General Purpose Relays Power PCB Relay RT1 Inrush Power I 1 pole 16 A, 1 NO contact (W pre-make contact + AgSnO2) I 10 A / 250 VAC making and breaking capacity acc. to IEC 60669-1 I 165 A / 20 ms inrush peak current I Mono- or bistable coil I 5 kV / 10 mm coil-contact I Reinforced insulation I Optional test tab (manual operator) I RoHS compliant (Directive 2002/95/EC) Applications Lighting systems, movement sensors, filament and incandescent lamp loads, motors F0272-A Approvals V REG.-Nr. 6106, Z E214025 Technical data of approved types on request Contact data RT.3T RTS3L Contact configuration 1 NO Contact set pre-make contact single contact Type of interruption micro disconnection Rated current 16 A Rated voltage / max.switching voltage AC 250/400 VAC Limiting continuous current 16 A Maximum breaking capacity AC 4000 VA Limiting making capacity max 20 ms (incandescent lamps) 165 A 120 A max 200 μs (fluorescent lamps) 800 A Contact material W (pre-make cont.)+AgSnO2 AgSnO2 Mechanical endurance DC > 5x106 cycles > 10x106 cycles bistable > 3x106 cycles > 5x106 cycles tab manually operated > 103 cycles Rated frequency of operation with / without load 6 / 60 min-1 Contact Type RTS3T RT*3T RT*3T RTS3L RTS3L RTS3L RTS3L ratings Load 3000 W, 230 VAC, DF 8,3%, 5 min-1, incandescent lamp 16 A, 250 VAC, capacitive load 140 μF, 7,5 min-1, EN60669-1 TV5, UL508, 40°C 16 A, 250 VAC, 85°C 1.5 hp, 240 VAC TV8, UL508, 40°C 10/100 A / 250 VAC, simulated lamp load, acc. to IEC 61810-2 Cycles typ. 12x103 > 20x103 25x103 > 100x103 25x103 20x103 Coil data Coil data, monostable coil Rated coil voltage range Coil power Operative range Coil insulation system according UL1446 5...110 VDC typ 400 mW 2 class F Coil versions, monostable DC-coil Coil Rated Operate Release Coil Rated coil code voltage voltage voltage resistance power VDC VDC VDC c mW 005 5 3.5 0.5 62+10% 403 006 6 4.2 0.6 90+10% 400 012 12 8.4 1.2 360+10% 400 024 24 16.8 2.4 1440+10% 400 048 48 33.6 4.8 5520+10% 417 060 60 42.0 6.0 8570+12% 420 110 110 77.0 11.0 28800+12% 420 All figures are given for coil without preenergization, at ambient temperature +23°C Other coil voltages on request 1 Datasheet Rev. EK1 Issued 2005/11 www.tycoelectronics.com www.schrackrelays.com Dimensions are in mm unless otherwise specified and are shown for reference purposes only. Product specification according to IEC 61810-1. Product data, technical parameters, test conditions and processing information only to be used together with the 'Definitions' at schrackrelays.com in the ‘Schrack’ section. Specifications subject to change. General Purpose Relays Power PCB Relay RT1 Inrush Power (Continued) Coil data, bistable coils Rated coil voltage range Coil power Operative range Limiting voltage, % of rated coil voltage Minimum energization duration Maximum energization duration Coil insulation system according UL1446 1 coil 2 coils 3...24 VDC typ 400 mW typ 600 mW 2 120% 150% 30 ms 1 min at < 10% DF class F Coil versions, bistable 1 coil Coil Rated Operate Reset Coil Rated coil code voltage voltage voltage resistance power VDC VDC VDC c mW A03 3 2.1 2.1 21+10% 429 A12 12 8.4 8.4 360+10% 400 A24 24 16.8 16.8 1440+10% 400 Coil versions, bistable 2 coils F03 3 2.1 2.1 15+10% 600 F12 12 8.4 8.4 240+10% 600 F24 24 16.8 16.8 886+10% 650 All figures are given for coil without preenergization, at ambient temperature +23°C Other coil voltages on request Coils - operation Version Coil terminals Pull-in Reset Contact position not defined at delivery 1 coil A1 A2 + + A1 - 2 coils A3 + + A2 - Insulation Dielectric strength coil-contact circuit open contact circuit Clearance / creepage coil-contact circuit Material group of insulation parts Tracking index of relay base Insulation to IEC 60664-1 Type of insulation coil-contact circuit open contact circuit Rated insulation voltage Pollution degree Rated voltage system Overvoltage category 4000 Vrms 1250 Vrms W 10 / 10 mm W IIIa PTI 250 V Bottom view on solder pins reinforced functional 250 V 3 240 V monostable version 2 400 V III Other data RT.3T RoHS - Directive 2002/95/EC Flammability class according to UL94 Ambient temperature range Vibration resistance (function) monostable Shock resistance (destruction) Category of protection Mounting Mounting distance Resistance to soldering heat Relay weight with / without test tab Packaging unit with / without test tab Terminal assignment RTS3L compliant V-0 -40...70°C 10 g S0163-BF -40...85°C 20 g 100 g RTII - flux proof pcb pcb or on socket 0 mm 270 °C / 10 s 16 / 14 g - / 14 g 100 / 500 pcs - / 500 pcs bistable version a) S0163-CS Accessories RTS3L For details see datasheet Accessories Power Relay RT a) Indicated contact position during or after coil energization with reset voltage. b) for 2 coil version only 2 Datasheet Rev. EK1 Issued 2005/11 www.tycoelectronics.com www.schrackrelays.com Dimensions are in mm unless otherwise specified and are shown for reference purposes only. Product specification according to IEC 61810-1. Product data, technical parameters, test conditions and processing information only to be used together with the 'Definitions' at schrackrelays.com in the ‘Schrack’ section. Specifications subject to change. General Purpose Relays Power PCB Relay RT1 Inrush Power (Continued) Dimensions / PCB layout version without test tab 16 A, pinning 5 mm s0418-CV S0272-BW b) for 2 coil version only S0272-BC version with test tab *) With the recommended PCB hole sizes a grid pattern from 2.5 mm to 2.54 mm can be used. S0491-B S0492-CU Product key Type Version S without test tab R T T Contact configuration 3 1 NO contact Contact material T L AgSnO2 Coil Coil code: please refer to coil versions table 3 with test tab (manual operator) for contact material ‘T’ only Tungsten (W) pre-make + AgSnO2 3 Datasheet Rev. EK1 Issued 2005/11 www.tycoelectronics.com www.schrackrelays.com Dimensions are in mm unless otherwise specified and are shown for reference purposes only. Product specification according to IEC 61810-1. Product data, technical parameters, test conditions and processing information only to be used together with the 'Definitions' at schrackrelays.com in the ‘Schrack’ section. Specifications subject to change. General Purpose Relays Power PCB Relay RT1 Inrush Power (Continued) Product key RTS3L005 RTS3L012 RTS3L018 RTS3L024 RTS3L048 RTS3L060 RTS3LA12 RTS3LA24 RTS3LF12 RTS3LF24 RTS3T012 RTS3T024 RTS3TA12 RTS3TA24 RTS3TF03 RTS3TF12 RTS3TF24 RTT3TA12 RTT3TA24 RTT3TF12 RTT3TF24 Version without test tab Contacts 1 NO contact Cont. material AgSnO2 W pre-make + AgSnO2 with test tab Coil monostable coil bistable 1-coil bistable 2-coils monostable coil bistable 1-coil bistable 2-coils bistable 1-coil bistable 2-coils Coil 5 VDC 12 VDC 18 VDC 24 VDC 48 VDC 60 VDC 12 VDC 24 VDC 12 VDC 24 VDC 12 VDC 24 VDC 12 VDC 24 VDC 3 VDC 12 VDC 24 VDC 12 VDC 24 VDC 12 VDC 24 VDC Part number 1-1415898-8 1-1415898-9 2-1415898-0 1-1415898-4 2-1415898-1 2-1415898-2 2-1415898-3 2-1415898-4 2-1415898-5 2-1415898-6 0-1415898-0 0-1415898-1 0-1415898-2 0-1415898-3 0-1415898-4 0-1415898-5 0-1415898-6 0-1415898-7 0-1415898-8 0-1415898-9 1-1415898-0 4 Datasheet Rev. EK1 Issued 2005/11 www.tycoelectronics.com www.schrackrelays.com Dimensions are in mm unless otherwise specified and are shown for reference purposes only. Product specification according to IEC 61810-1. Product data, technical parameters, test conditions and processing information only to be used together with the 'Definitions' at schrackrelays.com in the ‘Schrack’ section. Specifications subject to change.