timer Unit (VTU) module contains four independent timer subsystems, each operating in either dual 8bit PWM configuration, as a single 16-bit PWM timer, or a 16-bit counter with two input capture channels. Each of the The Microwire interface allows several devices to communi- four timer subsystems offer an 8-bit clock prescaler to accate over a single system consisting of four wires: serial in, commodate a wide range of frequencies. serial out, shift clock, and slave enable. At any given time, 3.18 TRIPLE CLOCK AND RESET the Microwire interface operates as the master or a slave. The Microwire interface supports the full set of slave select The Triple Clock and Reset module generates a high-speed main System Clock from an external crystal network. It also for multi-slave implementation. provides the main system reset signal and a power-on reset In master mode, the shift clock is generated on-chip under function. software control. In slave mode, a wake-up out of a lowpower mode may be triggered using the Multi-Input Wake- This module generates a slow System Clock (32.768 kHz) from an optional external crystal network. The Slow Clock is Up module. used for operating the device in a low-power mode. The 3.14 ACCESS.BUS INTERFACE 32.768 kHz external crystal network is optional, because The ACCESS.bus interface module (ACB) is a two-wire se- the low speed System Clock can be derived from the highrial interface compatible with the ACCESS.bus physical lay- speed clock by a prescaler. Also, two independent clocks dier. It is also compatible with Intel’s System Management vided down from the high speed clock are available on outBus (SMBus) and Philips’ I2C bus. The ACB module can be put pins. configured as a bus master or slave, and it can maintain bi- The Triple Clock and Reset module provides the clock sigdirectional communications with both multiple master and nals required for the operation of the various CP3CN23 onslave devices. chip modules. From external crystal networks, it generates The ACCESS.bus receiver can trigger a wake-up condition the Main Clock, which can be scaled up to 24 MHz from an out of the low-power modes through the Multi-Input Wake- external 12 MHz input clock, and a 32.768 kHz secondary System Clock. The 12 MHz external clock is primarily used Up module. as the reference frequency for the on-chip PLL. The clock 3.15 MULTI-FUNCTION TIMER for modules which require a fixed clock rate (e.g. the CVSD/ The Multi-Function Timer (MFT) module contains a pair of PCM transcoder) is also generated through prescalers from 16-bit timer/counter registers. Each timer/counter unit can the 12 MHz clock. The PLL may be used to drive the highspeed System Clock through a prescaler. Alternatively, the be configured to operate in any of the following modes: high speed System Clock can be derived directly from the — Processor-Independent Pulse Width Modulation 12 MHz Main Clock. (PWM) mode: Generates pulses of a specified width and duty cycle and provides a general-purpose timer/ In addition, this module generates the device reset by using reset input signals coming from an external reset and varicounter. — Dual Input Capture mode: Measures the elapsed time ous on-chip modules. between occurrences of external event and provides 3.19 POWER MANAGEMENT a general-purpose timer/counter. — Dual Independent Timer mode: Generates system The Power Management Module (PMM) improves the effitiming signals or counts occurrences of external ciency of the device by changing the operating mode and power consumption to match the required level of activity. events. The device can operate in any of four power modes: — Single Input Capture and Single Timer mode: Provides one external event counter and one system timer. 3.16 — Active: The device operates at full speed using the high-frequency clock. All device functions are fully operational. — Power Save: The device operates at reduced speed using the Slow Clock. The CPU and some modules can continue to operate at this low speed. — Idle: The device is inactive except for the Power Management Module and Timing and Watchdog Module, which continue to operate using the Slow Clock. — Halt: The device is inactive but still retains its internal state (RAM and register contents). TIMING AND WATCHDOG MODULE The Timing and Watchdog Module (TWM) contains a RealTime timer and a Watchdog unit. The Real-Time Clock Timing function can be used to generate periodic real-time based system interrupts. The timer output is one of 16 inputs to the Multi-Input Wake-Up module which can be used to exit from a power-saving mode. The Watchdog unit is designed to detect the application program getting stuck in an infinite loop resulting in loss of program control or “runaway” programs. When the watchdog triggers, it resets the device. The TWM is clocked by the low-speed System Clock. www.national.com 6 DMA CONTROLLER 3.21 The Direct Memory Access Controller (DMAC) can speed up data transfer between memory and I/O devices or between two memories, relative to data transfers performed directly by the CPU. A method called cycle-stealing allows the CPU and the DMAC to share the CPU bus efficiently. The DMAC implements four independent DMA channels. DMA requests from a primary and a secondary source are recognized for each DMA channel, as well as a software DMA request issued directly by the CPU. Table 1 shows the DMA channel assignment on the CP3CN23 architecture. The following on-chip modules can assert a DMA request to the DMAC: • • • • The Serial Debug Interface module (SDI module) provides a JTAG-based serial link to an external debugger, for example running on a PC. In addition, the SDI module integrates an on-chip debug module, which allows the user to set up to eight hardware breakpoints on instruction execution and data transfer. The SDI module can act as a CPU bus master to access all memory mapped resources, such as RAM and peripherals. Therefore it also allows for fast program code download into the on-chip Flash program memory using the JTAG interface. 3.22 Table 1 shows how the four DMA channels are assigned to the modules listed above. Channel National Semiconductor offers a complete and industryproven application development environment for CP3CN23 applications, including the IAR Embedded Workbench, iSYSTEM winIDEA and iC3000 Active Emulator, and Application Software. See your National Semiconductor sales representative for current information on availability and features of emulation equipment and evaluation boards. DMA Channel Assignment Primary/ Secondary Peripheral Transaction Primary Reserved Read/Write Secondary UART0 Read Primary UART0 Write Secondary Unused N/A Primary AAI Read Secondary CVSD/PCM Read Primary AAI Write Secondary CVSD/PCM Write DEVELOPMENT SUPPORT In addition to providing the features needed for the next generation of embedded products, the CP3CN23 devices are backed up by the software resources designers need for rapid product development, including an operating system, peripheral drivers, reference designs, and an integrated development environment. CR16C (Software DMA request) USART Advanced Audio Interface CVSD/PCM Converter Table 1 SERIAL DEBUG INTERFACE 0 1 2 3 The interface can handle data words of either 8- or 16-bit length and data frames can consist of up to four slots. In the normal mode of operation, the interface only transfers one word at a periodic rate. In the network mode, the interface transfers multiple words at a periodic rate. The periodic rate is also called a data frame and each word within one frame is called a slot. The beginning of each new data frame is marked by the frame sync signal. 7 www.national.com CP3CN23 3.20 CP3CN23 4.0 Signal Descriptions X1CKI/BBCLK X1CKO 12 MHz Crystal or Ext. Clock 8 8 1 1 1 1 6 6 15 14 Chip Reset JTAG I/F to Debugger/ Programmer Mode Selection MFT ADC/ Touchscreen ACCESS.bus CAN0 bus CAN1 bus AVCC AGND ADVCC ADGND VCC GND IOVCC X1CKI/BBCLK X1CKO 12 MHz Crystal GPIO or Ext. Clock X2CKI X2CKO 32.768 kHz Crystal Power Supply PB[7:0] PC[7:0] X2CKI X2CKO 32.768 kHz Crystal 1 1 1 CP3CN23 (LQFP-128) IOGND RESET TMS TDI TDO TCK RDY ENV0 ENV1 ENV2 PG7/TA Power Supply 6 6 PH7/CAN0TX PE6/CAN1RX PE7/CAN1TX 10 PGO PG1 PG3 PG4 PG5 PE0/RXD0 PE1/TXD0 PE2/RTS PE3/CTS PE4/CKX/TB PH0/RXD1/WUI11 PH1/TXD1/WUI12 PH2/RXD1/WUI13 ADC0/TSX+ PH3/TXD1/WUI14 ADC1/TSY+ PH4/RXD1/WUI15 ADC2/TSXPH5/TXD1/WUI16 ADC3/TSYADC4/MUXOUT0 ADC5/MUXOUT1 PF0/MSK/TIO1 ADC6 PF1/MDIDO/TIO2 ADC7/ADCIN PF2/MDODO/TIO3 PJ7/ASYNC/ PF3/MWCS/TIO4 WUI9 VREFP PF4/SCK/TIO5 PF5/SFS/TIO6 PF6/STD/TIO7 SDA PF7/SRD/TIO8 SCL PE5/SRFS/NMI PH6/CAN0RX/ WUI17 1 PG2/SRCLK 11 GPIO Chip Reset JTAG I/F to Debugger/ Programmer GND IOVCC CP3CN23 (LQFP-144) IOGND PGO PG1 RESET PG3 PG4 PG5 TMS TDI TDO UART0 TCK RDY UART0/MFT Mode Selection ENV0 ENV1 ENV2 UART1/MIWU MFT UART2/MIWU UART3/MIWU ADC/ Touchscreen Microwire/ SPI/ VTU AAI/ VTU ACCESS.bus PE0/RXD0 PE1/TXD0 PE2/RTS PE3/CTS PE4/CKX/TB PH0/RXD1/WUI11 PH1/TXD1/WUI12 PH2/RXD1/WUI13 ADC0/TSX+ PH3/TXD1/WUI14 ADC1/TSY+ PH4/RXD1/WUI15 ADC2/TSXPH5/TXD1/WUI16 ADC3/TSYADC4/MUXOUT0 ADC5/MUXOUT1 PF0/MSK/TIO1 ADC6 PF1/MDIDO/TIO2 ADC7/ADCIN PF2/MDODO/TIO3 PJ7/ASYNC/ PF3/MWCS/TIO4 WUI9 VREFP PF4/SCK/TIO5 PF5/SFS/TIO6 PF6/STD/TIO7 SDA PF7/SRD/TIO8 SCL PE5/SRFS/NMI AAI CAN1 bus MIWU 8 8 23 External Bus Interface GPIO UART0 UART0/MFT UART1/MIWU PG7/TA AAI/NMI CAN0 bus PJ0/WUI18 PJ1/WUI19 PJ2/WUI20 PJ3/WUI21 PJ4/WUI22 PJ5/WUI23 PJ6/WUI24 PG6/WUI10 AVCC AGND ADVCC ADGND VCC PB[7:0] PC[7:0] A[22:0] SEL0 SEL1 SEL2 SELIO WR0 WR1 RD PH6/CAN0RX/ WUI17 PH7/CAN0TX PE6/CAN1RX PE7/CAN1TX PG2/SRCLK PJ0/WUI18 PG6/WUI10 UART2/MIWU UART3/MIWU Microwire/ SPI/ VTU AAI/ VTU AAI/NMI AAI MIWU DS307 Figure 1. CP3CN23 Device SIgnals Some pins may be enabled as general-purpose I/O-port pins or as alternate functions associated with specific peripherals or interfaces. These pins may be individually configured as port pins, even when the associated peripheral or interface is enabled. Table 2 describes the device signals for the LQFP-128 package. Table 3 describes the device signals for the LQFP-144 package. www.national.com 8 I/O Alternate Name Name Pins Primary Function X1CKI 1 Input 12 MHz Oscillator Input BBCLK BB reference clock for the RF Interface X1CKO 1 Output 12 MHz Oscillator Output None None X2CKI 1 Input 32 kHz Oscillator Input None None X2CKO 1 Output 32 kHz Oscillator Output None None RESET 1 Input Chip general reset None None ENV0 1 I/O Special mode select input with internal pull-up during reset PLLCLK PLL Clock Output ENV1 1 I/O Special mode select input with internal pull-up during reset CPUCLK CPU Clock Output ENV2 1 I/O Special mode select input with internal pull-up during reset SLOWCLK Slow Clock Output TMS 1 Input JTAG Test Mode Select (with internal weak pull-up) None None TCK 1 Input JTAG Test Clock Input (with internal weak pull-up) None None TDI 1 Input JTAG Test Data Input (with internal weak pull-up) None None TDO 1 Output JTAG Test Data Output None None RDY 1 Output NEXUS Ready Output None None VCC 6 Input 2.5V Core Logic Power Supply None None GND 6 Input Core Ground None None IOVCC 16 Input 2.5–3.3V I/O Power Supply None None IOGND 15 Input I/O Ground None None AVCC 1 Input PLL Analog Power Supply None None AGND 1 Input PLL Analog Ground None None ADVCC 1 Input ADC Analog Power Supply None None ADGND 1 Input ADC Analog Ground None None SCL 1 I/O ACCESS.bus Clock None None SDA 1 I/O ACCESS.bus Serial Data None None ADC0 1 I/O ADC Input Channel 0 TSX+ Touchscreen X+ contact ADC1 1 I/O ADC Input Channel 1 TSY+ Touchscreen Y+ contact ADC2 1 I/O ADC Input Channel 2 TSX- Touchscreen X- contact ADC3 1 I/O ADC Input Channel 3 TSY- Touchscreen Y- contact ADC4 1 I/O ADC Input Channel 4 MUXOUT0 Analog Multiplexer Output 0 ADC5 1 I/O ADC Input Channel 5 MUXOUT1 Analog Multiplexer Output 1 ADC6 1 Input ADC Input Channel 6 None None ADC7 1 Input ADC Input Channel 7 ADCIN ADC Input (in MUX mode) 9 Alternate Function www.national.com CP3CN23 Table 2 CP3CN23 LQFP-128 Signal Descriptions CP3CN23 VREFP 1 Input ADC Positive Voltage Reference None None PB[7:0] 8 I/O Generic I/O None None PC[7:0] 8 I/O Generic I/O None None PE0 1 I/O Generic I/O RXD0 UART Channel 0 Receive Data Input PE1 1 I/O Generic I/O TXD0 UART Channel 0 Transmit Data Output PE2 1 I/O Generic I/O RTS UART Channel 0 Ready-To-Send Output PE3 1 I/O Generic I/O CTS UART Channel 0 Clear-To-Send Input CKX UART Channel 0 Clock Input PE4 1 I/O Generic I/O TB Multi Function Timer Port B SRFS AAI Receive Frame Sync PE5 1 NMI Non-Maskable Interrupt Input PE6 1 I/O Generic I/O CAN1RX UART Channel 0 Ready-To-Send Output PE7 1 I/O Generic I/O CAN1TX UART Channel 0 Clear-To-Send Input MSK SPI Shift Clock PF0 1 I/O Generic I/O TIO1 Versatile Timer Channel 1 MDIDO SPI Master In Slave Out PF1 1 TIO2 Versatile Timer Channel 2 MDODI SPI Master Out Slave In PF2 1 TIO3 Versatile Timer Channel 3 MWCS SPI Slave Select Input PF3 1 TIO4 Versatile Timer Channel 4 SCK AAI Clock PF4 1 TIO5 Versatile Timer Channel 5 SFS AAI Frame Synchronization PF5 1 TIO6 Versatile Timer Channel 6 STD AAI Transmit Data Output PF6 1 TIO7 Versatile Timer Channel 7 SRD AAI Receive Data Input PF7 1 TIO8 Versatile Timer Channel 8 PG0 1 I/O Generic I/O None None PG1 1 I/O Generic I/O None None PG2 1 I/O Generic I/O SRCLK AAI Receive Clock PG3 1 I/O Generic I/O None None PG4 1 I/O Generic I/O None None PG5 1 I/O Generic I/O None None PG6 1 I/O Generic I/O WUI10 Multi-Input Wake-Up Channel 10 PG7 1 I/O Generic I/O TA Multi Function Timer Port A I/O I/O I/O I/O I/O I/O I/O I/O Primary Function Alternate Function Pins www.national.com I/O Alternate Name Name Generic I/O Generic I/O Generic I/O Generic I/O Generic I/O Generic I/O Generic I/O Generic I/O 10 Pins I/O PH0 1 PH1 1 PH2 1 PH3 1 PH4 1 PH5 1 PH6 1 PH7 1 I/O PJ0 1 PJ1 Alternate Name Primary Function Alternate Function RXD1 UART Channel 1 Receive Data Input WUI11 Multi-Input Wake-Up Channel 11 TXD1 UART Channel 1 Transmit Data Output WUI12 Multi-Input Wake-Up Channel 12 RXD2 UART Channel 2 Receive Data Input WUI13 Multi-Input Wake-Up Channel 13 TXD2 UART Channel 2 Transmit Data Output WUI14 Multi-Input Wake-Up Channel 14 RXD3 UART Channel 3 Receive Data Input WUI15 Multi-Input Wake-Up Channel 15 TXD3 UART Channel 3 Transmit Data Output WUI16 Multi-Input Wake-Up Channel 16 CAN0RX CAN Receive Input WUI17 Multi-Input Wake-Up Channel 17 Generic I/O CAN0TX CAN Transmit Output I/O Generic I/O WUI18 Multi-Input Wake-Up Channel 18 1 I/O Generic I/O WUI19 Multi-Input Wake-Up Channel 19 PJ2 1 I/O Generic I/O WUI20 Multi-Input Wake-Up Channel 20 PJ3 1 I/O Generic I/O WUI21 Multi-Input Wake-Up Channel 21 PJ4 1 I/O Generic I/O WUI22 Multi-Input Wake-Up Channel 22 PJ5 1 I/O Generic I/O WUI23 Multi-Input Wake-Up Channel 23 PJ6 1 I/O Generic I/O WUI24 Multi-Input Wake-Up Channel 24 ASYNC Start convert signal to ADC PJ7 1 I/O Generic I/O WUI9 Multi-Input Wake-Up Channel 9 I/O I/O I/O I/O I/O I/O I/O Generic I/O Generic I/O Generic I/O Generic I/O Generic I/O Generic I/O Generic I/O 11 www.national.com CP3CN23 Name CP3CN23 Table 3 CP3CN23 LQFP-144 Signal Descriptions Pins X1CKI 1 Input 12 MHz Oscillator Input BBCLK BB reference clock for the RF Interface X1CKO 1 Output 12 MHz Oscillator Output None None X2CKI 1 Input 32 kHz Oscillator Input None None X2CKO 1 Output 32 kHz Oscillator Output None None RESET 1 Input Chip general reset None None ENV0 1 I/O Special mode select input with internal pull-up during reset PLLCLK PLL Clock Output ENV1 1 I/O Special mode select input with internal pull-up during reset CPUCLK CPU Clock Output ENV2 1 I/O Special mode select input with internal pull-up during reset SLOWCLK Slow Clock Output TMS 1 Input JTAG Test Mode Select (with internal weak pull-up) None None TCK 1 Input JTAG Test Clock Input (with internal weak pull-up) None None TDI 1 Input JTAG Test Data Input (with internal weak pull-up) None None TDO 1 Output JTAG Test Data Output None None RDY 1 Output NEXUS Ready Output None None VCC 6 Input 2.5V Core Logic Power Supply None None GND 6 Input Core Ground None None IOVCC 10 Input 2.5–3.3V I/O Power Supply None None IOGND 11 Input I/O Ground None None AVCC 1 Input PLL Analog Power Supply None None AGND 1 Input PLL Analog Ground None None ADVCC 1 Input ADC Analog Power Supply None None ADGND 1 Input ADC Analog Ground None None SCL 1 I/O ACCESS.bus Clock None None SDA 1 I/O ACCESS.bus Serial Data None None ADC0 1 I/O ADC Input Channel 0 TSX+ Touchscreen X+ contact ADC1 1 I/O ADC Input Channel 1 TSY+ Touchscreen Y+ contact ADC2 1 I/O ADC Input Channel 2 TSX- Touchscreen X- contact ADC3 1 I/O ADC Input Channel 3 TSY- Touchscreen Y- contact ADC4 1 I/O ADC Input Channel 4 MUXOUT0 Analog Multiplexer Output 0 ADC5 1 I/O ADC Input Channel 5 MUXOUT1 Analog Multiplexer Output 1 ADC6 1 Input ADC Input Channel 6 None None ADC7 1 Input ADC Input Channel 7 ADCIN ADC Input (in MUX mode) www.national.com I/O Alternate Name Name Primary Function 12 Alternate Function VREFP 1 Input ADC Positive Voltage Reference None None PB[7:0] 8 I/O Generic I/O D[7:0] External Data Bus Bits 0 to 7 PC[7:0] 8 I/O Generic I/O D[8:15] External Data Bus Bits 8 to 15 A[22:0] 23 Output External Address Bus Bits 0 to 22 None None SEL0 1 Output Chip Select for Zone 0 None None SEL1 1 Output Chip Select for Zone 1 None None SEL2 1 Output Chip Select for Zone 2 None None SELIO 1 Output Chip Select for I/O Zone None None WR0 1 Output External Memory Write Low Byte None None WR1 1 Output External Memory Write High Byte None None RD 1 Output External Memory Read None None PE0 1 I/O Generic I/O RXD0 UART0 Receive Data Input PE1 1 I/O Generic I/O TXD0 UART0 Transmit Data Output PE2 1 I/O Generic I/O RTS UART0 Ready-To-Send Output PE3 1 I/O Generic I/O CTS UART0 Clear-To-Send Input CKX UART0 Clock Input PE4 1 I/O Generic I/O TB Multi Function Timer Port B SRFS AAI Receive Frame Sync PE5 1 NMI Non-Maskable Interrupt Input PE6 1 I/O Generic I/O CAN1RX UART Channel 0 Ready-To-Send Output PE7 1 I/O Generic I/O CAN1TX UART Channel 0 Clear-To-Send Input MSK SPI Shift Clock PF0 1 I/O Generic I/O TIO1 Versatile Timer Channel 1 MDIDO SPI Master In Slave Out PF1 1 TIO2 Versatile Timer Channel 2 MDODI SPI Master Out Slave In PF2 1 TIO3 Versatile Timer Channel 3 MWCS SPI Slave Select Input PF3 1 TIO4 Versatile Timer Channel 4 SCK AAI Clock PF4 1 TIO5 Versatile Timer Channel 5 SFS AAI Frame Synchronization PF5 1 TIO6 Versatile Timer Channel 6 STD AAI Transmit Data Output PF6 1 TIO7 Versatile Timer Channel 7 SRD AAI Receive Data Input PF7 1 TIO8 Versatile Timer Channel 8 I/O I/O I/O I/O I/O I/O I/O I/O Primary Function Alternate Function Pins Generic I/O Generic I/O Generic I/O Generic I/O Generic I/O Generic I/O Generic I/O Generic I/O 13 www.national.com CP3CN23 I/O Alternate Name Name CP3CN23 Pins PG0 1 I/O Generic I/O None None PG1 1 I/O Generic I/O None None PG2 1 I/O Generic I/O SRCLK AAI Receive Clock PG3 1 I/O Generic I/O None None PG4 1 I/O Generic I/O None None PG5 1 I/O Generic I/O None None PG6 1 I/O Generic I/O WUI10 Multi-Input Wake-Up Channel 10 PG7 1 I/O Generic I/O TA Multi Function Timer Port A RXD1 UART Channel 1 Receive Data Input PH0 1 I/O Generic I/O WUI11 Multi-Input Wake-Up Channel 11 TXD1 UART Channel 1 Transmit Data Output PH1 1 WUI12 Multi-Input Wake-Up Channel 12 RXD2 UART Channel 2 Receive Data Input PH2 1 WUI13 Multi-Input Wake-Up Channel 13 TXD2 UART Channel 2 Transmit Data Output PH3 1 WUI14 Multi-Input Wake-Up Channel 14 RXD3 UART Channel 3 Receive Data Input PH4 1 WUI15 Multi-Input Wake-Up Channel 15 TXD3 UART Channel 3 Transmit Data Output PH5 1 WUI16 Multi-Input Wake-Up Channel 16 CAN0RX CAN Receive Input PH6 1 WUI17 Multi-Input Wake-Up Channel 17 PH7 1 I/O Generic I/O CAN0TX CAN Transmit Output PJ0 1 I/O Generic I/O WUI18 Multi-Input Wake-Up Channel 18 ASYNC Start Convert Signal to ADC PJ7 1 I/O Generic I/O WUI9 Multi-Input Wake-Up Channel 9 www.national.com I/O Alternate Name Name I/O I/O I/O I/O I/O I/O Primary Function Alternate Function Generic I/O Generic I/O Generic I/O Generic I/O Generic I/O Generic I/O 14 CPU Architecture The CP3CN23 uses the CR16C third-generation 16-bit CompactRISC processor core. The CPU implements a Reduced Instruction Set Computer (RISC) architecture that allows an effective execution rate of up to one instruction per clock cycle. For a detailed description of the CPU16C architecture, see the CompactRISC CR16C Programmer’s Reference Manual which is available on the National Semiconductor web site (http://www.nsc.com). The CR16C CPU core includes these internal registers: General-purpose registers (R0-R13, RA, and SP) Dedicated address registers (PC, ISP, USP, and INTBASE) Processor Status Register (PSR) Configuration Register (CFG) The R0-R11, PSR, and CFG registers are 16 bits wide. The R12, R13, RA, SP, ISP and USP registers are 32 bits wide. The PC register is 24 bits wide. Figure 2 shows the CPU registers. Dedicated Address Registers 15 0 23 31 PC ISPH ISPL USPH USPL INTBASEH INTBASEL General-Purpose Registers 15 0 Processor Status Register 15 0 PSR Configuration Register 15 0 CFG 31 When the CFG.SR bit is clear, register pairs are grouped in the manner used by native CR16C software: (R1,R0), (R2,R1) ... (R11,R10), (R12_L, R11), R12, R13, RA, SP. R12, R13, RA, and SP are 32-bit registers for holding addresses greater than 16 bits. With the recommended calling convention for the architecture, some of these registers are assigned special hardware and software functions. Registers R0 to R13 are for generalpurpose use, such as holding variables, addresses, or index values. The SP register holds a pointer to the program runtime stack. The RA register holds a subroutine return address. The R12 and R13 registers are available to hold base addresses used in the index addressing mode. If a general-purpose register is specified by an operation that is 8 bits long, only the lower byte of the register is used; the upper part is not referenced or modified. Similarly, for word operations on register pairs, only the lower word is used. The upper word is not referenced or modified. 5.2 DEDICATED ADDRESS REGISTERS R0 R1 R2 R3 R4 R5 R6 R7 R8 R9 R10 R11 R12 R13 The CR16C has four dedicated address registers to implement specific functions: the PC, ISP, USP, and INTBASE registers. RA SP 5.2.2 5.2.1 Program Counter (PC) Register The 24-bit value in the PC register points to the first byte of the instruction currently being executed. CR16C instructions are aligned to even addresses, therefore the least significant bit of the PC is always 0. At reset, the PC is initialized to 0 or an optional predetermined value. When a warm reset occurs, value of the PC prior to reset is saved in the (R1,R0) general-purpose register pair. Interrupt Stack Pointer (ISP) The 32-bit ISP register points to the top of the interrupt stack. This stack is used by hardware to service exceptions (interrupts and traps). The stack pointer may be accessed Figure 2. CPU Registers as the ISP register for initialization. The interrupt stack can Some register bits are designated as “reserved.” Software be located anywhere in the CPU address space. The ISP must write a zero to these bit locations when it writes to the cannot be used for any purpose other than the interrupt register. Read operations from reserved bit locations return stack, which is used for automatic storage of the CPU registers when an exception occurs and restoration of these undefined values. registers when the exception handler returns. The interrupt 5.1 GENERAL-PURPOSE REGISTERS stack grows downward in memory. The least significant bit The CompactRISC CPU features 16 general-purpose regis- and the 8 most significant bits of the ISP register are always ters. These registers are used individually as 16-bit oper- 0. ands or as register pairs for operations on addresses 5.2.3 User Stack Pointer (USP) greater than 16 bits. The USP register points to the top of the user-mode pro General-purpose registers are defined as R0 through gram stack. Separate stacks are available for user and suR13, RA, and SP. pervisor modes, to support protection mechanisms for Registers are grouped into pairs based on the setting of multitasking software. The processor mode is controlled by the Short Register bit in the Configuration Register the U bit in the PSR register (which is called PSR.U in the (CFG.SR). When the CFG.SR bit is set, the grouping of shorthand convention). Stack grow downward in memory. If register pairs is upward-compatible with the architecture the USP register points to an illegal address (any address of the earlier CR16A/B CPU cores: (R1,R0), (R2,R1) ... greater than 0x00FF_FFFF) and the USP is used for stack (R11,R10), (R12_L, R11), (R13_L, R12_L), (R14_L, access, an IAD trap is taken. R13_L) and SP. (R14_L, R13_L) is the same as (RA,ERA). DS004 15 www.national.com CP3CN23 5.0 CP3CN23 5.2.4 Interrupt Base Register (INTBASE) N The INTBASE register holds the address of the dispatch table for exceptions. The dispatch table can be located anywhere in the CPU address space. When loading the INTBASE register, bits 31 to 24 and bit 0 must written with 0. 5.3 PROCESSOR STATUS REGISTER (PSR) E The PSR provides state information and controls operating modes for the CPU. The format of the PSR is shown below. 15 12 11 10 9 Reserved C T L U F Z I P E 8 7 6 5 4 3 2 0 N Z F 0 U L 1 0 T C The Carry bit indicates whether a carry or borrow occurred after addition or subtraction. 0 – No carry or borrow occurred. 1 – Carry or borrow occurred. The Trace bit enables execution tracing, in which a Trace trap (TRC) is taken after every instruction. Tracing is automatically disabled during the execution of an exception handler. 0 – Tracing disabled. 1 – Tracing enabled. The Low bit indicates the result of the last comparison operation, with the operands interpreted as unsigned integers. 0 – Second operand greater than or equal to first operand. 1 – Second operand less than first operand. The User Mode bit controls whether the CPU is in user or supervisor mode. In supervisor mode, the SP register is used for stack operations. In user mode, the USP register is used instead. User mode is entered by executing the Jump USR instruction. When an exception is taken, the exception handler automatically begins execution in supervisor mode. The USP register is accessible using the Load Processor Register (LPR/LPRD) instruction in supervisor mode. In user mode, an attempt to access the USP register generates a UND trap. 0 – CPU is executing in supervisor mode. 1 – CPU is executing in user mode. The Flag bit is a general condition flag for signalling exception conditions or distinguishing the results of an instruction, among other thing uses. For example, integer arithmetic instructions use the F bit to indicate an overflow condition after an addition or subtraction operation. The Zero bit is used by comparison operations. In a comparison of integers, the Z bit is set if the two operands are equal. If the operands are unequal, the Z bit is cleared. 0 – Source and destination operands unequal. 1 – Source and destination operands equal. www.national.com 16 P I The Negative bit indicates the result of the last comparison operation, with the operands interpreted as signed integers. 0 – Second operand greater than or equal to first operand. 1 – Second operand less than first operand. The Local Maskable Interrupt Enable bit enables or disables maskable interrupts. If this bit and the Global Maskable Interrupt Enable (I) bit are both set, all interrupts are enabled. If either of these bits is clear, only the nonmaskable interrupt is enabled. The E bit is set by the Enable Interrupts (EI) instruction and cleared by the Disable Interrupts (DI) instruction. 0 – Maskable interrupts disabled. 1 – Maskable interrupts enabled. The Trace Trap Pending bit is used together with the Trace (T) bit to prevent a Trace (TRC) trap from occurring more than once for one instruction. At the beginning of the execution of an instruction, the state of the T bit is copied into the P bit. If the P bit remains set at the end of the instruction execution, the TRC trap is taken. 0 – No trace trap pending. 1 – Trace trap pending. The Global Maskable Interrupt Enable bit is used to enable or disable maskable interrupts. If this bit and the Local Maskable Interrupt Enable (E) bit are both set, all maskable interrupts are taken. If either bit is clear, only the non-maskable interrupt is taken. Unlike the E bit, the I bit is automatically cleared when an interrupt occurs and automatically set upon completion of an interrupt handler. 0 – Maskable interrupts disabled. 1 – Maskable interrupts enabled. Bits Z, C, L, N, and F of the PSR are referenced from assembly language by the condition code in conditional branch instructions. A conditional branch instruction may cause a branch in program execution, based on the value of one or more of these PSR bits. For example, one of the Bcond instructions, BEQ (Branch EQual), causes a branch if the PSR.Z bit is set. On reset, bits 0 through 11 of the PSR are cleared, except for the PSR.E bit, which is set. On warm reset, the values of each bit before reset are copied into the R2 general-purpose register. Bits 4 and 8 of the PSR have a constant value of 0. Bits 12 through 15 are reserved. In general, status bits are modified only by specific instructions. Otherwise, status bits maintain their values throughout instructions which do not implicitly affect them. CP3CN23 5.4 CONFIGURATION REGISTER (CFG) The CFG register is used to enable or disable various operating modes and to control optional on-chip caches. Because the CP3CN23 does not have cache memory, the cache control bits in the CFG register are reserved. All CFG bits are cleared on reset. 15 10 9 Reserved ED SR 8 7 6 SR ED 0 0 5 2 Reserved 1 0 0 0 The Extended Dispatch bit selects whether the size of an entry in the interrupt dispatch table (IDT) is 16 or 32 bits. Each entry holds the address of the appropriate exception handler. When the IDT has 16-bit entries, and all exception handlers must reside in the first 128K of the address space. The location of the IDT is held in the INTBASE register, which is not affected by the state of the ED bit. 0 – Interrupt dispatch table has 16-bit entries. 1 – Interrupt dispatch table has 32-bit entries. The Short Register bit enables a compatibility mode for the CR16B large model. In the CR16C core, registers R12, R13, and RA are extended to 32 bits. In the CR16B large model, only the lower 16 bits of these registers are used, and these “short registers” are paired together for 32-bit operations. In this mode, the (RA, R13) register pair is used as the extended RA register, and address displacements relative to a single register are supported with offsets of 0 and 14 bits in place of the index addressing with these displacements. 0 – 32-bit registers are used. 1 – 16-bit registers are used (CR16B mode). 17 www.national.com CP3CN23 5.5 ADDRESSING MODES The CR16C CPU core implements a load/store architecture, in which arithmetic and logical instructions operate on register operands. Memory operands are made accessible in registers using load and store instructions. For efficient implementation of I/O-intensive embedded applications, the architecture also provides a set of bit operations that operate on memory operands. The load and store instructions support these addressing modes: register/pair, immediate, relative, absolute, and index addressing. When register pairs are used, the lower bits are in the lower index register and the upper bits are in the higher index register. When the CFG.SR bit is clear, the 32bit registers R12, R13, RA, and SP are also treated as register pairs. References to register pairs in assembly language use parentheses. With a register pair, the lower numbered register pair must be on the right. For example, jump (r5, r4) load $4(r4,r3), (r6,r5) load $5(r12), (r13) The instruction set supports the following addressing modes: Register/Pair Mode In register/pair mode, the operand is held in a general-purpose register, or in a general-purpose register pair. For example, the following instruction adds the contents of the low byte of register r1 to the contents of the low byte of r2, and places the result in the low byte register r2. The high byte of register r2 is not modified. ADDB R1, R2 Immediate In immediate mode, the operand is a conMode stant value which is encoded in the instruction. For example, the following instruction multiplies the value of r4 by 4 and places the result in r4. MULW $4, R4 Relative Mode In relative mode, the operand is addressed using a relative value (displacement) encoded in the instruction. This displacement is relative to the current Program Counter (PC), a general-purpose register, or a register pair. For relative mode operands, the memory address is calculated by adding the value of a register pair and a displacement to the base address. The displacement can be a 14 or 20-bit unsigned value, which is encoded in the instruction. For absolute mode operands, the memory address is calculated by adding a 20-bit absolute address encoded in the instruction to the base address. In the following example, the operand address is the sum of the displacement 4, the contents of the register pair (r5,r4), and the base address held in register r12. The word at this address is loaded into register r6. LOADW [r12]4(r5, r4), r6 Absolute Mode In absolute mode, the operand is located in memory, and its address is encoded in the instruction (normally 20 or 24 bits). For example, the following instruction loads the byte at address 4000 into the lower 8 bits of register r6. LOADB 4000, r6 For additional information on the addressing modes, see the CompactRISC CR16C Programmer's Reference Manual. In branch instructions, the displacement is always relative to the current value of the PC Register. For example, the following instruction causes an unconditional branch to an address 10 ahead of the current PC. BR *+10 www.national.com Index Mode In another example, the operand resides in memory. Its address is obtained by adding a displacement encoded in the instruction to the contents of register r5. The address calculation does not modify the contents of register r5. LOADW 12(R5), R6 The following example calculates the address of a source operand by adding a displacement of 4 to the contents of a register pair (r5, r4) and loads this operand into the register pair (r7, r6). r7 receives the high word of the operand, and r6 receives the low word. LOADD 4(r5, r4), (r7, r6) In index mode, the operand address is calculated with a base address held in either R12 or R13. The CFG.SR bit must be clear to use this mode. 18 STACKS 5.7 A stack is a last-in, first-out data structure for dynamic storage of data and addresses. A stack consists of a block of memory used to hold the data and a pointer to the top of the stack. As more data is pushed onto a stack, the stack grows downward in memory. The CR16C supports two types of stacks: the interrupt stack and program stacks. INSTRUCTION SET Table 4 lists the operand specifiers for the instruction set, and Table 5 is a summary of all instructions. For each instruction, the table shows the mnemonic and a brief description of the operation performed. In the mnemonic column, the lower-case letter “i” is used to indicate the type of integer that the instruction operates on, either “B” for byte or “W” for word. For example, the notation 5.6.1 Interrupt Stack ADDi for the “add” instruction means that there are two The processor uses the interrupt stack to save and restore forms of this instruction, ADDB and ADDW, which operate the program state during the exception handling. Hardware on bytes and words, respectively. automatically pushes this data onto the interrupt stack before entering an exception handler. When the exception Similarly, the lower-case string “cond” is used to indicate the handler returns, hardware restores the processor state with type of condition tested by the instruction. For example, the data popped from the interrupt stack. The interrupt stack notation Jcond represents a class of conditional jump instructions: JEQ for Jump on Equal, JNE for Jump on Not pointer is held in the ISP register. Equal, etc. For detailed information on all instructions, see 5.6.2 Program Stack the CompactRISC CR16C Programmer's Reference ManuThe program stack is normally used by software to save and al. restore register values on subroutine entry and exit, hold loTable 4 Key to Operand Specifiers cal and temporary variables, and hold parameters passed between the calling routine and the subroutine. The only Operand Specifier Description hardware mechanisms which operate on the program stack are the PUSH, POP, and POPRET instructions. abs Absolute address 5.6.3 User and Supervisor Stack Pointers To support multitasking operating systems, support is provided for two program stack pointers: a user stack pointer and a supervisor stack pointer. When the PSR.U bit is clear, the SP register is used for all program stack operations. This is the default mode when the user/supervisor protection mechanism is not used, and it is the supervisor mode when protection is used. When the PSR.U bit is set, the processor is in user mode, and the USP register is used as the program stack pointer. User mode can only be entered using the JUSR instruction, which performs a jump and sets the PSR.U bit. User mode is exited when an exception is taken and re-entered when the exception handler returns. In user mode, the LPRD instruction cannot be used to change the state of processor registers (such as the PSR). 19 disp Displacement (numeric suffix indicates number of bits) imm Immediate operand (numeric suffix indicates number of bits) Iposition Bit position in memory Rbase Base register (relative mode) Rdest Destination register Rindex Index register RPbase, RPbasex Base register pair (relative mode) RPdest Destination register pair RPlink Link register pair Rposition Bit position in register Rproc 16-bit processor register Rprocd 32-bit processor register RPsrc Source register pair RPtarget Target register pair Rsrc, Rsrc1, Rsrc2 Source register www.national.com CP3CN23 5.6 CP3CN23 Table 5 Instruction Set Summary Mnemonic Operands Description MOVi Rsrc/imm, Rdest Move MOVXB Rsrc, Rdest Move with sign extension MOVZB Rsrc, Rdest Move with zero extension MOVXW Rsrc, RPdest Move with sign extension MOVZW Rsrc, RPdest Move with zero extension MOVD imm, RPdest Move immediate to register-pair RPsrc, RPdest Move between register-pairs ADD[U]i Rsrc/imm, Rdest Add ADDCi Rsrc/imm, Rdest Add with carry ADDD RPsrc/imm, RPdest Add with RP or immediate. MACQWa Rsrc1, Rsrc2, RPdest Multiply signed Q15: RPdest := RPdest + (Rsrc1 × Rsrc2) MACSWa Rsrc1, Rsrc2, RPdest Multiply signed and add result: RPdest := RPdest + (Rsrc1 × Rsrc2) MACUWa Rsrc1, Rsrc2, RPdest Multiply unsigned and add result: RPdest := RPdest + (Rsrc1 × Rsrc2) MULi Rsrc/imm, Rdest Multiply: Rdest(8) := Rdest(8) × Rsrc(8)/imm Rdest(16) := Rdest(16) × Rsrc(16)/imm MULSB Rsrc, Rdest Multiply: Rdest(16) := Rdest(8) × Rsrc(8) MULSW Rsrc, RPdest Multiply: RPdest := RPdest(16) × Rsrc(16) MULUW Rsrc, RPdest Multiply: RPdest := RPdest(16) × Rsrc(16); SUBi Rsrc/imm, Rdest Subtract: (Rdest := Rdest - Rsrc/imm) SUBD RPsrc/imm, RPdest Subtract: (RPdest := RPdest - RPsrc/imm) SUBCi Rsrc/imm, Rdest Subtract with carry: (Rdest := Rdest - Rsrc/imm) CMPi Rsrc/imm, Rdest Compare Rdest - Rsrc/imm CMPD RPsrc/imm, RPdest Compare RPdest - RPsrc/imm BEQ0i Rsrc, disp Compare Rsrc to 0 and branch if EQUAL BNE0i Rsrc, disp Compare Rsrc to 0 and branch if NOT EQUAL ANDi Rsrc/imm, Rdest Logical AND: Rdest := Rdest & Rsrc/imm ANDD RPsrc/imm, RPdest Logical AND: RPdest := RPsrc & RPsrc/imm ORi Rsrc/imm, Rdest Logical OR: Rdest := Rdest | Rsrc/imm ORD RPsrc/imm, RPdest Logical OR: Rdest := RPdest | RPsrc/imm Scond Rdest Save condition code as boolean XORi Rsrc/imm, Rdest Logical exclusive OR: Rdest := Rdest ^ Rsrc/imm XORD RPsrc/imm, RPdest Logical exclusive OR: Rdest := RPdest ^ RPsrc/imm ASHUi Rsrc/imm, Rdest Arithmetic left/right shift www.national.com 20 CP3CN23 Table 5 Instruction Set Summary Mnemonic Operands Description ASHUD Rsrc/imm, RPdest Arithmetic left/right shift LSHi Rsrc/imm, Rdest Logical left/right shift LSHD Rsrc/imm, RPdest Logical left/right shift SBITi Iposition, disp(Rbase) Set a bit in memory (Because this instruction treats the destination as a readmodify-write operand, it not be used to set bits in writeonly registers.) Iposition, disp(RPbase) Iposition, (Rindex)disp(RPbasex) Iposition, abs Iposition, (Rindex)abs CBITi Iposition, disp(Rbase) Clear a bit in memory Iposition, disp(RPbase) Iposition, (Rindex)disp(RPbasex) Iposition, abs Iposition, (Rindex)abs TBIT TBITi Rposition/imm, Rsrc Test a bit in a register Test a bit in memory Iposition, disp(Rbase) Iposition, disp(RPbase) Iposition, (Rindex)disp(RPbasex) Iposition, abs Iposition, (Rindex)abs LPR Rsrc, Rproc Load processor register LPRD RPsrc, Rprocd Load double processor register SPR Rproc, Rdest Store processor register SPRD Rprocd, RPdest Store 32-bit processor register Bcond disp9 Conditional branch disp17 disp24 BAL RPlink, disp24 Branch and link BR disp9 Branch disp17 disp24 EXCP vector Trap (vector) Jcond RPtarget Conditional Jump to a large address JAL RA, RPtarget, Jump and link to a large address RPlink, RPtarget JUMP RPtarget Jump JUSR RPtarget Jump and set PSR.U 21 www.national.com CP3CN23 Table 5 Instruction Set Summary Mnemonic Operands Description RETX Return from exception PUSH imm, Rsrc, RA Push “imm” number of registers on user stack, starting with Rsrc and possibly including RA POP imm, Rdest, RA Restore “imm” number of registers from user stack, starting with Rdest and possibly including RA POPRET imm, Rdest, RA Restore registers (similar to POP) and JUMP RA LOADi disp(Rbase), Rdest Load (register relative) abs, Rdest Load (absolute) (Rindex)abs, Rdest Load (absolute index relative) (Rindex)disp(RPbasex), Rdest Load (register relative index) disp(RPbase), Rdest Load (register pair relative) disp(Rbase), Rdest Load (register relative) abs, Rdest Load (absolute) (Rindex)abs, Rdest Load (absolute index relative) (Rindex)disp(RPbasex), Rdest Load (register pair relative index) disp(RPbase), Rdest Load (register pair relative) Rsrc, disp(Rbase) Store (register relative) Rsrc, disp(RPbase) Store (register pair relative) Rsrc, abs Store (absolute) Rsrc, (Rindex)disp(RPbasex) Store (register pair relative index) Rsrc, (Rindex)abs Store (absolute index) RPsrc, disp(Rbase) Store (register relative) RPsrc, disp(RPbase) Store (register pair relative) RPsrc, abs Store (absolute) RPsrc, (Rindex)disp(RPbasex) Store (register pair index relative) RPsrc, (Rindex)abs Store (absolute index relative) imm4, disp(Rbase) Store unsigned 4-bit immediate value extended to operand length in memory LOADD STORi STORD STOR IMM imm4, disp(RPbase) imm4, (Rindex)disp(RPbasex) imm4, abs imm4, (Rindex)abs LOADM imm3 Load 1 to 8 registers (R2-R5, R8-R11) from memory starting at (R0) LOADMP imm3 Load 1 to 8 registers (R2-R5, R8-R11) from memory starting at (R1, R0) STORM STORM imm3 Store 1 to 8 registers (R2-R5, R8-R11) to memory starting at (R2) www.national.com 22 Mnemonic STORMP Operands Description imm3 Store 1 to 8 registers (R2-R5, R8-R11) to memory starting at (R7,R6) DI Disable maskable interrupts EI Enable maskable interrupts EIWAIT Enable maskable interrupts and wait for interrupt NOP No operation WAIT Wait for interrupt 23 www.national.com CP3CN23 Table 5 Instruction Set Summary CP3CN23 6.0 Memory The CP3CN23 supports a uniform 16M-byte linear address space. Table 6 lists the types of memory and peripherals that occupy this memory space. Unlisted address ranges are reserved and must not be read or written. The BIU zones are regions of the address space that share the same control bits in the Bus Interface Unit (BIU). Table 6 CP3CN23 Memory Map 6.1 Start Address End Address Size in Bytes 00 0000h 03 FFFFh 256K On-chip Flash Program Memory, including Boot Memory 04 0000h 0C FFFFh 576K Reserved 0D 0000h 0D 1FFFh 8K On-chip Flash Data Memory 0D 2000h 0D FFFFh 56K Reserved 0E 0000h 0E 7FFFh 32K System RAM 0E 8000h 0E EFFFh 28K Reserved 0E F000h 0E F13Fh 320 CAN0 Buffers and Registers 0E F140h 0E F1FFh 192 Reserved 0E F200h 0E F33Fh 320 CAN1 Buffers and Registers 0E F320h 0F FFFFh 67K Reserved 10 0000h 3F FFFFh 3072K Reserved 40 0000h 7F FFFFh 4096K External Memory Zone 1 Static Zone 1 80 0000h FE FFFFh 8128K External Memory Zone 2 Static Zone 2 FF 0000h FF F1FFh 61952 Reserved FF F200h FF F5FFh 1K FF F600h FF FAFFh FF FB00h FF FC00h Description Static Zone 0 (mapped internally in IRE and ERE mode; mapped to the external bus in DEV mode) N/A Peripherals and Other I/O Ports N/A 1280 BIU, DMA, Flash interfaces IN/A FF FBFFh 256 I/O Expansion I/O Zone FF FFFFh 1K Peripherals and Other I/O Ports N/A OPERATING ENVIRONMENT The operating environment controls whether external memory is supported and whether the reset vector jumps to a code space intended to support In-System Programming (ISP). Up to 12M of external memory space is available. The operating mode of the device is controlled by the states on the ENV[2:0] pins at reset and the states of the EMPTY bits in the Protection Word, as shown in Table 7. Internal pullups on the ENV[2:0] pins select IRE mode or ISP mode if these pins are allowed to float. When ENV[2:0] = 111b, IRE mode is selected unless the EMPTY bits in the Protection word indicate that the program flash memory is empty (unprogrammed), in which case ISP mode is selected. When ENV[2:0] = 011b, ERE mode is selected unless the EMPTY bits indicate that the program flash memory is empty, in which case ISP mode is selected. When ENV[2:0] = 110b, ISP mode is selected without regard to the states of the EMPTY bits. See Section 8.4.2 for more details. www.national.com BIU Zone 24 In the DEV environment, the on-chip flash memory is disabled, and the corresponding region of the address space is mapped to external memory. DEVINT mode is equivalent to DEV mode but maps static memory zone 0 to the on-chip memory. Table 7 Operating Environment Selection ENV[2:0] EMPTY 6.2 The BIU has a set of control registers that determine how many wait cycles and hold cycles are to be used for accessing memory. During initialization of the system, these registers should be programmed with appropriate values so that the minimum allowable number of cycles is used. This number varies with the clock frequency. Operating Environment 111 No Internal ROM enabled (IRE) mode 011 No External ROM enabled (ERE) mode 000 N/A Development (DEV) mode 001 N/A Development (DEVINT) mode with internal memory 110 N/A In-System-Programming (ISP) mode 111 Yes In-System-Programming (ISP) mode 011 Yes In-System-Programming (ISP) mode There are five BIU control registers, as listed in Table 8. These registers control the bus cycle configuration used for accessing the various on-chip memory types. Table 8 Bus Control Registers Name Address Description BCFG FF F900h BIU Configuration Register IOCFG FF F902h I/O Zone Configuration Register SZCFG0 FF F904h Static Zone 0 Configuration Register SZCFG1 FF F906h Static Zone 1 Configuration Register SZCFG2 FF F908h Static Zone 2 Configuration Register BUS INTERFACE UNIT (BIU) The BIU controls the interface between the CPU core bus and those on-chip modules which are mapped into BIU zones. These on-chip modules are the flash program memory and the I/O zone. The BIU controls the configured parameters for bus access (such as the number of wait states for memory access) and issues the appropriate bus signals for the requested access. 6.3 BIU CONTROL REGISTERS BUS CYCLES There are four types of data transfer bus cycles: 6.4.1 Normal read Fast read Early write Late write BIU Configuration Register (BCFG) The BCFG register is a byte-wide, read/write register that selects early-write or late-write bus cycles. At reset, the register is initialized to 07h. The register format is shown below. The type of data cycle used in a particular transaction depends on the type of CPU operation (a write or a read), the type of memory or I/O being accessed, and the access type programmed into the BIU control registers (early/late write or normal/fast read). For read operations, a basic normal read takes two clock cycles, and a fast-read bus cycle takes one clock cycle. Normal read bus cycles are enabled by default after reset. For write operations, a basic late-write bus cycle takes two clock cycles, and a basic early-write bus cycle takes three clock cycles. Early-write bus cycles are enabled by default after reset. However, late-write bus cycles are needed for ordinary write operations, so this configuration must be changed by software (see Section 6.4.1). 7 3 Reserved EWR 2 1 0 1 1 EWR The Early Write bit controls write cycle timing. 0 – Late-write operation (2 clock cycles to write). 1 – Early-write operation. At reset, the BCFG register is initialized to 07h, which selects early-write operation. However, late-write operation is required for normal device operation, so software must change the register value to 06h. Bits 1 and 2 of this register must always be set when writing to this register. In certain cases, one or more additional clock cycles are added to a bus access cycle. There are two types of additional clock cycles for ordinary memory accesses, called internal wait cycles (TIW) and hold (Thold) cycles. A wait cycle is inserted in a bus cycle just after the memory address has been placed on the address bus. This gives the accessed memory more time to respond to the transaction request. A hold cycle is inserted at the end of a bus cycle. This holds the data on the data bus for an extended number of clock cycles. 25 www.national.com CP3CN23 6.4 CP3CN23 6.4.2 I/O Zone Configuration Register (IOCFG) 6.4.3 The IOCFG register is a word-wide, read/write register that controls the timing and bus characteristics of accesses to the 256-byte I/O Zone memory space (FF FB00h to FF FBFFh). The registers associated with Port B and Port C reside in the I/O memory array. At reset, the register is initialized to 069Fh. The register format is shown below. 7 BW 6 5 Reserved 4 3 2 HOLD 15 The SZCFG0 register is a word-wide, read/write register that controls the timing and bus characteristics of Zone 0 memory accesses. Zone 0 is used for the on-chip flash memory (including the boot area, program memory, and data memory). At reset, the register is initialized to 069Fh. The register format is shown below. 0 WAIT 10 Reserved Static Zone 0 Configuration Register (SZCFG0) 9 8 IPST Res. 7 6 5 BW WBR RBE 15 HOLD BW IPST The Memory Wait Cycles field specifies the number of TIW (internal wait state) clock cycles added for each memory access, ranging from 000 binary for no additional TIW wait cycles to 111 binary for seven additional TIW wait cycles. The Memory Hold Cycles field specifies the number of Thold clock cycles used for each memory access, ranging from 00b for no Thold cycles to 11b for three Thold clock cycles. The Bus Width bit defines the bus width of the IO Zone. 0 – 8-bit bus width. 1 – 16-bit bus width (default) The Post Idle bit controls whether an idle cycle follows the current bus cycle, when the next bus cycle accesses a different zone. No idle cycles are required for on-chip accesses. 0 – No idle cycle (recommended). 1 – Idle cycle. WAIT HOLD RBE WBR BW FRE IPST www.national.com 26 3 2 HOLD 12 Reserved WAIT 4 11 FRE 0 WAIT 10 9 IPRE IPST 8 Res. The Memory Wait field specifies the number of TIW (internal wait state) clock cycles added for each memory access, ranging from 000b for no additional TIW wait cycles to 111b for seven additional TIW wait cycles. These bits are ignored if the SZCFG0.FRE bit is set. The Memory Hold field specifies the number of Thold clock cycles used for each memory access, ranging from 00b for no Thold cycles to 11b for three Thold clock cycles. These bits are ignored if the SZCFG0.FRE bit is set. The Read Burst Enable enables burst cycles on 16-bit reads from 8-bit bus width regions of the address space. Because the flash program memory is required to be 16-bit bus width, the RBE bit is a don’t care bit. This bit is ignored when the SZCFG0.FRE bit is set. 0 – Burst read disabled. 1 – Burst read enabled. The Wait on Burst Read bit controls if a wait state is added on burst read transaction. This bit is ignored, when SZCFG0.FRE bit is set or when SZCFG0.RBE is clear. 0 – No TBW on burst read cycles. 1 – One TBW on burst read cycles. The Bus Width bit controls the bus width of the zone. The flash program memory must be configured for 16-bit bus width. 0 – 8-bit bus width. 1 – 16-bit bus width (required). The Fast Read Enable bit controls whether fast read bus cycles are used. A fast read operation takes one clock cycle. A normal read operation takes at least two clock cycles. 0 – Normal read cycles. 1 – Fast read cycles. The Post Idle bit controls whether an idle cycle follows the current bus cycle, when the next bus cycle accesses a different zone. No idle cycles are required for on-chip accesses. 0 – No idle cycle (recommended). 1 – Idle cycle inserted. 6.4.4 The Preliminary Idle bit controls whether an idle cycle is inserted prior to the current bus cycle, when the new bus cycle accesses a different zone. No idle cycles are required for onchip accesses. 0 – No idle cycle (recommended). 1 – Idle cycle inserted. At reset, the register is initialized to 069Fh. The register format is shown below. 7 6 5 BW WBR RBE 15 RBE WBR BW FRE 4 3 2 HOLD 12 Reserved HOLD IPRE The Post Idle bit controls whether an idle cycle follows the current bus cycle, when the next bus cycle accesses a different zone. 0 – No idle cycle. 1 – Idle cycle inserted. The Preliminary Idle bit controls whether an idle cycle is inserted prior to the current bus cycle, when the new bus cycle accesses a different zone. 0 – No idle cycle. 1 – Idle cycle inserted. 6.4.5 Static Zone 2 Configuration Register (SZCFG2) Static Zone 1 Configuration Register (SZCFG1) The SZCFG1 register is a word-wide, read/write register that controls the timing and bus characteristics for off-chip accesses selected with the SEL1 output signal. WAIT IPST 11 FRE 0 At reset, the register is initialized to 069Fh. The register format is shown below. WAIT 10 9 IPRE IPST The SZCFG2 register is a word-wide, read/write register that controls the timing and bus characteristics for off-chip accesses selected with the SEL2 output signal. 8 Res. The Memory Wait field specifies the number of TIW (internal wait state) clock cycles added for each memory access, ranging from 000b for no additional TIW wait cycles to 111b for seven additional TIW wait cycles. These bits are ignored if the SZCFG1.FRE bit is set. The Memory Hold field specifies the number of Thold clock cycles used for each memory access, ranging from 00b for no Thold cycles to 11b for three Thold clock cycles. These bits are ignored if the SZCFG1.FRE bit is set. The Read Burst Enable enables burst cycles on 16-bit reads from 8-bit bus width regions of the address space. This bit is ignored when the SZCFG1.FRE bit is set or the SZCFG1.BW is clear. 0 – Burst read disabled. 1 – Burst read enabled. The Wait on Burst Read bit controls if a wait state is added on burst read transaction. This bit is ignored, when SZCFG1.FRE bit is set or when SZCFG1.RBE is clear. 0 – No TBW on burst read cycles. 1 – One TBW on burst read cycles. The Bus Width bit controls the bus width of the zone. 0 – 8-bit bus width. 1 – 16-bit bus width. The Fast Read Enable bit controls whether fast read bus cycles are used. A fast read operation takes one clock cycle. A normal read operation takes at least two clock cycles. 0 – Normal read cycles. 1 – Fast read cycles. 7 6 5 BW WBR RBE 15 HOLD RBE WBR BW 27 3 2 HOLD 12 Reserved WAIT 4 11 FRE 0 WAIT 10 9 IPRE IPST 8 Res. The Memory Wait field specifies the number of TIW (internal wait state) clock cycles added for each memory access, ranging from 000b for no additional TIW wait cycles to 111b for seven additional TIW wait cycles. These bits are ignored if the SZCFG2.FRE bit is set. The Memory Hold field specifies the number of Thold clock cycles used for each memory access, ranging from 00b for no Thold cycles to 11b for three Thold clock cycles. These bits are ignored if the SZCFG2.FRE bit is set. The Read Burst Enable enables burst cycles on 16-bit reads from 8-bit bus width regions of the address space. This bit is ignored when the SZCFG2.FRE bit is set or the SZCFG2.BW is clear. 0 – Burst read disabled. 1 – Burst read enabled. The Wait on Burst Read bit controls if a wait state is added on burst read transaction. This bit is ignored, when SZCFG2.FRE bit is set or when SZCFG2.RBE is clear. 0 – No TBW on burst read cycles. 1 – One TBW on burst read cycles. The Bus Width bit controls the bus width of the zone. 0 – 8-bit bus width. 1 – 16-bit bus width. www.national.com CP3CN23 IPRE CP3CN23 FRE IPST IPRE The Fast Read Enable bit controls whether fast read bus cycles are used. A fast read operation takes one clock cycle. A normal read operation takes at least two clock cycles. 0 – Normal read cycles. 1 – Fast read cycles. The Post Idle bit controls whether an idle cycle follows the current bus cycle, when the next bus cycle accesses a different zone. 0 – No idle cycle. 1 – Idle cycle inserted. The Preliminary Idle bit controls whether an idle cycle is inserted prior to the current bus cycle, when the new bus cycle accesses a different zone. 0 – No idle cycle. 1 – Idle cycle inserted. 6.5 WAIT AND HOLD STATES The number of wait cycles and hold cycles inserted into a bus cycle depends on whether it is a read or write operation, the type of memory or I/O being accessed, and the control register settings. 6.5.1 Flash Program/Data Memory When the CPU accesses the Flash program and data memory (address ranges 000000h–03FFFFh and 0E0000h– 0E1FFFh), the number of added wait and hold cycles depends on the type of access and the BIU register settings. In fast-read mode (SZCFG0.FRE=1), a read operation is a single cycle access. This limits the maximum CPU operating frequency to 24 MHz. For a read operation in normal-read mode (SZCFG0.FRE=0), the number of inserted wait cycles is specified in the SZCFG0.WAIT field. The total number of wait cycles is the value in the WAIT field plus 1, so it can range from 1 to 8. The number of inserted hold cycles is specified in the SCCFG0.HOLD field, which can range from 0 to 3. For a write operation in fast read mode (SZCFG0.FRE=1), the number of inserted wait cycles is 1. No hold cycles are used. For a write operation normal read mode (SZCFG0.FRE=0), the number of wait cycles is equal to the value written to the SZCFG0.WAIT field plus 1 (in the late write mode) or 2 (in the early write mode). The number of inserted hold cycles is equal to the value written to the SCCFG0.HOLD field, which can range from 0 to 3. 6.5.2 RAM Memory Read and write accesses to on-chip RAM is performed within a single cycle, without regard to the BIU settings. The RAM address is in the range of 0E 0000h–0E 7FFFh and 0E 8000h–0E 91FFh. 6.5.3 Access to Peripherals When the CPU accesses on-chip peripherals in the range of 0E F000h–0E F1FFh and FF 0000h–FF FBFFh, one wait cycle and one preliminary idle cycle is used. No hold cycles are used. The IOCFG register determines the access timing for the address range FF FB00h–FF FBFFh. www.national.com 28 System Configuration Registers The system configuration registers control and provide status for certain aspects of device setup and operation, such as indicating the states sampled from the ENV[2:0] inputs. The system configuration registers are listed in Table 9. Table 9 System Configuration Registers Name Address Description MCFG FF F910h Module Configuration Register MSTAT FF F914h Module Status Register 7.1 MODULE CONFIGURATION REGISTER (MCFG) The MCFG register is a byte-wide, read/write register that selects the clock output features of the device. The register must be written in active mode only, not in power save, HALT, or IDLE mode. However, the register contents are preserved during all power modes. The MCFG register format is shown below. 7 Res. 6 5 4 3 2 1 0 MEM_IO_ MISC_IO_ SCLK MCLK PLLCLK EXI Res. SPEED SPEED OE OE OE OE EXIOE The EXIOE bit controls whether the external bus is enabled in the IRE environment for implementing the I/O Zone (FF FB00h–FF FBFFh). 0 – External bus disabled. 1 – External bus enabled. PLLCLKOE The PLLCLKOE bit controls whether the PLL clock is driven on the ENV0/PLLCLK pin. 0 – ENV0/PLLCLK pin is high impedance. 1 – PLL clock driven on the ENV0/PLLCLK pin. MCLKOE The MCLKOE bit controls whether the Main Clock is driven on the ENV1/CPUCLK pin. 0 – ENV1/CPUCLK pin is high impedance. 1 – Main Clock is driven on the ENV1/CPUCLK pin. SCLKOE The SCLKOE bit controls whether the Slow Clock is driven on the ENV2/SLOWCLK pin. 0 – ENV2/SLOWCLK pin is high impedance. 1 – Slow Clock is driven on the ENV2/SLOWCLK pin. MISC_IO_SPEED The MISC_IO_SPEED bit controls the slew rate of the output drivers for the ENV[2:0], RDY, and TDO pins. To minimize noise, the slow slew rate is recommended. 0 – Fast slew rate. 1 – Slow slew rate. MEM_IO_SPEED The MEM_IO_SPEED bit controls the slew rate of the output drivers for the A[22:0], RD, SEL[2:0], SELIO, WR[1:0], PB[7:0], and PC[7:0] pins. Memory speeds for the CP3CN23 are characterized with fast slew rate. Slow slew rate reduces the available memory access time by 5 ns. 0 – Fast slew rate. 1 – Slow slew rate. 29 www.national.com CP3CN23 7.0 CP3CN23 7.2 MODULE STATUS REGISTER (MSTAT) 7.3 SOFTWARE RESET REGISTER (SWRESET) The MSTAT register is a byte-wide, read-only register that indicates the general status of the device. The MCFG regis- The SWRESET register is a byte-wide, write-only register ter format is shown below. which provides a mechanism for software to initiate a reset into ISP mode without regard to the status of the EMPTY bits in the flash protection word. This form of reset is only al7 6 5 4 3 2 0 lowed when all of the following conditions are true: ISPRST WDRST Res. DPGMBUSY PGMBUSY OENV2:0 The device is in IRE or ERE mode BOOTAREA is defined (has a value other than 1111b) in the Protection Word (see Section 8.4.2 for more details). OENV2:0 The Operating Environment bits hold the states sampled from the ENV[2:0] input pins ISPE is set in the flash protection word, indicating that there is ISP code in the flash at reset. These states are controlled by external hardware at reset and are held constant in the register until the next reset. PGMBUSY The Flash Programming Busy bit is automatically set when either the program memory or the data memory is being programmed or erased. It is clear when neither of the memories is busy. When this bit is set, software must not attempt to program or erase either of these two memories. This bit is a copy of the FMBUSY bit in the FMSTAT register. 0 – Flash memory is not busy. 1 – Flash memory is busy. DPGMBUSY The Data Flash Programming Busy indicates that the flash data memory is being erased or a pipelined programming sequence is currently ongoing. Software must not attempt to perform any write access to the flash program memory at this time, without also polling the FSMSTAT.FMFULL bit in the flash memory interface. The DPGMBUSY bit is a copy of the FMBUSY bit in the FSMSTAT register. 0 – Flash data memory is not busy. 1 – Flash data memory is busy. WDRST The Watchdog Reset bit indicates that a Watchdog timer reset has occurred. Write a 1 to this bit to clear it. Power-on reset also clears this bit. 0 – No Watchdog timer reset has occurred since this bit was last cleared. 1 – A Watchdog timer reset has occurred since this bit was last cleared. ISPRST The Software ISP Reset bit indicates that a software ISP reset has occurred since the bit was last cleared. This bit is cleared by a SWRESET(CLR) sequence or a power-on reset. 0 – No software ISP reset has occurred since this bit was last cleared. 1 – A software ISP reset has occurred since this bit was last cleared. www.national.com 30 To initiate a reset under these conditions, it is necessary to write the value E1h to the SWRESET register, followed within 127 clock cycles by the value 3Eh. The reset then follows immediately. This sequence is called SWRESET(ISP). Once the device has been reset into ISP mode by SWRESET(ISP), any subsequent reset (other than internal or external power-on reset) will cause the part to reset into ISP mode because the EMPTY bits in the Protection Word continue to be ignored. A second set of special values written to the SWRESET register will cause a reset out of ISP mode (whether or not the device is currently in ISP mode). This can be used as a simple software reset. In this case, no conditions are checked. To initiate reset out of ISP mode, write the value E1h to the SWRESET register, followed within 127 clock cycles by the value 0Eh. The reset then follows immediately. This sequence is called SWRESET(CLR). This reset also cancels the effect of any previous SWRESET(ISP), so subsequent resets will check the EMPTY bits to determine whether to enter ISP mode. The ISP reset behaves similarly to the Watchdog reset, for example, if the flash interface is busy when reset is asserted, the reset to the clock module is delayed until the flash operations are completed. Flash Memory The flash memory consists of the flash program memory and the flash data memory. The flash program memory is further divided into the Boot Area and the Code Area. default (after reset) all bits in the FM0WER, FM1WER, and FSM0WER registers are cleared, which disables write access by the CPU to all sections. Write access to a section is A special protection scheme is applied to the lower portion enabled by setting the corresponding write enable bit. After of the flash program memory, called the Boot Area. The completing a programming or erase operation, software Boot Area always starts at address 0 and ranges up to a should clear all write enable bits to protect the flash program programmable end address. The maximum boot area ad- memory against any unintended writes. dress which can be selected is 00 77FFh. The intended use 8.1.2 Global Protection of this area is to hold In-System-Programming (ISP) rouThe WRPROT field in the Protection Word controls global tines or essential application routines. The Boot Area is alwrite protection. The Protection Word is located in a special ways protected against CPU write access, to avoid flash memory outside of the CPU address space. If a majorunintended modifications. ity of the bits in the 3-bit WRPROT field are clear, write proThe Code Area is intended to hold the application code and tection is enabled. Enabling this mode prevents the CPU constant data. The Code Area begins with the next byte af- from writing to flash memory. ter the Boot Area. Table 10 summarizes the properties of The RDPROT field in the Protection Word controls global the regions of flash memory mapped into the CPU address read protection. If a majority of the bits in the 3-bit RDPROT space. field are clear, read protection is enabled. Enabling this Table 10 Flash Memory Areas mode prevents reading by an external debugger through the serial debug interface or by an external flash programmer. Read Area Address Range Write Access CPU read access is not affected by the RDPROT bits. Access 8.2 Boot Area 0–BOOTAREA - 1 Code BOOTAREA–03 FFFFh Area Data Area 8.1 0D 0000h–0D 1FFFh Yes No Yes Write access only if section write enable bit is set and global write protection is disabled. Yes Write access only if section write enable bit is set and global write protection is disabled. Each of the flash memories are divided into main blocks and information blocks. The main blocks hold the code or data used by application software. The information blocks hold factory parameters, protection settings, and other devicespecific data. The main blocks are mapped into the CPU address space. The information blocks are accessed indirectly through a register-based interface. Separate sets of registers are provided for accessing flash program memory (FM registers) and flash data memory (FSM registers). The flash program memory consists of two main blocks and two data blocks, as shown in Table 11. The flash data memory consists of one main block and one information block. Table 11 Flash Memory Blocks Name Address Range Function Main Block 0 00 0000h–01 FFFFh (CPU address space) Flash Program Memory Information Block 0 000h–07Fh (address register) Function Word, Factory Parameters Main Block 1 02 0000h–03 FFFFh (CPU address space) Flash Program Memory Information Block 1 080h–0FFh (address register) Protection Word, User Data Main Block 2 0D 0000h–0D 1FFFh (CPU address space) Flash Data Memory Information Block 2 000h–07Fh (address register) User Data FLASH MEMORY PROTECTION The memory protection mechanisms provide both global and section-level protection. Section-level protection against CPU writes is applied to individual 8K-byte sections of the flash program memory and 512-byte sections of the flash data memory. Section-level protection is controlled through read/write registers mapped into the CPU address space. Global write protection is applied at the device level, to disable flash memory writes by the CPU. Global write protection is controlled by the encoding of bits stored in the flash memory array. 8.1.1 FLASH MEMORY ORGANIZATION Section-Level Protection Each bit in the Flash Memory Write Enable (FM0WER and FM1WER) registers enables or disables write access to a corresponding section of flash program memory. Write access to the flash data memory is controlled by the bits in the Flash Slave Memory Write Enable (FSM0WER) register. By 31 www.national.com CP3CN23 8.0 CP3CN23 8.2.1 Main Block 0 and 1 8.2.4 Main Block 0 and Main Block 1 hold the 256K-byte program space, which consists of the Boot Area and Code Area. Each block consists of sixteen 8K-byte sections. Write access by the CPU to Main Block 0 and Main Block 1 is controlled by the corresponding bits in the FM0WER and FM1WER registers, respectively. The least significant bit in each register controls the section at the lowest address. 8.2.2 Information Block 0 Information Block 0 contains 128 bytes, of which one 16-bit word has a dedicated function, called the Function Word. The Function Word resides at address 07Eh. The remaining Information Block 0 locations are used to hold factory parameters. Software only has read access to Information Block 0 through a register-based interface. The Function Word and the factory parameters are protected against CPU writes. Table 12 shows the structure of Information Block 0. Table 12 Information Block 0 Address Range Name Function Word Write Access Yes No 000h–07Dh Information Block 1 Table 13 Information Block 1 Protection Word Other (User Data) www.national.com Address Range Read Access Write Access Yes Write access only if section write enable bit is set and global write protection is disabled. 0FEh–0FFh 080h–0FDh 8.2.5 Information Block 2 Information Block 2 contains 128 bytes, which can be used to store user data. The CPU can always read Information Block 2. The CPU can write Information Block 2 only when global write protection is disabled. Erasing Information Block 2 also erases Main Block 2. 8.3 FLASH MEMORY OPERATIONS Flash memory programming (erasing and writing) can be performed on the flash data memory while the CPU is executing out of flash program memory. Although the CPU can execute out of flash data memory, it cannot erase or write the flash program memory while executing from flash data memory. To erase or write the flash program memory, the CPU must be executing from the on-chip static RAM or offchip memory. The programming mechanism is pipelined, so that a new write request can be loaded while a previous request is in progress. When the FMFULL bit in the FMSTAT or FSMSTAT register is clear, the pipeline is ready to receive a new request. New requests may be loaded after checking only the FMFULL bit. Information Block 1 contains 128 bytes, of which one 16-bit word has a dedicated function, called the Protection Word. The Protection Word resides at address 0FEh. It controls the global protection mechanisms and the size of the Boot Area. The Protection Word can be written by the CPU, however the changes only become valid after the next device reset. The remaining Information Block 1 locations can be used to store other user data. Erasing Information Block 1 also erases Main Block 1. Table 13 shows the structure of the Information Block 1. Name Main Block 2 holds the 8K-byte data area, which consists of sixteen 512-byte sections. Write access by the CPU to Main Block 2 is controlled by the corresponding bits in the FSM0WER register. The least significant bit in the register controls the section at the lowest address. An erase operation is required before programming. An erase operation sets all of the bits in the erased region. A programming operation clears selected bits. 07Eh–07Fh Other (Used for Factory Parameters) 8.2.3 Read Access Main Block 2 8.3.1 Main Block Read Read accesses from flash program memory can only occur when the flash program memory is not busy from a previous write or erase operation. Read accesses from the flash data memory can only occur when both the flash program memory and the flash data memory are not busy. Both byte and word read operations are supported. 8.3.2 Information Block Read Information block data is read through the register-based interface. Only word read operations are supported and the read address must be word-aligned (LSB = 0). The following steps are used to read from an information block: 1. Load the word address in the Flash Memory Information Block Address (FMIBAR) or Flash Slave Memory Information Block Address (FSMIBAR) register. 2. Read the data word by reading out the Flash Memory Information Block Data (FMIBDR) or Flash Slave Memory Information Block Data (FSMIBDR) register. 32 Main Block Page Erase 8.3.6 A flash erase operation sets all of the bits in the erased region. Pages of a main block can be individually erased if their write enable bits are set. This method cannot be used to erase the boot area, if defined. Each page in Main Block 0 and 1 consists of 1024 bytes (512 words). Each page in Main Block 2 consists of 512 bytes (256 words). To erase a page, the following steps are performed: Writing is only allowed when global write protection is disabled. Writing by the CPU is only allowed when the write enable bit is set for the sector which contains the word to be written. The CPU cannot write the Boot Area. Only wordwide write access to word-aligned addresses is supported. The following steps are performed to write a word: 1. Verify that the Flash Memory Busy (FMBUSY) bit in the FMSTAT or FSMSTAT register is clear. 2. Prevent accesses to the flash memory while the write is in progress. 3. Set the Program Enable (PE) bit in the FMCTRL or FSMCTRL register. 4. Write a word to the desired word-aligned address. This starts a new pipelined programming sequence. The FMBUSY bit becomes set while the write operation is in progress. The FMFULL bit in the FMSTAT or FSMSTAT register becomes set if a previous write operation is still in progress. 5. Wait until the FMFULL bit becomes clear. 6. Repeat steps 4 and 5 for additional words. 7. Wait until the FMBUSY bit becomes clear again. 8. Check the programming error (PERR) bit in the FMSTAT or FSMSTAT register to confirm successful programming. 9. Clear the Program Enable (PE) bit. 1. Verify that the Flash Memory Busy (FMBUSY) bit in the FMSTAT or FSMSTAT register is clear. 2. Prevent accesses to the flash memory while erasing is in progress. 3. Set the Page Erase (PER) bit in the FMCTRL or FSMCTRL register. 4. Write to an address within the desired page. 5. Wait until the FMBUSY bit becomes clear again. 6. Check the Erase Error (EERR) bit in the FMSTAT or FSMSTAT register to confirm successful erase of the page. 7. Repeat steps 4 through 6 to erase additional pages. 8. Clear the PER bit. 8.3.4 Main Block Write Main Block Module Erase A module erase operation can be used to erase an entire main block. All sections within the block must be enabled for writing. If a boot area is defined in the block, it cannot be erased. The following steps are performed to erase a main 8.3.7 Information Block Write block: 1. Verify that the Flash Memory Busy (FMBUSY) bit in the Writing is only allowed when global write protection is disabled. Writing by the CPU is only allowed when the write enFMSTAT or FSMSTAT register is clear. 2. Prevent accesses to the flash memory while erasing is able bit is set for the sector which contains the word to be written. The CPU cannot write Information Block 0. Only in progress. 3. Set the Module Erase (MER) bit in the FMCTRL or word-wide write access to word-aligned addresses is supported. The following steps are performed to write a word: FSMCTRL register. 4. Write to any address within the desired main block. 5. Wait until the FMBUSY bit becomes clear again. 6. Check the Erase Error (EERR) bit in the FMSTAT or FSMSTAT register to confirm successful erase of the block. 7. Clear the MER bit. 8.3.5 Information Block Module Erase Erasing an information block also erases the corresponding main block. If a boot area is defined in the main block, neither block can be erased. Page erase is not supported for information blocks. The following steps are performed to erase an information block: 1. Verify that the Flash Memory Busy (FMBUSY) bit in the FMSTAT or FSMSTAT register is clear. 2. Prevent accesses to the flash memory while erasing is in progress. 3. Set the Module Erase (MER) bit in the FMCTRL or FSMCTRL register. 4. Load the FMIBAR or FSMIBAR register with any address within the block, then write any data to the FMIBDR or FSMIBDR register. 5. Wait until the FMBUSY bit becomes clear again. 6. Check the Erase Error (EERR) bit in the FMSTAT or FSMSTAT register to confirm successful erase of the block. 7. Clear the MER bit. 1. Verify that the Flash Memory Busy (FMBUSY) bit in the FMSTAT or FSMSTAT register is clear. 2. Prevent accesses to the flash memory while the write is in progress. 3. Set the Program Enable (PE) bit in the FMCTRL or FSMCTRL register. 4. Write the desired target address into the FMIBAR or FSMIBAR register. 5. Write the data word into the FMIBDR or FSMIBDR register. This starts a new pipelined programming sequence. The FMBUSY bit becomes set while the write operation is in progress. The FMFULL bit in the FMSTAT or FSMSTAT register becomes set if a previous write operation is still in progress. 6. Wait until the FMFULL bit becomes clear. 7. Repeat steps 4 through 6 for additional words. 8. Wait until the FMBUSY bit becomes clear again. 9. Check the programming error (PERR) bit in the FMSTAT or FSMSTAT register to confirm successful programming. 10. Clear the Program Enable (PE) bit. 33 www.national.com CP3CN23 8.3.3 CP3CN23 8.4 INFORMATION BLOCK WORDS Table 14 lists all possible boot area encodings. Two words in the information blocks are dedicated to hold settings that affect the operation of the system: the Function Word in Information Block 0 and the Protection Word in Information Block 1. 8.4.1 Table 14 Boot Area Encodings Function Word The Function Word resides in the Information Block 0 at address 07Eh. At reset, the Function Word is copied into the FMAR0 register. 15 0 Reserved 8.4.2 Protection Word The Protection Word resides in Information Block 1 at address 0FEh. At reset, the Protection Word is copied into the FMAR1 register. 15 13 12 10 9 7 WRPROT RDPROT ISPE 6 4 EMPTY 3 1 0 BOOTAREA BOOTAREA The BOOTAREA field specifies the size of the Boot Area. The Boot Area starts at address 0 and ends at the address specified by this field. The inverted bits of the BOOTAREA field count the number of 2048-byte blocks to be reserved as the Boot Area. The maximum Boot Area size is 30K bytes (address range 0 to 77FFh). The end of the Boot Area defines the start of the Code Area. If the device starts in ISP mode and there is no Boot Area defined EMPTY (encoding 1111b), the device is kept in reset. ISPE www.national.com 34 BOOT AREA Size of the Boot Area Code Area Start Address 1111 No Boot Area defined 00 0000h 1110 2K bytes 00 0800h 1101 4K bytes 00 1000h 1100 6K bytes 00 1800h 1011 8K bytes 00 2000h 1010 10K bytes 00 2800h 1001 12K bytes 00 3000h 1000 14K bytes 00 3800h 0111 16K bytes 00 4000h 0110 18K bytes 00 4800h 0101 20K bytes 00 5000h 0100 22K bytes 00 5800h 0011 24K bytes 00 6000h 0010 26K bytes 00 6800h 0001 28K bytes 00 7000h 0000 30K bytes 00 7800h The EMPTY field indicates whether the flash program memory has been programmed or should be treated as blank. If a majority of the three EMPTY bits are clear, the flash program memory is treated as programmed. If a majority of the EMPTY bits are set, the flash program memory is treated as empty. If the ENV[1:0] inputs (see Section 6.1) are sampled high at reset and the EMPTY bits indicate the flash program memory is empty, the device will begin execution in ISP mode. The device enters ISP mode without regard to the EMPTY status if ENV0 is driven low and ENV1 is driven high. The ISPE field indicates whether the Boot Area is used to hold In-System-Programming routines or user application routines. If a majority of the three ISPE bits are set, the Boot Area is intended to store ISP routines. If majority of the ISPE bits are clear, the Boot Area holds user application routines. Table 15 summarizes all possible EMPTY, ISPE, and Boot Area settings and the corresponding start-up operation for each combination. In DEV mode, the EMPTY bit settings are ignored and the CPU always starts executing from address 0. EMPTY Not Empty Not Empty Not Empty ISPE Boot Area Start-Up Operation ISP Defined Device starts in IRE/ ERE mode from Code Area start address ISP Not Defined Device starts in IRE/ ERE mode from Code Area start address No ISP Device starts in IRE/ Don’t Care ERE mode from address 0 Empty ISP Defined Empty ISP Not Defined Empty No ISP Don’t Care RDPROT WRPROT 8.5 Device starts in ISP mode from Code Area start address Device starts in ISP mode and is kept in its reset state The RDPROT field controls the global read protection mechanism for the on-chip flash program memory. If a majority of the three RDPROT bits are clear, the flash program memory is protected against read access from the serial debug interface or an external flash programmer. CPU read access is not affected by the RDPROT bits. If a majority of the RDPROT bits are set, read access is allowed. The WRPROT field controls the global write protection mechanism for the on-chip flash program memory. If a majority of the three WRPROT bits are clear, the flash program memory is protected against write access from any source and read access from the serial debug interface. If a majority of the WRPROT bits are set, write access is allowed. FLASH MEMORY INTERFACE REGISTERS There is a separate interface for the program flash and data flash memories. The same set of registers exist in both interfaces. In most cases they are independent of each other, but in some cases the program flash interface controls the interface for both memories, as indicated in the following sections. Table 16 lists the registers. 35 Program Memory Data Memory Description FMIBAR FF F940h FSMIBAR FF F740h Flash Memory Information Block Address Register FMIBDR FF F942h FSMIBDR FF F742h Flash Memory Information Block Address Register FM0WER FF F944h FSM0WER FF F744h Flash Memory 0 Write Enable Register FM1WER FF F946h N/A Flash Memory 1 Write Enable Register FMCTRL FF F94Ch FSMCTRL FF F74Ch Flash Memory Control Register FMSTAT FF F94Eh FSMSTAT FF F74Eh Flash Memory Status Register FMPSR FF F950h FSMPSR FF F750h Flash Memory Prescaler Register FMSTART FF F952h FSMSTART FF F752h Flash Memory Start Time Reload Register FMTRAN FF F954h FSMTRAN FF F754h Flash Memory Transition Time Reload Register FMPROG FF F956h FSMPROG FF F756h Flash Memory Programming Time Reload Register FMPERASE FF F958h FSMPERASE FF F758h Flash Memory Page Erase Time Reload Register FMMERASE0 FF F95Ah FSMMERASE0 FF F75Ah Flash Memory Module Erase Time Reload Register 0 FMEND FF F95Eh FSMEND FF F75Eh Flash Memory End Time Reload Register FMMEND FF F960h FSMMEND FF F760h Flash Memory Module Erase End Time Reload Register FMRCV FF F962h FSMRCV FF F762h Flash Memory Recovery Time Reload Register FMAR0 FF F964h FSMAR0 FF F764h Flash Memory Auto-Read Register 0 FMAR1 FF F966h FSMAR1 FF F766h Flash Memory Auto-Read Register 1 FMAR2 FF F968h FSMAR2 FF F768h Flash Memory Auto-Read Register 2 www.national.com CP3CN23 Table 16 Flash Memory Interface Registers Table 15 CPU Reset Behavior CP3CN23 8.5.1 Flash Memory Information Block Address Register (FMIBAR/FSMIBAR) 8.5.3 The FMIBAR register specifies the 8-bit address for read or write access to an information block. Because only word access to the information blocks is supported, the least significant bit (LSB) of the FMIBAR must be 0 (word-aligned). The hardware automatically clears the LSB, without regard to the value written to the bit. The FMIBAR register is cleared after device reset. The CPU bus master has read/write access to this register. 15 8 7 Reserved 0 IBA Flash Memory 0 Write Enable Register (FM0WER/FSM0WER) The FM0WER register controls section-level write protection for the first half of the flash program memory. The FMS0WER registers controls section-level write protection for the flash data memory. Each data block is divided into 16 8K-byte sections. Each bit in the FM0WER and FSM0WER registers controls write protection for one of these sections. The FM0WER and FSM0WER registers are cleared after device reset, so the flash memory is write protected after reset. The CPU bus master has read/write access to this registers. 15 0 FM0WE IBA 8.5.2 The Information Block Address field holds the word-aligned address of an information block location accessed during a read or write FM0WEn transaction. The LSB of the IBA field is always clear. Flash Memory Information Block Data Register (FMIBDR/FSMIBDR) The FMIBDR register holds the 16-bit data for read or write access to an information block. The FMIBDR register is cleared after device reset. The CPU bus master has read/ write access to this register. 15 Bit Logical Address Range 0 00 0000h–00 1FFFh 1–14 ... 15 01 E000h–01 FFFFh 0 8.5.4 IBD IBD The Flash Memory 0 Write Enable n bits control write protection for a section of a flash memory data block. The address mapping of the register bits is shown below. The Information Block Data field holds the data word for access to an information block. For write operations the IBD field holds the data word to be programmed into the information block location specified by the IBA address. During a read operation from an information block, the IBD field receives the data word read from the location specified by the IBA address. Flash Memory 1 Write Enable Register (FM1WER) The FM1WER register controls write protection for the second half of the program flash memory. The data block is divided into 16 8K-byte sections. Each bit in the FM1WER register controls write protection for one of these sections. The FM1WER register is cleared after device reset, so the flash memory is write protected after reset. The CPU bus master has read/write access to this registers. 15 0 FM1WE FM1WEn www.national.com 36 The Flash Memory 1 Write Enable n bits control write protection for a section of a flash memory data block. The address mapping of the register bits is shown below. Bit Logical Address Range 0 02 0000h–02 1FFFh 1–14 ... 15 03 E000h–03 FFFFh Flash Data Memory 0 Write Enable Register (FSM0WER) DISVRF The FSM0WER register controls write protection for the flash data memory. The data block is divided into 16 512byte sections. Each bit in the FSM0WER register controls write protection for one of these sections. The FSM0WER register is cleared after device reset, so the flash memory is write protected after reset. The CPU bus master has read/ write access to this registers. 15 IENPROG 0 FSM0WE FSM0WEn 8.5.6 The Flash Data Memory 0 Write Enable n bits control write protection for a section of a flash PE memory data block. The address mapping of the register bits is shown below. Bit Logical Address Range 0 0D 0000h–0D 01FFh 1–14 ... 15 0D 1E00h–0D 1FFFh PER Flash Memory Control Register (FMCTRL/ FSMCTRL) This register controls the basic functions of the Flash program memory. The register is clear after device reset. The CPU bus master has read/write access to this register. 7 6 5 4 3 2 1 0 MER PER PE IENPROG DISVRF Res. CWD LOWPRW LOWPRW CWD The Low Power Mode controls whether flash program memory is operated in low-power mode, which draws less current when data is read. This is accomplished be only accessing MER the flash program memory during the first half of the clock period. The low-power mode must not be used at System Clock frequencies above 25 MHz, otherwise a read access may return undefined data. This bit must not be changed while the flash program memory is busy being programmed or erased. 0 – Normal mode. 1 – Low-power mode. The CPU Write Disable bit controls whether the CPU has write access to flash memory. This bit must not be changed while FMBUSY is set. 0 – The CPU has write access to the flash memory 1 – An external debugging tool is the current “owner” of the flash memory interface, so write accesses by the CPU are inhibited. 37 The Disable Verify bit controls the automatic verification feature. This bit must not be changed while the flash program memory is busy being programmed or erased. 0 – New flash program memory contents are automatically verified after programming. 1 – Automatic verification is disabled. The Interrupt Enable for Program bit is clear after reset. The flash program and data memories share a single interrupt channel but have independent interrupt enable control bits. 0 – No interrupt request is asserted to the ICU when the FMFULL bit is cleared. 1 – An interrupt request is made when the FMFULL bit is cleared and new data can be written into the write buffer. The Program Enable bit controls write access of the CPU to the flash program memory. This bit must not be altered while the flash program memory is busy being programmed or erased. The PER and MER bits must be clear when this bit is set. 0 – Programming the flash program memory by the CPU is disabled. 1 – Programming the flash program memory is enabled. The Page Erase Enable bit controls whether a a valid write operation triggers an erase operation on a 1024-byte page of flash memory. Page erase operations are only supported for the main blocks, not the information blocks. A page erase operation on an information block is ignored and does not alter the information block. When the PER bit is set, the PE and MER bits must be clear. This bit must not be changed while the flash program memory is busy being programmed or erased. 0 – Page erase mode disabled. Write operations are performed normally. 1 – A valid write operation to a word location in program memory erases the page that contains the word. The Module Erase Enable bit controls whether a valid write operation triggers an erase operation on an entire block of flash memory. If an information block is written in this mode, both the information block and its corresponding main block are erased. When the MER bit is set, the PE and PER bits must be clear. This bit must not be changed while the flash program memory is busy being programmed or erased. 0 – Module erase mode disabled. Write operations are performed normally. 1 – A valid write operation to a word location in a main block erases the block that contains the word. A valid write operation to a word location in an information block erases the block that contains the word and its associated main block. www.national.com CP3CN23 8.5.5 CP3CN23 8.5.7 DERR Flash Memory Status Register (FMSTAT/ FSMSTAT) The Data Loss Error bit indicates that a buffer overrun has occurred during a programming sequence. After a data loss error occurs, software can clear the DERR bit by writing a 1 to it. Writing a 0 to the DERR bit has no effect. Software must not change this bit while the flash program memory is busy being programmed or erased. 0 – No data loss error occurred. 1 – Data loss error occurred. This register reports the currents status of the on-chip Flash memory. The FLSR register is clear after device reset. The CPU bus master has read/write access to this register. 7 5 Reserved EERR PERR FMBUSY FMFULL 4 3 2 1 0 DERR FMFULL FMBUSY PERR EERR The Erase Error bit indicates whether an error has occurred during a page erase or module (block) erase. After an erase error occurs, software can clear the EERR bit by writing a 1 to it. Writing a 0 to the EERR bit has no effect. Software must not change this bit while the flash program memory is busy being programmed or erased. 0 – The erase operation was successful. 1 – An erase error occurred. The Program Error bit indicates whether an error has occurred during programming. After a programming error occurs, software can clear the PERR bit by writing a 1 to it. Writing a 0 to the PERR bit has no effect. Software must not change this bit while the flash program memory is busy being programmed or erased. 0 – The programming operation was successful. 1 – A programming error occurred. The Flash Memory Busy bit indicates whether the flash memory (either main block or information block) is busy being programmed or erased. During that time, software must not request any further flash memory operations. If such an attempt is made, the CPU is stopped as long as the FMBUSY bit is active. The CPU must not attempt to read from program memory (including instruction fetches) while it is busy. 0 – Flash memory is ready to receive a new erase or programming request. 1 – Flash memory busy with previous erase or programming operation. The Flash Memory Buffer Full bit indicates whether the write buffer for programming is full or not. When the buffer is full, new erase and write requests may not be made. The IENPROG bit can be enabled to trigger an interrupt when the buffer is ready to receive a new request. 0 – Buffer is ready to receive new erase or write requests. 1 – Buffer is full. No new erase or write requests can be accepted. www.national.com 38 8.5.8 Flash Memory Prescaler Register (FMPSR/ FSMPSR) The FMPSR register is a byte-wide read/write register that selects the prescaler divider ratio. The CPU must not modify this register while an erase or programming operation is in progress (FMBUSY is set). At reset, this register is initialized to 04h if the flash memory is idle. The CPU bus master has read/write access to this register. 7 5 4 Reserved FTDIV 8.5.9 0 FTDIV The prescaler divisor scales the frequency of the System Clock by a factor of (FTDIV + 1). Flash Memory Start Time Reload Register (FMSTART/FSMSTART) The FMSTART/FSMSTART register is a byte-wide read/ write register that controls the program/erase start delay time. Software must not modify this register while a program/erase operation is in progress (FMBUSY set). At reset, this register is initialized to 18h if the flash memory is idle. The CPU bus master has read/write access to this register. 7 0 FTSTART FTSTART The Flash Timing Start Delay Count field generates a delay of (FTSTART + 1) prescaler output clocks. Flash Memory Transition Time Reload Register (FMTRAN/FSMTRAN) 8.5.13 The FMTRAN/FMSTRAN register is a byte-wide read/write register that controls some program/erase transition times. Software must not modify this register while program/erase operation is in progress (FMBUSY set). At reset, this register is initialized to 30h if the flash memory is idle. The CPU bus master has read/write access to this register. 7 Flash Memory Module Erase Time Reload Register 0 (FMMERASE0/FSMMERASE0) The FMMERASE0/FSMMERASE0 register is a byte-wide read/write register that controls the module erase pulse width. Software must not modify this register while a program/erase operation is in progress (FMBUSY set). At reset, this register is initialized to EAh if the flash memory is idle. The CPU bus master has read/write access to this register. 0 7 FTTRAN 0 FTMER FTTRAN 8.5.11 The Flash TIming Transition Count field specifies a delay of (FTTRAN + 1) prescaler output clocks. Flash Memory Programming Time Reload Register (FMPROG/FSMPROG) 8.5.14 The FMPROG/FSMPROG register is a byte-wide read/write register that controls the programming pulse width. Software must not modify this register while a program/erase operation is in progress (FMBUSY set). At reset, this register is initialized to 16h if the flash memory is idle. The CPU bus master has read/write access to this register. 7 FTMER 0 The Flash Timing Module Erase Pulse Width field specifies a module erase pulse width of 4096 × (FTMER + 1) prescaler output clocks. Flash Memory End Time Reload Register (FMEND/FSMEND) The FMEND/FSMEND register is a byte-wide read/write register that controls the delay time after a program/erase operation. Software must not modify this register while a program/erase operation is in progress (FMBUSY set). At reset, this register is initialized to 18h when the flash memory on the chip is idle. The CPU bus master has read/write access to this register. FTPROG 7 0 FTEND FTPROG 8.5.12 The Flash Timing Programming Pulse Width field specifies a programming pulse width of 8 × (FTPROG + 1) prescaler output clocks. FTEND The Flash Timing End Delay Count field specifies a delay of (FTEND + 1) prescaler output clocks. Flash Memory Page Erase Time Reload Register (FMPERASE/FSMPERASE) The FMPERASE/FSMPERASE register is a byte-wide read/write register that controls the page erase pulse width. Software must not modify this register while a program/ erase operation is in progress (FMBUSY set). At reset, this register is initialized to 04h if the flash memory is idle. The CPU bus master has read/write access to this register. 7 0 8.5.15 Flash Memory Module Erase End Time Reload Register (FMMEND/FSMMEND) The FMMEND/FSMMEND register is a byte-wide read/write register that controls the delay time after a module erase operation. Software must not modify this register while a program/erase operation is in progress (FMBUSY set). At reset, this register is initialized to 3Ch if the flash memory is idle. The CPU bus master has read/write access to this register. FTPER 7 FTPER 0 FTMEND The Flash Timing Page Erase Pulse Width field specifies a page erase pulse width of 4096 × (FTPER + 1) prescaler output clocks. FTMEND 39 The Flash Timing Module Erase End Delay Count field specifies a delay of 8 × (FTMEND + 1) prescaler output clocks. www.national.com CP3CN23 8.5.10 CP3CN23 8.5.16 Flash Memory Recovery Time Reload Register (FMRCV/FSMRCV) 8.5.18 The FMRCV/FSMRCV register is a byte-wide read/write register that controls the recovery delay time between two flash memory accesses. Software must not modify this register while a program/erase operation is in progress (FMBUSY set). At reset, this register is initialized to 04h if the flash memory is idle. The CPU bus master has read/write access to this register. 7 Flash Memory Auto-Read Register 1 (FMAR1/ FSMAR1) The FMAR1 register contains a copy of the Protection Word from Information Block 1. The Protection Word is sampled at reset. The contents of the FMAR1 register define the current Flash memory protection settings. The CPU bus master has read-only access to this register. The FSMAR1 register has the same value as the FMAR1 register. The format is the same as the format of the Protection Word (see Section 8.4.2). 0 15 FTRCV 13 12 10 9 7 6 4 3 1 0 WRPROT RDPROT ISPE EMPTY BOOTAREA 1 FTRCV 8.5.17 The Flash Timing Recovery Delay Count field specifies a delay of (FTRCV + 1) prescaler output clocks. 8.5.19 Flash Memory Auto-Read Register 2 (FMAR2/ FSMAR2) The FMAR2 register is a word-wide read-only register, which is loaded during reset. It is used to build the Code Area start address. At reset, the CPU executes a branch, using the contents of the FMAR2 register as displacement. The CPU bus master has read-only access to this register. Flash Memory Auto-Read Register 0 (FMAR0/ FSMAR0) The FMAR0/FSMAR0 register contains a copy of the Function Word from Information Block 0. The Function Word is sampled at reset. The CPU bus master has read-only access to this register. The FSMAR0 register has the same The FSMAR2 register has the same value as the FMAR2 register. value as the FMAR0 register 15 7 0 0 CADR7:0 Reserved 15 CADR15 CADR10:0 14 11 CADR14:11 10 8 CADR10:8 The Code Area Start Address (bits 10:0) contains the lower 11 bits of the Code Area start address. The CADR10:0 field has a fixed value of 0. CADR14:11 The Code Area Start Address (bits 14:11) are loaded during reset with the inverted value of BOOTAREA3:0. CADR15 The Code Area Start Address (bits 15) contains the upper bit of the Code Area start address. The CADR15 field has a fixed value of 0. www.national.com 40 DMA Controller The DMA Controller (DMAC) has a register-based programming interface, as opposed to an interface based on I/O control blocks. After loading the registers with source and destination addresses, as well as block size and type of operation, a DMAC channel is ready to respond to DMA transfer requests. A request can only come from on-chip peripherals or software, not external peripherals. On receiving a DMA transfer request, if the channel is enabled, the DMAC performs the following operations: 1. Arbitrates to become master of the CPU bus. 2. Determines priority among the DMAC channels, one clock cycle before T1 of the DMAC transfer cycle. (T1 is the first clock cycle of the bus cycle.) Priority among the DMAC channels is fixed in descending order, with Channel 0 having the highest priority. 3. Executes data transfer bus cycle(s) selected by the values held in the control registers of the channel being serviced, and according to the accessed memory address. The DMAC acknowledges the request during the bus cycle that accesses the requesting device. 4. If the transfer of a block is terminated, the DMAC does the following: Updates the termination bits. Generates an interrupt (if enabled). Goes to step 6. 5. If DMRQn is still active, and the Bus Policy is “continuous”, returns to step 3. 6. Returns mastership of the CPU bus to the CPU. Each DMAC channel can be programmed for direct (flyby) or indirect (memory-to-memory) data transfers. Once a DMAC transfer cycle is in progress, the next transfer request is sampled when the DMAC acknowledge is de-asserted, then on the rising edge of every clock cycle. The configuration of either address freeze or address update (increment or decrement) is independent of the number of transferred bytes, transfer direction, or number of bytes in each DMAC transfer cycle. All these can be configured for each channel by programming the appropriate control registers. Table 17 DMA Channel Assignment Channel Peripheral Transaction Register 0 (Primary) Reserved N/A N/A 0 (Secondary) USART R RXBUF 1 (Primary) USART W TXBUF 1 (Secondary) Reserved N/A N/A 2 (Primary) Audio Interface R ARDR0 2 (Secondary) CVSD/PCM Transcoder R PCMOUT 3 (Primary) Audio Interface W ATDR0 3 (Secondary) CVSD/PCM Transcoder W PCMIN 9.2 TRANSFER TYPES The DMAC uses two data transfer modes, Direct (Flyby) and Indirect (Memory-to-Memory). The choice of mode depends on the required bus performance and whether direct mode is available for the transfer. Indirect mode must be used when the source and destination have differing bus widths, when both the source and destination are in memory, and when the destination does not support direct mode. 9.2.1 Direct (Flyby) Transfers In direct mode each data item is transferred using a single bus cycle, without reading the data into the DMAC. It provides the fastest transfer rate, but it requires identical source and destination bus widths. The DMAC cannot use Direct cycles between two memory devices. One of the devices must be an I/O device that supports the Direct (Flyby) mechanism, as shown in Figure 3. Bus State T1 Each DMAC channel has eight control registers. DMAC channels are described hereafter with the suffix n, where n = 0 to 3, representing the channel number in the registernames. 9.1 CP3CN23 9.0 Tidle T1 CLK DMRQ[3:0] CHANNEL ASSIGNMENT ADDR Table 17 shows the assignment of the DMA channels to different tasks. Four channels can be shared by a primary and an secondary function. However, only one source at a time can be enabled. If a channel is used for memory block transfers, other resources must be disabled. T2 ADCA DMACK[3:0] DS005 Figure 3. Direct DMA Cycle Followed by a CPU Cycle 41 www.national.com CP3CN23 Direct mode supports two bus policies: intermittent and continuous. In intermittent mode, the DMAC gives bus mastership back to the CPU after every cycle. In continuous mode, the DMAC remains bus master until the transfer is completed. The maximum bus throughput in intermittent mode is one transfer for every three System Clock cycles. The maximum bus throughput in continuous mode is one transfer for every clock cycle. The I/O device which made the DMA request is called the implied I/O device. The other device can be either memory or another I/O device, and is called the addressed device. Because only one address is required in direct mode, this address is taken from the corresponding ADCAn counter. The DMAC channel generates either a read or a write bus cycle, as controlled by the DMACNTLn.DIR bit. When the DMACNTLn.DIR bit is clear, a read bus cycle from the addressed device is performed, and the data is written to the implied I/O device. When the DMACNTLn.DIR bit is set, a write bus cycle to the addressed device is performed, and the data is read from the implied I/O device. The configuration of either address freeze or address update (increment or decrement) is independent of the number of transferred bytes, transfer direction, or number of bytes in each DMAC transfer cycle. All these can be configured for each channel by programming the appropriate control register. Whether 8 or 16 bits are transferred in each cycle is selected by the DMACNTLn.TCS register bit. After the data item has been transferred, the BLTCn counter is decremented by one. The ADCAn counter is updated according to the INCA and ADA fields in the DMACNTLn register. 9.2.2 Indirect (Memory-To-Memory) Transfers In indirect (memory-to-memory) mode, data transfers use two consecutive bus cycles. The data is first read into a temporary register, and then written to the destination in the following cycle. This mode is slower than the direct (flyby) mode, but it provides support for different source and destination bus widths. Indirect mode must be used for transfers between memory devices. If an intermittent bus policy is used, the maximum throughput is one transfer for every five clock cycles. If a continuous bus policy is used, maximum throughput is one transfer for every two clock cycles. 9.3 OPERATION MODES The DMAC operates in three different block transfer modes: single transfer, double buffer, and auto-initialize. 9.3.1 Single Transfer Operation This mode provides the simplest way to accomplish a single block data transfer. Initialization 1. Write the block transfer addresses and byte count into the corresponding ADCAn, ADCBn, and BLTCn counters. 2. Clear the DMACNTLn.OT bit to select non-auto-initialize mode. Clear the DMASTAT.VLD bit by writing a 1 to it. 3. Set the DMACNTLn.CHEN bit to activate the channel and enable it to respond to DMA transfer requests. Termination When the BLTCn counter reaches 0: 1. The transfer operation terminates. 2. The DMASTAT.TC and DMASTAT.OVR bits are set, and the DMASTAT.CHAC bit is cleared. 3. An interrupt is generated if enabled by the DMACNTLn.ETC or DMACNTLn.EOVR bits. The DMACNTLn.CHEN bit must be cleared before loading the DMACNTLn register to avoid prematurely starting a new DMA transfer. 9.3.2 Double Buffer Operation This mode allows software to set up the next block transfer while the current block transfer proceeds. Initialization 1. Write the block transfer addresses and byte count into the ADCAn, ADCBn, and BLTCn counters. 2. Clear the DMACNTLn.OT bit to select non-auto-initialize mode. Clear the DMASTAT.VLD bit by writing a 1 to it. 3. Set the DMACNTLn.CHEN bit. This activates the channel and enables it to respond to DMA transfer requests. 4. While the current block transfer proceeds, write the addresses and byte count for the next block into the ADRAn, ADRBn, and BLTRn registers. The BLTRn register must be written last, because it sets the DMASTAT.VLD bit which indicates that all the parameters for the next transfer have been updated. When the DMACNTLn.DIR bit is 0, the first bus cycle reads data from the source using the ADCAn counter, while the Continuation/Termination second bus cycle writes the data into the destination using When the BLTCn counter reaches 0: the ADCBn counter. When the DMACNTLn.DIR bit is set, the first bus cycle reads data from the source using the AD- 1. The DMASTAT.TC bit is set. CBn counter, while the second bus cycle writes the data into 2. An interrupt is generated if enabled by the DMACNTLn.ETC bit. the destination addressed by the ADCAn counter. 3. The DMAC channel checks the value of the VLD bit. The number of bytes transferred in each cycle is taken from the DMACNTLn.TCS register bit. After the data item has If the DMASTAT.VLD bit is set: been transferred, the BLTCn counter is decremented by 1. The channel copies the ADRAn, ADRBn, and BLTRn one. The ADCAn and ADCBn counters are updated accordvalues into the ADCAn, ADCBn, and BLTCn registers. ing to the INCA, INCB, ADA, and ADB fields in the 2. The DMASTAT.VLD bit is cleared. DMACNTLn register. 3. The next block transfer is started. www.national.com 42 1. 2. 3. 4. The transfer operation terminates. The channel sets the DMASTAT.OVR bit. The DMASTAT.CHAC bit is cleared. An interrupt is generated if enabled DMACNTLn.EOVR bit. by the The DMACNTLn.CHEN bit must be cleared before loading the DMACNTLn register to avoid prematurely starting a new DMA transfer. For each channel, use the software DMA transfer request only when the corresponding hardware DMA request is inactive and no terminal count interrupt is pending. Software can poll the DMASTAT.CHAC bit to determine whether the DMA channel is already active. After verifying the DMASTATn.CHAC bit is clear (channel inactive), check the DMASTATn.TC (terminal count) bit. If the TC bit is clear, then no terminal count condition exists and therefore no terminal count interrupt is pending. If the channel is not active and no terminal count interrupt is pending, software may request a DMA transfer. Note: The ADCBn and ADRBn registers are used only in indirect (memory-to-memory) transfer. In direct (flyby) 9.5 DEBUG MODE mode, the DMAC does not use them and therefore does not When the FREEZE signal is active, all DMA operations are copy ADRBn into ADCBn. stopped. They will start again when the FREEZE signal 9.3.3 Auto-Initialize Operation goes inactive. This allows breakpoints to be used in debug This mode allows the DMAC to continuously fill the same systems. memory area without software intervention. 9.6 DMA CONTROLLER REGISTER SET Initialization There are four identical sets of DMA controller registers, as 1. Write the block addresses and byte count into the ADlisted in Table 18. CAn, ADCBn, and BLTCn counters, as well as the Table 18 DMA Controller Registers ADRAn, ADRBn, and BLTRn registers. 2. Set the DMACNTLn.OT bit to select auto-initialize Name Address Description mode. 3. Set the DMACNTLn.CHEN bit to activate the channel Device A Address and enable it to respond to DMA transfer requests. ADCA0 FF F800h Counter Register Continuation Device A Address ADRA0 FF F804h When the BLTCn counter reaches 0: Register 1. The contents of the ADRAn, ADRBn, and BLTRn regisDevice B Address ters are copied to the ADCAn, ADCBn, and BLTCn ADCB0 FF F808h Counter Register counters. 2. The DMAC channel checks the value of the DMASDevice B Address ADRB0 FF F80Ch TAT.TC bit. Register If the DMASTAT.TC bit is set: Block Length BLTC0 FF F810h 1. The DMASTAT.OVR bit is set. Counter Register 2. A level interrupt is generated if enabled by the BLTR0 FF F814h Block Length Register DMACNTLn.EOVR bit. 3. The operation is repeated. DMACNTL0 FF F81Ch DMA Control Register If the DMASTAT.TC bit is clear: DMASTAT0 FF F81Eh DMA Status Register 1. The DMASTAT.TC bit is set. 2. A level interrupt is generated if enabled by the Device A Address ADCA1 FF F820h DMACNTLn.ETC bit. Counter Register 3. The DMAC operation is repeated. Device A Address ADRA1 FF F824h Termination Register The DMA transfer is terminated when the Device B Address ADCB1 FF F828h DMACNTLn.CHEN bit is cleared. Counter Register 9.4 SOFTWARE DMA REQUEST In addition to the hardware requests from I/O devices, a DMA transfer request can also be initiated by software. A software DMA transfer request must be used for block copying between memory devices. ADRB1 FF F82Ch Device B Address Register BLTC1 FF F830h Block Length Counter Register When the DMACNTLn.SWRQ bit is set, the corresponding DMA channel receives a DMA transfer request. When the DMACNTLn.SWRQ bit is clear, the software DMA transfer request of the corresponding channel is inactive. BLTR1 FF F834h Block Length Register DMACNTL1 FF F83Ch DMA Control Register DMASTAT1 FF F83Eh DMA Status Register 43 www.national.com CP3CN23 If the DMASTAT.VLD bit is clear: CP3CN23 9.6.2 Table 18 DMA Controller Registers Name Address Description ADCA2 FF F840h Device A Address Counter Register ADRA2 FF F844h Device A Address Register ADCB2 FF F848h Device B Address Counter Register ADRB2 FF F84Ch Device B Address Register Device A Address Register (ADRAn) The Device A Address register is a 32-bit, read/write register. It holds the 24-bit starting address of either the next source data block, or the next destination data area, according to the DIR bit in the DMACNTLn register. The upper 8 bits of the ADRAn register are reserved and always clear. 31 24 9.6.3 Device B Address Counter Register (ADCBn) FF F850h Block Length Counter Register BLTR2 FF F854h Block Length Register DMACNTL2 FF F85Ch DMA Control Register DMASTAT2 FF F85Eh DMA Status Register ADCA3 FF F860h Device A Address Counter Register ADRA3 FF F864h Device A Address Register ADCB3 FF F868h Device B Address Counter Register ADRB3 FF F86Ch Device B Address Register BLTC3 FF F870h Block Length Counter Register BLTR3 FF F874h Block Length Register DMACNTL3 FF F87Ch DMA Control Register 31 DMASTAT3 FF F87Eh DMA Status Register Reserved 31 24 23 Reserved 9.6.4 0 Device B Address Counter Device B Address Register (ADRBn) The Device B Address register is a 32-bit, read/write register. It holds the 24-bit starting address of either the next source data block or the next destination data area, according to the DIR bit in the CNTLn register. In direct (flyby) mode, this register is not used. The upper 8 bits of the ADCRBn register are reserved and always clear. 24 23 0 Device B Address Device A Address Counter Register (ADCAn) The Device A Address Counter register is a 32-bit, read/ write register. It holds the current 24-bit address of either the source data item or the destination location, depending on the state of the DIR bit in the CNTLn register. The ADA bit of DMACNTLn register controls whether to adjust the pointer in the ADCAn register by the step size specified in the INCA field of DMACNTLn register. The upper 8 bits of the ADCAn register are reserved and always clear. 31 0 Device A Address The Device B Address Counter register is a 32-bit, read/ write register. It holds the current 24-bit address of either the source data item, or the destination location, according to the DIR bit in the CNTLn register. The ADCBn register is updated after each transfer cycle by INCB field of the DMACNTLn register according to ADB bit of the DMACNTLn register. In direct (flyby) mode, this register is not used. The upper 8 bits of the ADCBn register are reserved and always clear. BLTC2 9.6.1 23 Reserved 24 Reserved 23 9.6.5 Block Length Counter Register (BLTCn) The Block Length Counter register is a 16-bit, read/write register. It holds the current number of DMA transfers to be executed in the current block. BLTCn is decremented by one after each transfer cycle. A DMA transfer may consist of 1 or 2 bytes, as selected by the DMACNTLn.TCS bit. 15 0 Block Length Counter 0 Device A Address Counter Note: 0000h is interpreted as 216-1 transfer cycles. www.national.com 44 Block Length Register (BLTRn) DIR The Block Length register is a 16-bit, read/write register. It holds the number of DMA transfers to be performed for the next block. Writing this register automatically sets the DMASTAT.VLD bit. 15 0 OT Block Length Note: 0000h is interpreted as 216-1 transfer cycles. 9.6.7 DMA Control Register (DMACNTLn) BPC The DMA Control register n is a word-wide, read/write register that controls the operation of DMA channel n. This register is cleared at reset. Reserved bits must be written with 0. 7 6 5 4 BPC OT DIR IND TCS EOVR ETC CHEN 15 14 13 12 11 Res. CHEN ETC EOVR TCS IND INCB ADB 3 2 10 INCA 1 9 0 8 ADA SWRQ SWRQ The Channel Enable bit must be set to enable any DMA operation on this channel. Writing a 1 to this bit starts a new DMA transfer even if it is currently a 1. If all DMACNTLn.CHEN bits are clear, the DMA clock is disabled to reduce power. 0 – Channel disabled. 1 – Channel enabled. If the Enable Interrupt on Terminal Count bit is set, it enables an interrupt when the DMASTAT.TC bit is set. 0 – Interrupt disabled. 1 – Interrupt enabled. If the Enable Interrupt on OVR bit is set, it enables an interrupt when the DMASTAT.OVR bit is set. 0 – Interrupt disabled. 1 – Interrupt enabled. The Transfer Cycle Size bit specifies the number of bytes transferred in each DMA transfer cycle. In direct (fly-by) mode, undefined results occur if the TCS bit is not equal to the addressed memory bus width. 0 – Byte transfers (8 bits per cycle). 1 – Word transfers (16 bits per cycle). The Direct/Indirect Transfer bit specifies the transfer type. 0 – Direct transfer (flyby). 1 – Indirect transfer (memory-to-memory). ADA INCA ADB INCB 45 The Transfer Direction bit specifies the direction of the transfer relative to Device A. 0 – Device A (pointed to by the ADCAn register) is the source. In Fly-By mode a read transaction is initialized. 1 – Device A (pointed to by the ADCAn register) is the destination. In Fly-By mode a write transaction is initialized. The Operation Type bit specifies the operation mode of the DMA controller. 0 – Single-buffer mode or double-buffer mode enabled. 1 – Auto-Initialize mode enabled. The Bus Policy Control bit specifies the bus policy applied by the DMA controller. The operation mode can be either intermittent (cycle stealing) or continuous (burst). 0 – Intermittent operation. The DMAC channel relinquishes the bus after each transaction, even if the request is still asserted. 1 – Continuous operation. The DMAC channel n uses the bus continuously as long as the request is asserted. This mode can only be used for software DMA requests. For hardware DMA requests, the BPC bit must be clear. The Software DMA Request bit is written with a 1 to initiate a software DMA request. Writing a 0 to this bit deactivates the software DMA request. The SWRQ bit must only be written when the DMRQ signal for this channel is inactive (DMASTAT.CHAC = 0). 0 – Software DMA request is inactive. 1 – Software DMA request is active. If the Device A Address Control bit is set, it enables updating the Device A address. 0 – ADCAn address unchanged. 1 – ADCAn address incremented or decremented, according to INCA field of DMACNTLn register. The Increment/Decrement ADCAn field specifies the step size for the Device A address increment/decrement. 00 – Increment ADCAn register by 1. 01 – Increment ADCAn register by 2. 10 – Decrement ADCAn register by 1. 11 – Decrement ADCAn register by 2. If the Device B Address Control bit is set, it enables updating the Device B Address. 0 – ADCBn address unchanged. 1 – ADCBn address incremented or decremented, according to INCB field of DMACNTLn register. The Increment/Decrement ADCBn field specifies the step size for the Device B address increment/decrement. 00 – Increment ADCBn register by 1. 01 – Increment ADCBn register by 2. 10 – Decrement ADCBn register by 1. 11 – Decrement ADCBn register by 2. www.national.com CP3CN23 9.6.6 CP3CN23 9.6.8 DMA Status Register (DMASTAT) The DMA status register is a byte-wide, read register that holds the status information for the DMA channel n. This register is cleared at reset. The reserved bits always return zero when read. The VLD, OVR and TC bits are sticky (once set by the occurrence of the specific condition, they remain set until explicitly cleared by software). These bits can be individually cleared by writing 1 to the bit positions in the DMASTAT register to be cleared. Writing 0 to these bits has no effect 7 4 Reserved TC OVR CHAC VLD 3 2 1 VLD CHAC OVR 0 TC The Terminal Count bit indicates whether the transfer was completed by a terminal count condition (BLTCn Register reached 0). 0 – Terminal count condition did not occur. 1 – Terminal count condition occurred. The behavior of the Channel Overrun bit depends on the operation mode (single buffer, double buffer, or auto-initialize) of the DMA channel. In double-buffered mode (DMACNTLn.OT = 0): The OVR bit is set when the present transfer is completed (BLTCn = 0), but the parameters for the next transfer (address and block length) are not valid (DMASTAT.VLD = 0). In auto-initialize mode (DMACNTLn.OT = 1): The OVR bit is set when the present transfer is completed (BLTCn = 0), and the DMASTAT.TC bit is still set. In single-buffer mode: Operates in the same way as double-buffer mode. In single-buffered mode, the DMASTAT.VLD bit should always be clear, so it will also be set when the DMASTAT.TC bit is set. Therefore, the OVR bit can be ignored in this mode. The Channel Active bit continuously indicates the active or inactive status of the channel, and therefore, it is read only. Data written to the CHAC bit is ignored. 0 – Channel inactive. 1 – Indicates that the channel is active (CHEN bit in the CNTLn register is 1 and BLTCn > 0) The Transfer Parameters Valid bit specifies whether the transfer parameters for the next block to be transferred are valid. Writing the BLTRn register automatically sets this bit. The bit is cleared in the following cases: The present transfer is completed and the ADRAn, ADRBn (indirect mode only), and BLTR registers are copied to the ADCAn, ADCBn (indirect mode only), and BLTCn registers. Writing 1 to the VLD bit. www.national.com 46 The Interrupt Control Unit (ICU) receives interrupt requests from internal and external sources and generates interrupts to the CPU. Interrupts from the timers, UARTs, Microwire/ SPI interface, and Multi-Input Wake-Up module are all maskable interrupts. The highest-priority interrupt is the Non-Maskable Interrupt (NMI), which is triggered by a falling edge received on the NMI input pin. 10.2.1 10.1 would seem that the interrupt vector would never return the value 10h. If it does return a value of 10h, the entry in the dispatch table should point to a default interrupt handler that handles this error condition. One possible condition for this to occur is deassertion of the interrupt before the interrupt acknowledge cycle. Maskable Interrupt Processing Interrupt vector numbers are always positive, in the range 10h to 3Fh. The IVCT register contains the interrupt vector of the enabled and pending interrupt with the highest priority. The interrupt vector 10h corresponds to IRQ0 and the lowest priority, while the vector 3Fh corresponds to IRQ47 and the highest priority. The CPU performs an interrupt acThe priorities of the maskable interrupts are hardwired and knowledge bus cycle on receiving a maskable interrupt retherefore fixed. The implemented interrupts are named quest from the ICU. During the interrupt acknowledge cycle, IRQ0 through IRQ47, in which IRQ0 has the lowest priority a byte is read from address FF FE00h (IVCT register). The and IRQ47 has the highest priority. (IRQ0 is not implement- byte is used as an index into the Dispatch Table to detered, so IRQ1 is the lowest priority interrupt that normally may mine the address of the interrupt handler. occur.) Because IRQ0 is not connected to any interrupt source, it NON-MASKABLE INTERRUPTS The Interrupt Control Unit (ICU) receives the external NMI input and generates the NMI signal driven to the CPU. The NMI input is an asynchronous input with Schmitt trigger characteristics and an internal synchronization circuit, therefore no external synchronizing circuit is needed. The NMI pin triggers an exception on its falling edge. 10.1.1 10.3 INTERRUPT CONTROLLER REGISTERS Table 19 lists the ICU registers. Non-Maskable Interrupt Processing The CPU performs an interrupt acknowledge bus cycle when beginning to process a non-maskable interrupt. Table 19 Interrupt Controller Registers Name Address Description IVCT FF FE00h Interrupt Vector Register NMISTAT FF FE02h Non-Maskable Interrupt Status Register EXNMI FF FE04h External NMI Trap Control and Status Register ISTAT0 FF FE0Ah Interrupt Status Register 0 The maskable interrupts are globally enabled and disabled by the E bit in the PSR register. The EI and DI instructions are used to set (enable) and clear (disable) this bit. The global maskable interrupt enable bit (I bit in the PSR) must also be set before any maskable interrupts are taken. ISTAT1 FF FE0Ch Interrupt Status Register 1 ISTAT2 FF FE20h Interrupt Status Register 2 Each interrupt source can be individually enabled or disabled under software control through the ICU interrupt enable registers and also through interrupt enable bits in the peripherals that request the interrupts. The ICU supports IRQ0, but in the CP3CN23 it is not connected to any interrupt source. IENAM0 FF FE0Eh Interrupt Enable and Mask Register 0 IENAM1 FF FE10h Interrupt Enable and Mask Register 1 IENAM2 FF FE22h Interrupt Enable and Mask Register 2 At reset, NMI interrupts are disabled and must remain disabled until software initializes the interrupt table, interrupt base register (INTBASE), and the interrupt mode. The external NMI interrupt is enabled by setting the EXNMI.ENLCK bit and will remain enabled until a reset occurs. Alternatively, the external NMI interrupt can be enabled by setting the EXNMI.EN bit and will remain enabled until an interrupt event or a reset occurs. 10.2 MASKABLE INTERRUPTS The ICU receives level-triggered interrupt request signals from 47 sources and generates a vectored interrupt to the CPU when required. Priority among the implemented interrupt sources (named IRQ1 through IRQ47) is fixed. 47 www.national.com CP3CN23 10.0 Interrupts CP3CN23 10.3.1 Interrupt Vector Register (IVCT) 10.3.3 The IVCT register is a byte-wide read-only register which reports the encoded value of the highest priority maskable interrupt that is both asserted and enabled. The valid range is from 10h to 3Fh. The register is read by the CPU during an interrupt acknowledge bus cycle, and INTVECT is valid during that time. It may contain invalid data while INTVECT is updated. 7 6 0 0 INTVECT 10.3.2 5 0 The EXNMI register is a byte-wide read/write register. It indicates the current value of the NMI pin and controls the NMI interrupt trap generation based on a falling edge of the NMI pin. TST, EN and ENLCK are cleared on reset. When writing to this register, all reserved bits must be written with 0 for the device to function properly 7 INTVECT EN Non-Maskable Interrupt Status Register (NMISTAT) The NMISTAT register is a byte-wide read-only register. It holds the status of the current pending Non-Maskable Interrupt (NMI) requests. On the CP3CN23, the external NMI input is the only source of NMI interrupts. The NMISTAT register is cleared on reset and each time its contents are read. 1 Reserved EXT 0 EXT The External NMI request bit indicates whether an external non-maskable interrupt request has occurred. Refer to the description of the EXNMI register below for additional details. 0 – No external NMI request. 1 – External NMI request has occurred. www.national.com 3 Reserved The Interrupt Vector field indicates the highest priority interrupt which is both asserted and enabled. 7 External NMI Trap Control and Status Register (EXNMI) 48 PIN ENLCK 2 1 0 ENLCK PIN EN The EXNMI trap enable bit is one of two bits that can be used to enable NMI interrupts. The bit is cleared by hardware at reset and whenever the NMI interrupt occurs (EXNMI.EXT set). It is intended for applications where the NMI input toggles frequently but nested NMI traps are not desired. For these applications, the EN bit needs to be re-enabled before exiting the trap handler. When used this way, the ENLCK bit should never be set. The EN bit can be set and cleared by software (software can set this bit only if EXNMI.EXT is cleared), and should only be set after the interrupt base register and the interrupt stack pointer have been set up. 0 – NMI interrupts not enabled by this bit (but may be enabled by the ENLCK bit). 1 – NMI interrupts enabled. The PIN bit indicates the state (non-inverted) on the NMI input pin. This bit is read-only, data written into it is ignored. 0 – NMI pin not asserted. 1 – NMI pin asserted. The EXNMI trap enable lock bit is used to permanently enable NMI interrupts. Only a device reset can clear the ENLCK bit. This allows the external NMI feature to be enabled after the interrupt base register and the interrupt stack pointer have been set up. When the ENLCK bit is set, the EN bit is ignored. 0 – NMI interrupts not enabled by this bit (but may be enabled by the EN bit). 1 – NMI interrupts enabled. Interrupt Enable and Mask Register 0 (IENAM0) The IENAM0 register is a word-wide read/write register which holds bits that individually enable and disable the maskable interrupt sources IRQ1 through IRQ15. The register is initialized to FFFFh at reset. 15 1 IENA IENA 10.3.5 15 Res. Interrupt Enable and Mask Register 1 (IENAM1) IST 10.3.8 The Interrupt Status bits indicate if a maskable interrupt source is signalling an interrupt request. IST15:1 correspond to IRQ15 to IRQ1 respectively. Because the IRQ0 interrupt is not used, bit 0 always reads back 0. 0 – Interrupt is not active. 1 – Interrupt is active. Interrupt Status Register 1 (ISTAT1) 0 IST Each Interrupt Enable bit enables or disables the corresponding interrupt request IRQ16 through IRQ31, for example IENA31 controls IRQ31. 0 – Interrupt is disabled. 1 – Interrupt is enabled. Interrupt Enable and Mask Register 2 (IENAM2) The IENAM2 register is a word-wide read/write register which holds bits that individually enable and disable the maskable interrupt sources IRQ32 through IRQ47. The register is initialized to FFFFh at reset. IST 10.3.9 The Interrupt Status bits indicate if a maskable interrupt source is signalling an interrupt request. IST31:16 correspond to IRQ31 to IRQ16, respectively. 0 – Interrupt is not active. 1 – Interrupt is active. Interrupt Status Register 2 (ISTAT2) The ISTAT2 register is a word-wide read-only register. It indicates which maskable interrupt inputs into the ICU are active. These bits are not affected by the state of the corresponding IENA bits. 0 15 IENA IENA Res. 15 0 15 0 The ISTAT1 register is a word-wide read-only register. It indicates which maskable interrupt inputs into the ICU are active. These bits are not affected by the state of the corresponding IENA bits. IENA 10.3.6 1 IST The IENAM1 register is a word-wide read/write register which holds bits that individually enable and disable the maskable interrupt sources IRQ16 through IRQ31. The register is initialized to FFFFh at reset. IENA Interrupt Status Register 0 (ISTAT0) The ISTAT0 register is a word-wide read-only register. It indicates which maskable interrupt inputs to the ICU are active. These bits are not affected by the state of the corresponding IENA bits. 0 Each Interrupt Enable bit enables or disables the corresponding interrupt request IRQ1 through IRQ15, for example IENA15 controls IRQ15. Because IRQ0 is not used, IENA0 is ignored. 0 – Interrupt is disabled. 1 – Interrupt is enabled. 15 10.3.7 0 IST Each Interrupt Enable bit enables or disables the corresponding interrupt request IRQ32 through IRQ47, for example IENA47 controls IRQ47. 0 – Interrupt is disabled. 1 – Interrupt is enabled. IST 49 The Interrupt Status bits indicate if a maskable interrupt source is signalling an interrupt request. IST47:32 correspond to IRQ47 to IRQ32, respectively. 0 – Interrupt is not active. 1 – Interrupt is active. www.national.com CP3CN23 10.3.4 CP3CN23 10.4 MASKABLE INTERRUPT SOURCES Table 20 shows the interrupts assigned to various on-chip maskable interrupts. The priority of simultaneous maskable interrupts is linear, with IRQ47 having the highest priority. IRQ Number Table 20 Maskable Interrupts Assignment IRQ Number Description IRQ47 TWM (Timer 0) IRQ46 Reserved IRQ45 Reserved IRQ44 Reserved IRQ43 Reserved IRQ42 Reserved IRQ41 Reserved IRQ40 Reserved IRQ39 DMA Channel 0 IRQ38 DMA Channel 1 IRQ37 DMA Channel 2 IRQ36 DMA Channel 3 IRQ35 CAN0 IRQ34 Advanced Audio Interface (AAI) IRQ33 UART0 RX IRQ32 CVSD/PCM Converter IRQ31 ACCESS.bus IRQ30 TA (Timer input A) IRQ29 TB (Timer input B) IRQ28 VTUA (VTU Interrupt Request 1) IRQ27 VTUB (VTU Interrupt Request 2) IRQ26 VTUC (VTU Interrupt Request 3) IRQ25 VTUD (VTU Interrupt Request 4) IRQ24 Microwire/SPI RX/TX IRQ23 UART0 TX IRQ22 UART0 CTS IRQ21 CAN1 IRQ20 UART1 RX IRQ19 UART1 TX IRQ18 UART2 RX IRQ17 UART2 TX IRQ16 UART3 RX IRQ15 UART3 TX www.national.com Description IRQ14 Reserved IRQ13 ADC (Done) IRQ12 MIWU Interrupt 0 IRQ11 MIWU Interrupt 1 IRQ10 MIWU Interrupt 2 IRQ9 MIWU Interrupt 3 IRQ8 MIWU Interrupt 4 IRQ7 MIWU Interrupt 5 IRQ6 MIWU Interrupt 6 IRQ5 MIWU Interrupt 7 IRQ4 Reserved IRQ3 Random Number Generator (RNG) IRQ2 Reserved IRQ1 Flash Program/Data Memory IRQ0 Reserved All reserved interrupt vectors should point to default or error interrupt handlers. 10.5 NESTED INTERRUPTS Nested NMI interrupts are always enabled. Nested maskable interrupts are disabled by default, however an interrupt handler can allow nested maskable interrupts by setting the I bit in the PSR. The LPR instruction is used to set the I bit. Nesting of specific maskable interrupts can be allowed by disabling interrupts from sources for which nesting is not allowed, before setting the I bit. Individual maskable interrupt sources can be disabled using the IENAM0 and IENAM1 registers. Any number of levels of nested interrupts are allowed, limited only by the available memory for the interrupt stack. 50 The Triple Clock and Reset module generates a 12 MHz Main Clock and a 32.768 kHz Slow Clock from external crystal networks or external clock sources. It provides various clock signals for the rest of the chip. It also provides the main system reset signal, a power-on reset function, Main Clock prescalers to generate two additional low-speed clocks, and a 32-kHz oscillator start-up delay. Figure 4 is block diagram of the Triple Clock and Reset module. TWM (Invalid Watchdog Service) Device Reset Flash Interface (Program/Erase Busy) Reset Module External Reset Stretched Reset Reset Power-On-Reset Module (POR) Stop Main Osc. Stop Main Osc Preset X1CKI Start-Up-Delay 14-Bit Timer High Frequency Oscillator Main Clock Div. by 2 4-Bit Aux1 Prescaler Auxiliary Clock 1 4-Bit Aux2 Prescaler Auxiliary Clock 2 8-Bit Prescaler Slow Clock Prescaler X2CKI Mux X1CKO Good Main Clock Low Frequency Oscillator Slow Clock Slow Clock Select Start-Up-Delay 8-Bit Timer Time-out Good Slow Clock Preset X2CKO Stop Slow Osc Bypass 32 kHz Osc Mux Fast Clock Prescaler 4-Bit Prescaler System Clock Mux Fast Clock Select PLL Clock PLL (x3, x4, or x5) Bypass PLL Good PLL Clock Stop PLL Stop PLL DS006 Figure 4. Triple Clock and Reset Module 51 www.national.com CP3CN23 11.0 Triple Clock and Reset CP3CN23 11.1 EXTERNAL CRYSTAL NETWORK An external crystal network is connected to the X1CKI and X1CKO pins to generate the Main Clock, unless an external clock signal is driven on the X1CKI pin. A similar external crystal network may be used at pins X2CKI and X2CKO for the Slow Clock. If an external crystal network is not used for the Slow Clock, the Slow Clock is generated by dividing the fast Main Clock. The crystal network you choose may require external components different from the ones specified in this datasheet. In this case, consult with National’s engineers for the component specifications X1CKI 12 MHz Crystal C1 X1CKO C2 The crystals and other oscillator components must be placed close to the X1CKI/X1CKO and X2CKI/X2CKO device input pins to keep the printed trace lengths to an absolute minimum. Figure 5 shows the external crystal network for the X1CKI and X1CKO pins. Figure 6 shows the external crystal network for the X2CKI and X2CKO pins. Table 21 shows the component specifications for the main crystal network, and Table 22 shows the component specifications for the 32.768 kHz crystal network. GND DS189 Figure 5. Main Clock External Crystal Network X2CKI C1 32.768 kHz Crystal X2CKO C2 GND DS215 Figure 6. Slow Clock External Crystal Network Table 21 Component Values of the High Frequency Crystal Circuit Component Crystal Capacitor C1, C2 www.national.com Parameters Resonance Frequency Type Max. Serial Resistance Max. Shunt Capacitance Load Capacitance Capacitance 52 Values Tolerance 12 MHz ± 20 ppm AT-Cut 50 Ω 7 pF 22 pF N/A 22 pF 20% Component Crystal Parameters Resonance Frequency Type Maximum Serial Resistance Maximum Shunt Capacitance Load Capacitance Min. Q factor Capacitor C1, C2 Capacitance Choose capacitor component values in the tables to obtain the specified load capacitance for the crystal when combined with the parasitic capacitance of the trace, socket, and package (which can vary from 0 to 8 pF). As a guideline, the load capacitance is: C1 × C2 CL = --------------------- + Cparasitic C1 + C2 C2 > C1 C1 can be trimmed to obtain the desired load capacitance. The start-up time of the 32.768 kHz oscillator can vary from one to six seconds. The long start-up time is due to the high Q value and high serial resistance of the crystal necessary to minimize power consumption in Power Save mode. Values Tolerance 32.768 kHz Parallel N-Cut or XY-bar 40 kΩ 2 pF 12.5 pF 40000 N/A 25 pF 20% the Good Slow Clock signal, which indicates that the Slow Clock is stable. For systems that do not require a reduced power consumption mode, the external crystal network may be omitted for the Slow Clock. In that case, the Slow Clock can be synthesized by dividing the Main Clock by a prescaler factor. The prescaler circuit consists of a fixed divide-by-2 counter and a programmable 8-bit prescaler register. This allows a choice of clock divisors ranging from 2 to 512. The resulting Slow Clock frequency must not exceed 100 kHz. A software-programmable multiplexer selects either the prescaled Main Clock or the 32.768 kHz oscillator as the Slow Clock. At reset, the prescaled Main Clock is selected, ensuring that the Slow Clock is always present initially. Selection of the 32.768 kHz oscillator as the Slow Clock dis11.2 MAIN CLOCK ables the clock prescaler, which allows the CLK1 oscillator The Main Clock is generated by the 12-MHz high-frequency to be turned off, which reduces power consumption and raoscillator or driven by an external signal (typically the diated emissions. This can be done only if the module deLMX5251 RF chip). It can be stopped by the Power Man- tects a toggling low-speed oscillator. If the low-speed agement Module to reduce power consumption during peri- oscillator is not operating, the prescaler remains available ods of reduced activity. When the Main Clock is restarted, a as the Slow Clock source. 14-bit timer generates a Good Main Clock signal after a 11.4 PLL CLOCK start-up delay of 32,768 clock cycles. This signal is an indiThe PLL Clock is generated by the PLL from the 12 MHz cator that the high-frequency oscillator is stable. Main Clock by applying a multiplication factor of ×3, ×4, or The Stop Main Osc signal from the Power Management ×5. Module stops and starts the high-frequency oscillator. When this signal is asserted, it presets the 14-bit timer to To enable the PLL: 3FFFh and stops the high-frequency oscillator. When the 1. Set the PLL multiplication factor in PRFSC.MODE. signal goes inactive, the high-frequency oscillator starts and 2. Clear the PLL power-down bit CRCTRL.PLLPWD. the 14-bit timer counts down from its preset value. When the timer reaches zero, it stops counting and asserts the Good 3. Clear the high-frequency clock select bit CRCTRL.FCLK. Main Clock signal. 4. Read CRCTRL.FCLK, and go back to step 3 if not clear. 11.3 SLOW CLOCK The CRCTRL.FCLK bit will be clear only after the PLL has The Slow Clock is necessary for operating the device in restabilized, so software must repeat step 3 until the bit is duced power modes and to provide a clock source for modclear. The clock source can be switched back to the Main ules such as the Timing and Watchdog Module. Clock by setting the CRCTRL.FCLK bit. The Slow Clock operates in a manner similar to the Main The PRSFC register must not be modified while the System Clock. The Stop Slow Osc signal from the Power ManageClock is derived from the PLL Clock. The System Clock ment Module stops and starts the low-frequency (32.768 must be derived from the low-frequency oscillator clock kHz) oscillator. When this signal is asserted, it presets a 6while the MODE field is modified. bit timer to 3Fh and disables the low-frequency oscillator. When the signal goes inactive, the low-frequency oscillator starts, and the 6-bit timer counts down from its preset value. When the timer reaches zero, it stops counting and asserts 53 www.national.com CP3CN23 Table 22 Component Values of the Low Frequency Crystal Circuit CP3CN23 11.5 SYSTEM CLOCK The System Clock drives most of the on-chip modules, including the CPU. Typically, it is driven by the Main Clock, but it can also be driven by the PLL. In either case, the clock signal is passed through a programmable divider (scale factors from ÷1 to ÷16). 11.6 rise time. The time constant also should exceed the stabilization time for the high-frequency oscillator. 11.9 Table 23 lists the clock and reset registers. Table 23 Clock and Reset Registers AUXILIARY CLOCKS Auxiliary Clock 1 and Auxiliary Clock 2 are generated from Main Clock for use by certain peripherals. Auxiliary Clock 1 is available for the Advanced Audio Interface. Auxiliary Clock 2 is available for the CVSD/PCM transcoder and the 12-bit ADC. The Auxiliary clocks may be configured to keep these peripherals running when the System Clock is slowed down or suspended during low-power modes. 11.7 Name Address Description CRCTRL FF FC40h Clock and Reset Control Register PRSFC FF FC42h High Frequency Clock Prescaler Register PRSSC FF FC44h Low Frequency Clock Prescaler Register PRSAC FF FC46h Auxiliary Clock Prescaler Register POWER-ON RESET The Power-On Reset circuit generates a system reset signal at power-up and holds the signal active for a period of time to allow the crystal oscillator to stabilize. The circuit detects a power turn-on condition, which presets a 14-bit timer driven by Main Clock to a value of 3FFFh. This preset value is defined in hardware and not programmable. Once oscillation starts and the clock becomes active, the timer starts counting down. When the count reaches zero, the 14-bit timer stops counting and the internal reset signal is deactivated (unless the RESET pin is held low). The circuit sets a power-on reset bit on detection of a poweron condition. The CPU can read this bit to determine whether a reset was caused by a power-up or by the RESET input. Note: The Power-On Reset circuit cannot be used to detect a drop in the supply voltage. 11.8 CLOCK AND RESET REGISTERS 11.9.1 Clock and Reset Control Register (CRCTRL) The CRCTRL register is a byte-wide read/write register that controls the clock selection and contains the power-on reset status bit. At reset, the CRCTRL register is initialized as described below: 7 6 Reserved SCLK EXTERNAL RESET The active-low RESET input can be used to reset the device at any time. When the signal goes low, it generates an internal system reset signal that remains active until the RESET FCLK signal goes high again. There is no internal pullup on this input, so it must be driven or pulled high externally for proper device operation. If the VCC power supply has slow rise-time. it may be necessary to use an external reset circuit to insure proper device initialization. Figure 7 shows an example of an external reset circuit. IOVCC IOVCC R CP3BT2x PLLPWD RESET C GND DS216 Figure 7. External Reset Circuit The value of R should be less than 50K ohms. The RC time constant of the circuit should be 5 times the power supply www.national.com 54 5 4 3 2 1 0 POR ACE2 ACE1 PLLPWD FCLK SCLK The Slow Clock Select bit controls the clock source used for the Slow Clock. 0 – Slow Clock driven by prescaled Main Clock. 1 – Slow Clock driven by 32.768 kHz oscillator. The Fast Clock Select bit selects between the 12 MHz Main Clock and the PLL as the source used for the System Clock. After reset, the Main Clock is selected. Attempting to switch to the PLL while the PLLPWD bit is set (PLL is turned off) is ignored. Attempting to switch to the PLL also has no effect if the PLL output clock has not stabilized. 0 – The System Clock prescaler is driven by the output of the PLL. 1 – The System Clock prescaler is driven by the 12-MHz Main Clock. This is the default after reset. The PLL Power-Down bit controls whether the PLL is active or powered down (Stop PLL signal asserted). When this bit is set, the on-chip PLL stays powered-down. Otherwise it is powered-up or it can be controlled by the Power Management Module, respectively. Before software can power-down the PLL in Active mode by setting the PLLPWD bit, the FCLK bit must be set. Attempting to set the PLLPWD bit while the FCLK bit is clear is ignored. The ACE1 ACE2 POR 11.9.2 Res FCDIV MODE 6 4 MODE 3 0 FCDIV Output Frequency (from 12 MHz input clock) Description 000 Reserved Reserved 001 Reserved Reserved 010 Reserved Reserved 011 36 MHz 3× Mode 100 48 MHz 4× Mode 101 60 MHz 5× Mode 110 Reserved Reserved 111 Reserved Reserved MODE2:0 11.9.3 Low Frequency Clock Prescaler Register (PRSSC) The PRSSC register is a byte-wide read/write register that holds the clock divisor used to generate the Slow Clock from the Main Clock. The register is initialized to B6h at reset. 7 0 SCDIV SCDIV High Frequency Clock Prescaler Register (PRSFC) The PRSFC register is a byte-wide read/write register that holds the 4-bit clock divisor used to generate the high-frequency clock. In addition, the upper three bits are used to control the operation of the PLL. The register is initialized to 4Fh at reset (except in PROG mode.) 7 low-frequency oscillator clock while the MODE field is modified. 11.9.4 The Slow Clock Divisor field specifies a divisor to be used when generating the Slow Clock from the Main Clock. The Main Clock is divided by a value of (2 × (SCDIV + 1)) to obtain the Slow Clock. At reset, the SCDIV register is initialized to B6h, which generates a Slow Clock rate of 32786.89 Hz. This is about 0.5% faster than a Slow Clock generated from an external 32768 Hz crystal network. Auxiliary Clock Prescaler Register (PRSAC) The PRSAC register is a byte-wide read/write register that holds the clock divisor values for prescalers used to generate the two auxiliary clocks from the Main Clock. The register is initialized to FFh at reset. 7 The Fast Clock Divisor specifies the divisor used to obtain the high-frequency System Clock from the PLL or Main Clock. The divisor is (FCDIV + 1). The PLL MODE field specifies the operation ACDIV1 mode of the on-chip PLL. After reset the MODE bits are initialized to 100b, so the PLL is configured to generate a 48-MHz clock. This register must not be modified when the ACDIV2 System Clock is derived from the PLL Clock. The System Clock must be derived from the 55 4 ACDIV2 3 0 ACDIV2 The Auxiliary Clock Divisor 1 field specifies the divisor to be used for generating Auxiliary Clock 1 from the Main Clock. The Main Clock is divided by a value of (ACDIV1 + 1). The Auxiliary Clock Divisor 2 field specifies the divisor to be used for generating Auxiliary Clock 2 from the Main Clock. The Main Clock is divided by a value of (ACDIV2 + 1). www.national.com CP3CN23 FCLK bit cannot be cleared until the PLL clock has stabilized. After reset this bit is set. 0 – PLL is active. 1 – PLL is powered down. When the Auxiliary Clock Enable bit is set and a stable Main Clock is provided, the Auxiliary Clock 1 prescaler is enabled and generates the first Auxiliary Clock. When the ACE1 bit is clear or the Main Clock is not stable, Auxiliary Clock 1 is stopped. Auxiliary Clock 1 is used as the clock input for the Advanced Audio Interface. After reset this bit is clear. 0 – Auxiliary Clock 1 is stopped. 1 – Auxiliary Clock 1 is active if the Main Clock is stable. When the Auxiliary Clock Enable 2 bit is set and a stable Main Clock is provided, the Auxiliary Clock 2 prescaler is enabled and generates Auxiliary Clock 2. When the ACE2 bit is clear or the Main Clock is not stable, the Auxiliary Clock 2 is stopped. Auxiliary Clock 2 is used as the clock input for the CVSD/PCM transcoder and the A/D converter. After reset this bit is clear. 0 – Auxiliary Clock 2 is stopped. 1 – Auxiliary Clock 2 is active if the Main Clock is stable. Power-On-Reset - The Power-On-Reset bit is set when a power-turn-on condition has been detected. This bit can only be cleared by software, not set. Writing a 1 to this bit will be ignored, and the previous value of the bit will be unchanged. 0 – Software cleared this bit. 1 – Software has not cleared his bit since the last reset. CP3CN23 12.0 Power Management The Power Management Module (PMM) improves the efficiency of the CP3CN23 by changing the operating mode (and therefore the power consumption) according to the required level of device activity. The device implements four power modes: * The Analog/Digital Converter (ADC) module is not automatically disabled by entering Halt mode, however its clock is stopped so no conversions may be performed in Halt mode. For maximum power savings, software must disable the ADC module before entering Halt mode. A module shown as On/Off in Table 25 may be enabled or disabled by software. A module shown as Active continues to operate even while its clock is suspended, which allows wake-up events to be processed during Idle and Halt modes. Active Power Save Idle Halt Table 24 summarizes the differences between power modes: the state of the high-frequency oscillator (on or off), the System Clock source (clock used by most modules), and the clock source used by the Timing and Watchdog Module (TWM). The high-frequency oscillator generates the 12-MHz Main Clock, and the low-frequency oscillator generates a 32.768 kHz clock. The Slow Clock can be driven by the 32.768 kHz clock or a scaled version of the Main Clock. Table 24 Power Mode Operating Summary High-Frequency Oscillator Mode Active On System Clock TWM Clock Main Clock Slow Clock Power Save On or Off Slow Clock Slow Clock Idle On or Off None Slow Clock Halt Off None None The low-frequency oscillator continues to operate in all four modes and power must be provided continuously to the device power supply pins. In Halt mode, however, Slow Clock does not toggle, and as a result, the TWM timer and Watchdog Module do not operate. For the Power Save and Idle modes, the high-frequency oscillator can be turned on or off under software control, as long as the low-frequency oscillator is used to drive Slow Clock. Table 25 shows the clock sources used by the CP3CN23 device modules and their behavior in each power mode. Table 25 Module Activity Summary Power Mode Module Power Active Save Idle Halt Clock Source Off Off System CPU On On/Off MIWU On On PMM On On On TWM On On On Active Active Active Slow Clock Slow Clock On/Off On/Off On/Off Off Aux 1 Clock CVSD/PCM On/Off On/Off On/Off Off Aux 2 Clock ADC On/Off On/Off On/Off Off* Aux 2 Clock All Others On/Off On/Off Off System AAI www.national.com Off 12.1 ACTIVE MODE In Active mode, the high-frequency oscillator is active and generates the 12-MHz Main Clock. The 32.768 kHz oscillator is active and may be used to generate the Slow Clock. The PLL can be active or inactive, as required. Most on-chip modules are driven by the System Clock. The System Clock can be the PLL Clock after a programmable divider or the 12-MHz Main Clock. The activity of peripheral modules is controlled by their enable bits. Power consumption can be reduced in this mode by selectively disabling modules and by executing the WAIT instruction. When the WAIT instruction is executed, the CPU stops executing new instructions until it receives an interrupt signal. After reset, the CP3CN23 is in Active Mode. 12.2 POWER SAVE MODE In Power Save mode, Slow Clock is used as the System Clock which drives the CPU and most on-chip modules. If Slow Clock is driven by the 32.768 kHz oscillator and no onchip module currently requires the 12-MHz Main Clock, software can disable the high-frequency oscillator to further reduce power consumption. Auxiliary Clocks 1 and 2 can be turned off under software control before switching to a reduced power mode, or they may remain active as long as Main Clock is also active. If the system does not require the PLL output clock, the PLL can be disabled. Alternatively, the Main Clock and the PLL can also be controlled by the Hardware Clock Control function, if enabled. The clock architecture is described in Section 11.0. In Power Save mode, some modules are disabled or their operation is restricted. Other modules, including the CPU, continue to function normally, but operate at a reduced clock rate. Details of each module’s activity in Power Save mode are described in each module’s descriptions. System Off The Random Number Generator (RNG) module has two oscillators which operate independently of the rest of the system. For maximum power savings, software must disable these oscillators. It is recommended to keep CPU activity at a minimum by executing the WAIT instruction to guarantee low power consumption in the system. 56 IDLE MODE 12.6 POWER MANAGEMENT REGISTERS In Idle mode, the System Clock is disabled and therefore the Table 26 lists the power management registers. clock is stopped to most modules of the device. The PLL Table 26 Power Management Registers and the high-frequency oscillator may be disabled as controlled by register bits. The low-frequency oscillator remains Name Address Description active. The Power Management Module (PMM) and the Timing and Watchdog Module (TWM) continue to operate Power Management PMMCR FF FC60h off the Slow Clock. Auxiliary Clocks 1 and 2 can be turned Control Register off under software control before switching to a power savPower Management ing mode, or they remain active as long as Main Clock is PMMSR FF FC62h Status Register also active. Alternatively, the 12 MHz Main Clock and the PLL can also be controlled by the Hardware Clock Control function, if enabled. 12.6.1 Power Management Control Register (PMMCR) 12.4 HALT MODE 12.5 HIGH-FREQUENCY OSCILLATOR AND PLL CONTROL The Power Management Control/Status Register (PMMCR) is a byte-wide, read/write register that controls the operating In Halt mode, all the device clocks, including the System power mode (Active, Power Save, Idle, or Halt) and enables Clock, Main Clock, and Slow Clock, are disabled. The highor disables the high-frequency oscillator in the Power Save frequency oscillator and PLL are turned off. The low-freand Idle modes. At reset, the non-reserved bits of this regquency oscillator continues to operate, however its circuitry ister are cleared. The format of the register is shown below. is optimized to guarantee lowest possible power consumption. This mode allows the device to reach the absolute min7 6 5 4 3 2 1 0 imum power consumption without losing its state (memory, registers, etc.). Reserved DHC DMC WBPSM HALT IDLE PSM Altogether, two mechanisms control whether the high-frequency oscillator is active, and three mechanisms control whether the PLL is active: PSM Disable Bits: The DMC and DHC bits in the PMMCR register may be used to disable the high-frequency oscillator and PLL, respectively, in Power Save and Idle modes. When used to disable the high-frequency oscillator or PLL, the DMC and DHC bits override the HCC mechanism. Power Management Mode: Halt mode disables the high-frequency oscillator and PLL. Active Mode enables them. The DMC and DHC bits and the HCC mechanism IDLE have no effect in Active or Halt mode. PLL Power Down Bit: The PLLPWD bit in the CRCTRL register can be used to disable the PLL in all modes. This bit does not affect the high-frequency oscillator. 57 If the Power Save Mode bit is clear and the WBPSM bit is clear, writing 1 to the PSM bit causes the device to start the switch to Power Save mode. If the WBPSM bit is set when the PSM bit is written with 1, entry into Power Save mode is delayed until execution of a WAIT instruction. The PSM bit becomes set after the switch to Power Save mode is complete. The PSM bit can be cleared by software, and it can be cleared by hardware when a hardware wake-up event is detected. 0 – Device is not in Power Save mode. 1 – Device is in Power Save mode. The Idle Mode bit indicates whether the device has entered Idle mode. The WBPSM bit must be set to enter Idle mode. When the IDLE bit is written with 1, the device enters IDLE mode at the execution of the next WAIT instruction. The IDLE bit can be set and cleared by software. It is also cleared by the hardware when a hardware wake-up event is detected. 0 – Device is not in Idle mode. 1 – Device is in Idle mode. www.national.com CP3CN23 12.3 CP3CN23 HALT WBPSM The Halt Mode bit indicates whether the de- DMC vice is in Halt mode. Before entering Halt mode, the WBPSM bit must be set. When the HALT bit is written with 1, the device enters the Halt mode at the execution of the next WAIT instruction. When in HALT mode, the PMM stops the System Clock and then turns off the PLL and the high-frequency oscillator. The HALT bit can be set and cleared by software. The Halt mode is exited by a hardware wake-up event. When this signal is set high, the oscillator is started. After the oscillator has stabilized, the HALT bit is cleared by the hardware. DHC 0 – Device is not in Halt mode. 1 – Device is in Halt mode. When the Wait Before Power Save Mode bit is clear, a switch from Active mode to Power Save mode only requires setting the PSM bit. When the WBPSM bit is set, a switch from Active mode to Power Save, Idle, or Halt mode is performed by setting the PSM, IDLE or HALT bit, respectively, and then executing a WAIT instruction. Also, if the DMC or DHC bits are set, the high-frequency oscillator and PLL may be disabled only after a WAIT instruction is executed and the Power Save, Idle, or Halt mode is entered. 0 – Mode transitions may occur immediately. 1 – Mode transitions are delayed until the next WAIT instruction is executed. www.national.com 58 The Disable Main Clock bit may be used to disable the high-frequency oscillator in Power Save and Idle modes. In Active mode, the high-frequency oscillator is enabled without regard to the DMC value. In Halt mode, the high-frequency oscillator is disabled without regard to the DMC value. The DMC bit is cleared by hardware when a hardware wakeup event is detected. 0 – High-frequency oscillator is only disabled in Halt mode or when disabled by the HCC mechanism. 1 – High-frequency oscillator is also disabled in Power Save and Idle modes. The Disable High-Frequency (PLL) Clock bit and the CRCTRL.PLLPWD bit may be used to disable the PLL in Power Save and Idle modes. When the DHC bit is clear (and PLLPWD = 0), the PLL is enabled in these modes. If the DHC bit is set, the PLL is disabled in Power Save and Idle mode. In Active mode with the CRCTRL.PLLPWD bit set, the PLL is enabled without regard to the DHC value. In Halt mode, the PLL is disabled without regard to the DMC value. The DHC bit is cleared by hardware when a hardware wake-up event is detected. 0 – PLL is disabled only by entering Halt mode or setting the CRCTRL.PLLPWD bit. 1 – PLL is also disabled in Power Save or Idle mode. 12.7 Power Management Status Register (PMMSR) The Management Status Register (PMMR) is a byte-wide, read/write register that provides status signals for the various clocks. The reset value of PMSR register bits 0 to 2 depend on the status of the clock sources monitored by the PMM. The upper 5 bits are clear after reset. The format of the register is shown below. 7 3 Reserved 2 1 OHC OMC SWITCHING BETWEEN POWER MODES Switching from a higher to a lower power consumption mode is performed by writing an appropriate value to the Power Management Control/Status Register (PMMCR). Switching from a lower power consumption mode to the Active mode is usually triggered by a hardware interrupt. Figure 8 shows the four power consumption modes and the events that trigger a transition from one mode to another. 0 Reset OLC WBPSM = 1 & HALT = 1 & "WAIT" OLC OMC OHC The Oscillating Low Frequency Clock bit indicates whether the low-frequency oscillator is producing a stable clock. When the low-frequency oscillator is unavailable, the PMM will not switch to Power Save, Idle, or Halt mode. 0 – Low-frequency oscillator is unstable, disabled, or not oscillating. 1 – Low-frequency oscillator is available. The Oscillating Main Clock bit indicates whether the high-frequency oscillator is producing a stable clock. When the high-frequency oscillator is unavailable, the PMM will not switch to Active mode. 0 – High-frequency oscillator is unstable, disabled, or not oscillating. 1 – High-frequency oscillator is available. The Oscillating High Frequency (PLL) Clock bit indicates whether the PLL is producing a stable clock. Because the PMM tests the stability of the PLL clock to qualify power mode state transitions, a stable clock is indicated when the PLL is disabled. This removes the stability of the PLL clock from the test when the PLL is disabled. When the PLL is enabled but unstable, the PMM will not switch to Active mode. 0 – PLL is enabled but unstable. 1 – PLL is stable or disabled (CRCTRL.PLLPWD = 0). Active Mode WBPSM = 0 & PSM = 1 or WBPSM = 1 & PSM = 1 & "WAIT" WBPSM = 1 & IDLE = 1 & "WAIT" Power Save Mode HW Event WBPSM = 1 & IDLE = 1 & "WAIT" Idle Mode HW Event IDLE = 1 Halt Mode HW Event Note: HW Event = MIWU wake-up or NMI DS008 Figure 8. Power Mode State Diagram Some of the power-up transitions are based on the occurrence of a wake-up event. An event of this type can be either a maskable interrupt or a non-maskable interrupt (NMI). All of the maskable hardware wake-up events are monitored by the Multi-Input Wake-Up (MIWU) Module, which is active in all modes. Once a wake-up event is detected, it is latched until an interrupt acknowledge cycle occurs or a reset is applied. A wake-up event causes a transition to the Active mode and restores normal clock operation, but does not start execution of the program. It is the interrupt handler associated with the wake-up source (MIWU or NMI) that causes program execution to resume. 12.7.1 Active Mode to Power Save Mode A transition from Active mode to Power Save mode is performed by writing a 1 to the PMMCR.PSM bit. The transition to Power Save mode is either initiated immediately or at execution of the next WAIT instruction, depending on the state of the PMMCR.WBPSM bit. For an immediate transition to Power Save mode (PMMCR.WBPSM = 0), the CPU continues to operate using the low-frequency clock. The PMMCR.PSM bit becomes set when the transition to the Power Save mode is completed. For a transition at the next WAIT instruction (PMMCR.WBPSM = 1), the CPU continues to operate in Active mode until it executes a WAIT instruction. At execution of the WAIT instruction, the device enters the Power Save mode, and the CPU waits for the next interrupt event. In this case, the PMMCR.PSM bit becomes set when it is written, even before the WAIT instruction is executed. 59 www.national.com CP3CN23 12.6.2 CP3CN23 12.7.2 Entering Idle Mode 12.7.6 Entry into Idle mode is performed by writing a 1 to the PMMCR.IDLE bit and then executing a WAIT instruction. The PMMCR.WBPSM bit must be set before the WAIT instruction is executed. Idle mode can be entered only from the Active or Power Save mode. 12.7.3 Wake-Up Transition to Active Mode A hardware wake-up event switches the device directly from Power Save, Idle, or Halt mode to Active mode. Hardware wake-up events are: Non-Maskable Interrupt (NMI) Valid wake-up event on a Multi-Input Wake-Up channel Disabling the High-Frequency Clock When a wake-up event occurs, the on-chip hardware perWhen the low-frequency oscillator is used to generate the forms the following steps: Slow Clock, power consumption can be reduced further in 1. Clears the PMMCR.DMC bit, which enables the highthe Power Save or Idle mode by disabling the high-frequenfrequency clock (if it was disabled). cy oscillator. This is accomplished by writing a 1 to the PM- 2. Waits for the PMMSR.OMC bit to become set, which inMCR.DHC bit before executing the WAIT instruction that dicates that the high-frequency clock is operating and puts the device in the Power Save or Idle mode. The highis stable. frequency clock is turned off only after the device enters the 3. Clears the PMMCR.DHC bit, which enables the PLL. Power Save or Idle mode. 4. Waits for the PMMSR.OHC bit to become set. The CPU operates on the low-frequency clock in Power 5. Switches the device into Active mode. Save mode. It can turn off the high-frequency clock at any 12.7.7 Power Mode Switching Protection time by writing a 1 to the PMMCR.DHC bit. The high-frequency oscillator is always enabled in Active mode and al- The Power Management Module has several mechanisms ways disabled in Halt mode, without regard to the to protect the device from malfunctions caused by missing or unstable clock signals. PMMCR.DHC bit setting. Immediately after power-up and entry into Active mode, software must wait for the low-frequency clock to become stable before it can put the device in Power Save mode. It should monitor the PMMSR.OLC bit for this purpose. Once this bit is set, Slow Clock is stable and Power Save mode can be entered. 12.7.4 Entering Halt Mode Entry into Halt mode is accomplished by writing a 1 to the PMMCR.HALT bit and then executing a WAIT instruction. The PMMCR.WBPSM bit must be set before the WAIT instruction is executed. Halt mode can be entered only from Active or Power Save mode. The PMMSR.OHC, PMMSR.OMC, and PMMSR.OLC bits indicate the current status of the PLL, high-frequency oscillator, and low-frequency oscillator, respectively. Software can check the appropriate bit before switching to a power mode that requires the clock. A set status bit indicates an operating, stable clock. A clear status bit indicates a clock that is disabled, not available, or not yet stable. (Except in the case of the PLL, which has a set status bit when disabled.) During a power mode transition, if there is a request to switch to a mode with a clear status bit, the switch is delayed until that bit is set by the hardware. When the system is built without an external crystal network Software-Controlled Transition to Active Mode for the low-frequency clock, Main Clock is divided by a presA transition from Power Save mode to Active mode can be caler factor to produce the low-frequency clock. In this situaccomplished by either a software command or a hardware ation, Main Clock is disabled only in the Halt mode, and wake-up event. The software method is to write a 0 to the cannot be disabled for the Power Save or Idle mode. 12.7.5 PMMCR.PSM bit. The value of the register bit changes only after the transition to the Active mode is completed. Without an external crystal network for the low-frequency clock, the device comes out of Halt or Idle mode and enters If the high-frequency oscillator is disabled for Power Save Active mode with Main Clock driving Slow Clock. operation, the oscillator must be enabled and allowed to sta- Note: For correct operation in the absence of a low-frebilize before the transition to Active mode. To enable the quency crystal, the X2CKI pin must be tied low (not left floathigh-frequency oscillator, software writes a 0 to the PM- ing) so that the hardware can detect the absence of the MCR.DMC bit. Before writing a 0 to the PMMCR.PSM bit, crystal. software must first monitor the PMMSR.OMC bit to determine when the oscillator has stabilized. www.national.com 60 The Multi-Input Wake-Up (MIWU) unit consists of two identical 16-channel modules. Each module can assert a wakeup signal for exiting from a low-power mode, and each can assert an interrupt request on any of four Interrupt Control Unit (ICU) channels assigned to that module. The modules operate independently, so each may assert an interrupt request to the ICU. Together, these modules provide 32 MIWU input channels and 8 interrupt request outputs. Each 16-channel module monitors its inputs for a softwareselectable trigger condition. On detection of a trigger condition, the module generates an interrupt request and if enabled, a wake-up request. A wake-up request can be used by the power management unit to exit the Halt, Idle, or Power Save mode and return to the Active mode. An interrupt request generates an interrupt to the CPU, which allows an interrupt handler to respond to MIWU events. rupt handler. Therefore, setting up the MIWU interrupt handler is essential for any wake-up operation. Each 16-channel module has four interrupt requests that can be routed to the ICU as shown in Figure 9. Each of the 16 channels can be programmed to activate one of these four interrupt requests. The 32 MIWU channels are named WUI0 through WUI31, as shown in Table 27. Each channel can be configured to trigger on rising or falling edges, as determined by the setting in the WK0EDG or WK1EDG register. Each trigger event is latched into the WK0PND or WK1PND register. If a trigger event is enabled by its respective bit in the WK0ENA or WK1ENA register, an active wake-up/interrupt signal is generated. Software can determine which channel has generated the active signal by reading the WK0PND or WK1PND register. The wake-up event only activates the clocks and CPU, but does not by itself initiate execution of any code. It is the in- The MIWU is active at all times, including the Halt mode. All terrupt request asserted by the MIWU that gets the CPU to device clocks are stopped in this mode. Therefore, detecting start executing code, by jumping to the corresponding inter- an external trigger condition and the subsequent setting of the pending bit are not synchronous to the System Clock. Peripheral Bus 15 ........... 0 WK0ICTL1/WK0ICTL2 WK1ICTL1/WK1ICTL2 WK0IENA WK1IENA WUI0 WUI16 0 Encoder 4 MIWU Interrupt 3:0 MIWU Interrupt 7:4 15 WUI15 WUI31 WK0EDG WK1EDG WK0PND WK1PND Wake-Up Signal To Power Mgt WK0ENA WK1ENA 15 ........... 0 DS218 Figure 9. Multi-Input Wake-Up Module Block Diagram 61 www.national.com CP3CN23 13.0 Multi-Input Wake-Up CP3CN23 13.1 Table 27 MIWU Sources MIWU Channel Source WUI0 TWM T0OUT WUI1 ACCESS.bus WUI2 CAN0RX WUI3 MWCS WUI4 UART0 CTS WUI5 UART0 RXD WUI6 Reserved WUI7 AAI SFS WUI8 Reserved WUI9 PJ7 WUI10 PG6 WUI11 PH0 WUI12 PH1 WUI13 PH2 WUI14 PH3 WUI15 PH4 WUI16 PH5 WUI17 PH6 WUI18 PJ0 WUI19 PJ1 WUI20 PJ2 WUI21 PJ3 WUI22 PJ4 WUI23 PJ5 WUI24 PJ6 WUI25 Reserved WUI26 UART1 RXD WUI27 UART2 RXD WUI28 UART3 RXD WUI29 Reserved WUI30 ADC Done WUI31 CAN1RX www.national.com MULTI-INPUT WAKE-UP REGISTERS Table 28 lists the MIWU registers. Table 28 Multi-Input Wake-Up Registers 62 Name Address Description WK0EDG FF FC80h Wake-Up Edge Detection Register Module 0 WK1EDG FF FCA0h Wake-Up Edge Detection Register Module 1 WK0ENA FF FC82h Wake-Up Enable Register Module 0 WK1ENA FF FCA2h Wake-Up Enable Register Module 1 WK0ICTL1 FF FC84h Wake-Up Interrupt Control Register 1 Module 0 WK1ICTL1 FF FCA4h Wake-Up Interrupt Control Register 1 Module 1 WK0ICTL2 FF FC86h Wake-Up Interrupt Control Register 2 Module 0 WK1ICTL2 FF FCA6h Wake-Up Interrupt Control Register 2 Module 1 WK0PND FF FC88h Wake-Up Pending Register Module 0 WK1PND FF FCA8h Wake-Up Pending Register Module 1 WK0PCL FF FC8Ah Wake-Up Pending Clear Register Module 0 WK1PCL FF FCAAh Wake-Up Pending Clear Register Module 1 WK0IENA FF FC8Ch Wake-Up Interrupt Enable Register Module 0 WK1IENA FF FCACh Wake-Up Interrupt Enable Register Module 1 13.1.4 Wake-Up Edge Detection Register (WK0EDG) The WK0EDG register is a word-wide read/write register that controls the edge sensitivity of the MIWU channels. The WK0EDG register is cleared upon reset, which configures all channels to be triggered on rising edges. The register format is shown below. 15 Wake-Up 1 Enable Register (WK1ENA) The WK1ENA register is a word-wide read/write register that individually enables or disables wake-up events from the MIWU channels. The WK1ENA register is cleared upon reset, which disables all wake-up/interrupt channels. The register format is shown below. 0 15 WKED 0 WKEN The Wake-Up Enable bits enable and disable The Wake-Up Edge Detection bits control the WKEN the MIWU channels. The WKEN15:0 bits coredge sensitivity for MIWU channels. The respond to the WUI31:16 channels, respecWKED15:0 bits correspond to the WUI15:0 tively. channels, respectively. 0 – MIWU channel wake-up events disabled. 0 – Triggered on rising edge (low-to-high transition). 1 – MIWU channel wake-up events enabled. 1 – Triggered on falling edge (high-to-low 13.1.5 Wake-Up Interrupt Enable Register (WK0IENA) transition). The WK0IENA register is a word-wide read/write register 13.1.2 Wake-Up 1 Edge Detection Register (WK1EDG) that enables and disables interrupts from the MIWU chanThe WK1EDG register is a word-wide read/write register nels. The register format is shown below. that controls the edge sensitivity of the MIWU channels. The WK1EDG register is cleared upon reset, which configures 15 0 all channels to be triggered on rising edges. The register forWKIEN mat is shown below. WKED 15 0 WKIEN WKED WKED 13.1.3 The Wake-Up Edge Detection bits control the edge sensitivity for MIWU channels. The WKED15:0 bits correspond to the WUI31:16 channels, respectively. 0 – Triggered on rising edge (low-to-high transition). 1 – Triggered on falling edge (high-to-low transition). 13.1.6 Wake-Up 1 Interrupt Enable Register (WK1IENA) The WK1IENA register is a word-wide read/write register that enables and disables interrupts from the MIWU channels. The register format is shown below. Wake-Up Enable Register (WK0ENA) The WK0ENA register is a word-wide read/write register that individually enables or disables wake-up events from the MIWU channels. The WK0ENA register is cleared upon reset, which disables all wake-up/interrupt channels. The register format is shown below. 15 15 0 WKIEN WK1IEN 0 WKEN WKEN The Wake-Up Interrupt Enable bits control whether MIWU channels generate interrupts. The WKIEN15:0 bits correspond to the WUI15:0 channels, respectively. 0 – Interrupt disabled. 1 – Interrupt enabled. The Wake-Up Interrupt Enable bits control whether MIWU channels generate interrupts. The WKIEN15:0 bits correspond to the WUI31:16 channels, respectively. 0 – Interrupt disabled. 1 – Interrupt enabled. The Wake-Up Enable bits enable and disable the MIWU channels. The WKEN15:0 bits correspond to the WUI15:0 channels, respectively. 0 – MIWU channel wake-up events disabled. 1 – MIWU channel wake-up events enabled. 63 www.national.com CP3CN23 13.1.1 CP3CN23 13.1.7 Wake-Up Interrupt Control Register 1 (WK0ICTL1) 13.1.9 Wake-Up Interrupt Control Register 2 (WK0ICTL2) The WK0ICTL1 register is a word-wide read/write register that selects the interrupt request signal for the associated MIWU channels WUI7:0. At reset, the WK0ICTL1 register is cleared, which selects MIWU Interrupt Request 0 for all eight channels. The register format is shown below. The WK0ICTL2 register is a word-wide read/write register that selects the interrupt request signal for the associated MIWU channels WUI15:8. At reset, the WK2ICTL2 register is cleared, which selects MIWU Interrupt Request 0 for all eight channels. The register format is shown below. 15 14 13 12 11 10 9 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0 WKIN WKIN WKIN WKIN WKIN WKIN WKIN WKIN TR7 TR6 TR5 TR4 TR3 TR2 TR1 TR0 WKINTR 13.1.8 8 7 6 5 4 3 2 1 0 WKIN WKIN WKIN WKIN WKIN WKIN WKIN WKIN TR15 TR14 TR13 TR12 TR11 TR10 TR9 TR8 The Wake-Up Interrupt Request Select fields WKINTR select which of the four MIWU interrupt requests are activated for the corresponding channel. 00 – Selects MIWU interrupt request 0. 01 – Selects MIWU interrupt request 1. 10 – Selects MIWU interrupt request 2. 11 – Selects MIWU interrupt request 3. Wake-Up 1 Interrupt Control Register 1 (WK1ICTL1) The Wake-Up Interrupt Request Select fields select which of the four MIWU interrupt requests are activated for the corresponding channel. 00 – Selects MIWU interrupt request 0. 01 – Selects MIWU interrupt request 1. 10 – Selects MIWU interrupt request 2. 11 – Selects MIWU interrupt request 3. 13.1.10 Wake-Up 1 Interrupt Control Register 2 (WK1ICTL2) The WK1ICTL1 register is a word-wide read/write register that selects the interrupt request signal for the associated MIWU channels WUI23:16. At reset, the WK1ICTL1 register is cleared, which selects MIWU Interrupt Request 4 for all eight channels. The register format is shown below. The WK1ICTL2 register is a word-wide read/write register that selects the interrupt request signal for the associated MIWU channels WUI31:24. At reset, the WK1ICTL2 register is cleared, which selects MIWU Interrupt Request 4 for all eight channels. The register format is shown below. 15 14 13 12 11 10 9 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0 WKIN WKIN WKIN WKIN WKIN WKIN WKIN WKIN TR23 TR22 TR21 TR20 TR19 TR18 TR17 TR16 WKINTR 7 6 5 4 3 2 1 0 WKIN WKIN WKIN WKIN WKIN WKIN WKIN WKIN TR31 TR30 TR29 TR28 TR27 TR26 TR25 TR24 The Wake-Up Interrupt Request Select fields WKINTR select which of the four MIWU interrupt requests are activated for the corresponding channel. 00 – Selects MIWU interrupt request 4. 01 – Selects MIWU interrupt request 5. 10 – Selects MIWU interrupt request 6. 11 – Selects MIWU interrupt request 7. www.national.com 8 64 The Wake-Up Interrupt Request Select fields select which of the four MIWU interrupt requests are activated for the corresponding channel. 00 – Selects MIWU interrupt request 4. 01 – Selects MIWU interrupt request 5. 10 – Selects MIWU interrupt request 6. 11 – Selects MIWU interrupt request 7. 13.1.13 Wake-Up Pending Clear Register (WK0PCL) The WK0PND register is a word-wide read/write register in which the Multi-Input Wake-Up module latches any detected trigger conditions. The CPU can only write a 1 to any bit position in this register. If the CPU attempts to write a 0, it has no effect on that bit. To clear a bit in this register, the CPU must use the WK0PCL register. This implementation prevents a potential hardware-software conflict during a read-modify-write operation on the WK0PND register. The WK0PCL register is a word-wide write-only register that lets the CPU clear bits in the WKPND register. Writing a 1 to a bit position in the WKPCL register clears the corresponding bit in the WKPND register. Writing a 0 has no effect. Do not modify this register with instructions that access the register as a read-modify-write operand, such as the bit manipulation instructions. This register is cleared upon reset. The register format is shown below. 15 0 Reading this register location returns undefined data. Therefore, do not use a read-modify-write sequence (such as the SBIT instruction) to set individual bits. Do not attempt to read the register, then perform a logical OR on the register value. Instead, write the mask directly to the register address. The register format is shown below. WKPD 15 WKPD The Wake-Up Pending bits indicate which MIWU channels have been triggered. The WKPD15:0 bits correspond to the WUI15:0 channels. Writing 1 to a bit sets it. WKCL 0 – Trigger condition did not occur. 1 – Trigger condition occurred. 13.1.12 Wake-Up 1 Pending Register (WK1PND) 0 WKCL Writing 1 to a bit clears it. 0 – Writing 0 has no effect. 1 – Writing 1 clears the corresponding bit in the WKPD register. The WK1PND register is a word-wide read/write register in which the Multi-Input Wake-Up module latches any detected trigger conditions. The CPU can only write a 1 to any bit position in this register. If the CPU attempts to write a 0, it has no effect on that bit. To clear a bit in this register, the CPU must use the WK1PCL register. This implementation prevents a potential hardware-software conflict during a read-modify-write operation on the WK1PND register. 13.1.14 Wake-Up 1 Pending Clear Register (WK1PCL) This register is cleared upon reset. The register format is shown below. Reading this register location returns undefined data. Therefore, do not use a read-modify-write sequence (such as the SBIT instruction) to set individual bits. Do not attempt to read the register, then perform a logical OR on the register value. Instead, write the mask directly to the register address. The register format is shown below. 15 0 WKPD WKPD The WK1PCL register is a word-wide write-only register that lets the CPU clear bits in the WK1PND register. Writing a 1 to a bit position in the WK1PCL register clears the corresponding bit in the WK1PND register. Writing a 0 has no effect. Do not modify this register with instructions that access the register as a read-modify-write operand, such as the bit manipulation instructions. 15 The Wake-Up Pending bits indicate which MIWU channels have been triggered. The WKPD15:0 bits correspond to the WUI31:15 channels. Writing 1 to a bit sets it. 0 – Trigger condition did not occur. WKCL 1 – Trigger condition occurred. 65 0 WKCL Writing 1 to a bit clears it. 0 – Writing 0 has no effect. 1 – Writing 1 clears the corresponding bit in the WK1PD register. www.national.com CP3CN23 13.1.11 Wake-Up Pending Register (WK0PND) CP3CN23 13.2 PROGRAMMING PROCEDURES To set up and use the Multi-Input Wake-Up function, use the following procedure. Performing the steps in the order shown will prevent false triggering of a wake-up condition. This same procedure should be used following a reset because the wake-up inputs are left floating, resulting in unknown data on the input pins. 1. Clear the WK0ENA and WK1ENA registers to disable the MIWU channels. 2. Write the WK0EDG and WK1EDG registers to select the desired type of edge sensitivity (clear for rising edge, set for falling edge). 3. Set all bits in the WK0PCL and WK0PCL registers to clear any pending bits in the WK0PND and WK1PND registers. 4. Set up the WK0ICTL1, WK1ICTL1, WK0ICTL2, and WK1ICTL2 registers to define the interrupt request signal used for each channel. 5. Set the bits in the WK0ENA and WK1ENA registers corresponding to the wake-up channels to be activated. To change the edge sensitivity of a wake-up channel, use the following procedure. Performing the steps in the order shown will prevent false triggering of a wake-up/interrupt condition. 1. Clear the WK0ENA or WK1ENA bit associated with the input to be reprogrammed. 2. Write the new value to the corresponding bit position in the WK0EDG or WK1EDG register to reprogram the edge sensitivity of the input. 3. Set the corresponding bit in the WK0PCL or WK1PCL register to clear the pending bit in the WK0PND or WK1PND register. 4. Set the same WK0ENA or WK1ENA bit to re-enable the wake-up function. www.national.com 66 Each device has up to 50 software-configurable I/O pins, organized into 8-bit ports (not all bits are used in some ports). The ports are named Port B, Port C, Port E, Port F, Port G, Port H, and Port J. In addition to their general-purpose I/O capability, the I/O pins of Ports E, F, G, H, and J have alternate functions for use with on-chip peripheral modules such as the UART or the Multi-Input Wake-Up unit. The alternate functions of all I/O pins are shown in Table 83. Ports B and C are used as the 16-bit data bus when an external bus is enabled (144-pin devices only). This alternate function is selected by enabling the DEV or ERE operating environments, not by programming the port registers. Different pins within the same port can be individually configured to operate in different modes. Figure 10 is a diagram showing the I/O port pin logic. The register bits, multiplexers, and buffers allow the port pin to be configured into the various operating modes. The output buffer is a TRI-STATE buffer with weak pull-up capability. The weak pull-up, if used, prevents the port pin from going to an undefined state when it operates as an input. To reduce power consumption, input buffers configured for general-purpose I/O are only enabled when they are read. When configured for an alternate function, the input buffers are enabled continuously. To minimize power consumption, input signals to enabled buffers must be held within 0.2 volts of the VCC or GND voltage. The I/O pin characteristics are fully programmable. Each pin can be configured to operate as a TRI-STATE output, push- The electrical characteristics and drive capabilities of the inpull output, weak pull-up input, or high-impedance input. put and output buffers are described in Section 28.0. D Q D Q D Q PxALTS Register VCC PxALT Register Weak Pull-Up Enable PxWKPU Register Alt. A Device Direction Output Enable Alt. B Device Direction D Q PxDIR Register Pin Alt. A Device Data Outout Data Out Alt. B Device Data Outout D Q PxDOUT Register Alt. A Data Input Data In PxDIN Register Alt. B Data Input 1 Data In Read Strobe DS190 Analog Input Figure 10. I/O Port Pin Logic Each port has an associated set of memory-mapped regis ters used for controlling the port and for holding the port da ta: 14.1 PORT REGISTERS 67 PxALT: Port alternate function register PxALTS: Port alternate function select register PxDIR: Port direction register PxDIN: Port data input register PxDOUT: Port data output register PxWPU: Port weak pull-up register PxHDRV: Port high drive strength register www.national.com CP3CN23 14.0 Input/Output Ports CP3CN23 Table 29 Port Registers Table 29 Port Registers Name PBALT Address FF FB00h Port B Direction Register PBDIN FF FB04h Port B Data Input Register PBDOUT FF FB06h Port B Data Output Register PBWPU FF FB08h Port B Weak Pull-Up Register PBHDRV FF FB0Ah Port B High Drive Strength Register FF FB0Ch Port B Alternate Function Select Register PCALT FF FB10h Port C Alternate Function Register PCDIR FF FB12h Port C Direction Register PCDIN FF FB14h Port C Data Input Register PCDOUT FF FB16h Port C Data Output Register PCWPU FF FB18h Port C Weak Pull-Up Register PCHDRV FF FB1Ah Port C High Drive Strength Register PEALT FF FB1Ch FF FCC0h Port E Direction Register PEDIN FF FCC4h Port E Data Input Register PEDOUT FF FCC6h Port E Data Output Register PEWPU FF FCC8h Port E Weak Pull-Up Register PEHDRV FF FCCAh Port E High Drive Strength Register FF FCCCh Port E Alternate Function Select Register FF FCE0h Port F Alternate Function Register PFDIR FF FCE2h Port F Direction Register PFDIN FF FCE4h Port F Data Input Register PFDOUT FF FCE6h Port F Data Output Register PFWPU FF FCE8h Port F Weak Pull-Up Register www.national.com FF FCEAh Port F High Drive Strength Register PFALTS FF FCECh Port F Alternate Function Select Register PGALT FF F300h Port G Alternate Function Register PGDIR FF F302h Port G Direction Register PGDIN FF F304h Port G Data Input Register PGDOUT FF F306h Port G Data Output Register PGWPU FF F308h Port G Weak Pull-Up Register PGHDRV FF F30Ah Port G High Drive Strength Register PGALTS FF F30Ch Port G Alternate Function Select Register PHALT FF F320h Port H Alternate Function Register PHDIR FF F322h Port H Direction Register PHDIN FF F324h Port H Data Input Register PHDOUT FF F326h Port H Data Output Register PHWPU FF F328h Port H Weak Pull-Up Register PHHDRV FF F32Ah Port H High Drive Strength Register PHALTS FF F32Ch Port H Alternate Function Select Register PJALT FF F340h Port J Alternate Function Register PJDIR FF F342h Port J Direction Register PJDIN FF F344h Port J Data Input Register PJDOUT FF F346h Port J Data Output Register PJWPU FF F348h Port J Weak Pull-Up Register PJHDRV FF F34Ah Port J High Drive Strength Register PJALTS FF F34Ch Port J Alternate Function Select Register Port E Alternate Function Register FF FCC2h PFALT PFHDRV Port C Alternate Function Select Register PEDIR PEALTS Description Port B Alternate Function Register FF FB02h PCALTS Address Description PBDIR PBALTS Name In the descriptions of the ports and port registers, the lowercase letter “x” represents the port designation, either B, C, E, F, G, H, or J. For example, “PxDIR register” means any one of the port direction registers: PBDIR, PCDIR, PEDIR, PFDIR, PGDIR, PHDIR, or PJDIR. 68 14.1.1 14.1.3 Port Data Input Register (PxDIN) The data input register (PxDIN) is a read-only register that returns the current state on each port pin. The CPU can read this register at any time even when the pin is configured as an output. Port Alternate Function Register (PxALT) 7 The PxALT registers control whether the port pins are used for general-purpose I/O or for their alternate function. Each port pin can be controlled independently. 0 PxDIN A clear bit in the alternate function register causes the corThe PxDIN bits indicate the state on the corresponding pin to be used for general-purpose I/O. In this PxDIN responding port pin. configuration, the output buffer is controlled by the direction 0 – Pin is low. register (PxDIR) and the data output register (PxDOUT). 1 – Pin is high. The input buffer is visible to software as the data input register (PxDIN). 14.1.4 Port Data Output Register (PxDOUT) A set bit in the alternate function register (PxALT) causes The data output register (PxDOUT) holds the data to be the corresponding pin to be used for its peripheral I/O funcdriven on output port pins. In this configuration, writing to tion. When the alternate function is selected, the output the register changes the output value. Reading the register buffer data and TRI-STATE configuration are controlled by returns the last value written to the register. signals from the on-chip peripheral device. A reset operation leaves the register contents unchanged. A reset operation clears the port alternate function regisAt power-up, the PxDOUT registers contain unknown valters, which initializes the pins as general-purpose I/O ports. ues. This register must be enabled before the corresponding alternate function is enabled. 7 0 7 PxDOUT 0 PxALT PxDOUT PxALT The PxDOUT bits hold the data to be driven on pins configured as outputs in general-purpose I/O mode. 0 – Drive the pin low. 1 – Drive the pin high. The PxALT bits control whether the corresponding port pins are general-purpose I/O ports or are used for their alternate function by an on-chip peripheral. 14.1.5 Port Weak Pull-Up Register (PxWPU) 0 – General-purpose I/O selected. 1 – Alternate function selected. The weak pull-up register (PxWPU) determines whether the port pins have a weak pull-up on the output buffer. The pull14.1.2 Port Direction Register (PxDIR) up device, if enabled by the register bit, operates in the genThe port direction register (PxDIR) determines whether eral-purpose I/O mode whenever the port output buffer is each port pin is used for input or for output. A clear bit in this disabled. In the alternate function mode, the pull-ups are alregister causes the corresponding pin to operate as an inways disabled. put, which puts the output buffer in the high-impedance state. A set bit causes the pin to operate as an output, which A reset operation clears the port weak pull-up registers, which disables all pull-ups. enables the output buffer. A reset operation clears the port direction registers, which initializes the pins as inputs. 7 0 PxWPU 7 0 PxDIR PxDIR PxWPU The PxDIR bits select the direction of the corresponding port pin. 0 – Input. 1 – Output. 69 The PxWPU bits control whether the weak pull-up is enabled. 0 – Weak pull-up disabled. 1 – Weak pull-up enabled. www.national.com CP3CN23 All of the port registers are byte-wide read/write registers, except for the port data input registers, which are read-only registers. Each register bit controls the function of the corresponding port pin. For example, PGDIR.2 (bit 2 of the PGDIR register) controls the direction of port pin PG2. CP3CN23 14.1.6 Port High Drive Strength Register (PxHDRV) Table 30 The PxHDRV register is a byte-wide, read/write register that controls the slew rate of the corresponding pins. The high drive strength function is enabled when the corresponding bits of the PxHDRV register are set. In both GPIO and alternate function modes, the drive strength function is enabled by the PxHDRV registers. At reset, the PxHDRV registers are cleared, making the ports low speed. 7 0 PxHDRV PxHDRV 14.1.7 The PxHDRV bits control whether output pins are driven with slow or fast slew rate. 0 – Slow slew rate. 1 – Fast slew rate. Port Alternate Function Select Register (PxALTS) The PxALTS register selects which of two alternate functions are selected for the port pin. These bits are ignored unless the corresponding PxALT bits are set. Each port pin can be controlled independently. 7 0 PxALTS PxALTS The PxALTS bits select among two alternate functions. Table 30 shows the mapping of the PxALTS bits to the alternate functions. Unused PxALTS bits must be clear. Table 30 Alternate Function Select Alternate Function Select Port Pin PxALTS = 0 PxALTS = 1 PF5 SFS TIO6 PF6 STD TIO7 PF7 SRD TIO8 PG0 Reserved Reserved PG1 Reserved Reserved PG2 Reserved SRCLK PG3 Reserved Reserved PG4 Reserved Reserved PG5 Reserved Reserved PG6 WUI10 Reserved PG7 TA Reserved PH0 UART1 RXD1 WUI11 PH1 UART1 TXD1 WUI12 PH2 UART2 RXD2 WUI13 PH3 UART2 TXD2 WUI14 PH4 UART3 RXD3 WUI15 PH5 UART3 TXD3 WUI16 PH6 CAN0RX WUI17 PH7 CAN0TX Reserved PJ0 WUI18 Reserved PJ1 WUI19 Reserved Port Pin PxALTS = 0 PxALTS = 1 PJ2 WUI20 Reserved PE0 UART0 RXD0 Reserved PJ3 WUI21 Reserved PE1 UART0 TXD0 Reserved PJ4 WUI22 Reserved PE2 UART0 RTS Reserved PJ5 WUI23 Reserved PE3 UART0 CTS Reserved PJ6 WUI24 Reserved PE4 UART0 CKX TB PJ7 ASYNC WUI9 PE5 SRFS NMI PE6 CAN1RX Reserved PE7 CAN1TX Reserved PF0 MSK TIO1 PF1 MDIDO TIO2 PF2 MDODI TIO3 PF3 MWCS TIO4 PF4 SCK TIO5 www.national.com 14.2 OPEN-DRAIN OPERATION A port pin can be configured to operate as an inverting open-drain output buffer. To do this, the CPU must clear the bit in the data output register (PxDOUT) and then use the port direction register (PxDIR) to set the value of the port pin. With the direction register bit set (direction = out), the value zero is forced on the pin. With the direction register bit clear (direction = in), the pin is placed in the TRI-STATE mode. If desired, the internal weak pull-up can be enabled to pull the signal high when the output buffer is in TRISTATE mode. 70 CP3CN23 15.0 12-Bit Analog to Digital Converter The integrated 12-bit ADC provides the following features: 8-input analog multiplexer 8 single-ended channels or 4 differential channels External filtering capability 12-bit resolution with 11-bit accuracy Sign bit MUXOUT0 MUXOUT1 ADCIN 15-microsecond conversion time Support for resistive touchscreen interface Internal or external start trigger Programmable start delay after start trigger Poll or interrupt on done VREFP AVCC ADC0 ADC1 AGND ADC2 ADC3 Pen-Down Detector ADC0/TSX+ PREF_CFG NREF_CFG DRV ADC1/TSYDRV ADC2/TSXDRV ADC3/TSY+ VREFP Int/Ext Multiplexer Input + Multiplexer VREFN + 12-BIT ADC Clock DRV Control Result ADC4 12 ADCIN Pen Down Wake-Up (WUI30) ADC7 TOUCH_CFG MUX_CFG ADC Clock ADC_DIV ASYNC TRIGGER DELAY1 ADC_CONTROL ADC_DELAY1 ADC SEQUENCER Start CLKDIV CLKSEL System Clock Done DELAY2 4-Word FIFO ADC_DELAY2 ADCRESLT Interrupt (IRQ13) System Bus Interface Auxiliary Clock 2 DS183 Figure 11. 15.1 Analog to Digital Converter Block Diagram FUNCTIONAL DESCRIPTION The ADC module consists of a 12-bit ADC converter and associated state machine, together with analog multiplexers to set up signal paths for sampling and voltage references, logic to control triggering of the converter, and a bus interface. 15.1.1 Data Path Up to 8 GPIO pins may be configured as 8 singled-ended analog inputs or 4 differential pairs. Analog/digital data passes through four main blocks in the ADC module between the input pins and the CPU bus: Input Multiplexer—an analog multiplexer that selects among the input channels. Internal/External Multiplexer—an analog multiplexer that selects between the output of the Input Multiplexer and the ADCIN external analog input. 12-Bit ADC—receives the output of the Internal/External Multiplexer and performs the analog to digital conversion. ADCRESLT Register—makes conversion results from the 12-Bit ADC available to the on-chip bus. The ADCRESLT register includes the software-visible end of a 4word FIFO used to queue conversion results. The configuration of the analog signal paths is controlled by fields in the ADCGCR register. The Input Multiplexer is controlled by the MUX_CFG field. The Internal/External Multiplexer is controlled by the ADCIN bit. The analog multiplexers for selecting the voltage references used by the ADC are controlled by the PREF_CFG and NREF_CFG fields. The low-ohmic drivers used for interface to resistive touchscreens are controlled by the TOUCH_CFG field. 71 www.national.com CP3CN23 The output of the Input Multiplexer is available externally as the MUXOUT0 and MUXOUT1 signals. In single-ended mode, only MUXOUT0 is used. In differential mode, MUXOUT0 is the positive side and MUXOUT1 is the negative side. The MUXOUT0 and MUXOUT1 outputs and the ADCIN external analog input are provided so that external signal conditioning circuits (such as filters) may be applied to the analog signals before conversion. The MUXOUT0, MUXOUT1, and ADCIN signals are alternate functions of GPIO pins used by the Input Multiplexer, so the number of available analog input channels is reduced when these signals are used. The Done signal is also an input to the Multi-Input Wake-Up unit (WUI30). The MIWU input is asserted whenever the FIFO is not empty (but will deassert for one system clock after the ADCRESLT register is read). The wake-up output is provided so that the ADC module can bring the system out of a power-saving mode when a conversion operation is completed. It asserts earlier than the interrupt output. In the pen-down detection mode of the ADC, the wake-up output is ORed with the ADC pen-down detector output, to wake up on a pen-down event. 15.1.2 15.1.3 Operation The TRIGGER block may be configured to initiate a conversion from either of these sources: one system clock after the ADCRESLT register is read). Total conversion time is around 15 microseconds. ADC Clock Generation The DELAY2 block generates ADC Clock, which is the clock used internally by the ADC module. ADC Clock is derived from either: External ASYNC Input—an edge on the ASYNC input triggers a conversion. This input may be configured to be System Clock—a programmable divider is available to sensitive to rising or falling edges, as controlled by the generate the 12 MHz clock required by the ADC from the POL bit in the ADCCNTRL register. System Clock. ADCSTART Register—writing any value to the ADC- Auxiliary Clock 2—may be used to perform conversions START register triggers a conversion. when the System Clock is slowed down or suspended in The TRIGGER block incorporates a glitch filter to suppress low-power modes. transient spikes on the ASYNC input. The TRIGGER block The DELAY2 block receives the clock source selected by will recognize ASYNC pulse widths of 10 ns or greater. the CLKSEL bit of the ADCACR register and adds a number Once a trigger event has been recognized, no further trig- of asynchronous incremental delay units specified in the gering is recognized until the conversion is completed. ADC_DELAY2 field of the ADCSCDLY register. This deWhen the ASYNC input is selected as the trigger source, it layed clock (ADC Clock) then drives the TRIGGER, 12-BIT may be configured for automatic or non-automatic mode, as ADC, and ADC SEQUENCER blocks. ADC Clock also controlled by the AUTO bit in the ADCCNTRL register: drives the ADC_DIV clock divider, which generates the Automatic Mode—a conversion is triggered by any clock which drives the DELAY1 block. qualified edge on the ASYNC input (unless a conversion is already in progress). Non-Automatic Mode—before a conversion may be triggered from the ASYNC input, software must “prime” the TRIGGER block by writing the ADCSTART register. Once the TRIGGER block is primed, a conversion is triggered by any qualified edge on the ASYNC input. After the conversion is completed, no additional trigger events will be recognized until software once again primes the TRIGGER block by writing the ADCSTART register. Once a trigger event is recognized, the DELAY1 block waits for a programmable delay specified in the ADC_DELAY1 field of the ADCSCDLY register. Then, it asserts the Start signal to the ADC SEQUENCER block. When the Start signal is received, the ADC SEQUENCER block initiates the conversion in the 12-Bit ADC. After the conversion is complete, the result is loaded into the FIFO, and the Done signal is asserted. The ADCRESLT register includes the software-visible end of a 4-word FIFO, which allows up to 4 conversion results to be queued for reading. Reading the ADCRESLT register unloads the FIFO. If the FIFO overflows, a bit is set in the ADCRESLT register, and the most recent conversion data is lost. The Done signal is visible to software as the ADC_DONE bit in the ADCRESLT register. The Done signal is also an input to the interrupt controller (IRQ13). The interrupt will be asserted whenever the FIFO is not empty (but will deassert for www.national.com 72 Because the ADCRESLT FIFO is driven by System Clock (not ADC Clock), a conversion result will not propagate to the output of the FIFO when the System Clock is suspended. 15.1.4 ADC Voltage References The 12-BIT ADC block has positive and negative voltage reference inputs, VREFP and VREFN. In single-ended mode, only VREFP is used. An analog multiplexer allows selecting an external VREFP pin, the analog supply voltage AVCC, or the analog inputs ADC0 or ADC1 as the positive voltage reference, as controlled by the PREF_CFG field of the ADCGCR register. Another analog multiplexer allows selecting the analog ground AGND or the analog inputs ADC2 or ADC3 as the negative voltage reference, as controlled by the NREF_CFG field of the ADCGCR register. 15.1.5 Pen-Down Detector A pen-down detector is provided on the ADC0 (TSX+) input of the ADC. It consists of a Schmitt-trigger receiver, with a minimum Vil of 0.7V. When pen-down detect mode is enabled by loading 101b into the TOUCH_CFG field of the ADCGCR register, the output of this detector is visible to software in the PEN_DOWN bit of the ADCRESLT register, and this output is ORed with the Done signal to become the wake-up input (WUI30) to the Multi-Input Wake-Up unit. TOUCHSCREEN INTERFACE 15.2.1 The ADC provides an interface for 4-wire resistive touchscreens with the resolution necessary for applications such as signature analysis. A typical touchscreen configuration is shown in Figure 12. Touchscreen Driver Configuration An equivalent circuit for the touchscreen interface is shown in Figure 13. VCC TSX+/ADC0 TSY+/ADC1 6Ω 6Ω TSY+ TSX-/ADC2 TSX+ X Plate TSY-/ADC3 Y Plate RX1 A To ADC RX2 MUXOUT0 RY1 RZ B RY2 TSX- ADCIN TSY- DS186 6Ω Figure 12. Touchscreen Interface 6Ω A touchscreen consists of two resistive plates normally separated from each other. The TSX+ and TSX- signals are connected to opposite ends of the X plate, while the TSY+ and TSY- signals are connected to the Y plate. If the pen is DS187 down, the plates will be shorted together at the point of pen contact. The location of the pen is sensed by driving one Figure 13. Touchscreen Driver Equivalent Circuit end of a plate to VCC, driving the opposite end to ground, and sensing the voltage at the point of pen contact using the Low-ohmic drivers are provided to pull the TSX+ and TSY+ signals to VCC and the TSX- and TSY- signals to GND. The other plate. This is done twice, once for each coordinate. on-resistance of these drivers is specified to be 6 ohms. An external RC low-pass filter is used to remove noise couTwo measurements are used to produce one (x,y) position pled to the touchscreen signals from the display drivers. coordinate pair. To measure the x-coordinate, the TSX+ signal is pulled to VCC, the TSX- signal is pulled to GND, and the TSY+ and TSY- signals are undriven. A voltage divider is formed across the X plate, with the center tap of the divider being the point of pen contact, represented in Figure 13 by node A. With TSY+ and TSY- undriven, the voltage at node A can be measured by sampling either of the TSY+ or TSY- signals. This voltage will be proportional to the position of the pen contact on the X plate. The position of the pen contact on the Y plate is measured similarly, by driving the TSY+ signal to VCC, the TSY- signal to GND, and leaving the TSX+ and TSX- signals undriven. The voltage at node B can be sampled from either the TSX+ or TSX- signals. The TOUCH_CFG field of the ADCGCR register specifies the configuration of the drivers, with 010b used to sample node A and 001b used to sample node B. Typically, two consecutive measurements are made of each coordinate so that any interference coupled from the LCD column drivers is averaged out. The plate-to-plate resistance is shown in Figure 13 as RZ. This measurement is used as an indication of the force of pen contact. When 100b is loaded into the TOUCH_CFG field, the TSY+ signal is pulled to VCC and the TSX- signal is pulled to GND, to support measuring RZ. 73 www.national.com CP3CN23 15.2 CP3CN23 15.2.2 Measuring Pen Force Solving for RY1, the resistance is: Figure 14 shows equivalent circuits for the driver modes used to measure the X, Y, and Z coordinates, in which Z represents pen force. In this discussion, the ohmic resistance of the drivers is neglected (see Section 15.2.3), and series resistance between the node of interest and the ADC is ignored because it has no significant effect. VCC VCC RY1 A RX2 Now that the resistance values RX2 and RY1 are known, it is possible to calculate the value of the plate-to-plate contact resistance, RZ, given the value measured at node C on the TSX+ input in Sample Z mode. Node C is a tap in a resistor-divider network composed of three resistors, such that: C RX2 ------------- = ---------------------------------------------2047 RY1 + RZ + RX2 RY1 VCC RX1 B RY1 = RYP × 1 – ------------- 2047 Solving for RZ, the resistance is: 2047 – C RZ = RX2 × ----------------------- – RY1 C RZ B RY2 C The resistance RZ is proportional to the force of pen contact. RX2 15.2.3 Sample X TOUCH_CFG = 001 Sample Y TOUCH_CFG = 010 Sample Z TOUCH_CFG = 100 DS188 Figure 14. Touchscreen Driver Modes In the following examples, the ADC is assumed to operate in single-ended mode to produce conversion values between 0 and 2047, however the same principles could be extended to differential mode to recover the full range of the ADC. In Sample X mode, the X plate is driven between VCC and ground, so that a value measured at node A on the TSY+ or TSY- inputs is the center tap of a resistor-divider network. The end-to-end resistance RXP of the X plate is: RXP = RX1 + RX2 Compensation for Driver Resistance Plate resistances between opposite electrodes range from 100 ohms to 1k ohm. Because of the 6-ohm driver resistance, some significant voltage drop will be experienced between, for example, TSX- and AGND. A 200-ohm plate will drop: 6 ---------------------------- 200 + 6 + 6 × ( AVCC – AGND ) With a 2.5V supply, this is 70 mV. A 12-bit ADC has 4096 possible values, so each value covers a range of 610 µV at 2.5V. A voltage drop of 70 mV across each of the low-ohmic drivers reduces the number of available ADC values by: 70 mV × 2 -------------------------= 230 610 uV This effective loss of resolution can be handled in a number The value measured at node A is proportional to the ratio of ways. between the resistance to ground and the resistance of the 1. The voltages on, for example, TSY+ and TSY- can be X plate: sampled before sampling TSX+ and TSX-. Then, scalA RX2 ing can be applied in software to convert the samples ------------- = ------------2047 RXP to the full (4096-bit) range. This technique will not recover any resolution, however it is worthy of some conSolving for RX2, the resistance is: sideration because touchscreen data is typically A RX2 = RXP × ------------- passed to two applications: 2047 Signature Analysis—only the raw data is required. No absolute positioning is necessary. Similarly, in Sample Y mode the value measured at node B Screen Overlay—for example, for cursor positioning. on the TSX+ or TSX- inputs is proportional to the ratio beIn this application, a scaling or calibration is performed tween the resistance to ground and the resistance RYP of to correctly overlay the touchscreen coordinates onto the Y plate: the display. Because of this calibration, it is not even B RY2 ------------- = ------------necessary to sample TSY+ and TSY-. 2047 RYP 2. The ADC has a positive voltage reference input which Because end-to-end resistance RYP of the Y plate is: can be internally connected to the TSY+ terminal. This means that the number of available ADC values is inRYP = RY1 + RY2 creased to: The previous equation can be rewritten as: 70 mV 4096 – -------------------- = 3981 B RYP – RY1 610 uV ------------- = ------------------------------2047 RYP Software scaling could be applied to this value if required (as with technique 1, above), but no additional resolution is achieved. www.national.com 74 15.5 Table 31 lists the ADC registers. The Global Configuration Register (ADCGCR) provides the flexibility to implement any of these techniques. 15.3 ADC REGISTER SET ADC OPERATION IN POWER-SAVING MODES To reduce the level of switching noise in the environment of the ADC, it is possible to operate the CP3CN23 in low-power modes, in which the System Clock is slowed or switched off. Under these conditions, Auxiliary Clock 2 can be selected as the clock source for the ADC module, however conversion results cannot be read by the system while the System Clock is suspended. The expected operation in power-saving modes is therefore: 1. ADC is configured and a conversion is primed or triggered. 2. A power-saving mode is entered. 3. ADC conversion completes and a wake-up signal is asserted to the MIWU unit. 4. Device wakes up and processes the conversion result. Table 31 ADC Registers Name Address Description ADCGCR FF F3C0h ADC Global Configuration Register ADCACR FF F3C2h ADC Auxiliary Configuration Register ADCCNTRL FF F3C4h ADC Conversion Control Register ADCSTART FF F3C6h ADC Start Conversion Register ADCSCDLY FF F3C8h ADC Start Conversion Delay Register ADCRESLT FF F3CAh ADC Result Register To conserve power, the ADC should be disabled before entering a low-power mode if its function is not required. 15.4 FREEZE The ADC module provides support for an In-System Emulator by means of a special FREEZE input. When FREEZE is asserted the module will exhibit the following specific behavior: The automatic clear-on-read function of the result register (ADCRESLT) is disabled. The FIFO is updated as usual, and an interrupt for a completed conversion can be asserted. 75 www.national.com CP3CN23 3. By extension, the ADC negative voltage reference can be internally connected to the TSY- terminal, to recover the full 4096 values. CP3CN23 15.5.1 ADC Global Configuration Register (ADCGCR) MUX_CFG The ADCGCR register controls the basic operation of the interface. The CPU bus master has read/write access to the ADCGCR register. After reset this register is set to 0000h. 8 7 6 5 TOUCH_CFG 15 4 3 MUX_CFG 14 13 2 Table 32 MUX_CFG Operation 0 DIFF ADCIN CLKEN 12 MUXOUTEN INTEN Res. 1 The Multiplexer Configuration field and the DIFF bit configure the analog circuits of the ADC module, as shown in Table 32. 11 NREF_CFG 10 MUX_CFG Channel Selected, (DIFF = 0) Channels Selected (DIFF = 1) + - 9 PREF_CFG 000 0 0 1 001 1 1 0 010 2 2 3 The Clock Enable bit controls whether the ADC module is running. When this bit is clear, 011 3 3 2 all ADC clocks are disabled, the ADC analog circuits are in a low-power state, and ADC 100 4 4 5 registers (other than the ADCGCR and AG101 5 5 4 CACR registers) are not writeable. Clearing this bit reinitializes the ADC state machine 110 6 6 7 and cancels any pending trigger event. When 111 7 7 6 this bit is set, the ADC clocks are enabled and the ADC analog circuits are powered up. The converter is operational within 0.25 µs of beFor best noise immunity in touchscreen appliing enabled. cations, channel 2 should be used for sam0 – ADC disabled. pling the X plate voltage, and channel 1 1 – ADC enabled. should be used for sampling the Y plate voltThe ADCIN bit selects the source of the ADC age. input. When the bit is clear, the source is the TOUCH_CFG The Touchscreen Configuration field controls 8-channel Input Multiplexer. When the bit is the configuration of the low-ohmic drivers for set, the source is the ADCIN pin. the TSX+, TSX-, TSY+, and TSY- signals, as 0 – ADC input is from 8-channel multiplexer. shown in Table 33. When TOUCH_CFG is 1 – ADC input is from ADCIN pin. 101b, the pen-down detector is enabled. The The Differential Operation Mode bit and the output of the pen-down detector is visible to MUX_CFG field configure the analog circuits software in the PEN_DOWN bit of the ADof the ADC module. When this bit is clear, the SRESLT register, and it is ORed with the ADC module operates in single-ended mode. Done signal to generate the wake-up signal When this bit is set, the ADC operates in difWUI30 passed to the MIWU unit. ferential mode. See Table 32 . 0 – Single-ended mode. 1 – Differential mode. CLKEN ADCIN DIFF Table 33 TOUCH_CFG Modes TOUCH_CFG ADC0/TSX+ ADC1/TSY+ ADC2/TSX- ADC3/TSY- Mode 000 Inactive Inactive Inactive Inactive None 001 Inactive Driven High Inactive Driven Low Sample Y 010 Driven High Inactive Driven Low Inactive Sample X 011 Driven High Inactive Inactive Driven Low Sample Z (1), Pre-Pen Down 100 Inactive Driven High Driven Low Inactive Sample Z (2) 101 Weakly Pulled High Inactive Inactive Driven Low Pen-Down Detect 11X Inactive Inactive Inactive inactive Reserved www.national.com 76 PREF_CFG PREF Source 00 Internal (AVCC) 01 VREFP 10 ADC0 11 ADC1 15.5.2 ADC Auxiliary Configuration Register (ADCACR) The ADCACR register is used to control the clock configuration and report the status of the ADC module. The CPU bus master has read/write access to the ADCACR register. After reset, this register is clear. 15 14 13 CNVT TRG CLKSEL NREF_CFG The Negative Voltage Reference Configuration field specifies the source of the ADC negative voltage reference, according to the following table: CLKDIV 12 PRM 3 Reserved 2 1 The Clock Select bit selects the clock source used by the DELAY2 block to generate the ADC clock. 0 – ADC clock derived from System Clock. 1 – ADC clock derived from Auxiliary Clock 2. The Clock Divisor field specifies the divisor applied to System Clock to generate the 12 MHz clock required by the ADC module. Only the System Clock is affected by this divisor. The divisor is not used when Auxiliary Clock 2 is selected as the clock source. NREF_CFG NREF source 00 Internal (AGND) 01 Reserved 10 ADC2 CLKDIV Clock Divisor 11 ADC3 00 1 01 2 10 4 11 Reserved MUXOUTEN The MUXOUT Enable bit controls whether the output of the Input Multiplexer is available externally. In single-ended mode, the MUXOUT0 pin is active and the MUXOUT1 pin is disabled (TRI-STATE). In differential mode, both MUXOUT0 and MUXOUT1 are PRM active. 0 – MUXOUT0 and MUXOUT1 disabled. 1 – MUXOUT0 and MUXOUT1 enabled. INTEN The Interrupt Enable bit controls whether the ADC interrupt (IRQ13) is enabled. When enabled, the interrupt request is asserted when valid data is available in the ADCRESLT reg- TRG ister. This bit has no effect on the wake_up signal to the MIWU unit (WUI30). 0 – IRQ13 disabled. 1 – IRQ13 enabled. CNVT 77 0 CLKDIV CLKSEL The ADC Primed bit is a read-only bit that indicates the ADC has been primed to perform a conversion by writing to the ADCSTART register. The bit is cleared after the conversion is completed. 0 – ADC has not been primed. 1 – ADC has been primed. The ADC Triggered bit is a read-only bit that indicates the ADC has been triggered. The bit is set during any pre-conversion delay. The bit is cleared after the conversion is completed. 0 – ADC has not been triggered. 1 – ADC has been triggered. The ADC Conversion bit is a read-only bit that indicates the ADC has been primed to perform a conversion, a valid internal or external trigger event has occurred, any pre-conversion delay has expired, and the ADC conversion is in progress. The bit is cleared after the conversion is completed. 0 – ADC is not performing a conversion. 1 – ADC conversion is in progress. www.national.com CP3CN23 PREF_CFG The Positive Voltage Reference Configuration field specifies the source of the ADC positive voltage reference, according to the following table: CP3CN23 15.5.3 ADC Conversion Control Register (ADCCNTRL) 15.5.4 The ADCCNTRL register specifies the trigger conditions for an ADC conversion. 15 3 Reserved POL EXT AUTO 2 1 AUTO EXT 0 The ADCSTART register is a write-only register used by software to initiate an ADC conversion. Writing any value to this register will cause the ADC to initiate a conversion or prime the ADC to initiate a conversion, as controlled by the ADCCNTRL register. 15.5.5 POL The ASYNC Polarity bit specifies the polarity of edges which trigger ADC conversions. 0 – ASYNC input is sensitive to rising edges. 1 – ASYNC input is sensitive to falling edges. The External Trigger bit selects whether conversions are triggered by writing the ADCSTART register or activity on the ASYNC input. 0 – ADC conversions triggered by writing to the ADCSTART register. 1 – ADC conversions triggered by qualified edges on ASYNC input. The Automatic bit controls whether automatic mode is enabled, in which any qualified edge on the ASYNC input is recognized as a trigger event. When automatic mode is disabled, the ADC module must be “primed” before a qualified edge on the ASYNC input can trigger a conversion. To prime the ADC module, software must write the ADCSTART register with any value before an edge on the ASYNC input is recognized as a trigger event. After the conversion is completed, the ASYNC input will be ignored until software again writes the ADCSTART register. The AUTO bit is ignored when the EXT bit is 0. 0 – Automatic mode disabled. 1 – Automatic mode enabled. ADC Start Conversion Register (ADCSTART) ADC Start Conversion Delay Register (ADCSCDLY) The ADCSCDLY register controls critical timing parameters for the operation of the ADC module. 15 14 ADC_DIV 13 5 ADC_DELAY1 4 ADC_DELAY2 ADC_DELAY2 The ADC Delay 2 field specifies the delay between the ADC module clock source (either System Clock after a programmable divider or Auxiliary Clock 2) and the ADC clock. The range of effective values for this field is 0 to 20. Values above 20 produce the same delay as 20, which is about 42 ns. ADC_DELAY1 The ADC Delay 1 field specifies the number of clock periods by which the trigger event will be delayed before initiating a conversion. The timebase for this delay is the ADC clock (12 MHz) divided by the ADC_DIV divisor. The ADC_DELAY1 field has 9 bits, which corresponds to a maximum delay of 511 clock periods. ADC_DIV The ADC Clock Divisor field specifies the divisor applied to the ADC clock (12 MHz) to generate the clock used to drive the DELAY1 block. A field value of n results in a division ratio of n+1. With a module clock of 12 MHz, the maximum delay which can be provided by ADC_DIV and ADC_DELAY settings is: 1 ------------------ 12 MHz × 4 × 511 = 170 us www.national.com 78 0 ADC Result Register (ADCRESLT) The ADCRESLT register includes the software-visible end of a 4-word FIFO. Conversion results are loaded into the FIFO from the 12-bit ADC and unloaded when software reads the ADCRESLT register. The ADCRESLT register is read-only. With the exception of the PEN_DOWN bit, the fields in this register are cleared when the register is read. 11 0 ADC_RESULT 15 14 13 ADC_DONE ADC_OFLW PEN_DOWN 12 SIGN ADC_RESULT The ADC Result field holds a 12-bit value for the conversion result. If the ADC_DONE bit is clear, there is no valid result in this field, and the field will have a value of 0. The ADC_RESULT field and the SIGN bit together form the software-visible end of the ADC FIFO. SIGN The Sign bit indicates whether the - input has a voltage greater than the + input (differential mode only). For example if ADCGCR.MUX_CFG is 000b, ADC0 is the + input and ADC1 is the - input. If the voltage on ADC0 is greater than the voltage on ADC1, the SIGN bit will be 0; if the voltage on ADC0 is less than the voltage on ADC1, the SIGN bit will be 1. In single-ended mode, this bit always reads as 0. 0 – In differential mode, + input has a voltage greater than the - input. In single-ended mode, this bit is always 0. 1 – In differential mode, - input has a voltage greater than the + input. PEN_DOWN The Pen-Down bit indicates whether a pendown condition is being sensed. To enable pen-down detection, the TOUCH_CFG field of the ADCGCR register must be loaded with 101b. When pen-down detection is enabled and a pen-down condition is sensed, the PEN_DOWN bit is set. This bit is not carried through the FIFO, so its value represents the current status of the pen-down detector. When pen-down detection is enabled, the signal from the pen-down detector is ORed with the Done signal to generate the wake-up signal (WUI30) passed to the MIWU unit. If pendown detection is not enabled, this bit reads as 0. 0 – No pen-down condition is sensed, or pendown detection is disabled. 1 – Pen-down condition is sensed. ADC_OFLW The ADC FIFO Overflow bit indicates whether the 4-word FIFO behind the ADCRESLT register has overflowed. When this occurs, the most recent conversion result is lost. This bit is cleared when the ADCRESLT register is read. 0 – FIFO overflow has not occurred. 1 – FIFO overflow has occurred. ADC_DONE The ADC Done bit indicates when an ADC conversion has completed. When this bit is set, the data in the ADC_RESULT field is valid. When this bit is clear, there is no valid data in the ADC_RESULT field. The Done bit is cleared when the ADCRESLT register is read, but if there are queued conversion results in the FIFO, the Done bit will become set again after one System Clock period. 0 – No ADC conversion has completed since the ADCRESLT register was last read. 1 – An ADC conversion has completed since the ADCRESLT register was last read. 79 www.national.com CP3CN23 15.5.6 CP3CN23 16.0 Random Number Generator (RNG) The RNG unit is a hardware “true random” number generator. When enabled, this unit provides up to 800 random bits per second. The bits are available for reading from a 16-bit register. The RNG unit includes two oscillators which operate independently of the System Clock: When a new 16-bit word of random data is available, it is loaded into the RNGD register. If enabled, an interrupt request (IRQ3) is asserted when the word is available for reading. When software reads the RNGD register, the register is cleared and the interrupt request is deasserted. The RNGCST register provides control and status bits for Fast Oscillator—a 24 MHz oscillator which drives a lin- the RNG module: ear feedback shift register (LFSR). RNG Enable—enables or disables the RNG oscillators. Slow Oscillator—an unstable oscillator which drives a Interrupt Mask—enables or disables the interrupt when flip-flop for sampling the pseudorandom bitstream from a new word of random data becomes available. the LFSR. This oscillator operates at approximately 115 Data Valid—indicates whether a new word is available. kHz, but it does not have a fixed frequency. By sampling the pseudorandom bitstream at random intervals, a random bitstream is synthesized. This bitstream is clocked into a 16-bit shift register. A programmable clock divider generates the clock signal for the shift register from the System Clock. 16.1 FREEZE The RNG module provides support for an In-System Emulator by means of a special FREEZE input. When FREEZE is asserted, the automatic clear-on-read function of the RNDGD register is disabled. RNGCST D Q Enable Q Sample Flip-Flop Clock 31-Bit LFSR Fast Osc. (~24 MHz) Clock Slow Osc. (~115 kHz) (Unstable) D 16-Bit Shift Register Clock RNGD System Bus RNGDIVH/RNGDIVL System Clock Sample Strobe Divider DS185 Figure 15. RNG Module Block Diagram www.national.com 80 RANDOM NUMBER GENERATOR REGISTER SET 16.2.2 The RNGD register holds random data generated by the RNG module. After reading the register, it is cleared and the DVALID bit of the RNGCST register is cleared. When a new word of valid (random) data becomes available in the RNGD register, the DVALID bit is set and (if enabled) and interrupt request is asserted. Table 31 lists the RNG registers. Table 34 RNG Registers Name Address Description RNGCST FF F280h RNG Control and Status Register RNGD FF F282h RNG Data Register RNGDIVH FF F284h RNG Divisor Register High RNGDIVL 16.2.1 FF F286h 15 16.2.3 Reserved IMASK RNG Divisor Register High (RNGDIVH) This register holds the two most significant bits of the RNGDIV clock divisor. See the description of the RNGDIVL register. RNG Divisor Register Low RNG Control and Status Register (RNGCST) 15 DVALID 0 RNGD15:0 15 The RNGCST register provides control and status bits for the RNG module. This register is cleared at reset. RNGE RNG Data Register (RNGD) 6 5 IMSK 4 2 Reserved 1 0 Reserved 16.2.4 DVALID RNGE 2 1 0 RNGDIV17:16 RNG Divisor Register Low (RNGDIVL) This register holds the 16 least significant bits the RNGDIV clock divisor. The Random Number Generator Enable bit enables the operation of the RNG. When this bit is clear, the RNG module is disabled, and both RNG oscillators are suspended. 0 – RNG module disabled. 1 – RNG module enabled. The Data Valid bit indicates whether valid (random) data is available in the RNGD register. This bit is cleared when the RNGD register is read. 0 – RNGD register holds invalid data. 1 – RNGD register holds valid data. The Interrupt Mask bit controls whether an interrupt request (IRQ3) will be asserted when valid (random) data is available in the RNGD register. 0 – RNG interrupt disabled. 1 – RNG interrupt enabled. 15 0 RNGDIV15:0 The RNGDIV clock divisor is used to generate the sampling strobe for loading random bits into the shift register. The divisor is applied to the System Clock source. The maximum frequency after division is 800 Hz. For example, a System Clock frequency of 24 MHz would require an RNGDIV value of 30,000 (7530h) or greater. The default RNGDIV value is 0000 83D6h. 81 www.national.com CP3CN23 16.2 CP3CN23 17.0 CAN Module Each of the two CAN modules provides a Full CAN class, CAN (Controller Area Network) serial bus interface for low/ high speed applications. They support reception and transmission of extended frames with a 29-bit identifier, standard frames with an 11-bit identifier, applications that require high speed (up to 1 MBit/s), and a low-speed CAN interface with CAN master capability. Data transfer between the CAN bus and the CPU is handled by 15 message buffers, which can be individually configured as receive or transmit buffers. Every message buffer includes a status/control register which provides information about its current status and capabilities to configure the buffer. All message buffers are able to generate an interrupt on the reception of a valid frame or the successful transmission of a frame. In addition, an interrupt can be generated on bus errors. An incoming message is only accepted if the message identifier passes one of two acceptance filtering masks. The filtering mask can be configured to receive a single message ID for each buffer or a group of IDs for each receive buffer. One of the buffers uses a separate message filtering procedure. This provides the capability to establish a BASIC-CAN path. Remote transmission requests can be processed automatically by automatic reconfiguration to a receiver after transmission or by automated transmit scheduling upon reception. A priority decoder allows any buffer to have one of 16 transmit priorities including the highest or lowest absolute priority, for a total of 240 different transmit priorities. A decided bit time counter (16-bit wide) is provided to support real time applications. The contents of this counter are captured into the message buffer RAM on reception or transmission. The counter can be synchronized through the CAN network. This synchronization feature allows a reset of the counter after the reception or transmission of a message in buffer 0. Each CAN module is a fast CPU bus peripheral which allows single-cycle byte or word read/write access. The CPU controls the CAN module by programming the registers in the CAN register block. This includes initialization of the CAN baud rate, logic level of the CAN pins, and enable/disable of the CAN module. A set of diagnostic features, such as loopback, listen only, and error identification, support development with the CAN module and provide a sophisticated error management tool. Each CAN module implements the following features: CAN specification 2.0B — Standard data and remote frames — Extended data and remote frames — 0 to 8 bytes data length — Programmable bit rate up to 1 Mbit/s 15 message buffers, each configurable as receive or transmit buffers — Message buffers are 16-bit wide dual-port RAM — One buffer may be used as a BASIC-CAN path Remote Frame support — Automatic transmission after reception of a Remote Transmission Request (RTR) — Auto receive after transmission of a RTR Acceptance filtering www.national.com 82 — Two filtering capabilities: global acceptance mask and individual buffer identifiers — One of the buffers uses an independent acceptance filtering procedure Programmable transmit priority Interrupt capability — One interrupt vector for all message buffers (receive/ transmit/error) — Each interrupt source can be enabled/disabled 16-bit counter with time stamp capability on successful reception or transmission of a message Power Save capabilities with programmable Wake-Up over the CAN bus (alternate source for the Multi-Input Wake-Up module) Push-pull capability of the input/output pins Diagnostic functions — Error identification — Loopback and listen-only features for test and initialization purposes 17.1 FUNCTIONAL DESCRIPTION As shown in Figure 16, each CAN module consists of three blocks: the CAN core, interface management, and a dualported RAM containing the message buffers. There are two dedicated device pins for each CAN interface, CANnTX as the transmit output and CANnRX as the receive input. The CAN core implements the basic CAN protocol features such as bit-stuffing, CRC calculation/checking, and error management. It controls the transceiver logic and creates error signals according to the bus rules. In addition, it converts the data stream from the CPU (parallel data) to the serial CAN bus data. The interface management block is divided into the register block and the interface management processor. The register block provides the CAN interface with control information from the CPU and provides the CPU with status information from the CAN module. Additionally, it generates the interrupt to the CPU. The interface management processor is a state machine executing the CPU’s transmission and reception commands and controlling the data transfer between several message buffers and the RX/TX shift registers. 15 message buffers are memory mapped into RAM to transmit and receive data through the CAN bus. Eight 16-bit registers belong to each buffer. One of the registers contains control and status information about the message buffer configuration and the current state of the buffer. The other registers are used for the message identifier, a maximum of up to eight data bytes, and the time stamp information. During the receive process, the incoming message will be stored in a hidden receive buffer until the message is valid. Then, the buffer contents will be copied into the first message buffer which accepts the ID of the received message. CP3CN23 CANnTX CANnRX Wake-Up CTX 0 0 1 1 CRX CAN CORE Transceiver Logic BTL, RX shift, TX shift, CRC Bit Stream Processor Control Error Management Logic Status INTERFACE MANAGEMENT Data Control Interface Management Processor RAM TX/RX Message Buffer 0 Acceptance Filtering TX/RX Message Buffer 1 Interface Management Processor BTL CONFIG CAN PRESCALER CONTROL TX/RX Message Buffer 14 ACCEPTANCE MASKS CPU BUS DS281 Figure 16. CAN Block Diagram A CAN master module has the ability to set a specific bit called the “remote data request bit” (RTR) in a frame. Such This section provides a generic overview of the basic cona message is also called a “Remote Frame”. It causes ancepts of the Controller Area Network (CAN). other module, either another master or a slave which acThe CAN protocol is a message-based protocol that allows cepts this remote frame, to transmit a data frame after the a total of 2032 (211 - 16) different messages in the standard remote frame has been completed. format and 512 million (229 - 16) different messages in the Additional modules can be added to an existing network extended frame format. without a configuration change. These modules can either Every CAN Frame is broadcast on the common bus. Each perform completely new functions requiring new data, or module receives every frame and filters out the frames process existing data to perform a new functionality. which are not required for the module's task. For example, As the CAN network is message oriented, a message can if a dashboard sends a request to switch on headlights, the be used as a variable which is automatically updated by the CAN module responsible for brake lights must not process controlling processor. If any module cannot process inforthis message. mation, it can send an overload frame. 17.2 BASIC CAN CONCEPTS 83 www.national.com CP3CN23 The CAN protocol allows several transmitting modules to start a transmission at the same time as soon as they detect the bus is idle. During the start of transmission, every node monitors the bus line to detect whether its message is over- written by a message with a higher priority. As soon as a transmitting module detects another module with a higher priority accessing the bus, it stops transmitting its own frame and switches to receive mode, as shown in Figure 17. TxPIN MODULE A RxPIN TxPIN MODULE B RxPIN BUS LINE RECESSIVE DOMINANT MODULE A SUSPENDS TRANSMISSION DS019 Figure 17. CAN Message Arbitration If a data or remote frame loses arbitration on the bus due to a higher-prioritized data or remote frame, or if it is destroyed by an error frame, the transmitting module will automatically retransmit it until the transmission is successful or software has canceled the transmit request. 17.2.2 Communication via the CAN bus is basically established by means of four different frame types: Start of Frame (SOF) If a transmitted message loses arbitration, the CAN module will restart transmission at the next possible time with the message which has the highest internal transmit priority. 17.2.1 CAN Frame Types Data Frame Remote Frame Error Frame Overload Frame Data and remote frames can be used in both standard and extended frame format. If no message is being transmitted, i.e., the bus is idle, the bus is kept at the “recessive” level. Remote and data frames are non-return to zero (NRZ) coded with bit-stuffing in every bit field, which holds computable information for the interface, i.e., start of frame, arbitration field, control field, data field (if present), and CRC field. Error and overload frames are also NRZ coded, but without bit-stuffing. After five consecutive bits of the same value (including inserted stuff bits), a stuff bit of the inverted value is inserted into the bit stream by the transmitter and deleted by the receiver. The following shows the stuffed and destuffed bit stream for consecutive ones and zeros. Original or 10000011111 . . . unstuffed bit stream Stuffed bit stream (stuff bits in bold) www.national.com CAN Frame Fields Data and remote frames consist of the following bit fields: Start of Frame (SOF) Arbitration Field Control Field Data Field CRC Field ACK Field EOF Field The Start of Frame (SOF) indicates the beginning of data and remote frames. It consists of a single “dominant” bit. A node is only allowed to start transmission when the bus is idle. All nodes have to synchronize to the leading edge (first edge after the bus was idle) caused by the SOF of the node which starts transmission first. Arbitration Field The Arbitration field consists of the identifier field and the RTR (Remote Transmission Request) bit. For extended frames there is also a SRR (Substitute Remote Request) and a IDE (ID Extension) bit inserted between ID18 and ID17 of the identifier field. The value of the RTR bit is “dominant” in a data frame and “recessive” in a remote frame. Control Field The Control field consists of six bits. For standard frames it starts with the ID Extension bit (IDE) and a reserved bit (RB0). For extended frames, the control field starts with two reserved bits (RB1, RB0). These bits are followed by the 4bit Data Length Code (DLC). The CAN receiver accepts all possible combinations of the reserved bits (RB1, RB0). The transmitter must be configured to send only zeros. 01111100000 . . . 1000001111101 . . . 0111110000010 . . . 84 The remainder of this division is the CRC sequence transmitted over the bus. On the receiver side, the module divides all bit fields up to the CRC delimiter excluding stuff bits, and checks if the result is zero. This will then be interpreted as a valid CRC. After the CRC sequence a single “recessive” bit is transmitted as the CRC delimiter. The DLC field indicates the number of bytes in the data field. It consists of four bits. The data field can be of length zero. The admissible number of data bytes for a data frame ranges from 0 to 8. Data Field ACK Field The Data field consists of the data to be transferred within a data frame. It can contain 0 to 8 bytes. A remote frame has The ACK field is two bits long and contains the ACK slot and the ACK delimiter. The ACK slot is filled with a “recessive” no data field. bit by the transmitter. This bit is overwritten with a “domiCyclic Redundancy Check (CRC) nant” bit by every receiver that has received a correct CRC The CRC field consists of the CRC sequence followed by sequence. The second bit of the ACK field is a “recessive” the CRC delimiter. The CRC sequence is derived by the bit called the acknowledge delimiter. transmitter from the modulo 2 division of the preceding bit fields, starting with the SOF up to the end of the data field, excluding stuff-bits, by the generator polynomial: The End of Frame field closes a data and a remote frame. It consists of seven “recessive” bits. 17.2.3 x15 + x14 + x10 + x8 + x7 + x4 + x3 + 1 CAN Frame Formats Data Frame The structure of a standard data frame is shown in Figure 18. The structure of an extended data frame is shown in Figure 19. 16 Control Field 11 Data Field d CRC Field 8 4 8 15 CRC DLC ID0 RTR IDE RB0 DLC3 START OF FRAME ID 10 8N (0 < N < 8) Arbitration Field CRC DEL ACKNOWLEDGEMENT ACK DEL STANDARD DATA FRAME (number of bits = 44 + 8N) d d d IDENTIFIER 10 ... 0 r END OF FRAME r r r r r r r r DATA LENGTH CODE Bit Stuffing DS020 Note: d = dominant r = recessive Figure 18. Standard Data Frame 18 IDENTIFIER 28 ... 18 16 Data Field CRC Field ID0 RTR RB1 RB0 DLC3 r r d d d IDENTIFIER 17 ... 0 8 4 ID18 SRR IDE ID17 11 d 8N (0 < N < 0) Control Field 8 15 CRC END OF FRAME CRC DEL SCK ACK DEL Arbitration Field DLC START OF FRAME ID 28 EXTENDED DATA FRAME (number of bits = 64 + 8N) r r r r r r r r r DATA LENGTH CODE Bit Stuffing Note: d = dominant r = recessive DS021 Figure 19. Extended Data Frame 85 www.national.com CP3CN23 Data Length Code (DLC) Start of Frame (SOF) Arbitration Field + Extended Arbitration Control Field Data Field Cyclic Redundancy Check Field (CRC) Remote Frame Figure 20 shows the structure of a standard remote frame. Figure 21 shows the structure of an extended remote frame. Control Field 11 CRC Field d 15 CRC DLC0 ID0 RTR IDE RB0 DLC3 4 ID3 START OF FRAME ID 10 16 Arbitration Field d d d IDENTIFIER 10 ... 0 CRC DEL ACKNOWLEDGEMENT ACK DEL STANDARD REMOTE FRAME (number of bits = 44) r END OF FRAME r r r r r r r r DATA LENGTH CODE Note: d = dominant r = recessive DS022 Figure 20. Standard Remote Frame EXTENDED REMOTE FRAME (number of bits = 64) 16 Control Field 11 IDENTIFIER 28 ... 18 ID18 SRR IDE ID17 ID0 RTR RB1 RB0 DLC3 d 4 18 r r r d d IDENTIFIER 17 ... 0 15 r r r r r r r r r DS023 Figure 21. Extended Remote Frame A remote frame is comprised of the following fields, which is the same as a data frame (see CAN Frame Fields on page 84) except for the data field, which is not present. Start of Frame (SOF) Arbitration Field + Extended Arbitration Control Field Cyclic Redundancy Check Field (CRC) Acknowledgment field (ACK) End of Frame (EOF) Note that the DLC must have the same value as the corresponding data frame to prevent contention on the bus. The RTR bit is “recessive”. www.national.com CRC END OF FRAME DATA LENGTH CODE Note: d = dominant r = recessive CRC Field CRC DEL SCK ACK DEL Arbitration Field DLC0 START OF FRAME ID 28 CP3CN23 Acknowledgment Field (ACK) End of Frame (EOF) A CAN data frame consists of the following fields: 86 at the bit following the acknowledge delimiter, unless an erAs shown in Figure 22, the Error Frame consists of the error ror flag for a previous error condition has already been startflag and the error delimiter bit fields. The error flag field is ed. built up from the various error flags of the different nodes. If a device is in the error active state, it can send a “domiTherefore, its length may vary from a minimum of six bits up nant” error flag, while a error passive device is only allowed to a maximum of twelve bits depending on when a module to transmit “recessive” error flags. This is done to prevent has detected the error. Whenever a bit error, stuff error, form the CAN bus from getting stuck due to a local defect. For the error, or acknowledgment error is detected by a node, the various CAN device states, please refer to Error Types on node starts transmission of an error flag at the next bit. If a page 88. CRC error is detected, transmission of the error flag starts ERROR FRAME DATA FRAME OR REMOVE FRAME 6 <6 8 ERROR FLAG ECHO ERROR FLAG ERROR DELIMITER d d d d d d d Note: d = dominant r = recessive d d r r r r r r INTER-FRAME OR OVERLOAD FRAME r r d An error frame can start anywhere within a frame DS024 Figure 22. Error Frame Overload Frame overload condition and start the transmission of an overload flag. After an overload flag has been transmitted, the overload frame is closed by the overload delimiter. As shown in Figure 23, an overload frame consists of the overload flag and the overload delimiter bit fields. The bit fields have the same length as the error frame field: six bits for the overload flag and eight bits for the delimiter. The overload frame can only be sent after the end of frame (EOF) field and in this way destroys the fixed form of the intermission field. As a result, all other nodes also detect an Note: The CAN module never initiates an overload frame due to its inability to process an incoming message. However, it is able to recognize and respond to overload frames initiated by other devices. OVERLOAD FRAME END OF FRAME OR ERROR DELIMITER OR OVERLOAD DELIMITER Note: d = dominant r = recessive 6 8 OVERLOAD FLAG OVERLOAD DELIMITER d d d d d d d r r r r r r INTER-FRAME SPACE OR ERROR FRAME r r An overload frame can only start at the end of a frame DS025 Figure 23. Overload Frame Interframe Space Data and remote frames are separated from every preceding frame (data, remote, error and overload frames) by the interframe space (see Figure 24). Error and overload frames are not preceded by an interframe space; they can be transmitted as soon as the condition occurs. The interframe space consists of a minimum of three bit fields depending on the error state of the node. 87 www.national.com CP3CN23 Error Frame CP3CN23 INTERFRAME SPACE 3 START OF FRAME 8 SUSPEND TRANSMIT INT Bus Idle ANY FRAME r r r r r r r r r r r r r r r r r r r r r DATA FRAME OR REMOTE FRAME r d Note: d = dominant r = recessive INT = Intermission Suspend Transmission is only for error passive nodes. DS026 Figure 24. Interframe Space 17.2.4 Error Types a receiver, a “dominant” bit during the last bit of End of Frame does not constitute a frame error. Bit Error Bit CRC Error A CAN device which is currently transmitting also monitors the bus. If the monitored bit value is different from the transmitted bit value, a bit error is detected. However, the reception of a “dominant” bit instead of a “recessive” bit during the transmission of a passive error flag, during the stuffed bit stream of the arbitration field, or during the acknowledge slot is not interpreted as a bit error. A CRC error is detected if the remainder from the CRC calculation of a received CRC polynomial is non-zero. Acknowledgment Error An acknowledgment error is detected whenever a transmitting node does not get an acknowledgment from any other node (i.e., when the transmitter does not receive a “dominant” bit during the ACK frame). Stuff Error A stuff error is detected if 6 consecutive bits occur without a Error States state change in a message field encoded with bit stuffing. The device can be in one of five states with respect to error Form Error handling (see Figure 25). A form error is detected, if a fixed frame bit (e.g., CRC delimiter, ACK delimiter) does not have the specified value. For External Reset or Enable CR16CAN SYNC 11 consecutive 'recessive" bits received (TEC OR REC) > 95 ERROR ACTIVE (TEC AND REC) < 96 (TEC OR REC) > 127 ERROR WARNING (TEC AND REC) < 128 ERROR PASSIVE TEC > 255 128 occurrences of 11 consecutive 'recessive" bits BUS OFF DS027 Figure 25. Bus States Synchronize the bus communication. This state must also be entered after waking-up the device using the Multi-Input Wake-Up feaOnce the CAN module is enabled, it waits for 11 consecuture. See System Start-Up and Multi-Input Wake-Up on tive recessive bits to synchronize with the bus. After that, the CAN module becomes error active and can participate in page 113. www.national.com 88 when the transmit error counter is greater than 255. A bus An error active unit can participate in bus communication off device will become error active again after monitoring 128 × 11 “recessive” bits (including bus idle) on the bus. and may send an active (“dominant”) error flag. When the device goes from “bus off“ to “error active“, both Error Warning error counters will have a value of 0. The Error Warning state is a sub-state of Error Active to indicate a heavily disturbed bus. The CAN module behaves as in Error Active mode. The device is reset into the Error Active mode if the value of both counters is less than 96. 17.2.5 Bus Off The Error counters can be read by application software as described under CAN Error Counter Register (CANECn) on page 112. Error Counters There are multiple mechanisms in the CAN protocol to detect errors and inhibit erroneous modules from disabling all bus activities. Each CAN module includes two error Error Passive counters to perform error management. The receive error An error passive unit can participate in bus communication. counter (REC) and the transmit error counter (TEC) are 8However, if the unit detects an error it is not allowed to send bits wide, located in the 16-bit wide CANEC register. The an active error flag. The unit sends only a passive (“reces- counters are modified by the CAN module according to the sive”) error flag. A device is error passive when the transmit rules listed in Table 35. This table provides an overview of error counter or the receive error counter is greater than the CAN error conditions and the behavior of the CAN mod127. A device becoming error passive will send an active er- ule; for a detailed description of the error management and ror flag. An error passive device becomes error active again fault confinement rules, refer to the CAN Specification 2.0B. when both transmit and receive error counter are less than If the MSB (bit 7) of the REC is set, the node is error passive 128. and the REC will not increment any further. A unit that is bus off has the output drivers disabled, i.e., it does not participate in any bus activity. A device is bus off Table 35 Error Counter Handling Condition Action Receive Error Counter Conditions A receiver detects a bit error during sending an active error flag. Increment by 8 A receiver detects a “dominant“ bit as the first bit after sending an error flag Increment by 8 After detecting the 14th consecutive “dominant“ bit following an active error flag or overload flag, or after detecting the 8th consecutive “dominant“ bit following a passive error flag. After each sequence of additional 8 consecutive “dominant” bits. Increment by 8 Any other error condition (stuff, frame, CRC, ACK) Increment by 1 A valid reception or transmission Decrement by 1 unless counter is already 0 Transmit Error Counter Conditions A transmitter detects a bit error while sending an active error flag Increment by 8 After detecting the 14th consecutive “dominant“ bit following an active error flag or overload flag or after detecting the 8th consecutive “dominant“ bit following a passive error flag. After each sequence of additional 8 consecutive ‘dominant’ bits. Increment by 8 Any other error condition (stuff, frame, CRC, ACK) Increment by 8 A valid reception or transmission Decrement by 1 unless counter is already 0 Special error handling for the TEC counter is performed in If only one device is on the bus and this device transmits the following situations: a message, it will get no acknowledgment. This will be detected as an error and the message will be repeated. A stuff error occurs during arbitration, when a transmitted When the device goes “error passive” and detects an ac“recessive” stuff bit is received as a “dominant” bit. This knowledge error, the TEC counter is not incremented. does not lead to an increment of the TEC. Therefore the device will not go from ”error passive” to An ACK-error occurs in an error passive device and no the “bus off” state due to such a condition. “dominant” bits are detected while sending the passive error flag. This does not lead to an increment of the TEC. 89 www.national.com CP3CN23 Error Active CP3CN23 17.2.6 Bit Time Logic CAN Bit Time In the Bit Time Logic (BTL), the CAN bus speed and the Synchronization Jump Width can be configured by software. The CAN module divides a nominal bit time into three time segments: synchronization segment, time segment 1 (TSEG1), and time segment 2 (TSEG2). Figure 26 shows the various elements of a CAN bit time. The number of time quanta in a CAN bit (CAN Bit Time) ranges between 4 and 25. The sample point is positioned between TSEG1 and TSEG2 and the transmission point is positioned at the end of TSEG2. INTERNAL TIME QUANTA CLOCK ONE TIME QUANTUM 4 to 25 TIme Quanta A TIME SEGMENT 1 (TSEG1) TIME SEGMENT 1 (TSEG1) 16 TIme Quanta 2 to 16 Time Quanta 1 to 8 Time Quanta SAMPLE POINT A = synchronization segment (Sync) TRANSMISSION POINT DS028 Figure 26. Bit Timing TSEG1 includes the propagation segment and the phase segment 1 as specified in the CAN specification 2.0B. The length of the time segment 1 in time quanta (tq) is defined by the TSEG1[3:0] bits. TSEG2 represents the phase segment 2 as specified in the CAN specification 2.0B. The length of time segment 2 in time quanta (tq) is defined by the TSEG2[3:0] bits. The Synchronization Jump Width (SJW) defines the maximum number of time quanta (tq) by which a received CAN bit can be shortened or lengthened in order to achieve resynchronization on “recessive” to “dominant” data transitions on the bus. In the CAN implementation, the SJW must be configured less or equal to TSEG1 or TSEG2, whichever is smaller. Synchronization A CAN device expects the transition of the data signal to be within the synchronization segment of each CAN bit time. This segment has the fixed length of one time quantum. However, two CAN nodes never operate at exactly the same clock rate, and the bus signal may deviate from the ideal waveform due to the physical conditions of the network (bus length and load). To compensate for the various delays within a network, the sample point can be positioned by programming the length of TSEG1 and TSEG2 (see Figure 26). In addition, two types of synchronization are supported. The BTL logic compares the incoming edge of a CAN bit with the internal bit timing. The internal bit timing can be adapted by either hard or soft synchronization (re-synchronization). Hard synchronization is performed at the beginning of a new frame with the falling edge on the bus while the bus is idle. This is interpreted as the SOF. It restarts the internal logic. Soft synchronization is performed during the reception of a bit stream to lengthen or shorten the internal bit time. Dewww.national.com 90 pending on the phase error (e), TSEG1 may be increased or TSEG2 may be decreased by a specific value, the resynchronization jump width (SJW). The phase error is given by the deviation of the edge to the SYNC segment, measured in CAN clocks. The value of the phase error is defined as: e = 0, if the edge occurs within the SYNC segment e > 0, if the edge occurs within TSEG1 e < 0, if the edge occurs within TSEG2 of the previous bit Resynchronization is performed according to the following rules: If the magnitude of e is less then or equal to the programmed value of SJW, resynchronization will have the same effect as hard synchronization. If e > SJW, TSEG1 will be lengthened by the value of the SJW (see Figure 27). If e < -SJW, TSEG2 will be shortened by the value SJW (see Figure 28). CP3CN23 e Bus Signal CAN Clock PREVIOUS BIT A TSEG1 TSEG2 NEXT BIT "NORMAL" BIT TIME PREVIOUS BIT A TSEG1 SJW TSEG2 NEXT BIT BIT TIME LENGTHENED BY SJW DS029 Figure 27. Resynchronization (e > SJW) e Bus Signal CAN Clock PREVIOUS BIT A TSEG1 TSEG2 "NORMAL" BIT TIME PREVIOUS BIT A TSEG1 TSEG2 NEXT BIT BIT TIME SHORTENED BY SJW DS030 Figure 28. 17.2.7 Resynchronization (e < -SJW) Clock Generator PSC = PSC[5:0] + 2 TSEG1 = TSEG1[3:0] + 1 TSEG2 = TSEG2[2:0] + 1 The CAN prescaler (PSC) is shown is Figure 29. It divides the CKI input clock by the value defined in the CTIM register. The resulting clock is called time quanta clock and defines the length of one time quantum (tq). CKI Please refer to CAN Timing Register (CTIM) on page 108 for a detailed description of the CTIM register. ÷ (1+TSEG1+TSEG2) Bit Rate Internal Time Quanta Clock (1/tq) Note: PSC is the value of the clock prescaler. TSEG1 and TSEG2 are the length of time segment 1 and 2 in time quanta. The resulting bus clock can be calculated by the equation: ÷ PSC DS031 Figure 29. CAN Prescaler 17.3 MESSAGE TRANSFER The CAN module has access to 15 independent message buffers, which are memory mapped in RAM. Each message buffer consists of 8 different 16-bit RAM locations and can The values of PSC, TSEG1, and TSEG2 are specified by be individually configured as a receive message buffer or as the contents of the registers PSC, TSEG1, and TSEG2 as a transmit message buffer. follows: A dedicated acceptance filtering procedure enables softCKI busclock = ------------------------------------------------------------------------------------( PSC )x ( 1 + TSEG1 + TSEG2 ) ware to configure each buffer to receive only a single message ID or a group of messages. One buffer uses an 91 www.national.com CP3CN23 independent filtering procedure, which provides the possibility to establish a BASIC-CAN path. For reception of data frame or remote frames, the CAN module follows a “receive on first match” rule which means that a given message is only received by one buffer: the first one which matches the received message ID. This provides the capability to accept only a single ID for each buffer or to accept a group of IDs. The following two examples illustrate the difference. Example 1: Acceptance of a Single Identifier If the global mask is loaded with 00h, the acceptance filtering of an incoming message is only determined by the indiThe transmission of a frame can be initiated by software vidual buffer ID. This means that only one message ID is writing to the transmit status and priority register. An alter- accepted for each buffer. nate way to schedule a transmission is the automatic answer to remote frames. In the latter case, the CAN module GMASK1 GMASK2 00000000 00000000 00000000 00000 will schedule every buffer for transmission to respond to remote frames with a given identifier if the acceptance mask matches. This implies that a single remote frame is able to BUFFER_ID1 BUFFER_ID2 10101010 10101010 10101010 10101 poll multiple matching buffers configured to respond to the triggering remote transmission request. 17.4 ACCEPTANCE FILTERING Accepted ID Two 32-bit masks are used to filter unwanted messages from the CAN bus: GMASK and BMASK. Figure 30 shows the mask and the buffers controlled by the masks. 10101010 10101010 10101 DS033 Figure 31. Buffer 0 10101010 Acceptance of a Single Identifier Example 2: Reception of an Identifier Group BUFFER_ID Set bits in the global mask register change the corresponding bit status within the buffer ID to “don’t care” (X). Messages which match the non-“don’t care” bits (the bits corresponding to clear bits in the global mask register) are accepted. GMASK1 GMASK2 Buffer 13 BUFFER_ID GMASK1 00000000 11111111 GMASK2 00000000 00000 BUFFER_ID1 10101010 10101010 BUFFER_ID2 10101010 10101 Buffer 14 BMASK1 BMASK2 BUFFER_ID Accepted ID Group 10101010 XXXXXXXX 10101010 10101 DS034 DS032 Figure 32. Acceptance of a Group of Identifiers Figure 30. Acceptance Filtering Acceptance filtering of the incoming messages for the buffers 0...13 is performed by means of a global filtering mask (GMASK) and by the buffer ID of each buffer. Acceptance filtering of incoming messages for buffer 14 is performed by a separate filtering mask (BMASK) and by the buffer ID of that buffer. Once a received object is waiting in the hidden buffer to be copied into a buffer, the CAN module scans all buffers configured as receive buffers for a matching filtering mask. The buffers 0 to 13 are checked in ascending order beginning with buffer 0. The contents of the hidden buffer are copied into the first buffer with a matching filtering mask. A separate filtering path is used for buffer 14. For this buffer, acceptance filtering is established by the buffer ID in conjunction with the basic filtering mask. This basic mask uses the same method as the global mask (set bits correspond to “don’t care” bits in the buffer ID). Therefore, the basic mask allows a large number of infrequent messages to be received by this buffer. Note: If the BMASK register is equal to the GMASK register, the buffer 14 can be used the same way as the buffers 0 to 13. The buffers 0 to 13 are scanned prior to buffer 14. Subsequently, the buffer 14 will not be checked for a matching ID when one of the buffers 0 to 13 has already received an object. Bits holding a 1 in the global filtering mask (GMASK) can be represented as a “don’t care” of the associated bit of each By setting the BUFFLOCK bit in the configuration register, buffer identifier, regardless of whether the buffer identifier bit the receiving buffer is automatically locked after reception of is 1 or 0. one valid frame. The buffer will be unlocked again after the CPU has read the data and has written RX_READY in the www.national.com 92 As shown in Figure 33, several messages with the same ID are received while BUFFLOCK is enabled. The filtering mask of the buffers 0, 1, 13, and 14 is set to accept this message. The first incoming frame will be received by buffer 0. Because buffer 0 is now locked, the next frame will be received by buffer 1, and so on. If all matching receive buffers are full and locked, a further incoming message will not be received by any buffer. Received ID 01010 10101010 10101010 10101010 GMASK 00000 11111111 00000000 00000000 BUFFER0_ID 01010 XXXXXXXX 10101010 10101010 Saved when buffer is empty BUFFER1_ID 01010 XXXXXXXX 10101010 10101010 Saved when buffer is empty BUFFER13_ID 01010 XXXXXXXX 10101010 10101010 Saved when buffer is empty BMASK 00000 11111111 00000000 00000000 BUFFER14_ID 01010 XXXXXXXX 10101010 10101010 Saved when buffer is empty DS035 Figure 33. 17.5 Message Storage with BUFFLOCK Enabled RECEIVE STRUCTURE All received frames are initially buffered in a hidden receive buffer until the frame is valid. (The validation point for a received message is the next-to-last bit of the EOF.) The received identifier is then compared to every buffer ID together with the respective mask and the status. As soon as the validation point is reached, the whole contents of the hidden buffer are copied into the matching message buffer as shown in Figure 34. Note: The hidden receive buffer must not be accessed by the CPU. Buffer 0 BUFFER_ID Buffer 13 CR16CAN Hidden Receive Buffer BUFFER_ID Buffer 14 BUFFER_ID DS036 Figure 34. Receive Buffer The following section gives an overview of the reception of the different types of frames. The received data frame is stored in the first matching receive buffer beginning with buffer 0. For example, if the message is accepted by buffer 5, then at the time the message will be copied, the RX request is cleared and the CAN module will not try to match the frame to any subsequent buffer. 93 www.national.com CP3CN23 buffer status field. With this lock function, software has the capability to save several messages with the same identifier or same identifier group into more than one buffer. For example, a buffer with the second highest priority will receive a message if the buffer with the highest priority has already received a message and is now locked (provided that both buffers use the same acceptance filtering mask). CP3CN23 All contents of the hidden receive buffer are always copied into the respective receive buffer. This includes the received message ID as well as the received Data Length Code (DLC); therefore when some mask bits are set to don’t care, the ID field will get the received message ID which could be different from the previous ID. The DLC of the receiving buffer will be updated by the DLC of the received frame. The DLC of the received message is not compared with the DLC already present in the CNSTAT register of the message buffer. This implies that the DLC code of the CNSTAT register indicates how may data bytes actually belong to the latest received message. Data Frames. In the second method, a remote frame can trigger one or more message buffer to transmit a data frame upon reception. This procedure is described under To Answer Remote Frames on page 96. 17.5.1 Receive Timing As soon as the CAN module receives a “dominant” bit on the CAN bus, the receive process is started. The received ID and data will be stored in the hidden receive buffer if the global or basic acceptance filtering matches. After the reception of the data, CAN module tries to match the buffer ID of buffer 0...14. The data will be copied into the buffer after the reception of the 6th EOF bit as a message is valid at this The remote frames are handled by the CAN interface in two time. The copy process of every frame, regardless of the different ways. In the first method, remote frames can be relength, takes at least 17 CKI cycles (see also CPU Access ceived like data frames by configuring the buffer to be to CAN Registers/Memory on page 100). Figure 35 shows RX_READY and setting the ID bits including the RTR bit. In the receive timing. that case, the same procedure applies as described for BUS IDLE SOF 1 BIT ARBITRATION FIELD + CONTROL 12/29 BIT + 6 BIT CRC FIELD 16 BIT DATA FIELD (IF PRESENT) n × 8 BIT ACK FIELD 2 BIT EOF 7 BIT IFS 3 BIT BUS rx_start Copy to Buffer BUSY DS037 Figure 35. Receive Timing To indicate that a frame is waiting in the hidden buffer, the BUSY bit (ST[0]) of the selected buffer is set during the copy procedure. The BUSY bit will be cleared by the CAN module immediately after the data bytes are copied into the buffer. After the copy process is finished, the CAN module changes the status field to RX_FULL. In turn, the CPU should change the status field to RX_READY when the data is processed. When a new object has been received by the same buffer, before the CPU changed the status to RX_READY, the CAN module will change the status to RX_OVERRUN to indicate that at least one frame has been overwritten by a new one. Table 36 summarizes the current status and the resulting update from the CAN module. Table 36 Writing to Buffer Status Code During RX_BUSY Current Status Resulting Status RX_READY RX_FULL RX_NOT_ACTIVE RX_NOT_ACTIVE RX_FULL RX_OVERRUN During the assertion of the BUSY bit, all writes to the receiving buffer are disabled with the exception of the status field. If the status is changed while the BUSY bit is asserted, the status is updated by the CAN module as shown in Table 36. The buffer states are indicated and controlled by the ST[3:0] bits in the CNSTAT register (see Buffer Status/Control Regwww.national.com 94 ister (CNSTAT) on page 101). The various receive buffer states are explained in RX Buffer States on page 95. 17.5.2 Receive Procedure Software executes the following procedure to initialize a message buffer for the reception of a CAN message. 1. Configure the receive masks (GMASK or BMASK). 2. Configure the buffer ID. 3. Configure the message buffer status as RX_READY. To read the out of a received message, the CPU must execute the following steps (see Figure 36): 2. Read CNSTAT 3. 4. 5. RX_READY? No 6. Yes RX_BUSYx? 7. No When the BUFFLOCK function is enabled (see BUFFLOCK on page 92), it is not necessary to check for new messages received during the read process from the buffer, as this buffer is locked after the reception of the first valid frame. A read from a locked receive buffer can be performed as shown in Figure 37. Interrupt Entry Point RX_OVERRUN? (optional, for information) Write RX_READY Interrupt Entry Point Read buffer (id/data/control) Read buffer (id/data/control) Read CNSTAT Write RX_READY RX_BUSYx? Clear RX_PND Yes No Exit RX_FULL or RX_OVERRUN? Yes DS039 No Figure 36. Figure 37. Buffer Read Routine (BUFFLOCK Enabled) Clear RX_PND For simplicity only the applicable interrupt routine is shown: Exit 1. Read the ID/data and object control (DLC/RTR) from the message buffer. 2. Write RX_READY into CNSTAT. 3. Clear interrupt pending bit and exit. DS038 Buffer Read Routine (BUFFLOCK Disabled) 17.5.3 RX Buffer States The first step is only applicable if polling is used to get the As shown in Figure 37, a receive procedure starts as soon status of the receive buffer. It can be deleted for an interrupt as software has set the buffer from the RX_NOT_ACTIVE state into the RX_READY state. The status section of CNdriven receive routine. STAT register is set from 0000b to 0010b. When a message 1. Read the status (CNSTAT) of the receive buffer. If the is received, the buffer will be RX_BUSYx during the copy status is RX_READY, no was the message received, so process from the hidden receive buffer into the message exit. If the status is RX_BUSY, the copy process from buffer. Afterwards this buffer is RX_FULL. The CPU can hidden receive buffer is not completed yet, so read CNthen read the buffer data and either reset the buffer status STAT again. to RX_READY or receive a new frame before the CPU reads the buffer. In the second case, the buffer state will automatIf a buffer is configured to RX_READY and its interrupt ically change to RX_OVERRUN to indicate that at least one is enabled, it will generate an interrupt as soon as the message was lost. During the copy process the buffer will buffer has received a message and entered the again be RX_BUSYx for a short time, but in this case the 95 www.national.com CP3CN23 Yes Read buffer RX_FULL state (see also Interrupts on page 98). In that case the procedure described below must be followed. Read the status to determine if a new message has overwritten the one originally received which triggered the interrupt. Write RX_READY into CNSTAT. Read the ID/data and object control (DLC/RTR) from the message buffer. Read the buffer status again and check it is not RX_BUSYx. If it is, repeat this step until RX_BUSYx has gone away. If the buffer status is RX_FULL or RX_OVERRUN, one or more messages were copied. In that case, start over with step 2. If status is still RX_READY (as set by the CPU at step 2), clear interrupt pending bit and exit. CP3CN23 CNSTAT status section will be 0101b, as the buffer was RX_FULL (0100b) before. After finally reading the last received message, the CPU can reset the buffer to RX_READY. tance filtering mask of one or more buffers, the buffer status will change to TX_ONCE_RTR, the contents of the buffer will be transmitted, and afterwards the CAN module will write TX_RTR in the status code register again. If the CPU writes TX_ONCE_RTR into the buffer status, the contents of the buffer will be transmitted, and the successful To transmit a CAN message, software must configure the transmission the buffer goes into the “wait for Remote message buffer by changing the buffer status to Frame” condition TX_RTR. TX_NOT_ACTIVE. The buffer is configured for transmission if the ST[3] bit of the buffer status code (CNSTAT) is set. In 17.6.1 Transmit Scheduling TX_NOT_ACTIVE status, the buffer is ready to receive data After writing TX_ONCE into the buffer status, the transmisfrom the CPU. After receiving all transmission data (ID, data sion process begins and the BUSY bit is set. As soon as a bytes, DLC, and PRI), the CPU can start the transmission buffer gets the TX_BUSY status, the buffer is no longer acby writing TX_ONCE into the buffer status register. During cessible by the CPU except for the ST[3:1] bits of the CNthe transmission, the status of the buffer is TX_BUSYx. Af- STAT register. Starting with the beginning of the CRC field ter successful transmission, the CAN module will reset the of the current frame, the CAN module looks for another buffbuffer status to TX_NOT_ACTIVE. If the transmission pro- er transmit request and selects the buffer with the highest cess fails, the buffer condition will remain TX_BUSYx for re- priority for the next transmission by changing the buffer transmission until the frame was successfully transmitted or state from TX_ONCE to TX_BUSY. This transmit request the CPU has canceled the transmission request. can be canceled by the CPU or can be overwritten by anoth- 17.6 TRANSMIT STRUCTURE er transmit request of a buffer with a higher priority as long as the transmission of the next frame has not yet started. This means that between the beginning of the CRC field of the current frame and the transmission start of the next frame, two buffers, the current buffer and the buffer scheduled for the next transmission, are in the BUSY status. To cancel the transmit request of the next frame, the CPU must change the buffer state to TX_NOT_ACTIVE. When the transmit request has been overwritten by another request of a higher priority buffer, the CAN module changes the buffer state from TX_BUSY to TX_ONCE. Therefore, the transmit To answer Remote Frames, the CPU writes TX_RTR in the request remains pending. Figure 38 further illustrates the buffer status register, which causes the buffer to wait for a transmit timing. remote frame. When a remote frame passes the accepTo Send a Remote Frame (Remote Transmission Request) to other CAN nodes, software sets the RTR bit of the message identifier (see Storage of Remote Messages on page 105) and changes the status of the message buffer to TX_ONCE. After this remote frame has been transmitted successfully, this message buffer will automatically enter the RX_READY state and is ready to receive the appropriate answer. Note that the mask bits RTR/XRTR need to be set to receive a data frame (RTR = 0) in a buffer which was configured to transmit a remote frame (RTR = 1). BUS IDLE SOF 1 BIT ARBITRATION FIELD + CONTROL 12/29 BIT + 6 BIT DATA FIELD (IF PRESENT) n × 8 BIT CRC FIELD 16 BIT ACK FIELD 2 BIT EOF 7 BIT IFS 3 BIT BUS TX_BUSY current buffer CPU write TX_ONCE in buffer status TX_BUSY next buffer Begin selection of next buffer if new tx_request Figure 38. DS040 Data Transmission If the transmit process fails or the arbitration is lost, the transmission process will be stopped and will continue after the interrupting reception or the error signaling has finished (see Figure 38). In that case, a new buffer select follows and the TX process is executed again. 17.6.2 Transmit Priority The CAN module is able to generate a stream of scheduled messages without releasing the bus between two messages so that an optimized performance can be achieved. It will arbitrate for the bus immediately after sending the previous message and will only release the bus due to a lost arbitration. Note: The canceled message can be delayed by a TX request of a buffer with a higher priority. While TX_BUSY is high, software cannot change the contents of the message If more than one buffer is scheduled for transmission, the buffer object. In all cases, writing to the BUSY bit will be ig- priority is built by the message buffer number and the priornored. ity code in the CNSTAT register. The 8-bit value of the priorwww.national.com 96 7 4 3 17.6.3 The transmission of a CAN message must be executed as follows (see also Figure 39) 1. Configure the CNSTAT status field as TX_NOT_ACTIVE. If the status is TX_BUSY, a previous transmit request is still pending and software has no access to the data contents of the buffer. In that case, software may choose to wait until the buffer becomes available again as shown. Other options are to exit from the update routine until the buffer has been transmitted with an interrupt generated, or the transmission is aborted by an error. 2. Load buffer identifier and data registers. (For remote frames the RTR bit of the identifier needs to be set and loading data bytes can be omitted.) 3. Configure the CNSTAT status field to the desired value: — TX_ONCE to trigger the transmission process of a single frame. — TX_ONCE_RTR to trigger the transmission of a single data frame and then wait for a received remote frame to trigger consecutive data frames. — TX_RTR waits for a remote frame to trigger the transmission of a data frame. 0 TXPRI BUFFER # Table 37 shows the transmit priority configuration if the priority is TXPRI = 0 for all transmit buffers: Table 37 Transmit Priority (TXPRI = 0) TXPRI Buffer Number PRI TX Priority 0 0 0 Highest 0 1 1 : : : : : : : : 0 14 14 Lowest Table 38 shows the transmit priority configuration if TXPRI is different from the buffer number: Table 38 Transmit Priority (TXPRI not 0) TXPRI Buffer Number PRI TX Priority 14 0 224 Lowest 13 1 209 12 2 194 11 3 179 10 4 164 9 5 149 8 6 134 7 7 119 6 8 104 5 9 89 4 10 74 3 11 59 2 12 44 1 13 29 0 14 14 Transmit Procedure Writing TX_ONCE or TX_ONCE_RTR in the CNSTAT status field will set the internal transmit request for the CAN module. If a buffer is configured as TX_RTR and a remote frame is received, the data contents of the addressed buffer will be transmitted automatically without further CPU activity. Write_buffer Write TX_NOT_ACTIVE TX_BUSYx? Yes No Write ID/data Write TX_ONCE or TX_ONCE_RTR or TX_RTR Exit Highest DS041 Note: If two buffers have the same priority (PRI), the buffer with the lower buffer number will have the higher priority. 97 Figure 39. Buffer Write Routine www.national.com CP3CN23 ity is combined by the 4-bit TXPRI value and the 4-bit buffer number (0...14) as shown below. The lowest resulting number results in the highest transmit priority. CP3CN23 17.6.4 TX Buffer States If the CPU configures the message buffer to The transmission process can be started after software has TX_ONCE_RTR, it will transmit its data contents. During the loaded the buffer registers (data, ID, DLC, PRI) and set the transmission, the buffer state is 1111b as the CPU wrote buffer status from TX_NOT_ACTIVE to TX_ONCE, 1110b into the status section of the CNSTAT register. After the successful transmission, the buffer enters the TX_RTR TX_RTR, or TX_ONCE_RTR. state and waits for a remote frame. When it receives a reWhen the CPU writes TX_ONCE, the buffer will be mote frame, it will go back into the TX_ONCE_RTR state, TX_BUSY as soon as the CAN module has scheduled this transmit its data bytes, and return to TX_RTR. If the CPU buffer for the next transmission. After the frame could be writes 1010b into the buffer status section, it will only enter successfully transmitted, the buffer status will be automati- the TX_RTR state, but it will not send its data bytes before cally reset to TX_NOT_ACTIVE when a data frame was it waits for a remote frame. Figure 40 illustrates the possible transmitted or to RX_READY when a remote frame was transmit buffer states. transmitted. TX_ONCE_RTR 1110 CAN schedules TX RTR received TX request CPU writes 1110 TX_BUSY2 1111 transmit failed Transmit request cancelled CPU writes 1000 TX done CPU writes 1010 TX_RTR 1010 TX_NOT_ACTIVE 1000 TX request CPU writes 1100 TX_ONCE 1100 TX done CAN schedules TX TX request delayed by a TX request of higher priority message RX_READY 0010 Remote transmission request sent - now wait to receive a data frame Transmit request cancelled CPU writes 1000 TX_BUSY0 1101 transmit failed DS042 Figure 40. Transmit Buffer States — Successful response to a remote frame. (Buffer state changes from TX_ONCE_RTR to TX_RTR.) The CAN module has one dedicated ICU interrupt vector for — Transmit scheduling. (Buffer state changes from all interrupt conditions. In addition, the data frame receive TX_RTR to TX_ONCE_RTR.) event is an input to the MIWU (see Section 13.0). The inter CAN error conditions rupt process can be initiated from the following sources. — Detection of an CAN error. (The CEIPND bit in the CAN data transfer CIPND register will be set as well as the correspond— Reception of a valid data frame in the buffer. (Buffer ing bits in the error diagnostic register CEDIAG.) state changes from RX_READY to RX_FULL or The receive/transmit interrupt access to every message RX_OVERRUN.) buffer can be individually enabled/disabled in the CIEN reg— Successful transmission of a data frame. (Buffer state ister. The pending flags of the message buffer are located in changes from TX_ONCE to TX_NOT_ACTIVE or the CIPND register (read only) and can be cleared by resetRX_READY.) ting the flags in the CICLR registers. 17.7 INTERRUPTS www.national.com 98 Table 39 Highest Priority Interrupt Code (ICEN=FFFF) Highest Priority Interrupt Code To reduce the decoding time for the CIPND register, the buffer interrupt request with the highest priority is placed as interrupt status code into the IST[3:0] section of the CSTPND register. CAN Interrupt Request IRQ IST3 IST2 IST1 IST0 Buffer 10 1 1 0 1 1 Each of the buffer interrupts as well as the error interrupt Buffer 11 1 1 1 0 0 can be individually enabled or disabled in the CAN Interrupt Buffer 12 1 1 1 0 1 Enable register (CIEN). As soon as an interrupt condition occurs, every interrupt request is indicated by a flag in the Buffer 13 1 1 1 1 0 CAN Interrupt Pending register (CIPND). When the interrupt Buffer 14 1 1 1 1 1 code logic for the present highest priority interrupt request is enabled, this interrupt will be translated into the IST3:0 bits of the CAN Status Pending register (CSTPND). An in- 17.7.2 Usage Hints terrupt request can be cleared by setting the corresponding The interrupt code IST3:0 can be used within the interrupt bit in the CAN Interrupt Clear register (CICLR). handler as a displacement to jump to the relevant subrouFigure 41 shows the CAN interrupt management. tine. The CAN Interrupt Code Enable (CICEN) register is used in the CAN interrupt handler if software is servicing all receive buffer interrupts first, followed by all transmit buffer interrupts. In this case, software can first enable only receive buffer interrupts to be coded, then scan and service all pending interrupt requests in the order of their priority. After processing all the receive interrupts, software changes the CICEN register to disable all receive buffers and enable all transmit buffers, then services all pending transmit buffer interrupt requests according to their priorities. CIEN CICLR Clear interrupt flags of every message buffer individually CIPND 17.8 CICEN The CAN module features a free running 16-bit timer (CTMR) incrementing every bit time recognized on the CAN bus. The value of this timer during the ACK slot is captured into the TSTP register of a message buffer after a successful transmission or reception of a message. Figure 42 shows a simplified block diagram of the Time Stamp counter. ICODE IRQ IST3 IST2 IST1 TIME STAMP COUNTER IST0 DS043 Figure 41. Interrupt Management The highest priority interrupt source is translated into the bits IRQ and IST3:0 as shown in Table 39. CAN bits on the bus ACK slot and buffer 0 active +1 Reset 16-Bit counter Table 39 Highest Priority Interrupt Code (ICEN=FFFF) CAN Interrupt Request ACK slot IRQ IST3 IST2 IST1 IST0 No Request 0 0 0 0 0 Error Interrupt 1 0 0 0 0 Buffer 0 1 0 0 0 1 Buffer 1 1 0 0 1 0 Buffer 2 1 0 0 1 1 Buffer 3 1 0 1 0 0 Buffer 4 1 0 1 0 1 Buffer 5 1 0 1 1 0 Buffer 6 1 0 1 1 1 Buffer 7 1 1 0 0 0 Buffer 8 1 1 0 0 1 Buffer 9 1 1 0 1 0 TSTP register DS044 Figure 42. Time Stamp Counter The timer can be synchronized over the CAN network by receiving or transmitting a message to or from buffer 0. In this case, the TSTP register of buffer 0 captures the current CTMR value during the ACK slot of a message (as above), and then the CTMR is reset to 0000b. Synchronization can be enabled or disabled using the CGCR.TSTPEN bit. 99 www.national.com CP3CN23 17.7.1 CP3CN23 17.9 MEMORY ORGANIZATION vide single-cycle word and byte access without any potential wait state. Each CAN module occupies 144 words in the memory address space. This space is organized as 15 banks of 8 All register descriptions within the next sections have the folwords per bank (plus one reserved bank) for the message lowing layout: buffers and 14 words (plus 2 reserved words) for control and status. 15 0 17.9.1 CPU Access to CAN Registers/Memory Bit/Field Names All memory locations occupied by the message buffers are shared by the CPU and CAN module (dual-ported RAM). The CAN module and the CPU normally have single-cycle access to this memory. However, if an access contention occurs, the access to the memory is blocked every cycle until the contention is resolved. This internal access arbitration is transparent to software. Both word and byte access to the buffer RAM are allowed. If a buffer is busy during the reception of an object (copy process from the hidden receive buffer) or is scheduled for transmission, the CPU has no write access to the data contents of the buffer. Write to the status/control byte and read access to the whole buffer is always enabled. All configuration and status registers can either be accessed by the CAN module or the CPU only. These registers pro- Reset Value CPU Access (R = read only, W = write only, R/W = read/write) 17.9.2 Message Buffer Organization The message buffers are the communication interfaces between CAN and the CPU for the transmission and the reception of CAN frames. There are 15 message buffers located at fixed addresses in the RAM location. As shown in Table 40, each buffer consists of two words reserved for the identifiers, 4 words reserved for up to eight CAN data bytes, one word reserved for the time stamp, and one word for data length code, transmit priority code, and the buffer status codes. Table 40 Message Buffer Map Address Buffer Register 0E F0XEh ID1 15 14 13 12 11 10 9 8 7 6 5 4 3 SRR IDE /RTR XI[28:18]/ID[10:0] 0E F0XCh ID0 0E F0XAh DATA0 Data1[7:0] Data2[7:0] 0E F0X8h DATA1 Data3[7:0] Data4[7:0] 0E F0X6h DATA2 Data5[7:0] Data6[7:0] 0E F0X4h DATA3 Data7[7:0] 0E F0X2h TSTP 0E F0X0h CNSTAT www.national.com 2 1 XI[17:15] XI[14:0] RTR Data8[7:0] TSTP[15:0] DLC Reserved 100 0 PRI ST CAN CONTROLLER REGISTERS CP3CN23 17.10 Table 41 CAN Controller Registers Table 41 lists the CAN registers. Table 41 CAN Controller Registers Name Address Description CIEN1 0E F30Ch CAN Interrupt Enable Register 1 Name Address Description CNSTAT See Table 40 CAN Buffer Status/ Control Register CIPND1 0E F30Eh CAN Interrupt Pending Register 1 0E F100h CAN Global Configuration Register 0 CICLR1 0E F310h CAN Interrupt Clear Register 1 CICEN1 0E F312h 0E F102h CAN Timing Register 0 CAN Interrupt Code Enable Register 1 CSTPND1 0E F314h 0E F104h Global Mask Register 0 CAN Status Pending Register 1 CANEC1 0E F316h CAN Error Counter Register 1 CEDIAG1 0E F318h CAN Error Diagnostic Register 1 CTMR1 0E F31Ah CAN Timer Register 1 CGCR0 CTIM0 GMSKX0 0E F106h Global Mask Register 0 0E F108h Basic Mask Register 0 BMSKB0 0E F10Ah Basic Mask Register 0 CIEN0 0E F10Ch CAN Interrupt Enable Register 0 CIPND0 0E F10Eh CAN Interrupt Pending Register 0 CICLR0 0E F110h CAN Interrupt Clear Register 0 CICEN0 0E F112h CAN Interrupt Code Enable Register 0 GMSKB0 BMSKX0 17.10.1 Buffer Status/Control Register (CNSTAT) The buffer status (ST), the buffer priority (PRI), and the data length code (DLC) are controlled by manipulating the contents of the Buffer Status/Control Register (CNSTAT). The CPU and CAN module have access to this register. 15 DLC 8 7 Reserved 4 3 PRI 0 ST 0 R/W 0E F114h CAN Status Pending Register 0 CANEC0 0E F116h CAN Error Counter Register 0 CEDIAG0 0E F118h CAN Error Diagnostic Register 0 CTMR0 0E F11Ah CAN Timer Register 0 CGCR1 0E F300h CAN Global Configuration Register 1 CTIM1 0E F302h CAN Timing Register 1 GMSKX1 0E F304h Global Mask Register 1 GMSKB1 0E F306h Global Mask Register 1 BMSKX1 0E F308h Basic Mask Register 1 BMSKB1 0E F30Ah Basic Mask Register 1 CSTPND0 12 11 ST 101 The Buffer Status field contains the status information of the buffer as shown in Table 42. This field can be modified by the CAN module. The ST0 bits acts as a buffer busy indication. When the BUSY bit is set, any write access to the buffer is disabled with the exception of the lower byte of the CNSTAT register. The CAN module sets this bit if the buffer data is currently copied from the hidden buffer or if a message is scheduled for transmission or is currently transmitting. The CAN module always clears this bit on a status update. www.national.com CP3CN23 Table 42 Buffer Status Section of the CNSTAT Register ST3 (DIR) ST2 ST1 ST0 (BUSY) Buffer Status 0 0 0 0 RX_NOT_ACTIVE 0 0 0 1 Reserved for RX_BUSY. (This condition indicates that software wrote RX_NOT_ACTIVE to a buffer when the data copy process is still active.) 0 0 1 0 RX_READY 0 0 1 1 RX_BUSY0 (Indicates data is being copied for the first time RX_READY → RX_BUSY0.) 0 1 0 0 RX_FULL 0 1 0 1 RX_BUSY1 (Indicates data is being copied for the second time RX_FULL → RX_BUSY1.) 0 1 1 0 RX_OVERRUN 0 1 1 1 RX_BUSY2 (Indicates data is being copied for the third or subsequent times RX_OVERRUN → RX_BUSY2.) 1 0 0 0 TX_NOT_ACTIVE 1 0 0 1 Reserved for TX_BUSY. (This state indicates that software wrote TX_NOT_ACTIVE to a transmit buffer which is scheduled for transmission or is currently transmitting.) 1 1 0 0 TX_ONCE 1 1 0 1 TX_BUSY0 (Indicates that a buffer is scheduled for transmission or is actively transmitting; it can be due to one of two cases: a message is pending for transmission or is currently transmitting, or an automated answer is pending for transmission or is currently transmitting.) 1 0 1 0 TX_RTR (Automatic response to a remote frame.) 1 0 1 1 Reserved for TX_BUSY1. (This condition does not occur.) 1 1 1 0 TX_ONCE_RTR (Changes to TX_RTR after transmission.) 1 TX_BUSY2 (Indicates that a buffer is scheduled for transmission or is actively transmitting; it can be due to one of two cases: a message is pending for transmission or is currently transmitting, or an automated answer is pending for transmission or is currently transmitting.) 1 www.national.com 1 1 102 DLC The Transmit Priority Code field holds the software-defined transmit priority code for the message buffer. The Data Length Code field determines the number of data bytes within a received/transmitted frame. For transmission, these bits need to be set according to the number of data bytes to be transmitted. For reception, these bits indicate the number of valid received data bytes available in the message buffer. Table 43 shows the possible bit combinations for DLC3:0 for data lengths from 0 to 8 bytes. Note: The maximum number of data bytes received/transmitted is 8, even if the DLC field is set to a value greater than 8. Therefore, if the data length code is greater or equal to eight bytes, the DLC field is ignored. 17.10.2 Storage of Standard Messages During the processing of standard frames, the ExtendedIdentifier (IDE) bit is clear. The ID1[3:0] and ID0[15:0] bits are “don’t care” bits. A standard frame with eight data bytes is shown in Table 44. IDE The Identifier Extension bit determines whether the message is a standard frame or an extended frame. 0 – Message is a standard frame using 11 identifier bits. 1 – Message is an extended frame. The Remote Transmission Request bit indicates whether the message is a data frame or a remote frame. 0 – Message is a data frame. 1 – Message is a remote frame. The ID field is used for the 11 standard frame identifier bits. Table 43 Data Length Coding DLC Number of Data Bytes 0000 0 0001 1 0010 2 0011 3 0100 4 0101 5 0110 6 0111 7 1000 8 RTR ID Table 44 Standard Frame with 8 Data Bytes Address Buffer Register 0E F0XEh ID1 0E F0XCh ID0 0E F0XAh DATA0 Data1[7:0] Data2[7:0] 0E F0X8h DATA1 Data3[7:0] Data4[7:0] 0E F0X6h DATA2 Data5[7:0] Data6[7:0] 0E F0X4h DATA3 Data7[7:0] Data8[7:0] 0E F0X2h TSTP 0E F0X0h CNSTAT 15 14 13 12 11 10 9 8 7 6 5 ID[10:0] 4 3 RTR IDE 2 1 0 Don’t Care Don’t Care TSTP[15:0] DLC Reserved 103 PRI ST www.national.com CP3CN23 PRI CP3CN23 17.10.3 Storage of Messages with Less Than 8 Data Bytes 17.10.4 Storage of Extended Messages The data bytes that are not used for data transfer are “don’t cares”. If the object is transmitted, the data within these bytes will be ignored. If the object is received, the data within these bytes will be overwritten with invalid data. If the IDE bit is set, the buffer handles extended frames. The storage of the extended ID follows the descriptions in Table 45. The SRR bit is at the bit position of the RTR bit for standard frame and needs to be transmitted as 1. Table 45 Extended Messages with 8 Data Bytes Address Buffer Register 0E F0XEh ID1 15 14 13 12 11 10 9 8 7 6 5 ID[28:18] 4 3 SRR IDE 0E F0XCh ID0 0E F0XAh DATA0 Data1[7:0] Data2[7:0] 0E F0X8h DATA1 Data3[7:0] Data4[7:0] 0E F0X6h DATA2 Data5[7:0] Data6[7:0] 0E F0X4h DATA3 Data7[7:0] 0E F0X2h TSTP 0E F0X0h CNSTAT SRR IDE RTR ID 1 RTR Data8[7:0] TSTP[15:0] DLC Reserved 104 0 ID17:15] ID[14:0] The Substitute Remote Request bit replaces the RTR bit used in standard frames at this bit position. The SRR bit needs to be set by software if the buffer is configured to transmit a message with an extended identifier. It will be received as monitored on the CAN bus. The Identifier Extension bit determines whether the message is a standard frame or an extended frame. 0 – Message is a standard frame using 11 identifier bits. 1 – Message is an extended frame. The Remote Transmission Request bit indicates whether the message is a data frame or a remote frame. 0 – Message is a data frame. 1 – Message is a remote frame. The ID field is used to build the 29-bit identifier of an extended frame. www.national.com 2 PRI ST During remote frame transfer, the buffer registers DATA0– DATA3 are “don’t cares”. If a remote frame is transmitted, the contents of these registers are ignored. If a remote frame is received, the contents of these registers will be overwritten with invalid data. The structure of a message buffer set up for a remote frame with extended identifier is shown in Table 46. Table 46 Extended Remote Frame Address Buffer Register 0E F0XEh ID1 0E F0XCh ID0 0E F0XAh DATA0 0E F0X8h DATA1 0E F0X6h DATA2 0E F0X4h DATA3 0E F0X2h TSTP 0E F0X0h CNSTAT SRR IDE RTR ID 15 14 13 12 11 10 9 8 7 6 5 ID[28:18] 4 3 SRR IDE 2 1 0 ID17:15] ID[14:0] RTR Don’t Care TSTP DLC Reserved PRI ST The Substitute Remote Request bit replaces the RTR bit used in standard frames at this bit position. The SRR bit needs to be set by software. The Identifier Extension bit determines whether the message is a standard frame or an extended frame. 0 – Message is a standard frame using 11 identifier bits. 1 – Message is an extended frame. The Remote Transmission Request bit indicates whether the message is a data frame or a remote frame. 0 – Message is a data frame. 1 – Message is a remote frame. The ID field is used to build the 29-bit identifier of an extended frame. The ID[28:18] field is used for the 11 standard frame identifier bits. 105 www.national.com CP3CN23 17.10.5 Storage of Remote Messages CP3CN23 17.10.6 CAN Global Configuration Register (CGCRn) TSTPEN The CGCRn register is a 16-bit wide register used to: Enable/disable the CAN module. Configure the BUFFLOCK function for the message buffer 0..14. Enable/disable the time stamp synchronization. Set the logic levels of the CAN Input/Output pins, CANRX and CANTX. Choose the data storage direction (DDIR). Select the error interrupt type (EIT). Enable/disable diagnostic functions. 7 6 5 4 3 2 1 DDIR 0 TST BUFF IGNACK LO DDIR CRX CTX CANEN PEN LOCK 0 R/W 15 12 Reserved 11 10 9 8 EIT DIAGEN INTERNAL LOOPBACK 0 R/W CANEN The CAN Enable bit enables/disables the CAN module. When the CAN module is disabled, all internal states and the TEC and REC counter registers are cleared. In addition the CAN module clock is disabled. All CAN module control registers and the contents of the object memory are left unchanged. Software must make sure that no message is pending for transmission before the CAN module is disabled. 0 – CAN module is disabled. 1 – CAN module is enabled. CTX The Control Transmit bit configures the logic level of the CAN transmit pin CANTX. 0 – Dominant state is 0; recessive state is 1. 1 – Dominant state is 1; recessive state is 0. CRX The Control Receive bit configures the logic level of the CAN receive pin CANRX. 0 – Dominant state is 0; recessive state is 1. 1 – Dominant state is 1; recessive state is 0. BUFFLOCK The Buffer Lock bit configures the buffer lock function. If this feature is enabled, a buffer will be locked upon a successful frame reception. The buffer will be unlocked again by writing RX_READY in the buffer status register, i.e., after reading data. 0 – Lock function is disabled for all buffers. 1 – Lock function is enabled for all buffers. www.national.com 106 The Time Sync Enable bit enables or disables the time stamp synchronization function of the CAN module. 0 – Time synchronization disabled. The Time Stamp counter value is not reset upon reception or transmission of a message to/ from buffer 0. 1 – Time synchronization enabled. The Time Stamp counter value is reset upon reception or transmission of a message to/from buffer 0. The Data Direction bit selects the direction the data bytes are transmitted and received. The CAN module transmits and receives the CAN Data1 byte first and the Data8 byte last (Data1, Data2,...,Data7, Data8). If the DDIR bit is clear, the data contents of a received message is stored with the first byte at the highest data address and the last data at the lowest data address (see Figure 43). The same applies for transmitted data. 0 – First byte at the highest address, subsequent bytes at lower addresses. 1 – First byte at the lowest address, subsequent bytes at higher addresses. CP3CN23 Sequence of Data Bytes on the Bus ID Data1 Data2 Data3 Data4 Data5 Data6 Data7 Data8 CRC t ADDR Offset Storage of Data Bytes in the Buffer Memory Data Bytes 0A16 Data1 Data2 0816 Data3 Data4 0616 Data5 Data6 0416 Data7 Data8 DS045 Figure 43. Data Direction Bit Clear Setting the DDIR bit will cause the direction of the data storage to be reversed — the last byte received is stored at the highest address and the first byte is stored at the lowest address, as shown in Figure 44. Sequence of Data Bytes on the Bus ID Data1 Data2 Data3 Data4 Data5 Data6 Data7 Data8 CRC t Storage of Data Bytes in the Buffer Memory Figure 44. LO ADDR Offset Data Bytes 0A16 Data8 Data7 0816 Data6 Data5 0616 Data4 Data3 0416 Data2 Data1 DS046 Data Direction Bit Set The Listen Only bit can be used to configure the CAN interface to behave only as a receiver. This means: • Cannot transmit any message. • Cannot send a dominant ACK bit. • When errors are detected on the bus, the CAN module will behave as in the error passive mode. Using this listen only function, the CAN interface can be adjusted for connecting to an operating network with unknown bus speed. 0 – Transmit/receive mode. 1 – Listen-only mode. IGNACK LOOPBACK 107 When the Ignore Acknowledge bit is set, the CAN module does not expect to receive a dominant ACK bit to indicate the validity of a transmitted message. It will not send an error frame when the transmitted frame is not acknowledged by any other CAN node. This feature can be used in conjunction with the LOOPBACK bit for stand-alone tests outside of a CAN network. 0 – Normal mode. 1 – The CAN module does not expect to receive a dominant ACK bit to indicate the validity of a transmitted message. When the Loopback bit is set, all messages sent by the CAN module can also be received by a CAN module buffer with a matching buffer ID. However, the CAN module does not acknowledge a message sent by itself. Therefore, the CAN module will send an error frame when no other device connected to the bus has acknowledged the message. 0 – No loopback. 1 – Loopback enabled. www.national.com CP3CN23 INTERNAL DIAGEN EIT If the Internal function is enabled, the CANTX and CANRX pins of the CAN module are internally connected to each other. This feature can be used in conjunction with the LOOPBACK mode. This means that the CAN module can receive its own sent messages without connecting an external transceiver chip to the CANTX and CANRX pins; it allows software to run real stand-alone tests without any peripheral devices. 0 – Normal mode. 1 – Internal mode. The Diagnostic Enable bit globally enables or disables the special diagnostic features of the CAN module. This includes the following functions: • LO (Listen Only). • IGNACK (Ignore Acknowledge). • LOOPBACK (Loopback). • INTERNAL (Internal Loopback). • Write access to hidden receive buffer. 0 – Normal mode. 1 – Diagnostic features enabled. The Error Interrupt Type bit configures when the Error Interrupt Pending Bit (CIPND.EIPND) is set and an error interrupt is generated if enabled by the Error Interrupt Enable (CIEN.EIEN). 0 – The EIPND bit is set on every error on the CAN bus. 1 – The EIPND bit is set only if the error state (CSTPND.NS) changes as a result of incrementing either the receive or transmit error counter. 17.10.7 CAN Timing Register (CTIM) The Can Timing Register (CTIM) defines the configuration of the Bit Time Logic (BTL). 15 9 8 PSC 7 6 SJW 3 2 TSEG1 0 TSEG2 0 R/W PSC The Prescaler Configuration field specifies the CAN prescaler. The settings are shown in Table 47 Table 47 CAN Prescaler Settings SJW PSC6:0 Prescaler 000000 2 000001 3 000010 4 000011 5 000100 6 : : 1111101 127 1111110 128 1111111 128 The Synchronization Jump Width field specifies the Synchronization Jump Width, which can be programmed between 1 and 4 time quanta (see Table 48). Table 48 SJW Settings SJW Synchronization Jump Width (SJW) 00 1 time quantum 01 2 time quanta 10 3 time quanta 11 4 time quanta Note: The settings of SJW must be configured to be smaller or equal to TSEG1 and TSEG2 www.national.com 108 The Time Segment 1 field configures the length of the Time Segment 1 (TSEG1). It is not recommended to configure the time segment 1 to be smaller than 2 time quanta. (see Table 49). Table 49 Time Segment 1 Settings 17.10.8 Global Mask Register (GMSKBn/GMSKXn) The GMSKBn and GMSKXn registers allow software to globally mask, or “don’t care” the incoming extended/standard identifier bits, RTR/XRTR and IDE. Throughout this document, the GMSKBn and GMSKXn 16-bit registers are referenced as a 32-bit register GMSK. The following are the bits for the GMSKBn register. TSEG1[3:0] TSEG2 Length of Time (TSEG1) 0000 Not recommended 0001 2 time quanta 0010 3 time quanta 0011 4 time quanta 0100 5 time quanta 0101 6 time quanta 0110 7 time quanta 0111 8 time quanta 1000 9 time quanta 1001 10 time quanta 1010 11 time quanta 1011 12 time quanta 1100 13 time quanta 1101 14 time quanta 1110 15 time quanta 1111 16 time quanta TSEG2 Length of TSEG2 000 1 time quantum 001 2 time quanta 010 3 time quanta 011 4 time quanta 100 5 time quanta 101 6 time quanta 110 7 time quanta 111 8 time quanta 15 5 GM28:18 4 3 RTR IDE 2 0 GM17:15 0 R/W The following are the bits for the GMSKXn register. 15 1 GM14:0 0 XRTR 0 R/W For all GMSKBn and GMSKXn register bits, the following applies: 0 – The incoming identifier bit must match the corresponding bit in the message buffer identifier register. 1 – Accept 1 or 0 (“don’t care”) in the incoming ID bit independent from the corresponding bit in the message buffer ID registers. The corresponding ID bit in the message buffer will be overwritten by the incoming identifier bits. When an extended frame is received from the CAN bus, all GMSK bits GM28:0, IDE, RTR, and XRTR are used to mask The Time Segment 2 field specifies the num- the incoming message. In this case, the RTR bit in the ber of time quanta (tq) for phase segment 2 GMSK register corresponds to the SRR bit in the message. The XRTR bit in the GMSK register corresponds to the RTR (see Table 50). bit in the message. Table 50 Time Segment 2 Settings During the reception of standard frames only the GMSK bits GM[28:18], RTR, and IDE are used. In this case, the GM[28:18] bits in the GMSK register correspond to the ID[10:0] bits in the message. Global Mask GM[28:18] RTR 109 IDE GM[17:0] XRTR Standard Frame ID[10:0] RTR Extended Frame ID[28:18] SRR IDE IDE Unused ID[17:0] RTR www.national.com CP3CN23 TSEG1 CP3CN23 17.10.9 Basic Mask Register (BMSKBn/BMSKXn) 17.10.10 CAN Interrupt Enable Register (CIENn) The BMSKBn and BMSKXn registers allow masking the The CIENn register enables the transmit/receive interrupts buffer 14, or “don’t care” the incoming extended/standard of the message buffers 0 through 14 as well as the CAN Eridentifier bits, RTR/XRTR, and IDE. Throughout this docu- ror Interrupt. ment, the two 16-bit registers BMSKBn and BMSKXn are referenced to as a 32-bit register BMSK. 15 14 0 The following are the bits for the BMSKB register. EIEN IEN 15 5 BM28:18 4 3 RTR IDE 2 0 0 R/W BM17:15 0 EIEN R/W The following are the bits for the BMSKX register. 15 1 BM14:0 0 XRTR 0 R/W IEN For all BMSKBn and BMSKXn register bits the following applies: The Error Interrupt Enable bit allows the CAN module to interrupt the CPU if any kind of CAN receive/transmit errors are detected. This causes any error status change in the error counter registers REC/TEC is able to generate an error interrupt. 0 – The error interrupt is disabled and no error interrupt will be generated. 1 – The error interrupt is enabled and a change in REC/TEC will cause an interrupt to be generated. The Buffer Interrupt Enable bits allow software to enable/disable the interrupt source for the corresponding message buffer. For example, IEN14 controls interrupts from buffer14, and IEN0 controls interrupts from buffer0. 0 – Buffer as interrupt source disabled. 1 – Buffer as interrupt source enabled. 0 – The incoming identifier bit must match the corresponding bit in the message buffer identifier register. 1 – Accept 1 or 0 (“don’t care”) in the incoming ID bit independent from the corresponding bit in the message 17.10.11 CAN Interrupt Pending Register (CIPNDn) buffer ID registers. The corresponding ID bit in the message buffer will be overwritten by the incoming identifier The CIPNDn register indicates any CAN Receive/Transmit Interrupt Requests caused by the message buffers 0..14 bits. and CAN error occurrences. When an extended frame is received from the CAN bus, all BMSK bits BM28:0, IDE, RTR, and XRTR are used to mask 15 14 0 the incoming message. In this case, the RTR bit in the BMSK register corresponds to the SRR bit in the message. The XRTR bit in the BMSK register corresponds to the RTR bit in the message. EIPND 0 During the reception of standard frames, only the BMSK bits BM[28:18], RTR, and IDE are used. In this case, the BM[28:18] bits in the BMSK register correspond to the EIPND ID[10:0] bits in the message. Basic Mask BM28:18 RTR IDE BM17:0 XRTR Standard Frame ID10:0 RTR IDE Unused Extended Frame ID28:18 SRR IDE www.national.com ID17:0 RTR IPND IPND 110 R The Error Interrupt Pending field indicates the status change of TEC/REC and will execute an error interrupt if the EIEN bit is set. Software has the responsibility to clear the EIPND bit using the CICLRn register. 0 – CAN status is not changed. 1 – CAN status is changed. The Buffer Interrupt Pending bits are set by the CAN module following a successful transmission or reception of a message to or from the corresponding message buffer. For example, IPND14 corresponds to buffer14, and IPND0 corresponds to buffer0. 0 – No interrupt pending for the corresponding message buffer. 1 – Message buffer has generated an interrupt. 17.10.14 CAN Status Pending Register (CSTPNDn) The CICLRn register bits individually clear CAN interrupt The CSTPNDn register holds the status of the CAN Node pending flags caused by the message buffers and from the and the Interrupt Code. Error Management Logic. Do not modify this register with instructions that access the register as a read-modify-write 15 8 7 5 4 3 0 operand, such as the bit manipulation instructions. Reserved NS IRQ IST 15 14 0 0 EICLR R ICLR 0 W EICLR ICLR NS Table 51 CAN Node Status The Error Interrupt Clear bit is used to clear the EIPND bit. 0 – The EIPND bit is unaffected by writing 0. 1 – The EIPND bit is cleared by writing 1. The Buffer Interrupt Clear bits are used to clear the IPND bits. 0 – The corresponding IPND bit is unaffected by writing 0. 0 – The corresponding IPND bit is cleared by writing 1. 17.10.13 CAN Interrupt Code Enable Register (CICENn) IRQ/IST The CICENn register controls whether the interrupt pending flag in the CIPNDn register is translated into the Interrupt Code field of the CSTPNDn register. All interrupt requests, CAN error, and message buffer interrupts can be enabled/ disabled separately for the interrupt code indication field. 15 14 NS Node Status 000 Not Active 010 Error Active 011 Error Warning Level 10X Error Passive 11X Bus Off The IRQ bit and IST field indicate the interrupt source of the highest priority interrupt currently pending and enabled in the CICENn register. Table 52 shows the several interrupt codes when the encoding for all interrupt sources is enabled (CICEN = FFFFh). Table 52 Highest Priority Interrupt Code 0 EICEN The CAN Node Status field indicates the status of the CAN node as shown in Table 51. ICEN IRQ IST3:0 CAN Interrupt Request 0 0000 No interrupt request 1 0000 Error interrupt 1 0001 Buffer 0 1 0010 Buffer 1 1 0011 Buffer 2 1 0100 Buffer 3 1 0101 Buffer 4 1 0110 Buffer 5 1 0111 Buffer 6 1 1000 Buffer 7 1 1001 Buffer 8 1 1010 Buffer 9 1 1011 Buffer 10 1 1100 Buffer 11 1 1101 Buffer 12 1 1110 Buffer 13 1 1111 Buffer 14 0 R/W EICEN ICEN The Error Interrupt Code Enable bit controls encoding for error interrupts. 0 – Error interrupt pending is not indicated in the interrupt code. 1 – Error interrupt pending is indicated in the interrupt code. The Buffer Interrupt Code Enable bits control encoding for message buffer interrupts. 0 – Message buffer interrupt pending is not indicated in the interrupt code. 1 – Message buffer interrupt pending is indicated in the interrupt code. 111 www.national.com CP3CN23 17.10.12 CAN Interrupt Clear Register (CICLRn) CP3CN23 Table 53 Error Field Identifier 17.10.15 CAN Error Counter Register (CANECn) The CANECn register reports the values of the CAN Receive Error Counter and the CAN Transmit Error Counter. 15 8 7 0 REC TEC EFID3:0 Field 1101 DLC 1110 DATA 1111 CRC 0 EBID R REC The CAN Receive Error Counter field reports the value of the receive error counter. The CAN Transmit Error Counter field reports the value of the transmit error counter. TEC The Error Bit Identifier field reports the bit position of the incorrect bit within the erroneous frame field. The bit number starts with the value equal to the respective frame field length minus one at the beginning of each field and is decremented with each CAN bit. Figure 45 shows an example on how the EBID is calculated. 17.10.16 CAN Error Diagnostic Register (CEDIAGn) The CEDIAGn register reports information about the last detected error. The CAN module identifies the field within the CAN frame format in which the error occurred, and it identifies the bit number of the erroneous bit within the frame field. The CPU bus master has read-only access to this register, and all bits are cleared on reset. 15 14 13 12 11 10 9 4 3 Res. DRIVE MON CRC STUFF TXE EBID r www.national.com 0000 ERROR 0001 ERROR DEL 0010 ERROR ECHO 0011 BUS IDLE 0100 ACK 0101 EOF 0110 INTERMISSION 0111 SUSPEND TRANSMISSION 1000 SOF 1001 ARBITRATION 1010 IDE 1011 EXTENDED ARBITRATION 1100 R1/R0 r DS047 Figure 45. EBID Example The Error Field Identifier field identifies the frame field in which the last error occurred. The encoding of the frame fields is shown in Table 53. Field r 0 R EFID3:0 r Data Field EFID Table 53 Error Field Identifier r Incorrect Bit 0 EFID r TXE STUFF CRC MON 112 For example, assume the EFID field shows 1110b and the EBID field shows 111001b. This means the faulty field was the data field. To calculate the bit position of the error, the DLC of the message needs to be known. For example, for a DLC of 8 data bytes, the bit counter starts with the value: (8 × 8) - 1 = 63; so when EBID[5:0] = 111001b = 57, then the bit number was 63 - 57 = 6. The Transmit Error bit indicates whether the CAN module was an active transmitter at the time the error occurred. 0 – The CAN module was a receiver at the time the error occurred. 1 – The CAN module was an active transmitter at the time the error occurred. The Stuff Error bit indicates whether the bit stuffing rule was violated at the time the error occurred. Note that certain bit fields do not use bit stuffing and therefore this bit may be ignored for those fields. 0 – No bit stuffing error. 1 – The bit stuffing rule was violated at the time the error occurred. The CRC Error bit indicates whether the CRC is invalid. This bit should only be checked if the EFID field shows the code of the ACK field. 0 – No CRC error occurred. 1 – CRC error occurred. The Monitor bit shows the bus value on the CANRX pin as sampled by the CAN module at the time of the error. The Drive bit shows the output value on the CANTX pin at the time of the error. Note that a receiver will not drive the bus except during ACK and during an active error flag. 17.10.17 CAN Timer Register (CTMRn) 17.11.1 External Connection The CAN module uses the CANnTX and CANnRX pins to connect to the physical layer of the CAN interface. They provide the functionality described in Table 54. Table 54 External CAN Pins The CTMRn register reports the current value of the Time Stamp Counter as described in Section 17.8. 15 0 Signal Name Type Description CANnTX Output Transmit data to the CAN bus CANnRX Input Receive data from the CAN bus CTMR15:0 The logic levels are configurable by the CTX and CRX bits of the Global Configuration Register CGCRn (see “CAN Global Configuration Register (CGCRn)” on page 106). 0 R 17.11.2 Transceiver Connection The CTMRn register is a free running 16-bit counter. It contains the number of CAN bits recognized by the CAN module since the register has been cleared. The counter starts to increment from the value 0000b after a hardware reset. If the Timer Stamp Enable bit (TSTPEN) in the CGCRn register is set, the counter will also be cleared on a message transfer of the message buffer 0. An external transceiver chip must be connected between the CAN block and the bus. It establishes a bus connection in differential mode and provides the driver and protection requirements. Figure 46 shows a possible ISO-High-Speed configuration. The contents of CTMR are captured into the Time Stamp register of the message buffer after successfully sending or receiving a frame, as described in “Time Stamp Counter” on page 99. 17.11 120 Termination CAN bus signals CPU Bus To other modules SYSTEM START-UP AND MULTI-INPUT WAKE-UP CR16CAN After system start-up, all CAN-related registers are in their reset state. The CAN module can be enabled after all configuration registers are set to their desired value. The following initial settings must be made: Configure the CAN Timing register (CTIM). See “Bit Time Logic” on page 90. Configure every buffer to its function as receive/transmit. See “Buffer Status/Control Register (CNSTAT)” on page 101. Set the acceptance filtering masks. See “Acceptance Filtering” on page 92. Enable the CAN interface. See “CAN Global Configuration Register (CGCRn)” on page 106. VCC Transceiver Chip 3 CANnRX CANnTX 5 REF 4 RX 1 TX VCC 7 BUS_H 6 BUS_L RS GND 8 2 120 DS282 Figure 46. External Transceiver Before disabling the CAN module, software must make sure 17.11.3 Timing Requirements that no transmission is still pending. Processing messages and updating message buffers reNote: Activity on the CAN bus can wake up the device from quire a certain number of clock cycles, as shown in a reduced-power mode by selecting the CANnRX pin as an Table 55. These requirements may lead to some restrictions input to the Multi-Input Wake-Up module. In this case, the regarding the Bit Time Logic settings and the overall CAN CAN module must not be disabled before entering the re- performance which are described below in more detail. Wait duced-power mode. Disabling the CAN module also dis- cycles need to be added to the cycle count for CPU access ables the CANnRX pin. As an alternative, the CANnRX pin to the object memory as described in CPU Access to CAN can be connected to any other input pin of the Multi-Input Registers/Memory on page 100. The number of occurrencWake-Up module. This input channel must then be config- es per frame is dependent on the number of matching idenured to trigger a wake-up event on a falling edge (if a domi- tifiers. nant bit is represented by a low level). In this case, the CAN module can be disabled before entering the reduced-power mode. After waking up, software must enable the CAN module again. All configuration and buffer registers still contain the same data they held before the reduced-power mode was entered. 113 www.national.com CP3CN23 DRIVE CP3CN23 Table 56 gives examples for the minimum clock frequency in order to ensure proper functionality at various CAN bus speeds. Table 55 CAN Module Internal Timing Task Cycle Count Occurrence/ Frame Copy hidden buffer to receive message buffer 17 0–1 Baud Rate Minimum Clock Frequency Update status from TX_RTR to TX_ONCE_RTR 3 0–15 1 Mbit/sec 15.25 MHz Schedule a message for transmission 2 0–1 500 kbit/sec 7.625 MHz 250 kbit/sec 3.81 MHz Table 56 Minimum Clock Frequency Requirements The critical path derives from receiving a remote frame, which triggers the transmission of one or more data frames. There are a minimum of four bit times in-between two consecutive frames. These bit times start at the validation point of received frame (reception of 6th EOF bit) and end at the earliest possible transmission start of the next frame, which is after the third intermission bit at 100% burst bus load. 17.11.4 Bit Time Logic Calculation Examples The calculation of the CAN bus clocks using CKI = 16 MHz is shown in the following examples. The desired baud rate for both examples is 1 Mbit/s. Example 1 These four bit times have to be set in perspective with the timing requirements of the CAN module. PSC = PSC[5:0] + 2 = 0 + 2 = 2 The minimum duration of the four CAN bit times is determined by the following Bit Time Logic settings: TSEG2 = TSEG2[2:0] + 1 = 2 + 1 = 3 TSEG1 = TSEG1[3:0] + 1 = 3 + 1 = 4 SJW = TSEG2 = 3 PSC = PSCmin = 2 Sample point positioned at 62.5% of bit time Bit time = 125 ns × (1 + 4 + 3 ± 3) = (1 ± 0.375) µs Bus Clock = 16 MHz / (2 × (1 + 4 + 3)) = 1 Mbit/s (nominal) TSEG1 = TSEG1min = 2 TSEG2 = TSEG2min = 1 Bit time = Sync + Time Segment 1 + Time Segment 2 = (1 + 2 + 1) tq = 4 tq = (4 tq × PSC) clock cycles = (4 tq × 2) clock cycles = 8 clock cycles Example 2 PSC = PSC[5:0] + 1 = 2 + 2 = 4 TSEG1 = TSEG1[3:0] + 1 = 1 + 1 = 2 For these minimum BTL settings, four CAN bit times take 32 TSEG2 = TSEG2[2:0] + 1 = 0 + 1 = 1 clock cycles. SJW = TSEG2 = 1 The following is an example that assumes typical case: Sample point positioned at 75% of bit time Bit time = 250 ns × (1 + 2 + 1 ± 1) = (1 ± 0.25) µs Minimum BTL settings Bus Clock = 16 MHz / (2 × (1 + 4 + 3)) = 1Mbit/s (nominal) Reception and copy of a remote frame Update of one buffer from TX_RTR 17.11.5 Acceptance Filter Considerations Schedule of one buffer from transmit The CAN module provides two acceptance filter masks As outlined in Table 55, the copy process, update, and GMSK and BMSK, as described in “Acceptance Filtering” scheduling the next transmission gives a total of 17 + 3 + 2 on page 92, “Global Mask Register (GMSKBn/GMSKXn)” = 22 clock cycles. Therefore under these conditions there is on page 109, and “Basic Mask Register (BMSKBn/BMno timing restriction. SKXn)” on page 110. These masks allow filtering of up to 32 The following example assumes the worst case: bits of the message object, which includes the standard identifier, the extended identifier, and the frame control bits Minimum BTL settings RTR, SRR, and IDE. Reception and copy of a remote frame Update of the 14 remaining buffers from TX_RTR Schedule of one buffer for transmit 17.11.6 Remote Frames All these actions in total require 17 + (14 × 3) + 2 = 61 clock cycles to be executed by the CAN module. This leads to the limitation of the Bit Time Logic of 61 / 4 = 15.25 clock cycles per CAN bit as a minimum, resulting in the minimum clock frequencies listed below. (The frequency depends on the desired baud rate and assumes the worst case scenario can occur in the application.) www.national.com Remote frames can be automatically processed by the CAN module. However, to fully enable this feature, the RTR/ XRTR bits (for both standard and extended frames) within the BMSK and/or GMSK register need to be set to “don’t care”. This is because a remote frame with the RTR bit set should trigger the transmission of a data frame with the RTR bit clear and therefore the ID bits of the received message need to pass through the acceptance filter. The same applies to transmitting remote frames and switching to receive the corresponding data frames. 114 CP3CN23 17.12 USAGE HINT Under certain conditions, the CAN module receives a frame sent by itself, even though the loopback feature is disabled. Two conditions must be true to cause this malfunction: A transmit buffer and at least one receive buffer are configured with the same identifier. Assume this identifier is called ID_RX_TX. With regard to the receive buffer, this means that the buffer identifier and the corresponding filter masks are set up in a way that the buffer is able to receive frames with the identifier ID_RX_TX. The following sequence of events occurs: 1. A message with the identifier ID_RX_TX from another CAN node is received into the receive buffer. 2. A message with the identifier ID_RX_TX is sent by the CAN module immediately after the reception took place. When these conditions occur, the frame sent by the CAN module will be copied into the next receive buffer available for the identifier ID_RX_TX. If a frame with an identifier different to ID_RX_TX is sent or received in between events 1 and 2, the problem does not occur. 115 www.national.com CP3CN23 18.0 Advanced Audio Interface The Advanced Audio Interface (AAI) provides a serial synchronous, full duplex interface to codecs and similar serial devices. The transmit and receive paths may operate asynchronously with respect to each other. Each path uses a 3wire interface consisting of a bit clock, a frame synchronization signal, and a data signal. The CPU interface can be either interrupt-driven or DMA. If the interface is configured for interrupt-driven I/O, data is buffered in the receive and transmit FIFOs. If the interface is configured for DMA, the data is buffered in registers. 18.1.4 Serial Receive Data (SRD) The SRD pin is used as an input when data is shifted into the Audio Receive Shift Register (ARSR). In asynchronous mode, data on the SRD pin is sampled on the negative edge of the serial receive shift clock (SRCLK). In synchronous mode, data on the SRD pin is sampled on the negative edge of the serial shift clock (SCK). The data is shifted into ARSR with the most significant bit (MSB) first. 18.1.5 Serial Receive Clock (SRCLK) The SRCLK pin is a bidirectional signal that provides the reThe AAI is functionally similar to a MotorolaTM Synchronous ceive serial shift clock in asynchronous mode. In this mode, Serial Interface (SSI). Compared to a standard SSI impledata is sampled on the negative edge of SRCLK. The SRmentation, the AAI interface does not support the so-called CLK signal may be generated internally or it may be provid“On-demand Mode”. It also does not allow gating of the shift ed by an external clock source. In synchronous mode, the clocks, so the receive and transmit shift clocks are always SCK pin is used as shift clock for both the receiver and active while the AAI is enabled. The AAI also does not suptransmitter, so the SRCLK pin is available for use as a genport 12- and 24-bit data word length or more than 4 slots eral-purpose port pin or an auxiliary frame sync signal to ac(words) per frame. The reduction of supported modes is access multiple slave devices (e.g. codecs) within a network ceptable, because the main purpose of the AAI is to connect (see Network mode). to audio codecs, rather than to other processors (DSPs). The implementation of a FIFO as a 16-word receive and 18.1.6 Serial Receive Frame Sync (SRFS) transmit buffer is an additional feature, which simplifies communication and reduces interrupt load. Independent DMA is provided for each of the four supported audio channels (slots). The AAI also provides special features and operating modes to simplify gain control in an external codec and to connect to an ISDN controller through an IOM-2 compatible interface. 18.1 AUDIO INTERFACE SIGNALS 18.1.1 Serial Transmit Data (STD) 18.2 The STD pin is used to transmit data from the serial transmit shift register (ATSR). The STD pin is an output when data is being transmitted and is in high-impedance mode when no data is being transmitted. The data on the STD pin changes on the positive edge of the transmit shift clock (SCK). The STD pin goes into high-impedance mode on the negative edge of SCK of the last bit of the data word to be transmitted, assuming no other data word follows immediately. If another data word follows immediately, the STD pin remains active rather than going to the high-impedance mode. 18.1.2 Serial Transmit Clock (SCK) The SCK pin is a bidirectional signal that provides the serial shift clock. In asynchronous mode, this clock is used only by the transmitter to shift out data on the positive edge. The serial shift clock may be generated internally or it may be provided by an external clock source. In synchronous mode, the SCK pin is used by both the transmitter and the receiver. Data is shifted out from the STD pin on the positive edge, and data is sampled on the SRD pin on the negative edge. 18.1.3 Serial Transmit Frame Sync (SFS) The SFS pin is a bidirectional signal which provides frame synchronization. In asynchronous mode, this signal is used as frame sync only by the transmitter. In synchronous mode, this signal is used as frame sync by both the transmitter and receiver. The frame sync signal may be generated internally, or it may be provided by an external source. www.national.com The SRFS pin is a bidirectional signal that provides frame synchronization for the receiver in asynchronous mode. The frame sync signal may be generated internally, or it may be provided by an external source. In synchronous mode, the SFS signal is used as the frame sync signal for both the transmitter and receiver, so the SRFS pin is available for use as a general-purpose port pin or an auxiliary frame sync signal to access multiple slave devices (e.g. codecs) within a network (see Network mode). AUDIO INTERFACE MODES There are two clocking modes: asynchronous mode and synchronous mode. These modes differ in the source and timing of the clock signals used to transfer data. When the AAI is generating the bit shift clock and frame sync signals internally, synchronous mode must be used. There are two framing modes: normal mode and network mode. In normal mode, one word is transferred per frame. In network mode, up to four words are transferred per frame. A word may be 8 or 16 bits. The part of the frame which carries a word is called a slot. Network mode supports multiple external devices sharing the interface, in which each device is assigned its own slot. Separate frame sync signals are provided, so that each device is triggered to send or receive its data during its assigned slot. 18.2.1 Asynchronous Mode In asynchronous mode, the receive and transmit paths of the audio interface operate independently, with each path using its own bit clock and frame sync signal. Independent clocks for receive and transmit are only used when the bit clock and frame sync signal are supplied externally. If the bit clock and frame sync signals are generated internally, both paths derive their clocks from the same set of clock prescalers. 116 Synchronous Mode In synchronous mode, the receive and transmit paths of the audio interface use the same shift clock and frame sync signal. The bit shift clock and frame sync signal for both paths are derived from the same set of clock prescalers. 18.2.3 Normal Mode data bytes or words available in the transmit FIFO is equal or less than a programmable warning limit. DMA Support If the receiver interface is configured for DMA (RXDSA0 = 1), received data is transferred from the ARSR into the DMA receive buffer 0 (ARDR0). A DMA request is asserted when the ARDR0 register is full. If the transmitter interface is configured for DMA (TXDSA0 = 1), data to be transmitted are read from the DMA transmit buffer 0 (ATDR0). A DMA request is asserted to the DMA controller when the ATDR0 register is empty. In normal mode, each rising edge on the frame sync signal marks the beginning of a new frame and also the beginning of a new slot. A slot does not necessarily occupy the entire frame. (A frame can be longer than the data word transmitted after the frame sync pulse.) Typically, a codec starts transmitting a fixed length data word (e.g. 8-bit log PCM da- Figure 48 shows the data flow for IRQ and DMA mode in ta) with the frame sync signal, then the codec’s transmit pin normal Mode. returns to the high-impedance state for the remainder of the DMA frame. SRD Request 1 The Audio Receive Shift Register (ARSR) de-serializes received on the SRD pin (serial receiver data). Only the data sampled after the frame sync signal are treated as valid. If the interface is interrupt-driven, valid data bits are transferred from the ARSR to the receive FIFO. If the interface is configured for DMA, the data is transferred to the receive DMA register 0 (ARDR0). ARSR =1 A DS TX DMA Slot Assignment TXDSA = 0 RX FIFO IRQ DMA Request 0 STD The serial transmit data (STD) pin is only an active output while data is shifted out. After the defined number of data bits have been shifted out, the STD pin returns to the highimpedance state. For operation in normal mode, the Slot Count Select bits (SCS[1:0]) in the Global Configuration register (AGCR) must be loaded with 00b (one slot per frame). In addition, the Slot Assignment bits for receive and transmit must be programmed to select slot 0. ARDR 0 ATSR SA =1 ATDR 0 D RX DMA Slot Assignment RXDSA = 0 TX FIFO IRQ DS054 Figure 48. IRQ/DMA Support in Normal Mode Network Mode If the interface is configured for DMA, the DMA slot assignment bits must also be programmed to select slot 0. In this case, the audio data is transferred to or from the receive or transmit DMA register 0 (ARDR0/ATDR0). In network mode, each frame is composed of multiple slots. Each slot may transfer 8 or 16 bits. All of the slots in a frame must have the same length. In network mode, the sync signal marks the beginning of a new frame. Only frames with Figure 47 shows the frame timing while operating in normal up to four slots are supported by this audio interface. mode with a long frame sync interval. More than two devices can communicate within a network using the same clock and data lines. The devices connected to the same bus use a time-multiplexed approach to share Long Frame Sync access to the bus. Each device has certain slots assigned (SFS/SRFS) to it, in which only that device is allowed to transfer data. One master device provides the bit clock and the frame sync High-impedance signal(s). On all other (slave) devices, the bit clock and Shift Data Data Data (STD/SRD) frame sync pins are inputs. Frame DS053 Figure 47. Up to four slots can be assigned to the interface, as it supports up to four slots per frame. Any other slots within the frame are reserved for other devices. Normal Mode Frame The transmitter only drives data on the STD pin during slots which have been assigned to this interface. During all other If the receiver interface is configured for interrupt-driven I/O slots, the STD output is in high-impedance mode, and data (RXDSA0 = 0), all received data are loaded into the receive can be driven by other devices. The assignment of slots to FIFO. An IRQ is asserted as soon as the number of data the transmitter is specified by the Transmit Slot Assignment bytes or words in the receive FIFO is greater than a pro- bits (TXSA) in the ATCR register. It can also be specified whether the data to be transmitted is transferred from the grammable warning limit. transmit FIFO or the corresponding DMA transmit register. If the transmitter interface is configured for interrupt-driven There is one DMA transmit register (ATDRn) for each of the I/O (TXDSA0 = 0), all data to be transmitted is read from the maximum four data slots. Each slot can be configured indetransmit FIFO. An IRQ is asserted as soon as the number pendently. IRQ Support 117 www.national.com CP3CN23 18.2.2 ta da 0 Sl ot Assignment Sl Figure 49 shows the frame timing while operating in network mode with four slots per frame, slot 1 assigned to the interface, and a long frame sync interval. ot ARDR 3 2 an d 3 da ta RX FIFO IRQ Long Frame Sync (SFS/SRFS) Data (ignored) Data (valid) Data (ignored) ATDR 0 STD ta Shift Data (STD/SRD) High-impedance 0 Slot1 ATDR 1 Unused Slots Frame DS055 DMA Slot Assignment DMA Request 2 1d 2 an d 3 da ta IRQ Support ATDR 2 ATDR 3 ot Network Mode Frame ata ot Sl Sl Figure 49. DMA Request 0 ot Slot0 da ATSR Sl CP3CN23 On the receiver side, only the valid data bits which were re- port enabled for slots 0 and 1 in receive and transmit direcceived during the slots assigned to this interface are copied tion. into the receive FIFO or DMA registers. The assignment of DMA slots to the receiver is specified by the Receive Slot AssignRequest 1 ARDR 0 ment bits (RXSA) in the ATCR register. It can also be specDMA ified whether the received data is copied into the receive SRD Request 3 ARSR ARDR 1 FIFO or into the corresponding DMA receive register. There is one DMA receive register (ARDRn) for each of the maxiata ARDR 2 mum four data slots. Each slot may be configured individu1d lot S DMA Slot ally. TX FIFO IRQ If DMA is not enabled for a receive slot n (RXDSAn = 0), all DS056 data received in this slot is loaded into the receive FIFO. An IRQ is asserted as soon as the number of data bytes or Figure 50. IRQ/DMA Support in Network Mode words in the receive FIFO is greater than a configured warnIf the interface operates in synchronous mode, the receiver ing limit. uses the transmit bit clock (SCK) and transmit frame sync If DMA is not enabled for a transmit slot n (TXDSAn = 0), all signal (SFS). This allows the pins used for the receive bit data to be transmitted in this slot are read from the transmit clock (SRCLK) and receive frame sync (SRFS) to be used FIFO. An IRQ is asserted as soon as the number data bytes as additional frame sync signals in network mode. The extra or words available in the transmit FIFO is equal or less than frame sync signals are useful when the audio interface coma configured warning limit. municates to more than one codec, because codecs typically start transmission immediately after the frame sync pulse. DMA Support If DMA support is enabled for a receive slot n (RXDSA0 = The SRCLK pin is driven with a frame sync pulse at the be1), all data received in this slot is only transferred from the ginning of the second slot (slot 1), and the SRFS pin is drivARSR into the corresponding DMA receive register en with a frame sync pulse at the beginning of slot 2. (ARDRn). A DMA request is asserted when the ARDRn reg- Figure 51 shows a frame timing diagram for this configuration, using the additional frame sync signals on SRCLK and ister is full. SRFS to address up to three devices. If DMA is enabled for a transmit slot n (TXDSAn = 1), all data to be transmitted in slot n are read from the corresponding DMA transmit register (ATDRn). A DMA request is asserted to the DMA controller when the ATDRn register is empty. Figure 50 illustrates the data flow for IRQ and DMA support in network mode, using four slots per frame and DMA sup- www.national.com 118 Pideal = fAudio In / fbit = 12 MHz / 256 kHz = 46.875 SFS Therefore, the real prescaler value is 47. This results in a bit clock error equal to: SRCLK (auxiliary frame sync) fbit_error = (fbit - fAudio In/Preal) / fbit × 100 = (256 kHz - 12 MHz/47) / 256 kHz × 100 = 0.27% SRFS (auxiliary frame sync) 18.4 Data from/to Data from/to Data from/to Codec 1 Codec 2 Codec 3 STD/SRD Slot 0 Slot 1 Slot 2 Slot 3 Frame DS057 Figure 51. 18.3 Accessing Three Devices in Network Mode BIT CLOCK GENERATION An 8-bit prescaler is provided to divide the audio interface input clock down to the required bit clock rate. Software can choose between two input clock sources, a primary and a secondary clock source. On the CP3CN23, the two optional input clock sources are the 12-MHz Aux1 clock and the 48-MHz PLL output clock. The input clock is divided by the value of the prescaler BCPRS[7:0] + 1 to generate the bit clock. FRAME CLOCK GENERATION The clock for the frame synchronization signals is derived from the bit clock of the audio interface. A 7-bit prescaler is used to divide the bit clock to generate the frame sync clock for the receive and transmit operations. The bit clock is divided by FCPRS + 1. In other words, the value software must write into the ACCR.FCPRS field is equal to the bit number per frame minus one. The frame may be longer than the valid data word but it must be equal to or larger than the 8- or 16-bit word. Even if 13-, 14-, or 15-bit data is being used, the frame width must always be at least 16 bits wide. In addition, software can specify the length of a long frame sync signal. A long frame sync signal can be either 6, 13, 14, 15, or 16 bits long, depending on the external codec being used. The frame sync length can be configured by the Frame Sync Length field (FSL) in the AGCR register. 18.5 AUDIO INTERFACE OPERATION 18.5.1 Clock Configuration The bit clock rate fbit can be calculated by the following The Aux1 clock (generated by the Clock module described equation: in Section 11.9) must be configured, because it is the time base for the AAI module. Software must write an approprifbit = n × fSample × Data Length ate divisor to the ACDIV1 field of the PRSAC register to pron = Number of Slots per Frame vide a 12 MHz input clock. Software also must enable the fSample = Sample Frequency in Hz Aux1 clock by setting the ACE1 bit in the CRCTRL register. Data Length = Length of data word in multiples of 8 bits For example: The ideal required prescaler value Pideal can be calculated PRSAC &= 0xF0; as follows: // Set Aux1 prescaler to 1 (F = 12 MHz) Pideal = fAudio In / fbit CRCTRL |= ACE1; // Enable Aux1 clk The real prescaler must be set to an integer value, which 18.5.2 Interrupts should be as close as possible to the ideal prescaler value, The interrupt logic of the AAI combines up to four interrupt to minimize the bit clock error, fbit_error. sources and generates one interrupt request signal to the fbit_error [%] = (fbit - fAudio In/Preal) / fbit × 100 Interrupt Control Unit (ICU). Example: The four interrupt sources are: The audio interface is used to transfer 13-bit linear PCM data for one audio channel at a sample rate of 8k samples per second. The input clock of the audio interface is 12 MHz. Furthermore, the codec requires a minimum bit clock of 256 kHz to operate properly. Therefore, the number of slots per frame must be set to 2 (network mode) although actually only one slot (slot 0) is used. The codec and the audio interface will put their data transmit pins in TRI-STATE mode after the PCM data word has been transferred. The required bit clock rate fbit can be calculated by the following equation: RX FIFO Overrun - ASCR.RXEIP = 1 RX FIFO Almost Full (Warning Level) - ASCR.RXIP = 1 TX FIFO Under run - ASCR.TXEIP = 1 TX FIFO Almost Empty (Warning Level) - ASCR.TXIP=1 In addition to the dedicated input to the ICU for handling these interrupt sources, the Serial Frame Sync (SFS) signal is an input to the MIWU (see Section 13.0), which can be programmed to generate edge-triggered interrupts. fbit = n × fSample × Data Length = 2 × 8 kHz × 16 = 256 kHz 119 www.national.com CP3CN23 The ideal required prescaler value Pideal can be calculated as follows: CP3CN23 Figure 52 shows the interrupt structure of the AAI. event, the read pointer (TRP) will be decremented by 1 (incremented by 15) and the previous data word will be transmitted again. A transmit FIFO underrun is indicated by the TXU bit in the Audio Interface Transmit Status and Control Register (ATSCR). Also, no transmit interrupt will be generated (even if enabled). RXIE RXIP = 1 When the TRP is equal to the TWP and the last access to the FIFO was a write operation (to the ATFR), the FIFO is full. If an additional write to ATFR is performed, a transmit FIFO overrun occurs. This error condition is not prevented by hardware. Software must ensure that no transmit overrun occurs. RXEIE AAI Interrupt RXEIP = 1 TXIE The transmit frame synchronization pulse on the SFS pin and the transmit shift clock on the SCK pin may be generated internally, or they can be supplied by an external source. TXIP = 1 TXEIE 18.5.5 At the receiver, the received data on the SRD pin is shifted into ARSR on the negative edge of SRCLK (or SCK in synchronous mode), following the receive frame sync pulse, SRFS (or SFS in synchronous mode). TXEIP = 1 DS155 Figure 52. AAI Interrupt Structure 18.5.3 Normal Mode In normal mode, each frame sync signal marks the beginning of a new frame and also the beginning of a new slot, since each frame only consists of one slot. All 16 receive and transmit FIFO locations hold data for the same (and only) slot of a frame. If 8-bit data are transferred, only the low byte of each 16-bit FIFO location holds valid data. 18.5.4 Transmit Once the interface has been enabled, transmit transfers are initiated automatically at the beginning of every frame. The beginning of a new frame is identified by a frame sync pulse. Following the frame sync pulse, the data is shifted out from the ATSR to the STD pin on the positive edge of the transmit data shift clock (SCK). DMA Operation Receive DMA Operation When a complete data word has been received through the SRD pin, the new data word is copied to the receive DMA register 0 (ARDR0). A DMA request is asserted when the ARDR0 register is full. If a new data word is received while the ARDR0 register is still full, the ARDR0 register will be overwritten with the new data. FIFO Operation When a complete word has been received, it is transferred to the receive FIFO at the current location of the Receive FIFO Write Pointer (RWP). Then, the RWP is automatically incremented by 1. A read from the Audio Receive FIFO Register (ARFR) results in a read from the receive FIFO at the current location of the Receive FIFO Read Pointer (RRP). After every read operation from the receive FIFO, the RRP is automatically incremented by 1. When a complete data word has been transmitted through the STD pin, a new data word is reloaded from the transmit DMA register 0 (ATDR0). A DMA request is asserted when When the RRP is equal to the RWP and the last access to the ATDR0 register is empty. If a new data word must be the FIFO was a copy operation from the ARFR, the receive transmitted while the ATDR0 register is still empty, the preFIFO is full. When a new complete data word has been shiftvious data will be re-transmitted. ed into ARSR while the receive FIFO was already full, the shift register overruns. In this case, the new data in the FIFO Operation ARSR will not be copied into the FIFO and the RWP will not When a complete data word has been transmitted through be incremented. A receive FIFO overrun is indicated by the the STD pin, a new data word is loaded from the transmit RXO bit in the Audio Interface Receive Status and Control FIFO from the current location of the Transmit FIFO Read Register (ARSCR). No receive interrupt will be generated Pointer (TRP). After that, the TRP is automatically incre(even if enabled). mented by 1. When the RWP is equal to the RRP and the last access to A write to the Audio Transmit FIFO Register (ATFR) results the receive FIFO was a read from the ARFR, a receive FIFO in a write to the transmit FIFO at the current location of the underrun has occurred. This error condition is not prevented Transmit FIFO Write Pointer (TWP). After every write operby hardware. Software must ensure that no receive underation to the transmit FIFO, TWP is automatically incrementrun occurs. ed by 1. The receive frame synchronization pulse on the SRFS pin When the TRP is equal to the TWP and the last access to (or SFS in synchronous mode) and the receive shift clock on the FIFO was a read operation (a transfer to the ATSR), the the SRCLK (or SCK in synchronous mode) may be genertransmit FIFO is empty. When an additional read operation ated internally, or they can be supplied by an external from the FIFO to ATSR is performed (while the FIFO is alsource. ready empty), a transmit FIFO underrun occurs. In this www.national.com 120 Network Mode DMA Operation In network mode, each frame sync signal marks the beginning of new frame. Each frame can consist of up to four slots. The audio interface operates in a similar way to normal mode, however, in network mode the transmitter and receiver can be assigned to specific slots within each frame as described below. 18.5.7 Transmit The transmitter only shifts out data during the assigned slot. During all other slots the STD output is in TRI-STATE mode. DMA Operation When a complete data word has been received through the SRD pin in a slot n, the new data word is transferred to the corresponding receive DMA register n (ARDRn). A DMA request is asserted when the ARDRn register is full. If a new slot n data word is received while the ARDRn register is still full, the ARDRn register will be overwritten with the new data. FIFO Operation When a complete word has been received, it is transferred to the receive FIFO at the current location of the Receive FIFO Write Pointer (RWP). After that, the RWP is automatically incremented by 1. Therefore, data received in the next slot is copied to the next higher FIFO location. When a complete data word has been transmitted through the STD pin, a new data word is reloaded from the corresponding transmit DMA register n (ATDRn). A DMA request A read from the Audio Receive FIFO Register (ARFR) reis asserted when ATDRn is empty. If a new data word must sults in a read from the receive FIFO at the current location be transmitted in a slot n while ATDRn is still empty, the preof the Receive FIFO Read Pointer (RRP). After every read vious slot n data will be retransmitted. operation from the receive FIFO, the RRP is automatically FIFO Operation incremented by 1. When a complete data word has been transmitted through the STD pin, a new data word is reloaded from the transmit FIFO from the current location of the Transmit FIFO Read Pointer (TRP). After that, the TRP is automatically incremented by 1. Therefore, the audio data to be transmitted in the next slot of the frame is read from the next FIFO location. When the RRP is equal to the RWP and the last access to the FIFO was a transfer to the ARFR, the receive FIFO is full. When a new complete data word has been shifted into the ARSR while the receive FIFO was already full, the shift register overruns. In this case, the new data in the ARSR will not be transferred to the FIFO and the RWP will not be incremented. A receive FIFO overrun is indicated by the RXO A write to the Audio Transmit FIFO Register (ATFR) results bit in the Audio Interface Receive Status and Control Regisin a write to the transmit FIFO at the current location of the ter (ARSCR). No receive interrupt will be generated (even if Transmit FIFO Write Pointer (TWP). After every write oper- enabled). ation to the transmit FIFO, the TWP is automatically incre- When the current RWP is equal to the TWP and the last acmented by 1. cess to the receive FIFO was a read from ARFR, a receive When the TRP is equal to the TWP and the last access to FIFO underrun has occurred. This error condition is not prethe FIFO was a read operation (transfer to the ATSR), the vented by hardware. Software must ensure that no receive transmit FIFO is empty. When an additional read operation underrun occurs. from the FIFO to the ATSR is performed (while the FIFO is already empty), a transmit FIFO underrun occurs. In this case, the read pointer (TRP) will be decremented by 1 (incremented by 15) and the previous data word will be transmitted again. A transmit FIFO underrun is indicated by the TXU bit in the Audio Interface Transmit Status and Control Register (ATSCR). No transmit interrupt will be generated (even if enabled). The receive frame synchronization pulse on the SRFS pin (or SFS in synchronous mode) and the receive shift clock on the SRCLK (or SCK in synchronous mode) may be generated internally, or they can be supplied by an external source. If the current TRP is equal to the TWP and the last access to the FIFO was a write operation (to the ATFR), the FIFO is full. If an additional write to the ATFR is performed, a transmit FIFO overrun occurs. This error condition is not prevented by hardware. Software must ensure that no transmit overrun occurs. The word length of the audio data can be selected to be either 8 or 16 bits. In 16-bit mode, all 16 bits of the transmit and receive shift registers (ATSR and ARSR) are used. In 8bit mode, only the lower 8 bits of the transmit and receive shift registers (ATSR and ARSR) are used. 18.6 COMMUNICATION OPTIONS 18.6.1 Data Word Length 18.6.2 Frame Sync Signal The transmit frame synchronization pulse on the SFS pin and the transmit shift clock on the SCK pin may be generat- The audio interface can be configured to use either long or ed internally, or they can be supplied by an external source. short frame sync signals to mark the beginning of a new data frame. If the corresponding Frame Sync Select (FSS) 18.5.8 Receive bit in the Audio Control and Status register is clear, the reThe receive shift register (ARSR) receives data words of all ceive and/or transmit path generates or recognizes short slots in the frame, regardless of the slot assignment of the frame sync pulses with a length of one bit shift clock period. interface. However, only those ARSR contents are trans- When these short frame sync pulses are used, the transfer ferred to the receive FIFO or DMA receive register which of the first data bit or the first slot begins at the first positive were received during the assigned time slots. A receive in- edge of the shift clock after the negative edge on the frame sync pulse. terrupt or DMA request is initiated when this occurs. 121 www.national.com CP3CN23 18.5.6 CP3CN23 If the corresponding Frame Sync Select (FSS) bit in the Audio Control and Status register is set, the receive and/or transmit path generates or recognizes long frame sync pulses. For 8-bit data, the frame sync pulse generated will be 6 bit shift clock periods long, and for 16-bit data the frame sync pulse can be configured to be 13, 14, 15, or 16 bit shift clock periods long. When receiving frame sync, it should be active on the first bit of data and stay active for a least two bit clock periods. It must go low for at least one bit clock period before starting a new frame. When long frame sync pulses are used, the transfer of the first word (first slot) begins at the first positive edge of the bit shift clock after the positive edge of the frame sync pulse. Figure 53 shows examples of short and long frame sync pulses. Bit Shift Clock (SCK/SRCLK) Shift Data (STD/SRD) D0 D1 D2 D3 D4 D5 D6 D7 Some codecs require an inverted frame sync signal. This is available by setting the Inverted Frame Sync bit in the AGCR register. 18.6.3 Audio Control Data The audio interface provides the option to fill a 16-bit slot with up to three data bits if only 13, 14, or 15 PCM data bits are transmitted. These additional bits are called audio control data and are appended to the PCM data stream. The AAI can be configured to append either 1, 2, or 3 audio control bits to the PCM data stream. The number of audio data bits to be used is specified by the 2-bit Audio Control On (ACO) field. If the ACO field is not equal to 0, the specified number of bits are taken from the Audio Control Data field (ACD) and appended to the data stream during every transmit operation. The ADC0 bit is the first bit added to the transmit data stream after the last PCM data bit. Typically, these bits are used for gain control, if this feature is supported by the external PCM codec.Figure 54 shows a 16-bit slot comprising a 13-bit PCM data word plus three audio control bits. Short Frame Sync Pulse Long Frame Sync Pulse DS156 Figure 53. Short and Long Frame Sync Pulses SCK SFS STD D0 D1 D2 D3 D4 D5 D6 D7 D8 D9 D10 D11 D12 ACD2 ACD1 ACD0 13-bit PCM Data Word Audio Control Bits 16-bit Slot DS161 Figure 54. Audio Slot with Audio Control Data www.national.com 122 IOM-2 Mode The IOM-2 interface has the following properties: The AAI can operate in a special IOM-2 compatible mode to allow to connect to an external ISDN controller device. In this IOM-2 mode, the AAI can only operate as a slave, i.e. the bit clock and frame sync signal is provided by the ISDN controller. The AAI only supports the B1 and B2 data of the IOM-2 channel 0, but ignores the other two IOM-2 channels. The AAI handles the B1 and B2 data as one 16-bit data word. Bit clock of 1536 kHz (output from the ISDN controller) Frame repetition rate of 8 ksps (output from the ISDN controller) Double-speed bit clock (one data bit is two bit clocks wide) B1 and B2 data use 8-bit log PCM format Long frame sync pulse Figure 55 shows the structure of an IOM-2 Frame. SFS STD/SRD B1 B2 M C IC1 IC2 M IOM-2 Channel 1 IOM-2 Channel 0 C C IOM-2 Channel 2 IOM-2 Frame (125 µs) DS162 Figure 55. IOM-2 Frame Structure Figure 56 shows the connections between an ISDN controller and a CP3CN23 using a standard IOM-2 interface for the B1/B2 data communication and the external bus interface (IO Expansion) for controlling the ISDN controller. SCK Bit Clock SFS Frame Sync STD Data In SRD Data Out A[7:0] Address D[7:0] Data CP3BT2x ISDN Controller SELIO RD To connect the AAI to an ISDN controller through an IOM-2 compatible interface, the AAI needs to be configured in this way: The AAI must be in IOM-2 Mode (AGCR.IOM2 = 1). The AAI operates in synchronous mode (AGCR.ASS = 0). The AAI operates as a slave, therefore the bit clock and frame sync source selection must be set to external (ACGR.IEFS = 1, ACGR.IEBC = 1). The frame sync length must be set to long frame sync (ACGR.FSS = 1). The data word length must be set to 16-bit (AGCR.DWL = 1). The AAI must be set to normal mode (AGCR.SCS[1:0] = 0). The internal frame rate must be 8 ksps (ACCR = 00BE). 18.6.5 Chip Select Output Enable DS241 Loopback Mode In loopback mode, the STD and SRD pins are internally connected together, so data shifted out through the ATSR register will be shifted into the ARSR register. This mode may be used for development, but it also allows testing the transmit and receive path without external circuitry, for example during Built-In-Self-Test (BIST). Figure 56. CP3CN23/ISDN Controller Connections 123 www.national.com CP3CN23 18.6.4 CP3CN23 18.6.6 18.7 Freeze Mode The audio interface provides a FREEZE input, which allows to freeze the status of the audio interface while a development system examines the contents of the FIFOs and registers. When the FREEZE input is asserted, the audio interface behaves as follows: The receive FIFO or receive DMA registers are not updated with new data. The receive status bits (RXO, RXE, RXF, and RXAF) are not changed, even though the receive FIFO or receive DMA registers are read. The transmit shift register (ATSR) is not updated with new data from the transmit FIFO or transmit DMA registers. The transmit status bits (TXU, TXF, TXE, and TXAE) are not changed, even though the transmit FIFO or transmit DMA registers are written. The time at which these registers are frozen will vary because they operate from a different clock than the one used to generate the freeze signal. www.national.com 124 AUDIO INTERFACE REGISTERS Table 57 Audio Interface Registers Name Address Description ARFR FF FD40h Audio Receive FIFO Register ARDR0 FF FD42h Audio Receive DMA Register 0 ARDR1 FF FD44h Audio Receive DMA Register 1 ARDR2 FF FD46h Audio Receive DMA Register 2 ARDR3 FF FD48h Audio Receive DMA Register 3 ATFR FF FD4Ah Audio Transmit FIFO Register ATDR0 FF FD4Ch Audio Transmit DMA Register 0 ATDR1 FF FD4Eh Audio Transmit DMA Register 1 ATDR2 FF FD50h Audio Transmit DMA Register 2 ATDR3 FF FD52h Audio Transmit DMA Register 3 AGCR FF FD54h Audio Global Configuration Register AISCR FF FD56h Audio Interrupt Status and Control Register ARSCR FF FD58h Audio Receive Status and Control Register ATSCR FF FD5Ah Audio Transmit Status and Control Register ACCR FF FD5Ch Audio Clock Control Register ADMACR FF FD5Eh Audio DMA Control Register Audio Receive FIFO Register (ARFR) 18.7.3 The Audio Receive FIFO register shows the receive FIFO location currently addressed by the Receive FIFO Read Pointer (RRP). The receive FIFO receives 8-bit or 16-bit data from the Audio Receive Shift Register (ARSR), when the ARSR is full. In 8-bit mode, only the lower byte of the ARFR is used, and the upper byte contains undefined data. In 16-bit mode, a 16-bit word is copied from ARSR into the receive FIFO. The CPU bus master has read-only access to the receive FIFO, represented by the ARFR register. After reset, the receive FIFO (ARFR) contains undefined data. 7 The ATFR register shows the transmit FIFO location currently addressed by the Transmit FIFO Write Pointer (TWP). The Audio Transmit Shift Register (ATSR) receives 8-bit or 16-bit data from the transmit FIFO, when the ATSR is empty. In 8-bit mode, only the lower 8-bit portion of the ATSR is used, and the upper byte is ignored (not transferred into the ATSR). In 16-bit mode, a 16-bit word is copied from the transmit FIFO into the ATSR. The CPU bus master has write-only access to the transmit FIFO, represented by the ATFR register. After reset, the transmit FIFO (ATFR) contains undefined data. 7 0 15 8 ARFH 18.7.2 The Audio Receive FIFO Low Byte shows the lower byte of the receive FIFO location currently addressed by the Receive FIFO Read Pointer (RRP). The Audio Receive FIFO High Byte shows the upper byte of the receive FIFO location currently addressed by the Receive FIFO Read Pointer (RRP). In 8-bit mode, ARFH contains undefined data. ATFL ATFH 18.7.4 Audio Receive DMA Register n (ARDRn) The ARDRn register contains the data received within slot n, assigned for DMA support. In 8-bit mode, only the lower 8-bit portion of the ARDRn register is used, and the upper byte contains undefined data. In 16-bit mode, a 16-bit word is transferred from the Audio Receive Shift Register (ARSR) into the ARDRn register. The CPU bus master, typically a DMA controller, has read-only access to the receive DMA registers. After reset, these registers are clear. 7 0 ATDL 15 8 8 ATDH ARDH ARDH Audio Transmit DMA Register n (ATDRn) 7 ARDL ARDL The Audio Transmit Low Byte field represents the lower byte of the transmit FIFO location currently addressed by the Transmit FIFO Write Pointer (TWP). In 16-bit mode, the Audio Transmit FIFO High Byte field represents the upper byte of the transmit FIFO location currently addressed by the Transmit FIFO Write Pointer (TWP). In 8bit mode, the ATFH field is not used. The ATDRn register contains the data to be transmitted in slot n, assigned for DMA support. In 8-bit mode, only the lower 8-bit portion of the ATDRn register is used, and the upper byte is ignored (not transferred into the ATSR). In 16bit mode, the whole 16-bit word is transferred into the ATSR. The CPU bus master, typically a DMA controller, has writeonly access to the transmit DMA registers. After reset, these registers are clear. 0 15 8 ATFH ARFH ARFL 0 ATFL ARFL 15 Audio Transmit FIFO Register (ATFR) The Audio Receive DMA Low Byte field receives the lower byte of the audio data copied from the ARSR. In 16-bit mode, the Audio Receive DMA High Byte field receives the upper byte of the audio data word copied from ARSR. In 8-bit mode, the ARDH register holds undefined data. ATDL ATDH 125 The Audio Transmit DMA Low Byte field holds the lower byte of the audio data. In 16-bit mode, the Audio Transmit DMA High Byte field holds the upper byte of the audio data word. In 8-bit mode, the ATDH field is ignored. www.national.com CP3CN23 18.7.1 CP3CN23 18.7.5 Audio Global Configuration Register (AGCR) IEFS The AGCR register controls the basic operation of the interface. The CPU bus master has read/write access to the AGCR register. After reset, this register is clear. 7 6 5 4 IEBC FSS IEFS 3 SCS 2 1 0 LPB DWL ASS 10 9 8 CTF CRF FSS 15 14 13 CLKEN AAIEN IOM2 ASS DWL LPB SCS 12 11 IFS FSL The Asynchronous/Synchronous Mode Select bit controls whether the audio interface operates in Asynchronous or in Synchronous mode. After reset the ASS bit is clear, so the Synchronous mode is selected by default. 0 – Synchronous mode. 1 – Asynchronous mode. The Data Word Length bit controls whether the transferred data word has a length of 8 or 16 bits. After reset, the DWL bit is clear, so 8bit data words are used by default. 0 – 8-bit data word length. 1 – 16-bit data word length. The Loop Back bit enables the loop back mode. In this mode, the SRD and STD pins are internally connected. After reset the LPB bit is clear, so by default the loop back mode is disabled. 0 – Loop back mode disabled. 1 – Loop back mode enabled. The Slot Count Select field specifies the number of slots within each frame. If the number of slots per frame is equal to 1, the audio interface operates in normal mode. If the number of slots per frame is greater than 1, the interface operates in network mode. After reset all SCS bits are cleared, so by default the audio interface operates in normal mode. IEBC CRF CTF FSL SCS Number of Slots per Frame Mode 00 1 Normal mode 01 2 Network mode FSL Frame Sync Length 10 3 Network mode 00 13 bit clocks 11 4 Network mode 01 14 bit clocks 10 15 bit clocks 11 16 bit clocks IFS www.national.com The Internal/External Frame Sync bit controls, whether the frame sync signal for the receiver and transmitter are generated internally or provided from an external source. After reset, the IEFS bit is clear, so the frame synchronization signals are generated internally by default. 0 – Internal frame synchronization signal. 1 – External frame synchronization signal. The Frame Sync Select bit controls whether the interface (receiver and transmitter) uses long or short frame synchronization signals. After reset the FSS bit is clear, so short frame synchronization signals are used by default. 0 – Short (bit length) frame synchronization signal. 1 – Long (word length) frame synchronization signal. The Internal/External Bit Clock bit controls whether the bit clocks for receiver and transmitter are generated internally or provided from an external source. After reset, the IEBC bit is clear, so the bit clocks are generated internally by default. 0 – Internal bit clock. 1 – External bit clock. The Clear Receive FIFO bit is used to clear the receive FIFO. When this bit is written with a 1, all pointers of the receive FIFO are set to their reset state. After updating the pointers, the CRF bit will automatically be cleared again. 0 – Writing 0 has no effect. 1 – Writing 1 clears the receive FIFO. The Clear Transmit FIFO bit is used to clear the transmit FIFO. When this bit is written with a 1, all pointers of the transmit FIFO are set to their reset state. After updating the pointers, the CTF bit will automatically be cleared again. 0 – Writing 0 has no effect. 1 – Writing 1 clears the transmit FIFO. The Frame Sync Length field specifies the length of the frame synchronization signal, when a long frame sync signal (FSS = 1) and a 16-bit data word length (DWL = 1) are used. If an 8-bit data word length is used, long frame syncs are always 6 bit clocks in length. 126 The Inverted Frame Sync bit controls the polarity of the frame sync signal. 0 – Active-high frame sync signal. 1 – Active-low frame sync signal. The IOM-2 Mode bit selects the normal PCM interface mode or a special IOM-2 mode used to connect to external ISDN controller devices. The AAI can only operate as a slave in the IOM-2 mode, i.e. the bit clock and frame sync signals are provided by the ISDN controller. If the IOM2 bit is clear, the AAI operates in the normal PCM interface mode used to connect to external PCM codecs and other PCM audio devices. 0 – IOM-2 mode disabled. 1 – IOM-2 mode enabled. The AAI Enable bit controls whether the Advanced Audio Interface is enabled. All AAI registers provide read/write access while (CLKEN = 1) AAIEN is clear. The AAIEN bit is clear after reset. 0 – AAI module disabled. 1 – AAI module enabled. The Clock Enable bit controls whether the Advanced Audio Interface clock is enabled. The CLKEN bit must be set to allow access to any AAI register. It must also be set before any other bit of the AGCR can be set. The CLKEN bit is clear after reset. 0 – AAI module clock disabled. 1 – AAI module clock enabled. AAIEN CLKEN 18.7.6 TXIE TXEIE RXIP RXEIP Audio Interrupt Status and Control Register (AISCR) The ASCR register is used to specify the source and the conditions, when the audio interface interrupt is asserted to TXIP the Interrupt Control Unit. It also holds the interrupt pending bits and the corresponding interrupt clear bits for each audio interface interrupt source. The CPU bus master has read/ write access to the ASCR register. After reset, this register is clear. 7 6 5 4 3 2 1 TXEIP 0 TXEIP TXIP RXEIP RXIP TXEIE TXIE RXEIE RXIE 15 12 Reserved 11 10 9 8 TXEIC TXIC RXEIC RXIC RXIC RXIE RXEIE The Receive Interrupt Enable bit controls whether receive interrupts are generated. If the RXIE bit is clear, no receive interrupt will RXEIC be generated. 0 – Receive interrupt disabled. 1 – Receive interrupt enabled. The Receive Error Interrupt Enable bit con- TXIC trols whether receive error interrupts are generated. Setting this bit enables a receive error interrupt, when the Receive Buffer Overrun (RXOR) bit is set. If the RXEIE bit is clear, no TXEIC receive error interrupt will be generated. 0 – Receive error interrupt disabled. 1 – Receive error interrupt enabled. 127 The Transmit Interrupt Enable bit controls whether transmit interrupts are generated. Setting this bit enables a transmit interrupt, when the Transmit Buffer Almost Empty (TXAE) bit is set. If the TXIE bit is clear, no interrupt will be generated. 0 – Transmit interrupt disabled. 1 – Transmit interrupt enabled. The Transmit Error Interrupt Enable bit controls whether transmit error interrupts are generated. Setting this bit to 1 enables a transmit error interrupt, when the Transmit Buffer Underrun (TXUR) bit is set. If the TXEIE bit is clear, no transmit error interrupt will be generated. 0 – Transmit error interrupt disabled. 1 – Transmit error interrupt enabled. The Receive Interrupt Pending bit indicates that a receive interrupt is currently pending. The RXIP bit is cleared by writing a 1 to the RXIC bit. The RXIP bit provides read-only access. 0 – No receive interrupt pending. 1 – Receive interrupt pending. The Receive Error Interrupt Pending bit indicates that a receive error interrupt is currently pending. The RXEIP bit is cleared by writing a 1 to the RXEIC bit. The RXEIP bit provides read-only access. 0 – No receive error interrupt pending. 1 – Receive error interrupt pending. The Transmit Interrupt Pending bit indicates that a transmit interrupt is currently pending. The TXIP bit is cleared by writing a 1 to the TXIC bit. The TXIP bit provides read-only access. 0 – No transmit interrupt pending. 1 – Transmit interrupt pending. Transmit Error Interrupt Pending. This bit indicates that a transmit error interrupt is currently pending. The TXEIP bit is cleared by software by writing a 1 to the TXEIC bit. The TXEIP bit provides read-only access. 0 – No transmit error interrupt pending. 1 – Transmit error interrupt pending. The Receive Interrupt Clear bit is used to clear the RXIP bit. 0 – Writing a 0 to the RXIC bit is ignored. 1 – Writing a 1 clears the RXIP bit. The Receive Error Interrupt Clear bit is used to clear the RXEIP bit. 0 – Writing a 0 to the RXEIC bit is ignored. 1 – Writing a 1 clears the RXEIP bit. The Transmit Interrupt Clear bit is used to clear the TXIP bit. 0 – Writing a 0 to the TXIC bit is ignored. 1 – Writing a 1 clears the TXIP bit. The Transmit Error Interrupt Clear bit is used to clear the TXEIP bit. 0 – Writing a 0 to the TXEIC bit is ignored. 1 – Writing a 1 clears the TXEIP bit. www.national.com CP3CN23 IOM2 CP3CN23 18.7.7 Audio Receive Status and Control Register (ARSCR) The following table shows the slot assignment scheme. The ARSCR register is used to control the operation of the receiver path of the audio interface. It also holds bits which report the current status of the receive FIFO. The CPU bus master has read/write access to the ASCR register. At reset, this register is loaded with 0004h. 7 4 RXSA 15 12 RXFWL RXAF RXF RXE RXO RXSA 3 2 RXO RXE 1 0 RXF RXAF 11 8 RXDSA RXDSA The Receive Buffer Almost Full bit is set when the number of data bytes/words in the receive buffer is equal to the specified warning limit. 0 – Receive FIFO below warning limit. 1 – Receive FIFO is almost full. The Receive Buffer Full bit is set when the receive buffer is full. The RXF bit is set when the RWP is equal to the RRP and the last access was a write to the FIFO. 0 – Receive FIFO is not full. 1 – Receive FIFO full. The Receive Buffer Empty bit is set when the the RRP is equal to the RWP and the last access to the FIFO was a read operation (read from ARDR). 0 – Receive FIFO is not empty. 1 – Receive FIFO is empty. The Receive Overflow bit indicates that a receive shift register has overrun. This occurs, when a completed data word has been shifted RXFWL into ARSR, while the receive FIFO was already full (the RXF bit was set). In this case, the new data in ARSR will not be copied into the FIFO and the RWP will not be incremented. Also, no receive interrupt and DMA request will generated (even if enabled). 0 – No overflow has occurred. 1 – Overflow has occurred. The Receive Slot Assignment field specifies which slots are recognized by the receiver of the audio interface. Multiple slots may be enabled. If the frame consists of less than 4 slots, the RXSA bits for unused slots are ignored. For example, if a frame only consists of 2 slots, RXSA bits 2 and 3 are ignored. www.national.com 128 RXSA Bit Slots Enabled RXSA0 0 RXSA1 1 RXSA2 2 RXSA3 3 After reset the RXSA field is clear, so software must load the correct slot assignment. The Receive DMA Slot Assignment field specifies which slots (audio channels) are supported by DMA. If the RXDSA bit is set for an assigned slot n (RXSAn = 1), the data received within this slot will not be transferred into the receive FIFO, but will instead be written into the corresponding Receive DMA data register (ARDRn). A DMA request n is asserted, when the ARDRn is full and if the RMA bit n is set. If the RXSD bit for a slot is clear, the RXDSA bit is ignored. The following table shows the DMA slot assignment scheme. RXDSA Bit Slots Enabled for DMA RXDSA0 0 RXDSA1 1 RXDSA2 2 RXDSA3 3 The Receive FIFO Warning Level field specifies when a receive interrupt is asserted. A receive interrupt is asserted, when the number of bytes/words in the receive FIFO is greater than the warning level value. An RXFWL value of 0 means that a receive interrupt is asserted if one or more bytes/words are in the RX FIFO. After reset, the RXFWL bit is clear. Audio Transmit Status and Control Register (ATSCR) The ASCR register controls the basic operation of the interface. It also holds bits which report the current status of the audio communication. The CPU bus master has read/write access to the ASCR register. At reset, this register is loaded with F003h. 7 4 TXSA 15 12 TXFWL TXAE TXE TXF TXU TXSA 3 2 TXU TXF 1 0 TXSA Bit Slots Enabled TXSA0 0 TXSA1 1 TXSA2 2 TXSA3 3 TXE TXAE 11 8 TXDSA TXDSA The Transmit FIFO Almost Empty bit is set when the number of data bytes/words in transmit buffer is equal to the specified warning limit. 0 – Transmit FIFO above warning limit. 1 – Transmit FIFO at or below warning limit. The Transmit FIFO Empty bit is set when the transmit buffer is empty. The TXE bit is set to one every time the TRP is equal to the TWP and the last access to the FIFO was read operation (into ATSR). 0 – Transmit FIFO not empty. 1 – Transmit FIFO empty. The Transmit FIFO Full bit is set when the TWP is equal to the TRP and the last access to the FIFO was write operation (write to ATDR). 0 – Transmit FIFO not full. 1 – Transmit FIFO full. The Transmit Underflow bit indicates that the TFWL transmit shift register (ATSR) has underrun. This occurs when the transmit FIFO was already empty and a complete data word has been transferred. In this case, the TRP will be decremented by 1 and the previous data will be retransmitted. No transmit interrupt and no DMA request will be generated (even if enabled). 0 – Transmit underrun occurred. 1 – Transmit underrun did not occur. The Transmit Slot Assignment field specifies during which slots the transmitter is active and drives data through the STD pin. The STD pin is in high impedance state during all other slots. If the frame consists of less than 4 slots, the TXSA bits for unused slots are ignored. For example, if a frame only consists of 2 slots, TXSA bits 2 and 3 are ignored. The following table shows the slot assignment scheme. 129 After reset, the TXSA field is clear, so software must load the correct slot assignment. The Transmit DMA Slot Assignment field specifies which slots (audio channels) are supported by DMA. If the TXDSA bit is set for an assigned slot n (TXSAn = 1), the data to be transmitted within this slot will not be read from the transmit FIFO, but will instead be read from the corresponding Transmit DMA data register (ATDRn). A DMA request n is asserted when the ATDRn is empty. If the TSA bit for a slot is clear, the TXDSA bit is ignored. The following table shows the DMA slot assignment scheme. TXDSA Bit Slots Enabled for DMA TXDSA0 0 TXDSA1 1 TXDSA2 2 TXDSA3 3 The Transmit FIFO Warning Level field specifies when a transmit interrupt is asserted. A transmit interrupt is asserted when the number of bytes or words in the transmit FIFO is equal or less than the warning level value. A TXFWL value of Fh means that a transmit interrupt is asserted if one or more bytes or words are available in the transmit FIFO. At reset, the TXFWL field is loaded with Fh. www.national.com CP3CN23 18.7.8 CP3CN23 18.7.9 Audio Clock Control Register (ACCR) ignored. The following table shows the receive DMA request scheme. The ACCR register is used to control the bit timing of the audio interface. After reset, this register is clear. 7 1 FCPRS 15 RMD DMA Request Condition 0 0000 None CSS 0001 ARDR0 full 0010 ARDR1 full 0011 ARDR0 full or ARDR1 full x1xx Not supported on CP3CN23 8 BCPRS CSS FCPRS BCPRS The Clock Source Select bit selects one out of two possible clock sources for the audio interTMD face. After reset, the CSS bit is clear. 0 – The Auxiliary Clock 1 is used to clock the Audio Interface. 1 – The 48-MHz clock is used to clock the Audio Interface. The Frame Clock Prescaler is used to divide the bit clock to generate the frame clock for the receive and transmit operations. The bit clock is divided by (FCPRS + 1). After reset, the FCPRS field is clear. The maximum allowed bit clock rate to achieve an 8 kHz frame clock is 1024 kHz. This value must be set correctly even if the frame sync is generated externally. The Bit Clock Prescaler is used to divide the audio interface clock (selected by the CSS bit) to generate the bit clock for the receive and transmit operations. The audio interface input clock is divided by (BCPRS + 1). After reset, the BCPRS[7:0] bits are clear. 18.7.10 Audio DMA Control Register (ADMACR) ACD ACO 4 3 TMD 15 13 Reserved RMD 0 RMD 12 11 ACO 10 8 ACD The Receive Master DMA field specify which slots (audio channels) are supported by DMA, i.e. when a DMA request is asserted to the DMA controller. If the RMDn bit is set for an assigned slot n (RXDSAn = 1), a DMA request n is asserted, when the ARDRn is full. If the RXDSAn bit for a slot is clear, the RMDn bit is www.national.com The Transmit Master DMA field specifies which slots (audio channels) are supported by DMA, i.e. when a DMA request is asserted to the DMA controller. If the TMD bit is set for an assigned slot n (TXDSAn = 1), a DMA request n is asserted, when the ATDRn register is empty. If the TXDSA bit for a slot is clear, the TMD bit is ignored. The following table shows the transmit DMA request scheme. TMD DMA Request Condition 0000 None 0001 ATDR0 empty 0010 ATDR1 empty 0011 ATDR0 empty or ATDR1 empty x1xx 1xxx The ADMACR register is used to control the DMA support of the audio interface. In addition, it is used to configure the automatic transmission of the audio control bits. After reset, this register is clear. 7 1xxx 130 Not supported on CP3CN23 The Audio Control Data field is used to fill the remaining bits of a 16-bit slot if only 13, 14, or 15 bits of PCM audio data are transmitted. The Audio Control Output field controls the number of control bits appended to the PCM data word. 00 – No Audio Control bits are appended. 01 – Append ACD0. 10 – Append ACD1:0. 11 – Append ACD2:0. The CVSD/PCM module performs conversion between CVSD data and PCM data, in which the CVSD encoding is as defined in the Bluetooth specification and the PCM encoding may be 8-bit µ-Law, 8-bit A-Law, or 13-bit to 16-bit Linear. The CVSD conversion module operates at a fixed rate of 125 µs (8 kHz) per PCM sample. On the CVSD side, there 2 MHz Clock Input is a read and a write FIFO allowing up to 8 words of data to be read or written at the same time. On the PCM side, there is a double-buffered register requiring data to be read and written every 125 µs. The intended use is to move CVSD data into the module with a CVSD interrupt handler, and to move PCM data with DMA. Figure 57 shows a block diagram of the CVSD to PCM module. Interrupt DMA 16-Bit 8 kHz 16-Bit 64 kHz u/A-Law 16-Bit 8 kHz 1-Bit 64 kHz CVSD Encoder 16-Bit Shift Reg CVSD Decoder 16-Bit Shift Reg Filter Engine 16-Bit u/A-Law 64 kHz 1-Bit 64 kHz Peripheral Bus DS058 Figure 57. CVSD/PCM Converter Block Diagram 19.1 OPERATION Inside the module, a filter engine receives the 8 kHz stream of 16-bit samples and interpolates to generate a 64 kHz The Aux2 clock (generated by the Clock module described stream of 16-bit samples. This goes into a CVSD encoder in Section 11.9) must be configured, because it drives the which converts the data into a single-bit delta stream using CVSD module. Software must set its prescaler to provide a the CVSD parameters as defined by the Bluetooth specifi2 MHz input clock based upon the System Clock (usually cation. There is a similar path that reverses this process 12 MHz). This is done by writing an appropriate divisor to converting the CVSD 64 kHz bit stream into a 64 kHz 16-bit the ACDIV2 field of the PRSAC register. Software must also data stream. The filter engine then decimates this stream enable the Aux2 clock by setting the ACE2 bit within the into an 8 kHz, 16-bit data stream. CRCTRL register. For example: PRSAC &= 0x0f; 19.2 // Set Aux2 prescaler to generate During conversion between CVSD and PCM, any PCM format changes are done automatically depending on whether the PCM data is µ-Law, A-Law, or Linear. In addition to this, a separate function can be used to convert between the various PCM formats as required. Conversion is performed by setting up the control bit CVCTL1.PCMCONV to define the conversion and then writing to the LOGIN and LINEARIN registers and reading from the LOGOUT and LINEAROUT registers. There is no delay in the conversion operation and it does not have to operate at a fixed rate. It will only convert between µ-Law/A-Law and linear, not directly between µLaw and A-Law. (This could easily be achieved by converting between µ-Law and linear and between linear and ALaw.) // 2 MHz (Fsys = 12 MHz) PRSAC |= 0x50; CRCTRL |= ACE2; // Enable Aux2 clk The module converts between PCM data and CVSD data at a fixed rate of 8 kHz per PCM sample. Due to compression, the data rate on the CVSD side is only 4 kHz per CVSD sample. PCM CONVERSIONS If PCM interrupts are enabled (PCMINT is set) every 125 µs (8 kHz) an interrupt will occur and the interrupt handler can operate on some or all of the four audio streams CVSD in, CVSD out, PCM in, and PCM out. Alternatively, a DMA request is issued every 125 µs and the DMA controller is used If a conversion is performed between linear and µ-Law log to move the PCM data between the CVSD/PCM module PCM data, the linear PCM data are treated in the leftand the audio interface. aligned 14-bit linear data format with the two LSBs unused. If CVSD interrupts are enabled, an interrupt is issued when If a conversion is performed between linear and A-Law log either one of the CVSD FIFOs is almost empty or almost full. PCM data, the linear PCM data are treated in the leftOn the PCM data side there is double buffering, and on the aligned 13-bit linear data format with the three LSBs unCVSD side there is an eight word (8 × 16-bit) FIFO for the used. read and write paths. 131 www.national.com CP3CN23 19.0 CVSD/PCM Conversion Module CP3CN23 If the module is only used for PCM conversions, the CVSD been transferred to the audio interface, it will be overwritten clock can be disabled by clearing the CVSD Clock Enable with the new PCM sample. bit (CLKEN) in the control register. If there are only three unread words left, the CVSD In Nearly Empty bit (CVNE) is set and, if enabled (CVSDINT = 1), an 19.3 CVSD CONVERSION interrupt request is generated. The CVSD/PCM converter module transforms either 8-bit logarithmic or 13- to 16-bit linear PCM samples at a fixed If the CVSD In FIFO is empty, the CVSD In Empty bit (CVE) rate of 8 ksps. The CVSD to PCM conversion format must is set and, if enabled (CVSDERRINT = 1), an interrupt rebe specified by the CVSDCONV control bits in the CVSD quest is generated. If the converter core reads from an already empty CVSD In FIFO, the FIFO automatically returns Control register (CVCTRL). a checkerboard pattern to guarantee a minimum level of disThe CVSD algorithm is designed for 2’s complement 16-bit tortion of the audio stream. data and is tuned for best performance with typical voice daINTERRUPT GENERATION ta. Mild distortion will occur for peak signals greater than -6 19.6 dB. The Bluetooth CVSD standard is designed for best per- An interrupt is generated in any of the following cases: formace with typical voice signals: nominaly -6dB with occasional peaks to 0dB rather than full-scale inputs. Distortion When a new PCM sample has been written into the PCMOUT register and the CVCTRL.PCMINT bit is set. of signals greater than -6dB is not considered detrimental to subjective quality tests for voice-band applications and al- When a new PCM sample has been read from the PCMIN register and the CVCTRL.PCMINT bit is set. lows for greater clarity for signals below -6dB. The gain of When the CVSD In FIFO is nearly empty the input device should be tuned with this in mind. (CVSTAT.CVNE = 1) and the CVCTRL.CVSDINT bit is If required, the RESOLUTION field of the CVCTRL register set. can be used to optimize the level of the 16-bit linear input When the CVSD Out FIFO is nearly full data by providing attenuations (right-shifts with sign exten(CVSTAT.CVNF = 1) and the CVCTRL.CVSDINT bit is tion) of 1, 2, or 3 bits. set. Log data is always 8 bit, but to perform the CVSD conver- When the CVSD In FIFO is empty (CVSTAT.CVE = 1) and the CVCTRL.CVSDERRINT bit is set. sion, the log data is first converted to 16-bit 2’s complement linear data. A-law and u-law conversion can also slightly af- When the CVSD Out FIFO is full (CVSTAT.CVF = 1) and the CVCTRL.CVSDERRINT bit is set. fect the optimum gain of the input data. The CVCTRL.RESOLUTION field can be used to attenuate the data if required. Both the CVSD In and CVSD Out FIFOs have a size of If the resolution is not set properly, the audio signal may be 8 × 16 bit (8 words). The warning limits for the two FIFOs is set at 5 words. (The CVSD In FIFO interrupt will occur when clipped or have reduced attenuation. there are 3 words left in the FIFO, and the CVSD Out FIFO 19.4 PCM TO CVSD CONVERSION interrupt will occur when there are 3 or less empty words left The converter core reads out the double-buffered PCMIN in the FIFO.) The limit is set to 5 words because Bluetooth register every 125 µs and writes a new 16-bit CVSD data audio data is transferred in packages composed of 10 or stream into the CVSD Out FIFO every 250 µs. If the PCMIN multiples of 10 bytes. buffer has not been updated with a new PCM sample beDMA SUPPORT tween two reads from the CVSD core, the old PCM data is 19.7 used again to maintain a fixed conversion rate. Once a new The CVSD module can operate with any of four DMA chan16-bit CVSD data stream has been calculated, it is copied nels. Four DMA channels are required for processor independent operation. Both receive and transmit for CVSD into the 8 × 16-bit wide CVSD Out FIFO. If there are only three empty words (16-bit) left in the FIFO, data and PCM data can be enabled individually. The CVSD/ the nearly full bit (CVNF) is set, and, if enabled PCM module asserts a DMA request to the on-chip DMA controller under the following conditions: (CVSDINT = 1), an interrupt request is asserted. If the CVSD Out FIFO is full, the full bit (CVF) is set, and, if The DMAPO bit is set and the PCMOUT register is full, because it has been updated by the converter core with enabled (CVSDERRINT = 1), an interrupt request is asserta new PCM sample. (The DMA controller can read out ed. In this case, the CVSD Out FIFO remains unchanged. one PCM data word from the PCMOUT register.) Within the interrupt handler, the CPU can read out the new The DMAPI bit is set and the PCMIN register is empty, CVSD data. If the CPU reads from an already empty CVSD because it has been read by the converter core. (The Out FIFO, a lockup of the FIFO logic may occur which perDMA controller can write one new PCM data word into sists until the next reset. Software must check the the PCMIN register.) CVOUTST field of the CVSTAT register to read the number The DMACO bit is set and a new 16-bit CVSD data of valid words in the FIFO. Software must not use the CVNF stream has been copied into the CVSD Out FIFO. (The bit as an indication of the number of valid words in the FIFO. DMA controller can read out one 16-bit CVSD data word from the CVSD Out FIFO.) 19.5 CVSD TO PCM CONVERSION The DMACI bit is set and a 16-bit CVSD data stream has The converter core reads from the CVSD In FIFO every been read from the CVSD In FIFO. (The DMA controller 250 µs and writes a new PCM sample into the PCMOUT can write one new 16-bit CVSD data word into the CVSD buffer every 125 µs. If the previous PCM data has not yet In FIFO.) www.national.com 132 Table 58 CVSD/PCM Registers Name Address Description The trigger for DMA may also trigger an interrupt if the corresponding enable bits in the CVCTRL register is set. Therefore care must be taken when setting the desired interrupt and DMA enable bits. The following conditions must be avoided: LINEAROUT FF FC2Eh Linear PCM Data Output Register CVCTRL FF FC30h CVSD Control Register Setting the PCMINT bit and either of the DMAPO or DMAPI bits. Setting the CVSDINT bit and either of the DMACO or DMACI bits. CVSTAT FF FC32h CVSD Status Register 19.8 FREEZE The CVSD/PCM module provides support for an In-SystemEmulator by means of a special FREEZE input. While FREEZE is asserted the module will exhibit the following behavior: CVSD In FIFO will not have data removed by the converter core. CVSD Out FIFO will not have data added by the converter core. PCM Out buffer will not be updated by the converter core. The Clear-on-Read function of the following status bits in the CVSTAT register is disabled: PCMINT CVE CVF 19.9 19.9.1 CVSD Data Input Register (CVSDIN) The CVSDIN register is a 16-bit wide, write-only register. It is used to write CVSD data into the CVSD to PCM converter FIFO. The FIFO is 8 words deep. The CVSDIN bit 15 represents the CVSD data bit at t = t0, CVSDIN bit 0 represents the CVSD data bit at t = t0 - 250 ms. 15 0 CVSDIN 19.9.2 CVSD Data Output Register (CVSDOUT) The CVSDOUT register is a 16-bit wide read-only register. It is used to read the CVSD data from the PCM to CVSD converter. The FIFO is 8 words deep. Reading the CVSDOUT register after reset returns undefined data. 15 CVSD/PCM CONVERTER REGISTERS 0 CVSDOUT Table 58 lists the CVSD/PCM registers. Table 58 CVSD/PCM Registers Name Address Description CVSDIN FF FC20h CVSD Data Input Register CVSDOUT FF FC22h CVSD Data Output Register PCMIN FF FC24h PCM Data Input Register PCMOUT FF FC26h PCM Data Output Register LOGIN FF FC28h Logarithmic PCM Data Input Register LOGOUT FF FC2Ah Logarithmic PCM Data Output Register LINEARIN FF FC2Ch Linear PCM Data Input Register 19.9.3 PCM Data Input Register (PCMIN) The PCMIN register is a 16-bit wide write-only register. It is used to write PCM data to the PCM to CVSD converter via the peripheral bus. It is double-buffered, providing a 125 µs period for an interrupt or DMA request to respond. 15 0 PCMIN 19.9.4 PCM Data Output Register (PCMOUT) The PCMOUT register is a 16-bit wide read-only register. It is used to read PCM data from the CVSD to PCM converter. It is double-buffered, providing a 125 µs period for an interrupt or DMA request to respond. After reset the PCMOUT register is clear. 15 0 PCMOUT 133 www.national.com CP3CN23 The CVSD/PCM module only supports indirect DMA transfers. Therefore, transferring PCM data between the CVSD/ PCM module and another on-chip module requires two bus cycles. CP3CN23 19.9.5 Logarithmic PCM Data Input Register (LOGIN) The LOGIN register is an 8-bit wide write-only register. It is used to receive 8-bit logarithmic PCM data from the peripheral bus and convert it into 13-bit linear PCM data. 7 0 LOGIN 19.9.6 Logarithmic PCM Data Output Register (LOGOUT) The LOGOUT register is an 8-bit wide read-only register. It holds logarithmic PCM data that has been converted from linear PCM data. After reset, the LOGOUT register is clear. 7 0 LOGOUT 19.9.7 Linear PCM Data Input Register (LINEARIN) The LINEARIN register is a 16-bit wide write-only register. The data is left-aligned. When converting to A-law, bits 2:0 are ignored. When converting to µ-law, bits 1:0 are ignored. 15 0 LINEARIN 19.9.8 Linear PCM Data Output Register (LINEAROUT) The LINEAROUT register is a 16-bit wide read-only register. The data is left-aligned. When converting from A-law, bits 2:0 are clear. When converting from µ-law, bits 1:0 are clear. After reset, this register is clear. 15 0 LINEAROUT 19.9.9 CVSD Control Register (CVCTRL) The CVCTRL register is a 16-bit wide, read/write register that controls the mode of operation and of the module’s interrupts. At reset, all implemented bits are cleared. 7 6 DMA PO DMA CI 15 14 13 5 4 3 2 CVSD DMA CVSD PCM ERRCO INT INT INT 12 11 10 1 0 CLK CVEN EN 9 8 Res. RESOLUTION PCMCONV CVSDCONV DMAPI www.national.com CVEN The Module Enable bit enables or disables the CVSD conversion module interface. When the bit is set, the interface is enabled which allows read and write operations to the rest of the module. When the bit is clear, the module is disabled. When the module is disabled the status register CVSTAT will be cleared to its reset state. 0 – CVSD module enabled. 1 – CVSD module disabled. CLKEN The CVSD Clock Enable bit enables the 2MHz clock to the filter engine and CVSD encoders and decoders. 0 – CVSD module clock disabled. 1 – CVSD module clock enabled. PCMINT The PCM Interrupt Enable bit controls generation of the PCM interrupt. If set, this bit enables the PCM interrupt. If the PCMINT bit is clear, the PCM interrupt is disabled. After reset, this bit is clear. 0 – PCM interrupt disabled. 1 – PCM interrupt enabled. CVSDINT The CVSD FIFO Interrupt Enable bit controls generation of the CVSD interrupt. If set, this bit enables the CVSD interrupt that occurs if the CVSD In FIFO is nearly empty or the CVSD Out FIFO is nearly full. If the CVSDINT bit is clear, the CVSD nearly full/nearly empty interrupt is disabled. After reset, this bit is clear. 0 – CVSD interrupt disabled. 1 – CVSD interrupt enabled. CVSDERRINT The CVSD FIFO Error Interrupt Enable bit controls generation of the CVSD error interrupt. If set, this bit enables an interrupt to occur when the CVSD Out FIFO is full or the CVSD In FIFO is empty. If the CVSDERRORINT bit is clear, the CVSD full/empty interrupt is disabled. After reset, this bit is clear. 0 – CVSD error interrupt disabled. 1 – CVSD error interrupt enabled. DMACO The DMA Enable for CVSD Out bit enables hardware DMA control for reading CVSD data from the CVSD Out FIFO. If clear, DMA support is disabled. After reset, this bit is clear. 0 – CVSD output DMA disabled. 1 – CVSD output DMA enabled. DMACI The DMA Enable for CVSD In bit enables hardware DMA control for writing CVSD data into the CVSD In FIFO. If clear, DMA support is disabled. After reset, this bit is clear. 0 – CVSD input DMA disabled. 1 – CVSD input DMA enabled. DMAPO The DMA Enable for PCM Out bit enables hardware DMA control for reading PCM data from the PCMOUT register. If clear, DMA support is disabled. After reset, this bit is clear. 0 – PCM output DMA disabled. 1 – PCM output DMA enabled. 134 The DMA Enable for PCM In bit enables hard- CVNF ware DMA control for writing PCM data into the PCMIN register. If cleared, DMA support is disabled. After reset, this bit is clear. 0 – PCM input DMA disabled. 1 – PCM input DMA enabled. CVSDCONV The CVSD to PCM Conversion Format field specifies the PCM format for CVSD/PCM conversions. After reset, this field is clear. 00 – CVSD <-> 8-bit µ-Law PCM. 01 – CVSD <-> 8-bit A-Law PCM. 10 – CVSD <-> Linear PCM. 11 – Reserved. PCMCONV The PCM to PCM Conversion Format bit selects the PCM format for PCM/PCM conversions. PCMINT 0 – Linear PCM <-> 8-bit µ-Law PCM 1 – Linear PCM <-> 8-bit A-Law PCM RESOLUTION The Linear PCM Resolution field specifies the attenuation of the PCM data for the linear PCM to CVSD conversions by right shifting and sign extending the data. This affects the log PCM data as well as the linear PCM data. The log data is converted to either left-justified CVE zero-stuffed 13-bit (A-law) or 14-bit (u-law). The RESOLUTION field can be used to compensate for any change in average levels resulting from this conversion. After reset, these two bits are clear. 00 – No shift. 01 – 1-bit attentuation. 10 – 2-bit attentuation. 11 – 3-bit attentuation. 19.9.10 CVSD Status Register (CVSTAT) The CVSTAT register is a 16-bit wide, read-only register that holds the status information of the CVSD/PCM module. At reset, and if the CVCTL1.CVEN bit is clear, all implemented bits are cleared. 7 5 CVINST 4 CVF 15 3 2 0 CVE PCMINT CVNF CVNE 11 Reserved 1 CVF 10 8 CVOUTST CVINST CVNE The CVSD In FIFO Nearly Empty bit indicates when only three CVSD data words are left in the CVSD In FIFO, so new CVSD data should be written into the CVSD In FIFO. If the CVSDINT bit is set, an interrupt will be asserted CVOUTST when the CVNE bit is set. If the DMACI bit is set, a DMA request will be asserted when this bit is set. The CVNE bit is cleared when the CVSTAT register is read. 0 – CVSD In FIFO is not nearly empty. 1 – CVSD In FIFO is nearly empty. 135 The CVSD Out FIFO Nearly Full bit indicates when only three empty word locations are left in the CVSD Out FIFO, so the CVSD Out FIFO should be read. If the CVSDINT bit is set, an interrupt will be asserted when the CVNF bit is set. If the DMACO bit is set, a DMA request will be asserted when this bit is set. Software must not rely on the CVNF bit as an indicator of the number of valid words in the FIFO. Software must check the CVOUTST field to read the number of valid words in the FIFO. The CVNF bit is cleared when the CVSTAT register is read. 0 – CVSD Out FIFO is not nearly full. 1 – CVSD Out FIFO is nearly full. The PCM Interrupt bit set indicates that the PCMOUT register is full and needs to be read or the PCMIN register is empty and needs to be loaded with new PCM data. The PCMINT bit is cleared when the CVSTAT register is read, unless the device is in FREEZE mode. 0 – PCM does not require service. 1 – PCM requires loading or unloading. The CVSD In FIFO Empty bit indicates when the CVSD In FIFO has been read by the CVSD converter while the FIFO was already empty. If the CVSDERRORINT bit is set, an interrupt will be asserted when the CVE bit is set. The CVE bit is cleared when the CVSTAT register is read, unless the device is in FREEZE mode. 0 – CVSD In FIFO has not been read while empty. 1 – CVSD In FIFO has been read while empty. The CVSD Out FIFO Full bit set indicates whether the CVSD Out FIFO has been written by the CVSD converter while the FIFO was already full. If the CVSDERRORINT bit is set, an interrupt will be asserted when the CVF bit is set. The CVF bit is cleared when the CVSTAT register is read, unless the device is in FREEZE mode. 0 – CVSD Out FIFO has not been written while full. 1 – CVSD Out FIFO has been written while full. The CVSD In FIFO Status field reports the current number of empty 16-bit word locations in the CVSD In FIFO. When the FIFO is empty, the CVINST field will read as 111b. When the FIFO holds 7 or 8 words of data, the CVINST field will read as 000b. CVSD Out FIFO Status field reports the current number of valid 16-bit CVSD data words in the CVSD Out FIFO. When the FIFO is empty, the CVOUTST field will read as 000b. When the FIFO holds 7 or 8 words of data, the CVOUTST field will read as 111b. www.national.com CP3CN23 DMAPI CP3CN23 20.0 UART Modules The CP3CN23 provides four UART modules. Each UART module is a full-duplex Universal Asynchronous Receiver/ Transmitter that supports a wide range of software-programmable baud rates and data formats. It handles automatic parity generation and several error detection schemes. All UART modules offer the following features: Full-duplex double-buffered receiver/transmitter Asynchronous operation Programmable baud rate Programmable framing formats: 7, 8, or 9 data bits; even, odd, or no parity; one or two stop bits (mark or space) Hardware parity generation for data transmission and parity check for data reception Interrupts on “transmit ready” and “receive ready” conditions, separately enabled Software-controlled break transmission and detection Internal diagnostic capability Automatic detection of parity, framing, and overrun errors One module, UART0, offers the following additional features: Synchronous operation using the CKX external clock pin Hardware flow control (CTS and RTS signals) DMA capability mode of operation, clock source, and type of parity used. The error detection circuit generates parity bits and checks for parity, framing, and overrun errors. The Flow Control Logic block provides the capability for hardware handshaking between the UART and a peripheral device. When the peripheral device needs to stop the flow of data from the UART, it de-asserts the clear-to-send (CTS) signal which causes the UART to pause after sending the current frame (if any). The UART asserts the ready-to-send (RTS) signal to the peripheral when it is ready to send a character. 20.2 UART OPERATION The UART has two basic modes of operation: synchronous and asynchronous. Synchronous mode is only supported for the UART0 module. In addition, there are two specialpurpose modes, called attention and diagnostic. This section describes the operating modes of the UART. 20.2.1 Asynchronous Mode The asynchronous mode of the UART enables the device to communicate with other devices using just two communication signals: transmit and receive. In asynchronous mode, the transmit shift register (TSFT) and the transmit buffer (UnTBUF) double-buffer the data for transmission. To transmit a character, a data byte is loaded 20.1 FUNCTIONAL OVERVIEW in the UnTBUF register. The data is then transferred to the Figure 58 is a block diagram of the UART module showing TSFT register. While the TSFT register is shifting out the the basic functional units in the UART: current character (LSB first) on the TXD pin, the UnTBUF register is loaded by software with the next byte to be trans Transmitter mitted. When TSFT finishes transmission of the last stop bit Receiver of the current frame, the contents of UnTBUF are trans Baud Rate Generator ferred to the TSFT register and the Transmit Buffer Empty Control and Error Detection bit (UTBE) is set. The UTBE bit is automatically cleared by The Transmitter block consists of an 8-bit transmit shift regthe UART when software loads a new character into the ister and an 8-bit transmit buffer. Data bytes are loaded in UnTBUF register. During transmission, the UXMIP bit is set parallel from the buffer into the shift register and then shifted high by the UART. This bit is reset only after the UART has out serially on the TXD pin. sent the last stop bit of the current character and the UnTThe Receiver block consists of an 8-bit receive shift register BUF register is empty. The UnTBUF register is a read/write and an 8-bit receive buffer. Data is received serially on the register. The TSFT register is not software accessible. RXD pin and shifted into the shift register. Once eight bits In asynchronous mode, the input frequency to the UART is have been received, the contents of the shift register are 16 times the baud rate. In other words, there are 16 clock transferred in parallel to the receive buffer. cycles per bit time. In asynchronous mode, the baud rate The Transmitter and Receiver blocks both contain exten- generator is always the UART clock source. sions for 9-bit data transfers, as required by the 9-bit and The receive shift register (RSFT) and the receive buffer (Unloopback operating modes. RBUF) double buffer the data being received. The UART reThe Baud Rate Generator generates the clock for the syn- ceiver continuously monitors the signal on the RXD pin for a chronous and asynchronous operating modes. It consists of low level to detect the beginning of a start bit. On sensing two registers and a two-stage counter. The registers are this low level, the UART waits for seven input clock cycles used to specify a prescaler value and a baud rate divisor. and samples again three times. If all three samples still inThe first stage of the counter divides the UART clock based dicate a valid low, then the receiver considers this to be a on the value of the programmed prescaler to create a slower valid start bit, and the remaining bits in the character frame clock. The second stage of the counter creates the baud are each sampled three times, around the mid-bit position. rate clock by dividing the output of the first stage based on For any bit following the start bit, the logic value is found by the programmed baud rate divisor. majority voting, i.e. the two samples with the same value deThe Control and Error Detection block contains the UART fine the value of the data bit. Figure 59 illustrates the procontrol registers, control logic, error detection circuit, parity cess of start bit detection and bit sampling. generator/checker, and interrupt generation logic. The control registers and control logic determine the data format, www.national.com 136 of the RSFT register are copied into the UnRBUF register and the Receive Buffer Full bit (URBF) is set. The URBF bit is automatically cleared when software reads the character from the URBUF register. The RSFT register is not software accessible. Serial data input on the RXD pin is shifted into the RSFT register. On receiving the complete character, the contents Transmitter TXD Baud Clock RTS Flow Control Logic System Clock Internal Bus CTS Control and Error Detection Baud Rate Generator CKX Parity Generator/Checker Baud Clock Receiver RXD DS060 Figure 58. 16 1 2 3 4 5 6 UART Block Diagram 7 8 Sample 9 10 11 12 13 14 15 1 2 1 Sample DATA (LSB) STARTBIT 16 16 3 4 5 6 7 8 9 10 11 12 13 14 15 16 1 Sample DATABIT DS061 Figure 59. UART Asynchronous Communication 137 www.national.com CP3CN23 Data bits are sensed by taking a majority vote of three samples latched near the midpoint of each baud (bit time). Normally, the position of the samples within the baud is determined automatically, but software can override the automatic selection by setting the USMD bit in the UnMDSL2 register and programming the UnSPOS register. CP3CN23 20.2.2 Synchronous Mode 20.2.3 The synchronous mode of the UART enables the device to communicate with other devices using three communication signals: transmit, receive, and clock. In this mode, data bits are transferred synchronously with the UART clock signal. Data bits are transmitted on the rising edges and received on the falling edges of the clock signal, as shown in Figure 60. Data bytes are transmitted and received least significant bit (LSB) first. Attention Mode The Attention mode is available for networking this device with other processors. This mode requires the 9-bit data format with no parity. The number of start bits and number of stop bits are programmable. In this mode, two types of 9-bit characters are sent on the network: address characters consisting of 8 address bits and a 1 in the ninth bit position and data characters consisting of 8 data bits and a 0 in the ninth bit position. While in Attention mode, the UART receiver monitors the communication flow but ignores all characters until an address character is received. On receiving an address character, the contents of the receive shift register are copied to the receive buffer. The URBF bit is set and an interrupt (if enabled) is generated. The UATN bit is automatically cleared, and the UART begins receiving all subsequent characters. Software must examine the contents of the URBUF register and respond by accepting the subsequent characters (by leaving the UATN bit clear) or waiting for the next address character (by setting the UATN bit again). CKX TDX RDX The operation of the UART transmitter is not affected by the selection of this mode. The value of the ninth bit to be transmitted is programmed by setting or clearing the UXB9 bit in the UART Frame Select register. The value of the ninth bit received is read from URB9 in the UART Status Register. Sample Input DS062 Figure 60. UART Synchronous Communication In synchronous mode, the transmit shift register (TSFT) and the transmit buffer (UnTBUF) double-buffer the data for transmission. To transmit a character, a data byte is loaded in the UnTBUF register. The data is then transferred to the TSFT register. The TSFT register shifts out one bit of the current character, LSB first, on each rising edge of the clock. While the TSFT is shifting out the current character on the TXD pin, the UnTBUF register may be loaded by software with the next byte to be transmitted. When the TSFT finishes transmission of the last stop bit within the current frame, the contents of UnTBUF are transferred to the TSFT register and the Transmit Buffer Empty bit (UTBE) is set. The UTBE bit is automatically reset by the UART when software loads a new character into the UnTBUF register. During transmission, the UXMIP bit is set by the UART. This bit is cleared only after the UART has sent the last frame bit of the current character and the UnTBUF register is empty. 20.2.4 Diagnostic Mode The Diagnostic mode is available for testing of the UART. In this mode, the TXD and RXD pins are internally connected together, and data shifted out of the transmit shift register is immediately transferred to the receive shift register. This mode supports only the 9-bit data format with no parity. The number of start and stop bits is programmable. 20.2.5 Frame Format Selection The format shown in Figure 61 consists of a start bit, seven data bits (excluding parity), and one or two stop bits. If parity bit generation is enabled by setting the UPEN bit, a parity bit is generated and transmitted following the seven data bits. The receive shift register (RSFT) and the receive buffer (URBUF) double-buffer the data being received. Serial data received on the RXD pin is shifted into the RSFT register on the first falling edge of the clock. Each subsequent falling edge of the clock causes an additional bit to be shifted into the RSFT register. The UART assumes a complete character has been received after the correct number of rising edges on CKX (based on the selected frame format) have been detected. On receiving a complete character, the contents of the RSFT register are copied into the UnRBUF register and the Receive Buffer Full bit (URBF) is set. The URBF bit is automatically cleared when software reads the character from the UnRBUF register. 1 Start Bit 7-Bit Data 1a Start Bit 7-Bit Data 1b Start Bit 7-Bit Data PA 1c Start Bit 7-Bit Data PA 1S 2S 1S 2S DS063 Figure 61. 7-Bit Data Frame Options The format shown in Figure 62 consists of one start bit, The transmitter and receiver may be clocked by either an eight data bits (excluding parity), and one or two stop bits. If external source provided to the CKX pin or the internal baud parity bit generation is enabled by setting the UPEN bit, a rate generator. In the latter case, the clock signal is placed on the CKX pin as an output. www.national.com 138 2 Start Bit 2a Start Bit 2b Start Bit 8-Bit Data PA 2c Start Bit 8-Bit Data PA 8-Bit Data Prescaler Select Prescaler Factor 01011 6 01100 6.5 01101 7 01110 7.5 01111 8 10000 8.5 10001 9 10010 9.5 10011 10 10100 10.5 10101 11 10110 11.5 10111 12 11000 12.5 11001 13 11010 13.5 11011 14 11100 14.5 11101 15 11110 15.5 11111 16 1S 8-Bit Data 2S 1S 2S DS064 Figure 62. 8-Bit Data Frame Options The format shown in Figure 63 consists of one start bit, nine data bits, and one or two stop bits. This format also supports the UART attention feature. When operating in this format, all eight bits of UnTBUF and UnRBUF are used for data. The ninth data bit is transmitted and received using two bits in the control registers, called UXB9 and URB9. Parity is not generated or verified in this mode. 3 3a Start Bit 9-Bit Data Start Bit 9-Bit Data 1S 2S DS065 Figure 63. 9-bit Data Frame Options 20.2.6 Baud Rate Generator The Baud Rate Generator creates the basic baud clock from the System Clock. The System Clock is passed through a two-stage divider chain consisting of a 5-bit baud rate prescaler (UnPSC) and an 11-bit baud rate divisor (UnDIV). The relationship between the 5-bit prescaler select (UnPSC) setting and the prescaler factors is shown in Table 59. Table 59 Prescaler Factors Prescaler Select Prescaler Factor 00000 No clock 00001 1 00010 1.5 00011 2 00100 2.5 00101 3 00110 3.5 00111 4 01000 4.5 01001 5 01010 5.5 A prescaler factor of zero corresponds to “no clock.” The “no clock” condition is the UART power down mode, in which the UART clock is turned off to reduce power consumption. Software must select the “no clock” condition before entering a new baud rate. Otherwise, it could cause incorrect data to be received or transmitted. The UnPSR register must contain a value other than zero when an external clock is used at CKX. 20.2.7 Interrupts The UART is capable of generating interrupts on: Receive Buffer Full Receive Error Transmit Buffer Empty 139 www.national.com CP3CN23 Table 59 Prescaler Factors (Continued) parity bit is generated and transmitted following the eight data bits. CP3CN23 Figure 64 shows a diagram of the interrupt sources and associated enable bits. UEEI UFE UDOE UERR RX Interrupt UPE UERI URBF UETI TX Interrupt UTBE UEFCI FC Interrupt UDCTS DS066 Figure 64. UART Interrupts The interrupts can be individually enabled or disabled using the Enable Transmit Interrupt (UETI), Enable Receive Interrupt (UERI), and Enable Receive Error Interrupt (UEER) bits in the UnICTRL register. 20.2.8 DMA Support The UART module can operate with one or two DMA channels. Two DMA channels must be used for processor-independent full-duplex operation. Both receive and transmit DMA can be enabled simultaneously. A transmit interrupt is generated when both the UTBE and UETI bits are set. To remove this interrupt, software must ei- If transmit DMA is enabled (the UETD bit is set), the UART ther disable the interrupt by clearing the UETI bit or write to generates a DMA request when the UTBE bit changes state the UnTBUF register (which clears the UTBE bit). from clear to set. Enabling transmit DMA automatically disA receive interrupt is generated on these conditions: ables transmit interrupts, without regard to the state of the Both the URBF and UERI bits are set. To remove this in- UETI bit. terrupt, software must either disable the interrupt by clearing the UERI bit or read from the URBUF register (which clears the URBF bit). Both the UERR and the UEEI bits are set. To remove this interrupt, software must either disable the interrupt by clearing the UEEI bit or read the UnSTAT register (which clears the UERR bit). If receive DMA is enabled (the UERD bit is set), the UART generates a DMA request when the URBF bit changes state from clear to set. Enabling receive DMA automatically disables receive interrupts, without regard to the state of the UERI bit. However, receive error interrupts should be enabled (the UEEI bit is set) to allow detection of receive errors when DMA is used. A flow control interrupt is generated when both the UDCTS and the UEFCI bits are set. To remove this interrupt, software must either disable the interrupt by clearing the UEFCI bit or reading the UnICTRL register (which clears the UDCTS bit). 20.2.9 In addition to the dedicated inputs to the ICU for UART interrupts, the UART receive (RXD) and Clear To Send (CTS) signals are inputs to the MIWU (see Section 13.0), which can be programmed to generate edge-triggered interrupts. www.national.com Break Generation and Detection A line break is generated when the UBRK bit is set in the UnMDSL1 register. The TXD line remains low until the program resets the UBRK bit. A line break is detected if RXD remains low for 10 bit times or longer after a missing stop bit is detected. 20.2.10 Parity Generation and Detection Parity is only generated or checked with the 7-bit and 8-bit data formats. It is not generated or checked in the diagnostic loopback mode, the attention mode, or in normal mode with the 9-bit data format. Parity generation and checking are enabled and disabled using the PEN bit in the UnFRS register. The UPSEL bits in the UnFRS register are used to select odd, even, or no parity. 140 UART REGISTERS Table 60 Software interacts with the UART modules by accessing the UART registers, as listed in Table 60. Table 60 UART Registers Name U0RBUF U0TBUF U0PSR U0BAUD U0FRS U0MDSL1 U0STAT U0ICTRL U0OVR U0MDSL2 U0SPOS U1RBUF U1TBUF U1PSR U1BAUD U1FRS U1MDSL1 U1STAT U1ICTRL U1OVR Address Description FF F202h UART0 Receive Data Buffer FF F200h UART0 Transmit Data Buffer FF F20Eh UART0 Baud Rate Prescaler FF F20Ch UART0 Baud Rate Divisor FF F208h UART0 Frame Select Register FF F20Ah UART0 Mode Select Register 1 FF F206h UART0 Status Register FF F204h UART0 Interrupt Control Register FF F210h UART0 Oversample Rate Register FF F212h UART0 Mode Select Register 2 FF F214h UART0 Sample Position Register FF F222h UART1 Receive Data Buffer FF F220h UART1 Transmit Data Buffer FF F22Eh UART1 Baud Rate Prescaler FF F22Ch UART1 Baud Rate Divisor FF F228h UART1 Frame Select Register FF F22Ah UART1 Mode Select Register 1 FF F226h UART1 Status Register FF F224h UART1 Interrupt Control Register FF F230h UART1 Oversample Rate Register 141 UART Registers Name Address Description U1MDSL2 FF F232h UART1 Mode Select Register 2 U1SPOS FF F234h UART1 Sample Position Register U2RBUF FF F242h UART2 Receive Data Buffer U2TBUF FF F240h UART2 Transmit Data Buffer U2PSR FF F24Eh UART2 Baud Rate Prescaler U2BAUD FF F24Ch UART2 Baud Rate Divisor U2FRS FF F248h UART2 Frame Select Register U2MDSL1 FF F24Ah UART2 Mode Select Register 1 U2STAT FF F246h UART2 Status Register U2ICTRL FF F244h UART2 Interrupt Control Register U2OVR FF F250h UART2 Oversample Rate Register U2MDSL2 FF F252h UART2 Mode Select Register 2 U2SPOS FF F254h UART2 Sample Position Register U3RBUF FF F262h UART3 Receive Data Buffer U3TBUF FF F260h UART3 Transmit Data Buffer U3PSR FF F26Eh UART3 Baud Rate Prescaler U3BAUD FF F26Ch UART3 Baud Rate Divisor U3FRS FF F268h UART3 Frame Select Register U3MDSL1 FF F26Ah UART3 Mode Select Register 1 U3STAT FF F266h UART3 Status Register U3ICTRL FF F264h UART3 Interrupt Control Register www.national.com CP3CN23 20.3 CP3CN23 Table 60 UART Registers 20.3.4 Name Address Description U3OVR FF F270h UART3 Oversample Rate Register U3MDSL2 FF F272h UART3 Mode Select Register 2 FF F274h UART3 Sample Position Register U3SPOS 20.3.1 The UnBAUD register is a byte-wide, read/write register that contains the lower eight bits of the baud rate divisor. The register contents are unknown at power-up and are left unchanged by a reset operation. The register format is shown below. 7 0 UDIV7:0 UDIV7:0 UART Receive Data Buffer (UnRBUF) The UnRBUF register is a byte-wide, read/write register used to receive each data byte. 7 0 URBUF 20.3.2 20.3.5 UART Transmit Data Buffer (UnTBUF) The UnTBUF register is a byte-wide, read/write register used to transmit each data byte. 7 7 0 UCHAR The UnPSR register is a byte-wide, read/write register that contains the 5-bit clock prescaler and the upper three bits of the baud rate divisor. This register is cleared upon reset. The register format is shown below. 3 UPSC UPSC UDIV10:8 2 0 USTP UDIV10:8 The Prescaler field specifies the prescaler value used for dividing the System Clock in the UXB9 first stage of the two-stage divider chain. For the prescaler factors corresponding to each 5bit value, see Table 59. The Baud Rate Divisor field holds the three most significant bits (bits 10, 9, and 8) of the UART baud rate divisor used in the second UPSEL stage of the two-stage divider chain. The remaining bits of the baud rate divisor are held in the UnBAUD register. www.national.com UART Frame Select Register (UnFRS) 6 Reserved UPEN UART Baud Rate Prescaler (UnPSR) 7 The Baud Rate Divisor field holds the eight lowest-order bits of the UART baud rate divisor used in the second stage of the two-stage divider chain. The three most significant bits are held in the UnPSR register. The divisor value used is (UDIV[10:0] + 1). The UnFRS register is a byte-wide, read/write register that controls the frame format, including the number of data bits, number of stop bits, and parity type. This register is cleared upon reset. The register format is shown below. UnTBUF 20.3.3 UART Baud Rate Divisor (UnBAUD) 142 5 4 UPSEL 3 2 UXB9 USTP 1 0 UCHAR The Character Frame Format field selects the number of data bits per frame, not including the parity bit, as follows: 00 – 8 data bits per frame. 01 – 7 data bits per frame. 10 – 9 data bits per frame. 11 – Loop-back mode, 9 data bits per frame. The Stop Bits bit specifies the number of stop bits transmitted in each frame. If this bit is 0, one stop bit is transmitted. If this bit is 1, two stop bits are transmitted. 0 – One stop bit per frame. 1 – Two stop bits per frame. The Transmit 9th Data Bit holds the value of the ninth data bit, either 0 or 1, transmitted when the UART is configured to transmit nine data bits per frame. It has no effect when the UART is configured to transmit seven or eight data bits per frame. The Parity Select field selects the treatment of the parity bit. When the UART is configured to transmit nine data bits per frame, the parity bit is omitted and the UPSEL field is ignored. 00 – Odd parity. 01 – Even parity. 10 – No parity, transmit 1 (mark). 11 – No parity, transmit 0 (space). 20.3.6 The Parity Enable bit enables or disables parity generation and parity checking. When the UART is configured to transmit nine data bits per frame, there is no parity bit and the UnPEN bit is ignored. 0 – Parity generation and checking disabled. 1 – Parity generation and checking enabled. UART Mode Select Register 1 (UnMDSL1) 6 5 4 3 2 1 The Enable Receive DMA bit controls whether DMA is used for UART receive operations. Enabling receive DMA automatically disables receive interrupts, without regard to the state of the UERI bit. Receive error interrupts are unaffected by the UERD bit. 0 – Receive DMA disabled. 1 – Receive DMA enabled. The Flow Control Enable bit controls whether flow control interrupts are enabled. 0 – Flow control interrupts disabled. 1 – Flow control interrupts enabled. The Ready To Send bit directly controls the state of the RTS output. 0 – RTS output is high. 1 – RTS output is low. UFCE The UnMDSL1 register is a byte-wide, read/write register that selects the clock source, synchronization mode, attention mode, and line break generation. This register is cleared at reset. The register format is shown below. 7 UERD URTS 0 URTS UFCE UERD UETD UCKS UBRK UATN UMOD 20.3.7 UMOD UATN UBRK UCKS UETD The Mode bit selects between synchronous and asynchronous mode. Synchronous mode is only available for the UART0 module. 0 – Asynchronous mode. 1 – Synchronous mode. The Attention Mode bit is used to enable Attention mode. When set, this bit selects the attention mode of operation for the UART. When clear, the attention mode is disabled. The hardware clears this bit after an address frame is received. An address frame is a 9-bit character with a 1 in the ninth bit position. 0 – Attention mode disabled. 1 – Attention mode enabled. The Force Transmission Break bit is used to force the TXD output low. Setting this bit to 1 causes the TXD pin to go low. TXD remains low until the UBRK bit is cleared by software. 0 – Normal operation. 1 – TXD pin forced low. The Synchronous Clock Source bit controls the clock source when the UART operates in the synchronous mode (UMOD = 1). This functionality is only available for the UART0 module. If the UCKS bit is set, the UART operates from an external clock provided on the CKX pin. If the UCKS bit is clear, the UART operates from the baud rate clock produced by the UART on the CKX pin. This bit is ignored when the UART operates in the asynchronous mode. 0 – Internal baud rate clock is used. 1 – External clock is used. The Enable Transmit DMA bit controls whether DMA is used for UART transmit operations. Enabling transmit DMA automatically disables transmit interrupts, without regard to the state of the UETI bit. 0 – Transmit DMA disabled. 1 – Transmit DMA enabled. UART Status Register (UnSTAT) The UnSTAT register is a byte-wide, read-only register that contains the receive and transmit status bits. This register is cleared upon reset. Any attempt by software to write to this register is ignored. The register format is shown below. 7 Res. UPE UFE UDOE UERR 143 6 5 4 3 2 1 0 UXMIP URB9 UBKD UERR UDOE UFE UPE The Parity Error bit indicates whether a parity error is detected within a received character. This bit is automatically cleared by the hardware when the UnSTAT register is read. 0 – No parity error occurred. 1 – Parity error occurred. The Framing Error bit indicates whether the UART fails to receive a valid stop bit at the end of a frame. This bit is automatically cleared by the hardware when the UnSTAT register is read. 0 – No framing error occurred. 1 – Framing error occurred. The Data Overrun Error bit is set when a new character is received and transferred to the UnRBUF register before software has read the previous character from the UnRBUF register. This bit is automatically cleared by the hardware when the UnSTAT register is read. 0 – No receive overrun error occurred. 1 – Receive overrun error occurred. The Error Status bit indicates when a parity, framing, or overrun error occurs (any time that the UPE, UFE, or UDOE bit is set). It is automatically cleared by the hardware when the UPE, UFE, and UDOE bits are all 0. 0 – No receive error occurred. 1 – Receive error occurred. www.national.com CP3CN23 UPEN CP3CN23 UBKD The Break Detect bit indicates when a line break condition occurs. This condition is detected if RXD remains low for at least ten bit times after a missing stop bit has been detected at the end of a frame. The hardware automatically clears the UBKD bit on reading the UnSTAT register, but only if the break condition on RXD no longer exists. If reading the UnSTAT register does not clear the UBKD bit because the break is still actively driven on the line, the hardware clears the bit as soon as the break condition no longer exists (when the RXD input returns to a high level). 0 – No break condition occurred. 1 – Break condition occurred. The Received 9th Data Bit holds the ninth data bit, when the UART is configured to operate in the 9-bit data format. The Transmit In Progress bit indicates when the UART is transmitting. The hardware sets this bit when the UART is transmitting data and clears the bit at the end of the last frame bit. 0 – UART is not transmitting. 1 – UART is transmitting. URB9 UXMIP 20.3.8 UEFCI UETI UERI UEEI UART Interrupt Control Register (UnICTRL) The UnICTRL register is a byte-wide register that contains the receive and transmit interrupt status bits (read-only bits) and the interrupt enable bits (read/write bits). The register is initialized to 01h at reset. The register format is shown below. 7 UCTS 6 5 4 3 2 1 20.3.9 The Clear To Send bit indicates the state on the CTS input. This functionality is only available for the UART0 module. 0 – CTS input is high. 1 – CTS input is low. The Enable Flow Control Interrupt bit controls whether a flow control interrupt is generated when the UDCTS bit changes from clear to set. This functionality is only available for the UART0 module. 0 – Flow control interrupt disabled. 1 – Flow control interrupt enabled. The Enable Transmitter Interrupt bit, when set, enables generation of an interrupt when the hardware sets the UTBE bit. 0 – Transmit buffer empty interrupt disabled. 1 – Transmit buffer empty interrupt enabled. The Enable Receiver Interrupt bit, when set, enables generation of an interrupt when the hardware sets the URBF bit. 0 – Receive buffer full interrupt disabled. 1 – Receive buffer full interrupt enabled. The Enable Receive Error Interrupt bit, when set, enables generation of an interrupt when the hardware sets the UERR bit in the UnSTAT register. 0 – Receive error interrupt disabled. 1 – Receive error interrupt enabled. UART Oversample Rate Register (UnOVR) The UnOVR register is a byte-wide, read/write register that specifies the oversample rate. At reset, the UnOVR register is cleared. The register format is shown below. 0 UEEI UERI UETI UEFCI UCTS UDCTS URBF UTBE 7 4 Reserved UTBE URBF UDCTS The Transmit Buffer Empty bit is set by hardware when the UART transfers data from the UOVSR UnTBUF register to the transmit shift register for transmission. It is automatically cleared by the hardware on the next write to the UnTBUF register. 0 – Transmit buffer is loaded. 1 – Transmit buffer is empty. The Receive Buffer Full bit is set by hardware when the UART has received a complete data frame and has transferred the data from the receive shift register to the UnRBUF register. It is automatically cleared by the hardware when the UnRBUF register is read. 0 – Receive buffer is empty. 1 – Receive buffer is loaded. The Delta Clear To Send bit indicates whether the CTS input has changed state since the CPU last read this register. This functionality is only available for the UART0 module. 0 – No change since last read. 1 – State has changed since last read. www.national.com 144 3 0 UOVSR The Oversampling Rate field specifies the oversampling rate, as given in the following table. UOVSR3:0 Oversampling Rate 0000–0110 16 0111 7 1000 8 1001 9 1010 10 1011 11 1100 12 1101 13 1110 14 1111 15 The UnMDSL2 register is a byte-wide, read/write register that controls the sample mode used to recover asynchronous data. At reset, the UnOVR register is cleared. The register format is shown below. 7 1 USMD USMD BAUD RATE CALCULATIONS The USMD bit controls the sample mode for 20.4.1 Asynchronous Mode asynchronous transmission. 0 – UART determines the sample position au- The equation to calculate the baud rate in asynchronous mode is: tomatically. 1 – The UnSPOS register determines the SYS_CLKBR = ----------------------------sample position. (O × N × P) 20.3.11 UART Sample Position Register (UnSPOS) The UnSPOS register is a byte-wide, read/write register that specifies the sample position when the USMD bit in the UnMDSL2 register is set. At reset, the UnSPOS register is initialized to 06h. The register format is shown below. 7 4 3 Reserved USAMP 20.4 The UART baud rate is determined by the System Clock frequency and the values in the UnOVR, UnPSR, and UnBAUD registers. Unless the System Clock is an exact multiple of the baud rate, there will be a small amount of error in the resulting baud rate. 0 Reserved The USAMP field may be used to override the automatic selection, to choose any other clock period at which to start taking the three samples. where BR is the baud rate, SYS_CLK is the System Clock, O is the oversample rate, N is the baud rate divisor + 1, and P is the prescaler divisor selected by the UPSR register. Assuming a System Clock of 5 MHz, a desired baud rate of 9600, and an oversample rate of 16, the N × P term according to the equation above is: 0 6 ( 5 ×10 ) - = 32.552 N × P = -----------------------------( 16 × 9600 ) USAMP The Sample Position field specifies the oversample clock period at which to take the first of three samples for sensing the value of data bits. The clocks are numbered starting at 0 and may range up to 15 for 16× oversampling. The maximum value for this field is (oversampling rate - 3). The table below shows the clock period at which each of the three samples is taken, when automatic sampling is enabled (UnMDSL2.USMD = 0). The N × P term is then divided by each Prescaler Factor from Table 59 to obtain a value closest to an integer. The factor for this example is 6.5. N = 32.552 ------------------ = 5.008 (N = 5) 6.5 The baud rate register is programmed with a baud rate divisor of 4 (N = baud rate divisor + 1). This produces a baud clock of: 6 ( 5 ×10 ) BR = ----------------------------------= 9615.385 ( 16 × 5 × 6.5 ) 9615.385 – 9600 )- = 0.16 %error = (-----------------------------------------------9600 Sample Position Oversampling Rate 1 2 3 7 2 3 4 8 2 3 4 9 3 4 5 10 3 4 5 11 4 5 6 12 4 5 6 13 5 6 7 14 5 6 7 15 6 7 8 16 6 7 8 Note that the percent error is much lower than would be possible without the non-integer prescaler factor. Error greater than 3% is marginal and may result in unreliable operation. Refer to Table 61 below for more examples. 145 www.national.com CP3CN23 20.3.10 UART Mode Select Register 2 (UnMDSL2) CP3CN23 20.4.2 Synchronous Mode where BR is the baud rate, SYS_CLK is the System Clock, N is the value of the baud rate divisor + 1, and P is the prescaler divide factor selected by the value in the UnPSR register. Oversampling is not used in synchronous mode. Synchronous mode is only available for the UART0 module. When synchronous mode is selected and the UCKS bit is set, the UART operates from a clock received on the CKX pin. When the UCKS bit is clear, the UART uses the clock Use the same procedure to determine the values of N and from the internal baud rate generator which is also driven on P as in the asynchronous mode. In this case, however, only the CKX pin. When the internal baud rate generator is used, integer prescaler values are allowed. the equation for calculating the baud rate is: SYS_CLKBR = ---------------------------(2 × N × P) Table 61 Baud Rate Programming Baud Rate SYS_CLK = 48 MHz SYS_CLK = 24 MHz SYS_CLK = 12 MHz SYS_CLK = 10 MHz O N P %err O N P %err O N P %err O N P %err 300 16 2000 5.0 0.00 16 2000 2.5 0.00 16 1250 2.0 0.00 13 1282 2.0 0.00 600 16 2000 2.5 0.00 16 1250 2.0 0.00 16 1250 1.0 0.00 13 1282 1.0 0.00 1200 16 1250 2.0 0.00 16 1250 1.0 0.00 16 625 1.0 0.00 13 641 1.0 0.00 1800 7 401 9.5 0.00 8 1111 1.5 0.01 12 101 5.5 0.01 12 463 1.0 0.01 2000 16 1500 1.0 0.00 16 750 1.0 0.00 16 250 1.5 0.00 16 125 2.5 0.00 2400 16 1250 1.0 0.00 16 625 1.0 0.00 16 125 2.5 0.00 9 463 1.0 0.01 3600 8 1111 1.5 0.01 12 101 5.5 0.01 11 202 1.5 0.01 11 101 2.5 0.01 4800 16 625 1.0 0.00 16 125 2.5 0.00 10 250 1.0 0.00 7 119 2.5 0.04 7200 12 101 5.5 0.01 11 303 1.0 0.01 11 101 1.5 0.01 10 139 1.0 0.08 9600 16 125 2.5 0.00 10 250 1.0 0.00 10 125 1.0 0.00 7 149 1.0 0.13 14400 11 202 1.5 0.01 11 101 1.5 0.01 14 17 3.5 0.04 14 33 1.5 0.21 19200 10 250 1.0 0.00 10 125 1.0 0.00 10 25 2.5 0.00 16 13 2.5 0.16 38400 10 125 1.0 0.00 10 25 2.5 0.00 16 13 1.5 0.16 8 13 2.5 0.16 56000 7 49 2.5 0.04 13 33 1.0 0.10 13 11 1.5 0.10 7 17 1.5 0.04 115200 7 17 3.5 0.04 13 16 1.0 0.16 13 8 1.0 0.16 7 5 2.5 0.79 128000 15 25 1.0 0.00 15 5 2.5 0.00 11 1 8.5 0.27 12 1 6.5 0.16 230400 13 16 1.0 0.16 13 8 1.0 0.16 13 4 1.0 0.16 11 4 1.0 1.36 345600 9 1 15.5 0.44 10 7 1.0 0.79 10 1 3.5 0.79 460800 13 8 1.0 0.16 13 4 1.0 0.16 13 2 1.0 0.16 11 2 1.0 1.36 576000 8 7 1.5 0.79 12 1 3.5 0.79 14 1 1.5 0.79 7 1 2.5 0.79 691200 10 7 1.0 0.79 10 1 3.5 0.79 7 1 2.5 0.79 806400 7 1 8.5 0.04 15 2 1.0 0.79 10 1 1.5 0.79 921600 13 4 1.0 0.16 13 2 1.0 0.16 13 1 1.0 0.16 1105920 11 4 1.0 1.36 11 2 1.0 1.36 9 1 1.0 0.47 1382400 10 1 3.5 0.79 7 1 2.5 0.79 1536000 9 1 3.5 0.79 8 2 1.0 2.34 www.national.com 146 SYS_CLK = 8 MHz SYS_CLK = 6 MHz SYS_CLK = 5 MHz SYS_CLK = 4 MHz Baud Rate O N P %err O N P %err O N P %err O N P %err 300 7 401 9.5 0.00 16 1250 1.0 0.00 11 202 7.5 0.01 12 202 5.5 0.01 600 12 1111 1.0 0.01 16 625 1.0 0.00 11 101 7.5 0.01 12 101 5.5 0.01 1200 12 101 5.5 0.01 16 125 2.5 0.00 10 119 3.5 0.04 11 202 1.5 0.01 1800 8 101 5.5 0.01 11 303 1.0 0.01 11 101 2.5 0.01 11 202 1.0 0.01 2000 16 250 1.0 0.00 16 125 1.5 0.00 10 250 1.0 0.00 16 125 1.0 0.00 2400 11 303 1.0 0.01 10 250 1.0 0.00 7 119 2.5 0.04 11 101 1.5 0.01 3600 11 202 1.0 0.01 11 101 1.5 0.01 10 139 1.0 0.08 11 101 1.0 0.01 4800 11 101 1.5 0.01 10 125 1.0 0.00 7 149 1.0 0.13 14 17 3.5 0.04 7200 11 101 1.0 0.01 14 17 3.5 0.04 14 33 1.5 0.21 15 37 1.0 0.10 9600 14 17 3.5 0.04 10 25 2.5 0.00 16 13 2.5 0.16 7 17 3.5 0.04 14400 15 37 1.0 0.10 7 17 3.5 0.04 7 33 1.5 0.21 9 31 1.0 0.44 19200 7 17 3.5 0.04 16 13 1.5 0.16 8 13 2.5 0.16 16 13 1.0 0.16 38400 16 13 1.0 0.16 8 13 1.5 0.16 13 10 1.0 0.16 16 1 6.5 0.16 56000 13 11 1.0 0.10 9 12 1.0 0.79 15 6 1.0 0.79 13 1 5.5 0.10 115200 10 7 1.0 0.79 13 4 1.0 0.16 11 4 1.0 1.36 10 1 3.5 0.79 128000 9 7 1.0 0.79 16 3 1.0 2.34 13 3 1.0 0.16 9 1 3.5 0.79 230400 10 1 3.5 0.79 13 2 1.0 0.16 11 2 1.0 1.36 7 1 2.5 0.79 345600 15 1 1.5 2.88 7 1 2.5 0.79 460800 7 1 2.5 0.79 13 1 1.0 0.16 576000 7 2 1.0 0.79 7 1 1.5 0.79 SYS_CLK = 3 MHz SYS_CLK = 2 MHz SYS_CLK = 1 MHz SYS_CLK = 500 kHz Baud Rate O N P %err O N P %err O N P %err O N P %err 300 16 250 2.5 0.00 12 101 5.5 0.01 11 202 1.5 0.01 11 101 1.5 0.01 600 16 125 2.5 0.00 11 202 1.5 0.01 11 101 1.5 0.01 14 17 3.5 0.04 1200 10 250 1.0 0.00 11 101 1.5 0.01 14 17 3.5 0.04 7 17 3.5 0.04 1800 11 101 1.5 0.01 11 101 1.0 0.01 15 37 1.0 0.10 9 31 1.0 0.44 2000 15 100 1.0 0.00 16 25 2.5 0.00 10 50 1.0 0.00 10 25 1.0 0.00 2400 10 125 1.0 0.00 14 17 3.5 0.04 7 17 3.5 0.04 16 13 1.0 0.16 3600 14 17 3.5 0.04 15 37 1.0 0.10 9 31 1.0 0.44 9 1 15.5 0.44 4800 10 25 2.5 0.00 7 17 3.5 0.04 16 13 1.0 0.16 16 1 6.5 0.16 7200 7 17 3.5 0.04 9 31 1.0 0.44 9 1 15.5 0.44 10 7 1.0 0.79 9600 16 13 1.5 0.16 16 13 1.0 0.16 16 1 6.5 0.16 8 1 6.5 0.16 14400 13 16 1.0 0.16 9 1 15.5 0.44 10 7 1.0 0.79 10 1 3.5 0.79 19200 8 13 1.5 0.16 16 1 6.5 0.16 8 1 6.5 0.16 13 2 1.0 0.16 38400 13 6 1.0 0.16 8 1 6.5 0.16 13 2 1.0 0.16 13 1 1.0 0.16 56000 9 6 1.0 0.79 9 4 1.0 0.79 9 2 1.0 0.79 115200 13 2 1.0 0.16 7 1 2.5 0.79 128000 16 1 1.5 2.34 8 2 1.0 2.34 230400 13 1 1.0 0.16 147 www.national.com CP3CN23 Table 62 Baud Rate Programming CP3CN23 21.0 Microwire/SPI Interface Microwire/Plus is a synchronous serial communications protocol, originally implemented in National Semiconductor's COP8® and HPC families of microcontrollers to minimize the number of connections, and therefore the cost, of communicating with peripherals. The CP3CN23 has an enhanced Microwire/SPI interface module (MWSPI) that can communicate with all peripherals that conform to Microwire or Serial Peripheral Interface (SPI) specifications. This enhanced Microwire interface is capable of operating as either a master or slave and in 8- or 16-bit mode. Figure 65 shows a typical enhanced Microwire interface application. The enhanced Microwire interface module includes the following features: Programmable operation as a Master or Slave Programmable shift-clock frequency (master only) Programmable 8- or 16-bit mode of operation 8- or 16-bit serial I/O data shift register Two modes of clocking data Serial clock can be low or high when idle 16-bit read buffer Busy bit, Read Buffer Full bit, and Overrun bit for polling and as interrupt sources Supports multiple masters Maximum bit rate of 12M bits/second (master mode) 6M bits/second (slave mode) at 24 MHz System Clock Supports very low-end slaves with the Slave Ready output Echo back enable/disable (Slave only) MWCS GPIO CS I/O Lines 8-Bit A/D Master DO SK DI CS CS CS 1K Bit EEPROM LCD Display Driver VF Display Driver DO SK DI SK DI MDIDO MDODI MDODI MSK Figure 65. I/O Lines DI MDIDO MSK 21.1 SK Slave DS067 Microwire Interface MICROWIRE OPERATION 21.1.1 The Microwire interface allows several devices to be connected on one three-wire system. At any given time, one of these devices operates as the master while all other devices operate as slaves. The Microwire interface allows the device to operate either as a master or slave transferring 8- or 16bits of data. Shifting The Microwire interface is a full duplex transmitter/receiver. A 16-bit shifter, which can be split into a low and high byte, is used for both transmitting and receiving. In 8-bit mode, only the lower 8-bits are used to transfer data. The transmitted data is shifted out through MDODI pin (master mode) or MDIDO pin (slave mode), starting with the most significant bit. At the same time, the received data is shifted in through MDIDO pin (master mode) or MDODI pin (slave mode), also starting with the most significant bit first. The master device supplies the synchronous clock (MSK) for the serial interface and initiates the data transfer. The slave devices respond by sending (or receiving) the requested data. Each slave device uses the master’s clock for The shift in and shift out are controlled by the MSK clock. In serially shifting data out (or in), while the master shifts the each clock cycle of MSK, one bit of data is transmitted/received. The 16-bit shifter is accessible as the MWDAT regdata in (or out). ister. Reading the MWDAT register returns the value in the The three-wire system includes: the serial data in signal read buffer. Writing to the MWDAT register updates the 16(MDIDO for master mode, MDODI for slave mode), the sebit shifter. rial data out signal (MDODI for master mode, MDIDO for slave mode), and the serial clock (MSK). In slave mode, an optional fourth signal (MWCS) may be used to enable the slave transmit. At any given time, only one slave can respond to the master. Each slave device has its own chip select signal (MWCS) for this purpose. Figure 66 shows a block diagram of the enhanced Microwire serial interface in the device. www.national.com 148 Write Data Control + Status CP3CN23 Interrupt Request MWCS 16-BIt Read Buffer Write Data 8 8 MWDAT 16-BIt Shift Register Data Out Slave Master MDODI Slave Data In Master MDIDO MSK System Clock Clock Prescaler + Select Master Figure 66. 21.1.2 MSK DS068 Microwire Block Diagram Reading 21.1.4 The enhanced Microwire interface implements a double buffer on read. As illustrated in Figure 66, the double read buffer consists of the 16-bit shifter and a buffer, called the read buffer. Clocking Modes Two clocking modes are supported: the normal mode and the alternate mode. In the normal mode, the output data, which is transmitted on the MDODI pin (master mode) or the MDIDO pin (slave The 16-bit shifter loads the read buffer with new data when mode), is clocked out on the falling edge of the shift clock the data transfer sequence is completed and previous data MSK. The input data, which is received via the MDIDO pin in the read buffer has been read. In master mode, an Over- (master mode) or the MDODI pin (slave mode), is sampled run error occurs when the read buffer is full, the 16-bit shifter on the rising edge of MSK. is full and a new data transfer sequence starts. In the alternate mode, the output data is shifted out on the When 8-bit mode is selected, the lower byte of the shift reg- rising edge of MSK on the MDODI pin (master mode) or ister is loaded into the lower byte of the read buffer and the MDIDO pin (slave mode). The input data, which is received read buffer’s higher byte remains unchanged. via MDIDO pin (master mode) or MDODI pin (slave mode), The RBF bit indicates if the MWDAT register holds valid da- is sampled on the falling edge of MSK. ta. The OVR bit indicates that an overrun condition has occurred. The clocking modes are selected with the SCM bit. The SCIDL bit allows selection of the value of MSK when it is idle (when there is no data being transferred). Various MSK 21.1.3 Writing clock frequencies can be programmed via the MCDV bits. The BSY bit indicates whether the MWDAT register can be Figures Figure 67, Figure 68, Figure 69, and Figure 70 show written. All write operations to the MWDAT register update the the data transfer timing for the normal and the alternate shifter while the data contained in the read buffer is not affect- modes with the SCIDL bit clear and set. ed. Undefined results will occur if the MWDAT register is writNote that when data is shifted out on MDODI (master mode) ten to while the BSY bit is set. or MDIDO (slave mode) on the leading edge of the MSK clock, bit 14 (16-bit mode) is shifted out on the second leading edge of the MSK clock. When data are shifted out on MDODI (master mode) or MDIDO (slave mode) on the trailing edge of MSK, bit 14 (16-bit mode) is shifted out on the first trailing edge of MSK. 149 www.national.com CP3CN23 21.2 MASTER MODE In Master mode, the MSK pin is an output for the shift clock, MSK. When data is written to the MWDAT register, eight or sixteen MSK clocks, depending on the mode selected, are generated to shift the 8 or 16 bits of data, and then MSK goes idle again. The MSK idle state can be either high or low, depending on the SCIDL bit. End of Transfer MSK Shift Out Data Out MSB MSB - 1 MSB - 2 Bit 1 Bit 0 (LSB) MSB - 1 MSB - 2 Bit 1 Bit 0 (LSB) Sample Point Data In MSB DS069 Figure 67. Normal Mode (SCIDL = 0) End of Transfer MSK Shift Out MSB Data Out MSB - 1 MSB - 2 Bit 1 Bit 0 (LSB) MSB - 1 MSB - 2 Bit 1 Bit 0 (LSB) Sample Point MSB Data In DS070 Figure 68. Normal Mode (SCIDL = 1) End of Transfer MSK Shift Out MSB Data Out MSB - 1 MSB - 2 Bit 1 Bit 0 (LSB) MSB - 1 MSB - 2 Bit 1 Bit 0 (LSB) Sample Point MSB Data In DS071 Figure 69. Alternate Mode (SCIDL = 0) End of Transfer MSK Shift Out Data Out MSB MSB - 1 MSB - 2 Bit 1 Bit 0 (LSB) MSB - 1 MSB - 2 Bit 1 Bit 0 (LSB) Sample Point Data In MSB DS072 Figure 70. Alternate Mode (SCIDL = 1) www.national.com 150 SLAVE MODE 21.4 In Slave mode, the MSK pin is an input for the shift clock MSK. MDIDO is placed in TRI-STATE mode when MWCS is inactive. Data transfer is enabled when MWCS is active. INTERRUPT GENERATION Interrupts may be enabled for any of the conditions shown in Table 63. Table 63 Microwire Interrupt Trigger Condition The slave starts driving MDIDO when MWCS is active. The most significant bit (lower byte in 8-bit mode or upper byte in 16-bit mode) is output onto the MDIDO pin first. After eight or sixteen clocks (depending on the selected mode), the data transfer is completed. Interrupt Status Enable Bit Bit in the Condition in the MWSTAT MWCTRL1 Register Register If a new shift process starts before MWDAT was written, i.e., while MWDAT does not contain any valid data, and the ECHO bit is set, the data received from MDODI is transmitted on MDIDO in addition to being shifted to MWDAT. If the ECHO bit is clear, the data transmitted on MDIDO is the data held in the MWDAT register, regardless of its validity. The master may negate the MWCS signal to synchronize the bit count between the master and the slave. In the case that the slave is the only slave in the system, MWCS can be tied to ground. Description Not Busy BSY EIW The shifter is ready for the next data transfer sequence. Read Buffer Full RBF EIR The read buffer is full and waiting to be unloaded. EIO A new data transfer sequence started while both the shifter and the read buffer were full. Overrun OVF Figure 71 illustrates the interrupt generation logic of this module. EIO OVR = 1 EIR MWSPI Interrupt RBF = 1 EIW BSY = 0 DS073 Figure 71. 151 MWSPI Interrupts www.national.com CP3CN23 21.3 CP3CN23 21.5 MICROWIRE INTERFACE REGISTERS 21.5.2 MICROWIRE Control Register (MWCTL1) Software interacts with the Microwire interface by accessing The MWCTL1 register is a word-wide, read/write register used to control the Microwire module. To avoid clock glitchthe Microwire registers. There are three such registers: es, the MWEN bit must be clear while changing the states Table 64 Microwire Interface Registers of any other bits in the register. At reset, all non-reserved bits are cleared. The register format is shown below. Name Address Description MWDAT Microwire Data Register FF F3A0h MWCTL1 FF F3A2h Microwire Control Register MWSTAT FF F3A4h Microwire Status Register 21.5.1 7 6 5 4 SCM EIW EIR EIO MWEN 0 MWDAT MSK Write DIN 1 Read Buffer (Low Byte) Read Buffer (High Byte) MOD MNS Read DS074 Figure 72. MWDAT Register MOD ECHO www.national.com 152 SCIDL State When Disabled Master – SCIDL Bit Slave – Input MWCS Input MDIDO Master – Input Slave – TRI-STATE MDODI Master – Known value Slave – Input DOUT 0 8 The Microwire Enable bit controls whether the Microwire interface module is enabled. 0 – Microwire module disabled. 1 – Microwire module enabled. Clearing this bit disables the module, clears the status bits in the Microwire status register (the BSY, RBF, and OVR bits in MWSTAT), and places the Microwire interface pins in the states described below. Pin MWDAT 0 9 Figure 72 shows the hardware structure of the register. Shifter (High Byte) 1 MNS MWEN SCDV The MWDAT register is a word-wide, read/write register used to transmit and receive data through the MDODI and MDIDO pins. The register format is shown below. Shifter (Low Byte) 2 15 Microwire Data Register (MWDAT) 7 3 ECHO MOD The Master/Slave Select bit controls whether the CP3CN23 is a master or slave. When clear, the device operates as a slave. When set, the device operates as the master. 0 – CP3CN23 is slave. 1 – CP3CN23 is master. The Mode Select bit controls whether 8- or 16bit mode is used. When clear, the device operates in 8-bit mode. When set, the device operates in 16-bit mode. This bit must only be changed when the module is disabled or idle (MWSTAT.BSY = 0). 0 – 8-bit mode. 1 – 16-bit mode. The Echo Back bit controls whether the echo back function is enabled in slave mode. This bit must be written only when the Microwire interface is idle (MWSTAT.BSY=0). The ECHO bit is ignored in master mode. The MWDAT register is valid from the time the register has been written until the end of the transfer. In the echo back mode, MDODI is transmitted (echoed back) on MDIDO if the MWDAT register does not contain any valid data. With the echo back function disabled, the data held in the EIR EIW SCM SCIDL SCDV 21.5.3 Microwire Status Register (MWSTAT) The MWSTAT register is a word-wide, read-only register that shows the current status of the Microwire interface module. At reset, all non-reserved bits are clear. The register format is shown below. 15 3 Reserved BSY RBF OVR 153 2 1 0 OVR RBF BSY The Busy bit, when set, indicates that the Microwire shifter is busy. In master mode, the BSY bit is set when the MWDAT register is written. In slave mode, the bit is set on the first leading edge of MSK when MWCS is asserted or when the MWDAT register is written, whichever occurs first. In both master and slave modes, this bit is cleared when the Microwire data transfer sequence is completed and the read buffer is ready to receive the new data; in other words, when the previous data held in the read buffer has already been read. If the previous data in the read buffer has not been read and new data has been received into the shift register, the BSY bit will not be cleared, as the transfer could not be completed because the contents of the shift register could not be transferred into the read buffer. 0 – Microwire shifter is not busy. 1 – Microwire shifter is busy. The Read Buffer Full bit, when set, indicates that the Microwire read buffer is full and ready to be read by software. It is set when the shifter loads the read buffer, which occurs upon completion of a transfer sequence if the read buffer is empty. The RBF bit is updated when the MWDAT register is read. At that time, the RBF bit is cleared if the shifter does not contain any new data (in other words, the shifter is not receiving data or has not yet received a full byte of data). The RBF bit remains set if the shifter already holds new data at the time that MWDAT is read. In that case, MWDAT is immediately reloaded with the new data and is ready to be read by software. 0 – Microwire read buffer is not full. 1 – Microwire read buffer is full. The Receive Overrun Error bit, when set in master mode, indicates that a receive overrun error has occurred. This error occurs when the read buffer is full, the 8-bit shifter is full, and a new data transfer sequence starts. This bit is undefined in slave mode. The OVR bit, once set, remains set until cleared by software. Software clears this bit by writing a 1 to its bit position. Writing a 0 to this bit position has no effect. No other bits in the MWSTAT register are affected by a write operation to the register. 0 – No receive overrun error has occurred. 1 – Receive overrun error has occurred. www.national.com CP3CN23 EIO MWDAT register is transmitted on MDIDO, whether or not the data is valid. 0 – Echo back disabled. 1 – Echo back enabled. The Enable Interrupt on Overrun bit enables or disables the overrun error interrupt. When set, an interrupt is generated when the Receive Overrun Error bit (MWSTAT.OVR) is set. Otherwise, no interrupt is generated when an overrun error occurs. This bit must only be enabled in master mode. 0 – Disable overrun error interrupts. 1 – Enable overrun error interrupts. The Enable Interrupt for Read bit controls whether an interrupt is generated when the read buffer becomes full. When set, an interrupt is generated when the Read Buffer Full bit (MWSTAT.RBF) is set. Otherwise, no interrupt is generated when the read buffer is full. 0 – No read buffer full interrupt. 1 – Interrupt when read buffer becomes full. The Enable Interrupt for Write bit controls whether an interrupt is generated when the Busy bit (MWSTAT.BSY) is cleared, which indicates that a data transfer sequence has been completed and the read buffer is ready to receive the new data. Otherwise, no interrupt is generated when the Busy bit is cleared. 0 – No interrupt on data transfer complete. 1 – Interrupt on data transfer complete. The Shift Clock Mode bit selects between the normal clocking mode and the alternate clocking mode. In the normal mode, the output data is clocked out on the falling edge of MSK and the input data is sampled on the rising edge of MSK. In the alternate mode, the output data is clocked out on the rising edge of MSK and the input data is sampled on the falling edge of MSK. 0 – Normal clocking mode. 1 – Alternate clocking mode. The Shift Clock Idle bit controls the value of the MSK output when the Microwire module is idle. This bit must be changed only when the Microwire module is disabled (MEN = 0) or when no bus transaction is in progress (MWSTAT.BSY = 0). 0 – MSK is low when idle. 1 – MSK is high when idle The Shift Clock Divider Value field specifies the divisor used for generating the MSK shift clock from the System Clock. The divisor is 2 × (SCDV[6:0] + 1). Valid values are 0000001b to 1111111b, so the division ratio may range from 3 to 256. This field is ignored in slave mode (MWCTL1.MNS=0). CP3CN23 22.0 ACCESS.bus Interface The ACCESS.bus interface module (ACB) is a two-wire serial interface compatible with the ACCESS.bus physical layer. It permits easy interfacing to a wide range of low-cost memories and I/O devices, including: EEPROMs, SRAMs, timers, A/D converters, D/A converters, clock chips, and peripheral drivers. It is compatible with Intel’s SMBus and Philips’ I2C bus. The ACB module can be configured as a bus master or slave, and can maintain bidirectional communications with both multiple master and slave devices. SDA SCL Data Line Stable: Data Valid This section presents an overview of the bus protocol, and its implementation by the ACB module. ACCESS.bus master and slave Supports polling and interrupt-controlled operation Generate a wake-up signal on detection of a Start Condition, while in power-down mode Optional internal pull-up on SDA and SCL pins 22.1 ACB PROTOCOL OVERVIEW Change of Data Allowed DS075 Figure 73. Bit Transfer Each data transaction is composed of a Start Condition, a number of byte transfers (programmed by software), and a Stop Condition to terminate the transaction. Each byte is transferred with the most significant bit first, and after each byte, an Acknowledge signal must follow. At each clock cycle, the slave can stall the master while it handles the previous data, or prepares new data. This can be performed for each bit transferred or on a byte boundary by the slave holding SCL low to extend the clock-low period. Typically, slaves extend the first clock cycle of a transfer if a byte read has not yet been stored, or if the next byte to be transmitted is not yet ready. Some microcontrollers with limThe ACCESS.bus protocol supports multiple master and ited hardware support for ACCESS.bus extend the access slave transmitters and receivers. Each bus device has a after each bit, to allow software time to handle this bit. unique address and can operate as a transmitter or a re- Start and Stop ceiver (though some peripherals are only receivers). The ACCESS.bus master generates Start and Stop CondiDuring data transactions, the master device initiates the tions (control codes). After a Start Condition is generated, transaction, generates the clock signal, and terminates the the bus is considered busy and it retains this status until a transaction. For example, when the ACB initiates a data certain time after a Stop Condition is generated. A high-totransaction with an ACCESS.bus peripheral, the ACB be- low transition of the data line (SDA) while the clock (SCL) is comes the master. When the peripheral responds and high indicates a Start Condition. A low-to-high transition of transmits data to the ACB, their master/slave (data transac- the SDA line while the SCL is high indicates a Stop Condition initiator and clock generator) relationship is unchanged, tion (Figure 74). even though their transmitter/receiver functions are reversed. The ACCESS.bus protocol uses a two-wire interface for bidirectional communication between the devices connected to the bus. The two interface signals are the Serial Data Line (SDA) and the Serial Clock Line (SCL). These signals should be connected to the positive supply, through pull-up resistors, to keep the signals high when the bus is idle. 22.1.1 SDA Data Transactions One data bit is transferred during each clock period. Data is sampled during the high phase of the serial clock (SCL). Consequently, throughout the clock high phase, the data must remain stable (see Figure 73). Any change on the SDA signal during the high phase of the SCL clock and in the middle of a transaction aborts the current transaction. New data must be driven during the low phase of the SCL clock. This protocol permits a single data line to transfer both command/control information and data using the synchronous serial clock. www.national.com SCL P S Start Condition Stop Condition DS076 Figure 74. Start and Stop Conditions In addition to the first Start Condition, a repeated Start Condition can be generated in the middle of a transaction. This allows another device to be accessed, or a change in the direction of the data transfer. 154 Addressing Transfer Formats The Acknowledge Cycle consists of two signals: the acknowledge clock pulse the master sends with each byte transferred, and the acknowledge signal sent by the receiving device (Figure 75). Each device on the bus has a unique address. Before any data is transmitted, the master transmits the address of the slave being addressed. The slave device should send an acknowledge signal on the SDA signal, once it recognizes its address. Acknowledgment Signal from Receiver The address is the first seven bits after a Start Condition. The direction of the data transfer (R/W) depends on the bit sent after the address (the eighth bit). A low-to-high transition during a SCL high period indicates the Stop Condition, and ends the transaction (Figure 77). SDA MSB SCL 1 2 3-6 7 8 S Start Condition 9 ACK 1 2 3-8 9 ACK P Stop Condition Clock Line Held Low by Receiver While Interrupt is Serviced Byte Complete Interrupt Within Receiver SDA DS077 SCL Figure 75. 1-7 The master generates the acknowledge clock pulse on the ninth clock pulse of the byte transfer. The transmitter releases the SDA line (permits it to go high) to allow the receiver to send the acknowledge signal. The receiver must pull down the SDA line during the acknowledge clock pulse, which signals the correct reception of the last data byte, and its readiness to receive the next byte. Figure 76 illustrates the acknowledge cycle. Data Output by Transmitter Transmitter Stays Off the Bus During the Acknowledgment Clock Acknowledgment Signal from Receiver 1 2 3-6 7 8 1-7 8 9 1-7 8 9 R/W ACK Start Condition Data ACK Data ACK Stop Condition DS079 Figure 77. A Complete ACCESS.bus Data Transaction When the address is sent, each device in the system compares this address with its own. If there is a match, the device considers itself addressed and sends an acknowledge signal. Depending upon the state of the R/W bit (1 = read, 0 = write), the device acts as a transmitter or a receiver. The ACCESS.bus protocol allows sending a general call address to all slaves connected to the bus. The first byte sent specifies the general call address (00h) and the second byte specifies the meaning of the general call (for example, “Write slave address by software only”). Those slaves that require the data acknowledge the call and become slave receivers; the other slaves ignore the call. Data Output by Receiver S Start Condition 9 P Address SCL 8 S ACCESS.bus Data Transaction 9 DS078 Arbitration on the Bus Figure 76. ACCESS.bus Acknowledge Cycle The master generates an acknowledge clock pulse after each byte transfer. The receiver sends an acknowledge signal after every byte received. There are two exceptions to the “acknowledge after every byte” rule. When the master is the receiver, it must indicate to the transmitter an end-of-data condition by not-acknowledging (“negative acknowledge”) the last byte clocked out of the slave. This “negative acknowledge” still includes the acknowledge clock pulse (generated by the master), but the SDA line is not pulled down. When the receiver is full, otherwise occupied, or a problem has occurred, it sends a negative acknowledge to indicate that it cannot accept additional data bytes. Arbitration is required when multiple master devices attempt to gain control of the bus simultaneously. Control of the bus is initially determined according to address bits and clock cycle. If the masters are trying to address the same bus device, data comparisons determine the outcome of this arbitration. In master mode, the device immediately aborts a transaction if the value sampled on the SDA lines differs from the value driven by the device. (Exceptions to this rule are SDA while receiving data; in these cases the lines may be driven low by the slave without causing an abort.) The SCL signal is monitored for clock synchronization and allows the slave to stall the bus. The actual clock period will be the one set by the master with the longest clock period or by the slave stall period. The clock high period is determined by the master with the shortest clock high period. When an abort occurs during the address transmission, the master that identifies the conflict should give up the bus, switch to slave mode, and continue to sample SDA to see if it is being addressed by the winning master on the ACCESS.bus. 155 www.national.com CP3CN23 Acknowledge Cycle CP3CN23 22.2 ACB FUNCTIONAL DESCRIPTION 4. If the requested direction is transmit, and the start transaction was completed successfully (i.e., neither the ACBST.NEGACK nor ACBST.BER bit is set, and no other master has accessed the device), the ACBST.SDAST bit is set to indicate that the module is waiting for service. 5. If the requested direction is receive, the start transaction was completed successfully, and the ACBCTL1.STASTRE bit is clear, the module starts receiving the first byte automatically. 6. Check that both the ACBST.BER and ACBST.NEGACK bits are clear. If the ACBCTL1.INTEN bit is set, an interrupt is generated when either the ACBST.BER or ACBST.NEGACK bit is set. The ACB module provides the physical layer for an ACCESS.bus compliant serial interface. The module is configurable as either a master or slave device. As a slave, the ACB module may issue a request to become the bus master. 22.2.1 Master Mode An ACCESS.bus transaction starts with a master device requesting bus mastership. It sends a Start Condition, followed by the address of the device it wants to access. If this transaction is successfully completed, software can assume that the device has become the bus master. For a device to become the bus master, software should perform the following steps: 1. Set the ACBCTL1.START bit, and configure the ACBCTL1.INTEN bit to the desired operation mode (Polling or Interrupt). This causes the ACB to issue a Start Condition on the ACCESS.bus, as soon as the ACCESS.bus is free (ACBCST.BB=0). It then stalls the bus by holding SCL low. 2. If a bus conflict is detected, (i.e., some other device pulls down the SCL signal before this device does), the ACBST.BER bit is set. 3. If there is no bus conflict, the ACBST.MASTER and ACBST.SDAST bits are set. 4. If the ACBCTL1.INTEN bit is set, and either the ACBST.BER bit or the ACBST.SDAST bit is set, an interrupt is sent to the ICU. Sending the Address Byte Master Transmit After becoming the bus master, the device can start transmitting data on the ACCESS.bus. To transmit a byte, software must: 1. Check that the BER and NEGACK bits in the ACBST register are clear and the ACBST.SDAST bit is set. Also, if the ACBCTL1.STASTRE bit is set, check that the ACBST.STASTR bit is clear. 2. Write the data byte to be transmitted to the ACBSDA register. When the slave responds with a negative acknowledge, the ACBST.NEGACK bit is set and the ACBST.SDAST bit remains cleared. In this case, if the ACBCTL1.INTEN bit is set, an interrupt is sent to the core. Master Receive After becoming the bus master, the device can start receivOnce this device is the active master of the ACCESS.bus ing data on the ACCESS.bus. To receive a byte, software (ACBST.MASTER = 1), it can send the address on the bus. must: The address should not be this device’s own address as specified in the ACBADDR.ADDR field if the ACBAD- 1. Check that the ACBST.SDAST bit is set and the ACBST.BER bit is clear. Also, if the ACBCTL1.STASTRE bit DR.SAEN bit is set or the ACBADDR2.ADDR field if the is set, check that the ACBST.STASTR bit is clear. ACBADDR2.SAEN bit is set, nor should it be the global call 2. Set the ACBCTL1.ACK bit, if the next byte is the last address if the ACBST.GCMTCH bit is set. byte that should be read. This causes a negative acTo send the address byte use the following sequence: knowledge to be sent. 1. Configure the ACBCTL1.INTEN bit according to the de- 3. Read the data byte from the ACBSDA register. sired operation mode. For a receive transaction where software wants only one byte of data, it should set the Master Stop ACBCTL1.ACK bit. If only an address needs to be sent, A Stop Condition may be issued only when this device is the set the ACBCTL1.STASTRE bit. active bus master (ACBST.MASTRER = 1). To end a trans2. Write the address byte (7-bit target device address), action, set the ACBCTL1.STOP bit before clearing the curand the direction bit, to the ACBSDA register. This rent stall bit (i.e., the ACBST.SDAST, ACBST.NEGACK, or causes the module to generate a transaction. At the ACBST.STASTR bit). This causes the module to send a end of this transaction, the acknowledge bit received is Stop Condition immediately, and clear the ACBCTL1.STOP copied to the ACBST.NEGACK bit. During the transac- bit. tion, the SDA and SCL signals are continuously checked for conflict with other devices. If a conflict is detected, the transaction is aborted, the ACBST.BER bit is set, and the ACBST.MASTER bit is cleared. 3. If the ACBCTL1.STASTRE bit is set, and the transaction was successfully completed (i.e., both the ACBST.BER and ACBST.NEGACK bits are cleared), the ACBST.STASTR bit is set. In this case, the ACB stalls any further ACCESS.bus operations (i.e., holds SCL low). If the ACBCTL1.INTE bit is set, it also sends an interrupt to the core. www.national.com 156 22.2.2 The ACB module can stall the ACCESS.bus between transfers while waiting for the core’s response. The ACCESS.bus is stalled by holding the SCL signal low after the acknowledge cycle. Note that this is interpreted as the beginning of the following bus operation. Software must make sure that the next operation is prepared before the bit that causes the bus stall is cleared. A slave device waits in Idle mode for a master to initiate a bus transaction. Whenever the ACB is enabled, and it is not acting as a master (i.e., ACBST.MASTER = 0), it acts as a slave device. Slave Mode Once a Start Condition on the bus is detected, this device checks whether the address sent by the current master matches either: The bits that can cause a stall in master mode are: The ACBADDR.ADDR value if the ACBADDR.SAEN bit Negative acknowledge after sending a byte is set. (ACBSTNEGACK = 1). The ACBADDR2.ADDR value if the ACBADDR2.SAEN ACBST.SDAST bit is set. bit is set. If the ACBCTL1.STASTRE bit is set, after a successful The general call address if the ACBCTL1.GCM bit is set. start (ACBST.STASTR = 1). This match is checked even when the ACBST.MASTER bit is set. If a bus conflict (on SDA or SCL) is detected, the Repeated Start ACBST.BER bit is set, the ACBST.MASTER bit is cleared, A repeated start is performed when this device is already and this device continues to search the received message the bus master (ACBST.MASTER = 1). In this case, the ACfor a match. If an address match, or a global match, is deCESS.bus is stalled and the ACB waits for the core handling tected: due to: negative acknowledge (ACBST.NEGACK = 1), empty buffer (ACBST.SDAST = 1), or a stop-after-start (ACB- 1. This device asserts its data pin during the acknowledge cycle. ST.STASTR = 1). 2. The ACBCST.MATCH, ACBCST.MATCHAF (or For a repeated start: ACBCST.GCMTCH if it is a global call address match, 1. Set the ACBCTL1.START bit. or ACBCST.ARPMATCH if it is an ARP address), and 2. In master receive mode, read the last data item from ACBST.NMATCH in the ACBCST register are set. If the the ACBSDA register. ACBST.XMIT bit is set (i.e., slave transmit mode), the 3. Follow the address send sequence, as described in ACBST.SDAST bit is set to indicate that the buffer is “Sending the Address Byte” on page 156. empty. 4. If the ACB was waiting for handling due to ACB- 3. If the ACBCTL1.INTEN bit is set, an interrupt is generST.STASTR = 1, clear it only after writing the requested ated if both the INTEN and NMINTE bits in the address and direction to the ACBSDA register. ACBCTL1 register are set. 4. Software then reads the ACBST.XMIT bit to identify the Master Error Detections direction requested by the master device. It clears the The ACB detects illegal Start or Stop Conditions (i.e., a ACBST.NMATCH bit so future byte transfers are identiStart or Stop Condition within the data transfer, or the acfied as data bytes. knowledge cycle) and a conflict on the data lines of the ACCESS.bus. If an illegal action is detected, the BER bit is set, Slave Receive and Transmit and the MASTER mode is exited (the MASTER bit is Slave Receive and Transmit are performed after a match is cleared). detected and the data transfer direction is identified. After a byte transfer, the ACB extends the acknowledge clock until Bus Idle Error Recovery software reads or writes the ACBSDA register. The receive When a request to become the active bus master or a re- and transmit sequence are identical to those used in the start operation fails, the ACBST.BER bit is set to indicate the master routine. error. In some cases, both this device and the other device may identify the failure and leave the bus idle. In this case, Slave Bus Stall the start sequence may not be completed and the AC- When operating as a slave, this device stalls the ACCESS.bus may remain deadlocked. CESS.bus by extending the first clock cycle of a transaction in the following cases: To recover from deadlock, use the following sequence: 1. Clear the ACBST.BER and ACBCST.BB bits. 2. Wait for a time-out period to check that there is no other active master on the bus (i.e., the ACBCST.BB bit remains clear). 3. Disable, and re-enable the ACB to put it in the non-addressed slave mode. 4. At this point, some of the slaves may not identify the bus error. To recover, the ACB becomes the bus master by issuing a Start Condition and sends an address field; then issue a Stop Condition to synchronize all the slaves. — The ACBST.SDAST bit is set. — The ACBST.NMATCH, and ACBCTL1.NMINTE bits are set. Slave Error Detections The ACB detects illegal Start and Stop Conditions on the ACCESS.bus (i.e., a Start or Stop Condition within the data transfer or the acknowledge cycle). When an illegal Start or Stop Condition is detected, the BER bit is set and the MATCH and GMATCH bits are cleared, causing the module to be an unaddressed slave. 157 www.national.com CP3CN23 Master Bus Stall CP3CN23 Power Down 22.3.1 When this device is in Power Save, Idle, or Halt mode, the ACB module is not active but retains its status. If the ACB is enabled (ACBCTL2.ENABLE = 1) on detection of a Start Condition, a wake-up signal is issued to the MIWU module. Use this signal to switch this device to Active mode. The ACBSDA register is a byte-wide, read/write shift register used to transmit and receive data. The most significant bit is transmitted (received) first and the least significant bit is transmitted (received) last. Reading or writing to the ACBSDA register is allowed when ACBST.SDAST is set; or for repeated starts after setting the START bit. An attempt to access the register in other cases produces unpredictable results. The ACB module cannot check the address byte for a match following the start condition that caused the wake-up event for this device. The ACB responds with a negative acknowledge, and the device should resend both the Start Condition and the address after this device has had time to wake up. 7 Check that the ACBCST.BUSY bit is inactive before entering Power Save, Idle, or Halt mode. This guarantees that the device does not acknowledge an address sent and stop re22.3.2 sponding later. 22.2.3 SDA and SCL Pins Configuration The SDA and SCL pins are driven as open-drain signals. For more information, see the I/O configuration section. 22.2.4 ACB Serial Data Register (ACBSDA) 0 DATA ACB Status Register (ACBST) The ACBST register is a byte-wide, read-only register that maintains current ACB status. At reset, and when the module is disabled, ACBST is cleared. ACB Clock Frequency Configuration 7 6 5 4 3 2 1 0 The ACB module permits software to set the clock frequen- SLVSTP SDAST BER NEGACK STASTR NMATCH MASTER XMIT cy used for the ACCESS.bus clock. The clock is set by the ACBCTL2.SCLFRQ field. This field determines the SCL clock period used by this device. This clock low period may XMIT The Direction Bit bit is set when the ACB modbe extended by stall periods initiated by the ACB module or ule is currently in master/slave transmit mode. by another ACCESS.bus device. In case of a conflict with Otherwise it is cleared. another bus master, a shorter clock high period may be 0 – Receive mode. forced by the other bus master until the conflict is resolved. 1 – Transmit mode. MASTER The Master bit indicates that the module is 22.3 ACCESS.BUS INTERFACE REGISTERS currently in master mode. It is set when a reThe ACCESS.bus interface uses the registers listed in quest for bus mastership succeeds. It is Table 65. cleared upon arbitration loss (BER is set) or the recognition of a Stop Condition. Table 65 ACCESS.bus Interface Registers 0 – Slave mode. 1 – Master mode. Name Address Description NMATCH The New match bit is set when the address ACB Serial Data byte following a Start Condition, or repeated ACBSDA FF F2A0h Register starts, causes a match or a global-call match. The NMATCH bit is cleared when written with ACBST FF F2A2h ACB Status Register 1. Writing 0 to NMATCH is ignored. If the ACBCTL1.INTEN bit is set, an interrupt is sent ACB Control Status ACBCST FF F2A4h when this bit is set. Register 0 – No match. ACB Control 1 – Match or global-call match. ACBCTL1 FF F2A6h Register 1 STASTR The Stall After Start bit is set by the successful completion of an address sending (i.e., a Start ACB Control ACBCTL2 FF F2AAh Condition sent without a bus error, or negative Register 2 acknowledge), if the ACBCTL1.STASTRE bit is set. This bit is ignored in slave mode. When ACB Control ACBCTL3 FF F2AEh the STASTR bit is set, it stalls the bus by pullRegister 3 ing down the SCL line, and suspends any othACB Own Address er action on the bus (e.g., receives first byte in ACBADDR1 FF F2A8h Register 1 master receive mode). In addition, if the ACBCTL1.INTEN bit is set, it also sends an ACB Own Address ACBADDR2 FF F2ACh interrupt to the core. Writing 1 to the STASTR Register 2 bit clears it. It is also cleared when the module is disabled. Writing 0 to the STASTR bit has no effect. 0 – No stall after start condition. 1 – Stall after successful start. www.national.com 158 BER SDAST SLVSTP The Negative Acknowledge bit is set by hardware when a transmission is not acknowledged on the ninth clock. (In this case, the SDAST bit is not set.) Writing 1 to NEGACK clears it. It is also cleared when the module is disabled. Writing 0 to the NEGACK bit is ignored. 0 – No transmission not acknowledged condition. 1 – Transmission not acknowledged. The Bus Error bit is set by the hardware when a Start or Stop Condition is detected during data transfer (i.e., Start or Stop Condition during the transfer of bits 2 through 8 and acknowledge cycle), or when an arbitration problem is detected. Writing 1 to the BER bit clears it. It is also cleared when the module is disabled. Writing 0 to the BER bit is ignored. 0 – No bus error occurred. 1 – Bus error occurred. The SDA Status bit indicates that the SDA data register is waiting for data (transmit, as master or slave) or holds data that should be read (receive, as master or slave). This bit is cleared when reading from the ACBSDA register during a receive, or when written to during a transmit. When the ACBCTL1.START bit is set, reading the ACBSDA register does not clear the SDAST bit. This enables the ACB to send a repeated start in master receive mode. 0 – ACB module is not waiting for data transfer. 1 – ACB module is waiting for data to be loaded or unloaded. The Slave Stop bit indicates that a Stop Condition was detected after a slave transfer (i.e., after a slave transfer in which MATCH or GCMATCH is set). Writing 1 to SLVSTP clears it. It is also cleared when the module is disabled. Writing 0 to SLVSTP is ignored. 0 – No stop condition after slave transfer occurred. 1 – Stop condition after slave transfer occurred. 22.3.3 ACB Control Status Register (ACBCST) The ACBCST register is a byte-wide, read/write register that maintains current ACB status. At reset and when the module is disabled, the non-reserved bits of ACBCST are cleared. 7 6 5 4 3 2 1 0 Reserved TGSCL TSDA GCMTCH MATCH BB BUSY BUSY BB MATCH 159 The BUSY bit indicates that the ACB module is: Generating a Start Condition In Master mode (ACBST.MASTER is set) In Slave mode (ACBCST.MATCH or ACBCST.GCMTCH is set) In the period between detecting a Start and completing the reception of the address byte. After this, the ACB either becomes not busy or enters slave mode. The BUSY bit is cleared by the completion of any of the above states, and by disabling the module. BUSY is a read only bit. It must always be written with 0. 0 – ACB module is not busy. 1 – ACB module is busy. The Bus Busy bit indicates the bus is busy. It is set when the bus is active (i.e., a low level on either SDA or SCL) or by a Start Condition. It is cleared when the module is disabled, on detection of a Stop Condition, or when writing 1 to this bit. See “Usage Hints” on page 162 for a description of the use of this bit. This bit should be set when either the SDA or SCL signals are low. This is done by sampling the SDA and SCL signals continuously and setting the bit if one of them is low. The bit remains set until cleared by a STOP condition or written with 1. 0 – Bus is not busy. 1 – Bus is busy. The Address Match bit indicates in slave mode when ACBADDR.SAEN is set and the first seven bits of the address byte (the first byte transferred after a Start Condition) matches the 7-bit address in the ACBADDR register, or when ACBADDR2.SAEN is set and the first seven bits of the address byte matches the 7-bit address in the ACBADDR2 register. It is cleared by Start Condition or repeated Start and Stop Condition (including illegal Start or Stop Condition). 0 – No address match occurred. 1 – Address match occurred. www.national.com CP3CN23 NEGACK CP3CN23 GCMTCH TSDA TGSCL The Global Call Match bit is set in slave mode when the ACBCTL1.GCMEN bit is set and the address byte (the first byte transferred after a Start Condition) is 00h. It is cleared by a Start Condition or repeated Start and Stop Condition (including illegal Start or Stop Condition). 0 – No global call match occurred. 1 – Global call match occurred. The Test SDA bit samples the state of the SDA signal. This bit can be used while recovering from an error condition in which the SDA signal is constantly pulled low by a slave that went out of sync. This bit is a read-only bit. Data written to it is ignored. The Toggle SCL bit enables toggling the SCL signal during error recovery. When the SDA signal is low, writing 1 to this bit drives the SCL signal high for one cycle. Writing 1 to TGSCL when the SDA signal is high is ignored. The bit is cleared when the clock toggle is completed. 0 – Writing 0 has no effect. 1 – Writing 1 toggles the SDA signal high for one cycle. 22.3.4 The ACBCTL1 register is a byte-wide, read/write register that configures and controls the ACB module. At reset and while the module is disabled (ACBCTL2.ENABLE = 0), the ACBCTL1 register is cleared. 7 6 5 4 3 2 1 0 STASTRE NMINTE GCMEN ACK Res. INTEN STOP START START STOP www.national.com ACB Control Register 1 (ACBCTL1) 160 The Start bit is set to generate a Start Condition on the ACCESS.bus. The START bit is cleared when the Start Condition is sent, or upon detection of a Bus Error (ACBST.BER = 1). This bit should be set only when in Master mode, or when requesting Master mode. If this device is not the active master of the bus (ACBST.MASTER = 0), setting the START bit generates a Start Con0dition as soon as the ACCESS.bus is free (ACBCST.BB = 0). An address send sequence should then be performed. If this device is the active master of the bus (ACBST.MASTER = 1), when the START bit is set, a write to the ACBSDA register generates a Start Condition, then the ACBSDA data is transmitted as the slave’s address and the requested transfer direction. This case is a repeated Start Condition. It may be used to switch the direction of the data flow between the master and the slave, or to choose another slave device without using a Stop Condition in between. 0 – Writing 0 has no effect. 1 – Writing 1 generates a Start condition. The Stop bit in master mode generates a Stop Condition that completes or aborts the current message transfer. This bit clears itself after the Stop condition is issued. 0 – Writing 0 has no effect. 1 – Writing 1 generates a Stop condition. ACK GCMEN NMINTE STASTRE The Interrupt Enable bit controls generating ACB interrupts. When the INTEN bit is cleared ACB interrupt is disabled. When the INTEN bit is set, interrupts are enabled. 0 – ACB interrupts disabled. 1 – ACB interrupts enabled. An interrupt is generated (the interrupt signals to the ICU is high) on any of the following events: An address MATCH is detected (ACBST.NMATCH = 1) and the NMINTE bit is set. A Bus Error occurs (ACBST.BERR = 1). Negative acknowledge after sending a byte (ACBST.NEGACK = 1). An interrupt is generated on acknowledge of each transaction (same as hardware setting the ACBST.SDAST bit). If ACBCTL1.STASTRE = 1, in master mode after a successful start (ACBST.STASTR = 1). Detection of a Stop Condition while in slave receive mode (ACBST.SLVSTP = 1). The Acknowledge bit holds the value this device sends in master or slave mode during the next acknowledge cycle. Setting this bit to 1 instructs the transmitting device to stop sending data, since the receiver either does not need, or cannot receive, any more data. This bit is cleared after the first acknowledge cycle. This bit is ignored when in transmit mode. The Global Call Match Enable bit enables the match of an incoming address byte to the general call address (Start Condition followed by address byte of 00h) while the ACB is in slave mode. When cleared, the ACB does not respond to a global call. 0 – Global call matching disabled. 1 – Global call matching enabled. The New Match Interrupt Enable controls whether ACB interrupts are generated on new matches. Set the NMINTE bit to enable the interrupt on a new match (i.e., when ACBST.NMATCH is set). The interrupt is issued only if the ACBCTL1.INTEN bit is set. 0 – New match interrupts disabled. 1 – New match interrupts enabled. The Stall After Start Enable bit enables the stall after start mechanism. When enabled, the ACB is stalled after the address byte. When the STASTRE bit is clear, the ACBST.STASTR bit is always clear. 0 – No stall after start. 1 – Stall-after-start enabled. 22.3.5 ACB Control Register 2 (ACBCTL2) The ACBCTL2 register is a byte-wide, read/write register that controls the module and selects the ACB clock rate. At reset, the ACBCTL2 register is cleared. 7 1 0 SCLFRQ6:0 ENABLE The Enable bit controls the ACB module. When this bit is set, the ACB module is enabled. When the Enable bit is clear, the ACB module is disabled, the ACBCTL1, ACBST, and ACBCST registers are cleared, and the clocks are halted. 0 – ACB module disabled. 1 – ACB module enabled. The SCL Frequency field specifies the SCL period (low time and high time) in master mode. The clock low time and high time are defined as follows: tSCLl = tSCLh = 2 × SCLFRQ × tCLK Where tCLK is this device’s clock period when in Active mode. The SCLFRQ field may be programmed to values in the range of 0001000b through 1111111b. Using any other value has unpredictable results. SCLFRQ 22.3.6 ENABLE ACB Control Register 3 (ACBCTL3) The ACBCTL3 register is a byte-wide, read/write register that expands the clock prescaler field and enables ARP matches. At reset, the ACBCTL3 register is cleared. 7 3 Reserved ARPMEN SCLFRQ 161 2 ARPMEN 1 0 SCLFRQ8:7 The ARP Match Enable bit enables the matching of an incoming address byte to the SMBus ARP address 110 0001b general call address (Start condition followed by address byte of 00h), while the ACB is in slave mode. 0 – ACB does not respond to ARP addresses. 1 – ARP address matching enabled. The SCL Frequency field specifies the SCL period (low time and high time) in master mode. The ACBCTL3 register provides a 2-bit expansion of this field, with the remaining 7 bits being held in the ACBCTL2 register. www.national.com CP3CN23 INTEN CP3CN23 22.3.7 22.4 ACB Own Address Register 1 (ACBADDR1) The ACBADDR1 register is a byte-wide, read/write register that holds the module’s first ACCESS.bus address. After reset, its value is undefined. 7 6 0 SAEN ADDR ADDR The Own Address field holds the first 7-bit ACCESS.bus address of this device. When in slave mode, the first 7 bits received after a Start Condition are compared to this field (first bit received to bit 6, and the last to bit 0). If the address field matches the received data and the SAEN bit is set, a match is detected. The Slave Address Enable bit controls whether address matching is performed in slave mode. When set, the SAEN bit indicates that the ADDR field holds a valid address and enables the match of ADDR to an incoming address byte. When cleared, the ACB does not check for an address match. 0 – Address matching disabled. 1 – Address matching enabled0. SAEN 22.3.8 ACB Own Address Register 2 (ACBADDR2) The ACBADDR2 register is a byte-wide, read/write register that holds the module’s second ACCESS.bus address. After reset, its value is undefined. 7 6 0 SAEN ADDR SAEN ADDR The Own Address field holds the second 7-bit ACCESS.bus address of this device. When in slave mode, the first 7 bits received after a Start Condition are compared to this field (first bit received to bit 6, and the last to bit 0). If the address field matches the received data and the SAEN bit is set, a match is detected. The Slave Address Enable bit controls whether address matching is performed in slave mode. When set, the SAEN bit indicates that the ADDR field holds a valid address and enables the match of ADDR to an incoming address byte. When cleared, the ACB does not check for an address match. 0 – Address matching disabled. 1 – Address matching enabled. www.national.com USAGE HINTS When the ACB module is disabled, the ACBCST.BB bit is cleared. After enabling the ACB (ACBCTL2.ENABLE = 1) in systems with more than one master, the bus may be in the middle of a transaction with another device, which is not reflected in the BB bit. There is a need to allow the ACB to synchronize to the bus activity status before issuing a request to become the bus master, to prevent bus errors. Therefore, before issuing a request to become the bus master for the first time, software should check that there is no activity on the bus by checking the BB bit after the bus allowed time-out period. When waking up from power down, before checking the ACBCST.MATCH bit, test the ACBCST.BUSY bit to make sure that the address transaction has finished. The BB bit is intended to solve a deadlock in which two, or more, devices detect a usage conflict on the bus and both devices cease being bus masters at the same time. In this situation, the BB bits of both devices are active (because each deduces that there is another master currently performing a transaction, while in fact no device is executing a transaction), and the bus would stay locked until some device sends a ACBCTL1.STOP condition. The ACBCST.BB bit allows software to monitor bus usage, so it can avoid sending a STOP signal in the middle of the transaction of some other device on the bus. This bit detects whether the bus remains unused over a certain period, while the BB bit is set. In some cases, the bus may get stuck with the SCL or SDA lines active. A possible cause is an erroneous Start or Stop Condition that occurs in the middle of a slave receive session. When the SCL signal is stuck active, there is nothing that can be done, and it is the responsibility of the module that holds the bus to release it. When the SDA signal is stuck active, the ACB module enables the release of the bus by using the following sequence. Note that in normal cases, the SCL signal may be toggled only by the bus master. This protocol is a recovery scheme which is an exception that should be used only in the case when there is no other master on the bus. The recovery scheme is as follows: 1. Disable and re-enable the module to set it into the not addressed slave mode. 2. Set the ACBCTL1.START bit to make an attempt to issue a Start Condition. 3. Check if the SDA signal is active (low) by reading ACBCST.TSDA bit. If it is active, issue a single SCL cycle by writing 1 to ACBCST.TGSCL bit. If the SDA line is not active, continue from step 5. 4. Check if the ACBST.MASTER bit is set, which indicates that the Start Condition was sent. If not, repeat step 3 and 4 until the SDA signal is released. 5. Clear the BB bit. This enables the START bit to be executed. Continue according to “Bus Idle Error Recovery” on page 157. 162 Avoiding Bus Error During Write Transaction A Bus Error (BER) may occur during a write transaction if the data register is written at a very specific time. The module generates one system-clock cycle setup time of SDA to SCL vs. the minimum time of the clock divider ratio. The problem can be masked within the driver by dynamically dividing-by-half the SCL width immediately after the slave address is successfully sent and before writing to the ACBSDA register. This has the effect of forcing SCL into the stretch state. The following code example is the relevant segment of the ACCESS.bus driver addressing this issue. /*%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%% ; NAME: ACBRead Reads "Count" byte(s) from selected I2C Slave. If read address differs from previous ; Read or Write operation (as recorded in NextAddress), a "dummy" write transaction is ; initiated to reset the address to the desired location. This is followed by a repeated ; Start sequence and the Read transaction. All transactions begin with a call to ACBStartX ; which sends the Start condition and Slave address. Checks for errors throughout process. ; ; PARAMETERS: UBYTE Slave Slave Device Address. Must be of format 0xXXXX0000 ; UWORD Addrs Byte/Array address (extended addressing mode uses two byte address) ; UWORD Count Number of bytes to read ; UBYTE *buf Pointer to receive buffer ; ; CALLS: ACBStartX ; ; RETURNED: error status ;%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%*/ UWORD ACBRead (UBYTE Slave, UWORD Addrs, UWORD Count, UBYTE *buf) { ACB_T *acb; UBYTE err, *rcv; UWORD Timeout; acb = (ACB_T*)ACB_ADDRESS; /* Set pointer to ACB module /* If the indicated address differs from the last */ */ /* recorded access (i.e. Random Read), we must first /* send a "dummy" write to the desired new address.. /* Update last address placeholder */ */ */ if (Addrs != NextAddress) { NextAddress = Addrs; KeyInit(); KBD_OUT &= ~BIT0; /* Send start bit and Slave address... if ((err = ACBStartX (Slave | (Addrs >> 7 & 0x0E), ACB_WRITE, 0))) return (err); // */ /* If unsuccessful, return error code */ /* Send new address byte */ KBD_OUT &= ~BIT0; acb->ACBsda = (UBYTE)Addrs; KBD_OUT &= ~BIT0; Timeout = 1000; /* Set timeout /* Wait for xmitter to be ready...zzzzzzzzz while (!(acb->ACBst & ACBSDAST) && !(acb->ACBst & ACBBER) && Timeout--); */ */ if (acb->ACBst & ACBBER) { acb->ACBst |= ACBBER; /* If a bus error occurs while sending address, clear /* the error flag and return error status */ */ /* If we timeout, return error */ return (ACBERR_COLLISION); } KBD_OUT &= ~BIT0; if (!Timeout) return (ACBERR_TIMEOUT); } /* (Re)Send start bit and Slave address... if ((err = ACBStartX (Slave | (Addrs >> 7 & 0x0E), ACB_READ, Count))) /* If error, return return (err); */ rcv = /* Get address of read buffer /* Read Count bytes into user’s buffer */ */ /* If this the final byte, or only one requested, send /* the NACK bit after reception */ */ /* Set timeout */ buf; */ while (Count) { if (Count-- == 1) acb->ACBctl1 Timeout = |= ACBACK; 1000; while (!(acb->ACBst & ACBSDAST) && Timeout--); if (!Timeout) /* Timed out?? /* YES - return error */ */ /* NO - Read byte from Recv register /* Adjust current address placeholder */ */ return (ACBERR_TIMEOUT); *rcv++ = acb->ACBsda; NextAddress++; } 163 www.national.com CP3CN23 22.4.1 CP3CN23 acb->ACBctl1 |= ACBSTOP; /* Send STOP bit /* Return success status.... */ */ return (ACB_NOERR); } /*%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%% ; NAME: ACBStartX Initiates an ACB bus transaction by sending the Start bit, followed by the Slave address ; and R/W flag. Checks for any ACB errors throughout this sequence and returns status. ; ; PARAMETERS: UBYTE Slave I2C address of Slave device ; UBYTE R_nW Read/Write flag (0x01 or 0x00) ; UWORD Count Desired number of bytes (read/write) ; ; CALLS: ; ; RETURNED: error/success ;%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%*/ UWORD ACBStartX (UBYTE Slave, UBYTE R_nW, UWORD Count) { ACB_T *acb; UWORD Timeout; /* Get address of ACB module acb = (ACB_T*)ACB_ADDRESS; /* If Bus is Busy and we’re NOT the Master, return err if (acb->ACBcst & ACBBB && !(acb->ACBst & ACBMASTER)) return (ACBERR_NOTMASTER); /* If we’re good to go, send Start condition acb->ACBctl1 |= ACBSTART; /* Check if we’re the Bus Master with timeout Timeout = 100; while (!(acb->ACBst & ACBSDAST) && Timeout--) { if (acb->ACBst & ACBBER) { acb->ACBst |= */ */ */ */ /* Related to bus error problem */ /* If collision occurs, clear error and return status */ ACBBER; return (ACBERR_COLLISION); } } if (!Timeout) return (ACBERR_NOTMASTER); acb->ACBsda = Timeout = Slave | R_nW; 1000; /* If timeout, we must NOT be the Master...signal error */ /* Now, send the address and R/W flag... /* Send address and R/W flag */ */ /* Failsafe for lockup /* Wait for address to be sent and ACK’d */ */ /* If a bus error occurs while sending address, clear /* the error flag and return error status */ */ /* If timeout, signal error */ /* Or if Slave does not reply, report busy/error */ /* Otherwise return success */ while (!(acb->ACBst & ACBSDAST) && !(acb->ACBst & ACBNEGACK)&& --Timeout) { if (acb->ACBst & ACBBER) { acb->ACBst |= ACBBER; return (ACBERR_COLLISION); } } KBD_OUT |= BIT0; // OScope marker if (!Timeout) return (ACBERR_TIMEOUT); else if (acb->ACBst & ACBNEGACK) return (ACBERR_NEGACK); else { return (ACB_NOERR); } www.national.com 164 The Timing and Watchdog Module (TWM) generates the clocks and interrupts used for timing periodic functions in the system; it also provides Watchdog protection over software execution. Slow Clock period. The prescaled clock signal is called T0IN. The TWM is designed to provide flexibility in system design by configuring various clock ratios and by selecting the Watchdog clock source. After setting the TWM configuration, software can lock it for a higher level of protection against erroneous software action. Once the TWM is locked, only reset can release it. Timer T0 is a programmable 16-bit down counter that can be used as the time base for real-time operations such as a periodic audible tick. It can also be used to drive the Watchdog circuit. 23.1 TWM STRUCTURE Figure 78 is a block diagram showing the internal structure of the Timing and Watchdog module. There are two main sections: the Real-Time Timer (T0) section at the top and the Watchdog section on the bottom. All counting activities of the module are based on the Slow Clock (SLCLK). A prescaler counter divides this clock to make a slower clock. The prescaler factor is defined by a 3bit field in the Timer and Watchdog Prescaler register, which selects either 1, 2, 4, 8, 16, or 32 as the divisor. Therefore, the prescaled clock period can be 2, 4, 8, 16, or 32 times the 23.2 TIMER T0 OPERATION The timer starts counting from the value loaded into the TWMT0 register and counts down on each rising edge of T0IN. When the timer reaches zero, it is automatically reloaded from the TWMT0 register and continues counting down from that value. Therefore, the frequency of the timer is: f SLCLK f TIMER = ----------------------------------------------------------------------( TWTM0 + 1 ) × prescaler When an external crystal oscillator is used as the SLCLK source or when the fast clock is divided accordingly, fSLCLK is 32.768 kHz. The value stored in TWMT0 can range from 0001h to FFFFh. REAL TIME TIMER (T0) Slow Clock 5-Bit Prescaler Counter (TWCP) TWW/MT0 Register T0IN T0CSR Contrl. Reg. T0LINT (to ICU) Restart 16-Bit Timer (Timer0) Underflow WATCHDOG Timer Underflow T0OUT (to Multi-InputWake-Up) Restart WDSDM WATCHDOG Service Logic WDCNT Watchdog Error WDERR WATCHDOG DS080 Figure 78. Timing and Watchdog Module Block Diagram When the counter reaches zero, an internal timer signal called T0OUT is set for one T0IN clock cycle. This signal sets the TC bit in the TWMT0 Control and Status Register (T0CSR). It also generates an interrupt (IRQ14), when enabled by the T0CSR.T0INTE bit. T0OUT is also an input to the MIWU (see Section 13.0), so an edge-triggered interrupt is also available through this alternative mechanism. can restart the timer at any time (on the very next edge of the T0IN clock) by setting the Restart (RST) bit in the T0CSR register. The T0CSR.RST bit is cleared automatically upon restart of the 16-bit timer. Note: To enter Power Save or Idle mode after setting the T0CSR.RST bit, software must wait for the reset operation to complete before performing the switch. If software loads the TWMT0 register with a new value, the timer uses that value the next time that it reloads the 16-bit timer register (in other words, after reaching zero). Software 165 www.national.com CP3CN23 23.0 Timing and Watchdog Module CP3CN23 23.3 WATCHDOG OPERATION 23.3.2 The Watchdog is an 8-bit down counter that operates on the rising edge of a specified clock source. At reset, the Watchdog is disabled; it does not count and no Watchdog signal is generated. A write to either the Watchdog Count (WDCNT) register or the Watchdog Service Data Match (WDSDM) register starts the counter. The Watchdog counter counts down from the value programmed in the WDCNT register. Once started, only a reset can stop the Watchdog from operating. The Watchdog can be programmed to use either T0OUT or T0IN as its clock source (the output and input of Timer T0, respectively). The TWCFG.WDCT0I bit controls this clock selection. Software must periodically “service” the Watchdog. There are two ways to service the Watchdog, the choice depending on the programmed value of the WDSDME bit in the Timer and Watchdog Configuration (TWCFG) register. If the TWCFG.WDSDME bit is clear, the Watchdog is serviced by writing a value to the WDCNT register. The value written to the register is reloaded into the Watchdog counter. The counter then continues counting down from that value. Power Save Mode Operation The Timer and Watchdog Module is active in both the Power Save and Idle modes. The clocks and counters continue to operate normally in these modes. The WDSDM register is accessible in the Power Save and Idle modes, but the other TWM registers are accessible only in the Active mode. Therefore, Watchdog servicing must be carried out using the WDSDM register in the Power Save or Idle mode. In the Halt mode, the entire device is frozen, including the Timer and Watchdog Module. On return to Active mode, operation of the module resumes at the point at which it was stopped. Note: After a restart or Watchdog service through WDCNT, do not enter Power Save mode for a period equivalent to 5 Slow Clock cycles. 23.4 TWM REGISTERS The TWM registers controls the operation of the Timing and Watchdog Module. There are six such registers: If the TWCFG.WDSDME bit is set, the Watchdog is serviced by writing the value 5Ch to the Watchdog Service Data Match (WDSDM) register. This reloads the Watchdog counter with the value previously programmed into the WDCNT register. The counter then continues counting down from that value. A Watchdog error signal is generated by any of the following events: The Watchdog serviced too late. The Watchdog serviced too often. The WDSDM register is written with a value other than 5Ch when WDSDM type servicing is enabled (TWCFG.WDSDME = 1). Table 66 TWM Registers Name Address Description TWCFG FF FF20h Timer and Watchdog Configuration Register TWCP FF FF22h Timer and Watchdog Clock Prescaler Register TWMT0 FF FF24h TWM Timer 0 Register T0CSR FF FF26h TWMT0 Control and Status Register WDCNT FF FF28h Watchdog Count Register WDSDM FF FF2Ah Watchdog Service Data Match Register A Watchdog error condition resets the device. 23.3.1 Register Locking The Timer and Watchdog Configuration (TWCFG) register is used to set the Watchdog configuration. It controls the The WDSDM register is accessible in both Active and PowWatchdog clock source (T0IN or T0OUT), the type of er Save mode. The other TWM registers are accessible only Watchdog servicing (using WDCNT or WDSDM), and the in Active mode. locking state of the TWCFG, TWCPR, TIMER0, T0CSR, and WDCNT registers. A register that is locked cannot be read or written. A write operation is ignored and a read operation returns unpredictable results. If the TWCFG register is itself locked, it remains locked until the device is reset. Any other locked registers also remain locked until the device is reset. This feature prevents a runaway program from tampering with the programmed Watchdog function. www.national.com 166 Timer and Watchdog Configuration Register (TWCFG) 23.4.2 The TWCFG register is a byte-wide, read/write register that selects the Watchdog clock input and service method, and also allows the Watchdog registers to be selectively locked. A locked register cannot be read or written; a read operation returns unpredictable values and a write operation is ignored. Once a lock bit is set, that bit cannot be cleared until the device is reset. At reset, the non-reserved bits of the register are cleared. The register format is shown below. Timer and Watchdog Clock Prescaler Register (TWCP) The TWCP register is a byte-wide, read/write register that specifies the prescaler value used for dividing the low-frequency clock to generate the T0IN clock. At reset, the nonreserved bits of the register are cleared. The register format is shown below. 7 3 2 0 Reserved 7 6 5 4 3 2 1 0 Res. WDSDME WDCT0I LWDCNT LTWMT0 LTWCP LTWCFG LTWCFG LTWCP LTWMT0 LWDCNT WDCT0I WDSDME MDIV The Lock TWCFG Register bit controls access to the TWCFG register. When clear, access to the TWCFG register is allowed. When set, the TWCFG register is locked. 0 – TWCFG register unlocked. 1 – TWCFG register locked. The Lock TWCP Register bit controls access to the TWCP register. When clear, access to the TWCP register is allowed. When set, the TWCP register is locked. 0 – TWCP register unlocked. 1 – TWCP register locked. The Lock TWMT0 Register bit controls access to the TWMT0 register. When clear, access to the TWMT0 and T0CSR registers are allowed. When set, the TWMT0 and T0CSR registers are locked. 0 – TWMT0 register unlocked. 1 – TWMT0 register locked. The Lock LDWCNT Register bit controls access to the LDWCNT register. When clear, access to the LDWCNT register is allowed. When set, the LDWCNT register is locked. 0 – LDWCNT register unlocked. 1 – LDWCNT register locked. The Watchdog Clock from T0IN bit selects the clock source for the Watchdog timer. When clear, the T0OUT signal (the output of Timer T0) is used as the Watchdog clock. When set, the T0IN signal (the prescaled Slow Clock) is used as the Watchdog clock. 0 – Watchdog timer is clocked by T0OUT. 1 – Watchdog timer is clocked by T0IN. The Watchdog Service Data Match Enable bit controls which method is used to service the Watchdog timer. When clear, Watchdog servicing is accomplished by writing a count value to the WDCNT register; write operations to the Watchdog Service Data Match (WDSDM) register are ignored. When set, Watchdog servicing is accomplished by writing the value 5Ch to the WDSDM register. 0 – Write a count value to the WDCNT register to service the Watchdog timer. 1 – Write 5Ch to the WDSDM register to service the Watchdog timer. MDIV 23.4.3 Main Clock Divide. This 3-bit field defines the prescaler factor used for dividing the low speed device clock to create the T0IN clock. The allowed 3-bit values and the corresponding clock divisors and clock rates are listed below. MDIV Clock Divisor (fSCLK = 32.768 kHz) T0IN Frequency 000 1 32.768 kHz 001 2 16.384 kHz 010 4 8.192 kHz 011 8 4.096 kHz 100 16 2.056 kHz 101 32 1.024 kHz Other Reserved N/A TWM Timer 0 Register (TWMT0) The TWMT0 register is a word-wide, read/write register that defines the T0OUT interrupt rate. At reset, TWMT0 register is initialized to FFFFh. The register format is shown below. 15 0 PRESET PRESET 167 The Timer T0 Preset field holds the value used to reload Timer T0 on each underflow. Therefore, the frequency of the Timer T0 interrupt is the frequency of T0IN divided by (PRESET+1). The allowed values of PRESET are 0001h through FFFFh. www.national.com CP3CN23 23.4.1 CP3CN23 23.4.4 TWMT0 Control and Status Register (T0CSR) 23.4.5 The T0CSR register is a byte-wide, read/write register that controls Timer T0 and shows its current status. At reset, the non-reserved bits of the register are cleared. The register format is shown below. 7 5 Reserved 4 3 FRZT0E WDLTD 2 1 0 T0INTE TC RST Watchdog Count Register (WDCNT) The WDCNT register is a byte-wide, write-only register that holds the value that is loaded into the Watchdog counter each time the Watchdog is serviced. The Watchdog is started by the first write to this register. Each successive write to this register restarts the Watchdog count with the written value. At reset, this register is initialized to 0Fh. 7 0 PRESET RST TC T0INTE WDLTD FRZT0E The Restart bit is used to reset Timer T0. When this bit is set, it forces the timer to reload the value in the TWMT0 register on the next rising edge of the selected input clock. The RST bit is reset automatically by the hardware on the same rising edge of the selected input clock. Writing a 0 to this bit position has no effect. At reset, the non-reserved bits of the register are cleared. 0 – Writing 0 has no effect. 1 – Writing 1 resets Timer T0. The Terminal Count bit is set by hardware when the Timer T0 count reaches zero and is cleared when software reads the T0CSR register. It is a read-only bit. Any data written to this bit position is ignored. The TC bit is not cleared if FREEZE mode is asserted by an external debugging system. 0 – Timer T0 did not count down to 0. 1 – Timer T0 counted down to 0. The Timer T0 Interrupt Enable bit enables an interrupt to the CPU each time the Timer T0 count reaches zero. When this bit is clear, Timer T0 interrupts are disabled. 0 – Timer T0 interrupts disabled. 1 – Timer T0 interrupts enabled. The Watchdog Last Touch Delay bit is set when either WDCNT or WDSDM is written and the data transfer to the Watchdog is in progress (see WDCNT and WDSDM register description). When clear, it is safe to switch to Power Save mode. 0 – No data transfer to the Watchdog is in progress, safe to enter Power Save mode. 1 – Data transfer to the Watchdog in progress. The Freeze Timer0 Enable bit controls whether TImer 0 is stopped in FREEZE mode. If this bit is set, the Timer 0 is frozen (stopped) when the FREEZE input to the TWM is asserted. If the FRZT0E bit is clear, only the Watchdog timer is frozen by asserting the FREEZE input signal. After reset, this bit is clear. 0 – Timer T0 unaffected by FREEZE mode. 1 – Timer T0 stopped in FREEZE mode. www.national.com 23.4.6 Watchdog Service Data Match Register (WDSDM) The WSDSM register is a byte-wide, write-only register used for servicing the Watchdog. When this type of servicing is enabled (TWCFG.WDSDME = 1), the Watchdog is serviced by writing the value 5Ch to the WSDSM register. Each such servicing reloads the Watchdog counter with the value previously written to the WDCNT register. Writing any data other than 5Ch triggers a Watchdog error. Writing to the register more than once in one Watchdog clock cycle also triggers a Watchdog error signal. If this type of servicing is disabled (TWCFG.WDSDME = 0), any write to the WSDSM register is ignored. 7 0 RSTDATA 23.5 WATCHDOG PROGRAMMING PROCEDURE The highest level of protection against software errors is achieved by programming and then locking the Watchdog registers and using the WDSDM register for servicing. This is the procedure: 168 1. Write the desired values into the TWM Clock Prescaler register (TWCP) and the TWM Timer 0 register (TWMT0) to control the T0IN and T0OUT clock rates. The frequency of T0IN can be programmed to any of six frequencies ranging from 1/32 × fSLCLK to fSLCLK. The frequency of T0OUT is equal to the frequency of T0IN divided by (1+ PRESET), in which PRESET is the value written to the TWMT0 register. 2. Configure the Watchdog clock to use either T0IN or T0OUT by setting or clearing the TWCFG.WDCT0I bit. 3. Write the initial value into the WDCNT register. This starts operation of the Watchdog and specifies the maximum allowed number of Watchdog clock cycles between service operations. 4. Set the T0CSR.RST bit to restart the TWMT0 timer. 5. Lock the Watchdog registers and enable the Watchdog Service Data Match Enable function by setting bits 0, 1, 2, 3, and 5 in the TWCFG register. 6. Service the Watchdog by periodically writing the value 5Ch to the WDSDM register at an appropriate rate. Servicing must occur at least once per period programmed into the WDCNT register, but no more than once in a single Watchdog input clock cycle. Processor-Independent Pulse Width Modulation (PWM) mode, which generates pulses of a specified width and duty cycle, and which also provides a general-purpose timer/counter. Dual-Input Capture mode, which measures the elapsed time between occurrences of external events, and which also provides a general-purpose timer/counter. Dual Independent Timer mode, which generates system timing signals or counts occurrences of external events. The timer unit uses two I/O pins, called TA and TB. The timer I/O pins are alternate functions of the PG7 and PE4 port pins, respectively. 24.1 TIMER STRUCTURE Figure 79 is a block diagram showing the internal structure of the MFT. There are two main functional blocks: a Timer/ Counter and Action block and a Clock Source block. The Timer/Counter and Action block contains two separate timer/counter units, called Timer/Counter 1 and Timer/Counter 2. Timer/Counter Clock Source Action Reload/Capture A TCRA Clock Prescaler/Selector System Clock Single-Input Capture and Single Timer mode, which provides one external event counter and one system timer. Timer/Counter 1 TCNT1 Reload/Capture B TCRB Timer/Counter 2 TCNT2 External Event Toggle/Capture/Interrupt The Multi-Function Timer module contains a pair of 16-bit timer/counters. Each timer/counter unit offers a choice of clock sources for operation and can be configured to operate in any of the following modes: TA Interrupt A Interrupt B TB PWM/Capture/Counter Mode Select + Control DS081 Figure 79. Multi-Function Timer Block Diagram 24.1.1 Timer/Counter Block The Timer/Counter block contains the following functional blocks: Two 16-bit counters, Timer/Counter 1 (TCNT1) and Timer/Counter 2 (TCNT2) Two 16-bit reload/capture registers, TCRA and TCRB Control logic necessary to configure the timer to operate in any of the four operating modes Interrupt control and I/O control logic 24.1.2 Clock Source Block The Clock Source block generates the signals used to clock the two timer/counter registers. The internal structure of the Clock Source block is shown in Figure 80. No Clock Prescaler Register TPRSC Reset System Clock In a power-saving mode that uses the low-frequency (32.768 kHz) clock as the System Clock, the synchronization circuit requires that the Slow Clock operate at no more than one-fourth the speed of the 32.768 kHz System Clock. Counter 1 Clock Counter 2 Clock Select Counter 2 Clock Prescaled Clock 5-Bit Prescaler Counter Pulse Accumulator TB Counter 1 Clock Select External Event Synchr. DS082 Figure 80. Multi-Function Timer Clock Source 169 www.national.com CP3CN23 24.0 Multi-Function Timer CP3CN23 Counter Clock Source Select External Event Clock There are two clock source selectors that allow software to The TB I/O pin can be configured to operate as an external independently select the clock source for each of the two event input clock for either of the two 16-bit counters. This 16-bit counters from any one of the following sources: input can be programmed to detect either rising or falling edges. The minimum pulse width of the external signal is No clock (which stops the counter) one System Clock cycle. This means that the maximum fre Prescaled System Clock quency at which the counter can run in this mode is one-half External event count based on TB of the System Clock frequency. This clock source is not Pulse accumulate mode based on TB Slow Clock (derived from the low-frequency oscillator or available in the capture modes (modes 2 and 4) because the TB pin is used as one of the two capture inputs. divided from the high-speed oscillator) Prescaler Pulse Accumulate Mode The 5-bit clock prescaler allows software to run the timer with a prescaled clock signal. The prescaler consists of a 5bit read/write prescaler register (TPRSC) and a 5-bit down counter. The System Clock is divided by the value contained in the prescaler register plus 1. Therefore, the timer clock period can be set to any value from 1 to 32 divisions of the System Clock period. The prescaler register and down counter are both cleared upon reset. The counter can also be configured to count prescaler output clock pulses when the TB input is high and not count when the TB input is low, as illustrated in Figure 81. The resulting count is an indicator of the cumulative time that the TB input is high. This is called the “pulse-accumulate” mode. In this mode, an AND gate generates a clock signal for the counter whenever a prescaler clock pulse is generated and the TB input is high. (The polarity of the TB signal is programmable, so the counter can count when the TB input is low rather than high.) The pulse-accumulate mode is not available in the capture modes (modes 2 and 4) because the TB pin is used as one of the two capture inputs. Prescaler Output TB Counter Clock DS083 Figure 81. Pulse-Accumulate Mode Slow Clock The Slow Clock is generated by the Triple Clock and Reset module. The clock source is either the divided fast clock or the external 32.768 kHz crystal oscillator (if available and selected). The Slow Clock can be used as the clock source for the two 16-bit counters. Because the Slow Clock can be asynchronous to the System Clock, a circuit is provided to synchronize the clock signal to the high-frequency System Clock before it is used for clocking the counters. The synchronization circuit requires that the Slow Clock operate at no more than one-fourth the speed of the System Clock. Idle and Halt modes stop the System Clock (the high-frequency and/or low-frequency clock) completely. If the System Clock is stopped, the timer stops counting until the System Clock resumes operation. In the Idle or Halt mode, the System Clock stops completely, which stops the operation of the timers. In that case, the timers stop counting until the System Clock resumes operation. 24.2 TIMER OPERATING MODES Each timer/counter unit can be configured to operate in any of the following modes: Processor-Independent Pulse Width Modulation (PWM) mode The Power Save mode uses the Slow Clock as the System Dual-Input Capture mode Clock. In this mode, the Slow Clock cannot be used as a Dual Independent Timer mode clock source for the timers because that would drive both Single-Input Capture and Single Timer mode clocks at the same frequency, and the clock ratio needed for synchronization to the System Clock would not be main- At reset, the timers are disabled. To configure and start the tained. However, the External Event Clock and Pulse Accu- timers, software must write a set of values to the registers mulate Mode will still work, as long as the external event that control the timers. The registers are described in pulses are at least the size of the whole slow-clock period. Section 24.5. Using the prescaled System Clock will also work, but at a much slower rate than the original System Clock. Limitations in Low-Power Modes www.national.com 170 Mode 1: Processor-Independent PWM The timer can be configured to toggle the TA output bit on Mode 1 is the Processor-Independent Pulse Width Modula- each underflow. This generates a clock signal on the TA outtion (PWM) mode, which generates pulses of a specified put with the width and duty cycle determined by the values width and duty cycle, and which also provides a separate stored in the TCRA and TCRB registers. This is a “processor-independent” PWM clock because once the timer is set general-purpose timer/counter. up, no more action is required from the CPU to generate a Figure 82 is a block diagram of the Multi-Function Timer continuous PWM signal. configured to operate in Mode 1. Timer/Counter 1 (TCNT1) functions as the time base for the PWM timer. It counts The timer can be configured to generate separate interrupts down at the clock rate selected for the counter. When an un- upon reload from the TCRA and TCRB registers. The interderflow occurs, the timer register is reloaded alternately rupts can be enabled or disabled under software control. from the TCRA and TCRB registers, and counting proceeds The CPU can determine the cause of each interrupt by looking at the TAPND and TBPND bits, which are updated by downward from the loaded value. the hardware on each occurrence of a timer reload. On the first underflow, the timer is loaded from the TCRA register, then from the TCRB register on the next underflow, In Mode 1, Timer/Counter 2 (TCNT2) can be used either as then from the TCRA register again on the next underflow, a simple system timer, an external event counter, or a pulseand so on. Every time the counter is stopped and restarted, accumulate counter. The clock counts down using the clock it always obtains its first reload value from the TCRA regis- selected with the Timer/Counter 2 clock selector. It generter. This is true whether the timer is restarted upon reset, af- ates an interrupt upon each underflow if the interrupt is enter entering Mode 1 from another mode, or after stopping abled with the TDIEN bit. and restarting the clock with the Timer/Counter 1 clock selector. Reload A = Time 1 TCRA TAPND Timer Interrupt A Underflow TAIEN Timer 1 Clock Timer/Counter 1 TCNT1 TA TAEN Underflow Timer Interrupt B TBIEN Reload B = Time 2 TCRB Timer 2 Clock TBPND Timer/Counter 2 TCNT2 Timer Interrupt D TDIEN TDPND Clock Selector TB DS084 Figure 82. Processor-Independent PWM Mode 171 www.national.com CP3CN23 24.2.1 CP3CN23 24.2.2 Mode 2: Dual Input Capture The values captured in the TCRA register at different times Mode 2 is the Dual Input Capture mode, which measures reflect the elapsed time between transitions on the TA pin. the elapsed time between occurrences of external events, The same is true for the TCRB register and the TB pin. The and which also provides a separate general-purpose timer/ input signal on the TA or TB pin must have a pulse width equal to or greater than one System Clock cycle. counter. Figure 83 is a block diagram of the Multi-Function Timer configured to operate in Mode 2. The time base of the capture timer depends on Timer/Counter 1, which counts down using the clock selected with the Timer/Counter 1 clock selector. The TA and TB pins function as capture inputs. A transition received on the TA pin transfers the timer contents to the TCRA register. Similarly, a transition received on the TB pin transfers the timer contents to the TCRB register. Each input pin can be configured to sense either rising or falling edges. The TA and TB inputs can be configured to preset the counter to FFFFh on reception of a valid capture event. In this case, the current value of the counter is transferred to the corresponding capture register and then the counter is preset to FFFFh. Using this approach allows software to determine the on-time and off-time and period of an external signal with a minimum of CPU overhead. There are three separate interrupts associated with the capture timer, each with its own enable bit and pending bit. The three interrupt events are reception of a transition on the TA pin, reception of a transition on the TB pin, and underflow of the TCNT1 counter. The enable bits for these events are TAIEN, TBIEN, and TCIEN, respectively. In Mode 2, Timer/Counter 2 (TCNT2) can be used as a simple system timer. The clock counts down using the clock selected with the Timer/Counter 2 clock selector. It generates an interrupt upon each underflow if the interrupt is enabled with the TDIEN bit. Neither Timer/Counter 1 (TCNT1) nor Timer/Counter 2 (TCNT2) can be configured to operate as an external event counter or to operate in the pulse-accumulate mode because the TB input is used as a capture input. Attempting to select one of these configurations will cause one or both counters to stop. Timer Interrupt 1 TAIEN TAPND Capture A TCRA TA Preset TAEN Timer 1 Clock Timer/Counter 1 TCNT1 TCPND Underflow Timer Interrupt 1 TCIEN Preset TBEN Capture B TCRB TB TBPND Timer Interrupt 1 TBIEN TDPND Timer 2 Clock Timer/Counter 2 TnCNT2 Underflow Timer Interrupt 2 TDIEN Figure 83. Dual-Input Capture Mode www.national.com 172 DS085 Mode 3: Dual Independent Timer/Counter Mode 3 is the Dual Independent Timer mode, which generates system timing signals or counts occurrences of external events. Figure 84 is a block diagram of the Multi-Function Timer configured to operate in Mode 3. The timer is configured to operate as a dual independent system timer or dual external event counter. In addition, Timer/Counter 1 can generate a 50% duty cycle PWM signal on the TA pin. The TB pin can be used as an external event input or pulse-accumulate input and can be used as the clock source for either Timer/ Counter 1 or Timer/Counter 2. Both counters can also be clocked by the prescaled System Clock. Timer/Counter 1 (TCNT1) counts down at the rate of the selected clock. On underflow, it is reloaded from the TCRA register and counting proceeds down from the reloaded val- ue. In addition, the TA pin is toggled on each underflow if this function is enabled by the TAEN bit. The initial state of the TA pin is software-programmable. When the TA pin is toggled from low to high, it sets the TCPND interrupt pending bit and also generates an interrupt if enabled by the TAIEN bit. Because the TA pin toggles on every underflow, a 50% duty cycle PWM signal can be generated on the TA pin without any further action from the CPU. Timer/Counter 2 (TCNT2) counts down at the rate of the selected clock. On underflow, it is reloaded from the TCRB register and counting proceeds down from the reloaded value. In addition, each underflow sets the TDPND interrupt pending bit and generates an interrupt if the interrupt is enabled by the TDIEN bit. Reload A TCRA TAPND Timer Interrupt 1 Underflow TAIEN Timer 1 Clock Timer/Counter 1 TCNT1 TA TAEN Reload B TCRB Timer Interrupt 2 Underflow TDIEN Timer 2 Clock Timer/Counter 2 TCNT2 TDPND Clock Selector TB DS086 Figure 84. Dual-Independent Timer/Counter Mode 173 www.national.com CP3CN23 24.2.3 CP3CN23 24.2.4 Mode 4: Input Capture Plus Timer Mode 4 is the Single Input Capture and Single Timer mode, which provides one external event counter and one system timer. Figure 85 is a block diagram of the Multi-Function Timer configured to operate in Mode 4. This mode offers a combination of Mode 3 and Mode 2 functions. Timer/Counter 1 is used as a system timer as in Mode 3 and Timer/Counter 2 is used as a capture timer as in Mode 2, but with a single input rather than two inputs. Timer/Counter 1 (TCNT1) operates the same as in Mode 3. It counts down at the rate of the selected clock. On underflow, it is reloaded from the TCRA register and counting proceeds down from the reloaded value. The TA pin is toggled on each underflow, when this function is enabled by the TAEN bit. When the TA pin is toggled from low to high, it sets the TCPND interrupt pending bit and also generates an interrupt if the interrupt is enabled by the TAIEN bit. A 50% duty cycle PWM signal can be generated on TA without any further action from the CPU. Timer/Counter 2 (TCNT1) counts down at the rate of the selected clock. The TB pin functions as the capture input. A transition received on TB transfers the timer contents to the TCRB register. The input pin can be configured to sense either rising or falling edges. The TB input can be configured to preset the counter to FFFFh on reception of a valid capture event. In this case, the current value of the counter is transferred to the capture register and then the counter is preset to FFFFh. The values captured in the TCRB register at different times reflect the elapsed time between transitions on the TA pin. The input signal on TB must have a pulse width equal to or greater than one System Clock cycle. There are two separate interrupts associated with the capture timer, each with its own enable bit and pending bit. The two interrupt events are reception of a transition on TB and underflow of the TCNT2 counter. The enable bits for these events are TBIEN and TDIEN, respectively. Neither Timer/Counter 1 (TCNT1) nor Timer/Counter 2 (TCNT2) can be configured to operate as an external event counter or to operate in the pulse-accumulate mode because the TB input is used as a capture input. Attempting to select one of these configurations will cause one or both counters to stop. In this mode, Timer/Counter 2 must be enabled at all times. Reload A TCRA TAPND Timer Interrupt 1 Underflow TAIEN Timer 1 Clock Timer/Counter 1 TCNT1 TA TAEN Timer Interrupt 1 TBIEN TBPND Capture B TCRB TB Preset TBEN Timer 2 Clock TDPND Timer/Counter 2 TnCNT2 Timer Interrupt 2 TDIEN Figure 85. www.national.com Input Capture Plus Timer Mode 174 DS087 TIMER INTERRUPTS 24.4 The Multi-Function Timer unit has four interrupt sources, designated A, B, C, and D. Interrupt sources A, B, and C are mapped into a single system interrupt called Timer Interrupt 1, while interrupt source D is mapped into a system interrupt called Timer Interrupt 2. Each of the four interrupt sources has its own enable bit and pending bit. The enable bits are named TAIEN, TBIEN, TCIEN, and TDIEN. The pending bits are named TAPND, TBPND, TCPND, and TDPND. TIMER I/O FUNCTIONS The Multi-Function Timer unit uses two I/O pins, called TA and TB. The function of each pin depends on the timer operating mode and the TAEN and TBEN enable bits. Table 68 shows the functions of the pins in each operating mode, and for each combination of enable bit settings. When the TA pin is configured to operate as a PWM output (TAEN = 1), the state of the pin is toggled on each underflow of the TCNT1 counter. In this case, the initial value on the Timer Interrupts 1 and 2 are system interrupts TA and TB pin is determined by the TAOUT bit. For example, to start (IRQ14 and IRQ13), respectively. with TA high, software must set the TAOUT bit before enTable 67 shows the events that trigger interrupts A, B, C, abling the timer clock. This option is available only when the and D in each of the four operating modes. Note that some timer is configured to operate in Mode 1, 3, or 4 (in other words, when TCRA is not used in Capture mode). interrupt sources are not used in some operating modes. Table 67 Timer Interrupts Overview Sys. Int. Timer Int. 1 (TA Int.) Interrupt Pending Bit Mode 1 Mode 2 Mode 3 Mode 4 PWM + Counter Dual Input Capture + Counter Dual Counter Single Capture + Counter TAPND TCNT1 reload from TCRA Input capture on TA transition TCNT1 reload from TCRA TCNT1 reload from TCRA TBPND TCNT1 reload from TCRB Input Capture on TB transition N/A Input Capture on TB transition TCPND N/A TCNT1 underflow N/A N/A TCNT2 underflow TCNT2 underflow TCNT2 reload from TCRB TCNT2 underflow Timer TDPND Int. 2 (TB Int.) Table 68 Timer I/O Functions I/O TA TB TAEN TBEN Mode 1 Mode 2 Mode 3 Mode 4 PWM + Counter Dual Input Capture + counter Dual Counter Single Capture + counter TAEN = 0 TBEN = X No Output TAEN = 1 TBEN = X Capture TCNT1 into TCRA No Output Toggle No Output Toggle Toggle Output on Capture TCNT1 into Underflow of TCNT1 TCRA and Preset TCNT1 Toggle Output on Underflow of TCNT1 Toggle Output on Underflow of TCNT1 TAEN = X TBEN = 0 Ext. Event or Pulse Accumulate Input Capture TCNT1 into TCRB Ext. Event or Pulse Accumulate Input Capture TCNT2 into TCRB TAEN = X TBEN = 1 Ext. Event or Pulse Accumulate Input Capture TCNT1 into TCRB and Preset TCNT1 Ext. Event or Pulse Accumulate Input Capture TCNT2 into TCRB and Preset TCNT2 175 www.national.com CP3CN23 24.3 CP3CN23 24.5 TIMER REGISTERS 24.5.2 Table 69 lists the CPU-accessible registers used to control the Multi-Function Timers. Table 69 Multi-Function Timer Registers Name Address Description TPRSC FF FF48h Clock Prescaler Register TCKC FF FF4Ah Clock Unit Control Register TCNT1 FF FF40h Timer/Counter 1 Register TCNT2 FF FF46h Timer/Counter 2 Register TCRA FF FF42h Reload/Capture A Register TCRB FF FF44h Reload/Capture B Register TCTRL FF FF4Ch Timer Mode Control Register TICTL FF FF4Eh Timer Interrupt Control Register TICLR FF FF50h Timer Interrupt Clear Register The TCKC register is a byte-wide, read/write register that selects the clock source for each timer/counter. Selecting the clock source also starts the counter. This register is cleared on reset, which disables the timer/counters. The register format is shown below. 7 C2CSEL Clock Prescaler Register (TPRSC) The TPRSC register is a byte-wide, read/write register that holds the current value of the 5-bit clock prescaler (CLKPS). This register is cleared on reset. The register format is shown below. 7 5 Reserved 4 5 3 C2CSEL 2 0 C1CSEL The Counter 1 Clock Select field specifies the clock mode for Timer/Counter 1 as follows: 000 – No clock (Timer/Counter 1 stopped, modes 1, 2, and 3 only). 001 – Prescaled System Clock. 010 – External event on TB (modes 1 and 3 only). 011 – Pulse-accumulate mode based on TB (modes 1 and 3 only). 100 – Slow Clock.* 101 – Reserved. 110 – Reserved. 111 – Reserved. The Counter 2 Clock Select field specifies the clock mode for Timer/Counter 2 as follows: 000 – No clock (Timer/Counter 2 stopped, modes 1, 2, and 3 only). 001 – Prescaled System Clock. 010 – External event on TB (modes 1 and 3 only). 011 – Pulse-accumulate mode based on TB (modes 1 and 3 only). 100 – Slow Clock* 101 – Reserved. 110 – Reserved. 111 – Reserved. * Operation of the Slow Clock is determined by the CRCTRL.SCLK control bit, as described in Section 11.9.1. 0 CLKPS 24.5.3 CLKPS 6 Reserved C1CSEL 24.5.1 Clock Unit Control Register (TCKC) The Clock Prescaler field specifies the divisor used to generate the Timer Clock from the System Clock. When the timer is configured to use the prescaled clock, the System Clock is divided by (CLKPS + 1) to produce the timer clock. Therefore, the System Clock divisor can range from 1 to 32. Timer/Counter 1 Register (TCNT1) The TCNT1 register is a word-wide, read/write register that holds the current count value for Timer/Counter 1. The register contents are not affected by a reset and are unknown after power-up. 15 0 TCNT1 24.5.4 Timer/Counter 2 Register (TCNT2) The TCNT2 register is a word-wide, read/write register that holds the current count value for Timer/Counter 2. The register contents are not affected by a reset and are unknown after power-up. 15 0 TCNT2 www.national.com 176 Reload/Capture A Register (TCRA) TAEN The TCRA register is a word-wide, read/write register that holds the reload or capture value for Timer/Counter 1. The register contents are not affected by a reset and are unknown after power-up. 15 0 TCRA 24.5.6 TBEN Reload/Capture B Register (TCRB) The TCRB register is a word-wide, read/write register that holds the reload or capture value for Timer/Counter 2. The register contents are not affected by a reset and are unknown after power-up. 15 0 TCRB 24.5.7 TAOUT Timer Mode Control Register (TCTRL) The TCTRL register is a byte-wide, read/write register that sets the operating mode of the timer/counter and the TA and TB pins. This register is cleared at reset. The register format is shown below. 7 6 5 4 3 2 1 0 TEN TAOUT TBEN TAEN TBEDG TAEDG MDSEL MDSEL TAEDG TBEDG The Mode Select field sets the operating mode of the timer/counter as follows: 00 – Mode 1: PWM plus system timer. 01 – Mode 2: Dual-Input Capture plus system timer. 10 – Mode 3: Dual Timer/Counter. 11 – Mode 4: Single-Input Capture and Single Timer. The TA Edge Polarity bit selects the polarity of the edges that trigger the TA input. 0 – TA input is sensitive to falling edges (high to low transitions). 1 – TA input is sensitive to rising edges (low to high transitions). The TB Edge Polarity bit selects the polarity of the edges that trigger the TB input. In pulseaccumulate mode, when this bit is set, the counter is enabled only when TB is high; when this bit is clear, the counter is enabled only when TB is low. 0 – TB input is sensitive to falling edges (high to low transitions). 1 – TB input is sensitive to rising edges (low to high transitions). TEN 177 The TA Enable bit controls whether the TA pin is enabled to operate as a preset input or as a PWM output, depending on the timer operating mode. In Mode 2 (Dual Input Capture), a transition on the TA pin presets the TCNT1 counter to FFFFh. In the other modes, TA functions as a PWM output. When this bit is clear, operation of the pin for the timer/counter is disabled. 0 – TA input disabled. 1 – TA input enabled. The TB Enable bit controls whether the TB pin in enabled to operate in Mode 2 (Dual Input Capture) or Mode 4 (Single Input Capture and Single Timer). A transition on the TB pin presets the corresponding timer/counter to FFFFh (TCNT1 in Mode 2 or TCNT2 in Mode 4). When this bit is clear, operation of the pin for the timer/counter is disabled. This bit setting has no effect in Mode 1 or Mode 3. 0 – TB input disabled. 1 – TB input enabled. The TA Output Data bit indicates the current state of the TA pin when the pin is used as a PWM output. The hardware sets and clears this bit, but software can also read or write this bit at any time and therefore control the state of the output pin. In case of conflict, a software write has precedence over a hardware update. This bit setting has no effect when the TA pin is used as an input. 0 – TA pin is low. 1 – TA pin is high. The Timer Enable bit controls whether the Multi-Function Timer is enabled. When the module is disabled all clocks to the counter unit are stopped to minimize power consumption. For that reason, the timer/counter registers (TCNT1 and TCNT2), the capture/reload registers (TCRA and TCRB), and the interrupt pending bits (TXPND) cannot be written in this mode. Also, the 5-bit clock prescaler and the interrupt pending bits are cleared, and the TA I/O pin becomes an input. 0 – Multi-Function Timer is disabled. 1 – Multi-Function Timer is enabled. www.national.com CP3CN23 24.5.5 CP3CN23 24.5.8 Timer Interrupt Control Register (TICTL) TBIEN The TICTL register is a byte-wide, read/write register that contains the interrupt enable bits and interrupt pending bits for the four timer interrupt sources, designated A, B, C, and D. The condition that causes each type of interrupt depends on the operating mode, as shown in Table 67. This register is cleared upon reset. The register format is shown below. 7 6 5 4 3 2 1 TCIEN 0 TDIEN TCIEN TBIEN TAIEN TDPND TCPND TBPND TAPND TAPND TBPND TCPND TDPND TAIEN The Timer Interrupt Source A Pending bit indicates that timer interrupt condition A has occurred. For an explanation of interrupt conditions A, B, C, and D, see Table 67. This bit can be set by hardware or by software. To clear this bit, software must use the Timer Interrupt Clear Register (TICLR). Attempting to directly write a 0 to this bit is ignored. 0 – Interrupt source A has not triggered. 1 – Interrupt source A has triggered. The Timer Interrupt Source B Pending bit indicates that timer interrupt condition B has occurred. For an explanation of interrupt conditions A, B, C, and D, see Table 67. This bit can be set by hardware or by software. To clear this bit, software must use the Timer Interrupt Clear Register (TICLR). Attempting to directly write a 0 to this bit is ignored. 0 – Interrupt source B has not triggered. 1 – Interrupt source B has triggered. The Timer Interrupt Source C Pending bit indicates that timer interrupt condition C has occurred. For an explanation of interrupt conditions A, B, C, and D, see Table 67. This bit can be set by hardware or by software. To clear this bit, software must use the Timer Interrupt Clear Register (TICLR). Attempting to directly write a 0 to this bit is ignored. 0 – Interrupt source C has not triggered. 1 – Interrupt source C has triggered. The Timer Interrupt Source D Pending bit indicates that timer interrupt condition D has occurred. For an explanation of interrupt conditions A, B, C, and D, see Table 67. This bit can be set by hardware or by software. To clear this bit, software must use the Timer Interrupt Clear Register (TICLR). Attempting to directly write a 0 to this bit is ignored. 0 – Interrupt source D has not triggered. 1 – Interrupt source D has triggered. The Timer Interrupt A Enable bit controls whether an interrupt is generated on each occurrence of interrupt condition A. For an explanation of interrupt conditions A, B, C, and D, see Table 67. 0 – Condition A interrupts disabled. 1 – Condition A interrupts enabled. www.national.com TDIEN 24.5.9 The Timer Interrupt B Enable bit controls whether an interrupt is generated on each occurrence of interrupt condition B. For an explanation of interrupt conditions A, B, C, and D, see Table 67. 0 – Condition B interrupts disabled. 1 – Condition B interrupts enabled. The Timer Interrupt C Enable bit controls whether an interrupt is generated on each occurrence of interrupt condition C. For an explanation of interrupt conditions A, B, C, and D, see Table 67. 0 – Condition C interrupts disabled. 1 – Condition C interrupts enabled. The Timer Interrupt D Enable bit controls whether an interrupt is generated on each occurrence of interrupt condition D. For an explanation of interrupt conditions A, B, C, and D, see Table 67. 0 – Condition D interrupts disabled. 1 – Condition D interrupts enabled. Timer Interrupt Clear Register (TICLR) The TICLR register is a byte-wide, write-only register that allows software to clear the TAPND, TBPND, TCPND, and TDPND bits in the Timer Interrupt Control (TICTRL) register. Do not modify this register with instructions that access the register as a read-modify-write operand, such as the bit manipulation instructions. The register reads as FFh. The register format is shown below. 7 4 Reserved TACLR TBCLR TCCLR TDCLR 178 3 2 1 0 TDCLR TCCLR TBCLR TACLR The Timer Pending A Clear bit is used to clear the Timer Interrupt Source A Pending bit (TAPND) in the Timer Interrupt Control register (TICTL). 0 – Writing a 0 has no effect. 1 – Writing a 1 clears the TAPND bit. The Timer Pending A Clear bit is used to clear the Timer Interrupt Source B Pending bit (TBPND) in the Timer Interrupt Control register (TICTL). 0 – Writing a 0 has no effect. 1 – Writing a 1 clears the TBPND bit. The Timer Pending C Clear bit is used to clear the Timer Interrupt Source C Pending bit (TCPND) in the Timer Interrupt Control register (TICTL). 0 – Writing a 0 has no effect. 1 – Writing a 1 clears the TCPND bit. The Timer Pending D Clear bit is used to clear the Timer Interrupt Source D Pending bit (TDPND) in the Timer Interrupt Control register (TICTL). 0 – Writing a 0 has no effect. 1 – Writing a 1 clears the TDPND bit. The Versatile Timer Unit (VTU) contains four fully indepen- The VTU controls a total of eight I/O pins, each of which dent 16-bit timer subsystems. Each timer subsystem can can function as either: operate either as dual 8-bit PWM timers, as a single 16-bit — PWM output with programmable output polarity PWM timer, or as a 16-bit counter with 2 input capture chan— Capture input with programmable event detection and nels. These timer subsystems offers an 8-bit clock prescaler timer reset to accommodate a wide range of system frequencies. A flexible interrupt scheme with — Four separate system level interrupt requests The VTU offers the following features: — A total of 16 interrupt sources each with a separate in The VTU can be configured to provide: terrupt pending bit and interrupt enable bit — Eight fully independent 8-bit PWM channels 25.1 VTU FUNCTIONAL DESCRIPTION — Four fully independent 16-bit PWM channels — Eight 16-bit input capture channels The VTU is comprised of four timer subsystems. Each timer The VTU consists of four timer subsystems, each of subsystem contains an 8-bit clock prescaler, a 16-bit upwhich contains: counter, and two 16-bit registers. Each timer subsystem — A 16-bit counter controls two I/O pins which either function as PWM outputs — Two 16-bit capture / compare registers or capture inputs depending on the mode of operation. — An 8-bit fully programmable clock prescaler There are four system-level interrupt requests, one for each Each of the four timer subsystems can operate in the fol- timer subsystem. Each system-level interrupt request is lowing modes: controlled by four interrupt pending bits with associated en— Low power mode, i.e. all clocks are stopped able/disable bits. All four timer subsystems are fully inde— Dual 8-bit PWM mode pendent, and each may operate as a dual 8-bit PWM timer, — 16-bit PWM mode a 16-bit PWM timer, or as a dual 16-bit capture timer. — Dual 16-bit input capture mode Figure 86 shows the main elements of the VTU. 15 0 15 MODE 0 15 0 15 0 INTCTL IO1CTL 15 0 INTPND IO2CTL Timer Subsystem 2 Timer Subsystem 1 Timer Subsystem 3 7 7 Timer Subsystem 4 7 7 C1 PRSC C2 PRSC C3 PRSC C4RSC == Prescaler Counter == Prescaler Counter == Prescaler Counter == Prescaler Counter 15 0 15 0 15 0 15 0 Count1 Count2 Count3 Count4 Compare - Capture Compare - Capture Compare - Capture Compare - Capture PERCAP1 PERCAP2 PERCAP3 PERCAP4 Compare - Capture Compare - Capture Compare - Capture Compare - Capture DTYCAP1 DTYCAP2 DTYCAP3 DTYCAP4 I/O Control TIO1 I/O Control TIO2 I/O Control TIO3 I/O Control I/O Control TIO5 TIO4 I/O Control TIO6 I/O Control TIO7 I/O Control TIO8 DS088 Figure 86. Versatile Timer Unit Block Diagram 179 www.national.com CP3CN23 25.0 Versatile Timer Unit (VTU) CP3CN23 25.1.1 Dual 8-bit PWM Mode The period of the PWM output waveform is determined by Each timer subsystem may be configured to generate two the value of the PERCAPx register. The TIOx output starts fully independent PWM waveforms on the respective TIOx at the default value as programmed in the IOxCTL.PxPOL pins. In this mode, the counter COUNTx is split and oper- bit. Once the counter value reaches the value of the period ates as two independent 8-bit counters. Each counter incre- register PERCAPx, the counter is cleared on the next counter increment. On the following increment from 00h to ments at the rate determined by the clock prescaler. 01h, the TIOx output will change to the opposite of the deEach of the two 8-bit counters may be started and stopped fault value. separately using the corresponding TxRUN bits. Once either of the two 8-bit timers is running, the clock prescaler The duty cycle of the PWM output waveform is controlled by starts counting. Once the clock prescaler counter value the DTYCAPx register value. Once the counter value reachmatches the value of the associated CxPRSC register field, es the value of the duty cycle register DTYCAPx, the PWM output TIOx changes back to its default value on the next COUNTx is incremented. counter increment. Figure 87 illustrates this concept. COUNTx 0A PERCAPx 0A 09 09 08 08 07 07 06 06 05 05 04 DTYCAPx 04 03 03 02 02 01 01 00 00 TxRUN = 1 TIOx (PxPOL = 0) TIOx (PxPOL = 1) DS089 Figure 87. VTU PWM Generation Reading the PERCAPx or DTYCAPx register will always return the most recent value written to it. The period time is determined by the following formula: PWM Period = (PERCAPx + 1) × (CxPRSC + 1) × TCLK The duty cycle in percent is calculated as follows: Duty Cycle = (DTYCAPx / (PERCAPx + 1)) × 100 If the duty cycle register (DTYCAPx) holds a value which is greater than the value held in the period register (PERCAPx) the TIOx output will remain at the opposite of its default value which corresponds to a duty cycle of 100%. If the duty cycle register (DTYCAPx) register holds a value of 00h, the TIOx output will remain at the default value which corresponds to a duty cycle of 0%, in which case the value in the PERCAPx register is irrelevant. This scheme allows the duty cycle to be programmed in a range from 0% to 100%. The counter registers can be written if both 8-bit counters are stopped. This allows software to preset the counters before starting, which can be used to generate PWM output waveforms with a phase shift relative to each other. If the counter is written with a value other than 00h, it will start incrementing from that value. The TIOx output will remain at its default value until the first 00h to 01h transition of the counter value occurs. If the counter is preset to values which are less than or equal to the value held in the period register (PERCAPx) the counter will count up until a match between the counter value and the PERCAPx register value occurs. The counter will then be cleared and continue counting up. Alternatively, the counter may be written with a value which is greater than the value held in the period register. In that case the counter will count up to FFh, then roll over to 00h. In any case, the TIOx pin always changes its state at the 00h to 01h transition of the counter. In order to allow fully synchronized updates of the period and duty cycle compare values, the PERCAPx and DTYCAPx registers are double buffered when operating in PWM mode. Therefore, if software writes to either the period or duty cycle register while either of the two PWM channels is enabled, the new value will not take effect until the counter Software may only write to the COUNTx register if both value matches the previous period value or the timer is TxRUN bits of a timer subsystem are clear. Any writes to the counter register while either timer is running will be ignored. stopped. www.national.com 180 Figure 89 illustrates the configuration of a timer subsystem while operating in 16-bit PWM mode. The numbering in Figure 89 refers to timer subsystem 1 but equally applies to the other three timer subsystems. The associated TIOx pin will return to its default value as defined by the IOxCTL.PxPOL bit. The counter will stop and will retain its last value. Any pending updates of the PERCAPx and DTYCAPx register will be completed. The prescaler counter will be stopped and reset if both MODE.TxRUN bits are cleared. 7 T1RUN 15 0 [15:0] Restart Count1[15:0] Compare 0 C1PRSC PERCAP1[15:0] TMOD1 = 01 == Prescaler Counter Compare DTYCAP1[15:0] T2RUN T1RUN R Q R S 15 0 7 COUNT1[15:8] Q S 0 [15:8] Res TMOD1 = 10 == Prescaler Counter Figure 88 illustrates the configuration of a timer subsystem while operating in dual 8-bit PWM mode. The numbering in Figure 88 refers to timer subsystem 1 but equally applies to the other three timer subsystems. 7 0 C1PRSC [7:0] Res P2POL COUNT1[7:0] P1POL TIO2 Compare Compare PERCAP1[15:8] PERCAP1[7:0] Compare Compare DTYCAP1[15:8] DTYCAP1[7:0] TIO1 DS091 Figure 89. VTU 16-bit PWM Mode R Q R S 25.1.3 In addition to the two PWM modes, each timer subsystem may be configured to operate in an input capture mode which provides two 16-bit capture channels. The input capture mode can be used to precisely measure the period and duty cycle of external signals. Q S P2POL In capture mode the counter COUNTx operates as a 16-bit up-counter while the two TIOx pins associated with a timer subsystem operate as capture inputs. A capture event on the TIOx pins causes the contents of the counter register (COUNTx) to be copied to the PERCAPx or DTYCAPx registers respectively. P1POL TIO2 TIO1 DS090 Figure 88. VTU Dual 8-Bit PWM Mode 25.1.2 Dual 16-Bit Capture Mode 16-Bit PWM Mode Each of the four timer subsystems may be independently configured to provide a single 16-bit PWM channel. In this case the lower and upper bytes of the counter are concatenated to form a single 16-bit counter. Starting the counter is identical to the 16-bit PWM mode, i.e. setting the lower of the two MODE.TxRUN bits will start the counter and the clock prescaler. In addition, the capture event inputs are enabled once the MODE.TxRUN bit is set. Operation in 16-bit PWM mode is conceptually identical to the dual 8-bit PWM operation as outlined under Dual 8-bit PWM Mode on page 180. The 16-bit timer may be started or stopped with the lower MODE.TxRUN bit, i.e. T1RUN for timer subsystem 1. The TIOx capture inputs can be independently configured to detect a capture event on either a positive transition, a negative transition or both a positive and a negative transition. In addition, any capture event may be used to reset the counter COUNTx and the clock prescaler counter. This avoids the need for software to keep track of timer overflow conditions and greatly simplifies the direct frequency and duty cycle measurement of an external signal. The two TIOx outputs associated with a timer subsystem can be used to produce either two identical PWM waveforms or two PWM waveforms of opposite polarities. This can be accomplished by setting the two PxPOL bits of the respective timer subsystem to either identical or opposite values. 181 www.national.com CP3CN23 The two I/O pins associated with a timer subsystem function as independent PWM outputs in the dual 8-bit PWM mode. If a PWM timer is stopped using its associated MODE.TxRUN bit the following actions result: CP3CN23 Figure 90 illustrates the configuration of a timer subsystem while operating in capture mode. The numbering in Figure 90 refers to timer subsystem 1 but equally applies to the other three timer subsystems. 7 terrupt pending bits are denoted IxAPD through IxDPD where “x” relates to the specific timer subsystem. There is one system level interrupt request for each of the four timer subsystems. Figure 91 illustrates the interrupt structure of the versatile timer module. 0 C1PRSC TMOD1=11 == Prescaler Counter I1AEN I1BEN I1CEN T1RUN I1DEN 15 0 I1APD 15:0 Count1[15:0] Restart System Interrupt Request 1 I1BPD Compare I1CPD PERCAP1[15:0] I1DPD Compare DTYCAP1[15:0] I4AEN I4BEN cap cap rst I4CEN rst I4DEN 2 0 2 C1EDG 0 C2EDG I4APD TIO1 TIO2 DS092 Figure 90. System Interrupt Request 4 I4BPD I4CPD VTU Dual 16-bit Capture Mode I4DPD DS093 25.1.4 Low Power Mode In case a timer subsystem is not used, software can place it in a low-power mode. All clocks to a timer subsystem are stopped and the counter and prescaler contents are frozen once low-power mode is entered. Software may continue to write to the MODE, INTCTL, IOxCTL, and CLKxPS registers. Write operations to the INTPND register are allowed; but if a timer subsystem is in low-power mode, its associated interrupt pending bits cannot be cleared. Software cannot write to the COUNTx, PERCAPx, and DTYCAPx registers of a timer subsystem while it is in low-power mode. All registers can be read at any time. 25.1.5 Interrupts The VTU has a total of 16 interrupt sources, four for each of the four timer subsystems. All interrupt sources have a pending bit and an enable bit associated with them. All in- Figure 91. VTU Interrupt Request Structure Each of the timer pending bits - IxAPD through IxDPD - is set by a specific hardware event depending on the mode of operation, i.e., PWM or Capture mode. Table 70 outlines the specific hardware events relative to the operation mode which cause an interrupt pending bit to be set. 25.1.6 ISE Mode operation The VTU supports breakpoint operation of the In-SystemEmulator (ISE). If FREEZE is asserted, all timer counter clocks will be inhibited and the current value of the timer registers will be frozen; in capture mode, all further capture events are disabled. Once FREEZE becomes inactive, counting will resume from the previous value and the capture input events are re-enabled. Table 70 VTU Interrupt Sources Pending Flag Dual 8-bit PWM Mode 16-bit PWM Mode Capture Mode IxAPD Low Byte Duty Cycle match Duty Cycle match Capture to PERCAPx IxBPD Low Byte Period match Period match Capture to DTYCAPx IxCPD High Byte Duty Cycle match N/A Counter Overflow IxDPD High Byte Period match N/A N/A www.national.com 182 VTU REGISTERS 25.2.1 Mode Control Register (MODE) The VTU contains a total of 19 user accessible registers, as The MODE register is a word-wide read/write register which listed in Table 71. All registers are word-wide and are initial- controls the mode selection of all four timer subsystems. ized to a known value upon reset. All software accesses to The register is clear after reset. the VTU registers must be word accesses. 7 Table 71 VTU Registers 6 5 4 3 2 1 0 TMOD2 T4RUN T3RUN TMOD1 T2RUN T1RUN Name Address Description MODE FF FF80h Mode Control Register IO1CTL FF FF82h I/O Control Register 1 IO2CTL FF FF84h I/O Control Register 2 INTCTL FF FF86h Interrupt Control Register INTPND FF FF88h Interrupt Pending Register CLK1PS FF FF8Ah Clock Prescaler Register 1 CLK2PS FF FF98h Clock Prescaler Register 2 COUNT1 FF FF8Ch Counter 1 Register PERCAP1 FF FF8Eh Period/Capture 1 Register DTYCAP1 FF FF90h Duty Cycle/Capture 1 Register COUNT2 FF FF92h Counter 2 Register PERCAP2 FF FF94h Period/Capture 2 Register DTYCAP2 FF FF96h Duty Cycle/Capture 2 Register COUNT3 FF FF9Ah Counter 3 Register PERCAP3 FF FF9Ch Period/Capture 3 Register DTYCAP3 FF FF9Eh Duty Cycle/Capture 3 Register COUNT4 FF FFA0h Counter 4 Register PERCAP4 FF FFA2h Period/Capture 4 Register DTYCAP4 FF FFA4h Duty Cycle/Capture 4 Register 15 14 13 12 11 10 9 8 TMOD4 T8RUN T7RUN TMOD3 T6RUN T5RUN TxRUN TMODx 183 The Timer Run bit controls whether the corresponding timer is stopped or running. If set, the associated counter and clock prescaler is started depending on the mode of operation. Once set, the clock to the clock prescaler and the counter are enabled and the counter will increment each time the clock prescaler counter value matches the value defined in the associated clock prescaler field (CxPRSC). 0 – Timer stopped. 1 – Timer running. The Timer System Operating Mode field enables or disables the Timer Subsystem and defines its operating mode. 00 – Low-Power Mode. All clocks to the counter subsystem are stopped. The counter is stopped regardless of the value of the TxRUN bits. Read operations to the Timer Subsystem will return the last value; software must not perform any write operations to the Timer Subsystem while it is disabled since those will be ignored. 01 – Dual 8-bit PWM mode. Each 8-bit counter may individually be started or stopped via its associated TxRUN bit. The TIOx pins will function as PWM outputs. 10 – 16-bit PWM mode. The two 8-bit counters are concatenated to form a single 16-bit counter. The counter may be started or stopped with the lower of the two TxRUN bits, i.e. T1RUN, T3RUN, T5RUN, and T7RUN. The TIOx pins will function as PWM outputs. 11 – Capture Mode. Both 8-bit counters are concatenated and operate as a single 16-bit counter. The counter may be started or stopped with the lower of the two TxRUN bits, i.e., T1RUN, T3RUN, T5RUN, and T7RUN. The TIOx pins will function as capture inputs. www.national.com CP3CN23 25.2 CP3CN23 25.2.2 I/O Control Register 1 (IO1CTL) 25.2.3 The I/O Control Register 1 (IO1CTL) is a word-wide read/ write register. The register controls the function of the I/O pins TIO1 through TIO4 depending on the selected mode of operation. The register is clear after reset. 7 6 P2POL 15 P4POL CxEDG 4 3 C2EDG 14 P1POL 12 C4EDG 2 11 P3POL The IO2CTL register is a word-wide read/write register. The register controls the functionality of the I/O pins TIO5 through TIO8 depending on the selected mode of operation. The register is cleared at reset. 0 C1EDG 10 I/O Control Register 2 (IO2CTL) 7 6 P6POL 8 15 C3EDG 4 C6EDG 14 P8POL 3 2 P5POL 12 C8EDG 11 0 C5EDG 10 P7POL 8 C7EDG The Capture Edge Control field specifies the The functionality of the bit fields of the IO2CTL register is polarity of a capture event and the reset of the identical to the ones described in the IO1CTL register seccounter. The value of this three bit field has no tion. effect while operating in PWM mode. 25.2.4 Interrupt Control Register (INTCTL) CxEDG Capture Counter Reset The INTCTL register is a word-wide read/write register. It 000 Rising edge No 001 Falling edge No 010 Rising edge Yes 011 Falling edge Yes 100 Both edges No 101 Both edges Rising edge 110 Both edges Falling edge 111 Both edges Both edges contains the interrupt enable bits for all 16 interrupt sources of the VTU. Each interrupt enable bit corresponds to an interrupt pending bit located in the Interrupt Pending Register (INTPND). All INTCTL register bits are solely under software control. The register is clear after reset. 7 6 5 4 3 2 1 0 I2DEN I2CEN I2BEN I2AEN I1DEN I1CEN I1BEN I1AEN PxPOL 15 The PWM Polarity bit selects the output polarity. While operating in PWM mode the bit specifies the polarity of the corresponding IxAEN PWM output (TIOx). Once a counter is stopped, the output will assume the value of PxPOL, i.e., its initial value. The PxPOL bit has no effect while operating in capture mode. 0 – The PWM output goes high at the 00h to 01h transition of the counter and will go low once the counter value matches the duty cycle value. 1 – The PWM output goes low at the 00h to IxBEN 01h transition of the counter and will go high once the counter value matches the duty cycle value. www.national.com 14 13 12 11 10 9 8 I4DEN I4CEN I4BEN I4AEN I3DEN I3CEN I3BEN I3AEN 184 The Timer x Interrupt A Enable bit controls interrupt requests triggered on the corresponding IxAPD bit being set. The associated IxAPD bit will be updated regardless of the value of the IxAEN bit. 0 – Disable system interrupt request for the IxAPD pending bit. 1 – Enable system interrupt request for the IxAPD pending bit. The Timer x Interrupt B Enable bit controls interrupt requests triggered on the corresponding IxBPD bit being set. The associated IxBPD bit will be updated regardless of the value of the IxBEN bit. 0 – Disable system interrupt request for the IxBPD pending bit. 1 – Enable system interrupt request for the IxBPD pending bit. The Timer x Interrupt C Enable bit controls interrupt requests triggered on the corresponding IxCPD bit being set. The associated IxCPD bit will be updated regardless of the value of the IxCEN bit. 0 – Disable system interrupt request for the IxCPD pending bit. 1 – Enable system interrupt request for the IxCPD pending bit. Timer x Interrupt D Enable bit controls interrupt requests triggered on the corresponding IxDPD bit being set. The associated IxDPD bit will be updated regardless of the value of the IxDEN bit. 0 – Disable system interrupt request for the IxDPD pending bit. 1 – Enable system interrupt request for the IxDPD pending bit. IxDEN 25.2.5 IxDPD 25.2.6 The CLK1PS register is a word-wide read/write register. The register is split into two 8-bit fields called C1PRSC and C2PRSC. Each field holds the 8-bit clock prescaler compare value for timer subsystems 1 and 2 respectively. The register is cleared at reset. 15 C1PRSC 6 5 4 3 2 1 0 I2DPD I2CPD I2BPD I2APD I1DPD I1CPD I1BPD I1APD 14 13 12 11 10 9 8 I4DPD I4CPD I4BPD I4APD I3DPD I3CPD I3BPD I3APD IxAPD IxBPD IxCPD 8 7 C2PRSC C2PRSC 15 Clock Prescaler Register 1 (CLK1PS) 0 C1PRSC Interrupt Pending Register (INTPND) The INTPND register is a word-wide read/write register which contains all 16 interrupt pending bits. There are four interrupt pending bits called IxAPD through IxDPD for each timer subsystem. Each interrupt pending bit is set by a hardware event and can be cleared if software writes a 1 to the bit position. The value will remain unchanged if a 0 is written to the bit position. All interrupt pending bits are cleared (0) upon reset. 7 The Timer x Interrupt D Pending bit indicates that an interrupt condition for the related timer subsystem has occurred. Table 70 on page 182 lists the hardware condition which causes this bit to be set. 0 – No interrupt pending. 1 – Timer interrupt condition occurred. The Timer x Interrupt A Pending bit indicates that an interrupt condition for the related timer subsystem has occurred. Table 70 on page 182 lists the hardware condition which causes this bit to be set. 0 – No interrupt pending. 1 – Timer interrupt condition occurred. The Timer x Interrupt B Pending bit indicates that an interrupt condition for the related timer subsystem has occurred. Table 70 on page 182 lists the hardware condition which causes this bit to be set. 0 – No interrupt pending. 1 – Timer interrupt condition occurred. The Timer x Interrupt C Pending bit indicates that an interrupt condition for the related timer subsystem has occurred. Table 70 on page 182 lists the hardware condition which causes this bit to be set. 0 – No interrupt pending. 1 – Timer interrupt condition occurred. 25.2.7 The Clock Prescaler 1 Compare Value field holds the 8-bit prescaler value for timer subsystem 1. The counter of timer subsystem is incremented each time when the clock prescaler compare value matches the value of the clock prescaler counter. The division ratio is equal to (C1PRSC + 1). For example, 00h is a ratio of 1, and FFh is a ratio of 256. The Clock Prescaler 2 Compare Value field holds the 8-bit prescaler value for timer subsystem 2. The counter of timer subsystem is incremented each time when the clock prescaler compare value matches the value of the clock prescaler counter. The division ratio is equal to (C2PRSC + 1). Clock Prescaler Register 2 (CLK2PS) The Clock Prescaler Register 2 (CLK2PS) is a word-wide read/write register. The register is split into two 8-bit fields called C3PRSC and C4PRSC. Each field holds the 8-bit clock prescaler compare value for timer subsystems 3 and 4 respectively. The register is cleared at reset. 15 8 C4PRSC C3PRSC C4PRSC 185 7 0 C3PRSC The Clock Prescaler 3 Compare Value field holds the 8-bit prescaler value for timer subsystem 3. The counter of timer subsystem is incremented each time when the clock prescaler compare value matches the value of the clock prescaler counter. The division ratio is equal to (C3PRSC + 1). The Clock Prescaler 4 Compare Value field holds the 8-bit prescaler value for timer subsystem 4. The counter of timer subsystem is incremented each time when the clock prescaler compare value matches the value of the clock prescaler counter. The division ratio is equal to (C4PRSC + 1). www.national.com CP3CN23 IxCEN CP3CN23 25.2.8 Counter Register n (COUNTx) 25.2.10 Duty Cycle/Capture Register n (DTYCAPx) The Counter (COUNTx) registers are word-wide read/write registers. There are a total of four registers called COUNT1 through COUNT4, one for each of the four timer subsystems. Software may read the registers at any time. Reading the register will return the current value of the counter. The register may only be written if the counter is stopped (i.e. if both TxRUN bits associated with a timer subsystem are clear). The registers are cleared at reset. 15 0 CNTx 25.2.9 The Duty Cycle/Capture (DTYCAPx) registers are wordwide read/write registers. There are a total of four registers called DTYCAP1 through DTYCAP4, one for each timer subsystem. The registers hold the period compare value in PWM mode or the counter value at the time the last associated capture event occurred. In PWM mode, the register is double buffered. If a new duty cycle compare value is written while the counter is running, the write will not take effect until the counter value matches the previous period compare value or until the counter is stopped. The update takes effect on period boundaries only. Reading may take place at any time and will return the most recent value which was written. The DTYCAPx registers are cleared at reset. Period/Capture Register n (PERCAPx) The PERCAPx registers are word-wide read/write registers. There are a total of four registers called PERCAP1 through PERCAP4, one for each timer subsystem. The registers hold the period compare value in PWM mode of the counter value at the time the last associated capture event occurred. In PWM mode the register is double buffered. If a new period compare value is written while the counter is running, the write will not take effect until counter value matches the previous period compare value or until the counter is stopped. Reading may take place at any time and will return the most recent value which was written. The PERCAPx registers are cleared at reset. 15 0 PCAPx www.national.com 186 15 0 DCAPx Table 72 is a detailed memory map showing the specific memory address of the memory, I/O ports, and registers. The table shows the starting address, the size, and a brief description of each memory block and register. For detailed information on using these memory locations, see the applicable sections in the data sheet. All addresses not listed in the table are reserved and must not be read or written. An attempt to access an unlisted address will have unpredictable results. the byte-wide and word-wide registers reside at word boundaries (even addresses). Therefore, each byte-wide register uses only the lowest eight bits of the internal data bus. Most device registers are read/write registers. However, some registers are read-only or write-only, as indicated in the table. An attempt to read a write-only register or to write a read-only register will have unpredictable results. When software writes to a register in which one or more bits Each byte-wide register occupies a single address and can are reserved, it must write a zero to each reserved bit unless be accessed only in a byte-wide transaction. Each word- indicated otherwise in the description of the register. Readwide register occupies two consecutive memory addresses ing a reserved bit returns an undefined value. and can be accessed only in a word-wide transaction. Both Table 72 Detailed Device Mapping Register Name Size Address Access Type Value After Reset Comments CAN0 Module Message Buffers CMB0_CNSTAT Word 0E F000h Read/Write XXXXh CMB0_TSTP Word 0E F002h Read/Write XXXXh CMB0_DATA3 Word 0E F004h Read/Write XXXXh CMB0_DATA2 Word 0E F006h Read/Write XXXXh CMB0_DATA1 Word 0E F008h Read/Write XXXXh CMB0_DATA0 Word 0E F00Ah Read/Write XXXXh CMB0_ID0 Word 0E F00Ch Read/Write XXXXh CMB0_ID1 Word 0E F00Eh Read/Write XXXXh CMB1 8-word 0E F010h– 0E F01Fh Read/Write XXXXh Same register layout as CMB0. CMB2 8-word 0E F020h– 0E F02Fh Read/Write XXXXh Same register layout as CMB0. CMB3 8-word 0E F030h– 0E F03Fh Read/Write XXXXh Same register layout as CMB0. CMB4 8-word 0E F040h– 0E F04Fh Read/Write XXXXh Same register layout as CMB0. CMB5 8-word 0E F050h– 0E F05Fh Read/Write XXXXh Same register layout as CMB0. CMB6 8-word 0E F060h– 0E F06Fh Read/Write XXXXh Same register layout as CMB0. CMB7 8-word 0E F070h– 0E F07Fh Read/Write XXXXh Same register layout as CMB0. CMB8 8-word 0E F080h– 0E F08Fh Read/Write XXXXh Same register layout as CMB0. CMB9 8-word 0E F090h– 0E F09Fh Read/Write XXXXh Same register layout as CMB0. 187 www.national.com CP3CN23 26.0 Register Map CP3CN23 Size Address Access Type Value After Reset Comments CMB10 8-word 0E F0A0h– 0E F0AFh Read/Write XXXXh Same register layout as CMB0. CMB11 8-word 0E F0B0h– 0E F0BFh Read/Write XXXXh Same register layout as CMB0. CMB12 8-word 0E F0C0h– 0E F0CFh Read/Write XXXXh Same register layout as CMB0. CMB13 8-word 0E F0D0h– 0E F0DFh Read/Write XXXXh Same register layout as CMB0. CMB14 8-word 0E F0E0h– 0E F0EFh Read/Write XXXXh Same register layout as CMB0. Register Name CAN0 Registers CGCR0 Word 0E F100h Read/Write 0000h CTIM0 Word 0E F102h Read/Write 0000h GMSKX0 Word 0E F104h Read/Write 0000h GMSKB0 Word 0E F106h Read/Write 0000h BMSKX0 Word 0E F108h Read/Write 0000h BMSKB0 Word 0E F10Ah Read/Write 0000h CIEN0 Word 0E F10Ch Read/Write 0000h CIPND0 Word 0E F10Eh Read Only 0000h CICLR0 Word 0E F110h Write Only 0000h CICEN0 Word 0E F112h Read/Write 0000h CSTPND0 Word 0E F114h Read Only 0000h CANEC0 Word 0E F116h Read Only 0000h CEDIAG0 Word 0E F118h Read Only 0000h CTMR0 Word 0E F11Ah Read Only 0000h www.national.com 188 Size Address Access Type Value After Reset Comments CAN1 Module Message Buffers CMB0_CNSTAT Word 0E F200h Read/Write XXXXh CMB0_TSTP Word 0E F202h Read/Write XXXXh CMB0_DATA3 Word 0E F204h Read/Write XXXXh CMB0_DATA2 Word 0E F206h Read/Write XXXXh CMB0_DATA1 Word 0E F208h Read/Write XXXXh CMB0_DATA0 Word 0E F20Ah Read/Write XXXXh CMB0_ID0 Word 0E F20Ch Read/Write XXXXh CMB0_ID1 Word 0E F20Eh Read/Write XXXXh CMB1 8-word 0E F210h– 0E F21Fh Read/Write XXXXh Same register layout as CMB0. CMB2 8-word 0E F220h– 0E F22Fh Read/Write XXXXh Same register layout as CMB0. CMB3 8-word 0E F230h– 0E F23Fh Read/Write XXXXh Same register layout as CMB0. CMB4 8-word 0E F240h– 0E F24Fh Read/Write XXXXh Same register layout as CMB0. CMB5 8-word 0E F250h– 0E F25Fh Read/Write XXXXh Same register layout as CMB0. CMB6 8-word 0E F260h– 0E F26Fh Read/Write XXXXh Same register layout as CMB0. CMB7 8-word 0E F270h– 0E F27Fh Read/Write XXXXh Same register layout as CMB0. CMB8 8-word 0E F280h– 0E F28Fh Read/Write XXXXh Same register layout as CMB0. CMB9 8-word 0E F290h– 0E F29Fh Read/Write XXXXh Same register layout as CMB0. CMB10 8-word 0E F2A0h– 0E F2AFh Read/Write XXXXh Same register layout as CMB0. CMB11 8-word 0E F2B0h– 0E F2BFh Read/Write XXXXh Same register layout as CMB0. CMB12 8-word 0E F2C0h– 0E F2CFh Read/Write XXXXh Same register layout as CMB0. CMB13 8-word 0E F2D0h– 0E F2DFh Read/Write XXXXh Same register layout as CMB0. CMB14 8-word 0E F2E0h– 0E F2EFh Read/Write XXXXh Same register layout as CMB0. 189 www.national.com CP3CN23 Register Name CP3CN23 Register Name Size Address Access Type Value After Reset CAN1 Registers CGCR1 Word 0E F300h Read/Write 0000h CTIM1 Word 0E F302h Read/Write 0000h GMSKX1 Word 0E F304h Read/Write 0000h GMSKB1 Word 0E F306h Read/Write 0000h BMSKX1 Word 0E F308h Read/Write 0000h BMSKB1 Word 0E F30Ah Read/Write 0000h CIEN1 Word 0E F30Ch Read/Write 0000h CIPND1 Word 0E F30Eh Read Only 0000h CICLR1 Word 0E F310h Write Only 0000h CICEN1 Word 0E F312h Read/Write 0000h CSTPND1 Word 0E F314h Read Only 0000h CANEC1 Word 0E F316h Read Only 0000h CEDIAG1 Word 0E F318h Read Only 0000h CTMR1 Word 0E F31Ah Read Only 0000h DMA Controller ADCA0 Double Word FF F800h Read/Write 0000 0000h ADRA0 Double Word FF F804h Read/Write 0000 0000h ADCB0 Double Word FF F808h Read/Write 0000 0000h ADRB0 Double Word FF F80Ch Read/Write 0000 0000h BLTC0 Word FF F810h Read/Write 0000h BLTR0 Word FF F814h Read/Write 0000h DMACNTL0 Word FF F81Ch Read/Write 0000h DMASTAT0 Byte FF F81Eh Read/Write 00h ADCA1 Double Word FF F820h Read/Write 0000 0000h ADRA1 Double Word FF F824h Read/Write 0000 0000h ADCB1 Double Word FF F828h Read/Write 0000 0000h ADRB1 Double Word FF F82Ch Read/Write 0000 0000h www.national.com 190 Comments Address Access Type Value After Reset BLTC1 Word FF F830h Read/Write 0000h BLTR1 Word FF F834h Read/Write 0000h DMACNTL1 Word FF F83Ch Read/Write 0000h DMASTAT1 Byte FF F83Eh Read/Write 00h ADCA2 Double Word FF F840h Read/Write 0000 0000h ADRA2 Double Word FF F844h Read/Write 0000 0000h ADCB2 Double Word FF F848h Read/Write 0000 0000h ADRB2 Double Word FF F84Ch Read/Write 0000 0000h BLTC2 Word FF F850h Read/Write 0000h BLTR2 Word FF F854h Read/Write 0000h DMACNTL2 Word FF F85Ch Read/Write 0000h DMASTAT2 Byte FF F85Eh Read/Write 00h ADCA3 Double Word FF F860h Read/Write 0000 0000h ADRA3 Double Word FF F864h Read/Write 0000 0000h ADCB3 Double Word FF F868h Read/Write 0000 0000h ADRB3 Double Word FF F86Ch Read/Write 0000 0000h BLTC3 Word FF F870h Read/Write 0000h BLTR3 Word FF F874h Read/Write 0000h DMACNTL3 Word FF F87Ch Read/Write 0000h DMASTAT3 Byte FF F87Eh Read/Write 00h Comments Bus Interface Unit BCFG Byte FF F900h Read/Write 07h IOCFG Word FF F902h Read/Write 069Fh SZCFG0 Word FF F904h Read/Write 069Fh SZCFG1 Word FF F906h Read/Write 069Fh SZCFG2 Word FF F908h Read/Write 069Fh 191 www.national.com CP3CN23 Size Register Name CP3CN23 Register Name Size Address Access Type Value After Reset System Configuration MCFG Byte FF F910h Read/Write 00h DBGCFG Byte FF F912h Read/Write 00h MSTAT Byte FF F914h Read Only ENV2:0 pins SWRESET Byte FF F918h Write Only N/A Flash Program Memory Interface FMIBAR Word FF F940h Read/Write 0000h FMIBDR Word FF F942h Read/Write 0000h FM0WER Word FF F944h Read/Write 0000h FM1WER Word FF F946h Read/Write 0000h FMCTRL Word FF F94Ch Read/Write 0000h FMSTAT Word FF F94Eh Read/Write 0000h FMPSR Byte FF F950h Read/Write 04h FMSTART Byte FF F952h Read/Write 18h FMTRAN Byte FF F954h Read/Write 30h FMPROG Byte FF F956h Read/Write 16h FMPERASE Byte FF F958h Read/Write 04h FMMERASE0 Byte FF F95Ah Read/Write EAh FMEND Byte FF F95Eh Read/Write 18h FMMEND Byte FF F960h Read/Write 3Ch FMRCV Byte FF F962h Read/Write 04h FMAR0 Word FF F964h Read Only FMAR1 Word FF F966h Read Only FMAR2 Word FF F968h Read Only Flash Data Memory Interface FSMIBAR Word FF F740h Read/Write 0000h FSMIBDR Word FF F742h Read/Write 0000h FSM0WER Word FF F744h Read/Write 0000h FSMCTRL Word FF F74Ch Read/Write 0000h FSMSTAT Word FF F74Eh Read/Write 0000h FSMPSR Byte FF F750h Read/Write 04h FSMSTART Byte FF F752h Read/Write 18h www.national.com 192 Comments Address Access Type Value After Reset FSMTRAN Byte FF F754h Read/Write 30h FSMPROG Byte FF F756h Read/Write 16h FSMPERASE Byte FF F758h Read/Write 04h FSMMERASE0 Byte FF F75Ah Read/Write EAh FSMEND Byte FF F75Eh Read/Write 18h FSMMEND Byte FF F760h Read/Write 3Ch FSMRCV Byte FF F762h Read/Write 04h FSMAR0 Word FF F764h Read Only FSMAR1 Word FF F766h Read Only FSMAR2 Word FF F768h Read Only Comments CVSD/PCM Converter CVSDIN Word FF FC20h Write Only 0000h CVSDOUT Word FF FC22h Read Only 0000h PCMIN Word FF FC24h Write Only 0000h PCMOUT Word FF FC26h Read Only 0000h LOGIN Byte FF FC28h Write Only 0000h LOGOUT Byte FF FC2Ah Read Only 0000h LINEARIN Word FF FC2Ch Write Only 0000h LINEAROUT Word FF FC2Eh Read Only 0000h CVCTRL Word FF FC30h Read/Write 0000h CVSTAT Word FF FC32h Read Only 0000h CVTEST Word FF FC34h Read/Write 0000h CVRADD Word FF FC36h Read/Write 0000h CVRDAT Word FF FC38h Read/Write 0000h CVDECOUT Word FF FC3Ah Read Only 0000h CVENCIN Word FF FC3Ch Read Only 0000h CVENCPR Word FF FC3Eh Read Only 0000h Triple Clock + Reset CRCTRL Byte FF FC40h Read/Write 00X0 0110b PRSFC Byte FF FC42h Read/Write 4Fh PRSSC Byte FF FC44h Read/Write B6h PRSAC Byte FF FC46h Read/Write FFh 193 www.national.com CP3CN23 Size Register Name CP3CN23 Register Name Size Address Access Type Value After Reset Comments Power Management PMMCR Byte FF FC60h Read/Write 00h PMMSR Byte FF FC62h Read/Write 0000 0XXXb Multi-Input Wake-Up 0 WK0EDG Word FF FC80h Read/Write 00h WK0ENA Word FF FC82h Read/Write 00h WK0ICTL1 Word FF FC84h Read/Write 00h WK0ICTL2 Word FF FC86h Read/Write 00h WK0PND Word FF FC88h Read/Write 00h WK0PCL Word FF FC8Ah Write Only XXh WK0IENA Word FF FC8Ch Read/Write 00h Bits may only be set; writing 0 has no effect. Multi-Input Wake-Up 1 WK1EDG Word FF FCA0h Read/Write 00h WK1ENA Word FF FCA2h Read/Write 00h WK1ICTL1 Word FF FCA4h Read/Write 00h WK1ICTL2 Word FF FCA6h Read/Write 00h WK1PND Word FF FCA8h Read/Write 00h WK1PCL Word FF FCAAh Write Only XXh WK1IENA Word FF FCACh Read/Write 00h General-Purpose I/O Ports PBALT Byte FF FB00h Read/Write 00h PBDIR Byte FF FB02h Read/Write 00h PBDIN Byte FF FB04h Read Only XXh PBDOUT Byte FF FB06h Read/Write XXh PBWPU Byte FF FB08h Read/Write 00h PBHDRV Byte FF FB0Ah Read/Write 00h PBALTS Byte FF FB0Ch Read/Write 00h PCALT Byte FF FB10h Read/Write 00h www.national.com 194 Bits may only be set; writing 0 has no effect. Address Access Type Value After Reset PCDIR Byte FF FB12h Read Only 00h PCDIN Byte FF FB14h Read/Write XXh PCDOUT Byte FF FB16h Read/Write XXh PCWPU Byte FF FB18h Read/Write 00h PCHDRV Byte FF FB1Ah Read/Write 00h PCALTS Byte FF FB1Ch Read/Write 00h PEALT Byte FF FCC0h Read/Write 00h PEDIR Byte FF FCC2h Read/Write 00h PEDIN Byte FF FCC4h Read Only XXh PEDOUT Byte FF FCC6h Read/Write XXh PEWPU Byte FF FCC8h Read/Write 00h PEHDRV Byte FF FCCAh Read/Write 00h PEALTS Byte FF FCCCh Read/Write 00h PFALT Byte FF FCE0h Read/Write 00h PFDIR Byte FF FCE2h Read/Write 00h PFDIN Byte FF FCE4h Read Only XXh PFDOUT Byte FF FCE6h Read/Write XXh PFWPU Byte FF FCE8h Read/Write 00h PFHDRV Byte FF FCEAh Read/Write 00h PFALTS Byte FF FCECh Read/Write 00h PGALT Byte FF F300h Read/Write 00h PGDIR Byte FF F302h Read/Write 00h PGDIN Byte FF F304h Read Only XXh PGDOUT Byte FF F306h Read/Write XXh PGWPU Byte FF F308h Read/Write 00h PGHDRV Byte FF F30Ah Read/Write 00h PGALTS Byte FF F30Ch Read/Write 00h PHALT Byte FF F320h Read/Write 00h PHDIR Byte FF F322h Read/Write 00h PHDIN Byte FF F324h Read Only XXh PHDOUT Byte FF F326h Read/Write XXh PHWPU Byte FF F328h Read/Write 00h PHHDRV Byte FF F32Ah Read/Write 00h PHALTS Byte FF F32Ch Read/Write 00h PJALT Byte FF F340h Read/Write 00h PJDIR Byte FF F342h Read/Write 00h 195 Comments www.national.com CP3CN23 Size Register Name CP3CN23 Size Address Access Type Value After Reset PJDIN Byte FF F344h Read Only XXh PJDOUT Byte FF F346h Read/Write XXh PJWPU Byte FF F348h Read/Write 00h PJHDRV Byte FF F34Ah Read/Write 00h PJALTS Byte FF F34Ch Read/Write 00h Register Name Comments Advanced Audio Interface ARFR Word FF FD40h Read Only 0000h ARDR0 Word FF FD42h Read Only 0000h ARDR1 Word FF FD44h Read Only 0000h ARDR2 Word FF FD46h Read Only 0000h ARDR3 Word FF FD48h Read Only 0000h ATFR Word FF FD4Ah Write Only XXXXh ATDR0 Word FF FD4Ch Write Only 0000h ATDR1 Word FF FD4Eh Write Only 0000h ATDR2 Word FF FD50h Write Only 0000h ATDR3 Word FF FD52h Write Only 0000h AGCR Word FF FD54h Read/Write 0000h AISCR Word FF FD56h Read/Write 0000h ARSCR Word FF FD58h Read/Write 0004h ATSCR Word FF FD5Ah Read/Write F003h ACCR Word FF FD5Ch Read/Write 0000h ADMACR Word FF FD5Eh Read/Write 0000h Interrupt Control Unit IVCT Byte FF FE00h Read Only 10h NMISTAT Byte FF FE02h Read Only 00h EXNMI Byte FF FE04h Read/Write XXXX 00X0b ISTAT0 Word FF FE0Ah Read Only 0000h ISTAT1 Word FF FE0Ch Read Only 0000h ISTAT2 Word FF FE20h Read Only 0000h IENAM0 Word FF FE0Eh Read/Write FFFFh IENAM1 Word FF FE10h Read/Write FFFFh IENAM2 Word FF FE22h Read/Write FFFFh www.national.com 196 Fixed Addr. Size Address Access Type Value After Reset Comments Microwire/SPI Interface MWDAT Word FF F3A0h Read/Write XXXXh MWCTL1 Word FF F3A2h Read/Write 0000h MWSTAT Word FF F3A4h Read Only All implemented bits are 0 UART0 U0TBUF Byte FF F200h Read/Write XXh U0RBUF Byte FF F202h Read Only XXh U0ICTRL Byte FF F204h Read/Write 01h U0STAT Byte FF F206h Read only 00h U0FRS Byte FF F208h Read/Write 00h U0MDSL1 Byte FF F20Ah Read/Write 00h U0BAUD Byte FF F20Ch Read/Write 00h U0PSR Byte FF F20Eh Read/Write 00h U0OVR Byte FF F210h Read/Write 00h U0MDSL2 Byte FF F212h Read/Write 00h U0SPOS Byte FF F214h Read/Write 06h Bits 0:1 read only UART1 U1TBUF Byte FF F220h Read/Write XXh U1RBUF Byte FF F222h Read Only XXh U1ICTRL Byte FF F224h Read/Write 01h U1STAT Byte FF F226h Read only 00h U1FRS Byte FF F228h Read/Write 00h U1MDSL1 Byte FF F22Ah Read/Write 00h U1BAUD Byte FF F22Ch Read/Write 00h U1PSR Byte FF F22Eh Read/Write 00h U1OVR Byte FF F230h Read/Write 00h U1MDSL2 Byte FF F232h Read/Write 00h U1SPOS Byte FF F234h Read/Write 06h 197 Bits 0:1 read only www.national.com CP3CN23 Register Name CP3CN23 Register Name Size Address Access Type Value After Reset Comments UART2 U2TBUF Byte FF F240h Read/Write XXh U2RBUF Byte FF F242h Read Only XXh U2ICTRL Byte FF F244h Read/Write 01h U2STAT Byte FF F246h Read only 00h U2FRS Byte FF F248h Read/Write 00h U2MDSL1 Byte FF F24Ah Read/Write 00h U2BAUD Byte FF F24Ch Read/Write 00h U2PSR Byte FF F24Eh Read/Write 00h U2OVR Byte FF F250h Read/Write 00h U2MDSL2 Byte FF F252h Read/Write 00h U2SPOS Byte FF F254h Read/Write 06h Bits 0:1 read only UART3 U3TBUF Byte FF F260h Read/Write XXh U3RBUF Byte FF F262h Read Only XXh U3ICTRL Byte FF F264h Read/Write 01h U3STAT Byte FF F266h Read only 00h U3FRS Byte FF F268h Read/Write 00h U3MDSL1 Byte FF F26Ah Read/Write 00h U3BAUD Byte FF F26Ch Read/Write 00h U3PSR Byte FF F26Eh Read/Write 00h U3OVR Byte FF F270h Read/Write 00h U3MDSL2 Byte FF F272h Read/Write 00h U3SPOS Byte FF F274h Read/Write 06h www.national.com 198 Bits 0:1 read only Size Address Access Type Value After Reset Comments ACCESS.bus ACBSDA Byte FF F2A0h Read/Write XXh ACBST Byte FF F2A2h Read/Write 00h ACBCST Byte FF F2A4h Read/Write 00h ACBCTL1 Byte FF F2A6h Read/Write 00h ACBADDR Byte FF F2A8h Read/Write XXh ACBCTL2 Byte FF F2AAh Read/Write 00h ACBADDR2 Byte FF F2ACh Read/Write XXh ACBCTL3 Byte FF F2AEh Read/Write 00h Timing and Watchdog TWCFG Byte FF FF20h Read/Write 00h TWCP Byte FF FF22h Read/Write 00h TWMT0 Word FF FF24h Read/Write FFFFh T0CSR Byte FF FF26h Read/Write 00h WDCNT Byte FF FF28h Write Only 0Fh WDSDM Byte FF FF2Ah Write Only 5Fh Multi-Function Timer TCNT1 Word FF FF40h Read/Write XXh TCRA Word FF FF42h Read/Write XXh TCRB Word FF FF44h Read/Write XXh TCNT2 Word FF FF46h Read/Write XXh TPRSC Byte FF FF48h Read/Write 00h TCKC Byte FF FF4Ah Read/Write 00h TCTRL Byte FF FF4Ch Read/Write 00h TICTL Byte FF FF4Eh Read/Write 00h TICLR Byte FF FF50h Read/Write 00h 199 www.national.com CP3CN23 Register Name CP3CN23 Register Name Size Address Access Type Value After Reset Versatile Timer Unit MODE Word FF FF80h Read/Write 0000h IO1CTL Word FF FF82h Read/Write 0000h IO2CTL Word FF FF84h Read/Write 0000h INTCTL Word FF FF86h Read/Write 0000h INTPND Word FF FF88h Read/Write 0000h CLK1PS Word FF FF8Ah Read/Write 0000h COUNT1 Word FF FF8Ch Read/Write 0000h PERCAP1 Word FF FF8Eh Read/Write 0000h DTYCAP1 Word FF FF90h Read/Write 0000h COUNT2 Word FF FF92h Read/Write 0000h PERCAP2 Word FF FF94h Read/Write 0000h DTYCAP2 Word FF FF96h Read/Write 0000h CLK2PS Word FF FF98h Read/Write 0000h COUNT3 Word FF FF9Ah Read/Write 0000h PERCAP3 Word FF FF9Ch Read/Write 0000h DTYCAP3 Word FF FF9Eh Read/Write 0000h COUNT4 Word FF FFA0h Read/Write 0000h PERCAP4 Word FF FFA2h Read/Write 0000h DTYCAP4 Word FF FFA4h Read/Write 0000h ADC ADCGCR Word FF F3C0h Read/Write 0000h ADCACR Word FF F3C2h Read/Write 0000h ADCCNTRL Word FF F3C4h Read/Write 0000h ADCSTART Word FF F3C6h Write Only N/A ADCSCDLY Word FF F3C8h Read/Write 0000h ADCRESLT Word FF F3CAh Read Only 0000h ADCSMBC0 Word FF F3CEh Read/Write 1483h ADCSMBC1 Word FF F3D0h Read/Write 24E6h ADCSMBC2 Word FF F3D2h Read/Write 2508h ADCSMBC3 Word FF F3D4h Read/Write 314Ah ADCSMSH Word FF F3D6h Read/Write 01A2h www.national.com 200 Comments Size Address Access Type Value After Reset Comments RNG RNGCST Word FF F280h Read/Write 0000h RNGD Word FF F282h Read/Write 0000h RNGDIVH Word FF F284h Read/Write 0000h RNGDIVL Word FF F286h Read/Write 0000h 201 www.national.com CP3CN23 Register Name CP3CN23 27.0 Register Bit Fields The following tables show the functions of the bit fields of the device registers. For more information on using these registers, see the detailed description of the applicable function elsewhere in this data sheet. CAN Control/ Status 15 CGCRn 14 13 12 Reserved CTIMn 11 10 EIT 9 8 DIAG INTE LOOP IGN EN RNAL BACK ACK PSC[6:0] GMSKBn 7 6 5 LO DD IR SJW[1:0] TSEG2[2:0] IDE GM[17:15] RTR IDE BM[17:15] BM[14:0] XRTR IEN[14:0] CIPNDn EI PND IPND[14:0] CICLRn EI CLR ICLR[14:0] CICENn EI CEN ICEN[14:0] CSTPNDn Reserved CANECn REC[7:0] Res. NS[2:0] IRQ IST[3:0] TEC[7:0] DRI STU MON CRC TXE VE FF EBID[5:0] CTMRn CTMR[15:0] 202 0 XRTR EI EN www.national.com 1 TST BUFF CAN CRX CTX PEN LOCK EN RTR BM[28:18] BMSKXn CEDIAGn 2 GM[14:0] BMSKBn CIENn 3 TSEG1[3:0] GM[28:18] GMSKXn 4 EFID[3:0] 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0 CMBn.ID1 XI28 XI27 XI26 XI25 XI24 XI23 XI22 XI21 XI20 XI19 XI18 SRR IDE ID10 ID9 ID8 ID7 ID6 ID5 ID4 ID3 ID2 ID1 ID0 RTR XI17 XI16 XI15 CMBn.ID0 XI14 XI13 XI12 XI11 XI10 XI1 CMBn.DATA0 Data Data Data Data Data Data Data Data Data Data Data Data Data Data Data Data 1.7 1.6 1.5 1.4 1.3 1.2 1.1 1.0 2.7 2.6 2.5 2.4 2.3 2.2 2.1 2.0 CMBn.DATA1 Data Data Data Data Data Data Data Data Data Data Data Data Data Data Data Data 3.7 3.6 3.5 3.4 3.3 3.2 3.1 3.0 4.7 4.6 4.5 4.4 4.3 4.2 4.1 4.0 CMBn.DATA2 Data Data Data Data Data Data Data Data Data Data Data Data Data Data Data Data 5.7 5.6 5.5 5.4 5.3 5.2 5.1 5.0 6.7 6.6 6.5 6.4 6.3 6.2 6.1 6.0 CMBn.DATA3 Data Data Data Data Data Data Data Data Data Data Data Data Data Data Data Data 7.7 7.6 7.5 7.4 7.3 7.2 7.1 7.0 8.7 8.6 8.5 8.4 8.3 8.2 8.1 8.0 CMBn.TSTP TSTP TSTP TSTP TSTP TSTP TSTP TSTP TSTP TSTP TSTP TSTP TSTP TSTP TSTP TSTP TSTP 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0 XI9 CMBn.CNTSTAT DLC3 DLC2 DLC1 DLC0 DMAC 20..16 15 Registers 14 13 12 XI8 XI7 XI6 Reserved 11 10 XI5 9 8 7 6 Device A Address Counter ADRA Device A Address ADCB Device B Address Counter ADRB Device B Address BLTC N/A Block Length Counter BLTR N/A Block Length DMACNTL N/A DMASTAT INCB ADB INCA XI3 XI2 PRI3 PRI2 PRI1 PRI0 ST3 ADCA Res. XI4 ADA N/A 203 SW Res. RQ OT 5 4 3 DIR IND TCS Reserved VLD ST2 XI0 RTR ST1 ST0 2 1 0 EO VR ETC CH EN CH OVR AC TC www.national.com CP3CN23 CAN Memory Registers CP3CN23 System Configuration Registers MCFG 7 6 5 4 3 MEM_IO_ MISC_IO_ Reserved SPEED SPEED Reserved DBGCFG 2 SCLKOE 1 MCLKOE PLLCLKOE Reserved MSTAT ISPRST BIU Registers 15 DPGM BUSY WDRST Reserved 12 11 10 9 8 BCFG PGMBUSY 7 6 0 FREEZE ON OENV1 OENV0 OENV2 5 4 EXIOE 3 2 1 Reserved IOCFG Reserved EWR IPST Res. BW Reserved HOLD WAIT SZCFG0 Reserved FRE IPRE IPST Res. BW WBR RBE HOLD WAIT SZCFG1 Reserved FRE IPRE IPST Res. BW WBR RBE HOLD WAIT SZCFG2 Reserved FRE IPRE IPST Res. BW WBR RBE HOLD WAIT TBI Register 7 6 TMODE Flash Program Memory Interface Registers FMIBAR 5 4 Reserved 15 14 13 12 11 3 TSTEN 10 9 8 2 1 ENMEM 7 6 5 Reserved 0 TMSEL 4 3 2 1 0 IBA FMIBDR IBD FM0WER FM0WE FM1WER FM1WE FM2WER FM2WE FM3WER FM3WE FMCTRL 0 Reserved MER PER PE IENP DIS LOW Res. CWD ROG VRF PRW FMSTAT Reserved FM DE FM PERR EERR RR FULL BUSY FMPSR Reserved FTDIV FMSTART Reserved FTSTART FMTRAN Reserved FTTRAN www.national.com 204 15 14 13 12 11 10 9 8 7 6 5 4 3 FMPROG Reserved FTPROG FMPERASE Reserved FTPER FMMERASE0 Reserved FTMER FMEND Reserved FTEND FMMEND Reserved FTMEND FMRCV Reserved FTRCV FMAR0 FMAR1 FSMIBAR RDPROT WRPROT 0 Res. ISPE EMPTY BOOTAREA CADR15:0 15 14 13 12 11 10 9 8 7 6 5 Reserved IBD FSM0WER FM0WE FSM1WER FM1WE FSM2WER FM2WE FSM3WER FM3WE Reserved FSMSTAT MER PER 3 2 1 PE 0 IENP DIS LOW Res. CWD ROG VRF PRW DE FM FM PE RR FULL BUSY RR Reserved FSMPSR 4 IBA FSMIBDR FSMCTRL 1 Reserved FMAR2 Flash Data Memory Interface Registers 2 Reserved FTDIV FSMSTART Reserved FTSTART FSMTRAN Reserved FTTRAN FSMPROG Reserved FTPROG FSMPERASE Reserved FTPER FSMMERASE0 Reserved FTMER FSMEND Reserved FTEND FSMMEND Reserved FTMEND FSMRCV Reserved FTRCV 205 EE RR www.national.com CP3CN23 Flash Program Memory Interface Registers CP3CN23 Flash Data Memory Interface Registers 15 14 13 12 11 10 9 FSMAR0 FSMAR1 8 6 5 4 3 2 RDPROT WRPROT EMPTY BOOTAREA CADR15:0 15 14 13 12 11 10 9 8 7 6 5 4 3 2 PCMIN PCMOUT PCMOUT LOGIN Reserved LOGIN LOGOUT Reserved LOGOUT LINEARIN LINEARIN LINEAROUT LINEAROUT PCM CO NV Reserved CVSTAT CVSD CONV Reserved CVTEST CVS DMA DMA DMA DMA CVS PCM CLK DER PI PO CI CO DINT INT EN RINT CV EN PCM CVN INT F CV NE CVOUTST CVINST Reserved TB CVRDAT CVDECOUT CVDECOUT CVENCIN CVENCIN CVENCPR CVENCPRT 7 6 Reserved Reserved 5 4 3 2 1 0 POR ACE2 ACE1 PLLPWD FCLK SCLK MODE FCDIV PRSSC www.national.com RT CVRADD CVRDAT PRSAC CVF CVE TEST ENC DEC _VAL _IN _EN Reserved CVRADD PRSFC 0 CVSDOUT PCMIN CRCTRL 1 CVSDIN CVSDOUT CLK3RES Registers 0 Res. ISPE CVSDIN CVCTRL 1 Reserved FSMAR2 CVSD/PCM Registers 7 SCDIV ACDIV2 ACDIV1 206 PMMCR 7 6 5 4 3 2 1 0 HCCH HCCM DHC DMC WBPSM HALT IDLE PSM OHC OMC OLC PMMSR Reserved MIWU16 Registers 15 CP3CN23 PMM Register 14 13 12 11 10 9 8 7 WKEDG WKED WKENA WKEN WKINTR6 WKINTR5 WKINTR4 6 WKINTR3 5 4 3 2 1 0 WKICTL1 WKINTR7 WKINTR2 WKINTR1 WKINTR0 WKICTL2 WKINTR15 WKINTR14 WKINTR13 WKINTR12 WKINTR11 WKINTR10 WKINTR9 WKINTR8 WKPND WKPD WKPCL WKCL WKIENA WKIEN GPIO Registers 7 6 5 4 3 2 1 PxALT Px Pins Alternate Function Enable PxDIR Px Port Direction PxDIN Px Port Output Data PxDOUT Px Port Input Data PxWPU Px Port Weak Pull-Up Enable PxHDRV Px Port High Drive Strength Enable PxALTS Px Pins Alternate Function Source Selection AAI Registers 15 14 13 12 11 10 9 8 7 6 5 4 3 ARSR ARSH ARSL ATSR ATSH ATSL ARFR ARFH ARFL ARDR0 ARDH ARDL ARDR1 ARDH ARDL ARDR2 ARDH ARDL ARDR3 ARDH ARDL ATFR ATFH ATFL ATDR0 ATDH ATDL 207 2 0 1 0 www.national.com CP3CN23 AAI Registers 15 14 13 12 11 10 9 8 7 6 5 4 3 ATDR1 ATDH ATDL ATDR2 ATDH ATDL ATDR3 ATDH ATDL AGCR CLK EN AAI IOM2 IFS EN FSL TX EIC CTF CRF IEBC FSS IEFS TX IC RX EIC AISCR Reserved ARSCR RXFWM RXDSA ATSCR TXFWM TXDSA ACCR RX IC TX EIP TX IP Reserved ICU Registers ACO 7 6 Reserved 0 0 LPB DWL ASS TX EIE TX IE RX IE RXSA RXO RXE RXF RX AF TXSA TXU TXF TXE TXAE 5 4 RMD 3 2 1 0 INTVECT[5:0] ISTAT1 IST(31:16) IENAM0 IENA(15:0) IENAM1 IENA(31:16) 6 CSS TMD IST(15:0) 7 0 RX EIE ACD ISTAT0 UART Registers RX IP 1 FCPRS 15 . . . 12 11 . . . 8 IVCT SCS RX EIP BCPRS ADMACR 2 5 4 UnTBUF UnTBUF UnRBUF URBUF 3 2 1 0 UnICTRL UEEI UERI UETI UEFCI UCTS UDCTS URBF UTBE UnSTAT Reserved UXMIP URB9 UBKD UERR UDOE UFE UPE UnFRS Reserved UPEN UXB9 USTP URTS UFCE UCKS UBRK UnMDSL1 UPSEL UERD UETD UnBAUD UnPSR UnOVR www.national.com UATN UMOD UDIV7:0 UPSC UDIV10:8 Reserved UnMDSL2 UnSPOS UCHAR UOVSR Reserved Reserved USMD USAMP 208 15 . . . 9 8 7 6 5 MWDAT 3 2 1 0 EIO ECHO MOD MNS MWEN OVR RBF BSY MWDAT MWCTL1 SCDV SCIDL SCM MWSTAT EIW EIR Reserved ACB Registers 7 6 5 4 ACBSDA 3 2 1 0 DATA ACBST ACBCST 4 SLVSTP SDAST BER NEGACK STASTR NMATCH MASTER XMIT TGSCL TSDA GMATCH MATCH BB BUSY GCMEN ACK Reserved INTEN STOP START ARPMATCH MATCHAF ACBCTL1 STASTRE ACBADDR SAEN NMINTE ADDR ACBCTL2 SCLFRQ[6:0] ACBADDR2 ENABLE SAEN ADDR ACBCTL3 Reserved TWM Registers 15 . . . 8 7 TWCFG Reserved TWCP Reserved ARPEN 6 5 Reserved 4 3 2 1 0 WDSDME WDCT0I LWDCNT LTWMT0 LTWCP LTWCFG Reserved TWMT0 MDIV PRESET T0CSR Reserved WDCNT Reserved PRESET WDSDM Reserved RSTDATA MFT16 Registers SCLFRQ[8:7] 15 . . . 8 Reserved 7 6 FRZT0E WDTLD 5 4 TCNT1 TCNT1 TCRA TCRA TCRB TCRB TCNT2 TCNT2 3 Reserved T0INTE 2 TC RST 1 0 TPRSC Reserved CLKPS TCKC Reserved TCTRL Reserved TEN TAOUT TBEN TAEN TBEDG TAEDG TICTL Reserved TDIEN TCIEN TBIEN TAIEN TDPND TCPND TBPND TAPND TICLR Reserved TDCLR TCCLR TBCLR TACLR Reserved C2CSEL Reserved 209 C1CSEL TMDSEL www.national.com CP3CN23 MWSPI16 Registers CP3CN23 VTU Registers 15 MODE 14 13 12 11 T8 T7 RUN RUN TMOD4 10 9 8 7 T6 T5 RUN RUN TMOD3 6 TMOD2 5 4 T4 T3 RUN RUN 3 2 TMOD1 1 0 T2 T1 RUN RUN IO1CTL P4 POL C4EDG P3 POL C3EDG P2 POL C2EDG P1 POL C1EDG IO2CTL P7 POL C7EDG P6 POL C6EDG P5 POL C5EDG P5 POL C5EDG INTCTL I4DEN I4CEN I4BEN I4AEN I3DEN I3CEN I3BEN I3AEN I2DEN I2CEN I2BEN I2AEN I1DEN I1CEN I1BEN I1AEN INTPND I4DPD I4CPD I4BPD I4APD I3DPD I3CPD I3BPD I3APD I2DPD I2CPD I2BPD I2APD I1DPD I1CPD I1BPD I1APD CLK1PS C2PRSC C1PRSC COUNT1 CNT1 PERCAP1 PCAP1 DTYCAP1 DCAP1 COUNT2 CNT2 PERCAP2 PCAP2 DTYCAP2 DCAP2 CLK2PS C4PRSC C3PRSC COUNT3 CNT3 PERCAP3 PCAP3 DTYCAP3 DCAP3 COUNT4 CNT4 PERCAP4 PCAP4 DTYCAP4 DCAP4 ADC Registers 15 14 13 12 11 10 9 8 ADCGCR MUXINTEN Res. NREF_CFG PREF_CFG OUTEN ADCACR CNVT TRG PRM ADCCNTRL 6 TOUCH_CFG 5 4 MUX_CFG Reserved 3 2 1 ADC_DIV ADC_DELAY1 ADC_ ADC_ PEN_ SIGN DONE OFLW DOWN www.national.com ADC_DELAY2 ADC_RESULT 210 CLKSEL AUTO EXT POL Write any value. ADCSCDLY 0 DIFF ADCIN CLKEN CLKDIV Reserved ADCSTART ADCRESLT 7 RNGCST 15 14 13 12 11 10 9 8 Reserved RNGDIVL 6 5 IMSK RNGD RNGDIVH 7 4 3 Reserved 2 1 0 DVALID RNGE RNGD Reserved RNGDIV17:16 RNGDIV15:0 211 www.national.com CP3CN23 RNG Registers CP3CN23 28.0 Electrical Characteristics 28.1 ABSOLUTE MAXIMUM RATINGS If Military/Aerospace specified devices are required, please contact the National Semiconductor Sales Office/Distributors for availability and specifications. Supply voltage (VCC) All input and output voltages with respect to GND* 3.6V -0.5V to IOVCC + 0.5V ESD protection level 2 kV (Human Body Model) Allowable sink/source current per signal pin 28.2 Total current into IOVCC pins Total current into VCC pins (source) Total current out of GND pins (sink) Latch-up immunity Storage temperature range 200 mA 200 mA 200 mA ±200 mA -65°C to +150°C Note: Absolute maximum ratings indicate limits beyond which damage to the device may occur. DC and AC electrical specifications are not ensured when operating the device at absolute maximum ratings. * The latch-up tolerance on Access Bus pins 14 and 15 exceeds 150mA. ±10 mA DC ELECTRICAL CHARACTERISTICS (Temperature: -40°C ≤ TA ≤ +85°C) Symbol Parameter Conditions Min Max Units Vcc Digital Logic Supply Voltage 2.25 2.75 V IOVcc I/O Supply Voltage 2.25 3.63 V AVcc Analog PLL Supply Voltage 2.25 2.75 V ADVcc ADC Supply Voltage 2.25 2.75 V 0.3 Vcc V a VIL Logical 0 Input Voltage (except X1CKI, X2CKI, and RESET) -0.5 VIH Logical 1 Input Voltage (except X1CKI, X2CKI, and RESET) 0.7 IOVcc IOVcc + 0.5 a V Vxl1 X1CKI Logical 0 Input Voltage External X1 clock -0.5 a 0.3 Vcc V Vxh1 X1CKI Logical 1 Input Voltage External X1 clock 0.7 Vcc Vcc + 0.5 V 0.6 V a Vxl2 X2CKI Logical 0 Input Voltage External X2 clock -0.5 Vxh2 X2CKI Logical 1 Input Voltage External X2 clock 0.7 Vcc Vcc + 0.5 V Vrstl RESET Logical 0 Input Voltage RESET input -0.5 0.4 V Vrsth RESET Logical 1 Input Voltage RESET input 1.7 V 0.1 IOVcc V a Vhys Hysteresis Loop Width IOH Logical 1 Output Current VOH = 1.8V, IOVcc = 2.25V -6 mA IOL Logical 0 Output Current VOL = 0.45V, IOVcc = 2.25V 6 mA IOLACB SDA, SCL Logical 0 Output Current VOL = 0.4V, IOVcc = 2.25V 3 mA IOLTS Touchscreen Logical 0 Output Current b (for ADC2/TSX- and ADC3/TSY-) VOL = 0.15V, ADVcc = 2.25V 18 mA IOHTS Touchscreen Logical 1 Output Current b (for ADC0/TSX+ and ADC1/TSY+) VOH = 2.1, ADVcc = 2.25V -18 mA IOHW Weak Pull-up Current VIL = 0V, IOVcc = 3.63V -20 -300 µA IL High Impedance Input Leakage Current c (except ADC0/TSX+, ADC1/TSY+, ADC2/TSX-, ADC3/TSY-) 0V ≤ Vin ≤ IOVcc -2.0 2.0 µA www.national.com 212 Parameter Conditions Min Max Units IL High Impedance Input Leakage Current (for ADC0/TSX+, ADC1/TSY+, ADC2/TSX-, ADC3/TSY-) 0V ≤ Vin ≤ IOVcc -5.0 5.0 µA IO(Off) Output Leakage Current (I/O pins in input mode) 0V ≤ Vout ≤ Vcc -2.0 2.0 µA Icca1 Digital Supply Current Active Mode d Vcc = 2.75V, IOVcc=3.63V 20 mA Iccprog Digital Supply Current Active Mode e Vcc = 2.75V, IOVcc = 3.63V 20 mA Iccps Digital Supply Current Power Save Mode f Vcc = 2.75V, IOVcc =3.63V 4 mA Iccid Digital Supply Current Idle Mode g Vcc = 2.75V, IOVcc = 3.63V 2 mA Iccq Digital Supply Current Halt Mode g,h Vcc = 2.75V, IOVcc = 3.63V, 20°C 150 µA a. Guaranteed by design b. Characterized not tested in production. c. Some pins not tested for leakage due to I/O structure. d. Run from internal memory (RAM), Iout = 0 mA, X1CKI = 12 MHz, PLL enabled (4×), internal system clock is 24 MHz, not programming Flash memory e. Same conditions as Icca1, but programming or erasing Flash memory page f. Running from internal memory (RAM), Iout = 0 mA, XCKI1 = 12 MHz, PLL disabled, X2CKI = 32.768 kHz, device put in power-save mode, Slow Clock derived from XCKI1 g. Iout = 0 mA, XCKI1 = Vcc, X2CKI = 32.768 kHz h. Halt current approximately doubles for every 20°C. 28.3 ADC ELECTRICAL CHARACTERISTICS (Temperature: -40°C ≤ TA ≤ +85°C) Symbol Parameter Conditions Min Typ Max Units VPREF ADC Positive Reference Input a 2 2.75 V VNREF ADC Negative Reference Input a 0 0.25 V VPREF V ADC Input Range a VNREF Clock Frequency 12 MHz tC Conversion Time (12-bit result) 14 µs INL Integral Non-Linearity DNL Differential Non-Linearity CADCIN Total Capacitance of ADC Input a a CADCINS Switched Capacitance of ADC Input RADCIN Resistance of ADC Input Path a CADCIN Total Capacitance of ADC Reference Input a CADCINS RADCIN Switched Capacitance of ADC Reference Input Resistance of ADC Reference Input Path a a ±2 LSB ±0.7 LSB 9 20 pF 8 10 pF 0.1 12 kohm 50 100 pF 8 10 pF 0.2 0.6 kohm a. Guaranteed by design 213 www.national.com CP3CN23 Symbol CP3CN23 28.4 FLASH MEMORY ON-CHIP PROGRAMMING (Guaranteed by design.) Symbol Parameter Conditions Min Max Units - µs tSTART Program/Erase to NVSTR Setup Timea (NVSTR = Non-Volatile Storage 5 tTRAN NVSTR to Program Setup Timeb 10 - µs tPROG Programming Pulse Widthc 20 40 µs tPERASE Page Erase Pulse Widthd 20 - ms tMERASE Module Erase Pulse Widthe 200 - ms f tEND NVSTR Hold Time tMEND NVSTR Hold Time (Module Erase)g tRCV Recovery Timeh tHV Cumulative Program High Voltage Period For Each Row After Erasei tHV 5 - µs 100 - µs 1 - µs 128K program blocks - 8 ms 8K data block - 4 ms 20,000 - cycles 100 - years Write/Erase Endurance Data Retention 25°C a. Program/erase to NVSTR Setup Time is determined by the following equation: tSTART = Tclk × (FTDIV + 1) × (FTSTART + 1), where Tclk is the System Clock period, FTDIV is the contents of the FMPSR or FSMPSR register, and FTSTART is the contents of the FMSTART or FSMSTART register b. NVSTR to Program Setup Time is determined by the following equation: tTRAN = Tclk × (FTDIV + 1) × (FTTRAN + 1), where Tclk is the System Clock period, FTDIV is the contents of the FMPSR or FSMPSR register, and FTTRAN is the contents of the FMTRAN or FSMTRAN register c. Programming Pulse Width is determined by the following equation: tPROG = Tclk × (FTDIV + 1) × 8 × (FTPROG + 1), where Tclk is the System Clock period, FTDIV is the contents of the FMPSR or FSMPSR register, and FTPROG is the contents of the FMPROG or FSMPROG register d. Page Erase Pulse Width is determined by the following equation: tPERASE = Tclk × (FTDIV + 1) × 4096 × (FTPER + 1), where Tclk is the System Clock period, FTDIV is the contents of the FMPSR or FSMPSR register, and FTPER is the contents of the FMPERASE or FSMPERASE register e. Module Erase Pulse Width is determined by the following equation: tMERASE = Tclk × (FTDIV + 1) × 4096 × (FTMER + 1), where Tclk is the System Clock period, FTDIV is the contents of the FMPSR or FSMPSR register, and FTMER is the contents of the FMMERASE0 or FSMMERASE0 register f. NVSTR Hold Time is determined by the following equation: tEND = Tclk × (FTDIV + 1) × (FTEND + 1), where Tclk is the System Clock period, FTDIV is the contents of the FMPSR or FSMPSR register, and FTEND is the contents of the FMEND or FSMEND register g. NVSTR Hold Time (Module Erase) is determined by the following equation: tMEND = Tclk × (FTDIV + 1) × 8 × (FTMEND + 1), where Tclk is the System Clock period, FTDIV is the contents of the FMPSR or FSMPSR register, and FTMEND is the contents of the FMMEND or FSMMEND register h. Recovery Time is determined by the following equation: tRCV = Tclk × (FTDIV + 1) × (FTRCV + 1), where Tclk is the System Clock period, FTDIV is the contents of the FMPSR or FSMPSR register, and FTRCV is the contents of the FMRCV or FSMRCV register i. Cumulative program high voltage period for each row after erase tHV is the accumulated duration a flash cell is exposed to the programming voltage after the last erase cycle. www.national.com 214 OUTPUT SIGNAL LEVELS The RESET and NMI input pins are active during the Power Save mode. In order to guarantee that the Power Save curAll output signals are powered by the digital supply (VCC). rent not exceed 1 mA, these inputs must be driven to a voltTable 73 summarizes the states of the output signals during age lower than 0.5V or higher than VCC - 0.5V. An input the reset state (when VCC power exists in the reset state) voltage between 0.5V and (VCC - 0.5V) may result in power and during the Power Save mode. consumption exceeding 1 mA. Table 73 Output Pins During Reset and Power-Save Reset State (with Vcc) Signals on a Pin Power Save Mode PB7:0 TRI-STATE Previous state PC7:0 TRI-STATE Previous state PE5:0 TRI-STATE Previous state PF7:0 TRI-STATE Previous state PG7:0 TRI-STATE Previous state PH7:0 TRI-STATE Previous state PJ7:0 TRI-STATE Previous state 28.6 Comments I/O ports will maintain their values when entering power-save mode CLOCK AND RESET TIMING (Guaranteed by design. All timing except memory interface characterized not tested for production.) Table 74 Clock and Reset Signals Symbol Figure Description Reference Min (ns) Max (ns) 83.33 83.33 Clock Input Signals tX1p 92 X1 period Rising Edge (RE) on X1 to next RE on X1 tX1h 92 X1 high time, external clock At 2V level (Both Edges) (0.5 Tclk) - 5 tX1l 92 X1 low time, external clock At 0.8V level (Both Edges) (0.5 Tclk) - 5 RE on X2 to next RE on X2 10,000 perioda tX2p 92 X2 tX2h 92 X2 high time, external clock At 2V level (both edges) (0.5 Tclk) - 500 tX2l 92 X2 low time, external clock At 0.8V level (both edges) (0.5 Tclk) - 500 tIH 93 Input hold time (NMI, RXD1, RXD2) After RE on CLK 0 Reset and NMI Input Signals tIW 93 NMI Pulse Width NMI Falling Edge (FE) to RE 20 tRST 94 RESET Pulse Width RESET FE to RE 100 tR 94 Vcc Rise Time 0.1 Vcc to 0.9 Vcc a. Only when operating with an external square wave on X2CKI; otherwise a 32 kHz crystal network must be used between X2CKI and X2CKO. If Slow Clock is internally generated from Main Clock, it may not exceed this given limit. 215 www.national.com CP3CN23 28.5 CP3CN23 tX1p X1CKI tX1h tX1l tX2p X2CKI tX2h tX2l DS095 Figure 92. Clock Timing CLK tlS tlH tIW NMI DS096 Figure 93. NMI Signal Timing CLK tRST RESET DS097 Figure 94. Non-Power-On Reset 0.9 VCC VCC 0.1 VCC tR Figure 95. www.national.com DS115 Power-On Reset 216 CP3CN23 28.7 UART TIMING Table 75 UART Signals Symbol Figure Description Reference Min (ns) Max (ns) 250 - UART Input Signals tCKX 96 CKX period (synchronous mode) tRXS 96 RXD setup time (synchronous mode) Before Falling Edge (FE) on CKX 40 - tRXH 96 RXD hold time (synchronous mode) Before FE on CKX 40 - - 40 UART Output Signals tTXD 96 TXD output valid (synchronous mode) After Rising Edge (RE) on CKX tCKX CKX tTXD TXD tRXS RXD tRXH DS099 Figure 96. UART Synchronous Mode Timing 217 www.national.com CP3CN23 28.8 I/O PORT TIMING Table 76 I/O Port Signals Symbol Figure Description Reference Min (ns) Max (ns) I/O Port Input Signals tIS 97 Input Setup Time Before Falling Edge (FE) on System Clock 22.5 - tIH 97 Input Hold Time After FE on System Clock 0 - - 3 I/O Port Output Signals tCOv1 97 Output Valid Time After FE on System Clock CLK tIS Port Input tlH Port Output tCOv1 tCOv1 DS100 Figure 97. I/O Port Timing www.national.com 218 CP3CN23 28.9 ADVANCED AUDIO INTERFACE (AAI) TIMING Table 77 Advanced Audio Interface (AAI) Signals Symbol Figure Description Reference Min (ns) Max (ns) AAI Input Signals tRDS 98, 100 Receive Data Setup Time Before Falling Edge (FE) on SRCLK 20 - tRDH 98, 100 Receive Data Hold Time After FE on SRCLK 20 - tFSS 98 Frame Sync Setup Time Before Rising Edge (RE) on SRCLK 20 - tFSH 98 Frame Sync Hold Time After RE on SRCLK 20 - AAI Output Signals tCP 98 Receive/Transmit Clock Period RE on SRCLK/SCK to RE on SRCLK/SCK 976.6 - tCL 98 Receive/Transmit Low Time FE on SRCLK/SCK to RE on SRCLK/SCK 488.3 - tCH 98 Receive/Transmit High Time RE on SRCLK/SCK to FE on SRCLK/SCK 488.3 - tFSVH 98, 100 Frame Sync Valid High RE on SRCLK/SCK to RE on SRFS/SFS - 20 tFSVL 98, 100 Frame Sync Valid Low RE on SRCLK/SCK to FE on SRFS/SFS - 20 tTDV 99, 101 Transmit Data Valid RE on SCK to STD Valid - 20 tCP SRCLK 0 1 tCH 2 tCL SRFS tFSVH tFSVL SRD 0 1 tRDH tRDS DS116 Figure 98. Receive Timing, Short Frame Sync 219 www.national.com CP3CN23 SCK 0 1 2 SFS STD 0 1 tTDV DS117 Figure 99. SRCLK 0 Transmit Timing, Short Frame Sync 1 2 N SRFS tFSVL tFSVH SRD 0 tRDH tRDS DS118 Figure 100. SCK 1 0 Receive Timing, Long Frame Sync 1 2 N SFS STD 0 1 tTDV DS119 Figure 101. www.national.com Transmit Timing, Long Frame Sync 220 CP3CN23 28.10 MICROWIRE/SPI TIMING Table 78 Microwire/SPI Signals Symbol Figure Description Reference Min (ns) Max (ns) Microwire/SPI Input Signals tMSKh 102 Microwire Clock High At 2.0V (both edges) 80 - tMSKl 102 Microwire Clock Low At 0.8V (both edges) 80 - SCIDL bit = 0; Rising Edge (RE) MSK to next RE MSK 102 tMSKp Microwire Clock Period SCIDL bit = 1; Falling Edge (FE) MSK to next FE MSK 103 200 - tMSKh 102 MSK Hold (slave only) After MWCS goes inactive 40 - tMSKs 102 MSK Setup (slave only) Before MWCS goes active 80 - SCIDL bit = 0: After FE MSK 102 MWCS Hold (slave only) tMWCSh 103 SCIDL bit = 1: After RE MSK 102 SCIDL bit = 0: Before RE MSK tMWCSs MWCS Setup (slave only) 103 SCIDL bit = 1: Before FE MSK 102 Normal Mode: After RE MSK Microwire Data In Hold (master) 104 Alternate Mode: After FE MSK 102 Normal Mode: After RE MSK tMDIh Microwire Data In Hold (slave) 104 Alternate Mode: After FE MSK 102 Normal Mode: Before RE MSK Microwire Data In Setup tMDIs Alternate Mode: Before FE MSK 104 40 80 0 40 80 - Microwire/SPI Output Signals tMSKh 102 Microwire Clock High At 2.0V (both edges) 40 - tMSKl 102 Microwire Clock Low At 0.8V (both edges) 40 - 102 tMSKp Microwire Clock Period 103 SCIDL bit = 0: Rising Edge (RE) MSK to next RE MSK SCIDL bit = 1: Falling Edge (FE) MSK to next FE MSK tMSKd 102 MSK Leading Edge Delayed (master only) Data Out Bit #7 Valid tMDOf 102 Microwire Data Float b (slave only) After RE on MWCS 102 tMDOh Microwire Data Out Hold 103 tMDOnf 106 Microwire Data No Float (slave only) Normal Mode: After FE MSK Alternate Mode: After RE MSK After FE on MWCS 221 100 0.5 tMSK 1.5 tMSK - 25 - 0.0 0 25 www.national.com CP3CN23 Table 78 Microwire/SPI Signals Symbol Figure tMDOv tMITOp Description 102 Microwire Data Out Valid 106 MDODI to MDIDO (slave only) Reference Normal Mode: After FE on MSK Alternate Mode: After RE on MSK Propagation Time Value is the same in all clocking modes of the Microwire Min (ns) Max (ns) - 25 - 25 tMSKp MSK tMSKh tMSKs Data In tMSKl tMSKhd msb tMDls MDIDO (slave) lsb tMDlh msb lsb tMDOf tMDOv tMDOff tMDOh MDODI (master) msb lsb tMSKd MCS (slave) tMCSs tMCSh Figure 102. Microwire Transaction Timing, Normal Mode, SCIDL = 0 www.national.com 222 DS101 CP3CN23 tMSKp MSK tMSKh tMSKh tMSKhd tMSKs Data In msb tMDls MDIDO (slave) lsb tMDlh msb lsb tMDOv tMDOf tMDOf tMDOh MDODO (master) msb lsb MCS (slave) tMCSs tMCSh DS102 Figure 103. Microwire Transaction Timing, Normal Mode, SCIDL = 1 223 www.national.com CP3CN23 tMSKp MSK tMSKhd tMSKs tMSKh Data In tMSKl msb tMDls MDIDO (slave) lsb tMDlh msb lsb tMDOv tMDOf tMDOf tMDOh MDODO (master) msb lsb MCS (slave) tMCSs Figure 104. www.national.com tMCSh Microwire Transaction Timing, Alternate Mode, SCIDL = 0 224 DS103 CP3CN23 tMSKp MSK tMSKhd tMSKs tMSKh Data In tMSKh msb lsb tMDlh tMDls MDIDO (slave) msb lsb tMDOf tMDOv tMDOff tMDOh MDODI (master) msb lsb tSKd MCS (slave only) tMCSs Figure 105. tMCSh DS104 Microwire Transaction Timing, Alternate Mode, SCIDL = 1 tMSKp MSK tMSKhd tMSKs tMSKh MDODI (slave) tMSKl Dl msb tMDls Dl lsb tMDlh tMITOp MDIDO (slave) tMITOp DO msb DO lsb tMDOnf tMDOf MCS tMCSs tMCSh DS105 Figure 106. Microwire Transaction Timing, Data Echoed to Output, Normal Mode, SCIDL = 0, ECHO = 1, Slave Mode 225 www.national.com CP3CN23 28.11 ACCESS.BUS TIMING Table 79 ACCESS.bus Signals Symbol Figure Description Reference Min (ns) Max (ns) tSCLhigho - ACCESS.bus Input Signals tBUFi 108 Bus free time between Stop and Start Condition tCSTOsi 108 SCL setup time Before Stop Condition tCSTRhi 108 SCL hold time After Start Condition (8 × tCLK) - tSCLri (8 × tCLK) - tSCLri tCSTRsi 108 SCL setup time Before Start Condition (8 × tCLK) - tSCLri - 2 × tCLK - - tDHCsi 109 Data High setup time Before SCL Rising Edge (RE) tDLCsi 108 Data Low setup time Before SCL RE 2 × tCLK - tSCLfi 107 SCL signal rise time - 300 tSCLri 107 SCL signal fall time - 1000 tSCLlowi 110 SCL low time After SCL Falling Edge (FE) 16 × tCLK - tSCLhighi 110 SCL high time After SCL RE - tSDAri 107 SDA signal rise time 16 × tCLK - 1000 tSDAfl 107 SDA signal fall time tSDAhi 110 SDA hold time After SCL FE tSDAsi 110 SDA setup time Before SCL RE - 300 0 - 2 × tCLK - ACCESS.bus Output Signals tBUFo 108 Bus free time between Stop and Start Condition tCSTOso 108 SCL setup time tCSTRho 108 SCL hold time tCSTRso 109 SCL setup time tDHCso 109 Data High setup time tDLCso 108 Data Low setup time tSCLfo 107 tSCLro 107 tSCLlowo 110 tSCLhigho - tSCLhigho - After Start Condition tSCLhigho - Before Start Condition tSCLhigho - Before SCL R.E. tSCLhigho -tSDAro - Before SCL R.E. tSCLhigho -tSDAfo - SCL signal Fall time - 300c SCL signal Rise time - SCL low time Before Stop Condition After SCL F.E. -d (K × tCLK) -1e - (K × tCLK) -1e - tSCLhigho 110 SCL high time tSDAfo 107 SDA signal Fall time - 300 tSDAro 107 SDA signal Rise time - - tSDAho 110 SDA hold time After SCL F.E. (7 × tCLK) - tSCLfo - tSDAvo 110 SDA valid time After SCL F.E. www.national.com After SCL R.E. 226 (7 × tCLK) + tRD 0.7VCC 0.3VCC 0.3VCC CP3CN23 0.7VCC SDA tSDAr tSDAf 0.7VCC 0.7VCC 0.3VCC 0.3VCC SCL tSCLr tSCLf Note: In the timing tables the parameter name is added with an "o" for output signal timing and "i" for input signal timing. DS106 Figure 107. ACB Signals (SDA and SCL) Timing Stop Condition Start Condition SDA tDLCs SCL tCSTOs tBUF tCSTRh Note: In the timing tables the parameter name is added with an "o" for output signal timing and "i" for input signal timing. DS107 Figure 108. ACB Start and Stop Condition Timing Start Condition SDA SCL tCSTRh tCSTRs tDHCs Note: In the timing tables the parameter name is added with an "o" for output signal timing and "i" for input signal timing. DS108 Figure 109. ACB Start Condition Timing 227 www.national.com CP3CN23 SDA tSDAsi SCL tSCAvo tSDAh tCSLlow tSCLhigh Note: In the timing tables the parameter name is added with an "o" for output signal timing and "i" for input signal timing. unless the parameter already includes the suffix. DS109 Figure 110. www.national.com ACB Data Timing 228 CP3CN23 28.12 MULTI-FUNCTION TIMER (MFT) TIMING Table 80 Multi-Function Timer Input Signals Symbol Figure Description Reference Min (ns) tTAH 111 TA High Time Rising Edge (RE) on CLK TCLK + 5 tTAL 111 TA Low Time RE on CLK TCLK + 5 tTBH 111 TB High Time RE on CLK TCLK + 5 tTBL 111 TB Low Time RE on CLK TCLK + 5 Max (ns) CLK tTAL /tTBH tTAL /tTBL TA/TB DS169 Figure 111. Multi-Function Timer Input Timing 229 www.national.com CP3CN23 28.13 VERSATILE TIMING UNIT (VTU) TIMING Table 81 Versatile Timing Unit Input Signals Symbol Figure Description Reference tTIOH 112 TIOx Input High Time Rising Edge (RE) on CLK tTIOL 112 TIOx Input Low Time RE on CLK Min (ns) 1.5 × TCLK + 5ns 1.5 × TCLK + 5ns CLK tTIOL tTIOH TIOx DS110 Figure 112. Versatile Timing Unit Input Timing www.national.com 230 Max (ns) CP3CN23 28.14 EXTERNAL BUS TIMING Table 82 Symbol Figure External Bus Signals Description Reference Min (ns) Max (ns) External Bus Input Signals t1 113, 115, Input Setup Time 116, D[15:0] 117 Before Rising Edge (RE) on CLK 8 - t2 113, 115, Output Hold Time 116, D[15:0] 117 After RE on CLK 0 - External Bus Output Signals t3 113, Output Valid Time 114 D[15:0] After RE on CLK - 8 t4 113, 114, Output Valid Time 115, A[22:0] 116, 117 After RE on CLK - 8 t5 113, 114, 115, 116, 117 Output Active/Inactive Time RD SEL[1:0] SELIO After RE on CLK - 8 t6 113, Output Active/Inactive Time 114 WR[1:0] After RE on CLK - 0.5 Tclk + 8 t7 115 Minimum Inactive Time RD At 2.0V Tclk - 4 - t8 113 Output Float Time D[15:0] After RE on CLK - 8 t9 113 Minimum Delay Time From RD Trailing Edge (TE) to D[15:0] driven Tclk - 4 - t10 113, Minimum Delay Time 114 From RD TE to SELn Leading Edge (LE) 0 - t11 114 Minimum Delay Time From SELx TE to SELy LE 0 - t12 113, 114, 115, 116, 117 Output Hold Time A[22:0] D[15:0] RD SEL[2:0] SELIO After RE on CLK 0 - t13 113, Output Hold Time 114 WR[1:0] After RE on CLK 0.5 Tclk - 3 - 231 www.national.com CP3CN23 Normal Read Bus State T1 Early Write T2 T1 T2 Normal Read T3 T1 T2 CLK t4 t4, t12 t5, t12 t5, t12 A[21:0] A22 ('13 only) SELx t5, t12 t5, t12 SELy (y ≠ x) t2 t3 D[15:0] In t1 t8, t12 Out In t5, t12 t5, t12 RD t9 t6, t13 t6, t13 WR[1:0] DS124 Figure 113. www.national.com Early Write Between Normal Read Cycles (No Wait States) 232 Bus State T1 Late Write T2 T1 CP3CN23 Normal Read Normal Read T2 T1 T2 CLK t4, t12 t4, t12 A[21:0] A22 ('13 only) t5, t12 t5, t12 SELx (y ≠ x) t11 SELy (y ≠ x) t5, t12 t5, t12 t3 D[15:0] t8, t12 In Out In t10 RD t9 t5, t12 t5, t12 t6, t13 WR[1:0] t6, t13 DS125 Figure 114. Late Write Between Normal Read Cycles (No Wait States) 233 www.national.com CP3CN23 Normal Read T1 Bus State Normal Read T2 T2B T1 T2 T2B CLK t4, t12 t4, t12 t4 A[21:0] A22 ('13 only) t5, t12 t5, t12 SELx (y ≠ x) t5, t12 SELy (y ≠ x) t5, t12 t2 t2 t1 D[15:0] t1 In In In In t5, t12 RD t5, t12 t7 WR[1:0] DS126 Figure 115. Consecutive Normal Read Cycles (Burst, No Wait States) www.national.com 234 TW T2 CP3CN23 T1 Bus State TH CLK t4, t12 t4 A21:0 A22 ('13 only) t5, t12 t5, t12 SELn, SELIO t2 t1 D[15:0] t5, t12 t5, t12 RD WR[1:0] DS127 Figure 116. Normal Read Cycle (Wait Cycle Followed by Hold Cycle) 235 www.national.com CP3CN23 Fast Read Bus State Tidle Early Write T1-2 T1 T2 Fast Read T3 T1-2 T1 CLK t4, t12 t4 A[21:0] A22 ('13 only) SELx (y ≠ x) t5, t12 t5, t12 SELy (y ≠ x) t1 t2 D[15:0] In Out In RD t5, t12 t5, t12 WR[1:0] DS128 Figure 117. Early Write Between Fast Read Cycles www.national.com 236 29.1 LQFP-128 PACKAGE TDI TMS RESET ADC7/ADCIN ADC6 ADC5/MUXOUT1 ADC4/MUXOUT0 ADC3/TSYADC2/TSXADC1/TSY+ ADC0/TSX+ VREF ADGND ADVCC PE3/CTS PE0/RXD0 PE2/RTS GND VCC PE1/TXD0 SDA SCL IOVCC IOGND VCC GND IOGND IOVCC IOVCC PG5 PG4 PG3 PG1 PG0 NC IOGND PJ6/WUI24 PJ5/WUI23 For 128-pin devices, Figure 118 provides a pinout diagram, and Table 83 provides the pin assignments. The physical dimensions are provided in Section 31.0. 65 TCK PJ7/ASYNC/WUI9 PH0/RXD1/WUI11 TDO IOVCC RDY PF3/MWCS/TIO4 IOGND PF0/MSK/TIO1 GND VCC PF1/MDIDO/TIO2 IOVCC PF2/MDODI/TIO3 IOGND PG2/SRCLK IOGND PE5/SRFS/NMI IOVCC PF4/SCK/TIO5 PF5/SFS/TIO6 IOGND PF6/STD/TIO7 PF7/SRD/TIO8 IOVCC PJ0 103 CP3CN23 (LQFP-128) 39 PJ4/WUI22 IOVCC PE7/CAN1TX PE6/CAN1RX IOGND PH7/CAN0TX IOVCC PH6/CAN0RX/WUI17 GND VCC PH5/TXD3/WUI16 IOGND PH4/RXD3/WUI15 IOVCC PH3/TXD2/WUI14 IOGND PH2/RXD2/WUI13 IOVCC PH1/TXD1/WUI12 IOGND IOVCC IOGND IOVCC PG7/TA PE4/CKX/TB PJ3/WUI21 PJ1/WUI19 PC7 PC6 IOGND PC5 PC4 IOVCC PC3 PC2 IOGND PC1 PC0 IOVCC PB7 PB6 PB5 IOGND PB4 PB3 PB2 IOVCC PB1 PB0 GND VCC X1CKO X1CKI/BBCLK AGND AVCC X2CKI X2CKO VCC GND ENV2/SLOWCLK ENV1/CPUCLK ENV0/PLLCLK PG6/WUI10 PJ2/WUI20 1 DS308 Figure 118. CP3CN23 in the LQFP-128 Package (Top View) Table 83 Pin Assignments for LQFP-128 Package Pin Name Pin Numbers Type GND 24, 33, 56, 77, 85, 112 PWR VCC 25, 32, 55, 78, 84, 113 PWR IOGND 4, 10, 17, 43, 45, 49, 53, 60, 67, 76, 79, 110, 117, 119, 124 PWR IOVCC 7, 13, 21, 42, 44, 47, 51, 58, 63, 74, 75, 80, 107, 115, 121, 127 PWR X1CKO 26 O 27 I 28 PWR X1CKI Alternate Function(s) BBCLK AGND 237 www.national.com CP3CN23 29.0 Pin Assignments CP3CN23 Table 83 Pin Assignments for LQFP-128 Package Pin Name Alternate Function(s) Pin Numbers Type AVCC 29 PWR ADGND 90 PWR ADVCC 89 PWR X2CKI 30 I X2CKO 31 O ENV2 SLOWCLK 34 I/O ENV1 CPUCLK 35 I/O ENV0 PLLCLK 36 I/O RESET 100 I TMS 101 I TDI 102 I TCK 103 I TDO 106 O RDY 108 O SCL 81 I/O SDA 82 I/O ADC0 TSX+ 92 I/O/HIZ 20mA+ ADC1 TSY+ 93 I/O/HIZ 20mA+ ADC2 TSX- 94 I/O/HIZ 20mA+ ADC3 TSY- 95 I/O/HIZ 20mA+ ADC4 MUXOUT0 96 I/O ADC5 MUXOUT1 97 I/O 98 I ADCIN 99 I 91 I PB0 D0 23 GPIO PB1 D1 22 GPIO PB2 D2 20 GPIO PB3 D3 19 GPIO PB4 D4 18 GPIO PB5 D5 16 GPIO PB6 D6 15 GPIO ADC6 ADC7 VREFP PB7 D7 14 GPIO PC0 D8 12 GPIO PC1 D9 11 GPIO PC2 D10 9 GPIO PC3 D11 8 GPIO PC4 D12 6 GPIO PC5 D13 5 GPIO PC6 D14 3 GPIO PC7 D15 2 GPIO PE0 RXD0 87 GPIO PE1 TXD0 83 GPIO www.national.com 238 Pin Name Alternate Function(s) Pin Numbers Type PE2 RTS 86 GPIO PE3 CTS 88 GPIO PE4 CKX/TB 40 GPIO PE5 SRFS/NMI 120 GPIO PE6 CAN1RX 61 I/O PE7 CAN1TX 62 I/O PF0 MSK/TIO1 111 GPIO PF1 MDIDO/TIO2 114 GPIO PF2 MDODI/TIO3 116 GPIO PF3 MWCS/TIO4 109 GPIO PF4 SCK/TIO5 122 GPIO PF5 SFS/TIO6 123 GPIO PF6 STD/TIO7 125 GPIO PF7 SRD/TIO8 126 GPIO PG0 69 GPIO PG1 70 GPIO PG2 118 GPIO PG3 SRCLK 71 GPIO PG4 72 GPIO PG5 73 GPIO PG6 WUI10 37 GPIO PG7 TA 41 GPIO PH0 RXD1/WUI11 105 GPIO PH1 TXD1/WUI12 46 GPIO PH2 RXD2/WUI13 48 GPIO PH3 TXD2/WUI14 50 GPIO PH4 RXD3/WUI15 52 GPIO PH5 TXD3/WUI16 54 GPIO PH6 CAN0RX/WUI17 57 GPIO PH7 CAN0TX 59 GPIO PJ0 WUI18 128 GPIO PJ1 WUI19 1 GPIO PJ2 WUI20 38 GPIO PJ3 WUI21 39 GPIO PJ4 WUI22 64 GPIO PJ5 WUI23 65 GPIO PJ6 WUI24 66 GPIO PJ7 ASYNC/WUI9 104 GPIO Note 1: The ENV0, ENV1, ENV2, RESET, TCK, TDI, and TMS pins each have a weak pull-up to keep the input from floating. Note 2: These functions are always enabled, due to the direct low-impedance path to these pins. 239 www.national.com CP3CN23 Table 83 Pin Assignments for LQFP-128 Package LQFP-144 PACKAGE TDI TMS RESET ADC7/ADCIN ADC6 ADC5/MUXOUT1 ADC4/MUXOUT0 ADC3/TSYADC2/TSXADC1/TSY+ ADC0/TSX+ VREF ADGND ADVCC PE3/CTS PE0/RXD0 PE2/RTS GND VCC PE1/TXD0 SDA SCL VCC GND IOGND SELIO SEL2 SEL1 IOVCC SEL0 PG5 PG4 PG3 PG1 PG0 NC For 144-pin devices, Figure 119 provides a pinout diagram, and Table 84 provides the pin assignments. The physical dimensions are provided in Section 31.0. TCK PJ7/ASYNC/WUI9 PH0/RXD1/WUI11 TDO RDY A0 PF3/MWCS/TIO4 A1 IOGND A2 A3 PF0/MSK/TIO1 GND VCC PF1/MDIDO/TIO2 A4 A5 IOVCC PF2/MDODI/TIO3 A6 A7 IOGND A8 A9 PG2/SRCLK PE5/SRFS/NMI PF4/SCK/TIO5 PF5/SFS/TIO6 PF6/STD/TIO7 PF7/SRD/TIO8 A10 IOVCC A11 A12 A13 PJ0/WUI18 73 109 CP3CN23 (LQFP-144) 37 IOVCC PE7/CAN1TX PE6/CAN1RX WR1 WR0 IOGND RD PH7/CANTX IOVCC A22 A21 A20 PH6/CANRX/WUI17 GND VCC PH5/TXD3/WUI16 IOGND A19 A18 PH4/RXD3/WUI15 IOVCC PH3/TXD2/WUI14 IOGND PH2/RXD2/WUI13 IOVCC PH1/TXD1/WUI12 IOGND A17 IOVCC IOGND A16 IOVCC A15 A14 PG7/TA PE4/CKX/TB 1 PC7 PC6 IOGND PC5 PC4 IOVCC PC3 PC2 IOGND PC1 PC0 IOVCC PB7 PB6 PB5 IOGND PB4 PB3 PB2 IOVCC PB1 PB0 GND VCC X1CKO X1CKI/BBCLKO AGND AVCC X2CKI X2CKO VCC GND ENV2/SLOWCLK ENV1/CPUCLK ENV0/PLLCLK PG6/WUI10 CP3CN23 29.2 DS309 Figure 119. www.national.com CP3CN23 in the LQFP-144 Package (Top View) 240 Pin Name Alternate Function(s) Pin Number Type GND 23, 32, 59, 85, 91, 121 PWR VCC 24, 31, 58, 86, 90, 122 PWR IOGND 3, 9, 16, 43, 46, 50, 56, 67, 84, 117, 130 PWR IOVCC 6, 12, 20, 41, 44, 48, 52, 64, 72, 80, 126, 140 PWR AGND 27 PWR AVCC 28 PWR ADGND 96 PWR ADVCC 95 PWR 26 I X1CKO 25 O X2CKI 29 I X1CKI BBCLK X2CKO 30 O ENV2 SLOWCLK 33 I/O ENV1 CPUCLK 34 I/O ENV0 PLLCLK 35 I/O RESET 106 I TMS 107 I TDI 108 I TCK 109 I TDO 112 O RDY 113 O SCL 87 I/O SDA 88 I/O ADC0 TSX+ 98 I/O/HIZ 20mA+ ADC1 TSY+ 99 I/O/HIZ 20mA+ ADC2 TSX- 100 I/O/HIZ 20mA+ ADC3 TSY- 101 I/O/HIZ 20mA+ ADC4 MUXOUT0 102 I/O ADC5 MUXOUT1 103 I/O 104 I ADCIN 105 I 97 I PB0 D0 22 GPIO PB1 D1 21 GPIO PB2 D2 19 GPIO PB3 D3 18 GPIO PB4 D4 17 GPIO PB5 D5 15 GPIO PB6 D6 14 GPIO PB7 D7 13 GPIO PC0 D8 11 GPIO ADC6 ADC7 VREFP 241 www.national.com CP3CN23 Table 84 Pin Assignments for LQFP-144 Package CP3CN23 Pin Name Alternate Function(s) Pin Number Type PC1 D9 10 GPIO PC2 D10 8 GPIO PC3 D11 7 GPIO PC4 D12 5 GPIO PC5 D13 4 GPIO PC6 D14 2 GPIO PC7 D15 1 GPIO PE0 RXD0 93 GPIO PE1 TXD0 89 GPIO PE2 RTS 92 GPIO PE3 CTS 94 GPIO PE4 CKX/TB 37 GPIO PE5 SRFS/NMI 134 GPIO PE6 CAN1RX 70 GPIO PE7 CAN1TX 71 GPIO PF0 MSK/TIO1 120 GPIO PF1 MDIDO/TIO2 123 GPIO PF2 MDODI/TIO3 127 GPIO PF3 MWCS/TIO4 115 GPIO PF4 SCK/TIO5 135 GPIO PF5 SFS/TIO6 136 GPIO PF6 STD/TIO7 137 GPIO PF7 SRD/TIO8 138 GPIO PG0 74 GPIO PG1 75 GPIO PG2 www.national.com 133 GPIO PG3 SRCLK 76 GPIO PG4 77 GPIO PG5 78 GPIO PG6 WUI10 36 GPIO PG7 TA 38 GPIO PH0 RXD1/WUI11 111 GPIO PH1 TXD1/WUI12 47 GPIO PH2 RXD2/WUI13 49 GPIO PH3 TXD2/WUI14 51 GPIO PH4 RXD3/WUI15 53 GPIO PH5 TXD3/WUI16 57 GPIO PH6 CAN0RX/WUI17 60 GPIO PH7 CAN0TX 65 GPIO PJ0 WUI18 144 GPIO PJ7 ASYNC 110 GPIO A22 63 O A21 62 O A20 61 O 242 Alternate Function(s) Pin Number Type A19 55 O A18 54 O A17 45 O A16 42 O A15 40 O A14 39 O A13 143 O A12 142 O A11 141 O A10 139 O A9 132 O A8 131 O A7 129 O A6 128 O A5 125 O A4 124 O A3 119 O A2 118 O A1 116 O A0 114 O SEL0 79 O SEL1 81 O SEL2 82 O SELIO 83 O RD 66 O WR0 68 O WR1 69 O Note 1: The ENV0, ENV1, ENV2, RESET, TCK, TDI, and TMS pins each have a weak pull-up to keep the input from floating. Note 2: These functions are always enabled, due to the direct low-impedance path to these pins. 243 www.national.com CP3CN23 Pin Name CP3CN23 30.0 Revision History Table 85 Revision History Date Major Changes From Previous Version 10/7/03 Original release. 11/14/03 Defined valid range of SCDV field in Microwire/SPI module. Noted default PRSSC register value generates a Slow Clock frequency slightly higher than 32768 Hz. Clarified usage of CVSTAT register bits and fields in CVSD/PCM module. Added usage hint for avoiding ACCESS.bus module bus error. Added usage hint for avoiding CAN unexpected loopback condition. 2/28/04 Changed NSID designations in the product selection guide. Added entry for CTIM register in CAN section register list. Changed CVSD Conversion section. Changed definition of the RESOLUTION field of the CVSD Control register (CVCTRL). Changed reset values for ADC registers. Added maximum I/O voltage in Absolute Maximum Ratings section. Added RESET Low minimum DC specification. Added Iccprog DC specification. Changed Vxl2 DC specification. 3/16/04 Updated DC specifications for clock input low voltage, reset input high voltage, and halt current. 5/10/04 Corrected NSIDs for no-lead solder parts. 5/12/04 Moved revision history in front of physical dimensions. Changed back page disclaimers. 6/2/04 Changed AC and DC specifications. 6/15/04 Changed absolute maximum supply voltage to 3.6V. Changed Preliminary to Final. 7/16/04 Added AC timing specifications for ACCESS.bus, external bus, GPIO, Microwire/SPI, and UART. Corrected address of flash data memory in Section 8. www.national.com 244 CP3CN23 31.0 Physical Dimensions (millimeters) unless otherwise noted Figure 120. LQFP-128 Package Figure 121. LQFP-144 Package 245 www.national.com CP3CN23 Connectivity Processor with Bluetooth and Dual CAN Interfaces LIFE SUPPORT POLICY NATIONAL’S PRODUCTS ARE NOT AUTHORIZED FOR USE AS CRITICAL COMPONENTS IN LIFE SUPPORT DEVICES OR SYSTEMS WITHOUT THE EXPRESS WRITTEN APPROVAL OF THE PRESIDENT AND GENERAL COUNSEL OF NATIONAL SEMICONDUCTOR CORPORATION. As used herein: 1. Life support devices or systems are devices or systems which, (a) are intended for surgical implant into the body, or (b) support or sustain life, and whose failure to perform when properly used in accordance with instructions for use provided in the labeling, can be reasonably expected to result in a significant injury to the user. 2. A critical component is any component of a life support device or system whose failure to perform can be reasonably expected to cause the failure of the life support device or system, or to affect its safety or effectiveness. BANNED SUBSTANCE COMPLIANCE National Semiconductor certifies that the products and packing materials meet the provisions of the Customer Products Stewardship Specification (CSP-9-111C2) and the Banned Substances and Materials of Interest Specification (CSP-9111S2) and contain no “Banned Substances” as defined in CSP-9-111S2. National Semiconductor Americas Customer Support Center Email: [email protected] Tel: 1-800-272-9959 www.national.com National Semiconductor Europe Customer Support Center Fax: +49 (0) 180-530 85 86 Email: [email protected] Deutsch Tel: +49 (0) 69 9508 6208 English Tel: +44 (0) 870 24 0 2171 Français Tel: +33 (0) 1 41 91 8790 National Semiconductor Asia Pacific Customer Support Center Email: [email protected] National Semiconductor Japan Customer Support Center Fax: 81-3-5639-7507 Email: [email protected] Tel: 81-3-5639-7560 National does not assume any responsibility for use of any circuitry described, no circuit patent licenses are implied and National reserves the right at any time without notice to change said circuitry and specifications.