W9959_04_LP_099-133_35 2/8/02 4:16 PM Page 130 LPX 40/60 ENCLOSURES EUROPE ASIA Astec House, Waterfront Business Park Merry Hill, Dudley West Midlands, DY5 1LX, UK Telephone: 44 (1384)842-211 Facsimile: 44 (1384) 843-355 17th Floor, Lu Plaza 2 Wing Yip Street Kwun Tong, Kowloon Hong Kong SAR Telephone: 852-2176-3333 Facsimile: 852-2176-3888 AMERICAS 5810 Van Allen Way Carlsbad, CA 92008 Telephone: 760-930-4600 Facsimile: 760-930-0698 Installation Notes LPX 40 and LPX 60 • Cover Enclosure Kit LPX40 will fit both the LPX4X and LPX2X power supplies. NOTES MATERIALS 1 1 6 1 1 1 1 Base Cover (top and sides perforated) M3 x 6mm screws with captive lock washer M4 nut M4 star washer For earth stud M4 spring washer Plastic insulator sheet 1. 2. 3. 4. 5. 6. 130 America’s (USA): 1-888-41-ASTEC All dimensions in inches (mm). Overall dimensions: LPX 25/40: 5.9 (150) x 3.86 (98) x 1.5 (38) LPX 60: 5.9 (150) x 3.86 (98) x 1.97 (50) Base plate has three sets of customer mountings: a. Bottom mounting (4x) M3 inserts, max. screw penetration 3mm; b. Bottom mounting (2x) 4mm clear holes plus 2 keyways (see keyway detail); c. Side mountings (2x) M3 inserts, max. screw penetration 6mm. Ensure insulator is correctly fitted in base under PCB to maintain safety creepage and clearance distances. Ensure base is firmly connected to supply earth via the earth stud marked . When using this enclosure, ensure that relevant safety standards (e.g., EN60950) are complied with, in respect to creepage and clearance distances, and distances through insulation. Europe (UK): 44 (1384) 842-211 Asia (HK): 852-2437-9662