BROADBAND DLVA MODEL STDLVA-90001 TECHNICAL FEATURE Features • Highest CW Immunity Available - -20 dBm max • Wideband performance • Large dynamic range Performance Operating Frequency ............................................2 - 18 GHz Tangential Signal Sensitivity (TSS) .......... .-67 dBm max Description Frequency Flatness ....................................+/- 2 dB max The STDLVA-90001 broadband DLVA represents the Operating Dynamic Range .......................-67 to +5 dBm latest design techniques and high performance Linearity ................................................. +/- 1.5 dB max configuration. The design is a dual detector amplified (Best fit straight line at each temperature and frequency) design with a unique video amplification and summing Slope..................................... 75 mV/dB nominal (adjustable) technique. The amplifier is fully temperature Rise Time ................................................. 35 ns typical compensated for superior performance. The device is Fall Time ................................................. 400 ns typical housed in a fully hermetically sealed enclosure for high reliability. Power Supply ..........................+15 VDC @ 200 mA typ, -15 VDC @ 15 mA typ (no RF output) RF Connector .............................................SMA Female DC Connector .......................................................... Pins Operating Temperature Range ............................0 to +70 C Package Size .......................................... 4.60”x2.90”x1.125” Best fit error room temp flatness room unit 3.00 3.00 2.00 2.00 1.00 1.00 0.00 -70 -60 -50 -40 -30 -20 -10 0 10 6.000 GHz 9.000 GHz 12.000 GHz 15.000 GHz 18.000 GHz averm -1.00 -2.00 -3.00 STC Microwave Systems – Olektron www.craneae.com 28 Tozer Road • phone: 978-524-7200 • Revision 90001-SDTLVA 20050531 Beverly, MA 01915 email: [email protected] 0.00 -80 -70 -60 -50 -40 -30 -20 -10 0 -1.00 -2.00 -3.00 10 6.000 GHz 9.000 GHz 12.000 GHz 15.000 GHz 18.000 GHz