PHILIPS SLRC40001T

INTEGRATED CIRCUITS
I•CODE
SL RC400
I•CODE Reader IC
Product Specification
Revision 2.0 Preliminary
Philips
Semiconductors
November 2001
Philips Semiconductors
Product Specification Rev. 2.0 November 2001
I•CODE Reader IC
SL RC400
CONTENTS
1
GENERAL INFORMATION..........................................................................................................6
1.1
Scope .........................................................................................................................................6
1.2
General Description.....................................................................................................................6
1.3
Features .....................................................................................................................................7
1.4
Ordering Information ....................................................................................................................7
2
BLOCK DIAGRAM ......................................................................................................................8
3
PINNING INFORMATION ............................................................................................................9
3.1
Pin Configuration .........................................................................................................................9
3.2
Pin Description.......................................................................................................................... 10
4
PARALLEL INTERFACE........................................................................................................... 12
4.1
Overview of Supported µ-Processor Interfaces ............................................................................ 12
4.2
Automatic µ-Processor Interface Type Detection.......................................................................... 12
4.3
4.3.1
4.3.2
Connection to Different µ-Processor Types ................................................................................. 13
Separated Read/Write Strobe: Intel Type Compatible................................................................... 13
Common Read/Write Strobe: Motorola Type Compatible.............................................................. 14
4.3.3
Common Read/Write Strobe and Hand-Shake Mechanism: EPP.................................................. 15
5
SL RC400 REGISTER SET........................................................................................................ 16
5.1
SL RC400 Registers Overview ................................................................................................... 16
5.1.1
Register Bit Behaviour ............................................................................................................... 18
5.2
5.2.1
Register Description................................................................................................................... 19
Page 0: Command and Status .................................................................................................... 19
5.2.2
5.2.3
5.2.4
Page 1: Control and Status ........................................................................................................ 27
Page 2: Transmitter and Control ................................................................................................. 33
Page 3: Receiver and Decoder Control ....................................................................................... 37
5.2.5
5.2.6
5.2.7
Page 4: RF-Timing and Channel Redundancy............................................................................. 43
Page 5: FIFO, Timer and IRQ- Pin Configuration ......................................................................... 48
Page 7: Test Control .................................................................................................................. 54
5.3
SL RC400 Register Flags Overview............................................................................................ 58
5.4
5.4.1
Modes of Register Addressing.................................................................................................... 61
Paging Mechanism .................................................................................................................... 61
5.4.2
5.4.3
Dedicated Address Bus.............................................................................................................. 61
Multiplexed Address Bus............................................................................................................ 61
6
MEMORY ORGANISATION OF THE E²PROM ........................................................................... 62
6.1
Diagram of the E²PROM Memory Organisation............................................................................ 62
6.2
Product Information Field (Read Only) ........................................................................................ 62
6.3
Register Initialisation Files (Read/Write) ...................................................................................... 63
2
Preliminary
Philips Semiconductors
Product Specification Rev. 2.0 November 2001
I•CODE Reader IC
SL RC400
6.3.1
Start Up Register Initialisation File (Read/Write)........................................................................... 63
6.3.2
6.3.3
Shipment Content of Start Up Register initialisation File ............................................................... 64
Register Initialisation File (Read/Write)........................................................................................ 65
7
FIFO BUFFER........................................................................................................................... 66
7.1
Overview................................................................................................................................... 66
7.2
7.2.1
Accessing the FIFO Buffer.......................................................................................................... 66
Access Rules ............................................................................................................................ 66
7.3
Controlling the FIFO-Buffer......................................................................................................... 66
7.4
Status Information about the FIFO-Buffer.................................................................................... 67
7.5
Register overview FIFO Buffer.................................................................................................... 68
8
INTERRUPT REQUEST SYSTEM .............................................................................................. 69
8.1
8.1.1
Overview................................................................................................................................... 69
Interrupt Sources Overview........................................................................................................ 69
8.2
8.2.1
8.2.2
Implementation of Interrupt Request Handling ............................................................................. 70
Controlling Interrupts and their Status ......................................................................................... 70
Accessing the Interrupt Registers ............................................................................................... 70
8.3
Configuration of Pin IRQ ............................................................................................................ 70
8.4
Register Overview Interrupt Request System .............................................................................. 71
9
TIMER UNIT.............................................................................................................................. 72
9.1
Overview................................................................................................................................... 72
9.2
9.2.1
Implementation of the Timer Unit ................................................................................................ 73
Block Diagram........................................................................................................................... 73
9.2.2
9.2.3
9.2.4
Controlling the Timer Unit........................................................................................................... 74
Timer Unit Clock and Period....................................................................................................... 74
Status of the Timer Unit.............................................................................................................. 75
9.2.5
TimeSlotPeriod.......................................................................................................................... 75
9.3
9.3.1
Usage of the Timer Unit ............................................................................................................. 77
Time-Out- and Watch-Dog-Counter............................................................................................. 77
9.3.2
9.3.3
9.3.4
Stop Watch............................................................................................................................... 77
Programmable One-Shot Timer .................................................................................................. 77
Periodical Trigger ...................................................................................................................... 77
9.4
Register Overview Timer Unit..................................................................................................... 78
10
POWER REDUCTION MODES .................................................................................................. 79
10.1
Hard Power Down...................................................................................................................... 79
10.2
Soft Power Down....................................................................................................................... 79
10.3
Stand By Mode.......................................................................................................................... 80
10.4
Receiver Power Down................................................................................................................ 80
11
START UP PHASE.................................................................................................................... 81
3
Preliminary
Philips Semiconductors
Product Specification Rev. 2.0 November 2001
I•CODE Reader IC
SL RC400
11.1
Hard Power Down Phase........................................................................................................... 81
11.2
Reset Phase.............................................................................................................................. 81
11.3
Initialising Phase........................................................................................................................ 81
11.4
Initialising the Parallel Interface-Type.......................................................................................... 82
12
OSCILLATOR CIRCUITRY........................................................................................................ 83
13
TRANSMITTER PINS TX1 AND TX2.......................................................................................... 84
13.1
Configuration of TX1 and TX2..................................................................................................... 84
13.2
Operating Distance versus Power Consumption .......................................................................... 84
13.2.1 Antenna Driver Output Source Resistance................................................................................... 85
13.3
Changing the Modulation Index .................................................................................................. 87
13.4
Pulse Width............................................................................................................................... 88
14
RECEIVER CIRCUITRY ............................................................................................................ 89
14.1
General..................................................................................................................................... 89
14.2
Block Diagram........................................................................................................................... 89
14.3
Putting the Receiver into Operation............................................................................................. 90
14.3.1 Automatic Clock-Q Calibration.................................................................................................... 90
14.3.2 Amplifier.................................................................................................................................... 91
14.3.3 Correlation Circuitry ................................................................................................................... 92
14.3.4 Evaluation and Digitizer Circuitry ................................................................................................ 92
15
SERIAL SIGNAL SWITCH......................................................................................................... 93
15.1
General..................................................................................................................................... 93
15.2
Block Diagram........................................................................................................................... 93
15.3
Registers Relevant for the Serial Signal Switch............................................................................ 94
16
SL RC400 COMMAND SET ....................................................................................................... 95
16.1
General Description................................................................................................................... 95
16.2
General Behaviour..................................................................................................................... 95
16.3
SL RC400 Commands Overview ................................................................................................ 96
16.3.1 Basic States.............................................................................................................................. 97
16.3.2 StartUp Command 3Fhex ............................................................................................................ 97
16.3.3 Idle Command 00hex ................................................................................................................... 97
16.4
Commands for Label Communication.......................................................................................... 98
16.4.1 Transmit Command 1A hex ........................................................................................................... 98
16.4.2 Receive Command 16hex .......................................................................................................... 100
16.4.3 Transceive Command 1E hex ..................................................................................................... 102
16.4.4 States of the Label Communication........................................................................................... 102
16.4.5 State Diagram for the Label Communication.............................................................................. 103
16.5
Commands to Access the E²PROM .......................................................................................... 104
16.5.1 WriteE2 Command 01hex .......................................................................................................... 104
4
Preliminary
Philips Semiconductors
Product Specification Rev. 2.0 November 2001
I•CODE Reader IC
SL RC400
16.5.2 ReadE2 Command 03hex .......................................................................................................... 106
16.6
Diverse Commands ................................................................................................................. 107
16.6.1 LoadConfig Command 07hex ..................................................................................................... 107
16.6.2 CalcCRC Command 12hex ........................................................................................................ 107
16.7
Error Handling during Command Execution ............................................................................... 108
17
TYPICAL APPLICATION......................................................................................................... 109
17.1
Circuit Diagram........................................................................................................................ 109
17.2
Circuit Description.................................................................................................................... 110
17.2.1 EMC Low Pass Filter ............................................................................................................... 110
17.2.2 Receiving Circuit...................................................................................................................... 110
17.3
Calculation of the Antenna Coil Inductance................................................................................ 110
17.3.1 Impedance Matching for Directly Matched Antennas .................................................................. 111
18
TEST SIGNALS ...................................................................................................................... 112
18.1
General................................................................................................................................... 112
18.2
Measurements Using the Serial Signal Switch........................................................................... 112
18.3
Analog Test-Signals................................................................................................................. 113
18.4
Digital Test-Signals.................................................................................................................. 114
18.5
Examples of Analog- and Digital Test Signals............................................................................ 115
19
ELECTRICAL CHARACTERISTICS......................................................................................... 117
19.1
Absolute Maximum Ratings ...................................................................................................... 117
19.2
Operating Condition Range...................................................................................................... 117
19.3
Current Consumption............................................................................................................... 117
19.4
Pin Characteristics .................................................................................................................. 118
19.4.1 Input Pin Characteristics .......................................................................................................... 118
19.4.2 Digital Output Pin Characteristics ............................................................................................. 119
19.4.3 Antenna Driver Output Pin Characteristics ................................................................................ 119
19.5
AC Electrical Characteristics .................................................................................................... 120
19.5.1 AC Symbols ............................................................................................................................ 120
19.5.2 AC Operating Specification....................................................................................................... 121
19.5.3 Clock Frequency ..................................................................................................................... 124
2
20
E PROM CHARACTERISTICS ................................................................................................ 125
21
PACKAGE OUTLINES ............................................................................................................ 126
21.1
SO32 ...................................................................................................................................... 126
22
TERMS AND ABBREVIATIONS .............................................................................................. 127
23
DEFINITIONS ......................................................................................................................... 128
24
LIFE SUPPORT APPLICATIONS............................................................................................. 128
25
REVISION HISTORY............................................................................................................... 129
5
Preliminary
Philips Semiconductors
Product Specification Rev. 2.0 November 2001
I•CODE Reader IC
1
1.1
SL RC400
GENERAL INFORMATION
Scope
This document describes the functionality of the SL RC400. It includes the functional and electrical
specifications and gives details on how to design-in this device from system and hardware viewpoint.
1.2
General Description
The SL RC400 is member of a new family of highly integrated reader ICs for contactless communication at
13.56 MHz. This new reader IC family utilises an outstanding modulation and demodulation concept
completely integrated for all kinds of passive contactless communication methods and protocols at
13.56 MHz.
The SL RC400 supports all layers of I•CODE1 and ISO 15693.
The internal transmitter part is able to drive an antenna designed for proximity operating distance (up to
100 mm) directly without additional active circuitry.
The receiver part provides a robust and efficient implementation of a demodulation and decoding circuitry for
signals from I•CODE1 and ISO 15693 compatible transponders.
The digital part handles I•CODE1 and ISO 15693 framing and error detection (CRC).
A comfortable parallel interface which can be directly connected to any 8-bit µ-Processor gives high flexibility
for the reader/terminal design.
6
Preliminary
Philips Semiconductors
Product Specification Rev. 2.0 November 2001
I•CODE Reader IC
1.3
SL RC400
Features
•
Highly integrated analog circuitry to demodulate and decode label response
•
Buffered output drivers to connect an antenna with minimum number of external components
•
Proximity operating distance (up to 100 mm)
•
Supports I•CODE1 and ISO 15693
•
Parallel µ-Processor interface with internal address latch and IRQ line
•
Flexible interrupt handling
•
Automatic detection of parallel µC interface type
•
Comfortable 64 byte send and receive FIFO-buffer
•
Hard reset with low power function
•
Power down mode per software
•
Programmable timer
•
Unique serial number
•
User programmable start-up configuration
•
Bit- and byte-oriented framing
•
Independent power supply pins for digital, analog and transmitter part
•
Internal oscillator buffer to connect 13.56 MHz quartz, optimised for low phase jitter
•
Clock frequency filtering
•
3.3 V operation for transmitter (antenna driver) in short range applications
1.4
Ordering Information
Type Number
SL RC400 01T
Package
Name
Description
SO32
Small Outline Package; 32 leads
Table 1-1: SL RC400 Ordering Information
7
Preliminary
Philips Semiconductors
Product Specification Rev. 2.0 November 2001
I•CODE Reader IC
2
SL RC400
BLOCK DIAGRAM
N_WR, N_RD, N_CS
ALE
A0, A1, A2
D0 to D7
FIFO Control
DVDD
Voltage
Monitor
&
Power On
Detect
Parallel Interface Control
(incl. Automatic Interface Detection & Synchronisation)
DVSS
State Machine
64 Byte FIFO
Command Register
Reset
Control
Programable Timer
Power Down
Control
RSTPD
Control Register Bank
Interrupt Control
IRQ
CRC16/CRC8
Generation & Check
EEPROM
8 x 16 Byte EEPROM Access
Control
Parallel/Seriell Converter
Bit Counter
Parity Generation & Check
Frame Generation & Check
Bit Decoding
Bit Coding
Serial Data Switch
SIGOUT
Level Shifters
Amplitude
Rating
Correlation and Bit Decoding
Reference
Voltage
Analog Test
MUX
I-Channel
Amplifier
Q-Channel
Amplifier
I-Channel
Demodulator
Q-Channel
Demodulator
Clock
Generation,
Filtering and
Distribution
Oscillator
Q-Clock
Generation
Power On
Detect
OSCIN
OSCOUT
V+
GND
V+
AUX
AVSS
Transmitter Control
GND
VMID
AVDD
RX
TVSS
8
TX1
TX2
TVDD
Preliminary
Philips Semiconductors
Product Specification Rev. 2.0 November 2001
I•CODE Reader IC
3
3.1
SL RC400
PINNING INFORMATION
Pin Configuration
Pins denoted by bold letters are supplied by AVDD and AVSS. Pins drawn with bold lines are supplied by
TVSS and TVDD. All other pins are supplied by DVDD and DVSS.
OSCIN
1
32
OSCOUT
IRQ
2
31
RSTPD
RFU
3
30
VMID
SIGOUT
4
29
RX
TX1
5
28
AVSS
TVDD
6
27
AUX
TX2
7
26
AVDD
TVSS
8
25
DVDD
NCS
9
24
A2
NWR
10
23
A1
NRD
11
22
A0
DVSS
12
21
ALE
D0
13
20
D7
D1
14
19
D6
D2
15
18
D5
D3
16
17
D4
SL RC400
SO32
Figure 3-1: SL RC400 Pin Configuration for SO32 package
9
Preliminary
Philips Semiconductors
Product Specification Rev. 2.0 November 2001
I•CODE Reader IC
3.2
SL RC400
Pin Description
Pin Types: I...Input;
PIN
SYMBOL
O...Output;
PWR...Power
TYPE
DESCRIPTION
1
OSCIN
I
Crystal Oscillator Input: input to the inverting amplifier of the oscillator.
This pin is also the input for an externally generated clock (fosc = 13.56 MHz).
2
IRQ
O
Interrupt Request: output to signal an interrupt event
3
RFU
I
This Pin should be connected to Ground
4
SIGOUT
O
I•CODE Interface Output: delivers a serial data stream according to I•CODE1 and
5
TX1
O
Transmitter 1: delivers the modulated 13.56 MHz carrier frequenzy
6
TVDD
7
TX2
8
TVSS
PWR
9
NCS
I
Not Chip Select: selects and activates the µ-Processor interface of the SL RC400
NWR
I
Not Write: strobe to write data (applied on D0 to D7) into the SL RC400 register
R/NW
I
Read Not Write: selects if a read or write cycle shall be performed.
nWrite
I
Not Write: selects if a read or write cycle shall be performed
NRD
I
Not Read: strobe to read data from the SL RC400 register (applied on D0 to D7)
NDS
I
Not Data Strobe: strobe for the read and the write cycle
nDStrb
I
Not Data Strobe: strobe for the read and the write cycle
12
DVSS
PWR
13
…
201
D0 to D7
I/O
8 Bit Bi-directional Data Bus
AD0 to AD7
I/O
8 Bit Bi-directional Address and Data Bus
1
10
11
1
PWR
O
ISO 15693
Transmitter Power Supply: supplies the output stage of TX1 and TX2
Transmitter 2: delivers the modulated 13.56 MHz carrier frequenzy
Transmitter Ground: supplies the output stage of TX1 and TX2
Digital Ground
ALE
I
Address Latch Enable: strobe signal to latch AD0 to AD5 into the internal address
latch when HIGH.
AS
I
Address Strobe: strobe signal to latch AD0 to AD5 into the internal address latch
when HIGH.
nAStrb
I
Not Address Strobe: strobe signal to latch AD0 to AD5 into the internal address latch
when LOW.
A0
I
Address Line 1: Bit 0 of register address
nWait
O
Not Wait: signals with LOW that an access-cycle may started and with HIGH that it
may be finished.
23
A1
I
Address Line 1: Bit 1 of register address
24
A2
I
Address Line 2: Bit 2 of register address
25
DVDD
PWR
Digital Power Supply
26
AVDD
PWR
Analog Power Supply
211
221
1
These pins offer different functionality according to the selected µ-Processor interface type. For detailed information
refer to chapter 4.
10
Preliminary
Philips Semiconductors
Product Specification Rev. 2.0 November 2001
I•CODE Reader IC
SL RC400
PIN Description (continued)
PIN
SYMBOL
TYPE
DESCRIPTION
Auxiliary Output: This pin delivers analog test signals. The signal delivered on this
output may be selected by means of the TestAnaOutSel Register.
27
AUX
O
28
AVSS
PWR
29
RX
30
VMID
31
RSTPD
I
Reset and Power Down: When HIGH, internal current sinks are switched off, the
oscillator is inhibited, and the input pads are disconnected from the outside world.
With a negative edge on this pin the internal reset phase starts.
32
OSCOUT
O
Crystal Oscillator Output: Output of the inverting amplifier of the oscillator.
I
PWR
Analog Ground
Receiver Input: Input pin for the labels response, which is the load modulated
13.56 MHz carrier frequenzy, that is coupled out from the antenna circuit.
Internal Reference Voltage: This pin delivers the internal reference voltage.
Note: It has to be supported by means of a 100 nF block capacitor.
Table 3-1: SL RC400 Pin Description
11
Preliminary
Philips Semiconductors
Product Specification Rev. 2.0 November 2001
I•CODE Reader IC
4
SL RC400
PARALLEL INTERFACE
4.1
Overview of Supported µ-Processor Interfaces
The SL RC400 supports direct interfacing of various µ-Processor. Alternatively the Enhanced Parallel Port
(EPP) of personal computers can be connected directly.
The following table shows the parallel interface signals supported by the SL RC400:
Bus Control Signals
Separated Read and Write
Strobes
Common Read and Write
Strobe
Bus
Separated Address and Data Bus
Multiplexed Address and Data Bus
control
NRD, NWR, NCS
NRD, NWR, NCS, ALE
address
A0, A1, A2
AD0, AD1, AD2, (AD3, AD4, AD5)
data
D0 … D7
AD0 … AD7
control
R/NW, NDS, NCS
R/NW, NDS, NCS, AS
address
A0, A1, A2
AD0, AD1, AD2, (AD3, AD4, AD5)
data
D0 … D7
AD0 … AD7
control
Common Read and Write
Strobe with Handshake
nWrite, nDStrb, NCS, nAStrb, nWait
address
-
AD0, AD1, AD2, (AD3, AD4, AD5)
(EPP)
data
AD0 … AD7
Table 4-1: Supported µ-Processor Interface Signals
4.2
Automatic µ-Processor Interface Type Detection
After each Power-On or Hard Reset, the SL RC400 also resets its parallel µ-Processor interface mode and
checks the current µ-Processor interface type.
The SL RC400 identifies the µ-Processor interface by means of the logic levels on the control pins after the
Reset Phase. This is done by a combination of fixed pin connections (see below) and a dedicated
initialisation routine (see 11.4).
12
Preliminary
Philips Semiconductors
Product Specification Rev. 2.0 November 2001
I•CODE Reader IC
4.3
SL RC400
Connection to Different µ-Processor Types
The connection to different µ-Processor types is shown in the following table:
Parallel Interface Type
Separated Read/Write Strobe
Common Read/Write Strobe
SL RC400
Dedicated
Address Bus
Multiplexed
Address Bus
Dedicated
Address Bus
Multiplexed
Address Bus
Multiplexed
Address Bus with
Handshake
ALE
HIGH
ALE
HIGH
AS
nAStrb
A2
A2
LOW
A2
LOW
HIGH
A1
A1
HIGH
A1
HIGH
HIGH
A0
A0
HIGH
A0
LOW
nWait
NRD
NRD
NRD
NDS
NDS
nDStrb
NWR
NWR
NWR
R/NW
R/NW
nWrite
NCS
NCS
NCS
NCS
NCS
LOW
D7 ... D0
D7 ... D0
AD7 ... AD0
D7 ... D0
AD7 ... AD0
AD7 ... AD0
Table 4-2: Connection Scheme for Detecting the Parallel Interface Type
4.3.1
SEPARATED READ/WRITE STROBE: INTEL TYPE COMPATIBLE
SL RC400
Address Bus (A3...An)
Address
Decoder
SL RC400
NCS
Non Multiplexed Address
Address
Decoder
NCS
LOW
Address Bus (A0...A2)
A0...A2
HIGH
HIGH
Data Bus (D0...D7)
D0...D7
Multiplexed Address/Data (AD0...AD7)
HIGH
Address Latch Enable (ALE)
ALE
Read Strobe (NRD)
Write Strobe (NWR)
Read Strobe (NRD)
NRD
Write Strobe (NWR)
NWR
A2
A1
A0
D0...D7
ALE
NRD
NWR
Figure 4-1: Connection to µ-Processors with Separated Read/Write Strobes
For timing specification refer to chapter 19.5.2.1.
13
Preliminary
Philips Semiconductors
Product Specification Rev. 2.0 November 2001
I•CODE Reader IC
4.3.2
SL RC400
COMMON READ/WRITE STROBE: MOTOROLA TYPE COMPATIBLE
SL RC400
Address Bus (A3...An)
Address
Decoder
SL RC400
NCS
Non Multiplexed Address
Address
Decoder
LOW
Address Bus (A0...A2)
Data Bus (D0...D7)
HIGH
Data Strobe (NDS)
Read/Write (R/NW)
HIGH
A0...A2
LOW
D0...D7
Multiplexed Address/Data (AD0...AD7)
Address Strobe (AS)
ALE
Data Strobe (NDS)
NRD
Read/Write (R/NW)
NWR
NCS
A2
A1
A0
D0...D7
ALE
NRD
NWR
Figure 4-2: Connection to µ-Processors with Common Read/Write Strobes
For timing specification refer to chapter 19.5.2.2.
14
Preliminary
Philips Semiconductors
Product Specification Rev. 2.0 November 2001
I•CODE Reader IC
4.3.3
SL RC400
COMMON READ/WRITE STROBE AND HAND-SHAKE MECHANISM: EPP
SL RC400
LOW
NCS
HIGH
A2
A1
A0
HIGH
nWait
D0...D7
Multiplexed Address/Data (AD1...AD8)
Address Strobe (nAStrb)
ALE
Data Strobe (nDStrb)
NRD
Read/Write (nWrite)
NWR
Figure 4-3: Connection to µ-Processors with Common Read/Write Strobes and Hand-Shake
For timing specification refer to chapter 19.5.2.3.
Remarks for EPP:
Although in the standard for the EPP no chip select signal is defined, the N_CS of the SL RC400 allows
inhibiting the nDStrb signal. If not used, it shall be connected to DVSS.
After each Power-On or Hard Reset the nWait signal (delivered at pin A0) is high impedance. nWait will be
defined at the first negative edge applied to nAStrb after the Reset Phase.
The SL RC400 does not support Read Address Cycle.
15
Preliminary
Philips Semiconductors
Product Specification Rev. 2.0 November 2001
I•CODE Reader IC
5
SL RC400
SL RC400 REGISTER SET
SL RC400 Registers Overview
Addresshex
Register Name
Function
0
Page
selects the register page
1
Command
starts (and stops) the command execution
2
FIFOData
in- and output of 64 byte FIFO buffer
3
PrimaryStatus
status flags of the receiver and transmitter and of the FIFO buffer
4
FIFOLength
number of bytes buffered in the FIFO
5
SecondaryStatus
diverse status flags
6
InterruptEn
control bits to enable and disable passing of interrupt requests
7
InterruptRq
interrupt request flags
8
Page
selects the register page
9
Control
diverse control flags e.g.: timer, power saving
A
ErrorFlag
error flags showing the error status of the last command executed
B
Collpos
bit position of the first bit collision detected on the RF-interface
C
TimerValue
actual value of the timer
D
CRCResultLSB
LSB of the CRC-Coprocessor register
E
CRCResultMSB
MSB of the CRC-Coprocessor register
F
PreSet0F
these values shall not be changed
10
Page
selects the register page
11
TxControl
controls the logical behaviour of the antenna driver pins TX1 and TX2
12
CwConductance
selects the conductance of the antenna driver pins TX1 and TX2
13
ModConductance
selects the conductance of the antenna driver pins TX1 and TX2 during
modulation
14
CoderControl
Selects the bit coding mode and the framing during transmission
15
ModWidth
selects the width of the modulation pulse
16
ModWidthSOF
selects the width of the modulation pulse for SOF (I•CODE Fast-Mode)
17
PreSet17
these values shall not be changed
18
Page
selects the register page
19
RxControl1
controls receiver behaviour
1A
DecoderControl
controls decoder behaviour
1B
BitPhase
selects the bit-phase between transmitter and receiver clock
1C
RxThreshold
selects thresholds for the bit decoder
1D
PreSet1D
these values shall not be changed
1E
RxControl2
controls decoder behaviour and defines the input source for the receiver
1F
ClockQControl
controls clock generation for the 90° phase shifted Q-channel clock
Page 3:
Receiver and Decoder Control
Page 2: Transmitter and Coder
Control
Page 1: Control and Status
Page
Page 0: Command and Status
5.1
16
Preliminary
Philips Semiconductors
Product Specification Rev. 2.0 November 2001
I•CODE Reader IC
SL RC400
SL RC400 Register Set (continued)
Page 7:
Test Control
Page 6:
RFU
Page 5: FIFO, Timer and IRQPin Configuration
Page 4: RF-Timing and Channel
Redundancy
Page
Addresshex
Register Name
Function
20
Page
selects the register page
21
RxWait
selects the time interval after transmission, before receiver starts
22
ChannelRedundancy
selects the kind and mode of checking the data integrity on the RFchannel
23
CRCPresetLSB
LSB of the pre-set value for the CRC register
24
CRCPresetMSB
MSB of the pre-set value for the CRC register
25
TimeSlotPeriod
selects the time between automatically mitted Frames see chapter 9.2.5
26
SIGOUTSelect
selects internal signal applied to pin SIGOUT
includes the MSB of value TimeSlotPeriod see register 0x25
27
PreSet27
these values shall not be changed
28
Page
Selects the register page
29
FIFOLevel
defines level for FIFO over– and underflow warning
2A
TimerClock
selects the divider for the timer clock
2B
TimerControl
selects start and stop conditions for the timer
2C
TimerReload
defines the pre-set value for the timer
2D
IrqPinConfig
configures the output stage of pin IRq
2E
PreSet2E
these values shall not be changed
2F
PreSet2F
these values shall not be changed
30
Page
selects the register page
31
RFU
reserved for future use
32
RFU
reserved for future use
33
RFU
reserved for future use
34
RFU
reserved for future use
35
RFU
reserved for future use
36
RFU
reserved for future use
37
RFU
reserved for future use
38
Page
selects the register page
39
RFU
reserved for future use
3A
TestAnaSelect
selects analog test mode
3B
PreSet3B
these values shall not be changed
3C
PreSet3C
these values shall not be changed
3D
TestDigiSelect
selects digital test mode
3E
RFU
reserved for future use
3F
RFU
reserved for future use
Table 5-1: SL RC400 Register Overview
17
Preliminary
Philips Semiconductors
Product Specification Rev. 2.0 November 2001
I•CODE Reader IC
5.1.1
SL RC400
REGISTER BIT BEHAVIOUR
Bits and flags for different registers behave differently, depending on their functions. In principle bits with
same behaviour are grouped in common registers.
Abbreviation
Behaviour
Description
read and
write
These bits can be written and read by the µ-Processor. Since they are used
only for control means, there content is not influenced by internal state
machines, e.g. the TimerReload-Register may be written and read by the µProcessor. It will also be read by internal state machines, but never changed by
them.
dy
dynamic
These bits can be written and read by the µ-Processor. Nevertheless, they may
also be written automatically by internal state machines, e.g. the CommandRegister changes its value automatically after the execution of the actual
command.
r
read only
These registers hold flags, which value is determined by internal states only,
e.g. the ErrorFlag-Register can not be written from external but shows internal
states.
w
write only
These registers are used for control means only. They may be written by the µProcessor but can not be read. Reading these registers returns an undefined
value, e.g. the TestAnaSelect-Register is used to determine the signal on pin
AUX, but it is not possible to read its content.
r/w
Table 5-2: Behaviour of Register Bits and its Designation
18
Preliminary
Philips Semiconductors
Product Specification Rev. 2.0 November 2001
I•CODE Reader IC
5.2
SL RC400
Register Description
5.2.1
PAGE 0: COMMAND AND STATUS
5.2.1.1
Page Register
Selects the register page.
Name: Page
Access
Rights
Address: 0x00, 0x08, 0x10, 0x18,
0x20, 0x28, 0x30, 0x38
7
6
5
4
3
UsePage
Select
0
0
0
0
r/w
r/w
r/w
r/w
r/w
Reset value: 10000000, 0x80
2
1
0
PageSelect
r/w
r/w
r/w
Description of the bits
Bit
Symbol
Function
7
UsePageSelect
If set to 1, the value of PageSelect is used as register address A5, A4, and A3.
The LSBbits of the register address are defined by the address pins or the internal
address latch, respectively.
If set to 0, the whole content of the internal address latch defines the register
address. The address pins are used as described in Table 4-2.
6-3
0000
2-0
PageSelect
Reserved for future use.
The value of PageSelect is used only if UsePageSelect is set to 1. In this case, it
specifies the register page (which is A5, A4, and A3 of the register address).
19
Preliminary
Philips Semiconductors
Product Specification Rev. 2.0 November 2001
I•CODE Reader IC
5.2.1.2
SL RC400
Command Register
Starts and stops the command execution.
Name: Command
Address: 0x01
7
6
IFDetect
Busy
0
r
r
Access
Rights
5
4
Reset value:X0000000, 0xX0
3
2
1
0
dy
dy
dy
Command
dy
dy
dy
Description of the bits
Bit
Symbol
7
IFDetectBusy
6
0
5-0
Command
Function
Shows the status of Interface Detection Logic:
Set to 0 means ‘Interface Detection finished successfully’,
Set to 1 signs ‘Interface Detection Ongoing’.
Reserved for future use.
Activates a command according the Command Code.
Reading this register shows, which command is actually executed.
See chapter 16. SL RC400 Command Set.
20
Preliminary
Philips Semiconductors
Product Specification Rev. 2.0 November 2001
I•CODE Reader IC
5.2.1.3
SL RC400
FIFOData Register
In- and output of the 64 byte FIFO buffer
Name: FIFOData
7
Address: 0x02
6
5
Reset value: XXXXXXXX, 0xXX
4
3
2
1
0
dy
dy
dy
dy
FIFOData
Access
Rights
dy
dy
dy
dy
Description of the bits
Bit
Symbol
7-0
FIFOData
Function
Data Input and Output Port for the internal 64 byte FIFO buffer. The FIFO buffer
acts as parallel in/parallel out converter for all data stream in- and outputs.
21
Preliminary
Philips Semiconductors
Product Specification Rev. 2.0 November 2001
I•CODE Reader IC
5.2.1.4
SL RC400
PrimaryStatus Register
Status flags of the receiver, transmitter and the FIFO buffer.
Name: PrimaryStatus
7
Address: 0x03
6
0
Access
Rights
r
5
Reset value: 00000001, 0x01
4
ModemState
r
r
r
3
2
1
0
IRq
Err
HiAlert
LoAlert
r
r
r
r
Description of the bits
Bit
Symbol
7
0
6-4
ModemState
Function
Reserved for future use.
ModemState shows the state of the transmitter and receiver state machines.
State
Name of State
Description
000
Idle
Neither the transmitter nor the receiver is in operation,
since none of them is started or
since none of them has got input data.
001
TxSOF
Transmitting the ‘Start Of Frame’ Pattern.
010
TxData
Transmitting data from the FIFO buffer (or redundancy
check bits).
011
TxEOF
Transmitting the ‘End Of Frame’ Pattern.
100
GoToRx1
Mean-State passed, when receiver starts.
GoToRx2
Mean-State passed, when receiver finishes.
101
PrepareRx
Waiting until the time period selected in the RxWait
Register has expired.
110
AwaitingRx
Receiver activated; Awaiting an input signal at pin Rx.
111
Receiving
Receiving data.
3
IRq
This bit shows, if any interrupt source requests attention (with respect to the
setting of the interrupt enable flags in the InterruptEn Register).
2
Err
This bit is set to 1, if any error flag in the ErrorFlag Register is set.
1
HiAlert
Is set to 1, when the number of bytes stored in the FIFO buffer fulfil the following
equation: HiAlert = (64 − FIFOLength) ≤ WaterLevel
Example:
0
LoAlert
FIFOLength=60, WaterLevel=4
⇒ HiAlert =1
FIFOLength=59, WaterLevel=4
⇒ HiAlert =0
Is set to 1, when the number of bytes stored in the FIFO buffer fulfil the following
equation: LoAlert = FIFOLength ≤ WaterLevel
Example:
FIFOLength=4, WaterLevel=4
⇒ LoAlert =1
FIFOLength=5, WaterLevel=4
⇒ LoAlert =0
22
Preliminary
Philips Semiconductors
Product Specification Rev. 2.0 November 2001
I•CODE Reader IC
5.2.1.5
SL RC400
FIFOLength Register
Number of bytes buffered in the FIFO.
Name: FIFOLength
7
Address: 0x04
6
5
Reset value: 00000000, 0x00
4
0
Access
Rights
r
3
2
1
0
r
r
r
FIFOLength
r
r
r
r
Description of the bits
Bit
Symbol
7
0
6-0
FIFOLength
Function
Reserved for future use.
Indicates the number of bytes stored in the FIFO buffer. Writing to the FIFOData
Register increments, reading decrements FIFOLength.
23
Preliminary
Philips Semiconductors
Product Specification Rev. 2.0 November 2001
I•CODE Reader IC
5.2.1.6
SL RC400
SecondaryStatus Register
Diverse Status flags.
Name: SecondaryStatus
Access
Rights
Address: 0x05
Reset value: 01100000, 0x60
7
6
5
4
3
TRunning
E2Ready
CRCReady
0
0
r
r
r
r
r
2
1
0
RxLastBits
r
r
r
Description of the bits
Bit
Symbol
Function
7
TRunning
If set to 1, the SL RC400’s timer unit is running, e.g. the counter will decrement
the Timer Value Register with the next timer clock.
6
E2Ready
If set to 1, the SL RC 400 has finished programming the E PROM.
5
CRCReady
4-3
00
2-0
RxLastBits
2
If set to 1, the SL RC400 has finished calculating the CRC.
Reserved for future use.
Show the number of valid bits in the last received byte. If zero, the whole byte is
valid.
24
Preliminary
Philips Semiconductors
Product Specification Rev. 2.0 November 2001
I•CODE Reader IC
5.2.1.7
SL RC400
InterrupEn Register
Control bits to enable and disable passing of interrupt requests.
Name: InterruptEn
Access
Rights
Address: 0x06
Reset value: 00000000, 0x00
7
6
5
4
3
2
1
0
SetIEn
0
TimerIEn
TxIEn
RxIEn
IdleIEn
HiAlertIEn
LoAlertIEn
w
r/w
r/w
r/w
r/w
r/w
r/w
r/w
Description of the bits
Bit
Symbol
Function
7
SetIEn
6
0
5
TimerIEn
4
TxIEn
Allows the transmitter interrupt request (indicated by bit TxIRq) to be propagated
to pin IRQ. This bit can not be set or cleared directly but only by means of bit
SetIEn.
3
RxIEn
Allows the receiver interrupt request (indicated by bit RxIRq) to be propagated to
pin IRQ. This bit can not be set or cleared directly but only by means of bit SetIEn.
2
IdleIEn
Allows the idle interrupt request (indicated by bit IdleIRq) to be propagated to pin
IRQ. This bit can not be set or cleared directly but only by means of bit SetIEn.
1
HiAlertIEn
Allows the high alert interrupt request (indicated by bit HiAlertIRq) to be
propagated to pin IRQ. This bit can not be set or cleared directly but only by
means of bit SetIEn.
0
LoAlertIEn
Allows the low alert interrupt request (indicated by bit LoAlertIRq) to be
propagated to pin IRQ. This bit can not be set or cleared directly but only by
means of bit SetIEn.
Set to 1 SetIEn defines that the marked bits in the InterruptEn Register are set,
Set to 0 clears the marked bits.
Reserved for future use.
Allows the timer interrupt request (indicated by bit TimerIRq) to be propagated to
pin IRQ. This bit can not be set or cleared directly but only by means of bit SetIEn.
25
Preliminary
Philips Semiconductors
Product Specification Rev. 2.0 November 2001
I•CODE Reader IC
5.2.1.8
SL RC400
InterruptRq Register
Interrupt request flags.
Name: InterruptRq
Access
Rights
Address: 0x07
Reset value: 00000000, 0x00
7
6
5
4
3
2
1
0
SetIRq
0
TimerIRq
TxIRq
RxIRq
IdleIRq
HiAlertIRq
LoAlertIRq
w
r/w
dy
dy
dy
dy
dy
dy
Description of the bits
Bit
Symbol
7
SetIRq
6
0
5
TimerIRq
4
TxIRq
Function
Set to 1 SetIRq defines that the marked bits in the InterruptRq Register are set.
Set to 0 defines, that the marked bits in the InterruptRq Register are cleared.
Reserved for future use.
Set to 1, when the timer decrements the TimerValue Register to zero.
Set to 1, when one of the following events occurs:
Transceive Command: All data transmitted.
CalcCRC Command: All data is processed.
WriteE2 Command: All data is programmed.
3
RxIRq
This bit is set to 1, when the receiver terminates.
2
IdleIRq
This bit is set to 1, when a command terminates by itself e.g. when the Command
Register changes its value from any command to the Idle Command.
If an unknown command is started bit IdleIRq is set.
Starting the Idle Command by the µ-Processor does not set bit IdleIRq.
1
HiAlertIRq
This bit is set to 1, when bit HiAlert is set. In opposite to HiAlert, HiAlertIRq stores
this event and can only be reset by means of bit SetIRq.
0
LoAlertIRq
This bit is set to 1, when bit LoAlert is set. In opposite to LoAlert, LoAlertIRq
stores this event and can only be reset by means of bit SetIRq.
26
Preliminary
Philips Semiconductors
Product Specification Rev. 2.0 November 2001
I•CODE Reader IC
5.2.2
SL RC400
PAGE 1: CONTROL AND STATUS
5.2.2.1
Page Register
Selects the register page. See 5.2.1.1 Page register.
5.2.2.2
Control Register
Diverse control flags, e.g. : timer, power saving
Name: Control
Access
Rights
Address: 0x09
Reset value: 00000000, 0x00
7
6
5
4
3
2
1
0
0
0
StandBy
PowerDown
0
TStopNow
TStartNow
FlushFIFO
r/w
r/w
dy
dy
dy
w
w
w
Description of the bits
Bit
Symbol
Function
7-6
00
5
StandBy
Setting this bit to 1 enters the Soft PowerDown Mode. This means, internal
current consuming blocks switch off, the oscillator keeps running.
4
PowerDown
Setting this bit to 1 enters the Soft PowerDown Mode. This means, internal
current consuming blocks switch off including the oscillator.
3
0
2
TStopNow
Setting this bit to 1 starts the timer immediately.
Reading this bit will always return 0.
1
TStartNow
Setting this bit to 1 stops the timer immediately.
Reading this bit will always return 0.
0
FlushFIFO
Setting this bit to 1clears the internal FIFO-buffer’s read- and write-pointer
(FIFOLength becomes 0) and the flag FIFOOvfl immediately.
Reading this bit will always return 0.
Reserved for future use
Reserved for future use
27
Preliminary
Philips Semiconductors
Product Specification Rev. 2.0 November 2001
I•CODE Reader IC
5.2.2.3
SL RC400
ErrorFlag Register
Error flags showing the error status of the last executed command.
Name: ErrorFlag
Access
Rights
Address: 0x0A
Reset value: 00000000, 0x00
7
6
5
4
3
2
1
0
0
0
AccessErr
FIFOOvfl
CRCErr
FramingErr
0
CollErr
r
r
r
r
r
r
r
r
Description of the bits
Bit
Symbol
Function
7-6
0
5
AccessErr
4
FIFOOvfl
This bit is set to 1, if the µ-Processor or a SL RC400’s internal state machine
(e.g. receiver) tries to write data into the FIFO buffer although the FIFO buffer is
already full.
3
CRCErr
This bit is set to 1, if RxCRCEn is set and the CRC fails. It is cleared to 0
automatically at receiver start phase during the state PrepareRx.
2
FramingErr
1
0
0
CollErr
Reserved for future use.
This bit is set to 1, if the access rights to the E²PROM are violated.
This bit is set to 0 starting an E²PROM related command.
This bit is set to 1, if the SOF is incorrect. It is cleared automatically at receiver
start (that is during the state PrepareRx).
RFU
This bit is set to 1, if a bit-collision is detected. It is cleared automatically at
receiver start (that is during the state PrepareRx).
28
Preliminary
Philips Semiconductors
Product Specification Rev. 2.0 November 2001
I•CODE Reader IC
5.2.2.4
SL RC400
CollPos Register
Bit position of the first bit collision detected on the RF- interface.
Name: CollPos
Address: 0x0B
7
6
5
Reset value: 00000000, 0x00
4
3
2
1
0
r
r
r
r
CollPos
Access
Rights
r
r
r
r
Description of the bits
Bit
Symbol
7-0
CollPos
Function
This register shows the bit position of the first detected collision in a received
frame.
Example:
0x00 indicates a bit collision in the start bit
st
0x01 indicates a bit collision in the 1 bit
th
0x08 indicates a bit collision in the 8 bit
29
Preliminary
Philips Semiconductors
Product Specification Rev. 2.0 November 2001
I•CODE Reader IC
5.2.2.5
SL RC400
TimerValue Register
Actual value of the timer
Name: TimerValue
7
Address:0x0C
6
5
Reset value: XXXXXXXX, 0xXX
4
3
2
1
0
r
r
r
r
TimerValue
Access
Rights
r
r
r
r
Description of the bits
Bit
Symbol
7-0
TimerValue
Function
This register shows the actual value of the timer counter.
30
Preliminary
Philips Semiconductors
Product Specification Rev. 2.0 November 2001
I•CODE Reader IC
5.2.2.6
SL RC400
CRCResultLSB Register
LSB of the CRC-Coprocessor register.
Name: CRCResultLSB
7
Address: 0x0D
6
5
Reset value: XXXXXXXX, 0xXX
4
3
2
1
0
r
r
r
CRCResultLSB
Access
Rights
r
r
r
r
r
Description of the bits
Bit
Symbol
7-0
CRCResultLSB
Function
This register shows the actual value of the least significant byte of the CRC
register. It is valid only if bit CRCReady is set to 1.
31
Preliminary
Philips Semiconductors
Product Specification Rev. 2.0 November 2001
I•CODE Reader IC
5.2.2.7
SL RC400
CRCResultMSB Register
MSB of the CRC-Coprocessor register.
Name: CRCResultMSB
Address: 0x0E
7
6
5
Reset value: XXXXXXXX, 0xXX
4
3
2
1
0
r
r
r
CRCResultMSB
Access
Rights
r
r
r
r
r
Description of the bits
Bit
Symbol
7-0
CRCResultMSB
Function
This register shows the actual value of the most significant byte of the CRC
register. It is valid only if bit CRCReady is set to 1.
For 8-bit CRC calculation the registers value is undefined.
5.2.2.8
PreSet0F Register
Name: PreSet0F
Access
Rights
Address: 0x0F
Reset value: 00000000, 0x00
7
6
5
4
3
2
1
0
0
0
0
0
0
0
0
0
r/w
r/w
r/w
r/w
r/w
r/w
r/w
r/w
Note: These values shall not be changed !
32
Preliminary
Philips Semiconductors
Product Specification Rev. 2.0 November 2001
I•CODE Reader IC
5.2.3
SL RC400
PAGE 2: TRANSMITTER AND CONTROL
5.2.3.1
Page Register
Selects the register page. See 5.2.1.1 Page register.
5.2.3.2
TxControl Register
Controls the logical behaviour of the antenna pin TX1 and TX2
Name: TxControl
7
0
Access
Rights
r/w
Address: 0x11
6
5
ModulatorSource
r/w
r/w
Reset value: 01001000, 0x48
4
3
2
1
0
Force100
ASK
TX2Inv
TX2Cw
TX2RFEn
TX1RFEn
r/w
r/w
r/w
r/w
r/w
Description of the bits
Bit
Symbol
7
0
6-5
Modulator
Source
Function
This value shall not be changed
Selects the source for the modulator input:
00:
LOW
01:
HIGH
10:
Internal Coder
11:
RFU
4
Force100ASK
Set to 1, forces a 100% ASK Modulation independent of the setting in the
ModConductance Register.
3
TX2Inv
Set to 1, the output signal on pin TX2 will deliver an inverted 13.56 MHz carrier
frequenzy.
2
TX2Cw
Set to 1, the output signal on pin TX2 will deliver continuously the un-modulated
13.56 MHz carrier frequenzy.
Setting TX2Cw to 0 enables modulation of the 13.56 MHz carrier frequenzy.
1
TX2RFEn
Set to 1, the output signal on pin TX2 will deliver the 13.56 MHz carrier frequency
modulated by the transmission data.
If TX2RFEn is 0, TX2 drives a constant output level. See chapter 13.
0
TX1RFEn
Set to 1, the output signal on pin TX1 will deliver the 13.56 MHz carrier frequency
modulated by the transmission data.
If TX1RFEn is 0, TX1 drives a constant output level. See chapter 13.
33
Preliminary
Philips Semiconductors
Product Specification Rev. 2.0 November 2001
I•CODE Reader IC
5.2.3.3
SL RC400
CwConductance Register
Selects the conductance of the antenna driver pins TX1 and TX2.
Name: CwConductance
Access
Rights
Address: 0x12
7
6
0
0
r/w
r/w
5
Reset value: 00111111, 0x3F
4
3
2
1
0
r/w
r/w
r/w
GsCfgCW
r/w
r/w
r/w
Description of the bits
Bit
Symbol
7-6
00
5-0
GsCfgCW
Function
These values shall not be changed
The value of this register defines the conductance of the output driver. This may
be used to regulate the output power and subsequently current consumption and
operating distance.
For detailed information about GsCfgCW see 13.2.1
5.2.3.4
ModConductance Register
Name: ModConductance
Access
Rights
Address: 0x13
7
6
0
0
r/w
r/w
5
Reset value: 00000101, 0x05
4
3
2
1
0
r/w
r/w
r/w
GsCfgMod
r/w
r/w
r/w
Description of the bits
Bit
Symbol
7-6
00
5-0
GsCfgMod
Function
These values shall not be changed
The value of this register defines the conductance of the output driver for the time
of modulation. This may be used to regulate the modulation index.
For detailed information about GsCfgMod see 13.3
34
Preliminary
Philips Semiconductors
Product Specification Rev. 2.0 November 2001
I•CODE Reader IC
5.2.3.5
SL RC400
CoderControl Register
Name: CoderControl
Access
Rights
Address:0x14
7
6
SendOne
Pulse
0
r/w
r/w
5
Reset value: 00101100, 0x2C
4
3
2
CoderRate
r/w
r/w
1
0
TxCoding
r/w
r/w
r/w
r/w
Description of the bits
Bit
Symbol
7
SendOnePulse
6
0
5-3
CoderRate
Function
Set to 1, forces to generate only one Mudulation (for ISO 15693 only). This is
used to switch to the next TimeSlot if the Inventory command is used.
This bit is not cleared automatically, it has to be re-set to 0 by the user.
These values shall not be changed
This register defines the clock rate for Coder Circuit
000:
001:
010:
011:
100:
101:
110:
111:
2-0
TxCoding
RFU
RFU
RFU
RFU
RFU
For I?CODE1 standard mode and ISO 15693 (~52.97kHz)
For I?CODE1 fast mode (~26.48kHz)
RFU
This register defines the bit coding Mode and Framing during Transmission
000:
001:
010:
011:
100:
101:
110:
111:
RFU
RFU
RFU
RFU
For I?CODE1 standard mode (1 out of 256 coding)
For I?CODE1 fast mode (RZ coding)
For ISO 15693 standard mode (1 out of 256 coding)
For ISO 15693 fast mode (1 out of 4 coding)
35
Preliminary
Philips Semiconductors
Product Specification Rev. 2.0 November 2001
I•CODE Reader IC
5.2.3.6
SL RC400
ModWidth Register
selects the width of the modulation pulse.
Name: ModWidth
7
Address: 0x15
6
5
Reset value: 00111111, 0x3F
4
3
2
1
0
r/w
r/w
r/w
r/w
ModWidth
Access
Rights
r/w
r/w
r/w
r/w
Description of the bits
Bit
Symbol
7-0
ModWidth
Function
This register defines the width of the modulation pulse according to
Tmod = 2⋅(ModWidth +1) / fc (fc = Oscillator clock 13.56 MHz).
Preset for I•CODE1 (Fast and Standard Mode) and ISO 15693 is 0x3F
(Modulation width: 9.44µs).
5.2.3.7
ModWidthSOF Register
Name: ModWidthSOF
7
Address: 0x16
6
5
Reset value: 00111111, 0x3F
4
3
2
1
0
r/w
r/w
r/w
ModWidthSOF
Access
Rights
r/w
r/w
r/w
r/w
r/w
Description of the bits
Bit
Symbol
7-0
ModWidthSOF
Function
This register defines the width of the modulation pulse for SOF
Tmod = 2⋅(ModWidth +1) / fc .
Register setting:
I•CODE1 Standard Mode: 0x3F (Modulation width SOF: 9.44µs).
I•CODE1 Fast Mode: 0x73 (Modulation width SOF: 18.88µs).
ISO 15693: 0x3F (Modulation width SOF: 9.44µs).
36
Preliminary
Philips Semiconductors
Product Specification Rev. 2.0 November 2001
I•CODE Reader IC
5.2.3.8
SL RC400
PreSet17 Register
Name: PreSet17
Access
Rights
Address: 0x17
Reset value: 00000000, 0x00
7
6
5
4
3
2
1
0
0
0
0
0
0
0
0
0
r/w
r/w
r/w
r/w
r/w
r/w
r/w
r/w
Note: These values shall not be changed !
5.2.4
PAGE 3: RECEIVER AND DECODER CONTROL
5.2.4.1
Page Register
Selects the register page. See 5.2.1.1 Page Register.
5.2.4.2
RxControl1 Register
controls receiver behaviour.
Name: RxControl1
Access
Rights
Address: 0x19
Reset value: 10001011, 0x8B
7
6
5
4
3
2
1
0
0
0
1
0
r/w
r/w
r/w
r/w
r/w
r/w
1
0
Gain
r/w
r/w
Description of the bits
Bit
Symbol
7-2
100010
1-0
Gain
Function
These values shall not be changed
This register defines the receivers signal voltage gain factor:
00: 27 dB
01: 30 dB
10: 38 dB
11: 42 dB
37
Preliminary
Philips Semiconductors
Product Specification Rev. 2.0 November 2001
I•CODE Reader IC
5.2.4.3
SL RC400
DecoderControl Register
controls decoder behaviour.
Name: DecoderControl
Access
Rights
Address: 0x1A
7
6
5
0
Rx
Multiple
ZeroAfter
Coll
r/w
r/w
r/w
Reset value: 00000000, 0x00
4
3
RxFraming
r/w
r/w
2
1
0
RxInvert
0
0
r/w
r/w
r/w
Description of the bits
Bit
Symbol
7
0
6
RxMultiple
5
ZeroAfterColl
4-3
RxFraming
2
RxInvert
1-0
00
Function
These values shall not be changed
If set to 0, the receiver is deactivated after receiving the Datastream.
If set to 1, it is possible to receive more than one Frame.
If set to 1, any bits received after a bit-collision are masked to zero. This eases
resolving the anti-collision procedure defined in the standard ISO 15693.
Selects the receiving frame type
00 for I•CODE1
01 RFU
10 ISO 15693
11 RFU
If set to 0, a modulation at the first half bit results a logic 1 (according I• CODE1)
If set to 1, a modulation at the first half bit results a logic 0 (according ISO15693)
These values shall not be changed
38
Preliminary
Philips Semiconductors
Product Specification Rev. 2.0 November 2001
I•CODE Reader IC
5.2.4.4
SL RC400
BitPhase Register
selects the bit-phase between transmitter and receiver clock.
Name: BitPhase
Address: 0x1B
7
6
5
Reset value: 01010100, 0x54
4
3
2
1
0
r/w
r/w
r/w
r/w
BitPhase
Access
Rights
r/w
r/w
r/w
r/w
Description of the bits
Bit
Symbol
7-0
BitPase
Function
Defines the phase relation between transmitter and receiver clock.
Note: The correct value of this register is essential for proper operation.
39
Preliminary
Philips Semiconductors
Product Specification Rev. 2.0 November 2001
I•CODE Reader IC
5.2.4.5
SL RC400
RxThreshold Register
selects thresholds for the bit decoder.
Name: RxThreshold
Address: 0x1C
7
6
5
Reset value: 01101000, 0x68
4
3
2
MinLevel
Access
Rights
r/w
r/w
1
0
r/w
r/w
CollLevel
r/w
r/w
r/w
r/w
Description of the bits
Bit
Symbol
7-4
MinLevel
Function
Defines the minimum signal strength at the decoder input that shall be accepted.
If the signal strength is below this level, it is not evaluated.
3-0
5.2.4.6
CollLevel
Defines the minimum signal strength at the decoder input that has to be reached
by the weaker half-bit of the Manchester-coded signal to generate a bit-collision
relatively to the amplitude of the stronger half-bit.
PreSet1D Register
Name: PreSet1D
Access
Rights
Address: 0x1D
Reset value: 00000000, 0x00
7
6
5
4
3
2
1
0
0
0
0
0
0
0
0
0
r/w
r/w
r/w
r/w
r/w
r/w
r/w
r/w
Note: These values shall not be changed !
40
Preliminary
Philips Semiconductors
Product Specification Rev. 2.0 November 2001
I•CODE Reader IC
5.2.4.7
SL RC400
RxControl2 Register
controls decoder behaviour and defines the input source for the receiver.
Name:RxControl2
Access
Rights
Address: 0x1E
Reset value: 01000001, 0x41
7
6
5
4
3
2
RcvClkSelI
RxAutoPD
0
0
0
0
r/w
r/w
r/w
R/w
r/w
r/w
1
0
DecoderSource
r/w
r/w
Description of the bits
Bit
Symbol
Function
7
RcvClkSelI
If set to 1, the I-clock is used for the receiver clock.
0 indicates, the Q-clock is used. I-clock and Q-clock are 90° phase shifted to each
other
6
RxAutoPD
If set to 1, the receiver circuit is automatically switched on before receiving and
switched off afterwards. This may be used to reduce current consumption.
If set to 0, the receiver is always activated.
5-2
0000
1-0
DecoderSource
These values shall not be changed
Selects the source for the decoder input:
00: Low
01: Internal Demodulator
10: RFU
11: RFU
41
Preliminary
Philips Semiconductors
Product Specification Rev. 2.0 November 2001
I•CODE Reader IC
5.2.4.8
SL RC400
ClockQControl Register
controls clock generation for the 90° phase shifted Q-channel clock.
Name: ClockQControl
Address: 0x1F
7
6
5
ClkQ180Deg
ClkQCalib
0
r
r/w
r/w
Access
Rights
Reset value: 000XXXXX, 0xXX
4
3
2
1
0
dy
dy
ClkQDelay
dy
dy
dy
Description of the bits
Bit
Symbol
7
ClkQ180Deg
6
ClkQCalib
5
0
4-0
ClkQDelay
Function
If the Q-clock is phase shifted more than 180° compared to the I-clock, this bit is
set to 1, otherwise it is 0.
If this bit is 0, the Q-clock is calibrated automatically after the Reset Phase and
after data reception from the label.
If this bit is set to 1, no calibration is performed automatically.
This value shall not be changed
This register shows the number of delay elements actually used to generate a 90°
phase shift of the I-clock to obtain the Q-clock.
It can be written directly by the µ-Processor or by the automatic calibration cycle.
42
Preliminary
Philips Semiconductors
Product Specification Rev. 2.0 November 2001
I•CODE Reader IC
5.2.5
SL RC400
PAGE 4: RF-TIMING AND CHANNEL REDUNDANCY
5.2.5.1
Page Register
Selects the register page. See 5.2.1.1 Page register.
5.2.5.2
RxWait Register
Selects the time interval after transmission, before receiver starts.
Name: RxWait
Address: 0x21
7
6
5
Reset value: 00001000, 0x08
4
3
2
1
0
r/w
r/w
r/w
r/w
RxWait
Access
Rights
r/w
r/w
r/w
r/w
Description of the bits
Bit
Symbol
7-0
RxWait
Function
After data transmission, the activation of the receiver is delayed for RxWait bitclocks (proportional to CoderRate). During this ‘frame guard time’ any signal at
pin Rx is ignored.
43
Preliminary
Philips Semiconductors
Product Specification Rev. 2.0 November 2001
I•CODE Reader IC
5.2.5.3
SL RC400
ChannelRedundancy Register
Selects kind and mode of checking the data integrity on the RF-channel.
Name: ChannelRedundancy
Access
Rights
Address: 0x22
Reset value: 00001100, 0x0C
7
6
5
4
3
2
1
0
0
CRCMSB
First
CRC
3309
CRC8
RxCRCEn
TxCRCEn
0
0
r/w
r/w
r/w
r/w
r/w
r/w
r/w
r/w
Description of the bits
Bit
Symbol
7
0
6
CRCMSBFirst
Function
This value shall not be changed
If set to 1, CRC-calculation shifts the MSBit into the CRC-Coprocessor first.
If set to 0, CRC-calculation starts with the LSBit.
Note: For usage according ISO 15693 and I?CODE1 this bit has to be 0.
5
CRC 3309
If set to 1, CRC-calculation is done according ISO/IEC3309 as it is defined in
ISO 15693.
Note: For usage according to I•CODE1 this bit has to be 0.
4
CRC8
If set to 1, an 8-bit CRC is calculated.
If set to 0, a 16-bit CRC is calculated.
3
RxCRCEn
If set to 1, the last byte(s) of a received frame is/are interpreted as CRC byte/s.
If the CRC itself is correct the CRC byte(s) is/are not passed to the FIFO.
In case of an error, the CRCErr flag is set.
If set to 0, no CRC is expected.
2
TxCRCEn
If set to 1, a CRC is calculated over the transmitted data and the CRC byte(s) are
appended to the data stream.
If set to 0, no CRC is transmitted.
1-0
00
RFU
44
Preliminary
Philips Semiconductors
Product Specification Rev. 2.0 November 2001
I•CODE Reader IC
5.2.5.4
SL RC400
CRCPresetLSB Register
LSB of the preset value for the CRC register.
Name: CRCPresetLSB
7
Address: 0x23
6
5
Reset value: 11111110, 0xFE
4
3
2
1
0
r/w
r/w
r/w
CRCPresetLSB
Access
Rights
r/w
r/w
r/w
r/w
r/w
Description of the bits
Bit
Symbol
Function
7-0
CRCPresetLSB
CRCPresetLSB defines the starting value for CRC-calculation. This value is
loaded into the CRC at the beginning of transmission, reception and the CalcCRC
Command, if the CRC calculation is enabled.
The Preset value is set for I?CODE1
To use the ISO 15693 functionality the CRCPresetLSB Register has to be set to
0xFF.
5.2.5.5
CRCPresetMSB Register
MSB of the preset value for the CRC register.
Name: CRCPresetMSB
7
Address: 0x24
6
5
Reset value: 11111111, 0xFF
4
3
2
1
0
r/w
r/w
r/w
CRCPresetMSB
Access
Rights
r/w
r/w
r/w
r/w
r/w
Description of the bits
Bit
Symbol
Function
7-0
CRCPresetMSB
CRCPresetMSB defines the starting value for CRC-calculation. This value is
loaded into the CRC at the beginning of transmission, reception and the CalcCRC
Command, if the CRC calculation is enabled.
Note: The Preset value of CRCPresetMSB Register is the same for I?CODE1 and
ISO 15693.
Note: This register is not relevant, if CRC8 is 1.
45
Preliminary
Philips Semiconductors
Product Specification Rev. 2.0 November 2001
I•CODE Reader IC
5.2.5.6
SL RC400
TimeSlotPeriod Register
Name: TimeSlotPeriod
7
Address: 0x25
6
5
Reset value: 00000000, 0x00
4
3
2
1
0
r/w
r/w
r/w
TimeSlotPeriod
Access
Rights
r/w
r/w
r/w
r/w
r/w
Description of the bits
Bit
Symbol
Function
7-0
TimeSlotPeriod
TimeSlotPeriod defines the time between automatically mitted Frames. To send a
Quit-Frame according to the I•CODE1 protocol, it is necessary to have a relation
to the beginning of the Command-Frame. The TimeSlotPeriod will start at the End
of the Command transmission. For detailed information see also chapter 9.2.5
46
Preliminary
Philips Semiconductors
Product Specification Rev. 2.0 November 2001
I•CODE Reader IC
5.2.5.7
SL RC400
SIGOUTSelect Register
Selects internal signal applied to pin SIGOUT.
Name: SIGOUTSelect
Access
Rights
Address: 0x26
7
6
5
0
0
0
r/w
r/w
r/w
Reset value:00000000, 0x00
4
TimeSlot
Period
MSB
r/w
3
2
0
r/w
1
0
SIGOUTSelect
r/w
r/w
r/w
Description of the bits
Bit
Symbol
7-5
000
4
TimeSlotPeriod
MSB
3
0
2-0
SIGOUTSelect
Function
These values shall not be changed
MSB of value TimeSlotPeriod see register 0x25
These values shall not be changed
SIGOUTSelect defines which signal is routed to pin SIGOUT.
000
Constant Low
001
Constant High
010
Modulation Signal (envelope) from internal coder, actual used coded
011
Serial data stream
100
Output signal of the carrier frequency demodulator (label modulation
signal)
101
Output signal of the subcarrier demodulator (Manchester coded label
signal)
110
RFU
111
RFU
47
Preliminary
Philips Semiconductors
Product Specification Rev. 2.0 November 2001
I•CODE Reader IC
5.2.5.8
SL RC400
PreSet27 Register
Name: PreSet27
Access
Rights
Address: 0x27
Reset value: 00000000, 0x00
7
6
5
4
3
2
1
0
0
0
0
0
0
0
0
0
r/w
r/w
r/w
r/w
r/w
r/w
r/w
r/w
Note: These values shall not be changed !
5.2.6
PAGE 5: FIFO, TIMER AND IRQ- PIN CONFIGURATION
5.2.6.1
Page Register
Selects the register page. See 5.2.1.1 Page register.
5.2.6.2
FIFOLevel Register
Defines the level for FIFO under- and overflow warning.
Name: FIFOLevel
Access
Rights
Address: 0x29
7
6
0
0
r/w
r/w
5
Reset value:00111110, 0x3E
4
3
2
1
0
r/w
r/w
r/w
WaterLevel
r/w
r/w
r/w
Description of the bits
Bit
Symbol
7-6
00
5-0
WaterLevel
Function
These values shall not be changed
This register defines, the warning level of the SL RC400 for the µ-Processor for a
FIFO-buffer over- or underflow:
HiAlert is set to 1, if the remaining FIFO-buffer space is equal or less than
WaterLevel bytes in the FIFO-buffer.
LoAlert is set to 1, if equal or less than WaterLevel bytes are in the FIFO-buffer,.
48
Preliminary
Philips Semiconductors
Product Specification Rev. 2.0 November 2001
I•CODE Reader IC
5.2.6.3
SL RC400
TimerClock Register
Selects the devider for the timer clock.
Name: TimerClock
Access
Rights
Address: 0x2A
7
6
5
0
0
TAutoRestart
r/w
r/w
r/w
Reset value: 00001011, 0x0B
4
3
2
1
0
r/w
r/w
TPreScaler
r/w
r/w
r/w
Description of the bits
Bit
Symbol
7-6
00
5
TAutoRestart
4-0
TPreScaler
Function
These values shall not be changed
If set to 1, the timer automatically restart its count-down from TReloadValue,
instead of counting down to zero.
If set to 0 the timer decrements to zero and the bit TimerIRq is set to 1.
Defines the timer clock fTimer. TPreScaler can be adjusted from 0x00 up to 0x15.
The following formula is used to calculate fTimer :
TPreScaler
fTimer = 13.56 MHz / 2
.
49
Preliminary
Philips Semiconductors
Product Specification Rev. 2.0 November 2001
I•CODE Reader IC
5.2.6.4
SL RC400
TimerControl Register
Selects start and stop conditions for the timer.
Name: TimerControl
Access
Rights
Address: 0x2B
Reset value: 00000010, 0x02
7
6
5
4
3
2
1
0
0
0
0
0
TStopRxEnd
TStopRxBegin
TStartTxEnd
TStartTxBegin
r/w
r/w
r/w
r/w
r/w
r/w
r/w
r/w
Description of the bits
Bit
Symbol
Function
7-4
0000
3
TStopRxEnd
2
TStopRxBegin
If set to 1, the timer is stopped automatically, when the first valid bit is received.
0 indicates, that the timer is not influenced by this condition.
1
TStartTxEnd
If set to 1, the timer is started automatically when data transmission ends. If the
timer is already running, it is restarted by loading TReloadValue into the timer.
0 indicates, that the timer is not influenced by this condition.
0
TStartTxBegin
These values shall not be changed
If set to 1, the timer is stopped automatically when data reception ends.
0 indicates, that the timer is not influenced by this condition.
If set to 1, the timer is started automatically when the first bit is transmitted. If the
timer is already running, it is restarted by loading TReloadValue into the timer.
0 indicates, that the timer is not influenced by this condition.
50
Preliminary
Philips Semiconductors
Product Specification Rev. 2.0 November 2001
I•CODE Reader IC
5.2.6.5
SL RC400
TimerReload Register
Defines the preset value for the timer.
Name: TimerReload
7
Address: 0x2C
6
5
Reset value: 00000000, 0x00
4
3
2
1
0
r/w
r/w
r/w
TReloadValue
Access
Rights
r/w
r/w
r/w
r/w
r/w
Description of the bits
Bit
Symbol
7-0
TReloadValue
Function
With a start event the timer loads with the TreloadValue. Changing this register
affects the timer only with the next start event.
If TReloadValue is set to 0, the timer cannot start.
51
Preliminary
Philips Semiconductors
Product Specification Rev. 2.0 November 2001
I•CODE Reader IC
5.2.6.6
SL RC400
IRQPinConfig Register
Configures the output stage for pin IRQ.
Name: IRQPinConfig
Access
Rights
Address: 0x2D
Reset value: 00000010, 0x02
7
6
5
4
3
2
1
0
0
0
0
0
0
0
IRQInv
IRQPushPull
r/w
r/w
r/w
r/w
r/w
r/w
r/w
r/w
Description of the bits
Bit
Symbol
7-2
000000
These values shall not be changed
1
IRQInv
If set to 1, the signal on pin IRQ is inverted with respect to bit IRq.
0 indicates, that the signal on pin IRQ is equal to bit IRQ.
0
IRQPushPull
5.2.6.7
Function
If set to 1, pin IRQ works as standard CMOS output pad.
0 indicates, that pin IRQ works as open drain output pad.
PreSet2E
Name: PreSet2E
Access
Rights
Address: 0x2E
Reset value: 00000000, 0x00
7
6
5
4
3
2
1
0
0
0
0
0
0
0
0
0
r/w
r/w
r/w
r/w
r/w
r/w
r/w
r/w
Note: These values shall not be changed !
5.2.6.8
Preset2F
Name: Preset2F
Access
Rights
Address: 0x2F
Reset value: 00000000, 0x00
7
6
5
4
3
2
1
0
0
0
0
0
0
0
0
0
r/w
r/w
r/w
r/w
r/w
r/w
r/w
r/w
Note: These values shall not be changed !
52
Preliminary
Philips Semiconductors
Product Specification Rev. 2.0 November 2001
I•CODE Reader IC
SL RC400
Page 6: RFU
5.2.6.9
Page Register
Selects the register page. See 5.2.1.1 Page register.
5.2.6.10 RFU Registers
Name: RFU
Access
Rights
Address: 0x31, 0x32, 0x33, 0x34,
0x35, 0x36, 037
Reset value:00000000, 0x00
7
6
5
4
3
2
1
0
0
0
0
0
0
0
0
0
r/w
r/w
r/w
r/w
r/w
r/w
r/w
r/w
Note: These registers are reserved for future use.
53
Preliminary
Philips Semiconductors
Product Specification Rev. 2.0 November 2001
I•CODE Reader IC
5.2.7
5.2.7.1
SL RC400
PAGE 7: TEST CONTROL
Page Register
Selects the register page. See 5.2.1.1 Page register.
5.2.7.2
RFU Register
Name: RFU
Address: 0x39
Reset value: 00000000, 0x00
7
6
5
4
3
2
1
0
0
0
0
0
0
0
0
0
w
w
w
w
w
Access
w
w
w
Rights
Note: These registers are reserved for future use.
54
Preliminary
Philips Semiconductors
Product Specification Rev. 2.0 November 2001
I•CODE Reader IC
5.2.7.3
SL RC400
TestAnaSelect Register
Selects analog test signals.
Name: TestAnaSelect
Access
Rights
Address: 0x3A
Reset value: 00000000, 0x00
7
6
5
4
0
0
0
0
w
w
w
w
3
2
1
0
TestAnaOutSelect
w
w
w
w
Description of the bits
Bit
Symbol
7-4
0000
3-0
TestAnaOutSel
Function
These values shall not be changed
This register selects the internal analog signal that is routed to pin AUX.
For detailed information see 18.3
Value
Signal Name
0
Vmid
1
Vbandgap
2
VRxFollI
3
VRxFollQ
4
VRxAmpI
5
VRxAmpQ
6
VCorrNI
7
VCorrNQ
8
VCorrDI
9
VCorrDQ
A
VEvalL
B
VEvalR
C
VTemp
D
RFU
E
RFU
F
RFU
55
Preliminary
Philips Semiconductors
Product Specification Rev. 2.0 November 2001
I•CODE Reader IC
5.2.7.4
SL RC400
PreSet3B
Name: PreSet3B
Access
Rights
Address: 0x3B
Reset value: 00000000, 0x00
7
6
5
4
3
2
1
0
0
0
0
0
0
0
0
0
w
w
w
w
w
w
w
w
Note: These values shall not be changed !
5.2.7.5
PreSet3C
Name: PreSet3C
Access
Rights
Address: 0x3C
Reset value: 00000000, 0x00
7
6
5
4
3
2
1
0
0
0
0
0
0
0
0
0
w
w
w
w
w
w
w
w
Note: These values shall not be changed !
56
Preliminary
Philips Semiconductors
Product Specification Rev. 2.0 November 2001
I•CODE Reader IC
5.2.7.6
SL RC400
TestDigiSelect Register
Selects digital test mode.
Name: TestDigiSelect
7
Address:0x3D
6
5
Reset value: 00000000, 0x00
4
SignalTo
SIGOUT
Access
Rights
w
3
2
1
0
w
w
w
TestDigiSignalSel
w
w
w
w
Description of the bits
Bit
Symbol
Function
7
SignalToSIGOUT
Set to 1, overrules the setting in SIGOUTSelect and the digital test signal
defined in TestDigiSignalSel is routed to pin SIGOUT instead.
Set to 0, SIGOUTSelect defines the signal delivered at pin SIGOUT.
6-0
TestDigiSignalSel
Selects the digital test signal to be routed to pin SIGOUT.
For detailed information refer to chapter 18.4
5.2.7.7
TestDigiSelect
Signal Name
74hex
s_data
64hex
s_valid
54hex
s_coll
44hex
s_clock
35hex
rd_sync
25hex
wr_sync
16hex
int_clock
RFU Registers
Name: RFU
Address: 0x3E, 0x3F
Reset value: 00000000, 0x00
7
6
5
4
3
2
1
0
0
0
0
0
0
0
0
0
r/w
r/w
r/w
r/w
r/w
Access
r/w
r/w
r/w
Rights
Note: These registers are reserved for future use.
57
Preliminary
Philips Semiconductors
Product Specification Rev. 2.0 November 2001
I•CODE Reader IC
5.3
SL RC400
SL RC400 Register Flags Overview
Flag(s)
Register
Address
Register, Bit Position
AccessErr
ErrorFlag
0x0A, bit 5
BitPhase
BitPhase
0x1B, bits 7:0
ClkQ180Deg
ClockQControl
0x1F, bit 7
ClkQCalib
ClockQControl
0x1F, bit 6
ClkQDelay
ClockQControl
0x1F, bits 4:0
CollErr
ErrorFlag
0x0A, bit 0
CollLevel
RxThreshold
0x1C, bits 3:0
CollPos
CollPos
0x0B, bits 7:0
Command
Command
0x01, bits 5:0
CRC3309
ChannelRedundancy
0x22, bit 5
CRC8
ChannelRedundancy
0x22, bit 4
CRCErr
ErrorFlag
0x0A, bit 3
CRCMSBFirst
ChannelRedundancy
0x22, bit 6
CRCPresetLSB
CRCPresetLSB
0x23, bits 7:0
CRCPresetMSB
CRCPresetMSB
0x24, bits 7:0
CRCReady
SecondaryStatus
0x05 , bit 5
CRCResultMSB
CRCResultMSB
0x0E, bits 7:0
CRCResultLSB
CRCResultLSB
0x0D, , bits 7:0
DecoderSource
RxControl2
0x1E, bits 1:0
E2Ready
SecondaryStatus
0x05, bit 6
Err
PrimaryStatus
0x03, bit 2
FIFOData
FIFOData
0x02, bits 7:0
FIFOLength
FIFOLength
0x04, bits 7:0
FIFOOvfl
ErrorFlag
0x0A, bit 4
FlushFIFO
Control
0x09, bit 0
FramingErr
ErrorFlag
0x0A, bit 2
Gain
RxControl1
0x19, bits 1:0
GsCfgCW
CWConductance
0x12, bits 5:0
GsCfgMod
ModConductance
0x13, bits 5:0
HiAlert
PrimaryStatus
0x03, bit 1
HiAlertIEn
InterruptEn
0x06, bit 1
HiAlertIRq
InterruptRq
0x07, bit 1
58
Preliminary
Philips Semiconductors
Product Specification Rev. 2.0 November 2001
I•CODE Reader IC
Flag(s)
SL RC400
Register
Address
Register, Bit Position
IdleIEn
InterruptEn
0x06, bit 2
IdleIRq
InterruptRq
0x07, bit 2
IFDetectBusy
Command
0x01, bit 7
IRq
PrimaryStatus
0x03, bit 3
IRQInv
IRQPinConfig
0x2D, bit 1
IRQPushPull
IRQPinConfig
0x2D, bit 0
LoAlert
PrimaryStatus
0x03, bit 0
LoAlertIEn
InterruptEn
0x06, bit 0
LoAlertIRq
InterruptRq
0x07, bit 0
SIGOUTSelect
SIGOUTSelect
0x26, bits 2:0
MinLevel
RxThreshold
0x1C, bits 7:4
ModemState
PrimaryStatus
0x03 , bit 6:4
ModulatorSource
TxControl
0x11, bits 6:5
ModWidth
ModWidth
0x15, bits /:0
Page
0x00, 0x08, 0x10, 0x18, 0x20,
0x28, 0x30, 0x38, bits 2:0
PowerDown
Control
0x09, bit4
RcvClkSelI
RxControl2
0x1E, bit 7
RxAutoPD
RxControl2
0x1E, bit 6
RxCRCEn
ChannelRedundancy
0x22, bit 3
RxIEn
InterruptEn
0x06, bit 3
RxIRq
InterruptRq
0x07, bit 3
RxLastBits
SecondaryStatus
0x05, bits 2:0
RxWait
RxWait
0x21, bits 7:0
SetIEn
InterruptEn
0x06, bit 67
SetIRq
InterruptRq
0x07, bit 7
SignalToSIGOUT
TestDigiSelect
0x3D, bit 7
StandBy
Control
0x09, bit 5
TAutoRestart
TimerClock
0x2A, bit 5
TestAnaOutSel
TestAnaSelect
0x3A, bits 6:4
TestDigiSignalSel
TestDigiSelect
0x3D, bit 6:0
TimerIEn
InterruptEn
0x06, bit 5
TimerIRq
InterruptRq
0x07, bit 5
TimerValue
TimerValue
0x0C, bits 7:0
PageSelect
59
Preliminary
Philips Semiconductors
Product Specification Rev. 2.0 November 2001
I•CODE Reader IC
Flag(s)
SL RC400
Register
Address
Register, Bit Position
TPreScaler
TimerClock
0x2A, bits 4:0
TReloadValue
TimerReload
0x2C, bits 7:0
TRunning
SecondaryStatus
0x05, bit 7
TStartTxBegin
TimerControl
0x2B, bit 0
TStartTxEnd
TimerControl
0x2B, bit 1
TStartNow
Control
0x09, bit 1
TStopRxBegin
TimerControl
0x2B, bit 2
TStopRxEnd
TimerControl
0x2B, bit 3
TStopNow
Control
0x09, bit 2
TX1RFEn
TxControl
0x11, bit 0
TX2Cw
TxControl
0x11, bit 3
TX2Inv
TxControl
0x11, bit 3
TX2RFEn
TxControl
0x11, bit 1
TxCRCEn
ChannelRedundancy
0x22, bit 2
TxIEn
InterruptEn
0x06, bit 4
TxIRq
InterruptRq
0x07, bit 4
TxLastBits
BitFraming
0x0F, bits 2:0
Page
0x00, 0x08, 0x10, 0x18, 0x20,
0x28, 0x30, 0x38, bit 7
WaterLevel
FIFOLevel
0x29, bits 5:0
ZeroAfterColl
DecoderControl
0x1A, bit 5
UsePageSelect
60
Preliminary
Philips Semiconductors
Product Specification Rev. 2.0 November 2001
I•CODE Reader IC
5.4
SL RC400
Modes of Register Addressing
There are three mechanisms to operate the SL RC400:
•
Initiating functions and controlling data manipulation by executing commands
•
Configuring electrical and functional behaviour via a set of configuration bits
•
Monitoring the state of the SL RC400 by reading status flags
The commands, configurations bits and flags are accessed via the µ-Processor interface.
The SL RC400 can internally address 64 registers. This basically requires six address lines.
5.4.1
PAGING MECHANISM
The SL RC400 register set is segmented into 8 pages with 8 register each. The Page-Register can always
be addressed, no matter which page is currently selected.
5.4.2
DEDICATED ADDRESS BUS
Using the SL RC400 with dedicated address bus, the µ-Processor defines three address lines via the
address pins A0, A1, and A2. This allows addressing within a page. To switch between registers in different
pages the paging mechanism needs then to be used.
The following table shows how the register address is assembled:
Register Bit:
UsePageSelect
1
Register-Address
PageSelect2
PageSelect1
PageSelect0
A2
A1
A0
Table 5-3: Dedicated Address Bus: Assembling the Register Address
5.4.3
MULTIPLEXED ADDRESS BUS
Using the SL RC400 with multiplexed address bus, the µ-Processor may define all six address lines at once.
In this case either the paging mechanism or linear addressing may be used.
The following table shows how the register address is assembled:
Interface Bus Type
Register Bit:
UsePageSelect
Multiplexed Address Bus
(paging mode)
1
PageSelect2
PageSelect1
PageSelect0
AD2
AD1
AD0
Multiplexed Address Bus
(linear addressing)
0
AD5
AD4
AD3
AD2
AD1
AD0
Register-Address
Table 5-4: Multiplexed Address Bus: Assembling the Register Address
61
Preliminary
Philips Semiconductors
Product Specification Rev. 2.0 November 2001
I•CODE Reader IC
6
SL RC400
MEMORY ORGANISATION OF THE E²PROM
6.1
Diagram of the E²PROM Memory Organisation
Block
Number
Block Address
Byte
Addresses
Access Rights
Memory Content
See
Also
0
0
00 … 0F
r
Product Information Field
6.2
1
1
10 … 1F
r/w
Start Up Register Initialisation File
6.3.1
2
2
20 … 2F
r/w
3
3
30 … 3F
r/w
4
4
40 … 4F
r/w
5
5
50 … 5F
r/w
6
6
60 … 6F
r/w
7
7
70 … 7F
r/w
Register Initialisation File
6.3.3
For User data or second Initialisation
Table 6-1:Diagram of E²PROM Memory Organisation
Note: It is strictly recommended to use only the described E²PROM address area.
6.2
Product Information Field (Read Only)
Byte
Meaning
0
1
2
3
4
5
Product Type Identification
6
RFU
7
8
9
10
11
12
Product Serial Number
13
Internal
14
15
RsMaxP
CRC
Table 6-2: Product Information Field
PRODUCT TYPE IDENTIFICATION
The SL RC400 is a member of a new family for highly integrated reader IC’s. Each member of the product
family has its unique Product Type Identification. The value of the Product Type Identification is shown in the
table below:
Product Type Identification
Byte
0
1
2
3
4
Value
30hex
33hex
F1 hex
00hex
XXhex
Table 6-3: Product Type Identification Definition
62
Preliminary
Philips Semiconductors
Product Specification Rev. 2.0 November 2001
I•CODE Reader IC
SL RC400
PRODUCT SERIAL NUMBER
The SL RC400 holds a four byte serial number that is unique for each device.
INTERNAL:
These 2 bytes hold internal trimming parameters.
MAXIMUM SOURCE RESISTANCE FOR THE P-CHANNEL DRIVER TRANSISTOR OF PIN TX1 AND TX2
The source resistance of the p-channel driver transistors of pin TX1 and TX2 may be adjusted via the
GsConfCW Register (see chapter 13.2.1). The mean value of the maximum adjustable source resistance of
the pins TX1 and TX2 is stored as an integer value in Ohms in byte RsMaxP.
This value is denoted as maximum adjustable source resistance Rs ref,max,n and is measured with GsConfCW
Register set to 01hex . It is in the range between about 80 to 120 O.
CRC
The content of the product information field is secured via a CRC-byte, which is checked during start up.
6.3
Register Initialisation Files (Read/Write)
Register initialisation in the register address range from 10hex to 2Fhex is done automatically during the
Initialising Phase (see 11.3), using the Start Up Register Initialisation File.
Furthermore, the user may initialise the SL RC400 registers with values from the Register Initialisation File
executing the LoadConfig-Command (see 16.6.1).
Notes:
•
The Page-Register (addressed with 10hex , 18hex , 20hex , 28hex ) is skipped and not initialised.
•
Make sure that all PreSet registers are not changed.
•
Make sure, that all register bits that are reserved for future use (RFU) are set to 0.
6.3.1
START UP REGISTER INITIALISATION FILE (READ/WRITE)
The content of the E²PROM memory block address 1 and 2 are used to initialise the SL RC400 registers
10hex to 2Fhex during the Initialising Phase automatically. The default values written into the E²PROM during
production are shown in chapter 6.3.2.
The assignment is the following:
E²PROM Byte Address
Register Address
Remark
10hex (Block 1, Byte 0)
10hex
Skipped
11hex
11hex
Copied
…
…
2Fhex
Copied
…
2Fhex (Block 2, Byte 15)
Table 6-4: Byte Assignment for Register Initialisation at Start Up
63
Preliminary
Philips Semiconductors
Product Specification Rev. 2.0 November 2001
I•CODE Reader IC
6.3.2
SL RC400
SHIPMENT CONTENT OF START UP REGISTER INITIALISATION FILE
During production test, the Start Up Register Initialisation File is initialised with the values shown in the table
below. With each power up these values are written into the SL RC400 register during the Initialising Phase.
E²PROM Byte
Address
Reg.
Address
Value
10
10
00
Page: free for user
11
11
58
TxControl: Transmitter pins TX1 and TX2 switched off, bridge driver configuration,
modulator driven from internal digital circuitry
12
12
3F
CwConductance: Source resistance of TX1 and TX2 to minimum.
13
13
05
ModGsCfg: Source resistance of TX1 and TX2 at the time of Modulation, to determine
the modulation index
14
14
2C
CoderControl: Selects the bit coding mode and the framing during transmission
15
15
3F
ModWidth: Pulse width for “used code (1 out of 256, RZ or 1 out of 4)” pulse coding is
set to standard configuration.
16
16
3F
ModWidthSOF Pulse width of SOF
17
17
00
PreSet17
18
18
00
Page: free for user
19
19
8B
RxControl1: Amplifier gain is maximum.
1A
1A
00
DecoderControl: A bit-collision always evaluates to HIGH in the data bit stream.
1B
1B
54
BitPhase: BitPhase is set to standard configuration.
1C
1C
68
RxThreshold: MinLevel and CollLevel are set to maximum.
1D
1D
00
PreSet1D
1E
1E
41
RxControl2: Use Q-clock for the receiver, ‘Automatic Receiver Off’ is switched on,
decoder is driven from internal analog circuitry.
1F
1F
00
ClockQControl: Automatic Q-clock Calibration’ is switched on.
20
20
00
Page: free for user
21
21
08
RxWait: Frame Guard Time is set to six bit clocks.
22
22
0C
ChannelRedundancy: Channel Redundancy is set according to I?CODE1.
23
23
FE
CRCPresetLSB: CRC-Preset value is set according to I?CODE1.
24
24
FF
CRCPresetMSB: CRC-Preset value is set according to I?CODE1.
25
25
00
PreSet25
26
26
00
SIGOUTSelect: Pin SIGOUT is set to LOW.
27
27
00
PreSet27
28
28
00
Page: free for user
29
29
3E
FIFOLevel: WaterLevel: FIFO buffer warning level is set to standard configuration.
2A
2A
0B
TimerClock: TPreScaler is set to standard configuration, timer unit restart function is
switched off.
2B
2B
02
TimerControl: Timer is started at the end of transmission, stopped at the beginning of
reception.
2C
2C
00
TimerReload: TReloadValue: the timer unit preset value is set to standard configuration
2D
2D
02
IRQPinConfig: Pin IRQ is set to high impedance.
2E
2E
00
PreSet2E
2F
2F
00
PreSet2F
Description
Table 6-5: Shipment Content of Start Up Configuration File
64
Preliminary
Philips Semiconductors
Product Specification Rev. 2.0 November 2001
I•CODE Reader IC
6.3.3
SL RC400
REGISTER INITIALISATION FILE (READ/WRITE)
The content of the E²PROM memory from block address 3 to 7 may be used to initialise the SL RC400
registers 10hex to 2Fhex by execution of the LoadConfig-Command (see 16.6.1). It requires a two byte
argument, that is used as the two byte long E²PROM starting byte address for the initialisation procedure.
The assignment is the following:
E²PROM Byte Address
Register Address
Remark
Starting Byte address for the E²PROM
10hex
Skipped
Starting Byte address for the E²PROM +1
11hex
Copied
…
…
…
Starting Byte address for the E²PROM + 31
2Fhex
Copied
Table 6-6: Byte Assignment for Register Initialisation at Start Up
The Register Initialisation File is big enough to hold the values for two initialisation sets and leaves one more
block (16 bytes) for the user.
Note: The Register Initialisation File is read- and write-able for the user. Therefore, these bytes may also be
used to store user specific data for other purposes.
65
Preliminary
Philips Semiconductors
Product Specification Rev. 2.0 November 2001
I•CODE Reader IC
7
SL RC400
FIFO BUFFER
7.1
Overview
An 8x64 bit FIFO buffer is implemented in the SL RC400 acting as a parallel-to-parallel converter. It buffers
the input and output data stream between the µ-Processor and the internals of the SL RC400. Thus, it is
possible to handle data streams with lengths of up to 64 bytes without taking timing constraints into account.
7.2
Accessing the FIFO Buffer
7.2.1
ACCESS RULES
The FIFO-buffer input and output data bus is connected to the FIFOData Register. Writing to this register
stores one byte in the FIFO-buffer and increments the internal FIFO-buffer write-pointer. Reading from this
register shows the FIFO-buffer content stored at the FIFO-buffer read-pointer and increments the FIFObuffer read-pointer. The distance between the write- and read-pointer can be obtained by reading the
FIFOLength Register.
When the µ-Processor starts a command, the SL RC400 may, while the command is in progress, access the
FIFO-buffer according to that command. Physically only one FIFO-buffer is implemented, which can be used
in input- and output direction. Therefore the µ-Processor has to take care, not to access the FIFO-buffer in
an unintended way.
The following table gives an overview on FIFO access during command processing:
Active Command
µ-Processor is allowed to
Write to FIFO
Read from FIFO
StartUp
-
-
Idle
-
-
Transmit
ü
-
Receive
-
ü
Transceive
ü
ü
WriteE2
ü
-
ReadE2
ü
ü
LoadConfig
ü
-
CalcCRC
ü
-
Remark
µ-Processor has to know the actual state of the command
(transmitting or receiving)
The µ-Processor has to prepare the arguments,
then only reading is allowed
Table 7-1: Allowed Access to the FIFO-Buffer
7.3
Controlling the FIFO-Buffer
Besides writing and reading the FIFO-buffer, the FIFO-buffer pointers may be reset by setting the bit
FlushFIFO. The consequence is, that FIFOLength becomes zero, FIFOOvfl is cleared, the actually stored
bytes are not accessible anymore and the FIFO-buffer can be filled with another 64 bytes again.
66
Preliminary
Philips Semiconductors
Product Specification Rev. 2.0 November 2001
I•CODE Reader IC
7.4
SL RC400
Status Information about the FIFO-Buffer
The µ-Processor may obtain the following data about the FIFO-buffers status:
•
•
•
Number of bytes already stored in the FIFO-buffer: FIFOLength
Warning, that the FIFO-buffer is quite full: HiAlert
Warning, that the FIFO-buffer is quite empty: LoAlert
•
Indication, that bytes were written to the FIFO-buffer although it was already full: FIFOOvfl
FIFOOvfl can be cleared only by setting bit FlushFIFO.
The SL RC400 can generate an interrupt signal
• If LoAlertIRq is set to 1 it will activate Pin IRQ when LoAlert changes to 1.
• If HiAlertIRq is set to 1 it will activate Pin IRQ when HiAlert changes to 1.
The flag HiAlert is set to 1 if only WaterLevel bytes or less can be stored in the FIFO-buffer. It is generated
by the following equation:
HiAlert = (64 − FIFOLength) ≤ WaterLevel
The flag LoAlert is set to 1 if WaterLevel bytes or less are actually stored in the FIFO-buffer. It is generated
by the following equation:
LoAlert = FIFOLength ≤ WaterLevel
67
Preliminary
Philips Semiconductors
Product Specification Rev. 2.0 November 2001
I•CODE Reader IC
7.5
SL RC400
Register overview FIFO Buffer
The following table shows the related flags of the FIFO buffer in alphabetic order.
Flags
Register
Address
Register, bit position
FIFOLength
FIFOLength
0x04, bits 6-0
FIFOOvfl
ErrorFlag
0x0A, bit 4
FlushFIFO
Control
0x09, bit 0
HiAlert
PrimaryStatus
0x03, bit 1
HiAlertIEn
InterruptIEn
0x06, bit 1
HiAlertIRq
InterruptIRq
0x07, bit 1
LoAlert
PrimaryStatus
0x03, bit 0
LoAlertIEn
InterruptIEn
0x06, bit 0
LoAlertIRq
InterruptIRq
0x07, bit 0
WaterLevel
FIFOLevel
0x29, bits 5-0
Table 7-2. Registers associated with the FIFO Buffer
68
Preliminary
Philips Semiconductors
Product Specification Rev. 2.0 November 2001
I•CODE Reader IC
8
SL RC400
INTERRUPT REQUEST SYSTEM
8.1
Overview
The SL RC400 indicates certain events by setting bit IRq in the PrimaryStatus-Register and, in addition, by
activating pin IRQ. The signal on pin IRQ may be used to interrupt the µ-Processor using its interrupt
handling capabilities. This allows the implementation of efficient µ-Processor software.
8.1.1
INTERRUPT SOURCES OVERVIEW
The following table shows the integrated interrupt flags, the related source and the condition for its setting.
The interrupt flag TimerIRq indicates an interrupt set by the timer unit. The setting is done when the timer
decrements from 1 either down to zero (TAutoRestart flag disabled) or to the TPreLoad value if TAutoRestart
is enabled.
The TxIRq bit indicates interrupts from different sources. If the transmitter is active and the state changes
from sending data to transmitting the end of frame pattern, the transmitter unit sets automatically the interrupt
bit. The CRC coprocessor sets TxIRq after having processed all data from the FIFO buffer. This is indicated
2
by the flag CRCReady = 1. If the E Prom programming has finished the TxIRq bit is set, indicated by the bit
E2Ready = 1.
The RxIRq flag indicates an interrupt when the end of the received data is detected.
The flag IdleIRq is set if a command finishes and the content of the command register changes to idle.
The flag HiAlertIRq is set to 1 if the HiAlert bit is set to one, that means the FIFO buffer has reached the level
indicated by the bit WaterLevel, see chapter 7.4.
The flag LoAlertIRq is set to 1 if the LoAlert bit is set to one, that means the FIFO buffer has reached the
level indicated by the bit WaterLevel, see chapter 7.4.
Interrupt Flag
Interrupt Source
TimerIRq
Timer Unit
the timer counts from 1 to 0
Transmitter
a data stream, transmitted to the label, ends
TxIRq
CRC-Coprocessor
Is set automatically, when
all data from the FIFO buffer has been processed
RxIRq
Receiver
a data stream, received from the label, ends
IdleIRq
Command Register
a command execution finishes
HiAlertIRq
FIFO-buffer
the FIFO-buffer is getting full
LoAlertIRq
FIFO-buffer
the FIFO-buffer is getting empty
Table 8-1: Interrupt Sources
69
Preliminary
Philips Semiconductors
Product Specification Rev. 2.0 November 2001
I•CODE Reader IC
8.2
SL RC400
Implementation of Interrupt Request Handling
8.2.1
CONTROLLING INTERRUPTS AND THEIR STATUS
The SL RC400 informs the µ-Processor about the interrupt request source by setting the according bit in the
InterruptRq Register. The relevance of each interrupt request bit as source for an interrupt may be masked
with the interrupt enable bits of the InterruptEn Register.
Register
Bit 7
Bit 6
Bit 5
Bit 4
Bit 3
Bit 2
Bit 1
Bit 0
InterruptEn
SetIEn
RFU
TimerIEn
TxIEn
RxIEn
IdleIEn
HiAlertIEn
LoAlertIEn
InterruptRq
SetIRq
RFU
TimerIRq
TxIRq
RxIRq
IdleIRq
HiAlertIRq
LoAlertIRq
Table 8-2: Interrupt Control Registers
If any interrupt request flag is set to 1 (showing that an interrupt request is pending) and the corresponding
interrupt enable flag is set the status flag IRq in the PrimaryStatus Register is set to 1. Furthermore, different
interrupt sources can be set active simultaneously. Therefore, all interrupt request bits are ‘OR’ed and
connected to the flag IRq and forwarded to pin IRQ.
8.2.2
ACCESSING THE INTERRUPT REGISTERS
The interrupt request bits are set automatically by the internal state machines of the SL RC400. Additionally
the µ-Processor has access in order to set or to clear them.
A special implementation of the InterruptRq and the InterruptEn Register allows to change the status of a
single bit without influencing the other ones. If a specific interrupt register shall be set to one, the bit SetIxx
has to be set to 1 and simultaneously the specific bit has to be set to 1 too. Vice versa, if a specific interrupt
flag shall be cleared, a zero has to be written to the SetIxx and simultaneously the specific address of the
interrupt register has to be set to 1. If a bit content shall not be changed during the setting or clearing phase
a zero has to be written to the specific bit location.
Example: writing 3Fhex to the InterruptRq Register clears all bits as SetIRq in this case is set to 0 and all
other bits are set to 1. Writing 81hex sets bit LoAlertIRq to 1 and leaves all other bits untouched.
8.3
Configuration of Pin IRQ
The logic level of the status flag IRq is visible at pin IRQ. In addition, the signal on pin IRQ may be controlled
by the following bits of the IRQPinConfig Register:
•
IRQInv: if set to 0, the signal on pin IRQ is equal to the logic level of bit IRq.
If set to 1, the signal on pin IRQ is inverted with respect to bit IRq.
•
IRQPushPull: if set to 1, pin IRQ has standard CMOS output characteristics
otherwise it is an open drain output and an external resistor is necessary to achieve a HIGH level at this
pin.
Note: During the Reset Phase (see 11.2) IRQInv is set 1 and IRQPushPull to 0. This results in a high
impedance at pin IRQ.
70
Preliminary
Philips Semiconductors
Product Specification Rev. 2.0 November 2001
I•CODE Reader IC
8.4
SL RC400
Register Overview Interrupt Request System
The following table shows the related flags of the Interrupt Request System in alphabetic order.
Flags
Register
Address
Register, bit position
HiAlertIEn
InterruptEn
0x06, bit 1
HiAlertIRq
InterruptRq
0x07, bit 1
IdleIEn
InterruptEn
0x06, bit 2
IdleIRq
InterruptRq
0x07, bit 2
IRq
PrimaryStatus
0x03, bit 3
IRQInv
IRQPinConfig
0x07, bit 1
IRQPushPull
IRQPinConfig
0x07, bit 0
LoAlertIEn
InterruptEn
0x06, bit 0
LoAlertIRq
InterruptRq
0x07, bit 0
RxIEn
InterruptEn
0x06, bit 3
RxIRq
InterruptRq
0x07, bit 3
SetIEn
InterruptEn
0x06, bit 7
SetIRq
InterruptRq
0x07, bit 7
TimerIEn
InterruptEn
0x06, bit 5
TimerIRq
InterruptRq
0x07, bit 5
TxIEn
InterruptEn
0x06, bit 4
TxIRq
InterruptRq
0x07, bit 4
Table 8-3 Registers associated with the Interrupt Request System
71
Preliminary
Philips Semiconductors
Product Specification Rev. 2.0 November 2001
I•CODE Reader IC
9
9.1
SL RC400
TIMER UNIT
Overview
A timer is implemented in the SL RC400. It derives its clock from the 13.56 MHz chip-clock. The µ-Processor
may use this timer to manage timing relevant tasks.
The timer unit may be used in one of the following configurations:
•
•
•
•
•
Timeout-Counter
Watch-Dog Counter
Stop Watch
Programmable One-Shot
Periodical Trigger
The timer unit can be used to measure the time interval between two events or to indicate that a specific
event occurred after a specific time. The timer can be triggered by events which will be explained in the
following, but the timer itself does not influence any internal event. A timeout during data receiving does not
influence the receiving process automatically. Furthermore, several timer related flags are set and these
flags can be used to generate an interrupt.
72
Preliminary
Philips Semiconductors
Product Specification Rev. 2.0 November 2001
I•CODE Reader IC
9.2
9.2.1
SL RC400
Implementation of the Timer Unit
BLOCK DIAGRAM
The following block diagram shows the timer module.
TReloadValue [7:0]
TStartTxBegin
TxBegin Event
TStartTxEnd
parallel in
TxEnd Event
start counter /
parallel load
TAutoRestart
TStartNow
Q S
TRunning
Q
R
TStopNow
stop counter
Counter Module
(x <= x-1)
RxEnd Event
TStopRxEnd
RxBegin Event
TStopRxBegin
TPreScaler [4:0]
Clock
Divider
13.56 MHz
>clock
parallel out
to Parallel Interface
TimerValue [7:0]
Counter = 0 ?
to Interrupt Logic: TimerIRq
Figure 9-1: Timer Module Block Diagram
The timer unit is designed in a way, that several events in combination with enabling flags start or stop the
counter. For example, setting the bit TstartTxEnd to 1 enables to control the receiving of data using the timer
unit. In addition the first received bit is indicated by TxEndEvent. This combination starts the counter at the
defined TReloadValue.
The timer stops either automatically if the counter value is equal to zero, or if a defined stop event happens
(TautoRestart not enabled).
73
Preliminary
Philips Semiconductors
Product Specification Rev. 2.0 November 2001
I•CODE Reader IC
9.2.2
SL RC400
CONTROLLING THE TIMER UNIT
The main part of the timer unit is a down-counter. As long as the down-counter value is unequal zero, it
decrements its value with each timer clock.
If TAutoRestart is enabled the timer does not decrement down to zero. Having reached the value 1 the timer
reloads with the next clock with the TimerReload value.
The timer is started by loading a value from the TimerReload Register into the counter module. This may be
triggered by one of the following events:
•
•
•
•
Transmission of the first bit to the label (TxBegin Event) and bit TStartTxBegin is 1
Transmission of the last bit to the label (TxEnd Event) and bit TStartTxEnd is 1
The counter module decrements down to zero and bit TAutoRestart is 1
Bit TStartNow is set to 1 (by the µ-Processor)
Note: Every start-event re-loads the timer from the TimerReload Register. Thus, the timer unit is re-triggered.
The timer can be configured to stop with one of the following events:
•
•
•
•
Reception of the first valid bit from the label (RxBegin Event)and bit TStopRxBegin is set to 1
Reception of the last bit from the label (RxEnd event) and bit TStopRxEnd is set to 1
The counter module has decremented down to zero and bit TAutoRestart is set to 0
Bit TStopNow is set to 1 (by the µ-Processor)
Loading a new value, e.g. zero, into the TimerReload Register does not immediately influence the counter,
since the TimerReload Register affects the counter units content only with the next start-event. Thus, the
TimerReload Register may be changed even if the timer unit is already counting. The consequence of
changing the TimerReload Register will be visible after the next start-event.
If the counter is stopped by setting bit TStopNow, no TimerIRq is signalled.
9.2.3
TIMER UNIT CLOCK AND PERIOD
The clock of the timer unit is derived from the 13.56 MHz chip clock via a programmable divider. The clock
selection is done with the TPreScaler Register, that defines the timer unit clock frequency according to the
following formula:
TTimerClock =
1
f TimerClock
=
2T PreScaler
13.56MHz
The possible values for the TPreScaler Register range from 0 up to 21. This results in minimum time
TTimerClock of about 74 ns up to about 150 ms.
The time period elapsed since the last start event is calculated with
TTimer =
TReLoadVal ue − TimerValue
f TimerClock
This results in a minimum time TTimer of about 74 ns up to about 40 s.
74
Preliminary
Philips Semiconductors
Product Specification Rev. 2.0 November 2001
I•CODE Reader IC
9.2.4
SL RC400
STATUS OF THE TIMER UNIT
The TRunning bit in the SecondaryStatus Register shows the timer’s current status. Any configured start
event starts the timer at the TReloadValue and changes the status flag TRunning to 1, any configured stop
event stops the timer and sets the status flag TRunning back to 0. As long as status flag TRunning is set to
1, the TimerValue Register changes with the next timer unit clock.
The actual timer unit content can be read on-the-fly via the TimerValue Register.
9.2.5
TIMESLOTPERIOD
For sending of I•CODE1-Quit-Frames it is necessary to generat a exact chronological relation to the begin of
the command frame.
Is TimeSlotPeriod > 0, with the end of command transmission the TimeSlotPeriod starst.
If there are Data in the FIFO after reaching the end of TimeSlotPeriod, these data were sent at that moment.
If the FIFO is empty nothing happens.
As long as the contend of TimeSlotPeriod is > 0 the counter for the TimeSlotPeriod will start automatically
after reaching the end.
This allows a exact time relation to the end (as well as to the beginning) of the command frame for the
generation and sending of the I•CODE1-Quit-Frames
Is TimeSlotPeriod > 0 the next Frame starts exact with the interval
TimeSlotPeriod/CoderRate
delayed after each previous Send Frame. CoderRate (see 5.2.3.5) defines the clock frequency of the coder.
If TimeSlotPeriod = 0, the send function will not be triggered automatically.
The contend of the register TimeSlotPeriod can be changed during the active mode. The modification take
effect at the next restart of the TimeSlotPeriod.
75
Preliminary
Philips Semiconductors
Product Specification Rev. 2.0 November 2001
I•CODE Reader IC
SL RC400
Example:
CoderRate = 0x05 (~52.97kHz)
For I•CODE1 standard mode the interval should be 8.458ms
->TimeSlotPeriod = CoderRate * interval = 52.97kHz * 8.458ms –1 = 447 (447 = 0x1BF)
Note: The MSB of the TimeSlotPeriod is in the SIGOUTSelect register see 5.2.5.7
Command
Quit1
Quit2
Response1
Response2
TSP1
TSP2
TimeSlotPeriod for TSP1
TimeSlotPeriod for TSP2
I•CODE1 Standard Mode
0xBF
0x1BF
I•CODE1 Fast Mode
0x5F
0x67
Note: The MSB of the TimeSlotPeriod is in the SIGOUTSelect register see 5.2.5.7
Note: It is strictly recommended that bit TxCRCEn is set to 0 (see 5.2.5.3) before the Quit-Frame is sent. If
the TxCRCEn is not set to 0 a CRC value is calculated and sent with the Quit-Frame.
To calculate the Quit value a CRC8 algorithm has to be used.
76
Preliminary
Philips Semiconductors
Product Specification Rev. 2.0 November 2001
I•CODE Reader IC
9.3
9.3.1
SL RC400
Usage of the Timer Unit
TIME-OUT- AND WATCH-DOG-COUNTER
Having started the timer by setting TReloadValue the timer unit decrements the TimerValue Register
beginning with a certain start event. If a certain stop event occurs e.g. a bit is received from the label, the
timer unit stops (no interrupt is generated).
On the other hand, if no stop event occurs, e.g. the label does not answer in the expected time, the timer unit
decrements down to zero and generates a timer interrupt request. This signals indicate the µ-Processor that
the expected event has not occurred in the given time TTimer.
9.3.2
STOP WATCH
The time TTimer between a certain start- and stop event may be measured by the µ-Processor by means of
the SL RC400 timer unit. Setting TReloadValue the timer starts to decrement. If the defined stop event
occurs the timers stops. The time between start and stop can be calculated by
∆T = (T Re load
value
− Timervalue ) * TTimer
if the timer does not decrements down to zero.
9.3.3
PROGRAMMABLE ONE-SHOT TIMER
The µ-Processor starts the timer unit and waits for the timer interrupt. After the specified time TTimer the
interrupt will occur (TautoRestart = 0).
9.3.4
PERIODICAL TRIGGER
If the µ-Processor sets bit TautoRestart and TreloadValue not equal 0, it will generate an interrupt request
periodically after every TTimer.
77
Preliminary
Philips Semiconductors
Product Specification Rev. 2.0 November 2001
I•CODE Reader IC
9.4
SL RC400
Register Overview Timer Unit
The following table shows the related flags of the Timer Unit in alphabetic order.
Flags
Register
Address
TAutoRestart
TimerClock
0x2A, bit 5
TimerValue
TimerValue
0x0C, bits 7-0
TimerReloadValue
TimerReload
0x2C, bits 7-0
TPreScaler
TimerClock
0x2A, bits 4-0
TRunning
SecondaryStatus
0x05, bit 7
TStartNow
Control
0x09, bit 1
TStartTxBegin
TimerControl
0x2B, bit 0
TStartTxEnd
TimerControl
0x2B, bit 1
TStopNow
Control
0x09, bit 2
TStopRxBegin
TimerControl
0x2B, bit 2
TStopRxEnd
TimerControl
0x2B, bit 3
Table 9-1 Registers associated with the Timer Unit
78
Preliminary
Philips Semiconductors
Product Specification Rev. 2.0 November 2001
I•CODE Reader IC
10
SL RC400
POWER REDUCTION MODES
10.1 Hard Power Down
A Hard Power Down is enabled with HIGH on pin RSTPD. This turns off all internal current sinks including
the oscillator. All digital input buffers are separated from the input pads and defined internally (except pin
RSTPD itself). The output pins are frozen at a certain value.
This is shown in the following table:
SYMBOL
PIN
TYPE
DESCRIPTION
OSCIN
1
I
Not separated from input, pulled to AVSS
IRQ
2
O
High impedance
RFU
3
I
Separated from Input
SIGOUT
4
O
LOW
TX1
5
O
HIGH
TX2
7
O
LOW
NWR
9
I
Separated from Input
NRD
10
I
Separated from Input
NCS
11
I
Separated from Input
D0 to D7
13 to 20
I/O
Separated from Input
ALE
21
I
Separated from Input
A0
22
I/O
Separated from Input
A1
23
I
Separated from Input
A2
24
I
Separated from Input
AUX
27
O
High impedance
RX
29
I
Not changed
VMID
30
A
Pulled to AVDD
RSTPD
31
I
Not changed
OSCOUT
32
O
HIGH
Table 10-1: Signal on Pins during Hard Power Down
10.2 Soft Power Down
This mode is immediately entered by setting bit PowerDown in the Control-Register. All internal current sinks
are switched off (including the oscillator buffer).
Different from the Hard Power Down Mode, the digital input buffers are not separated from the input pads but
keep their functionality. The digital output pins do not change their state.
After resetting bit PowerDown in the Control-Register it needs 512 clocks until the Soft Power Down mode is
left. This is indicated by the PowerDown bit itself. Resetting it does not immediately clear it, but it is cleared
automatically by the SL RC400 when the Soft Power Down Mode is left.
Note: If the internal oscillator is used, you have to take into account that it is supplied by AVDD and it will
take a certain time tosc until the oscillator is stable.
79
Preliminary
Philips Semiconductors
Product Specification Rev. 2.0 November 2001
I•CODE Reader IC
SL RC400
10.3 Stand By Mode
This mode is immediately entered by setting bit StandBy in the Control-Register. All internal current sinks are
switched off (including the internal digital clock buffer but except the oscillator buffer).
Different from the Hard Power Down Mode, the digital input buffers are not separated from the input pads but
keep their functionality. The digital output pins do not change their state.
Different from the Soft Power Down Mode, the oscillator does not need time to wake up.
After resetting bit StandBy in the Control-Register it needs 4 clocks on pin OSCIN until the Stand By Mode is
left. This is indicated by the StandBy bit itself. Resetting it does not immediately clear it, but it is cleared
automatically by the SL RC400 when the Stand By Mode is left.
10.4 Receiver Power Down
It is power saving to switch off the receiver circuit when it is not needed and switched it on again right before
data is to be received from the label. This is done automatically by setting bit RxAutoPD to 1. If it is set to 0
the receiver is continuously switched on.
80
Preliminary
Philips Semiconductors
Product Specification Rev. 2.0 November 2001
I•CODE Reader IC
11
SL RC400
START UP PHASE
The phases executed during the start up are shown in the following figure:
Start Up Phase
States
tPD
tReset
tInit
Hard Power
Down Phase
Reset Phase
Initialising
Phase
Ready
Figure 11-1: Start Up Procedure
11.1 Hard Power Down Phase
The Hard Power Down Phase is active during the following cases:
•
Power On Reset caused by power up at pin DVDD
(active while DVDD is below the digital reset threshold)
•
Power On Reset caused by power up at pin AVDD
(active while AVDD is below the analog reset threshold)
•
A HIGH level on pin RSTPD
(active while pin RSTPD is HIGH)
11.2 Reset Phase
The Reset Phase follows the Hard Power Down Phase automatically. It takes 512 clocks. During the Reset
Phase, some of the register bits are preset by hardware. The respective reset values are given in the
description of each register (see 5.2.).
Note: If the internal oscillator is used, you have to take into account that it is supplied by AVDD and that it will
take a certain time tosc until the oscillator is stable.
11.3 Initialising Phase
The Initialising Phase follows the Reset Phase automatically. It takes 128 clocks. During the Initialising
Phase the content of the E²PROM blocks 1 and 2 is copied into the registers 10hex to 2Fhex (see 6.3.).
Note: At production test, the SL RC400 is initialised with default configuration values. This reduces the
µ-Processors effort for configuring the device to a minimum.
81
Preliminary
Philips Semiconductors
Product Specification Rev. 2.0 November 2001
I•CODE Reader IC
SL RC400
11.4 Initialising the Parallel Interface-Type
For the different connections for the different µ-Processor interface types (see 4.3), a certain initialising
sequence shall be applied to enable a proper µ-Processor interface type detection and to synchronise the
µ-Processor’s and the SL RC400’s Start Up.
During the whole Start Up Phase, the Command value reads as 3Fhex . At the end of the Initialising Phase the
SL RC400 enters the Idle Command automatically. Consequently the Command value changes to 00hex .
To ensure proper detection of the µ-Processor interface, the following sequence shall be executed:
•
Read from the Command-Register until the six bit register value for Command is 00hex .
The internal initialisation phase is now completed and the SL RC400 is ready to be controlled.
•
Write the value 80hex to the Page-Register to initialise the µ-Processor interface.
•
Read the Command-Register. If its value is 00hex the µ-Processor interface initialisation was
successful.
After interface initialisation, the linear addressing mode can be activated by writing 0x00 to the page
register(s).
82
Preliminary
Philips Semiconductors
Product Specification Rev. 2.0 November 2001
I•CODE Reader IC
12
SL RC400
OSCILLATOR CIRCUITRY
SL RC400
OSCOUT
OSCIN
13.56 MHz
15 pF
15 pF
Figure 12-1: Quartz Connection
The clock applied to the SL RC400 acts as time basis for the coder and decoder of the synchronous system.
Therefore stability of clock the frequency is an important factor for proper performance. To obtain highest
performance, clock jitter has to be as small as possible. This is best achieved by using the internal oscillator
buffer with the recommended circuitry. If an external clock source is used, the clock signal has to be applied
to pin OSCIN. In this case special care for clock duty cycle and clock jitter is needed and the clock quality
has to be verified. It needs to be in accordance with the specifications in chapter 19.5.3.
Remark: It is recommend not to use an external clock source.
83
Preliminary
Philips Semiconductors
Product Specification Rev. 2.0 November 2001
I•CODE Reader IC
13
SL RC400
TRANSMITTER PINS TX1 AND TX2
The signal delivered on TX1 and TX2 is the 13.56 MHz carrier frequency modulated by an envelope signal. It
can be used to drive an antenna directly, using a few passive components for matching and filtering (see
chapter 17). For that, the output circuitry is designed with an very low impedance source resistance. The
signal of TX1 and TX2 can be controlled via the TxControl Register.
13.1 Configuration of TX1 and TX2
The configuration possibilities of TX1 are described in the table below:
Register Configuration in TxControl
Envelope
Signal on TX1
0
X
LOW (GND)
1
0
13.56 MHz carrier frequenzy modulated
1
1
13.56 MHz carrier frequenzy
TX1RFEn
Table 13-1: Configurations of Pin TX1
The configuration possibilities of TX2 are described in the table below:
Register Configuration in TxControl
Envelope
Signal on TX2
X
LOW (GND)
0
13.56 MHz carrier frequenzy modulated
1
13.56 MHz carrier frequenzy
0
13.56 MHz carrier frequenzy modulated,
180° phase shift relative to TX1
1
13.56 MHz carrier frequenzy,
180° phase shift relative to TX1
0
X
13.56 MHz carrier frequenzy
1
X
13.56 MHz carrier frequenzy,
180° phase shift relative to TX1
TX2RFEn
TX2CW
InvTX2
0
X
X
0
0
1
1
1
Table 13-2: Configurations of Pin TX2
13.2 Operating Distance versus Power Consumption
The user has the possibility to find a trade-off between maximum achievable operating distance and power
consumption by using different antenna matching circuits as described in 17.3.1 and/or by varying the supply
voltage at the antenna driver supply pin TVDD.
84
Preliminary
Philips Semiconductors
Product Specification Rev. 2.0 November 2001
I•CODE Reader IC
SL RC400
13.2.1 ANTENNA DRIVER OUTPUT SOURCE RESISTANCE
The output source conductance of TX1 and TX2 for driving a HIGH level may be adjusted via the value
GsCfgCW in the CwConductance Register in the range from about 1 up to 100 Ohm. The values given are
relative to the reference resistance Rs rel, that is measured during production test and stored in the SL RC400
E²PROM. It can be obtained from the Product Information Field (see chapter 6.2).
The electrical specification can be found in chapter 19.4.3.
13.2.1.1 Source Resistance Table
GsConfCW
EXPGsConfCW
MANT GsConfCW
Rs rel
GsConfCW
EXPGsConfCW
MANT GsConfCW
Rs rel
0
0
0
8
24
1
8
0,0652
16
1
0
8
25
1
9
0,0580
32
2
0
8
37
2
5
0,0541
48
3
0
8
26
1
A
0,0522
1
0
1
1,0000
27
1
B
0,0474
17
1
1
0,5217
51
3
3
0,0467
2
0
2
0,5000
38
2
6
0,0450
3
0
3
0,3333
28
1
C
0,0435
33
2
1
0,2703
29
1
D
0,0401
18
1
2
0,2609
39
2
7
0,0386
4
0
4
0,2500
30
1
E
0,0373
5
0
5
0,2000
52
3
4
0,0350
19
1
3
0,1739
31
1
F
0,0348
6
0
6
0,1667
40
2
8
0,0338
7
0
7
0,1429
41
2
9
0,0300
49
3
1
0,1402
53
3
5
0,0280
34
2
2
0,1351
42
2
A
0,0270
20
1
4
0,1304
43
2
B
0,0246
8
0
8
0,1250
54
3
6
0,0234
9
0
9
0,1111
44
2
C
0,0225
21
1
5
0,1043
45
2
D
0,0208
10
0
A
0,1000
55
3
7
0,0200
11
0
B
0,0909
46
2
E
0,0193
35
2
3
0,0901
47
2
F
0,0180
22
1
6
0,0870
56
3
8
0,0175
12
0
C
0,0833
57
3
9
0,0156
13
0
D
0,0769
58
3
A
0,0140
23
1
7
0,0745
59
3
B
0,0127
14
0
E
0,0714
60
3
C
0,0117
50
3
2
0,0701
61
3
D
0,0108
36
2
4
0,0676
62
3
E
0,0100
15
0
F
0,0667
63
3
F
0,0093
Table 13-3: Source Resistance of n-Channel Driver Transistor of TX1 and TX2 vs. GsConfCW
85
Preliminary
Philips Semiconductors
Product Specification Rev. 2.0 November 2001
I•CODE Reader IC
SL RC400
13.2.1.2 Formula for the Source Resistance
The relative resistance Rs rel is about
Rs rel =
1
MANTGsConfCW ⋅ ( 77
)
40
EXPGsConfCW
13.2.1.3 Calculating the Effective Source Resistance
13.2.1.3.1 Wiring Resistance
Wiring and bonding adds a constant offset to the driver resistance, that is relevant if TX1 and TX2 are
switched to low impedance.
Rs wire,TX 1 ≈ 500 mΩ
13.2.1.3.2 Effective Resistance
The source resistances of the driver transistors found in the Product Information Field (see 6.2) are
measured at production test with GsModCW set to 01hex . To get the driver resistance for a specific value set
in GsModCW the following formula may be used:
Rs x = (Rs ref , max, n − Rs wire,TX 1 ) ⋅ Rs rel + Rs wire,TX 1 .
86
Preliminary
Philips Semiconductors
Product Specification Rev. 2.0 November 2001
I•CODE Reader IC
SL RC400
13.3 Changing the Modulation Index
The following table shows the modulation index, if a 50 ohm antenna is used and GsCfgCW is set to 0x3F.
To change the modulation index the GsCfgMod register has to be changed similar as the GsCfgCW register.
GsCfgMod
rel. resistance
Mod. index
GsCfgMod
Rrel(during modulation) Rant=50Ω
rel. resistance
Mod. index
Rrel(during modulation) Rant=50Ω
0x00
Infite
0x18
0,065
4,15%
0x10
Infite
0x19
0,058
3,63%
0x20
Infite
0x25
0,054
3,35%
0x30
Infite
0x1A
0,052
3,22%
0x01
1,000
43,45%
0x1B
0,047
2,87%
0x11
0,522
28,44%
0x33
0,047
2,82%
0x02
0,500
27,57%
0x26
0,045
2,69%
0x03
0,333
20,08%
0x1C
0,043
2,58%
0x21
0,270
16,83%
0x1D
0,040
2,33%
0x12
0,261
16,33%
0x27
0,039
2,22%
0x04
0,250
15,73%
0x1E
0,037
2,12%
0x05
0,200
12,88%
0x34
0,035
1,95%
0x13
0,174
11,32%
0x1F
0,035
1,93%
0x06
0,167
10,88%
0x28
0,034
1,86%
0x07
0,143
9,38%
0x29
0,030
1,58%
0x31
0,140
9,21%
0x35
0,028
1,43%
0x22
0,135
8,89%
0x2A
0,027
1,35%
0x14
0,130
8,59%
0x2B
0,025
1,17%
0x08
0,125
8,23%
0x36
0,023
1,08%
0x09
0,111
7,32%
0x2C
0,023
1,01%
0x15
0,104
6,86%
0x2D
0,021
0,88%
0x0A
0,100
6,57%
0x37
0,020
0,82%
0x0B
0,091
5,95%
0x2E
0,019
0,77%
0x23
0,090
5,89%
0x2F
0,018
0,67%
0x16
0,087
5,68%
0x38
0,018
0,63%
0x0C
0,083
5,43%
0x39
0,016
0,48%
0x0D
0,077
4,98%
0x3A
0,014
0,36%
0x17
0,075
4,81%
0x3B
0,013
0,26%
0x0E
0,071
4,59%
0x3C
0,012
0,18%
0x32
0,070
4,50%
0x3D
0,011
0,11%
0x24
0,068
4,32%
0x3E
0,010
0,05%
0x0F
0,067
4,26%
0x3F
0,009
0,00%
Note: If the output source conductance (GsCfgCW) has been changed GsCfgMod must also be changed to
get the same modulation index.
87
Preliminary
Philips Semiconductors
Product Specification Rev. 2.0 November 2001
I•CODE Reader IC
SL RC400
13.4 Pulse Width
The envelope carries the information of the data signal, that shall be transmitted to the label. This is done by
coding the data signal according to the 1 out of 256, RZ or 1 out of 4 code. Furthermore, each pause of the
coded signal again is coded as a pulse of certain length. The width of this pulse can be adjusted by means of
the ModWidth Register. The pulse length is calculated by
TPulse = 2
ModWidth + 1
fC
where fc = 13.56MHz.
88
Preliminary
Philips Semiconductors
Product Specification Rev. 2.0 November 2001
I•CODE Reader IC
14
SL RC400
RECEIVER CIRCUITRY
14.1 General
The SL RC400 employs an integrated quadrature-demodulation circuit which extracts the sub-carrier signal
from the 13.56 MHz ASK-modulated signal applied to pin RX. The quadrature-demodulator uses two
different clocks, Q- and I-clock, with a phase shift of 90° between them. Both resulting subcarrier signals are
amplified, filtered and forwarded to the correlation circuitry. The correlation results are evaluated, digitised
and passed to the digital circuitry.
For all processing units various adjustments can be made to obtain optimum performance.
14.2 Block Diagram
Figure 14-1 shows the block diagram of the receiver circuitry. The receiving process includes several steps.
First the quadrature demodulation of the carrier signal of 13.56 MHz is done. To achieve an optimum in
performance an automatic clock Q calibration is recommended (see 14.3.1). The demodulated signal is
amplified by an adjustable amplifier. A correlation circuit calculates the degree of similarity between the
expected and the received signal. The bit phase register allows to align the position of the correlation
intervals with the bit grid of the received signal. In the evaluation and digitizer circuitry the valid bits are
detected and the digital results are send to the FIFO register. Several tuning steps in this circuit are possible.
ClockQDelay[4:0]
ClockQCalib
ClockQ180°
BitPhase[7:0]
CollLevel[3:0]
Gain[1:0]
MinLevel[3:0]
RcvClkSelI
RxWait[7:0]
I to Q
Conversion
clock
I-clock
Q-clock
s_valid
RX
13.56 MHz
Demodulator
Correlation
Circuitry
Evaluation and Digitizer
Circuitry
s_data
s_coll
s_clock
VRxFollQ
VRxFollI
VRxAmpQ
VRxAmpI
VCorrNI
VCorrDI
VCorrNQ
VCorrDQ
VEvalR
VEvalL
to
TestAna
OutSel
Figure 14-1: Block Diagram of Receiver Circuitry
The user may observe the signal on its way through the receiver as shown in the block diagram above. One
signal at a time may be routed to pin AUX using the TestAnaSelect-Register as described in 18.3.
89
Preliminary
Philips Semiconductors
Product Specification Rev. 2.0 November 2001
I•CODE Reader IC
SL RC400
14.3 Putting the Receiver into Operation
In general, the default settings programmed into the Start Up Initialisation File are suitable to use the
SL RC400 for data communication with I•CODE labels. However, in some environments specific user
settings may achieve better performance.
14.3.1 AUTOMATIC CLOCK-Q CALIBRATION
The quadrature demodulation concept of the receiver generates a phase signal I-clock and a 90° shifted
quadrature signal Q-clock. To achieve an optimum demodulator performance, the Q- and the I-clock have to
have a difference in phase of 90°. After the reset phase of the SL RC400, a calibration procedure is done
automatically. It is possible to have an automatic calibration done at the ending of each Transceive
command. To do so, the ClkQCalib bit has to be configured to a value of 0.
Configuring this bit to a constant value of 1 disables all automatic calibrations except the one after the reset
sequence.
It is also possible to initiate one automatic calibration by software. This is done with a 0 to 1 transition of bit
ClkQCalib.
The details:
calibration impulse
from reset sequence
a rising edge initiates
a clock Q calibration
calibration impulse
from ending of
TRANSEIVE command
the ClkQCalib bit
Note: The duration of the automatic clock Q calibration is at most 65 oscillator periods which is approx.
4,8µs.
The value of ClkQDelay is proportional to the phase shift between the Q- and the I-clock. The status flag
ClkQ180Deg shows, that the phase shift between the Q- and the I-clock is greater than 180°.
Notes:
•
The startup configuration file enables an automatically Q-clock calibration after the reset.
•
While ClkQCalib is 1, no automatic calibration is done. Therefore leaving this bit 1 can be used to
permanently disable the automatic calibration.
•
It is possible to write data to ClkQDelay via the µ-Processor. The aim could be a disabling of the
automatic calibration and to pre-set the delay by software. But notice, that configuring the delay value by
software requires that bit ClkQCalib has already been set to 1 before and that a time interval of at least
4.8µs has elapsed since then. Each delay value must be written with the ClkQCalib bit set to 1. If
ClkQCalib is 0 the configured delay value will be overwritten by the next interval automatic calibration.
90
Preliminary
Philips Semiconductors
Product Specification Rev. 2.0 November 2001
I•CODE Reader IC
SL RC400
14.3.2 AMPLIFIER
The demodulated signal has to be amplified with the variable amplifier to achieve the best performance. The
gain of the amplifiers can be adjusted by means of the register bits Gain[1:0]. The following gain factors are
selectable:
Register Setting
Gain Factor
(Simulation Results)
Gain Factor [dB]
(Simulation Results)
0
22
26.9
1
35
30.9
2
82
38.3
3
130
42.2
Table 14-1: Gain Factors for the Internal Amplifier
91
Preliminary
Philips Semiconductors
Product Specification Rev. 2.0 November 2001
I•CODE Reader IC
SL RC400
14.3.3 CORRELATION CIRCUITRY
The correlation circuitry calculates the degree of matching between the received and an expected signal.
The output is a measure for the amplitude of the expected signal in the received signal. This is done for both,
the Q- and the I-channel. The correlator delivers two outputs for each of the two input channels, resulting in
four output signals in total.
For optimum performance, the correlation circuitry needs the phase information for the signal coming from
the label. This information has to be defined by the µ-Processor by means of the register BitPhase[7:0]. This
value defines the phase relation between the transmitter and receiver clock in multiples of
tBitPhase = 1/13.56 MHz.
14.3.4 EVALUATION AND DIGITIZER CIRCUITRY
For each bit-half of the Manchester coded signal the correlation results are evaluated. The evaluation and
digitizer circuit decides from the signal strengths of both bit-halves, whether the current bit is valid, and, if it is
valid, the value of the bit itself or whether the current bit-interval contains a collision.
To do this in an optimum way, the user may select the following levels:
•
MinLevel: Defines the minimum signal strength of the stronger bit-half’s signal for being considered valid.
•
CollLevel: Defines the minimum signal strength that has to be exceeded by the weaker half-bit of the
Manchester-coded signal to generate a bit-collision. If the signal’s strength is below this value, a 1 and 0
can be determined unequivocally.
CollLevel defines the minimum signal strength relative to the amplitude of the stronger half-bit.
After transmission of data, the label is not allowed to send its response before a certain time period, called
frame guard time in the standard ISO 15693 (similar to I•CODE1). The length of this time period after
transmission shall be set in the RxWait-Register. The RxWait-Register defines when the receiver is switched
on after data transmission to the label in multiples of one bit-duration.
If register bit RcvClkSelI is set to 1, the I-clock is used to clock the correlator and evaluation circuits. If set to
0, the Q-clock is used.
Note: It is recommended to use the Q-clock.
92
Preliminary
Philips Semiconductors
Product Specification Rev. 2.0 November 2001
I•CODE Reader IC
15
SL RC400
SERIAL SIGNAL SWITCH
15.1 General
Two main blocks are implemented in the SL RC400. A digital circuitry, comprising state machines, coder and
decoder logic and so on and an analog circuitry with the modulator and antenna drivers, receiver and
amplification circuitry. The interface between these two blocks can be configured in the way, that the
interfacing signals may be routed to the pin SIGOUT.
15.2 Block Diagram
Figure 15-1 describes the serial signal switches. Three different switches are implemented in the serial signal
switch in order to use the SL RC400 in different configurations.
The serial signal switch may also be used during the design In phase or for test purposes to check the
transmitted and received data. Chapter 18.2, describes analog test signals as well as measurements at the
serial signal switch.
0
0
Serial Data Out
1 out of 256
or
RZ or
1 out of 4
1
1
Envelope
2
RFU
3
Tx1
Modulator
Driver
Tx2
2
Modulator
Source
(Part of)
Serial Data Processing
Carrier
Demodulator
Rx
3
SigOut
Select
Manchester
1
1
0
0
Decoder
Source
Subcarrier
Demodulator
RFU
Manchester with Subcarrier
5
3 RFU
2
RFU
Transmitt NRZ
4
2 RFU
6
Envelope
Manchester Out
3
Manchester
Decoder
2
Serial Data In
0
1 Internal
7
0
(Part of)
Analog Circuitry
1
0
Digital Test Signal
SignalTo
SigOut
Serial Signal Switch
SIGOut
Figure 15-1: Serial Signal Switch
The following chapters describe the relevant registers used to configure and control the serial signal switch.
93
Preliminary
Philips Semiconductors
Product Specification Rev. 2.0 November 2001
I•CODE Reader IC
SL RC400
15.3 Registers Relevant for the Serial Signal Switch
The flags DecoderSource define the input signal for the internal Manchester decoder in the following way:
DecoderSource
Input Signal for Decoder
0
Constant 0
1
Output of the analog part. This is the default configuration.
2
RFU
3
RFU
Table 15-1: Values for DecoderSource
ModulatorSource defines the signal that modulates the transmitted 13.56 MHz carrier frequenzy. The
modulated signal drives the pins TX1 and TX2.
ModulatorSource
Input Signal for Modulator
0
Constant 0 (carrier frequency off at pin TX1 and TX2).
1
Constant 1 (continuous carrier frequency delivered at pin TX1 and TX2).
2
Modulation signal (envelope) from the internal coder. This is the default
configuration.
3
RFU
Table 15-2: Values for ModulatorSource
SIGOUTSelect defines the input signal for the internal Manchester decoder in the following way:
SIGOUTSelect
Signal Routed to Pin SIGOUT
0
Constant 0
1
Constant 1
2
Modulation signal (envelope) from the internal coder.
3
Serial data stream that is to be transmitted
(same as for SIGOUTSelect = 2, but not coded by the “selected” pulse coder yet).
4
Output signal of the receiver circuit (label modulation signal regenerated
and delayed)
5
Output signal of the sub-carrier demodulator (Manchester-coded label signal)
6
RFU
7
RFU
Table 15-3: Values for SIGOUTselect
Note: To use SIGOUTSelect, the value of test signal control bit SignalToSIGOUT has to be 0.
94
Preliminary
Philips Semiconductors
Product Specification Rev. 2.0 November 2001
I•CODE Reader IC
16
SL RC400
SL RC400 COMMAND SET
16.1 General Description
The SL RC400 behaviour is determined by an internal state machine that is capable to perform a certain set
of commands. These commands are started by writing the according command-code to the CommandRegister.
Arguments and/or data necessary to process a command are exchanged via the FIFO buffer.
16.2 General Behaviour
•
Each command, that needs a data stream (or data byte stream) as input will immediately process the
data it finds in the FIFO buffer.
•
Each command, that needs a certain number of arguments will start processing only when it has
received the correct number of arguments via the FIFO buffer.
•
The FIFO buffer is not cleared automatically at command start. Therefore, it is also possible to write the
command arguments and/or the data bytes into the FIFO buffer and start the command afterwards.
•
Each command (except the StartUp-Command) may be interrupted by the µ-Processor by writing a new
command code into the Command-Register e.g.: the Idle-Command.
95
Preliminary
Philips Semiconductors
Product Specification Rev. 2.0 November 2001
I•CODE Reader IC
SL RC400
16.3 SL RC400 Commands Overview
Command
Code
Action
Arguments and Data
passed via FIFO
Returned Data
via FIFO
see
Chapter
Runs the Reset- and Initialisation
Phase.
StartUp
3Fhex
Note: This command can not be
activated by software, but only by a
Power-On or Hard Reset
-
-
16.3.2
Idle
00hex
No action: cancels current command
execution.
-
-
16.3.3
Transmit
1Ahex
Transmits data from the FIFO buffer to
the label.
-
16.4.1
Data Stream
16.4.2
Data Stream
16.4.3
-
16.5
Data Bytes
16.5.2
Data Stream
Activates Receiver Circuitry.
Receive
16hex
Note: Before the receiver actually
starts, the state machine waits until the
time configured in the register RcvWait
has passed.
-
Note: This command may be used for
test purposes only, since there is no
timing relation to the TransmitCommand.
Transmits data from FIFO buffer to the
label and activates automatically the
receiver after transmission.
Transceive
1Ehex
Note: Before the receiver actually
Data Stream
starts, the SL RC400 waits until the
time configured in the register RcvWait
has passed.
Note: This command is the
combination of Transmit and Receive
WriteE2
01hex
Gets data from FIFO buffer and writes
it to the internal E²PROM.
Start Address LSB
Start Address MSB
Data Byte Stream
ReadE2
03hex
Reads data from the internal E²PROM
and puts it into the FIFO buffer.
Start Address LSB
Start Address MSB
Number of Data Bytes
LoadConfig
07hex
Reads data from E²PROM and
initialises the SL RC400 registers.
Start Address LSB
Start Address MSB
-
16.6.1
Data Byte-Stream
-
16.5
Activates the CRC-Coprocessor.
CalcCRC
12hex
Note: The result of the CRC
calculation can be read from the
registers CRCResultLSB and
CRCResultMSB
Table 16-1: SL RC400 Command Overview
96
Preliminary
Philips Semiconductors
Product Specification Rev. 2.0 November 2001
I•CODE Reader IC
SL RC400
16.3.1 BASIC STATES
16.3.2 STARTUP COMMAND 3FHEX
Command
Action
Code hex
Arguments and Data
Returned Data
-
-
Runs the Reset- and Initialisation Phase
StartUp
3F
Note: This command can not be activated by
software, but only by a Power-On or Hard
Reset
The StartUp-Command runs the Reset- and Initialisation Phase. It does not need or return any data. It can
not be activated by the µ-Processor but is started automatically after one of the following events:
• Power On Reset caused by power up at Pin DVDD
• Power On Reset caused by power up at Pin AVDD
• Negative Edge at Pin RSTPD
The Reset-Phase defines certain register bits by an asynchronous reset. The Initialisation-Phase defines
certain registers with values taken from the E²PROM.
When the StartUp-Command has finished, the Idle-Command is entered automatically.
Notes:
•
The µ-Processor must not write to the SL RC400 as long as the SL RC400 is busy executing the
StartUp-Command. To ensure this, the µ-Processor shall poll for the Idle-Command to determine the
end of the Initialisation Phase (see also chapter 11.4).
•
As long as the StartUp-Command is active, only reading from page 0 of the SL RC400 is possible.
•
The StartUp-Command can not be interrupted by the µ-Processor.
16.3.3 IDLE COMMAND 00HEX
Command
Code hex
Action
Arguments and Data
Returned Data
Idle
00
No action: cancels current command execution
-
-
The Idle-Command switches the SL RC400 to its inactive state. In this Idle-state it waits for the next
command. It does not need or return any data. The device automatically enters the Idle-state when a
command finishes. In this case the SL RC400 simultaneously initiates an interrupt request by setting bit
IdleIRq. Triggered by the µ-Processor, the Idle-Command may be used to stop execution of all other
commands (except the StartUp Command). In that case no IdleIRq is generated.
Remark: Stopping a command with the Idle Command does not clear the FIFO buffer content.
97
Preliminary
Philips Semiconductors
Product Specification Rev. 2.0 November 2001
I•CODE Reader IC
SL RC400
16.4 Commands for Label Communication
The SL RC400 is a fully ISO 15693 and I•CODE1 compliant reader IC. The following chapter describe the
command set for label communication in general.
16.4.1 TRANSMIT COMMAND 1A HEX
Command
Code hex
Transmit
1A
Action
Arguments and Data
Transmits data from FIFO buffer to the label
Data Stream
Returned Data
-
The Transmit-Command takes data from the FIFO buffer and forwards it to the transmitter. It does not return
any data. The Transmit-Command can only be started by the µ-Processor.
16.4.1.1 Working with the Transmit Command
To transmit data one of the following sequences may be used:
1.
All data, that shall be transmitted to the label is written to the FIFO while the Idle-Command is active.
After that, the command code for the Transmit-Command is written to the Command-Register.
Note: This is possible for transmission of data with a length of up to 64 bytes.
2.
The command code for the Transmit-Command is written to Command-Register first. Since no data is
available in the FIFO, the command is only enabled but transmission is not triggered yet.
Data transmission really starts with the first data byte written to the FIFO. To generate a continuous data
stream on the RF-interface, the µ-Processor has to put the next data bytes to the FIFO in time.
Note: This allows transmission of data of any length but requires that data is available in the FIFO in
time.
3.
A part of the data, that shall be transmit to the label is written to the FIFO while the Idle-Command is
active. After that, the command code for the Transmit-Command is written to the Command-Register.
While the Transmit-Command is active, the µ-Processor may feed further data to the FIFO, causing the
transmitter to append it to the transmitted data stream.
Note: This enables transmission of data of any length but requires that data is available in the FIFO in
time.
When the transmitter requests the next data byte to keep the data stream on the RF-interface continuous but
the FIFO buffer is empty, the Transmit-Command automatically terminates. This causes the internal state
machine to change its state from Transmit to Idle.
If data transmission to the label is finished, the SL RC400 sets the flag TxIRq to signal it to the µ-Processor.
Remark: If the µ-Processor overwrites the transmit code in the Command-Register with the Idle-Command or
any other command, transmission stops immediately with the next clock cycle. This may produce output
signals that are not according to the standard ISO 15693 or the I•CODE1 protocol.
98
Preliminary
Philips Semiconductors
Product Specification Rev. 2.0 November 2001
I•CODE Reader IC
SL RC400
16.4.1.2 RF-Channel Redundancy and Framing
Each transmitted ISO 15693 frame consists of a SOF (start of frame) pattern, followed by the data stream
and is closed by an EOF (end of frame) pattern. All I•CODE1 command frames consists of a START PULSE
followed by the data stream. The I•CODE1 commands have a fix length and no EOF is needed. These
different phases of the transmit sequence may be monitored by watching ModemState of PrimaryStatusRegister (see 16.4.4).
Depending on the setting of bit TxCRCEn in the ChannelRedundancy-Register a CRC is calculated and
appended to the data stream. The CRC is calculated according the settings in the ChannelRedundancy
Register.
16.4.1.3 Transmission of Frames with more than 64 Bytes
To generate frames with more than 64 bytes, the µ-Processor has to write data into the FIFO buffer while the
Transmit Command is active. The state machine checks the FIFO status when it starts transmitting the last
bit of the actual data stream (the check time is marked below with arrows).
TxLastBits
TxLastBits = 0
FIFO Length
0x01
0x00
FIFO empty
TxData
Bit7 Bit0
Bit7 Bit0
Bit7
Check FIFO empty
Accept Further Data
Figure 16-1: Timing for Transmitting Byte Oriented Frames
As long as the internal signal ‘Accept Further Data’ is 1 further data may be loaded into the FIFO. The
SL RC400 appends this data to the data stream transmitted via the RF-interface.
If the internal signal ‘Accept Further Data’ is 0 the transmission will terminate. All data written into the FIFO
buffer after ‘Accept Further Data’ went 0 will not be transmitted anymore, but remain in the FIFO buffer.
99
Preliminary
Philips Semiconductors
Product Specification Rev. 2.0 November 2001
I•CODE Reader IC
SL RC400
16.4.2 RECEIVE COMMAND 16HEX
Command
Code hex
Receive
16
Action
Activates Receiver Circuitry
Arguments and Data
Returned Data
-
Data Stream
The Receive-Command activates the receiver circuitry. All data received from the RF interface is returned via
the FIFO buffer. The Receive-Command can be started either by the µ-Processor or automatically during
execution of the Transceive-Command.
Note: This command may be used for test purposes only, since there is no timing relation to the TransmitCommand.
16.4.2.1 Working with the Receive Command
After starting the Receive Command the internal state machine decrements the value set in the RxWaitRegister with every bit-clock. From 3 down to 1 the analog receiver circuitry is prepared and activated. When
the counter reaches 0, the receiver starts monitoring the incoming signal at the RF-interface. If the signal
strength reaches a level higher than the value set in the MinLevel-Register it finally starts decoding. The
decoder stops, if no more signal can be detected on the receiver input pin Rx. The decoder indicates
termination of operation by setting bit RxIRq.
The different phases of the receive sequence may be monitored by watching ModemState of the
PrimaryStatus-Register (see 16.4.4).
Note: Since the counter values from 3 to 0 are necessary to initialise the analog receiver circuitry the
minimum value for RxWait is 3.
16.4.2.2 RF-Channel Redundancy and Framing
For ISO 15693 the decoder expects a SOF pattern at the beginning of each data stream. If a SOF is
detected, it activates the serial to parallel converter and gathers the incoming data bits. For I•CODE1 the
decoder do not expects a SOF pattern at the beginning of each data stream. It activates the serial to parallel
converter with the first received bit of the data. Every completed byte is forwarded to the FIFO. If an EOF
pattern (ISO15693) is detected or the signal strength falls below MinLevel set in the RxThreshold Register,
the receiver and the decoder stop, the Idle-Command is entered and an appropriate response for the µProcessor is generated (interrupt request activated, status flags set).
If bit RxCRCEn in the ChannelRedundancy Register is set a CRC block is expected. The CRC block may be
one byte or two bytes according to bit CRC8 in the ChannelRedundancy Register.
Remark: The received CRC block is not forwarded to the FIFO buffer if it is correct. This is realised by
shifting the incoming data bytes through an internal buffer of either one or two bytes (depending on the
defined CRC). The CRC block remains in this internal buffer. As a consequence all data bytes are available
in the FIFO buffer one or two bytes delayed.
If the CRC fails all received bytes are forwarded to the FIFO buffer (including the faulty CRC itself).
100
Preliminary
Philips Semiconductors
Product Specification Rev. 2.0 November 2001
I•CODE Reader IC
SL RC400
16.4.2.3 Collision Detection
If more than one label is within the RF-field during the label selection phase, they will respond
simultaneously. The SL RC400 supports the algorithm defined in ISO 15693 as well as the I•CODE1 anticollision algorithm to resolve data-collisions of label serial numbers by doing the so-called anti-collision
procedure. The basis for this is the ability to detect bit-collisions.
Bit-collision detection is supported by the used bit-coding scheme, namely the Manchester-coding. If in the
first and second half-bit of a bit a sub-carrier modulation is detected, instead of forwarding a 1 or a 0 a bit
collision will be signalled. To distinguish a 1 or 0-bit from a bit-collision, the SL RC400 uses the setting of
CollLevel. If the amplitude of the half-bit with smaller amplitude is larger than defined by CollLevel, the
SL RC400 indicates a bit-collision.
If a bit-collision is detected, the error flag CollErr is set.
Independent from the detected collision the receiver continues receiving the incoming data stream. In case of
a bit-collision, the decoder forwards 1 at the collision position.
Note: As an exception, if bit ZeroAfterColl is set, all bits received after the first bit-collision are forced to zero,
regardless whether a bit-collision or an unequivocal state has been detected. This feature eases for the
software to carry out the anti-collision procedure defined in ISO 15693.
When the first bit collision in a frame is detected, the bit position of this collision is stored in the CollPos
Register.
The collision position follows the table below:
Collision in Bit
Value of CollPos
SOF
0
LSBit of LSByte
1
…
…
MSBit of LSByte
8
LSBit of second Byte
9
…
…
MSBit of second Byte
16
LSBit of third Byte
17
…
…
Table 16-2: Returned Values for Bit Collision Positions
If a collision is detected in the SOF a frame error is reported and no data is forwarded to the FIFO buffer. In
this case the receiver continues to monitor the incoming signal and generates the correct notifications to the
µ-Processor when the ending of the faulty input stream is detected. This helps the µ-Processor to determine
the time when it is allowed next to send anything to the label.
101
Preliminary
Philips Semiconductors
Product Specification Rev. 2.0 November 2001
I•CODE Reader IC
SL RC400
16.4.2.4 Communication Errors
The following table shows which event causes the setting of error flags:
Cause
Bit, that is set
Received data did not start with a SOF pattern.
FramingErr
The CRC block is not equal the expected value.
CRCErr
The received data is shorter than the CRC block.
CRCErr
A collision is detected.
CollErr
Table 16-3: Communication Error Table
16.4.3 TRANSCEIVE COMMAND 1E HEX
Command
Code hex
Transceive
1E
Action
Arguments and Data
Transmits data from FIFO buffer to the label
and then activates automatically the receiver
Data Stream
Returned Data
Data Stream
The Transceive-Command first executes the Transmit-Command (see 16.4.1) and then automatically starts
the Receive-Command (see 16.4.2). All data that shall be transmitted is forwarded via the FIFO buffer and all
data received is returned via the FIFO buffer. The Transceive-Command can be started only by the
µ-Processor.
Note: To adjust the timing relation between transmitting and receiving, the RxWait Register is used to define
the time delay from the last bit transmitted until the receiver is activated. Furthermore, the BitPhase Register
determines the phase-shift between the transmitter and the receiver clock.
16.4.4 STATES OF THE LABEL COMMUNICATION
The actual state of the transmitter and receiver state machine can be fetched from ModemState in the
PrimaryStatus Register.
The assignment of ModemState to the internal action is shown in the following table:
ModemState
Name of State
Description
000
Idle
001
TxSOF
Transmitting the ‘Start Of Frame’ Pattern
010
TxData
Transmitting data from the FIFO buffer (or redundancy check bits)
011
TxEOF
Transmitting the ‘End Of Frame’ Pattern
Neither the transmitter nor the receiver is in operation,
since none of them is started or the transmitter has not got input data
GoToRx1
Intermediate state passed, when receiver starts
GoToRx2
Intermediate state passed, when receiver finishes
101
PrepareRx
Waiting until the time period selected in the RxWait Register has expired
110
AwaitingRx
Receiver activated; Awaiting an input signal at pin Rx
111
Receiving
Receiving data
100
Table 16-4: Meaning of ModemState
102
Preliminary
Philips Semiconductors
Product Specification Rev. 2.0 November 2001
I•CODE Reader IC
SL RC400
16.4.5 STATE DIAGRAM FOR THE LABEL COMMUNICATION
Command =
(Transmit OR
Receive OR
Transceive)
Idle
(000)
F
Co IFO
(Tr mm not e
an an m
sm d = pty
it O
AN
R
D
Tra
ns
ce
ive
)
Co
m
Re man
ce d =
ive
GoToRx1
(100)
TxSOF
(001)
next bit clock
SOF transmitted
TxData
(010)
PrepareRx
(101)
RxMultiple = 1 &&
TimeSlotPeriod > 0 &&
TimeSlot Trigger &&
Data in FIFO
RxWaitCounter
=0
Data transmitted
TxEOF
(011)
AwaitingRx
(110)
Signal Strength >
MinLevel
EOF transmitted AND
Command = Transceive
Receiving
(111)
EOF transmitted AND
Command = Transmit
Frame Received
End of Receive frame &&
RxMultiple = 0 &&
TimeSlotPeriod = 0
Set
CommandRegister = Idle
(000)
GoToRx2
(100)
RxMultiple = 0 &&
TimeSlotPeriod > 0 &&
TimeSlot Trigger &&
Data in FIFO
Idle
(000)
Preparing to
send the Quit
value
Remark: I•CODE1 do not have a SOF and a EOF
103
Preliminary
Philips Semiconductors
Product Specification Rev. 2.0 November 2001
I•CODE Reader IC
SL RC400
16.5 Commands to Access the E²PROM
16.5.1 WRITEE2 COMMAND 01HEX
16.5.1.1 Overview
Command
Code hex
WriteE2
01
Arguments and
Data passed via
FIFO
Action
Get data from FIFO buffer and write it to the E²PROM
Start Address LSB
Start Address MSB
Data Byte Stream
Returned
Data via
FIFO
-
The WriteE2-Command interprets the first two bytes in the FIFO buffer as E²PROM starting byte-address.
Any further bytes are interpreted as data bytes and are programmed into the E²PROM, starting from the
given E²PROM starting byte-address. This command does not return any data.
The WriteE2-Command can only be started by the µ-Processor. It will not stop automatically but has to be
stopped explicitly by the µ-Processor by issuing the Idle-Command.
16.5.1.2 Programming Process
2
One byte up to 16 byte can be programmed into the E PROM in one programming cycle. The time needed
will be in any case about 5.8ms.
The state machine copies all data bytes prepared in the FIFO buffer to the E²PROM input buffer. The internal
E²PROM input buffer is 16 byte long which is equal the block size of the E²PROM. A programming cycle is
started either if the last position of the E²PROM input buffer is written or if the last byte of the FIFO buffer has
been fetched.
As long as there are unprocessed bytes in the FIFO buffer or the E²PROM programming cycle still is in
progress, the flag E2Ready is 0. If all data from the FIFO buffer are programmed into the E²PROM, the flag
E2Ready is set to1. Together with the rising edge of E2Ready the interrupt request flag TxIRq indicates a 1.
This may be used to generate an interrupt when programming of all data is finished.
After the E2Ready bit is set to 1, the WriteE2-Command may be stopped by the µ-Processor by issuing the
Idle-Command.
Important: The WriteE2-Command must not be stopped by starting another command before the E2Ready
flag is set to 1. Otherwise the content of the currently processed E²PROM block will not be defined or in
worst case the SL RC400 functionality is in-reversibly reduced.
104
Preliminary
Philips Semiconductors
Product Specification Rev. 2.0 November 2001
I•CODE Reader IC
SL RC400
16.5.1.3 Timing Diagram
The following diagram shows programming of 5 bytes into the E²PROM:
t prg,del
NWrite
Data
WriteE2
command active
E²PROM
Programming
Write Adr
E2 LSB
Adr
MSB
Byte0
Byte1
Byte2
Byte3
Idle
Cmd
Byte4
t prog
t prog
Programming Byte0
Programming Byte1, Byte2, and Byte3
t prog
Programming Byte4
E2Ready
TxIRq
Figure 16-3: Timing Diagram for E²PROM programming
Explanation: It is assumed, that the SL RC400 finds and reads Byte 0 before the µ-Processor is able to write
Byte 1 (t prog,del = 300 ns). This causes the SL RC400 to start the programming cycle, which needs about
tprog = 2.9 ms. In the meantime the µ-Processor stores Byte 1 to Byte 4 to the FIFO buffer. Assuming, that the
E²PROM starting byte-address is e.g. 4Chex then Byte 0 is stored exactly there. The SL RC400 copies the
following data bytes into the E²PROM input buffer. Copying Byte 3, it detects, that this data byte has to be
programmed at the E²PROM byte-address 4Fhex . Since this is the end of the memory block, the SL RC400
automatically starts a programming cycle. In the next turn, Byte 4 will be programmed at the E²PROM byteaddress 50hex . Since this is the last data byte, the flags (E2Ready and TxIRq) that indicate the end of the
E²PROM programming activity will be set.
Although all data has been programmed into the E2PROM, the SL RC400 stays in the WriteE2-Command.
Writing further data to the FIFO would lead to further E²PROM programming, continuing at the E²PROM
byte-address 51hex . The command is stopped using the Idle-Command.
16.5.1.4 Error Flags for the WriteE2 Command
Programming is inhibited for the E²PROM blocks 0 (E²PROM’s byte-address 00hex to 0Fhex ). Programming to
these addresses sets the flag AccessErr. No programming cycle is started (for the E²PROM memory
organisation refer to chapter 6.). It is strictly recommended to use only the described E²PROM address area.
105
Preliminary
Philips Semiconductors
Product Specification Rev. 2.0 November 2001
I•CODE Reader IC
SL RC400
16.5.2 READE2 COMMAND 03HEX
16.5.2.1 Overview
Command
Code hex
ReadE2
03
Action
Arguments
Reads data from E²PROM and puts it to the
FIFO buffer
Start Address LSB
Start Address MSB
Number of Data Bytes
Returned Data
Data Bytes
The ReadE2-Command interprets the first two bytes found in the FIFO buffer as E²PROM starting
byte-address. The next byte specifies the number of data bytes that shall be returned.
When all three argument-bytes are available in the FIFO buffer, the specified number of data bytes is copied
from the E²PROM into the FIFO buffer, starting from the given E²PROM starting byte-address.
The ReadE2-Command can be triggered only by the µ-Processor. It stops automatically when all data has
been delivered.
Note: It is strictly recommended to use only the described E²PROM address area.
106
Preliminary
Philips Semiconductors
Product Specification Rev. 2.0 November 2001
I•CODE Reader IC
SL RC400
16.6 Diverse Commands
16.6.1 LOADCONFIG COMMAND 07HEX
16.6.1.1 Overview
Command
Code hex
LoadConfig
07
Action
Arguments and Data
Reads data from E²PROM and initialises the
registers
Returned Data
Start Address LSB
Start Address MSB
-
The LoadConfig-Command interprets the first two bytes found in the FIFO buffer as E²PROM starting
byte-address. When the two argument-bytes are available in the FIFO buffer, 32 bytes from the E²PROM are
copied into the SL RC400 control and configuration registers, starting at the given E²PROM starting
byte-address. The LoadConfig-Command can only be started by the µ-Processor. It stops automatically
when all relevant registers have been copied.
Note: It is strictly recommended to use only the described E²PROM address area.
16.6.1.2 Register Assignment
The 32 bytes of E²PROM content, beginning with the E²PROM starting byte-address, is written to the
SL RC400 register 10hex up to register 2Fhex (for the E²PROM memory organisation see 6).
Note: The procedure for the register assignment is the same as it is for the Start Up Initialisation (see 11.3).
The difference is, that the E²PROM starting byte-address for the Start Up Initialisation is fixed to 10hex
(Block 1, Byte 0). With the LoadConfig-Command it can be chosen.
16.6.1.3 Relevant Error Flags for the LoadConfig-Command
Valid E²PROM starting byte-addresses are in the range from 10hex up to 60hex .
16.6.2 CALCCRC COMMAND 12HEX
16.6.2.1 Overview
Command
Code hex
CalcCRC
12
Action
Arguments and Data
Activates the CRC-Coprocessor
Data Byte-Stream
Returned Data
-
The CalcCRC-Command takes all data from the FIFO buffer as input bytes for the CRC-Coprocessor. All
data stored in the FIFO buffer before the command is started will be processed. This command does not
return any data via the FIFO buffer, but the content of the CRC-register can be read back via the
CRCResultLSB-register and the CRCResultMSB-register. The CalcCRC-Command can only be started by
the µ-Processor. It does not stop automatically but has to be stopped explicitly by the µ-Processor with the
Idle-Command. If the FIFO buffer is empty, the CalcCRC-Command waits for further input from the FIFO
buffer.
Note: Do not use this command to calculate the Quit value for I?CODE1 tag’s because this would terminate
the Transceive command.
107
Preliminary
Philips Semiconductors
Product Specification Rev. 2.0 November 2001
I•CODE Reader IC
SL RC400
16.6.2.2 CRC-Coprocessor Settings
For the CRC-Coprocessor the following parameters may be configured:
Parameter
Value
Bit
Register
CRC Register Length
8 Bit or 16 Bit CRC
CRC8
ChannelRedundancy
CRC Algorithm
1 = Algorithm according ISO 15693 or according
ISO/IEC3309
CRC3309
ChannelRedundancy
0 = algorithm according to I•CODE1
Bit-Processing Direction
Shift the MSBit or LSBit first into the CRCregister
CRCMSBFirst
ChannelRedundancy
CRC Preset Value
Any
CRCPresetLSB,
CRCPresetMSB
CRCPresetLSB,
CRCPresetMSB
Table 16-5: CRC-Coprocessor Parameters
x8 + x4 + x3 + x2 + 1.
16
12
5
The CRC polynomial for the 16-bit CRC is fixed to x + x + x + 1 .
The CRC polynomial for the 8-bit CRC is fixed to
16.6.2.3 Status Flags of the CRC-Coprocessor
The status flag CRCReady indicates, that the CRC-Coprocessor has finished processing of all data bytes
found in the FIFO buffer. With the CRCReady flag setting to 1, an interrupt is requested with TxIRq being set.
This supports interrupt driven usage of the CRC-Coprocessor.
When CRCReady and TxIRq are set to 1, respectively, the content of the CRCResultLSB- and
CRCResultMSB-register and the flag CRCErr is valid.
The CRCResultLSB- and CRCResultMSB-register hold the content of the CRC register, the CRCErr flag
indicates CRC validity for the processed data.
16.7 Error Handling during Command Execution
If any error is detected during command execution, this is shown by setting the status flag Err in the
PrimaryStatus Register. For information about the cause of the error, the µ-Processor may evaluate the
status flags in the ErrorFlag Register.
Error Flag of the ErrorFlag Register
Related to Command
AccessError
WriteE2, ReadE2, LoadConfig
FIFOOvl
Not related to a command
CRCErr
Receive, Transceive, CalcCRC
FramingErr
Receive, Transceive
CollErr
Receive, Transceive
Table 16-6: Error Flags Overview
108
Preliminary
Philips Semiconductors
Product Specification Rev. 2.0 November 2001
I•CODE Reader IC
17
SL RC400
TYPICAL APPLICATION
17.1 Circuit Diagram
The figure below shows a typical application, where the antenna is direct connected to the SL RC400:
DVDD
DVDD
Reset
AVDD
RSTPD
AVDD
TVDD
TVDD
C1
L0
µProcessor
Data Bus
IRQ
TX1
µProcessor Bus
Control Lines
C0
C2a
C0
C2b
TVSS
IRQ
SL RC400
TX2
L0
C1
R1'
RX
R1
DVSS
OSCIN
OSCOUT AVSS
C3
VMID
R2
C4
100 nF
13.56 MHz
15 pF
15 pF
Figure 17-1: Circuit Diagram for Application Example: Direct Matched Antenna
The matching circuit consists of an EMC low pass filter, a receiving circuit, an antenna matching circuit and
the antenna itself.
For more detailed information about designing and tuning an antenna please refer to chapter 17.3.1.
109
Preliminary
Philips Semiconductors
Product Specification Rev. 2.0 November 2001
I•CODE Reader IC
SL RC400
17.2 Circuit Description
17.2.1 EMC LOW PASS FILTER
The I•CODE system operates at a frequency of 13.56 MHz. This frequency is generated by a quartz
oscillator to clock the SL RC400 and is also the basis for driving the antenna with the 13.56 MHz carrier
frequenzy. This will not only cause emitted power at 13.56 MHz but will also emit power at higher harmonics.
The international EMC regulations define the amplitude of the emitted power in a broad frequency range.
Thus, an appropriate filtering of the output signal is necessary to fulfil these regulations.
A multi-layer board it is strongly recommended to implement a low pass filter as shown in the circuit above.
The low pass filter consists of the components L0 and C0. The values are given in table below.
Note: To achieve best performance all components shall have at least the quality of the recommended ones.
17.2.2 RECEIVING CIRCUIT
The internal receiving part of the SL RC400 uses a concept that benefits from both side-bands of the subcarrier load modulation of the label response. It is recommended to use the internally generated VMID
potential as the input potential of pin RX. To provide a stable reference voltage a capacitance C4 to ground
has to be connected to VMID. The receiving part of the reader needs a voltage divider connected between
the RX and the VMID pin. Additionally, it is recommended to use a series capacitance between the antenna
coil and the voltage divider. The circuit diagram above shows the recommended receiving circuit. The
receiving circuit consists of the components R1, R2, C3 and C4. The values are given in the table below.
Components
Value
Remark
L0
1 µH ± 5%
Magnetic shielded e.g. TDK NL322522T-1R0J
C0
2 * 68 pF ± 2%
NP0 material, Value depending on the antenna
inductance
R1’
3.9 kΩ ± 1%
R1
560 Ω ± 1%
R2
820Ω ± 1%
C3
1 nF ± 2%
NP0 material
Table 17-1: Values for the EMC- Filter and Receiving Circuit
Note: It is recommended not to use X7R material for the capacitors.
17.3 Calculation of the Antenna Coil Inductance
The precise calculation of the antenna coils inductance is not practicable but the inductance can be
estimated using the following formula. We recommend designing an antenna either with a circular or
rectangular shape.
  l 
 1, 8
L1 [nH ] = 2 ⋅ l 1 [cm ] ⋅  ln 1  − K  N 1
  D1 

l1.............. Length of the conductor loop of one turn
D1 ............ Diameter of the wire or width of the PCB conductor respectively
K ............. Antenna Shape Factor (K = 1,07 for circular antennas and K = 1,47 for square antennas)
N1 ............ Number of turns
ln ............. Natural logarithm function
110
Preliminary
Philips Semiconductors
Product Specification Rev. 2.0 November 2001
I•CODE Reader IC
SL RC400
17.3.1 IMPEDANCE MATCHING FOR DIRECTLY MATCHED ANTENNAS
To design a matching circuit for a directly matched antenna we recommend to use the circuit shown in 17.1.
The values for the capacitors C1 and C2a, C2b depend on the antenna’s electrical properties and
environmental influences.
The values for the capacitors shown in the table below are guidelines. In fact, they are used as starting
values for the tuning procedure.
Antenna Coil
Inductance [µH]
C1 [pF]
C2a [pF]
C2b [pF]
0.8
27
270
330
0.9
27
270
270
1.0
27
220
270
1.1
27
180 || 22
220
1.2
27
180
180 || 22
1.3
27
180
180
1.4
27
150
180
1.5
27
150
150
1.6
27
120 || 10
150
1.7
27
120
150
1.8
27
120
120
Table 17-2: Capacitance Values for the Matching Circuit
However, for optimum performance, the accurate values have to be found by the tuning, variation of the
capacitance’s C2x and C1.
The above table assumes a stray capacitance of 15 pF of the antenna coil. The capacitors C1 and C2s
should have a NP0 dielectric with a tolerance of +/-2 %.
The actual values of the antenna inductance and capacitance depend on various parameters like:
•
•
•
•
•
antenna construction (Type of PCB)
thickness of conductor
distance between the windings
shielding layer
metal or ferrite in the near environment
111
Preliminary
Philips Semiconductors
Product Specification Rev. 2.0 November 2001
I•CODE Reader IC
18
SL RC400
TEST SIGNALS
18.1 General
The SL RC400 allows different kind of signal measurements. These measurements can be used to check the
internally generated and received signals using the possibilities of the serial signal switch as described in
chapter 15.
Furthermore, with the SL RC400 the user may select internal analog signals to measure them at pin AUX
and internal digital signals to observe them on pin SIGOUT by register selections. These measurements can
be helpful during the design-in phase to optimise the receiver’s behaviour or for test purpose.
18.2 Measurements Using the Serial Signal Switch
Using the serial signal switch at pin SIGOUT the user may observe data send to the label or data received
from the label. The following tables give an overview of the different signals available.
SignalToSIGOUT
SIGOUTSelect
Signal routed to SIGOUT pin
0
0
LOW
0
1
HIGH
0
2
Envelope
0
3
Transmit NRZ
0
4
Manchester with Subcarrier
0
5
Manchester
0
6
RFU
0
7
RFU
1
X
Digital Test signal
Table 18-1 Signal routed to SIGOUT pin
112
Preliminary
Philips Semiconductors
Product Specification Rev. 2.0 November 2001
I•CODE Reader IC
SL RC400
18.3 Analog Test-Signals
The analog test signals may be routed to pin AUX by selecting them with the register bits TestAnaOutSel.
Value
Signal Name
Description
0
Vmid
1
Vbandgap
Internal reference voltage generated by the band gap.
2
VRxFollI
Output signal from the demodulator using the I-clock.
3
VRxFollQ
Output signal from the demodulator using the Q-clock.
4
VRxAmpI
I-channel subcarrier signal amplified and filtered.
5
VRxAmpQ
Q-channel subcarrier signal amplified and filtered.
6
VCorrNI
Output signal of N-channel correlator fed by the I-channel subcarrier
signal.
7
VCorrNQ
Output signal of N-channel correlator fed by the Q-channel subcarrier
signal.
8
VCorrDI
Output signal of D-channel correlator fed by the I-channel subcarrier
signal.
9
VCorrDQ
Output signal of D-channel correlator fed by the Q-channel subcarrier
signal.
A
VEvalL
Evaluation signal from the left half bit.
B
VEvalR
Evaluation signal from the right half bit.
C
VTemp
Temperature voltage derived from band gap.
D
RFU
Reserved for future use
E
RFU
Reserved for future use
F
RFU
Reserved for future use
Voltage at internal node Vmid
Table 18-2: Analog Test Signal Selection
113
Preliminary
Philips Semiconductors
Product Specification Rev. 2.0 November 2001
I•CODE Reader IC
SL RC400
18.4 Digital Test-Signals
Digital test signals may be routed to pin SIGOUT by setting bit SignalToSIGOUT to 1. A digital test signal
may be selected via the register bits TestDigiSignalSel in Register TestDigiSelect.
The signals selected by a certain TestDigiSignalSel setting is shown in the table below:
TestDigiSignalSel
Signal Name
Description
F4 hex
s_data
Data received from the label.
E4hex
s_valid
Shows with 1, that the signals s_data and s_coll are valid.
D4hex
s_coll
Shows with 1, that a collision has been detected in the current bit.
C4hex
s_clock
Internal serial clock: during transmission, this is the coder-clock and during
reception this is the receiver clock.
B5hex
rd_sync
Internal synchronised read signal (derived from the parallel µ-Processor
interface).
A5hex
wr_sync
Internal synchronised write signal (derived from the parallel µ-Processor
interface).
96hex
int_clock
Internal 13.56 MHz clock.
00hex
no test signal
output as defined by SIGOUTSelect are routed to pin SIGOUT.
Table 18-3: Digital Test Signal Selection
If no test signals are used, the value for the TestDigiSel-Register shall be 00hex .
Note: All other values of TestDigiSignalSel are for production test purposes only.
114
Preliminary
Philips Semiconductors
Product Specification Rev. 2.0 November 2001
I•CODE Reader IC
SL RC400
18.5 Examples of Analog- and Digital Test Signals
Fig. 17 shows the answer of an I•CODE1 Label IC to a unselected read command using the Qclock
receiving path.
RX –Reference is given to show the Manchester modulated signal at the RX pin. This signal is demodulated
and amplified in the receiver circuitry VRXAmpQ shows the amplified side band signal having used the QClock for demodulation. The signals VCorrDQ and VCorrNQ generated in the correlation circuitry are
evaluated and digitised in the evaluation and digitizer circuitry. VEvalR and VEvalL show the evaluation
signal of the right and left half bit. Finally, the digital test-signal S_data shows the received data which is
send to the internal digital circuit and S_valid indicates that the received data stream is valid.
Receiving path Q-Clock
VrxAmpQ
VcorrDQ
VcorrNQ
VevalR
VevalL
Sdata
50µsec/Dev.
SValid
500µsec/Dev.
Figure 17. Receiving path Q-Clock
115
Preliminary
Philips Semiconductors
Product Specification Rev. 2.0 November 2001
I•CODE Reader IC
SL RC400
116
Preliminary
Philips Semiconductors
Product Specification Rev. 2.0 November 2001
I•CODE Reader IC
19
SL RC400
ELECTRICAL CHARACTERISTICS
19.1 Absolute Maximum Ratings
SYMBOL
PARAMETER
MIN
MAX
UNIT
Ambient or Storage Temperature Range
-40
+150
°C
DC Supply Voltages
-0.5
6
V
Vin,abs
Absolute voltage on any digital pin to DVSS
-0.5
DVDD + 0.5
V
VRX,abs
Absolute voltage on RX pin to AVSS
-0.5
AVDD + 0.5
V
Tamb,abs
DVDD
AVDD
TVDD
Table 19-1: Absolute Maximum Ratings
19.2 Operating Condition Range
SYMBOL
PARAMETER
Tamb
Ambient Temperature
DVDD
Digital Supply Voltage
AVDD
Analog Supply Voltage
TVDD
Transmitter Supply Voltage
CONDITIONS
MIN
TYP
MAX
UNIT
-
-25
+25
+85
°C
4.5
5.0
5.5
V
4.5
5.0
5.5
V
3.0
5.0
5.5
V
TYP
MAX
UNIT
DVSS = AVSS = TVSS = 0V
Table 19-2: Operating Condition Range
19.3 Current Consumption
SYMBOL
IDVDD
IAVDD
PARAMETER
CONDITIONS
Digital Supply Current
Analog Supply Current
MIN
Idle Command
6
mA
Stand By Mode
3
mA
Soft Power Down Mode
800
µA
Hard Power Down Mode
1
µA
Idle Command, Receiver On
29
mA
Idle Command, Receiver Off
10
mA
Stand By Mode
8
mA
Soft Power Down Mode
1
µA
Hard Power Down Mode
1
µA
Continuous Wave
ITVDD
Transmitter Supply Current
150
mA
TX1 and TX2 unconnected
TX1RFEn, TX2RFEn = 1
4.5
9
mA
TX1 and TX2 unconnected
TX1RFEn, TX2RFEn = 0
65
130
µA
Table 19-3: Current Consumption
117
Preliminary
Philips Semiconductors
Product Specification Rev. 2.0 November 2001
I•CODE Reader IC
SL RC400
19.4 Pin Characteristics
19.4.1 INPUT PIN CHARACTERISTICS
Pins D0 to D7, A0 and A1 have TTL input characteristics and behave as defined in the following table.
SYMBOL
PARAMETER
ILeak
VT
CONDITIONS
MIN
MAX
UNIT
Input Leakage Current
-1.0
+1.0
µA
Threshold
0.8
2.0
V
Table 19-4: Standard Input Pin Characteristics
The digital input pins NCS, NWR, NRD, ALE and A2 have Schmitt-Trigger characteristics, and behave as
defined in the following table.
SYMBOL
PARAMETER
ILeak
CONDITIONS
MIN
MAX
UNIT
Input Leakage Current
-1.0
+1.0
µA
VT+
Positive-Going Threshold
1.4
2.0
V
VT-
Negative-Going Threshold
0.8
1.3
V
Table 19-5: Schmitt-Trigger Input Pin Characteristics
Pin RSTPD has Schmitt-Trigger CMOS characteristics. In addition, it is internally filtered with an RC-lowpass filter, which causes a relevant propagation delay for the reset signal:
SYMBOL
PARAMETER
ILeak
CONDITIONS
MIN
MAX
UNIT
Input Leakage Current
-1.0
+1.0
µA
VT+
Positive-Going Threshold
0.65 DVDD
0.75 DVDD
V
VT-
Negative-Going Threshold
0.25 DVDD
0.4 DVDD
V
tRSTPD,p
Propagation Delay
20
µs
MAX
UNIT
15
pF
Table 19-6: RSTPD Input Pin Characteristics
The analog input pin RX has the following input capacitance:
SYMBOL
PARAMETER
CRX
Input Capacitance
CONDITIONS
MIN
Table 19-7: RX Input Capacitance
118
Preliminary
Philips Semiconductors
Product Specification Rev. 2.0 November 2001
I•CODE Reader IC
SL RC400
19.4.2 DIGITAL OUTPUT PIN CHARACTERISTICS
Pins D0 to D7, SIGOUT and IRQ have TTL output characteristics and behave as defined in the following
table.
SYMBOL
PARAMETER
VOH
Output Voltage HIGH
VOL
IO
Output Voltage LOW
Output Current source or sink
CONDITIONS
MIN
TYP
MAX
UNIT
DVDD = 5 V, IOH = -1 mA
2.4
4.9
V
DVDD = 5 V, IOH = -10 mA
2.4
4.2
V
DVDD = 5 V, IOL = 1 mA
25
400
mV
DVDD = 5 V, IOL = 10 mA
250
400
mV
10
mA
DVDD = 5 V
Table 19-8:Digital Output Pin Characteristics
Note: IRQ pin may also be configured as open collector. In that case the values for VOH do not apply.
19.4.3 ANTENNA DRIVER OUTPUT PIN CHARACTERISTICS
The source conductance of the antenna driver pins TX1 and TX2 for driving the HIGH level can be
configured via GsCfgCW in the CwConductance Register, while their source conductance for driving the
LOW level is constant.
For the default configuration, the output characteristic is specified below:
SYMBOL
PARAMETER
VOH
Output Voltage HIGH
VOL
ITX
Output Voltage LOW
Transmitter Output Current
CONDITIONS
MIN
TYP
MAX
UNIT
TVDD = 5.0 V, I OL = 20 mA
4.97
V
TVDD = 5.0 V, I OL = 100 mA
4.85
V
TVDD = 5.0 V, I OL = 20 mA
30
mV
TVDD = 5.0 V, I OL = 100 mA
150
mV
Continuous Wave
200
mApeak
Table 19-9:Antenna Driver Output Pin Characteristics
119
Preliminary
Philips Semiconductors
Product Specification Rev. 2.0 November 2001
I•CODE Reader IC
SL RC400
19.5 AC Electrical Characteristics
19.5.1 AC SYMBOLS
Each timing symbol has five characters. The first character is always 't' for time. The other characters
indicate the name of a signal or the logic state of that signal (depending on position):
Designation:
Signal:
Designation:
Logic Level:
A
address
H
HIGH
D
data
L
LOW
W
NWR or nWait
Z
high impedance
R
NRD or R/NW or nWrite
X
any level or data
L
ALE or AS
V
any valid signal or data
C
NCS
S
NDS or nDStrb and nAStrb
Example: tAVLL = time for address valid to ALE low
120
Preliminary
Philips Semiconductors
Product Specification Rev. 2.0 November 2001
I•CODE Reader IC
SL RC400
19.5.2 AC OPERATING SPECIFICATION
19.5.2.1 Bus Timing for Separated Read/Write Strobe
SYMBOL
PARAMETER
MIN
tLHLL
tAVLL
ALE pulse width
Multiplexed Address Bus valid to ALE low (Address Set Up Time)
20
15
MAX
UNIT
ns
ns
tLLAX
Multiplexed Address Bus valid after ALE low (Address Hold Time)
8
ns
tLLWL
tCLWL
ALE low to NWR, NRD low
NCS low to NRD, NWR low
15
0
ns
ns
tWHCH
NRD, NWR high to NCS high
0
tRLDV
tRHDZ
NRD low to DATA valid
NRD high to DATA high impedance
65
20
ns
ns
tWLDV
NWR low to DATA valid
35
ns
tWHDX
tWLWH
DATA hold after NWR high (Data Hold Time)
NRD, NWR pulse width
8
65
ns
ns
tAVWL
Separated Address Bus valid to NRD, NWR low (Set Up Time)
30
ns
tWHAX
tWHWL
Separated Address Bus valid after NWR high (Hold Time)
period between sequenced read / write accesses
8
150
ns
ns
ns
Table 19-10: Timing Specification for Separated Read/Write Strobe
tLHLL
ALE
tCLWL
tWHCH
NCS
tLLWL
tWHWL
tWLWH
tWHWL
NWR
NRD
tAVLL
D0 ... D7
tWLDV
tRLDV
tLLAX
Multiplexed Addressbus
tWHDX
tRHDZ
D0 ... D7
A0 ... A2
tAVWL
t WHAX
Separated Addressbus
A0 ... A2
A0 ... A2
Figure 19-1: Timing Diagram for Separated Read/Write Strobe
Note: For separated address and data bus the signal ALE is not relevant and the multiplexed addresses on the data bus
don’t care.
For the multiplexed address and data bus the address lines A0 to A2 have to be connected as described in 4.3.
121
Preliminary
Philips Semiconductors
Product Specification Rev. 2.0 November 2001
I•CODE Reader IC
SL RC400
19.5.2.2 Bus Timing for Common Read/Write Strobe
SYMBOL
tLHLL
tAVLL
tLLAX
tLLSL
tCLSL
tSHCH
tSLDV,R
tSHDZ
tSLDV,W
tSHDX
tSHRX
tSLSH
tAVSL
tSHAX
tSHSL
tRVSL
PARAMETER
AS pulse width
Multiplexed Address Bus valid to AS low (Address Set Up Time)
Multiplexed Address Bus valid after AS low (Address Hold Time)
AS low to NDS low
NCS low to NDS low
NDS high to NCS high
NDS low to DATA valid (for read cycle)
NDS low to DATA high impedance (read cycle)
NDS low to DATA valid (for write cycle)
DATA hold after NDS high (write cycle, Hold Time)
R/NW hold after NDS high
NDS pulse width
Separated Address Bus valid to NDS low (Hold Time)
Separated Address Bus valid after NDS high (Set Up Time)
period between sequenced read/write accesses
R/NW valid to NDS low
MIN
20
15
8
15
0
0
MAX
65
20
35
8
8
65
30
8
150
8
UNIT
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
Table 19-11: Timing Specification for Common Read/Write Strobe
tLHLL
ALE
tCLSL
tSHCH
NCS
tRVSL
tSHRX
R/NW
tLLSL
tSHSL
tSLSH
tSHSL
NDS
tAVLL
D0 ... D7
tSLDV,R
tSLDV,W
tLLAX
Multiplexed Addressbus
tSHDX
tSHDZ
D0 ... D7
A0 ... A2
tAVSL
tSHAX
Separated Addressbus
A0 ... A2
A0 ... A2
Figure 19-2: Timing Diagram for Common Read/Write Strobe
Note: For separated address and data bus the signal ALE is not relevant and the multiplexed addresses on the data bus don’t
care. For the multiplexed address and data bus the address lines A0 to A2 have to be connected as described in 4.3.
122
Preliminary
Philips Semiconductors
Product Specification Rev. 2.0 November 2001
I•CODE Reader IC
SL RC400
19.5.2.3 Bus Timing for EPP
SYMBOL
tLLLH
PARAMETER
nAStrb pulse width
MIN
20
MAX
UNIT
ns
tAVLH
Multiplexed Address Bus valid to nAStrb high (Set Up Time)
15
ns
tLHAX
tCLSL
Multiplexed Address Bus valid after nAStrb high (Hold Time)
NCS low to nDStrb low
8
0
ns
ns
tSHCH
nDStrb high to NCS high
0
ns
tSLDV,R
tSHDZ
nDStrb low to DATA valid (read cycle)
nDStrb low to DATA high impedance (read cycle)
65
20
ns
ns
35
ns
tSLDV,W
nDStrb low to DATA valid (write cycle, Set up Time)
tSHDX
tSHRX
DATA hold after nDStrb high (write cycle, Hold Time)
nWrite hold after nDStrb high
8
8
ns
ns
tSLSH
nDStrb pulse width
65
ns
tRVSL
tSLWH
nWrite valid to nDStrb low
nDStrb low to nWait high
8
tSHWL
nDStrb high to nWait low
75
ns
ns
75
ns
Table 19-12: Timing Specification for Common Read/Write Strobe
t CLSL
tSHCH
NCS
tRVSL
tSHRX
nWrite
t SLSH
nDStrb
nAStrb
t SLDV,R
t SLDV,W
tSHDX
tSHDZ
D0 ... D7
A0 ... A7
D0 ... D7
tSLWH
tSHWL
nWait
Figure 19-3: Timing Diagram for Common Read/Write Strobe
Remark: The figure does not distinguish between the Address Write Cycle and a Data Write Cycle. Take in
account, that timings for the Address Write and Data Write Cycle different. For the EPP-Mode the address
lines A0 to A2 have to be connected as described in 4.3.
123
Preliminary
Philips Semiconductors
Product Specification Rev. 2.0 November 2001
I•CODE Reader IC
SL RC400
19.5.3 CLOCK FREQUENCY
The clock input is pin 1, OSCIN.
PARAMETER
SYMBOL
Clock Frequency (checked by the clock filter)
fOSCIN
Duty Cycle of Clock Frequency
dFEC
Jitter of Clock Edges
tjitter
MIN
TYP
MAX
13.56
40
50
UNIT
MHz
60
%
10
ps
The clock applied to the SL RC400 acts as time basis for the coder and decoder of the synchronous system.
Therefore stability of clock frequency is an important factor for proper performance. To obtain highest
performance, clock jitter shall be as small as possible. This is best achieved using the internal oscillator
buffer with the recommended circuitry (see 12).
124
Preliminary
Philips Semiconductors
Product Specification Rev. 2.0 November 2001
I•CODE Reader IC
20
SL RC400
2
E PROM CHARACTERISTICS
The E²PROM has a size of 8x16x8 = 1.024 bit.
SYMBOL
PARAMETER
CONDITIONS
MIN
MAX
UNIT
tEEEndurance
Data Endurance
tEERetention
Data Retention
tEEErase
Erase Time
2.9
ms
tEEWrite
Write Time
2.9
ms
100.000
erase/write cycles
10
years
Tamb ≤ 55°C
Table 20-1:E²PROM Characteristics
125
Preliminary
Philips Semiconductors
Product Specification Rev. 2.0 November 2001
I•CODE Reader IC
21
SL RC400
PACKAGE OUTLINES
21.1 SO32
SO32: plastic small outline package; 32 leads; body width 7.5 mm
SOT287-1
D
E
A
X
c
y
HE
v M A
Z
17
32
Q
A2
A
(A3 )
A1
pin 1 index
θ
Lp
L
16
1
0
detail X
wM
bp
e
5
10 mm
scale
DIMENSIONS (inch dimensions are derived from the original mm dimensions)
UNIT
A
max.
A1
A2
A3
bp
c
D(1)
E (1)
e
HE
L
Lp
Q
v
w
y
Z (1)
mm
2.65
0.3
0.1
2.45
2.25
0.25
0.49
0.36
0.27
0.18
20.7
20.3
7.6
7.4
1.27
10.65
10.00
1.4
1.1
0.4
1.2
1.0
0.25
0.25
0.1
0.95
0.55
0.012 0.096
inches 0.10
0.01
0.004 0.086
0.02 0.011 0.81
0.01 0.007 0.80
0.30
0.419
0.043 0.047
0.050
0.055
0.01
0.29
0.394
0.016 0.039
0.037
0.01 0.004
0.022
θ
o
8
0o
Note
1. Plastic or metal protrusions of 0.15 mm maximum per side are not included.
OUTLINE
VERSION
REFERENCES
IEC
JEDEC
EIAJ
EUROPEAN
PROJECTION
ISSUE DATE
95-01-25
97-05-22
SOT287-1
Figure 21-1: Outline and Dimension of SL RC400 in SO32
126
Preliminary
Philips Semiconductors
Product Specification Rev. 2.0 November 2001
I•CODE Reader IC
22
SL RC400
TERMS AND ABBREVIATIONS
Designation:
Description:
µ-Processor
Micro Processor
E²PROM
Electrically Erasable Programmable Read Only Memory
EOF
End of Frame
FWT
Frame Waiting Time: maximum time delay between last bit transmitted by
the reader and first bit received from the label’s response.
I?CODE
A family of hard-wired logic contactless label ICs. The protocol of these
labels is according to I•CODE1 and ISO 15693. On top they use a fixed set
of commands.
POR
Power On Reset: triggers a reset, caused by a rising edge on a supply pin.
ROM
Read Only Memory
SOF
Start of Frame
127
Preliminary
Philips Semiconductors
Product Specification Rev. 2.0 November 2001
I•CODE Reader IC
23
SL RC400
DEFINITIONS
Data sheet status
Objective specification
This data sheet contains target or goal specifications for product development.
Preliminary specification This data sheet contains preliminary data; supplementary data may be
published later.
Product specification
This data sheet contains final product specifications.
Limiting values
Limiting values given are in accordance with the Absolute Maximum Rating System (IEC 134). Stress
above one or more of the limiting values may cause permanent damage to the device. These are stress
ratings only and operation of the device at these or at any other conditions above those given in the
Characteristics section of the specification is not implied. Exposure to limiting values for extended
periods may affect device reliability.
Application information
Where application information is given, it is advisory and does not form part of the specification.
24
LIFE SUPPORT APPLICATIONS
These products are not designed for use in life support appliances, devices, or systems where malfunction of
these products can reasonably be expected to result in personal injury. Philips customers using or selling
these products for use in such applications do so on their own risk and agree to fully indemnify Philips for
any damages resulting from such improper use or sale.
128
Preliminary
Philips Semiconductors
Product Specification Rev. 2.0 November 2001
I•CODE Reader IC
25
SL RC400
REVISION HISTORY
REVISION
DATE
CPCN
PAGE
DESCRIPTION
1.0
2.0
First published version
14.11.01
Preliminary version
Table 25-1: Document Versions Up to Revision 1.0
129
Preliminary
Philips Semiconductors - a worldwide company
Argentina: see South America
Australia: 34 Waterloo Road, NORTHRYDE, NSW 2113,
Tel. +612 9805 4455, Fax. +612 9805 4466
Austria: Computerstraße 6, A-1101 WIEN, P.O.Box 213,
Tel. +431 60 101, Fax. +431 30 101 1210
Belarus: Hotel Minsk Business Centre, Bld. 3, r.1211, Volodarski Str. 6,
220050 MINSK, Tel. +375172 200 733, Fax. +375172 200 773
Belgium: see The Netherlands
Brazil : see South America
Bulgaria: Philips Bulgaria Ltd., Energoproject, 15th floor,
51 James Bourchier Blvd., 1407 SOFIA
Tel. +3592 689 211, Fax. +3592 689 102
Canada: Philips Semiconductors/Components,
Tel. +1800 234 7381
China/Hong Kong: 501 Hong Kong Industrial Technology Centre,
72 Tat Chee Avenue, Kowloon Tong, HONG KONG,
Tel. +85223 19 7888, Fax. +85223 19 7700
Colombia: see South America
Czech Republic: see Austria
Denmark: Prags Boulevard 80, PB 1919, DK-2300 COPENHAGEN S,
Tel. +4532 88 2636, Fax. +4531 57 1949
Finland: Sinikalliontie 3, FIN-02630 ESPOO,
Tel. +3589 61 5800, Fax. +3589 61 58rfuxx
France: 4 Rue du Port-aux-Vins, BP 317, 92156 SURESNES Cedex,
Tel. +331 40 99 6161, Fax. +331 40 99 6427
Germany: Hammerbrookstraße 69, D-20097 HAMBURG,
Tel. +4940 23 53 60, Fax. +4940 23 536 300
Greece: No. 15, 25th March Street, GR 17778 TAVROS/ATHENS,
Tel. +301 4894 339/239, Fax. +301 4814 240
Hungary: see Austria
India: Philips INDIA Ltd., Shivsagar Estate, A Block, Dr. Annie Besant Rd.
Worli, MUMBAI 400018, Tel. +9122 4938 541, Fax. +9122 4938 722
Indonesia: see Singapore
Ireland: Newstead, Clonskeagh, DUBLIN 14,
Tel. +3531 7640 000, Fax. +3531 7640 200
Israel : RAPAC Electronics, 7 Kehilat Saloniki St., TEL AVIV 61180,
Tel. +9723 645 0444, Fax. +9723 649 1007
Italy: Philips Semiconductors, Piazza IV Novembre 3,
20124 MILANO, Tel. +392 6752 2531, Fax. +392 6752 2557
Japan : Philips Bldg. 13-37, Kohnan 2-chome, Minato-ku, TOKYO 108,
Tel. +813 3740 5130,Fax. +813 3740 5077
Korea: Philips House, 260-199, Itaewon-dong, Yonsan-ku, SEOUL,
Tel. +822 709 1412, Fax. +822 709 1415
Malaysia: No. 76 Jalan Universiti, 46200 PETALING JAYA, Selangor,
Tel. +60 3750 5214, Fax. +603 757 4880
Mexico : 5900 Gateway East, Suite 200, EL PASO, Texas 79905,
Tel. +9 5800 234 7381
Middle East: see Italy
Netherlands: Postbus 90050, 5600 PB EINDHOVEN, Bldg. VB,
Tel. +3140 27 82785, Fax +3140 27 88399
New Zealand: 2 Wagener Place, C.P.O. Box 1041, AUCKLand,
Tel. +649 849 4160, Fax. +649 849 7811
Norway: Box 1, Manglerud 0612, OSLO,
Tel. +4722 74 8000, Fax. +4722 74 8341
Philippines: Philips Semiconductors Philippines Inc.,
106 Valero St. Salcedo Village, P.O.Box 2108 MCC, MAKATI,
Metro MANILA, Tel. +632 816 6380, Fax. +632 817 3474
Poland: Ul. Lukiska 10, PL 04-123 WARSZWA,
Tel. +4822 612 2831, Fax. +4822 612 2327
Portugal: see Spain
Romania: see Italy
Russia: Philips Russia, Ul. Usatcheva 35A, 119048 MOSCOW,
Tel. +7095 247 9145, Fax. +7095 247 9144
Singapore: Lorong 1, Toa Payoh, SINGAPORE 1231,
Tel. +65350 2538, Fax. +65251 6500
Slovakia: see Austria
Slovenia: see Italy
South Africa: S.A. Philips Pty Ltd., 195-215 Main Road Martindale,
2092 JOHANNESBURG, P.O.Box 7430 Johannesburg 2000,
Tel. +2711 470 5911, Fax. +2711 470 5494
South America: Rua do Rocio 220, 5th floor, Suite 51,
04552-903 Sao Paulo, SAO PAULO - SP, Brazil,
Tel. +5511 821 2333, Fax. +5511 829 1849
Spain: Balmes 22, 08007 BARCELONA,
Tel. +343 301 6312, Fax. +343 301 4107
Sweden : Kottbygatan 7, Akalla, S-16485 STOCKHOLM,
Tel. +468 632 2000, Fax. +468 632 2745
Switzerland: Allmendstraße 140, CH-8027 ZÜRICH,
Tel. +411 488 2686, Fax. +411 481 7730
Taiwan : Philips Taiwan Ltd., 2330F, 66,
Chung Hsiao West Road, Sec. 1, P.O.Box 22978,
TAIPEI 100, Tel. +8862 382 4443, Fax. +8862 382 4444
Thailand: Philips Electronics (Thailand) Ltd.,
209/2 Sanpavuth-Bangna Road Prakanong, BANGKOK 10260,
Tel. +662 745 4090, Fax. +662 398 0793
Turkey: Talapasa Cad. No. 5, 80640 GÜLTEPE/ISTANBUL,
Tel. +90212 279 2770, Fax. +90212 282 6707
Ukraine: Philips Ukraine, 4 Patrice Lumumba Str., Building B, Floor 7,
252042 KIEV, Tel. +38044 264 2776, Fax. +38044 268 0461
United Kingdom: Philips Semiconductors Ltd., 276 Bath Road, Hayes,
MIDDLESEX UM3 5BX, Tel. +44181 730 5000, Fax. +44181 754 8421
United States: 811 Argues Avenue, SUNNYVALE, CA94088-3409,
Tel. +1800 234 7381
Uruguay: see South America
Vietnam: see Singapore
Yugoslavia: Philips, Trg N. Pasica 5/v, 11000 BEOGRAD,
Tel. +38111 625 344, Fax. +38111 635 777
Published by:
Philips Semiconductors Gratkorn GmbH, Mikron-Weg 1, A-8101 Gratkorn, Austria Fax: +43 3124 299 - 270
For all other countries apply to: Philips Semiconductors, Marketing & Sales Communications, Internet: http://www.semiconductors.philips.com
Building BE-p, P.O.Box 218, 5600 MD EINDHOVEN, The Netherlands, Fax: +3140 27 24825
© Philips Electronics N.V. 1997
SCB52
All rights are reserved. Reproduction in whole or in part is prohibited without the prior written consent of the copyright owner.
The information presented in this document does not form part of any quotation or contract, is believed to be accurate and reliable and may be changed
without any notice. No liability will be accepted by the publisher for any consequence of its use. Publication thereof does not convey nor imply any license
under patent- or other industrial or intellectual property rights.
Philips