ZL50211 256 Channel Voice Echo Canceller Data Sheet Features • • January 2006 ZL50211 has eight Echo Voice Processors in a single BGA package. This single device provides 256 channels of 64 msec echo cancellation or 128 channels at 128 msec echo cancellation Ordering Information ZL50211GBC 535 Ball BGA Trays ZL50211GBG2 535 Ball BGA** Trays **Pb Free Tin/Silver/Copper Each Echo Voice Processor has the capability of cancelling echo over 32 channels • Each Echo Voice Processor (EVP) shares the address bus and data bus with each other • Fully compliant to ITU-T G.165, G.168 (2000) and (2002) specifications • -40°C to +85°C • Each EVP can be programmed independently in any mode e.g., Back-to-Back or Extended Delay to provide capability of cancelling different echo tails Passed all AT&T voice quality tests for carrier grade echo canceller • Each EVP has 0 to -12 dB level adjusters at all signal ports (Rin, Sin, Sout and Rout) • The ZL50211 provides more than 58% board space savings when compared with the eight Echo Voice Processors packaged devices • Each EVP has the same JTAG identification code • Each EVP has a Patented Advanced Non-Linear Processor with high quality subjective performance Each EVP has protection against narrow band signal divergence and instability in high echo environments • Voice over IP network gateways • Voice over ATM, Frame Relay • T1/E1/J1 multichannel echo cancellation • Wireless base stations • Echo Canceller pools • DCME, satellite and multiplexer system ZL50211GB Rin1...Rin8 Rout1..Rout8 Sin1....Sin8 EVP1 EVP2 EVP3 D0....D7 Sout1..Sout8 EVP4 CS1..CS8 EVP5 IRQ1..IRQ8 A0..A12 DTA1..DTA8 Foi EVP8 C4i ODE EVP7 DS MLCK Fsel EVP6 RESET1..RESET8 R/W • Applications Figure 1 - ZL50211 Device Overview 1 Zarlink Semiconductor Inc. Zarlink, ZL and the Zarlink Semiconductor logo are trademarks of Zarlink Semiconductor Inc. Copyright 2003-2006, Zarlink Semiconductor Inc. All Rights Reserved. ZL50211 Data Sheet Description The ZL50211 Voice Echo Canceller implements a cost effective solution for telephony voice-band echo cancellation conforming to ITU-T G.168 requirements. The ZL50211 architecture contains 128 groups of two echo cancellers (ECA and ECB) which can be configured to provide two channels of 64 milliseconds or one channel of 128 milliseconds echo cancellation. This provides 256 channels of 64 milliseconds to 128 channels of 128 milliseconds echo cancellation or any combination of the two configurations. The ZL50211 supports ITU-T G.165 and G.164 tone disable requirements. VDD1 (3.3V) VDD2 (1.8V) VSS ODE Echo Canceller Pool Rin Sin Serial to Parallel MCLK Fsel PLL C4i F0i Timing Unit Group 0 Group 1 Group 2 Group 3 ECA/ECB ECA/ECB ECA/ECB ECA/ECB Group 4 Group 5 Group 6 Group 7 ECA/ECB ECA/ECB ECA/ECB ECA/ECB Group 8 Group 9 Group 10 Group 11 ECA/ECB ECA/ECB ECA/ECB ECA/ECB Group 12 Group 13 Group 14 Group 15 ECA/ECB ECA/ECB ECA/ECB ECA/ECB Parallel to Serial Note: Refer to Figure 4 for EVP block diagram Rout Sout IC0 RESET Microprocessor Interface DS CS R/W A12-A0 DTA Test Port D7-D0 IRQ TMS TDI TDO TCK TRST Figure 2 - Single Echo Voice Processor (EVP) Overview 2 Zarlink Semiconductor Inc. ZL50211 Data Sheet Features of Echo Voice Processor (EVP) • Each EVP can cancel echo tails of 64 ms (32 channels) to 128 ms (16 channels) with the ability to mix channels at 128 ms or 64 ms in any combination • Independent Power Down mode for each group of 2 channels for power management • Fully compliant to ITU-T G.165, G.168 (2000) and (2002) specifications • Passed all AT&T voice quality tests for carrier grade echo canceller • Compatible to ST-BUS and GCI interface at 2 Mb/s serial PCM • PCM coding, µ/A-Law ITU-T G.711 or sign magnitude • Per channel Fax/Modem G.164 2100 Hz or G.165 2100 Hz phase reversal Tone Disable • Per channel echo canceller parameters control • Transparent data transfer and mute • Fast reconvergence on echo path changes • Fully programmable convergence speeds • Patented Advanced Non-Linear Processor with high quality subjective performance • Protection against narrow band signal divergence and instability in high echo environments • 0 dB to -12 dB level adjusters (3 dB steps) at all signal ports • Offset nulling of all PCM channels • 10 MHz or 20 MHz master clock operation • 3.3 V pads and 1.8 V Logic core operation with 5-Volt tolerant inputs • IEEE-1149.1 (JTAG) Test Access Port 3 Zarlink Semiconductor Inc. ZL50211 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 Data Sheet 17 18 19 20 21 22 23 24 25 26 27 28 29 30 1 A A B B C C D D E E F F G G ZL50211GB H J H J BGA BALL GRID ARRAY K K L L M M N N P P R R T T U U V V W W Y Y AA AA AB AB AC AC AD AD AE AE AF AF AG AG AH AH AJ AJ AK AK 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 Figure 3 - 535 Ball BGA Ball Grid Array 4 Zarlink Semiconductor Inc. 24 25 26 27 28 29 30 ZL50211 Data Sheet Pin Description Signal Name Signal Type VDD1 = 3.3V (VDD_IO) Power VDD2 = 1.8V (VDD_Core) Power VSS Power BGA Ball # Signal Description AC5,AC26,AC27,AD26,AD5,AE5,AF12,AF13,AF1 4,AF17,AF18,AF19,AF24,AF6,AF7,AF8,AG24,AH 24,E13,E14,E17,E18,E19,E23,E24,E25,E6,E7,E8, F5,G26,G27,G5,H26,H5,M26,M5,N26,N5,P26,P27 , P4,P5,U26,U27,U4,U5,V26,V5,W26,W5 Positive Power Supply. Nominally 3.3 volt (I/O voltage). AA26,AA28,AA3,AA5,AB26,AB28,AB3,AB5,AF11, AF20,AG10,AG21,AG22,AH10,AH11,AH22,AJ15, AJ16,AJ9,AK9,C10,C11,C22,C23,C9,D10,D23,D9, E11,E20,E21,E22,J26,J27,J4,J5,K26,K27,K3,K5, L26,L27,L3,L5,Y26, Y27,Y3,Y5 Positive Power Supply. Nominally 1.8 volt (Core voltage). A29,A30,AF5,AG15,AG16,AG26,AG27,AG4,AH15 Ground , AH16,AH21,AH28,AH3,AJ2,AJ21,AJ29,AK1,AK30, B1,B15,B16,B2,B29,C15,C16,C28,C3,D15,D16, D27,D4,E26,E5,N13,N14,N15,N16,N17,N18,P13, P14,P15,P16,P17,P18,R13,R14,R15,R16,R17, R18,R2,R27,R28,R29,R3,R4,T13,T14,T15,T16, T17,T18,T2,T27,T28,T29,T3,T4,U13,U14,U15, U16,U17,U18,V13,V14,V15,V16, V17,V18 TEST PINS TE1, TE2, TE3, TE4, TE5, TE6, TE7, TE8 OUTPUT TEST PINS M4,AK26,M3,AJ4,AK4,AK25,K30,N28 Test Mode Pins Test pins Internal Connection. Connected to VSS for normal operation. D8,P28,C12,AK10,AH12,AD29,H28,J29,AC28, No connection. D12,P29,E9,AJ11,AK11,AD30,G28,H29,AB27,A3, These pins must be left open for normal P2,A2,Y1,AA1,AJ17,C20,B21,AK17,B3,P1,D3, operation. AA2,AB1,AK18,B22,D21,AJ18,C2,R1,E3,AB2, AB4,AH18,D19,A22,AK19,D2,T1,E4,AC1,AC2, AG18,A21,B20,AJ19,C1,U1,F4,AC4,AD1,AK20, C19,A20,AH19,F3,U2,E2,AC3,AD2,AK21,B19, A19,AG19,E10,P30,B12,AJ12,AG13,AC29,J30, G29,AC30,A11,N30,D11,AH13,AK12,AB29,H30, G30,AB30,A10,N27,B11,AJ13,AG14,AA27,F29, F30,AA29,A9,A14,B10,AG11,AG12,Y28,E29,E28, AA30,A8,A13,B9,AJ10,AF10,Y29,D29,E30,Y30, C8,B14,B8,AG9,AH9,W28,D26,D28,W29,C4, E12,C5,AA4,Y4,R30,A23,B23, T30,B4,P3,A4,Y2,W1,AG17,D20,C21,AH17 5 Zarlink Semiconductor Inc. ZL50211 Data Sheet Pin Description (continued) Signal Name INPUT TEST PINS Signal Type SC_EN, SC_FCLK, A27,D5,A25,A26,A24,B24,A28 SC_IN, SC_M_MCLK, SC_RESET, SC_SET, SC_T_MCLK, THalt and TStep Signal Name Halt Step Signal Type Signal Description BGA Ball # C14, D14 BGA Ball # Internal Connection. Connected to VSS for normal operation. Internal Connection. Connected to VSS for normal operation. Signal Description User Signal Pins D0, D1, D2, D3, D4, D5, D6, D7 User Signals AK7,AJ8,AK8, Data Bus D0 to D7 (Bidirectional). These pins form AJ27,AK29,AJ28, the 8-bit bidirectional data bus of the microprocessor port. They are connected to all the EVP’s. AH27, AJ30 A0,A1,A2,A3,A4,A5, A6,A7, A8, A9, A10,A11,A12 User Signals AG28,AH29, Address A0 to A12 (Input). These inputs provide the AH30,AG29,AF28, A12 - A0 address lines to the internal registers. They AG30,AE28,AF29, are connected to all the EVP’s. AE29,AF30,AD27, AE30,AD28 CS1,CS2,CS3, CS4, CS5, CS6, CS7, CS8 User Signals R5,L28,T5,AF15, Chip Select (Input). These active low inputs are used AF16,E16,T26, enable the microprocessor interface of each EVP. R26 EVP Reset (Schmitt Trigger Input). An active low resets the device and puts the Voice Processor into a M2,AH23,M1,AH5, low-power stand-by mode. When the RESET pin is AJ5,AJ23,N29,M30 returned to logic high and a clock is applied to the MCLK pin, the EVP will automatically execute initialization routines, which preset all the Control and Status Registers to their default power-up values. Each reset pin controls a single processor. A user can connect all of them together if required. RESET1 RESET2, RESET3, RESET4, RESET5, RESET6, RESET7, RESET8 User Signals Rin1,Rin2,Rin3, Rin4,Rin5,Rin6, Rin7,Rin8 User Signals C6,V27,B5,AG5, Receive PCM Signal Inputs (Input). Port 1 TDM data AH6,U28,B27,B28 input streams. Each Rin pin receives serial TDM data streams at 2.048 Mb/s with 32 channels per stream. Sin1,Sin2,Sin3,Sin4, Sin5,Sin6,Sin7,Sin8 User Signals C7,U30,B6,AG7, Send PCM Signal Inputs (Input). Port 2 TDM data AG6,U29,B30,C27 input streams. Each Sin pin receives serial TDM data streams at 2.048 Mb/s with 32 channels per stream. 6 Zarlink Semiconductor Inc. ZL50211 Signal Name Signal Type BGA Ball # Data Sheet Signal Description Rout1,Rout2,Rout3, Rout4,Rout5,Rout6, Rout7,Rout8, User Signals A5,V30,A6,AH7, Receive PCM Signal Outputs (Output). Port 2 TDM AG8,V28,C26,C30 data output streams. Each Rout pin outputs serial TDM data streams at 2.048 Mb/s with 32 channels per stream. Sout1,Sout2,Sout3, Sout4,Sout5,Sout6, Sout7,Sout8 User Signals B7,W27,A7,AH8, Send PCM Signal Outputs (Output). Port 1 TDM AF9,W30,C29,D30 data output streams. Each Sout pin outputs serial TDM data streams at 2.048 Mb/s with 32 channels per stream. User Signal K29 DS Data Strobe (Input). This active low input works in conjunction with CS to enable the read and write operations. This signal is connected to all processors. User Signal M29 R/W Read/Write (Input). This input controls the direction of the data bus lines (D7-D0) during a microprocessor access. This signal is connected to all processors. DTA1, DTA2, DTA3, DTA4, DTA5, DTA6, DTA7, DTA8 User Signals N2,AK28,N1,AK6, Data Transfer Acknowledgment (Open Drain AJ7,AK27,M28, Output). These active low outputs indicate that a data bus transfer is completed. A pull-up resistor (1 K M27 typical) is required at these outputs. User Signal V29 Output Drive Enable (Input). This input pin is logically AND’d with the ODE bit-6 of the Main Control Register. When both ODE bit and ODE input pin are high, the Rout and Sout ST-BUS outputs are enabled. When the ODE bit is low or the ODE input pin is low, the Rout and Sout ST-BUS outputs are high impedance. This signal is connected to all processors. User Signal B26 Frame Pulse (Input). This input accepts and automatically identifies frame synchronization signals formatted according to ST-BUS or GCI interface specifications.This signal is connected to all processors. User Signal B25 Serial Clock (Input). 4.096 MHz serial clock for shifting data in/out on the serial streams (Rin, Sin, Rout, Sout).This signal is connected to all processors. ODE F0i C4i User Signal A15 Frequency select (Input). This input selects the Master Clock frequency operation. When Fsel pin is low, nominal 20 MHz Master Clock input must be applied. When Fsel pin is high, nominal 10 MHz Master Clock input must be applied.This signal is connected to all processors. Fsel MCLK User Signal A16 Master Clock (Input). Nominal 10 MHz or 20 MHz Master Clock input. May be connected to an asynchronous (relative to frame signal) clock source.This signal is connected to all processors. 7 Zarlink Semiconductor Inc. ZL50211 Signal Name IRQ1, IRQ2, IRQ3, IRQ4, IRQ5, IRQ6, IRQ7, IRQ8 Signal Type User Signals Extra Device Pins BGA Ball # Data Sheet Signal Description N4,AJ26,N3,AK5, Interrupt Request (Open Drain Output). These AJ6,AG23,L30,L29 outputs go low when an interrupt occurs in any channel. Each IRQ returns high when all the interrupts have been read from the Interrupt FIFO Register of respective EVP. A pull-up resistor (1 K typical) is required at these outputs. W3,E15,V4,AK16, No connection. The ball pins must be left open for AK15,AK14,D13, normal operation. C13,V3,A12,B13, AK13,AH14,U3,V2, AJ14 JTAG SIGNAL PINS TMS K2 Test Mode Select (3.3 V Input). JTAG signal that controls the state transitions of the TAP controller. This pin is pulled high by an internal pull-up when not driven. This signal is connected to all processors. D6 Test Clock (3.3 V Input). Provides the clock to the JTAG test logic.This signal is connected to all processors. D7 Test Reset (3.3 V Input). Asynchronously initializes the JTAG TAP controller by putting it in the Test-LogicReset state. This pin should be pulsed low on powerup or held low, to ensure that all the EVP’s are in the normal functional mode. This pin is pulled by an internal pull-down when not driven. This signal is connected to all EVP’s. JTAG Signal TCK JTAG Signal TRST JTAG Signal TDI1,TDI2,TDI3,TDI4, TDI5,TDI6,TDI7,TDI8 JTAG Signals K1,AK23,L2,AK2, Test Serial Data In (3.3 V Input). JTAG serial test AJ3,AH20,F27,H27 instructions and data are shifted in on these pins. These pins are pulled high by an internal pull-up when not driven. TDO1,TDO2,TDO3, TDO4,TDO5,TDO6 TDO7,TDO8 JTAG Signals L1,AJ22,L4,AH4, Test Serial Data Out (Output). JTAG serial data is AK3,AK24,J28,K28 outputted on these pins on the falling edge of TCK. These pins are held in high impedance state when JTAG scan is not enabled. PLL SIGNAL PINS PLLVDD2 = 1.8V PLL Power PLLVSS1 PLLVSS2 PLL Power H3,V1,H4,AE3, AG2,AE26,D22, C24, AE27 PLL Power Supply. Must be connected to PLLVDD2 = 1.8V. J3,W2,H2,AF4, PLL Ground. Must be connected to VSS. AF3,AF27,D24, C25,AF26,H1,W4, J2, AH1,AG3,AF22, D25,E27,AF21 8 Zarlink Semiconductor Inc. ZL50211 Signal Name Signal Type BGA Ball # Data Sheet Signal Description T1M1, T1M2, T1M3, T1M4, T1M5, T1M6, T1M7, T1M8 PLL Test Signals T2M1, T2M2, T2M3, T2M4, T2M5, T2M6, T2M7, T2M8 PLL Test F2,AG25,G3,AF1, Internal Connection. Connected to VSS for normal Signals AD3,AF25,B18,A18 operation. D1,AH26,E1,AE1, Internal Connection. Connected to VSS for normal AD4,AK22,D18, operation. C18 SG1, SG2, SG3, SG4, SG5, SG6, SG7, SG8 PLL Test Signals G4,AJ25,F1,AE2, Internal Connection. Connected to VSS for normal AG1, operation. AH25,B17,C17 DT1, DT2, DT3, DT4, DT5, DT6, DT7, DT8 PLL Test Signals G2,AF23,G1,AF2, No connection. These pins must be left open for AE4,AJ24,D17, normal operation. A17 AT1, AT2, AT3, AT4, AT5, AT6, AT7, AT8 PLL Test Signals K4,AJ20,J1, AH2,AJ1,AG20, F28,F26 No connection. These pins must be left open for normal operation. The following description applies to a single EVP (Echo Voice Processor). Note that the ZL50211 contains eight EVP’s. 1.0 Single Echo Voice Processor (EVP) Description Each single Echo Voice Processor (EVP) contains 32 echo cancellers divided into 16 groups. Each group has two echo cancellers, Echo Canceller A (ECA) and Echo Canceller B (ECB). Each group can be configured in Normal, Extended Delay or Back-to-Back configurations. In Normal configuration, a group of echo cancellers provides two channels of 64 ms echo cancellation, which run independently on different channels. In Extended Delay configuration, a group of echo cancellers achieves 128 ms of echo cancellation by cascading the two echo cancellers (A & B). In Back-to-Back configuration, the two echo cancellers from the same group are positioned to cancel echo coming from both directions in a single channel, providing full-duplex 64 ms echo cancellation. Each Echo Voice Processor contains the following main elements (see Figure 4). • Adaptive Filter for estimating the echo channel • Subtractor for cancelling the echo • Double-Talk detector for disabling the filter adaptation during periods of double-talk • Path Change detector for fast reconvergence on major echo path changes • Instability Detector to combat instability in very low ERL environments • Patented Advanced Non-Linear Processor for suppression of residual echo, with comfort noise injection • Disable Tone Detectors for detecting valid disable tones at send and receive path inputs • Narrow-Band Detector for preventing Adaptive Filter divergence from narrow-band signals • Offset Null filters for removing the DC component in PCM channels • 0 to -12 dB level adjusters at all signal ports • Parallel controller interface compatible with Motorola microcontrollers • PCM encoder/decoder compatible with µ/A-Law ITU-T G.711 or Sign-Magnitude coding 9 Zarlink Semiconductor Inc. ZL50211 Each echo canceller in the EVP has four functional states: Mute, Bypass, Disable Adaptation and Enable Adaptation. These are explained in the section entitled Echo Canceller Functional States. Sin (channel N) 0 to -12dB Level Adjust µ/A-Law/ Linear Offset Null ST-BUS PORT2 Adaptive Filter Disable Tone Detector Σ Instability Detector Microprocessor Interface Double - Talk Detector Narrow-Band Detector Rout (channel N) Linear/ µ/A-Law 0 to -12dB Level Adjust Non-Linear Processor Control • Data Sheet MuteR 0 to -12dB Level Adjust 0 to -12dB Level Adjust Offset Null Linear/ µ/A-Law Sout (channel N) MuteS Path Change Detector ST-BUS PORT1 Disable Tone Detector µ/A-Law/ Linear Rin (channel N) Echo Canceller (N), where 0 < N < 31 Programmable Bypass Figure 4 - Functional Block Diagram of an Echo Canceller 1.1 Adaptive Filter The adaptive filter adapts to the echo path and generates an estimate of the echo signal. This echo estimate is then subtracted from Sin. For each group of echo cancellers, the Adaptive Filter is a 1024 tap FIR adaptive filter which is divided into two sections. Each section contains 512 taps providing 64 ms of echo estimation. In Normal configuration, the first section is dedicated to channel A and the second section to channel B. In Extended Delay configuration, both sections are cascaded to provide 128 ms of echo estimation in channel A. In Back-to-Back configuration, the first section is used in the receive direction and the second section is used in the transmit direction for the same channel. 1.2 Double-Talk Detector Double-Talk is defined as those periods of time when signal energy is present in both directions simultaneously. When this happens, it is necessary to disable the filter adaptation to prevent divergence of the Adaptive Filter coefficients. Note that when double-talk is detected, the adaptation process is halted but the echo canceller continues to cancel echo using the previous converged echo profile. A double-talk condition exists whenever the relative signal levels of Rin (Lrin) and Sin (Lsin) meet the following condition: Lsin > Lrin + 20log10(DTDT) where DTDT is the Double-Talk Detection Threshold. Lsin and Lrin are signal levels expressed in dBm0. A different method is used when it is uncertain whether Sin consists of a low level double-talk signal or an echo return. During these periods, the adaptation process is slowed down but it is not halted. The slow convergence speed is set using the Slow sub-register in Control Register 4. During slow convergence, the adaptation speed is reduced by a factor of 2Slow relative to normal convergence for non-zero values of Slow. If Slow equals zero, adaptation is halted completely. 10 Zarlink Semiconductor Inc. ZL50211 Data Sheet In the G.168 standard, the echo return loss is expected to be at least 6 dB. This implies that the Double-Talk Detector Threshold (DTDT) should be set to 0.5 (-6 dB). However, in order to achieve additional guardband, the DTDT is set internally to 0.5625 (-5 dB). In some applications the return loss can be higher or lower than 6 dB. The EVP allows the user to change the detection threshold to suit each application’s need. This threshold can be set by writing the desired threshold value into the DTDT register. The DTDT register is 16 bits wide. The register value in hexadecimal can be calculated with the following equation: DTDT(hex) = hex(DTDT(dec) * 32768) where 0 < DTDT(dec) < 1 Example:For DTDT = 0.5625 (-5 dB), the hexadecimal value becomes hex(0.5625 * 32768) = 4800hex 1.3 Path Change Detector Integrated into the EVP is a Path Change Detector. This permits fast reconvergence when a major change occurs in the echo channel. Subtle changes in the echo channel are also tracked automatically once convergence is achieved, but at a much slower speed. The Path Change Detector is activated by setting the PathDet bit in Control Register 3 to “1”. An optional path clearing feature can be enabled by setting the PathClr bit in Control Register 3 to “1”. With path clearing turned on, the existing echo channel estimate will also be cleared (i.e., the adaptive filter will be filled with zeroes) upon detection of a major path change. 1.4 Non-Linear Processor (NLP) After echo cancellation, there is always a small amount of residual echo which may still be audible. The EVP uses Zarlink’s patented Advanced NLP to remove residual echo signals which have a level lower than the Adaptive Suppression Threshold (TSUP in G.168). This threshold depends upon the level of the Rin (Lrin) reference signal as well as the programmed value of the Non-Linear Processor Threshold register (NLPTHR). TSUP can be calculated by the following equation: TSUP = Lrin + 20log10(NLPTHR) where NLPTHR is the Non-Linear Processor Threshold register value and Lrin is the relative power level expressed in dBm0. The NLPTHR register is 16 bits wide. The register value in hexadecimal can be calculated with the following equation: NLPTHR(hex) = hex(NLPTHR(dec) * 32768) where 0 < NLPTHR(dec) < 1 When the level of residual error signal falls below TSUP, the NLP is activated further attenuating the residual signal by an additional 30 dB. To prevent a perceived decrease in background noise due to the activation of the NLP, a spectrally-shaped comfort noise, equivalent in power level to the background noise, is injected. This keeps the perceived noise level constant. Consequently, the user does not hear the activation and de-activation of the NLP. The NLP processor can be disabled by setting the NLPDis bit to “1” in Control Register 2. The comfort noise injector can be disabled by setting the INJDis bit to “1” in Control Register 1. It should be noted that the NLPTHR is valid and the comfort noise injection is active only when the NLP is enabled. 11 Zarlink Semiconductor Inc. ZL50211 Data Sheet The patented Advanced NLP provides a number of new and improved features over the original NLP found in previous generation devices. The differences between the Advanced NLP and the original NLP are summarized in Table 1. Feature Register or Bit(s) Advanced NLP Default Value Original NLP Default Value NLP Selection NLPSel (Control Register 3) 1 0 (feature not supported) Reject uncancelled echo as noise NLRun1 (Control Register 3) 1 0 (feature not supported) Reject double-talk as noise NLRun2 (Control Register 3) 1 0 (feature not supported) Noise level estimator ramping scheme InjCtrl (Control Register 3) 1 0 (feature not supported) Noise level ramping rate NLInc (Noise Control) 5(hex) C(hex) Noise level scaling Noise Scaling 16(hex) 74(hex) Table 1 - Comparison of NLP Types The NLPSel bit in Control Register 3 selects which NLP is used. A “1” will select the Advanced NLP, “0” selects the original NLP. The Advanced NLP uses a new noise ramping scheme to quickly and more accurately estimate the background noise level. The noise ramping method of the original NLP can also be used. The InjCtrl bit in Control Register 3 selects the ramping scheme. The NLInc sub-register in Noise Control is used to set the ramping speed. When InjCtrl = 1 (such as with the Advanced NLP), a lower value will give faster ramping. When InjCtrl = 0 (such as with the original NLP), a higher value will give faster ramping. NLInc is a 4-bit value, so only values from 0 to F(hex) are valid. The Noise Scaling register can be used to adjust the relative volume of the comfort noise. Lowering this value will scale the injected noise level down, conversely, raising the value will scale the comfort noise up. Due to differences in the noise estimator operation, the Advanced NLP requires a different scaling value than the original NLP. Important Note: NLInc and the Noise Scaling register have been pre-programmed with G.168 compliant values. Changing these values may result in undesirable comfort noise performance! The Advanced NLP also contains safeguards to prevent double-talk and uncancelled echo from being mistaken for background noise. These features were not present in the original NLP. They can be disabled by setting the NLRun1 and NLRun2 bits in Control Register 3 to “0”. 1.5 Disable Tone Detector The G.165 recommendation defines the disable tone as having the following characteristics: 2100 Hz (±21 Hz) sine wave, a power level between -6 to -31 dBm0, and a phase reversal of 180 degrees (± 25 degrees) every 450 ms (±25 ms). If the disable tone is present for a minimum of one second with at least one phase reversal, the Tone Detector will trigger. The G.164 recommendation defines the disable tone as a 2100 Hz (+21 Hz) sine wave with a power level between 0 to -31 dBm0. If the disable tone is present for a minimum of 400 ms, with or without phase reversal, the Tone Detector will trigger. 12 Zarlink Semiconductor Inc. ZL50211 Data Sheet Each EVP has two Tone Detectors per channels (for a total of 64) in order to monitor the occurrence of a valid disable tone on both Rin and Sin. Upon detection of a disable tone, TD bit of the Status Register will indicate logic high and an interrupt is generated (i.e., IRQ pin low). Refer to Figure 5 and to the Interrupts section. Rin Tone Detector Sin Tone Detector ECA Status reg TD bit Echo Canceller A Rin Tone Detector Sin Tone Detector ECB Status reg TD bit Echo Canceller B Figure 5 - Disable Tone Detection Once a Tone Detector has been triggered, there is no longer a need for a valid disable tone (G.164 or G.165) to maintain Tone Detector status (i.e., TD bit high). The Tone Detector status will only release (i.e. TD bit low) if the signals Rin and Sin fall below -30 dBm0, in the frequency range of 390 Hz to 700 Hz, and below -34 dBm0, in the frequency range of 700 Hz to 3400 Hz, for at least 400 ms. Whenever a Tone Detector releases, an interrupt is generated (i.e., IRQ pin low). The selection between G.165 and G.164 tone disable is controlled by the PHDis bit in Control Register 2 on a per channel basis. When the PHDis bit is set to “1”, G.164 tone disable requirements are selected. In response to a valid disable tone, the echo canceller must be switched from the Enable Adaptation state to the Bypass state. This can be done in two ways, automatically or externally. In automatic mode, the Tone Detectors internally control the switching between Enable Adaptation and Bypass states. The automatic mode is activated by setting the AutoTD bit in Control Register 2 to high. In external mode, an external controller is needed to service the interrupts and poll the TD bits in the Status Registers. Following the detection of a disable tone (TD bit high) on a given channel, the external controller must switch the echo canceller from Enable Adaptation to Bypass state. 1.6 Instability Detector In systems with very low echo channel return loss (ERL), there may be enough feedback in the loop to cause stability problems in the Adaptive Filter. This instability can result in variable pitched ringing or oscillation. Should this ringing occur, the Instability Detector will activate and suppress the oscillations. The Instability Detector is activated by setting the RingClr bit in Control Register 3 to “1”. 1.7 Narrow Band Signal Detector (NBSD) Single or dual frequency tones (i.e. DTMF tones) present in the receive input (Rin) of the echo canceller for a prolonged period of time may cause the Adaptive Filter to diverge. The Narrow Band Signal Detector (NBSD) is designed to prevent this by detecting single or dual tones of arbitrary frequency, phase, and amplitude. When narrow band signals are detected, adaptation is halted but the echo canceller continues to cancel echo. The NBSD will be active regardless of the EVP functional state. However the NBSD can be disabled by setting the NBDis bit to “1” in Control Register 2. 13 Zarlink Semiconductor Inc. ZL50211 1.8 Data Sheet Offset Null Filter Adaptive filters in general do not operate properly when a DC offset is present at any input. To remove the DC component, each EVP incorporates Offset Null filters in both Rin and Sin inputs. The offset null filters can be disabled by setting the HPFDis bit to “1” in Control Register 2. 1.9 Adjustable Level Pads Each EVP provides adjustable level pads at Rin, Rout, Sin and Sout. This setup allows signal strength to be adjusted both inside and outside the echo path. Each signal level may be independently scaled with anywhere from 0 to -12 dB level, in 3 dB steps. Level values are set using the Gains register. CAUTION: Gain adjustment can help interface the ZL50211 to a particular system in order to provide optimum echo cancellation, but it can also degrade performance if not done carefully. Excessive loss may cause low signal levels and slow convergence. Exercise great care when adjusting these values. The -12 dB PAD bit in Control Register 1 is still supported as a legacy feature. Setting this bit will provide 12 dB of attenuation at Rin, and override the values in the Gains register. 1.10 ITU-T G.168 Compliance The ZL50211 has been certified G.168 (1997), (2000) and (2002) compliant in all 64 ms cancellation modes (i.e. Normal and Back-to-Back configurations) by in-house testing with the DSPG ECT-1 echo canceller tester. The ZL50211 has also been tested for G.168 compliance and all voice quality tests at AT&T Labs. The ZL50211 was classified as “carrier grade” echo canceller. 2.0 EVP Configuration The EVP architecture contains 32 echo cancellers divided into 16 groups. Each group has two echo cancellers which can be individually controlled (Echo Canceller A (ECA) and Echo Canceller B (ECB). They can be set in three distinct configurations: Normal, Back-to-Back, and Extended Delay. See Figures 6, 7, and 8. 2.1 Normal Configuration In Normal configuration, the two echo cancellers (Echo Canceller A and B) are positioned in parallel, as shown in Figure 6, providing 64 milliseconds of echo cancellation in two channels simultaneously. 14 Zarlink Semiconductor Inc. ZL50211 Sin channel A Data Sheet Sout + - echo path A Rout Adaptive Filter (64ms) channel A Rin PORT2 PORT1 ECA channel B + - echo path B Adaptive Filter (64ms) channel B ECB Figure 6 - Normal Device Configuration (64 ms) 2.2 Back-to-Back Configuration In Back-to-Back configuration, the two echo cancellers from the same group are positioned to cancel echo coming from both directions in a single channel providing full-duplex 64ms echo cancellation. See Figure 7. This configuration uses only one timeslot on PORT1 and PORT2 and the second timeslot normally associated with ECB contains zero code. Back-to-Back configuration allows a no-glue interface for applications where bidirectional echo cancellation is required. Sout + Sin echo path Adaptive Filter (64ms) Adaptive Filter (64ms) echo path Rout PORT2 ECA + Rin ECB PORT1 Figure 7 - Back-to-Back Device Configuration (64 ms) Back-to-Back configuration is selected by writing a “1” into the BBM bit of Control Register 1 for both Echo Canceller A and Echo Canceller B for a given group of echo canceller. Table 4 shows the 16 groups of 2 cancellers that can be configured into Back-to-Back. Examples of Back-to-Back configuration include positioning one group of echo cancellers between a codec and a transmission device or between two codecs for echo control on analog trunks. 15 Zarlink Semiconductor Inc. ZL50211 2.3 Data Sheet Extended Delay Configuration In this configuration, the two echo cancellers from the same group are internally cascaded into one 128 milliseconds echo canceller. See Figure 8. This configuration uses only one timeslot on PORT1 and PORT2 and the second timeslot normally associated with ECB contains quiet code. Sin channel A + Sout echo path A Rout PORT2 Adaptive Filter (128 ms) channel A Rin PORT1 ECA Figure 8 - Extended Delay Configuration (128 ms) Extended Delay configuration is selected by writing a “1” into the ExtDl bit in Echo Canceller A, Control Register 1. For a given group, only Echo Canceller A, Control Register 1, has the ExtDl bit. For Echo Canceller B Control Register 1, Bit 0 must always be set to zero. Table 4 shows the 16 groups of 2 cancellers that can each be configured into 64 ms or 128 ms echo tail capacity. 3.0 Echo Canceller Functional States Each echo canceller has four functional states: Mute, Bypass, Disable Adaptation and Enable Adaptation. 3.1 Mute In Normal and in Extended Delay configurations, writing a “1” into the MuteR bit replaces Rin with quiet code which is applied to both the Adaptive Filter and Rout. Writing a “1” into the MuteS bit replaces the Sout PCM data with quiet code. +Zero (quiet code) LINEAR 16 bits 2’s complement SIGN/ MAGNITUDE µ-Law A-Law 0000hex 80hex CCITT (G.711) µ-Law A-Law FFhex D5hex Table 2 - Quiet PCM Code Assignment In Back-to-Back configuration, writing a “1” into the MuteR bit of Echo Canceller A, Control Register 2, causes quiet code to be transmitted on Rout. Writing a “1” into the MuteS bit of Echo Canceller A, Control Register 2, causes quiet code to be transmitted on Sout. In Extended Delay and in Back-to-Back configurations, MuteR and MuteS bits of Echo Canceller B must always be “0”. Refer to Figure 4 and to Control Register 2 for bit description. 16 Zarlink Semiconductor Inc. ZL50211 3.2 Data Sheet Bypass The Bypass state directly transfers PCM codes from Rin to Rout and from Sin to Sout. When Bypass state is selected, the Adaptive Filter coefficients are reset to zero. Bypass state must be selected for at least one frame (125 µs) in order to properly clear the filter. 3.3 Disable Adaptation When the Disable Adaptation state is selected, the Adaptive Filter coefficients are frozen at their current value. The adaptation process is halted, however, the echo canceller continues to cancel echo. 3.4 Enable Adaptation In Enable Adaptation state, the Adaptive Filter coefficients are continually updated. This allows the echo canceller to model the echo return path characteristics in order to cancel echo. This is the normal operating state. The echo canceller functions are selected in Control Register 1 and Control Register 2 through four control bits: MuteS, MuteR, Bypass and AdaptDis. Refer to the EVP Registers Description for details. 4.0 Echo Voice Processor (EVP) Throughput Delay The throughput delay of the EVP varies according to the device configuration. For all device configurations, Rin to Rout has a delay of two frames and Sin to Sout has a delay of three frames. In Bypass state, the Rin to Rout and Sin to Sout paths have a delay of two frames. 5.0 Serial PCM I/O Channels There are four TDM I/O streams, each with channels numbered from 0 to 31. One input stream is for Receive (Rin) channels, and the other input stream is for Send (Sin) channels. Likewise, two output streams is for Rout PCM channels, and Sout PCM channels. See Figure 9 for channel allocation. 5.1 Serial Data Interface Timing The ZL50211 provides ST-BUS and GCI interface timing. The Serial Interface clock frequency, C4i, is 4.096 MHz. The input and output data rate of the ST-BUS and GCI bus is 2.048 Mb/s. The 8 KHz input frame pulse can be in either ST-BUS or GCI format. The EVP automatically detects the presence of an input frame pulse and identifies it as either ST-BUS or GCI. In ST-BUS format, every second falling edge of the C4i clock marks a bit boundary, and the data is clocked in on the rising edge of C4i, three quarters of the way into the bit cell (See Figure 11). In GCI format, every second rising edge of the C4i clock marks the bit boundary, and data is clocked in on the second falling edge of C4i, half the way into the bit cell (see Figure 12). 125 µsec F0i ST-BUS F0i GCI interface Rin/Sin Rout/Sout Channel 0 Channel 1 Channel 30 Channel 31 Note: Refer to Figure 11 and Figure 12 for timing details. Figure 9 - ST-BUS and GCI Interface Channel Assignment for 2 Mb/s Data Streams 17 Zarlink Semiconductor Inc. ZL50211 Base Address + MS Byte LS Byte - 00hex - Data Sheet Base Address + Echo Canceller A Echo Canceller B MS Byte LS Byte Control Reg 1 - 20hex Control Reg 1 01hex Control Reg 2 - 21hex Control Reg 2 - 02hex Status Reg - 22hex Status Reg - 03hex Reserved - 23hex Reserved - 04hex Flat Delay Reg - 24hex Flat Delay Reg - 05hex Reserved - 25hex Reserved - 06hex Decay Step Size Reg - 26hex Decay Step Size Reg - 07hex Decay Step Number - 27hex Decay Step Number - 08hex Control Reg 3 - 28hex Control Reg 3 - 09hex Control Reg 4 - 29hex Control Reg 4 - 0Ahex Noise Scaling - 2Ahex Noise Scaling - 0Bhex Noise Control - 2Bhex Noise Control 0Dhex 0Chex Rin Peak Detect Reg 2Dhex 2Chex Rin Peak Detect Reg 0Fhex 0Ehex Sin Peak Detect Reg 2Fhex 2Ehex Sin Peak Detect Reg 11hex 10hex Error Peak Detect Reg 31hex 30hex Error Peak Detect Reg 13hex 12hex Reserved 33hex 32hex Reserved 15hex 14hex DTDT Reg 35hex 34hex DTDT Reg 17hex 16hex Reserved 37hex 36hex Reserved 19hex 18hex NLPTHR 39hex 38hex NLPTHR 1Bhex 1Ahex Step Size, MU 3Bhex 3Ahex Step Size, MU 1Dhex 1Chex Gains 3Dhex 3Chex Gains 1Fhex 1Ehex Reserved 3Fhex 3Ehex Reserved Table 3 - Memory Mapping of Per Channel Control and Status Registers 6.0 Memory Mapped Control and Status Registers Internal memory and registers are memory mapped into the address space of the HOST interface. The internal dual ported memory is mapped into segments on a “per channel” basis to monitor and control each individual echo canceller and associated PCM channels. For example, in Normal configuration, echo canceller #5 makes use of Echo Canceller B from group 2. It occupies the internal address space from 0A0hex to 0BFhex and interfaces to PCM channel #5 on all serial PCM I/O streams. As illustrated in Table 3, the “per channel” registers provide independent control and status bits for each echo canceller. Figure 10 shows the memory map of the control/status register blocks for all echo cancellers of the EVP. When Extended Delay or Back-to-Back configuration is selected, Control Register 1 of ECA and ECB and Control Register 2 of the selected group of echo cancellers require special care. Refer to the EVP Register description section. 18 Zarlink Semiconductor Inc. ZL50211 Data Sheet Table 4 is a list of the channels used for the 16 groups of echo cancellers when they are configured as Extended Delay or Back-to-Back. 7.0 Normal Configuration For a given group (group 0 to 15), 2 PCM I/O channels are used. For example, group 1 Echo Cancellers A and B, channels 2 and 3 are active. Group Channels Group Channels 0 0, 1 8 16, 17 1 2, 3 9 18, 19 2 4, 5 10 20, 21 3 6, 7 11 22, 23 4 8, 9 12 24, 25 5 10, 11 13 26, 27 6 12, 13 14 28, 29 7 14, 15 15 30, 31 Table 4 - Group and Channel Allocation 7.1 Extended Delay Configuration For a given group (group 0 to 15), only one PCM I/O channel is active (Echo Canceller A) and the other channel carries quiet code. For example, group 2, Echo Canceller A (Channel 4) will be active and Echo Canceller B (Channel 5) will carry quiet code. 7.2 Back-to-Back Configuration For a given group (group 0 to 15), only one PCM I/O channel is active (Echo Canceller A) and the other channel carries quiet code. For example, group 5, Echo Canceller A (Channel 10) will be active and Echo Canceller B (Channel 11) will carry quiet code. 19 Zarlink Semiconductor Inc. ZL50211 Data Sheet Group 0 Echo Cancellers Registers Channel 0, ECA Ctrl/Stat Registers 0000h --> 001Fh Channel 1, ECB Ctrl/Stat Registers 0020h --> 003Fh Group 1 Echo Cancellers Registers Channel 2, ECA Ctrl/Stat Registers 0040h --> 005Fh Channel 3, ECB Ctrl/Stat Registers 0060h --> 007Fh Groups 2 --> 14 Echo Cancellers Registers Group 15 Echo Cancellers Registers Channel 30, ECA Ctrl/Stat Registers 03C0h --> 03DFh Channel 31, ECB Ctrl/Stat Registers 03E0h --> 03FFh Main Control Registers <15:0> 0400h --> 040Fh Interrupt FIFO Register 0410h Test Register 0411h Reserved Test Register 0412h ---> FFFFh Figure 10 - Memory Mapping 7.3 Power Up Sequence On power up, the RESET pin must be held low for 100 µs. Forcing the RESET pin low will put each EVP in power down state. In this state, all internal clocks are halted, D<7:0>, Sout, Rout, DTA and IRQ pins are tristated. The 16 Main Control Registers, the Interrupt FIFO Register and the Test Register are reset to zero. When the RESET pin returns to logic high and a valid MCLK is applied, the user must wait 500 µs for the PLL to lock. C4i and F0i can be active during this period. Once the PLL has locked, the user must power up the 16 groups of echo cancellers individually, by writing a “1” into the PWUP bit in each group of echo canceller’s Main Control Register. For each group of echo cancellers, when the PWUP bit toggles from zero to one, echo cancellers A and B execute their initialization routine. The initialization routine sets their registers, Base Address+00hex to Base Address+3Fhex, to the default power-up value and clears the Adaptive Filter coefficients. Two frames are necessary for the initialization routine to execute properly. Once the initialization routine is executed, the user can set the per channel Control Registers, Base Address+00hex to Base Address+3Fhex, for the specific application. 7.4 Power Management Each group of echo cancellers can be placed in Power Down mode by writing a “0” into the PWUP bit in their respective Main Control Register. When a given group is in Power Down mode, the corresponding PCM data are bypassed from Rin to Rout and from Sin to Sout with two frames delay. Refer to the Main Control Register section for description. The typical power consumption can be calculated with the following equation: where 0 ≤ Nb_of_groups ≤ 16. PC = 9 * Nb_of_groups + 3.6, in mW 20 Zarlink Semiconductor Inc. ZL50211 7.5 Data Sheet Call Initialization To ensure fast initial convergence on a new call, it is important to clear the Adaptive Filter. This is done by putting the echo canceller in bypass mode for at least one frame (125 µs) and then enabling adaptation. Since the Narrow Band Detector is “ON” regardless of the functional state of the Echo Canceller it is recommended that the Echo Cancellers are reset before any call progress tones are applied. 7.6 Interrupts The EVP provides an interrupt pin (IRQ) to indicate to the HOST processor when a G.164 or G.165 Tone Disable is detected and released. Although each EVP may be configured to react automatically to tone disable status on any input PCM voice channels, the user may want for the external HOST processor to respond to Tone Disable information in an appropriate application-specific manner. Each echo canceller will generate an interrupt when a Tone Disable occurs and will generate another interrupt when a Tone Disable releases. Upon receiving an IRQ, the HOST CPU should read the Interrupt FIFO Register. This register is a FIFO memory containing the channel number of the echo canceller that has generated the interrupt. All pending interrupts from any of the echo cancellers and their associated input channel number are stored in this FIFO memory. The IRQ always returns high after a read access to the Interrupt FIFO Register. The IRQ pin will toggle low for each pending interrupt. After the HOST CPU has received the channel number of the interrupt source, the corresponding per channel Status Register can be read from internal memory to determine the cause of the interrupt (see Table 3 for address mapping of Status register). The TD bit indicates the presence of a Tone Disable. The MIRQ bit 5 in the Main Control Register 0 masks interrupts from the EVP. To provide more flexibility, the MTDBI (bit-4) and MTDAI (bit-3) bits in the Main Control Register<15:0> allow Tone Disable to be masked or unmasked from generating an interrupt on a per channel basis. Refer to the Registers Description section. 8.0 JTAG Support The EVP JTAG interface conforms to the Boundary-Scan standard IEEE1149.1. This standard specifies a designfor-testability technique called Boundary-Scan test (BST). The operation of the Boundary Scan circuitry is controlled by an Test Access Port (TAP) controller. JTAG inputs are 3.3 Volts compliant only. 8.1 Test Access Port (TAP) The TAP provides access to many test functions of the EVP. It consists of four input pins and one output pin. The following pins are found on the TAP. • • • Test Clock Input (TCK) The TCK provides the clock for the test logic. The TCK does not interfere with any on-chip clock and thus remains independent. The TCK permits shifting of test data into or out of the Boundary-Scan register cells concurrent with the operation of the device and without interfering with the on-chip logic. Test Mode Select Input (TMS) The logic signals received at the TMS input are interpreted by the TAP Controller to control the test operations. The TMS signals are sampled at the rising edge of the TCK pulse. This pin is internally pulled to VDD1 when it is not driven from an external source. Test Data Input (TDI) Serial input data applied to this port is fed either into the instruction register or into a test data register, depending on the sequence previously applied to the TMS input. Both registers are described in a 21 Zarlink Semiconductor Inc. ZL50211 • • 8.2 Data Sheet subsequent section. The received input data is sampled at the rising edge of TCK pulses. This pin is internally pulled to VDD1 when it is not driven from an external source. Test Data Output (TDO) Depending on the sequence previously applied to the TMS input, the contents of either the instruction register or data register are serially shifted out towards the TDO. The data from the TDO is clocked on the falling edge of the TCK pulses. When no data is shifted through the Boundary Scan cells, the TDO driver is set to a high impedance state. Test Reset (TRST) This pin is used to reset the JTAG scan structure. This pin is internally pulled to VSS. Instruction Register In accordance with the IEEE 1149.1 standard, the EVP uses public instructions. The JTAG Interface contains a 3-bit instruction register. Instructions are serially loaded into the instruction register from the TDI when the TAP Controller is in its shifted-IR state. Subsequently, the instructions are decoded to achieve two basic functions: to select the test data register that will operate while the instruction is current, and to define the serial test data register path, which is used to shift data between TDI and TDO during data register scanning. 8.3 Test Data Registers As specified in IEEE 1149.1, each of the Echo Voice Processor’s JTAG Interface contains three test data registers: • • • Boundary-Scan register The Boundary-Scan register consists of a series of Boundary-Scan cells arranged to form a scan path around the boundary of each EVP core logic. Bypass Register The Bypass register is a single stage shift register that provides a one-bit path from TDI to TDO. Device Identification register The Device Identification register provides access to the following encoded information: device version number, part number and manufacturer's name. 22 Zarlink Semiconductor Inc. ZL50211 Data Sheet Absolute Maximum Ratings* Parameter Symbol Min. Max. Units 1 I/O Supply Voltage (VDD1) VDD_IO -0.5 5.0 V 2 Core Supply Voltage (VDD2) VDD_CORE -0.5 2.5 V 3 Input Voltage VI3 VSS - 0.5 VDD1+0.5 V 4 Input Voltage on any 5 V Tolerant I/O pins VI5 VSS - 0.3 7.0 V 5 Continuous Current at digital outputs Io 20 mA 6 Package power dissipation PD 3.0 W 150 °C 7 Storage temperature TS -55 * Exceeding these values may cause permanent damage. Functional operation under these conditions is not implied. . Recommended Operating Conditions - Voltages are with respect to ground (Vss) unless otherwise stated Characteristics Sym. Min. Typ.‡ Max. Units +85 °C 1 Operating Temperature TOP -40 2 I/O Supply Voltage (VDD_IO) VDD1 3.0 3.3 3.6 V 3 Core Supply Voltage (VDD_CORE) VDD2 1.6 1.8 2.0 V 4 Input High Voltage on 3.3 V tolerant I/O VIH3 0.7VDD1 VDD1 V 5 Input High Voltage on 5 V tolerant I/O pins VIH5 0.7VDD1 5.5 V 6 Input Low Voltage VIL 0.3VDD1 V ‡ Typical figures are at 25°C and are for design aid only: not guaranteed and not subject to production testing DC Electrical Characteristics† - Voltages are with respect to ground (Vss) unless otherwise stated. Characteristics Static Supply Current 1 IDD_IO (VDD1 = 3.3 V) Single EV Processor 3 4 I N P U T S 10 Test Conditions 250 µA RESET = 0 IDD_CORE 65 mA 32 channels of single EVP are active Power Consumption PC 1.2 W All EVP’s i.e.,256 channels are active Input High Voltage VIH Input Low Voltage VIL Input Pin Capacitance 9 Units 32 channels of single EVP are active 6 8 ICC Max. mA Input Leakage Input Leakage on Pullup Input Leakage on Pulldown O U T P U T S Typ.‡ 10 5 7 Min. IDD_IO IDD_CORE (VDD2 = 1.8 V) Single EV Processor 2 Sym. 0.7VDD1 V 0.3VDD1 IIH/IIL ILU ILD Output High Voltage VOH Output Low Voltage VOL High Impedance Leakage IOZ Output Pin Capacitance CO µA µA µA 10 -100 100 CI V 10 0.8VDD1 VIN=VSS to VDD1or 5.5 V VIN=VSS VIN=VDD1 pF V IOH = 12 mA 0.4 V IOL = 12 mA 10 µA VIN=VSS to 5.5 V 10 pF † Characteristics are over recommended operating conditions unless otherwise stated ‡ Typical figures are at 25°C, VDD1 =3.3 V and are for design aid only: not guaranteed and not subject to production testing. 23 Zarlink Semiconductor Inc. ZL50211 Data Sheet AC Electrical Characteristics† - Timing Parameter Measurement Voltage Levels - Voltages are with respect to ground (Vss) unless otherwise stated. Characteristics Sym. Level Units 1 CMOS Threshold VTT 0.5VDD1 V 2 CMOS Rise/Fall Threshold Voltage High VHM 0.7VDD1 V 3 CMOS Rise/Fall Threshold Voltage Low VLM 0.3VDD1 V Conditions † Characteristics are over recommended operating conditions unless otherwise stated AC Electrical Characteristics† - Frame Pulse and C4i Characteristic 1 Frame pulse width (ST-BUS, GCI) Sym. Min. tFPW 20 Typ.‡ Max. Units 2* ns Notes tCP-20 2 Frame Pulse Setup time before C4i falling (ST-BUS or GCI) tFPS 10 122 150 ns 3 Frame Pulse Hold Time from C4i falling (ST-BUS or GCI) tFPH 10 122 150 ns 4 C4i Period tCP 190 244 300 ns 5 C4i Pulse Width High tCH 85 150 ns 6 C4i Pulse Width Low tCL 85 150 ns 7 C4i Rise/Fall Time tr, tf 10 ns † Characteristics are over recommended operating conditions unless otherwise stated ‡ Typical figures are at 25°C, VDD1 = 3.3 V and for design aid only: not guaranteed and not subject to production testing AC Electrical Characteristics† - Serial Streams for ST-BUS and GCI Backplanes Characteristic Sym. Min. Typ.‡ Max. Units 1 Rin/Sin Set-up Time tSIS 10 ns 2 Rin/Sin Hold Time tSIH 10 ns 3 Rout/Sout Delay - Active to Active tSOD 60 ns 4 Output Data Enable (ODE) Delay tODE 30 ns Test Conditions † Characteristics are over recommended operating conditions unless otherwise stated ‡ Typical figures are at 25°C, VDD1 = 3.3 V and for design aid only: not guaranteed and not subject to production testing AC Electrical Characteristics† - Master Clock - Voltages are with respect to ground (VSS). unless otherwise stated. Characteristic Sym. Min. Typ.‡ Max. Units 1 Master Clock Frequency, - Fsel = 0 - Fsel = 1 fMCF0 fMCF1 19.0 9.5 20.0 10.0 21.0 10.5 MHz MHz 2 Master Clock Low tMCL 20 ns 3 Master Clock High tMCH 20 ns † Characteristics are over recommended operating conditions unless otherwise stated ‡ Typical figures are at 25°C, VDD1 = 3.3 V and for design aid only: not guaranteed and not subject to production testing 24 Zarlink Semiconductor Inc. Notes ZL50211 Data Sheet AC Electrical Characteristics† - Motorola Non-Multiplexed Bus Mode Characteristics Sym. Min. Typ.‡ Max. Units 1 CS setup from DS falling tCSS 0 ns 2 R/W setup from DS falling tRWS 0 ns 3 Address setup from DS falling tADS 0 ns 4 CS hold after DS rising tCSH 0 ns 5 R/W hold after DS rising tRWH 0 ns 6 Address hold after DS rising tADH 0 ns 7 Data delay on read tDDR 8 Data hold on read tDHR 3 9 Data setup on write tDSW 0 ns 10 Data hold on write tDHW 0 ns 11 Acknowledgment delay tAKD 12 Acknowledgment hold time tAKH 13 IRQ delay tIRD 79 ns 15 ns 80 ns 0 8 ns 20 65 ns Test Conditions † Characteristics are over recommended operating conditions unless otherwise stated ‡ Typical figures are at 25°C, VDD1 = 3.3 V and for design aid only: not guaranteed and not subject to production testing tFPW F0i VTT tFPS tCP tFPH tCH tCL tr VHM VTT VLM C4i tSOD Rout/Sout Bit 0, Channel 31 tf Bit 7, Channel 0 tSIS Rin/Sin Bit 0, Channel 31 Bit 6, Channel 0 Bit 5, Channel 0 VTT tSIH Bit 7, Channel 0 Bit 6, Channel 0 Bit 5, Channel 0 Figure 11 - ST-BUS Timing at 2.048 Mb/s 25 Zarlink Semiconductor Inc. VTT ZL50211 Data Sheet tFPW F0i VTT tFPS tCP tFPH tCH tCL tr VHM VTT VLM C4i tSOD Sout/Rout Bit 7, Channel 31 tf Bit 0, Channel 0 tSIS Sin/Rin Bit 1, Channel 0 VTT tSIH Bit 0, Channel 0 Bit 7, Channel 31 Bit 2, Channel 0 Bit 1, Channel 0 Bit 2, Channel 0 VTT Figure 12 - GCI Interface Timing at 2.048 Mb/s VTT ODE tODE tODE Sout/Rout HiZ Valid Data HiZ VTT Figure 13 - Output Driver Enable (ODE) tMCH VTT MCLK tMCL Figure 14 - Master Clock 26 Zarlink Semiconductor Inc. ZL50211 DS Data Sheet tCSS tCSH VTT CS tRWH tRWS VTT R/W tADS tADH VTT VALID ADDRESS A0-A12 tDDR D0-D7 READ VTT tDHR VTT VALID READ DATA tDSW tDHW D0-D7 WRITE VTT VALID WRITE DATA tAKD tAKH VTT DTA tIRD VTT IRQ Figure 15 - Motorola Non-Multiplexed Bus Timing 27 Zarlink Semiconductor Inc. ZL50211 9.0 Data Sheet EVP Registers Description Echo Canceller A (ECA): Control Register 1 Power-up 00hex R/W Address: 00hex + Base Address Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0 Reset INJDis BBM PAD Bypass AdpDis 0 ExtDI Reset Functional Description of Register Bits When high, the power-up initialization is executed. This presets all register bits including this bit and clears the Adaptive Filter coefficients. INJDis When high, the noise injection process is disabled. When low noise injection is enabled. BBM When high, the Back to Back configuration is enabled. When low, the Normal configuration is enabled. Note: Do not enable Extended-Delay and BBM configurations at the same time. Always set both BBM bits of the two echo cancellers (Control Register 1) of the same group to the same logic value to avoid conflict. PAD When high, 12 dB of attenuation is inserted into the Rin to Rout path. When low, the Gains register controls the signal levels. Bypass AdpDis 0 ExtDl When high, Sin data is by-passed to Sout and Rin data is by-passed to Rout. The Adaptive Filter coefficients are set to zero and the filter adaptation is stopped. When low, output data on both Sout and Rout is a function of the echo canceller algorithm. When high, echo canceller adaptation is disabled. The Voice Processor cancels echo. When low, the echo canceller dynamically adapts to the echo path characteristics. Bits marked as “1” or “0” are reserved bits and should be written as indicated. When high, Echo Cancellers A and B of the same group are internally cascaded into one 128 ms echo canceller. When low, Echo Cancellers A and B of the same group operate independently. Echo Canceller B (ECB): Control Register 1 Power-up 02hex R/W Address: 20hex + Base Address Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0 Reset INJDis BBM PAD Bypass AdpDis 1 0 Reset Functional Description of Register Bits When high, the power-up initialization is executed which presets all register bits including this bit and clears the Adaptive Filter coefficients. INJDis When high, the noise injection process is disabled. When low, noise injection is enabled. BBM When high, the Back to Back configuration is enabled. When low, the Normal configuration is enabled. Note: Do not enable Extended-Delay and BBM configurations at the same time. Always set both BBM bits of the two echo cancellers (Control Register 1) of the same group to the same logic value to avoid conflict. PAD When high, 12 dB of attenuation is inserted into the Rin to Rout path. When low, the Gains register controls the signal levels. Bypass AdpDis 1 0 When high, Sin data is by-passed to Sout and Rin data is by-passed to Rout. The Adaptive Filter coefficients are set to zero and the filter adaptation is stopped. When low, output data on both Sout and Rout is a function of the echo canceller algorithm. When high, echo canceller adaptation is disabled. The Voice Processor cancels echo. When low, the echo canceller dynamically adapts to the echo path characteristics. Bits marked as “1” or “0” are reserved bits and should be written as indicated. Control Register 1 (Echo Canceller B) Bit 0 is a reserved bit and should be written “0”. 28 Zarlink Semiconductor Inc. ZL50211 Power-up 00hex Data Sheet ECA: Control Register 2 R/W Address: 01hex + Base Address ECB: Control Register 2 R/W Address: 21hex + Base Address Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0 TDis PHDis NLPDis AutoTD NBDis HPFDis MuteS MuteR Functional Description of Register Bits TDis PHDis When high, tone detection is disabled. When low, tone detection is enabled. When both Echo Cancellers A and B TDis bits are high, Tone Disable processors are disabled entirely and are put into Power Down mode. When high, the tone detectors will trigger upon the presence of a 2100 Hz tone regardless of the presence/absence of periodic phase reversals. When low, the tone detectors will trigger only upon the presence of a 2100 Hz tone with periodic phase reversals. NLPDis When high, the non-linear processor is disabled. When low, the non-linear processors function normally. Useful for G.165 conformance testing. AutoTD When high, the echo canceller puts itself in Bypass mode when the tone detectors detect the presence of 2100 Hz tone. See PHDis for qualification of 2100 Hz tones. When low, the echo canceller algorithm will remain operational regardless of the state of the 2100 Hz tone detectors. NBDis When high, the narrow-band detector is disabled. When low, the narrow-band detector is enabled. When high, the offset nulling high pass filters are bypassed in the Rin and Sin paths. When low, the offset nulling filters are active and will remove DC offsets on PCM input signals. When high, data on Sout is muted to quiet code. When low, Sout carries active code. When high, data on Rout is muted to quiet code. When low, Rout carries active code. HPFDis MuteS MuteR Note: In order to correctly write to Control Register 1 and 2 of ECB, it is necessary to write the data twice to the register, one immediately after another. The two writes must be separated by at least 350 ns and no more than 20 us. 29 Zarlink Semiconductor Inc. ZL50211 Power-up 00hex Data Sheet ECA: Status Register R/W Address: 02hex + Base Address ECB: Status Register R/W Address: 22hex + Base Address Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0 Reserve TD DTDet Reserve Reserve Reserve TDG NB Reserve TD DTDet Functional Description of Register Bits Reserved bit. Logic high indicates the presence of a 2100 Hz tone. Logic high indicates the presence of a double-talk condition. Reserve Reserved bit. Reserve Reserve TDG Reserved bit. Reserved bit. Tone detection status bit gated with the AutoTD bit. (Control Register 2). Logic high indicates that AutoTD has been enabled and the tone detector has detected the presence of a 2100 Hz tone. Logic high indicates the presence of a narrow-band signal on Rin. NB Power-up 00hex ECA: Flat Delay Register (FD) R/W Address: 04hex + Base Address ECB: Flat Delay Register (FD) R/W Address: 24hex + Base Address Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0 FD7 FD6 FD5 FD4 FD3 FD2 FD1 FD0 Power-up 00hex ECA: Decay Step Number Register (NS) R/W Address: 07hex + Base Address ECB: Decay Step Number Register (NS) R/W Address: 27hex+ Base Address Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0 NS7 NS6 NS5 NS4 NS3 NS2 NS1 NS0 Power-up 00hex ECA: Decay Step Size Control Register (SSC) R/W Address: 06hex + Base Address ECB: Decay Step Size Control Register (SSC) R/W Address: 26hex + Base Address Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0 0 0 0 0 0 SSC2 SSC1 SSC0 Note: Bits marked with “0” are reserved bits and should be written “0” 30 Zarlink Semiconductor Inc. ZL50211 Data Sheet Amplitude of MU FIR Filter Length (512 or 1024 taps) 1.0 Step Size (SS) Flat Delay (FD7-0) 2-16 Time Number of Steps (NS7-0) Figure 16 - The MU Profile Functional Description of Register Bits The Exponential Decay registers (Decay Step Number and Decay Step Size) and Flat Delay register allow the LMS adaptation step-size (MU) to be programmed over the length of the FIR filter. A programmable MU profile allows the performance of the echo canceller to be optimized for specific applications. For example, if the characteristic of the echo response is known to have a flat delay of several milliseconds and a roughly exponential decay of the echo impulse response, then the MU profile can be programmed to approximate this expected impulse response thereby improving the convergence characteristics of the Adaptive Filter. Note that in the following register descriptions, one tap is equivalent to 125 µs (64 ms/512 taps). FD7-0 Flat Delay: This register defines the flat delay of the MU profile, (i.e., where the MU value is 2-16). The delay is defined as FD7-0 x 8 taps. For example; If FD7-0 = 5, then MU=2-16 for the first 40 taps of the echo canceller FIR filter. The valid range of FD7-0 is: 0 ≤ FD7-0 ≤ 64 in normal mode and 0 ≤ FD7-0 ≤ 128 in extended-delay mode. The default value of FD7-0 is zero. SSC2-0 Decay Step Size Control: This register controls the step size (SS) to be used during the exponential decay of MU. The decay rate is defined as a decrease of MU by a factor of 2 every SS taps of the FIR filter, where SS = 4 x2SSC2-0. For example; If SSC2-0 = 4, then MU is reduced by a factor of 2 every 64 taps of the FIR filter. The default value of SSC2-0 is 04hex. NS7-0 Decay Step Number: This register defines the number of steps to be used for the decay of MU where each step has a period of SS taps (see SSC2-0). The start of the exponential decay is defined as: Filter Length (512 or 1024) - [Decay Step Number (NS7-0) x Step Size (SS)] where SS = 4 x2SSC2-0. For example; If NS7-0=4 and SSC2-0=4, then the exponential decay start value is 512 - [NS7-0 x SS] = 512 - [4 x (4x24)] = 256 taps for a filter length of 512 taps. 31 Zarlink Semiconductor Inc. ZL50211 Power-up FBhex Data Sheet ECA: Control Register 3 R/W Address: 08hex + Base Address ECB: Control Register 3 R/W Address: 28hex + Base Address Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0 NLRun2 InjCtrl NLRun1 RingClr Reserve PathClr PathDet NLPSel NLRun2 InjCtrl NLRun1 Functional Description of Register Bits When high, the comfort noise level estimator actively rejects double-talk as being background noise. When low, the noise level estimator makes no such distinction. Selects which noise ramping scheme is used. See Table below. When high, the comfort noise level estimator actively rejects uncancelled echo as being background noise. When low, the noise level estimator makes no such distinction. RingClr When high, the instability detector is activated. When low, the instability detector is disabled. Reserve PathClr Reserved bit. Must always be set to one for normal operation. When high, the current echo channel estimate will be cleared and the echo canceller will enter fast convergence mode upon detection of a path change. When low, the echo canceller will keep the current path estimate but revert to fast convergence mode upon detection of a path change. Note: this bit is ignored if PathDet is low. When high, the path change detector is activated. When low, the path change detector is disabled. When high, the Advanced NLP is selected. When low, the original NLP is selected. PathDet NLPSel Table 5 below is the same Table shown on page 9. Feature Register or Bit(s) Advanced NLP Default Value Original NLP Default Value NLP Selection NLPSel (Control Register 3) 1 0 (feature not supported) Reject uncancelled echo as noise NLRun1 (Control Register 3) 1 0 (feature not supported) Reject double-talk as noise NLRun2 (Control Register 3) 1 0 (feature not supported) Noise level estimator ramping scheme InjCtrl (Control Register 3) 1 0 (feature not supported) Noise level ramping rate NLInc (Noise Control) 5hex Chex Noise level scaling Noise Scaling 16hex 74hex Table 5 - Comparison of the NLP Types 32 Zarlink Semiconductor Inc. ZL50211 Power-up 54hex Data Sheet ECA: Control Register 4 R/W Address: 09hex + Base Address ECB: Control Register 4 R/W Address: 29hex + Base Address Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0 0 SD2 SD1 SD0 0 Slow2 Slow1 Slow0 0 SupDec 0 Slow Functional Description of Register Bits Must be set to zero. These three bits (SD2,SD1,SD0) control how long the echo canceller remains in a fast convergence state following a path change, Reset or Bypass operation. A value of zero will keep the echo canceller in fast convergence indefinitely. Must be set to zero. Slow convergence mode speed adjustment.(Bits Slow2, Slow1,Slow0) For Slow = 1, 2,..., 7, slow convergence speed is reduced by a factor of 2Slow as compared to normal adaptation. For Slow = 0, no adaptation occurs during slow convergence. Power-up 16hex ECA: Noise Scaling (NS) R/W Address: 0Ahex + Base Address ECB: Noise Scaling (NS) R/W Address: 2Ahex + Base Address Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0 NS7 NS6 NS5 NS4 NS3 NS2 NS1 NS0 Functional Description of Register Bits This register is used to scale the comfort noise up or down. Larger values will increase the relative level of comfort noise. The default value of 16hex will provide G.168 compliance with the Advanced NLP. A value of 74hex is recommended if the original NLP is used. Power-up 45hex ECA: Noise Control R/W Address: 0Bhex + Base Address ECB: Noise Control R/W Address: 2Bhex + Base Address Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0 Reserve Reserve Reserve Reserve NLInc3 NLInc2 NLInc1 NLInc0 Reserve NLInc Functional Description of Register Bits Reserved bits. Must be set to 4hex for normal operation. Noise level estimator ramping rate. When InjCtrl = 1, a lower value will give faster ramping. When InjCtrl = 0, a higher value will give faster ramping. The default value of 5hex will provide G.168 compliance with InjCtrl = 1. A value of Chex is recommended if InjCtrl = 0. 33 Zarlink Semiconductor Inc. ZL50211 Power-up N/A Data Sheet ECA: Rin Peak Detect Register 2 (RP) R/W Address: 0Dhex + Base Address ECB: Rin Peak Detect Register 2 (RP) R/W Address: 2Dhex + Base Address Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0 RP15 RP14 RP13 RP12 RP11 RP10 RP9 RP8 Power-up N/A ECA: Rin Peak Detect Register 1 (RP) ECB: Rin Peak Detect Register 1 (RP) Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 RP7 RP6 RP5 RP4 RP3 RP2 R/W Address: 0Chex + Base Address R/W Address: 2Chex + Base Address Bit 1 Bit 0 RP1 RP0 Functional Description of Register Bits These peak detector registers allow the user to monitor the receive in (Rin) peak signal level. The information is in 16-bit 2’s complement linear coded format presented in two 8 bit registers for each echo canceller. The high byte is in Register 2 and the low byte is in Register 1. Power-up N/A Bit 7 SP15 Bit 6 SP14 Power-up N/A ECA: Sin Peak Detect Register 2 (SP) R/W Address: 0Fhex + Base Address ECB: Sin Peak Detect Register 2 (SP) R/W Address: 2Fhex + Base Address Bit 5 SP13 Bit 4 SP12 Bit 3 SP11 Bit 2 SP10 ECA: Sin Peak Detect Register 1 (SP) ECB: Sin Peak Detect Register 1 (SP) Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 SP7 SP6 SP5 SP4 SP3 SP2 Bit 1 SP9 Bit 0 SP8 R/W Address: 0Ehex + Base Address R/W Address: 2Ehex + Base Address Bit 1 Bit 0 SP1 SP0 Functional Description of Register Bits These peak detector registers allow the user to monitor the send in (Sin) peak signal level. The information is in 16-bit 2’s complement linear coded format presented in two 8 bit registers for each echo canceller. The high byte is in Register 2 and the low byte is in Register 1. 34 Zarlink Semiconductor Inc. ZL50211 Power-up N/A Data Sheet ECA: Error Peak Detect Register 2 (EP) R/W Address: 11hex + Base Address ECB: Error Peak Detect Register 2 (EP) R/W Address: 31hex + Base Address Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0 EP15 EP14 EP13 EP12 EP11 EP10 EP9 EP8 Power-up N/A ECA: Error Peak Detect Register 1 (EP) R/W Address: 10hex + Base Address ECB: Error Peak Detect Register 1 (EP) R/W Address: 30hex + Base Address Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0 EP7 EP6 EP5 EP4 EP3 EP2 EP1 EP0 Functional Description of Register Bits These peak detector registers allow the user to monitor the error signal peak level. The information is in 16-bit 2’s complement linear coded format presented in two 8 bit registers for each echo canceller. The high byte is in Register 2 and the low byte is in Register 1. Power-up 48hex ECA: Double-Talk Detection Threshold Register 2 R/W Address: 15hex + Base Address ECB: Double-Talk Detection Threshold Register 2 R/W Address: 35hex + Base Address Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0 DTDT15 DTDT14 DTDT13 DTDT12 DTDT11 DTDT10 DTDT9 DTDT8 Power-up 00hex ECA: Double-Talk Detection Threshold Register 1 R/W Address: 14hex + Base Address ECB: Double-Talk Detection Threshold Register 1 R/W Address: 34hex + Base Address Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0 DTDT7 DTDT6 DTDT5 DTDT4 DTDT3 DTDT2 DTDT1 DTDT0 Functional Description of Register Bits This register allows the user to program the level of Double-Talk Detection Threshold (DTDT). The 16 bit 2’s complement linear value defaults to 4800hex= 0.5625 or -5 dB. The maximum value is 7FFFhex = 0.9999 or 0 dB. The high byte is in Register 2 and the low byte is in Register 1. 35 Zarlink Semiconductor Inc. ZL50211 Power-up 0Chex Data Sheet ECA: Non-Linear Processor Threshold Register 2 (NLPTHR) R/W Address: 19hex + Base Address ECB: Non-Linear Processor Threshold Register 2 (NLPTHR) R/W Address: 39hex + Base Address Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0 NLP15 NLP14 NLP13 NLP12 NLP11 NLP10 NLP9 NLP8 Power-up E0hex ECA: Non-Linear Processor Threshold Register 1 (NLPTHR) R/W Address: 18hex + Base Address ECB: Non-Linear Processor Threshold Register 1 (NLPTHR) R/W Address: 38hex + Base Address Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0 NLP7 NLP6 NLP5 NLP4 NLP3 NLP2 NLP1 NLP0 Functional Description of Register Bits This register allows the user to program the level of the Non-Linear Processor Threshold (NLPTHR). The 16 bit 2’s complement linear value defaults to 0CE0hex = 0.1 or -20.0 dB. The maximum value is 7FFFhex = 0.9999 or 0 dB. The high byte is in Register 2 and the low byte is in Register 1. Power-up 40hex ECA: Adaptation Step Size Register 2 (MU) R/W Address: 1Bhex + Base Address ECB: Adaptation Step Size Register 2 (MU) R/W Address: 3Bhex + Base Address Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0 MU15 MU14 MU13 MU12 MU11 MU10 MU9 MU8 Power-up 00hex ECA: Adaptation Step Size Register 1 (MU) ECB: Adaptation Step Size Register 1 (MU) R/W Address: 1Ahex + Base Address R/W Address: 3Ahex + Base Address Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0 MU7 MU6 MU5 MU4 MU3 MU2 MU1 MU0 Functional Description of Register Bits This register allows the user to program the level of MU. MU is a 16 bit 2’s complement value which defaults to 4000hex = 1.0 The maximum value is 7FFFhex or 1.9999 decimal. The high byte is in Register 2 and the low byte is in Register 1. 36 Zarlink Semiconductor Inc. ZL50211 Power-up 44hex Data Sheet ECA: Gains Register 2 R/W Address: 1Dhex + Base Address ECB: Gains Register 2 R/W Address: 3Dhex + Base Address Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0 0 Rin2 Rin1 Rin0 0 Rout2 Rout1 Rout0 Power-up 44hex ECA: Gains Register 1 R/W Address: 1Chex + Base Address ECB: Gains Register 1 R/W Address: 3Chex + Base Address Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0 0 Sin2 Sin1 Sin0 0 Sout2 Sout1 Sout0 Functional Description of Register Bits This register is used to select gain values on RIN, ROUT, SIN and SOUT. Gains has the following structure: RIN ROUT SIN SOUT Gains = 0xxx 0xxx 0xxx 0xxx = 0100 0100 0100 0100 (4444hex) default Gains is split into four groups of four bits. Each group maps to a different signal port (as indicated above), and has three gain bits. The following table indicates how these gain bits are used: Bit2 1 0 0 0 0 Bit1 Bit0 0 0 1 1 1 0 0 1 0 0 Gain Level 0 dB (default) -3 dB -6 dB -9 dB -12 dB Note that the -12 dB PAD bit in Control Register 1 provides 12 dB of attenuation in the Rin to Rout path, and will override the settings in Gains. 37 Zarlink Semiconductor Inc. ZL50211 Data Sheet Main Control Register 0 (EC Group 0) R/W Address: 400hex Power-up 00hex Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0 WR_all ODE MIRQ MTDBI MTDAI Format Law PWUP WR_all ODE MIRQ Functional Description of Register Bits Write all control bit: When high, Group 0-15 Echo Cancellers Registers are mapped into 0000hex to 0003Fhex which is Group 0 address mapping. Useful to initialize the 16 Groups of Echo Cancellers as per Group 0. When low, address mapping is per Figure 10. Note: Only the Main Control Register 0 has the WR_all bit Output Data Enable: This control bit is logically AND’d with the ODE input pin. When both ODE bit and ODE input pin are high, the Rout and Sout outputs are enabled. When the ODE bit is low or the ODE input pin is low, the Rout and Sout outputs are high impedance. Note: Only the Main Control Register 0 has the ODE bit. Mask Interrupt: When high, all the interrupts from the Tone Detectors output are masked. The Tone Detectors operate as specified in their Echo Canceller B, Control Register 2. When low, the Tone Detectors Interrupts are active. Note: Only the Main Control Register 0 has the MIRQ bit. MTDBI Mask Tone Detector B Interrupt: When high, the Tone Detector interrupt output from Echo Canceller B is masked. The Tone Detector operates as specified in Echo Canceller B, Control Register 2. When low, the Tone Detector B Interrupt is active. MTDAI Mask Tone Detector A Interrupt: When high, the Tone Detector interrupt output from Echo Canceller A is masked. The Tone Detector operates as specified in Echo Canceller A, Control Register 2. When low, the Tone Detector A Interrupt is active. Format ITU-T/Sign Mag: When high, both Echo Cancellers A and B for a given group, accept ITU-T (G.711) PCM code. When low, both Echo Cancellers A and B for a given group, accept signmagnitude PCM code. Law PWUP A/µ Law: When high, both Echo Cancellers A and B for a given group, accept A-Law companded PCM code. When low, both Echo Cancellers A and B for a given group, accept µ-Law companded PCM code. Power-UP: When high, both Echo Cancellers A and B and Tone Detectors for a given group, are active. When low, both Echo Cancellers A and B and Tone Detectors for a given group, are placed in Power Down mode. In this mode, the corresponding PCM data are bypassed from Rin to Rout and from Sin to Sout with two frames delay. When the PWUP bit toggles from zero to one, the echo canceller A and B execute their initialization routine which presets their registers, Base Address+00hex to Base Address+3Fhex, to the default power up value and clears the Adaptive Filter coefficients. Two frames are necessary for the initialization routine to execute properly. Once the initialization routine is executed, the user can set the per channel Control Registers for their specific application. 38 Zarlink Semiconductor Inc. ZL50211 Data Sheet Main Control Register 1 (EC Group 1) R/W Address: 401hex Main Control Register 2 (EC Group 2) R/W Address: 402hex Main Control Register 3 (EC Group 3) R/W Address: 403hex Main Control Register 4 (EC Group 4) R/W Address: 404hex Main Control Register 5 (EC Group 5) R/W Address: 405hex Main Control Register 6 (EC Group 6) R/W Address: 406hex Main Control Register 7 (EC Group 7) R/W Address: 407hex Main Control Register 8 (EC Group 8) R/W Address: 408hex Main Control Register 9 (EC Group 9) R/W Address: 409hex Main Control Register 10 (EC Group 10) R/W Address: 40Ahex Main Control Register 11 (EC Group 11) R/W Address: 40Bhex Main Control Register 12 (EC Group 12) R/W Address: 40Chex Main Control Register 13 (EC Group 13) R/W Address: 40Dhex Main Control Register 14 (EC Group 14) R/W Address: 40Ehex Main Control Register 15 (EC Group 15) R/W Address: 40Fhex Power-up 00hex Bit 7 Unused Unused MTDBI MTDAI Format Law PWUP Bit 6 Unused Bit 5 Unused Bit 4 Bit 3 MTDBI MTDAI Bit 2 Format Bit 1 Law Bit 0 PWUP Functional Description of Register Bits Unused Bits. Mask Tone Detector B Interrupt: When high, the Tone Detector interrupt output from Echo Canceller B is masked. The Tone Detector operates as specified in Echo Canceller B, Control Register 2. When low, the Tone Detector B Interrupt is active. Mask Tone Detector A Interrupt: When high, the Tone Detector interrupt output from Echo Canceller A is masked. The Tone Detector operates as specified in Echo Canceller A, Control Register 2. When low, the Tone Detector A Interrupt is active. ITU-T/Sign Mag: When high, both Echo Cancellers A and B for a given group, select ITU-T (G.711) PCM code. When low, both Echo Cancellers A and B for a given group, select sign-magnitude PCM code. A/µ Law: When high, both Echo Cancellers A and B for a given group, select A-Law companded PCM code. When low, both Echo Cancellers A and B for a given group, select µ-Law companded PCM code. Power-UP: When high, both Echo Cancellers A and B and Tone Detectors for a given group, are active. When low, both Echo Cancellers A and B and Tone Detectors for a given group, are placed in Power Down mode. In this mode, the corresponding PCM data are bypassed from Rin to Rout and from Sin to Sout with two frames delay. When the PWUP bit toggles from zero to one, the echo cancellers A and B execute their initialization routine which presets their registers, Base Address+00hex to Base Address+3Fhex, to the default Reset Value and clears the Adaptive Filter coefficients. Two frames are necessary for the initialization routine to execute properly. Once the initialization routine is executed, the user can set the per channel Control Registers for their specific application. 39 Zarlink Semiconductor Inc. ZL50211 Data Sheet Interrupt FIFO Register R/W Address: 410hex Power-up 00hex Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0 IRQ 0 0 I4 I3 I2 I1 I0 IRQ 0 0 I<4:0> Functional Description of Register Bits Logic high indicates an interrupt has occurred. IRQ bit is cleared after the Interrupt FIFO register is read. Logic Low indicates that no interrupt is pending and the FIFO is empty. Unused bit. Always zero. Unused bit. Always zero. I<4:0> binary code indicates the channel number at which a Tone Detector state change has occurred. Note: Whenever a Tone Disable is detected or released, an interrupt is generated. Test Register Power-up 00hex R/W Address: 411hex Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0 Reserve Reserve Reserve Reserve Reserve Reserve Reserve Tirq Reserve Tirq Functional Description of Register Bits Reserved bits. Must always be set to zero for normal operation. Test IRQ: Useful for the application engineer to verify the interrupt service routine. When high, any change to MTDBI and MTDAI bits of the Main Control Register will cause an interrupt and its corresponding channel number will be available from the Interrupt FIFO Register. When low, normal operation is selected. 40 Zarlink Semiconductor Inc. For more information about all Zarlink products visit our Web Site at www.zarlink.com Information relating to products and services furnished herein by Zarlink Semiconductor Inc. or its subsidiaries (collectively “Zarlink”) is believed to be reliable. However, Zarlink assumes no liability for errors that may appear in this publication, or for liability otherwise arising from the application or use of any such information, product or service or for any infringement of patents or other intellectual property rights owned by third parties which may result from such application or use. Neither the supply of such information or purchase of product or service conveys any license, either express or implied, under patents or other intellectual property rights owned by Zarlink or licensed from third parties by Zarlink, whatsoever. Purchasers of products are also hereby notified that the use of product in certain ways or in combination with Zarlink, or non-Zarlink furnished goods or services may infringe patents or other intellectual property rights owned by Zarlink. This publication is issued to provide information only and (unless agreed by Zarlink in writing) may not be used, applied or reproduced for any purpose nor form part of any order or contract nor to be regarded as a representation relating to the products or services concerned. The products, their specifications, services and other information appearing in this publication are subject to change by Zarlink without notice. No warranty or guarantee express or implied is made regarding the capability, performance or suitability of any product or service. Information concerning possible methods of use is provided as a guide only and does not constitute any guarantee that such methods of use will be satisfactory in a specific piece of equipment. It is the user’s responsibility to fully determine the performance and suitability of any equipment using such information and to ensure that any publication or data used is up to date and has not been superseded. Manufacturing does not necessarily include testing of all functions or parameters. These products are not suitable for use in any medical products whose failure to perform may result in significant injury or death to the user. All products and materials are sold and services provided subject to Zarlink’s conditions of sale which are available on request. Purchase of Zarlink’s I2C components conveys a licence under the Philips I2C Patent rights to use these components in and I2C System, provided that the system conforms to the I2C Standard Specification as defined by Philips. Zarlink, ZL and the Zarlink Semiconductor logo are trademarks of Zarlink Semiconductor Inc. Copyright Zarlink Semiconductor Inc. All Rights Reserved. TECHNICAL DOCUMENTATION - NOT FOR RESALE